Attachment 15 - WADOT Aluminum Pedestrian Rail Details.pdf

PDF 103 KB Posted

Attached to
Repairs to McChord Bridge – Barnes Blvd
Solicitation number
W912DW24B0Y1Y
Issued by

About this file

This document contains details for a federal solicitation and related federal contract opportunity. The solicitation W912DW24B0Y1Y is an Invitation for Bid for repairs to the Barnes Boulevard Bridge on Joint Base Lewis-McChord in Washington. The contractor shall provide all labor, equipment, materials, tools and transportation to perform tasks within the statement of work. This is a 100% small business set-aside restricted to 8(a) firms, with a NAICS code of 237310 and size standard of $45 million. The estimated value of the construction contract is between $7.5 million and $15 million. The attached file provides aluminum pedestrian rail details relevant to the bridge repairs.

View the file

Other files

File Type Posted
OF1419 Abstract of Bids for Barnes Blvd. Bridge Repairs (Signed).pdf PDF
Attachment 19 - Replacement Drawing TO-02 TELECOM SITE PLAN in Attachment 2.pdf PDF
W912DW24B0Y1Y - Amendment 0006.pdf PDF
Attachment 18 - Replacement Drawing TO-01 TELECOM LEGEND in Attachment 2.pdf PDF
W912DW24B0Y1Y Amendment 0004.pdf PDF
Attachment 14 - Replacement Drawing CU102 NEC Profile Details in Attachment 2 (Rev 1).pdf PDF
W912DW24B0Y1Y - Repair Barnes Blvd. - IFB Amendment 0006.pdf PDF
W912DW24B0Y1Y Amendment 0003.pdf PDF
W912DW24B0Y1Y Amendment 0002.pdf PDF
Attachment 20 - Replacement Drawing CU101 UTILITIES PLAN in Attachment 2.pdf PDF
W912DW24B0Y1Y Amendment 0001.pdf PDF
Attachment 7 - Barnes Blvd Temporary Bridge Detour Requirements and Details (Rev 1).pdf PDF
Attachment 1 - SPECIFICATIONS Revised Barnes Blvd Bridge McChord IFC 2024-03-15.pdf PDF
W912DW24B0Y1Y - Repair Barnes Blvd. - IFB Amendment 0005.pdf PDF
W912DW24B0Y1Y Amendment 0005.pdf PDF
Attachment 1 - SPECIFICATIONS Revised Barnes Blvd Bridge McChord IFC 2024-03-06.pdf PDF
W912DW24B0Y1Y Amendment 0004.pdf PDF
Attachment 16 - Replacement Drawing S 135 Utility Bridge Typical Section in Attachment 2 (Rev 1).pdf PDF
Attachment 17 - Replacement Drawing S-132 Pedestrian Rail Detail 1 in Attachment 2 (Rev 1).pdf PDF
W912DW24B0Y1Y - Repair Barnes Blvd - IFB Amendment 0004.pdf PDF
W912DW24B0Y1Y - Repair Barnes Blvd - IFB Amendment 0003.pdf PDF
W912DW24B0Y1Y Amendment 0003.pdf PDF
Attachment 17 - Replacement Drawing S-132 Pedestrian Rail Detail 1 in Attachment 2.pdf PDF
Attachment 16 - Replacement Drawing S-135 Utility Bridge Typical Section in Attachment 2.pdf PDF
W912DW24B0Y1Y Amendment 0002.pdf PDF
Attachment 1 - SPECIFICATIONS Revised Barnes Blvd Bridge McChord IFC 2024-02-21.pdf PDF
W912DW24B0Y1Y - Repair Barnes Blvd - IFB Amendment 0002.pdf PDF
Site Visit Sign-In Sheet - Repair Barnes Bridge.pdf PDF
Attachment 14 - Replacement Drawing CU102 NEC ProfileDetails in Attachment 2.pdf PDF
Attachment 10 - Utility Contacts Fees Responsiblities (Rev 01).pdf PDF
W912DW24B0Y1Y Amendment 0001.pdf PDF
W912DW24B0Y1Y - Repair Barnes Blvd - IFB Amendment 0001.pdf PDF
Attachment 1 - SPECIFICATIONS Revised Barnes Blvd Bridge McChord IFC 2024-02-09.pdf PDF
Attachment 3 - 2023-11-14 McChord Field Bridges Stormwater Drainage Plan (Rev 1).pdf PDF
Attachment 1 - SPECIFICATIONS Revised Barnes Blvd Bridge McChord IFC.pdf PDF
Attachment 5 - Stream Work to follow Nationwide USACE Permit 2021-NWP14-Enclosure-20220511.pdf PDF
Attachment 2 - 2023-11-17 100 Series - IFC Plans 11x17 (Rev 01).pdf PDF
Attachment 10 - Utility Contacts Fees Responsiblities.pdf PDF
Submittal Register - Barnes Blvd. Bridge Repairs.xlsx XLSX spreadsheet
Attachment 4 - 2021-12-22 McChord Geotech Bridge Foundation Report.pdf PDF
Attachment 13 - Revised PSE Utility Drawings.pdf PDF
Attachment 7 - Barnes Blvd Temporary Bridge Detour Requirements and Details.pdf PDF
Attachment 12 - FAA Form 7460-1 052026.pdf PDF
Attachment 11 - Draft Property Barnes Blvd 2021-10-12 Form DD 1354.pdf PDF
JA Brand Name - Repair Barnes Blvd Redacted.pdf PDF
W912DW24B0Y1Y - Repair Barnes Blvd - IFB.pdf PDF
Attachment 9 - 2021-11-11 McChord H-H Analysis Report.pdf PDF
Attachment 8 - Temp Stockpile Lining Diagram.pdf PDF
Attachment 6 - Standard Operating Procedures for use of Grays Army Airfield Borrow Source Pit.pdf PDF
Show all 49

