Report Date: 31-Jan-2025 10:52:41 Chrom Revision: 2.3 15-Jan-2025 12:44:04
Eurofins Pittsburgh Data File: \\chromfs\Pittsburgh\ChromData\CHGC15\20250123-55310.b\0122250000140.D
Injection Date: 24-Jan-2025 05:12:11 Instrument ID: CHGC15 Operator ID:
Lims ID: 180-185041-A-10-F Lab Sample ID: 180-185041-10 Worklist Smp#: 24
Client ID: #20250076 AMENDED COMPOSITE K
Injection Vol: 1.0 ul Dil. Factor: 20.0000 ALS Bottle#: 144
Method: IS PEST_CHGC15 Limit Group: GCS 8081B ICAL with IS
Column: MR-1 ( 0.53 mm)
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0 13.0 14.0 15.0 Min
Y
X
GC ECD1A, 0122250000140.D
-B ro m o
-2 -n it ro b e n z e n e
.5
T e tr a c h lo ro
-m -x y le n e
.1
,4 D
D D
.1
D
D T
.6
P
C B
-2
IS
.4
D
C B
D e c a c h lo ro b ip h e n y l (S u rr
.0
Column: MR-2 ( 0.53 mm)
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0 13.0 14.0 15.0 Min
Y
X
GC ECD2B, 0122250000140.D
-B ro m o
-2 -n it ro b e n z e n e
.8
T e tr a c h lo ro
-m -x y le n e
.6
D
D D
.0
D
D T
.5
P
C B
-2
IS
.9
D
C B
D e c a c h lo ro b ip h e n y l (S u rr
.6
Page 5756 of 15442
Recovery Report
Data File: \\chromfs\Pittsburgh\ChromData\CHGC15\20250123-55310.b\0122250000140.D
Lims ID: 180-185041-A-10-F
Client ID: #20250076 AMENDED COMPOSITE K
Sample Type: Client
Inject. Date: 24-Jan-2025 05:12:11 ALS Bottle#: 144 Worklist Smp#: 24
Injection Vol: 1.0 ul Dil. Factor: 20.0000
Sample Info: 180-0055310-024
Operator ID: Instrument ID: CHGC15
Method: \\chromfs\Pittsburgh\ChromData\CHGC15\20250123-55310.b\IS PEST_CHGC15.m
Limit Group: GCS 8081B ICAL with IS
Last Update: 31-Jan-2025 10:52:00 Calib Date: 28-May-2024 11:43:25
Integrator: Falcon
Quant Method: Internal Standard Quant By: Initial Calibration
Last ICal File: \\chromfs\Pittsburgh\ChromData\CHGC15\20240528-52583.b\0528240000008.D
Column 1 : MR-1 ( 0.53 mm) Det: GC ECD1A
Column 2 : MR-2 ( 0.53 mm) Det: GC ECD2B
Process Host: CTX1679
First Level Reviewer: XXL1 Date: 24-Jan-2025 14:41:24
Surrogate Recovery, Detector: GC ECD1A
Compound Amount Added
Amount Recovered % Rec.
$ 3 Tetrachloro-m-xylene 0.0200 0.001178 117.80
$ 39 DCB Decachlorobiphenyl (Surr) 0.0200 0.001338 133.84
Surrogate Recovery, Detector: GC ECD2B
Compound Amount Added
Amount Recovered % Rec.
$ 3 Tetrachloro-m-xylene 0.0200 0.000727 72.67
$ 39 DCB Decachlorobiphenyl (Surr) 0.0200 0.001569 156.94
Page 5757 of 15442
User Disabled Compound Report
Eurofins Pittsburgh
Data File: \\chromfs\Pittsburgh\ChromData\CHGC15\20250123-55310.b\0122250000140.D
Injection Date: 24-Jan-2025 05:12:11 Instrument ID: CHGC15
Lims ID: 180-185041-A-10-F Lab Sample ID: 180-185041-10
Client ID: #20250076 AMENDED COMPOSITE K
Operator ID: ALS Bottle#: 144 Worklist Smp#: 24
Injection Vol: 1.0 ul Dil. Factor: 20.0000
Method: IS PEST_CHGC15 Limit Group: GCS 8081B ICAL with IS
Column: MR-1 ( 0.53 mm) Detector GC ECD1A
5 alpha-BHC, CAS: 319-84-6, Signal: 1
RT: 3.62
Response: 355568
Amount: 0.000176
3.4 3.6 Min
RT
Y
X
GC ECD1A, 0122250000140.D
.6
Column: MR-2 ( 0.53 mm) Detector GC ECD2B
5 alpha-BHC, CAS: 319-84-6, Signal: 2
RT: 4.31
Response: 1817202
Amount: 0.000699
4.1 4.3 4.5 Min
RT
Y
X
GC ECD2B, 0122250000140.D
.3
Reviewer: XXL1, 24-Jan-2025 14:41:24
Audit Action: Marked Compound Undetected Audit Reason: Invalid Compound ID
Page 5758 of 15442
Eurofins Pittsburgh
Data File: \\chromfs\Pittsburgh\ChromData\CHGC15\20250123-55310.b\0122250000140.D
Injection Date: 24-Jan-2025 05:12:11 Instrument ID: CHGC15
Lims ID: 180-185041-A-10-F Lab Sample ID: 180-185041-10
Client ID: #20250076 AMENDED COMPOSITE K
Operator ID: ALS Bottle#: 144 Worklist Smp#: 24
Injection Vol: 1.0 ul Dil. Factor: 20.0000
Method: IS PEST_CHGC15 Limit Group: GCS 8081B ICAL with IS
Column: MR-1 ( 0.53 mm) Detector GC ECD1A
7 gamma-BHC (Lindane), CAS: 58-89-9, Signal: 1
RT: 3.94
Response: 596646
Amount: 0.000354
3.8 4.0 Min
RT
Y
X
.9
Column: MR-2 ( 0.53 mm) Detector GC ECD2B
7 gamma-BHC (Lindane), CAS: 58-89-9, Signal: 2
RT: 4.77
Response: 473774
Amount: 0.000217
4.6 4.8 5.0 Min
RT
Y
X
.7
Reviewer: XXL1, 24-Jan-2025 14:41:24
Page 5759 of 15442
Eurofins Pittsburgh
Data File: \\chromfs\Pittsburgh\ChromData\CHGC15\20250123-55310.b\0122250000140.D
Injection Date: 24-Jan-2025 05:12:11 Instrument ID: CHGC15
Lims ID: 180-185041-A-10-F Lab Sample ID: 180-185041-10
Client ID: #20250076 AMENDED COMPOSITE K
Operator ID: ALS Bottle#: 144 Worklist Smp#: 24
Injection Vol: 1.0 ul Dil. Factor: 20.0000
Method: IS PEST_CHGC15 Limit Group: GCS 8081B ICAL with IS
Column: MR-1 ( 0.53 mm) Detector GC ECD1A
20 cis-Chlordane, CAS: 5103-71-9, Signal: 1
RT: 5.98
Response: 692441
Amount: 0.000649
5.8 6.0 Min
RT
Y
X
Column: MR-2 ( 0.53 mm) Detector GC ECD2B
20 cis-Chlordane, CAS: 5103-71-9, Signal: 2
RT: 7.51
Response: 723481
Amount: 0.000533
7.3 7.5 Min
RT
Y
X
.5
Reviewer: XXL1, 24-Jan-2025 14:41:24
Page 5760 of 15442
Eurofins Pittsburgh
Data File: \\chromfs\Pittsburgh\ChromData\CHGC15\20250123-55310.b\0122250000140.D