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Bridge Design Engr.

Supervisor

Designed By

Checked By

Detailed By

Bridge Projects Engr.

Prelim. Plan By

Architect/Specialist REVISION BY APP'DDATE

FED. AID PROJ. NO.STATE

10 WASH.

JOB NUMBER

Fri Aug 07 12:57:00 2020

.5

-A -1

M:\STANDARDS\BP Rails\4ftPedRail_Alumin 1.MAN

03/31/2020

¢ POST ¢ POST¢ POST¢ END POST

6'-8"6"

7½" 10 SPA. @ 6½" = 5'-5" 7½"

12 SPA. @ 7" MAX. = 7'-0"

C

BR2

SEE DETAIL 1

BR2

RAIL (2½"ø

SCH. 40 PIPE)

POST (TYP.)

(2½"ø SCH. 80 PIPE.)

TOP OF

SIDEWALKDUMMY JOINT (TYPICAL AT

EACH RAIL POST LOCATION)

BALUSTER (TYP.)

(1"ø SCH. 40 PIPE)

END OF APPROACH FOR BRIDGE OR

END OF CONC. ON RETAINING WALLS

ELEVATION

BALUSTERS NORMAL TO GRADE.

TOP & BOTTOM RAILS PARALLEL TO GRADE.

* NOTE TO DESIGNER:

Designer to choose color for their project in consultation with the Bridge Architect.

MATERIAL

SPECIFICATION

PART

M A T 'L

ASTM B221-6005-T5, 6005A-T5

OR ASTM B241-6061-T6

STANDARD SPECIFICATION SECTION

9-06.5(4) GR. 36

(GALVANIZE IN ACCORDANCE WITH AASHTO

SPECIFICATION M 232)

ASTM A276 OR A240 TYPE 302 STAINLESS STEEL

RAILS &

BALUSTERS

DRIVE PINS

ANCHOR BOLTS,

NUTS & WASHERS

A

LU

M

IN

U M

S T E E L

ASTM B221-6005-T5STRIP

1.

2.

3.

4.

5.

6.

PIPE RAILING AND PIPE RAILING SPLICES SHALL BE BENT TO THE HORIZONTAL

CURVE WHERE THE RADIUS OF CURVATURE IS LESS THAN 200'. THESE ITEMS

MAY BE HEATED TO NOT MORE THAN 400°F FOR A PERIOD NOT TO EXCEED

30 MINUTES TO FACILITATE FORMING OR BENDING TO HORIZONTAL

CURVATURE.

SHOP DRAWINGS OF RAILING SHALL BE SUBMITTED AS A TYPE 2 WORKING

DRAWING SHOWING COMPLETE DIMENSIONS AND DETAILS OF FABRICATION AND

INCLUDING AN ERECTION DIAGRAM. MATERIAL SPECIFICATIONS SHALL BE

PROVIDED IN THE SHOP DRAWINGS FOR ALL COMPONENTS.

CUTTING SHALL BE DONE BY SAWING OR MILLING AND ALL CUTS SHALL BE

TRUE AND SMOOTH. FLAME CUTTING WILL NOT BE PERMITTED.

WELDING OF ALUMINUM SHALL CONFORM TO STD. SPEC. SECTION 9-28.14(3).

ALL ALUMINUM PARTS SHALL BE GIVEN A *[CLEAR OR BRONZE] ANODIC

COATING OF AT LEAST 0.0006" THICK AND SEALED TO MEET THE

REQUIREMENTS OF ASTM B 580 WITH A UNIFORM FINISH.

PIPE RAILING, PIPE BALUSTERS AND PIPE RAILING SPLICES SHALL BE

ADEQUATELY WRAPPED TO INSURE SURFACE PROTECTION DURING HANDLING

AND TRANSPORTATION TO THE JOB SITE.

GENERAL NOTES:

2½"ø NOMINAL

PIPE CAP (TYP.)

2½"ø NOM.

PIPE CAP (TYP.)

2'-6" CONC.

PEDESTAL

BK. OF PAV'T. SEAT

¢ POST

2"

GAP

10"

¢ POST

BRIDGE APPROACH SLAB BRIDGE

10" 1½"

GAP

File details come from the government source that posted it. Updated .