Injection Date: 24-Jan-2025 05:12:11 Instrument ID: CHGC15
Lims ID: 180-185041-A-10-F Lab Sample ID: 180-185041-10
Client ID: #20250076 AMENDED COMPOSITE K
Operator ID: ALS Bottle#: 144 Worklist Smp#: 24
Injection Vol: 1.0 ul Dil. Factor: 20.0000
Method: IS PEST_CHGC15 Limit Group: GCS 8081B ICAL with IS
Column: MR-1 ( 0.53 mm) Detector GC ECD1A
18 trans-Chlordane, CAS: 5103-74-2, Signal: 1
RT: 5.76
Response: 927234
Amount: 0.000847
5.6 5.8 Min
RT
Y
X
Column: MR-2 ( 0.53 mm) Detector GC ECD2B
18 trans-Chlordane, CAS: 5103-74-2, Signal: 2
RT: 7.24
Response: 4338305
Amount: 0.003035
7.1 7.3 Min
RT
Y
X
.2
Reviewer: XXL1, 24-Jan-2025 14:41:24
Page 5761 of 15442
Eurofins Pittsburgh
Data File: \\chromfs\Pittsburgh\ChromData\CHGC15\20250123-55310.b\0122250000140.D
Injection Date: 24-Jan-2025 05:12:11 Instrument ID: CHGC15
Lims ID: 180-185041-A-10-F Lab Sample ID: 180-185041-10
Client ID: #20250076 AMENDED COMPOSITE K
Operator ID: ALS Bottle#: 144 Worklist Smp#: 24
Injection Vol: 1.0 ul Dil. Factor: 20.0000
Method: IS PEST_CHGC15 Limit Group: GCS 8081B ICAL with IS
Column: MR-1 ( 0.53 mm) Detector GC ECD1A
35 Endosulfan sulfate, CAS: 1031-07-8, Signal: 1
RT: 8.99
Response: 897291
Amount: 0.000879
8.8 9.0 9.2 Min
RT
Y
X
Column: MR-2 ( 0.53 mm) Detector GC ECD2B
35 Endosulfan sulfate, CAS: 1031-07-8, Signal: 2
RT: 10.19
Response: 757311
Amount: 0.000566
10.0 10.2 10.4 Min
RT
Y
X
GC ECD2B, 0122250000140.D
.1
Reviewer: XXL1, 24-Jan-2025 14:41:24
Page 5762 of 15442
Eurofins Pittsburgh
Data File: \\chromfs\Pittsburgh\ChromData\CHGC15\20250123-55310.b\0122250000140.D
Injection Date: 24-Jan-2025 05:12:11 Instrument ID: CHGC15
Lims ID: 180-185041-A-10-F Lab Sample ID: 180-185041-10
Client ID: #20250076 AMENDED COMPOSITE K
Operator ID: ALS Bottle#: 144 Worklist Smp#: 24
Injection Vol: 1.0 ul Dil. Factor: 20.0000
Method: IS PEST_CHGC15 Limit Group: GCS 8081B ICAL with IS
Column: MR-1 ( 0.53 mm) Detector GC ECD1A
16 Heptachlor epoxide, CAS: 1024-57-3, Signal: 1
RT: 5.61
Response: 2083598
Amount: 0.001957
5.4 5.6 5.8 Min
RT
Y
X
Column: MR-2 ( 0.53 mm) Detector GC ECD2B
16 Heptachlor epoxide, CAS: 1024-57-3, Signal: 2
RT: 6.89
Response: 2265474
Amount: 0.001607
6.7 6.9 7.1 Min
RT
Y
X
.8
Reviewer: XXL1, 31-Jan-2025 10:52:00
Page 5763 of 15442
FORM I
PESTICIDES ORGANICS ANALYSIS DATA SHEET
Lab Name: Job No.: 180-185041-1Eurofins Pittsburgh
SDG No.:
Client Sample ID: #20250076 AMENDED
COMPOSITE K RE
Lab Sample ID: 180-185041-10 RE
Matrix: 0128250000048.DLab File ID:
Date Collected:EPA 8081B LLAnalysis Method:
Sediment
01/06/2025 10:41
Con. Extract Vol.:
Injection Volume:
GPC Cleanup:(Y/N)
Date Extracted:
Date Analyzed:
Dilution Factor: 20
Extraction Method: 3541 01/27/2025 07:23
01/28/2025 23:57
1.0(mL)
1(uL)
Sample wt/vol: 30.1(g)
% Moisture: 56.0
GC Column: ID: 0.53(mm)MR-1
N% Solids: 44.0
Cleanup Factor:
Analysis Batch No.: 489125 ug/KgUnits:
Preparation Batch No.: Instrument ID: 489053 CHGC15
%RECCAS NO. LIMITSQSURROGATE
101 32-147877-09-8 Tetrachloro-m-xylene (Surr)
94 30-1502051-24-3 DCB Decachlorobiphenyl (Surr)
FORM I EPA 8081B LL
Page 5764 of 15442
Report Date: 29-Jan-2025 11:14:22 Chrom Revision: 2.3 15-Jan-2025 12:44:04
Target Compound Quantitation Report
Data File: \\chromfs\Pittsburgh\ChromData\CHGC15\20250128-55352.b\0128250000048.D
Lims ID: 180-185041-A-10-P
Client ID: #20250076 AMENDED COMPOSITE K
Sample Type: Client
Inject. Date: 28-Jan-2025 23:57:03 ALS Bottle#: 48 Worklist Smp#: 48
Injection Vol: 1.0 ul Dil. Factor: 20.0000
Sample Info: 180-0055352-048
Operator ID: Instrument ID: CHGC15
Method: \\chromfs\Pittsburgh\ChromData\CHGC15\20250128-55352.b\IS PEST_CHGC15.m
Limit Group: GCS 8081B ICAL with IS
Last Update: 29-Jan-2025 11:13:37 Calib Date: 28-May-2024 11:43:25
Integrator: Falcon
Quant Method: Internal Standard Quant By: Initial Calibration
Last ICal File: \\chromfs\Pittsburgh\ChromData\CHGC15\20240528-52583.b\0528240000008.D
Column 1 : MR-1 ( 0.53 mm) Det: GC ECD1A
Column 2 : MR-2 ( 0.53 mm) Det: GC ECD2B
Process Host: CTX1713
First Level Reviewer: XXL1 Date: 29-Jan-2025 11:12:50
Col
RT
(min.)
Exp RT (min.)
Dlt RT (min.) Response
OnCol Amt ng Flags
* 43 1-Bromo-2-nitrobenzene
1 2.576 2.576 0.000 134006912H 0.1000
2 2.818 2.818 0.000 188755529H 0.1000
$ 3 Tetrachloro-m-xylene
1 3.147 3.148 -0.001 1704559H 0.001010
2 3.632 3.632 0.000 1113041H 0.000490
RPD = 69.21
5 alpha-BHC U
1 3.616 ND
2 4.298
7 gamma-BHC (Lindane) 7
1 3.918 ND
2 4.749
8 beta-BHC 7
1 4.000 ND
2 4.850
10 delta-BHC
1 4.190 ND
2 5.272
Page 5765 of 15442
Data File: \\chromfs\Pittsburgh\ChromData\CHGC15\20250128-55352.b\0128250000048.D
Col
RT
(min.)
Exp RT (min.)
Dlt RT (min.) Response
OnCol Amt ng Flags
9 Chlordane (technical) 7
1 4.341 ND
1 4.433
1 5.776
1 5.962
2 5.389
2 7.215
2 7.399
2 7.495
11 Heptachlor 7
1 4.429 ND
2 5.386
13 Aldrin
1 4.786 ND
2 5.894
16 Heptachlor epoxide U
1 5.585 ND
2 6.862
18 trans-Chlordane
1 5.773 ND
2 7.214
20 cis-Chlordane 7
1 5.973 ND
2 7.494
21 Endosulfan I
1 6.125 ND
2 7.600
23 4,4'-DDE
1 6.173 ND
2 7.868
24 Dieldrin 7
1 6.563 ND
2 8.163
27 Endrin
1 6.948 ND
2 8.742
29 4,4'-DDD M
1 7.132 7.132 0.000 573269H 0.000636
2 9.002 9.000 0.002 706416H 0.000510 M
RPD = 21.95
31 Endosulfan II
1 7.340 ND
2 9.129
Page 5766 of 15442
Col
RT
(min.)
Exp RT (min.)
Dlt RT (min.) Response
OnCol Amt ng Flags
34 Toxaphene
1 7.566 ND
1 8.140
1 8.788
1 9.407
2 9.284
2 9.736
2 10.530
2 11.114
33 4,4'-DDT
1 7.662 ND
2 9.549
36 Methoxychlor 7
1 8.681 ND
2 10.662
38 Mirex
1 8.773 ND
2 10.896
35 Endosulfan sulfate U
1 8.954 ND
2 10.165
* 61 PCB-205 (IS)
1 10.466 10.465 0.000 123763861H 0.1000
2 11.957 11.959 -0.001 176797192H 0.1000
* 44 Dibutylchlorendate ISTD
1 10.956 ND
2 12.203
$ 39 DCB Decachlorobiphenyl (Surr)
1 11.085 11.085 0.000 1009873H 0.000938
2 12.678 12.677 0.001 1145570H 0.000799
RPD = 16.04
S 62 Endosulfan, Total
1 0.000 ND
QC Flag Legend Processing Flags
7 - Failed Limit of Detection
H - Response Measured by Height
Review Flags
M - Manually Integrated
U - Marked Undetected
Reagents:
PCBINT_00033 Amount Added: 0.01 Units: mL Run Reagent
Page 5767 of 15442
Data File: \\chromfs\Pittsburgh\ChromData\CHGC15\20250128-55352.b\0128250000048.D
Injection Date: 28-Jan-2025 23:57:03 Instrument ID: CHGC15 Operator ID:
Lims ID: 180-185041-A-10-P Lab Sample ID: 180-185041-10 Worklist Smp#: 48
Client ID: #20250076 AMENDED COMPOSITE K
Injection Vol: 1.0 ul Dil. Factor: 20.0000 ALS Bottle#: 48
Method: IS PEST_CHGC15 Limit Group: GCS 8081B ICAL with IS
Column: MR-1 ( 0.53 mm)
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0 13.0 14.0 15.0 Min
Y
X
GC ECD1A, 0128250000048.D
-B ro m o
-2 -n it ro b e n z e n e
.5
T e tr a c h lo ro
-m -x y le n e
.1
D
D D
.1
P
C B
-2
IS
.4
D
C B
D e c a c h lo ro b ip h e n y l (S u rr
.0
Column: MR-2 ( 0.53 mm)
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0 13.0 14.0 15.0 Min
Y
X
GC ECD2B, 0128250000048.D
-B ro m o
-2 -n it ro b e n z e n e
.8
T e tr a c h lo ro
-m -x y le n e
.6
D
D D
.0
P
C B
-2
IS
.9
D
C B
D e c a c h lo ro b ip h e n y l (S u rr
.6
Page 5768 of 15442
Recovery Report
Data File: \\chromfs\Pittsburgh\ChromData\CHGC15\20250128-55352.b\0128250000048.D
Lims ID: 180-185041-A-10-P
Client ID: #20250076 AMENDED COMPOSITE K
Sample Type: Client
Inject. Date: 28-Jan-2025 23:57:03 ALS Bottle#: 48 Worklist Smp#: 48
Injection Vol: 1.0 ul Dil. Factor: 20.0000
Sample Info: 180-0055352-048
Operator ID: Instrument ID: CHGC15
Method: \\chromfs\Pittsburgh\ChromData\CHGC15\20250128-55352.b\IS PEST_CHGC15.m
Limit Group: GCS 8081B ICAL with IS
Last Update: 29-Jan-2025 11:13:37 Calib Date: 28-May-2024 11:43:25
Integrator: Falcon
Quant Method: Internal Standard Quant By: Initial Calibration
Last ICal File: \\chromfs\Pittsburgh\ChromData\CHGC15\20240528-52583.b\0528240000008.D
Column 1 : MR-1 ( 0.53 mm) Det: GC ECD1A
Column 2 : MR-2 ( 0.53 mm) Det: GC ECD2B
Process Host: CTX1713
First Level Reviewer: XXL1 Date: 29-Jan-2025 11:12:50
Surrogate Recovery, Detector: GC ECD1A
Compound Amount Added
Amount Recovered % Rec.
$ 3 Tetrachloro-m-xylene 0.0200 0.001010 100.96
$ 39 DCB Decachlorobiphenyl (Surr) 0.0200 0.000938 93.80
Surrogate Recovery, Detector: GC ECD2B
Compound Amount Added
Amount Recovered % Rec.
$ 3 Tetrachloro-m-xylene 0.0200 0.000490 49.05
$ 39 DCB Decachlorobiphenyl (Surr) 0.0200 0.000799 79.87
Page 5769 of 15442
Eurofins Pittsburgh
Data File: \\chromfs\Pittsburgh\ChromData\CHGC15\20250128-55352.b\0128250000048.D
Injection Date: 28-Jan-2025 23:57:03 Instrument ID: CHGC15
Lims ID: 180-185041-A-10-P Lab Sample ID: 180-185041-10
Client ID: #20250076 AMENDED COMPOSITE K
Operator ID: ALS Bottle#: 48 Worklist Smp#: 48
Injection Vol: 1.0 ul Dil. Factor: 20.0000
Method: IS PEST_CHGC15 Limit Group: GCS 8081B ICAL with IS
Column: MR-1 ( 0.53 mm) Detector GC ECD1A
5 alpha-BHC, CAS: 319-84-6, Signal: 1
RT: 3.64
Response: 1980357
Amount: 0.000835
3.5 3.7 Min
RT
Y
X
GC ECD1A, 0128250000048.D
Column: MR-2 ( 0.53 mm) Detector GC ECD2B
5 alpha-BHC, CAS: 319-84-6, Signal: 2
RT: 4.30
Response: 1580082
Amount: 0.000529
4.1 4.3 4.5 Min
RT
Y
X
GC ECD2B, 0128250000048.D
Reviewer: XXL1, 29-Jan-2025 11:12:50
Page 5770 of 15442
Eurofins Pittsburgh
Data File: \\chromfs\Pittsburgh\ChromData\CHGC15\20250128-55352.b\0128250000048.D
Injection Date: 28-Jan-2025 23:57:03 Instrument ID: CHGC15
Lims ID: 180-185041-A-10-P Lab Sample ID: 180-185041-10
Client ID: #20250076 AMENDED COMPOSITE K
Operator ID: ALS Bottle#: 48 Worklist Smp#: 48
Injection Vol: 1.0 ul Dil. Factor: 20.0000
Method: IS PEST_CHGC15 Limit Group: GCS 8081B ICAL with IS
Column: MR-1 ( 0.53 mm) Detector GC ECD1A
35 Endosulfan sulfate, CAS: 1031-07-8, Signal: 1
RT: 8.98
Response: 552314
Amount: 0.000516
8.8 9.0 Min
RT
Y
X
Column: MR-2 ( 0.53 mm) Detector GC ECD2B
35 Endosulfan sulfate, CAS: 1031-07-8, Signal: 2
RT: 10.18
Response: 186667
Amount: 0.000141
10.0 10.2 10.4 Min
RT
Y
X
GC ECD2B, 0128250000048.D
.1
Reviewer: XXL1, 29-Jan-2025 11:12:50
Page 5771 of 15442
Eurofins Pittsburgh
Data File: \\chromfs\Pittsburgh\ChromData\CHGC15\20250128-55352.b\0128250000048.D
Injection Date: 28-Jan-2025 23:57:03 Instrument ID: CHGC15
Lims ID: 180-185041-A-10-P Lab Sample ID: 180-185041-10
Client ID: #20250076 AMENDED COMPOSITE K
Operator ID: ALS Bottle#: 48 Worklist Smp#: 48
Injection Vol: 1.0 ul Dil. Factor: 20.0000
Method: IS PEST_CHGC15 Limit Group: GCS 8081B ICAL with IS
Column: MR-1 ( 0.53 mm) Detector GC ECD1A
16 Heptachlor epoxide, CAS: 1024-57-3, Signal: 1
RT: 5.60
Response: 498945
Amount: 0.000399
5.4 5.6 5.8 Min
RT
Y
X
Column: MR-2 ( 0.53 mm) Detector GC ECD2B
16 Heptachlor epoxide, CAS: 1024-57-3, Signal: 2
RT: 6.87
Response: 1161526
Amount: 0.000717
6.7 6.9 Min
RT
Y
X
Reviewer: XXL1, 29-Jan-2025 11:12:50
Page 5772 of 15442
Lab Name: Job No.: 180-185041-1Eurofins Pittsburgh
SDG No.:
Client Sample ID: #20250076 AMENDED
COMPOSITE K RE
Lab Sample ID: 180-185041-10 RE
Matrix: 0128250000048.DLab File ID:
Date Collected:EPA 8081B LLAnalysis Method:
Sediment
01/06/2025 10:41
Con. Extract Vol.:
Injection Volume:
GPC Cleanup:(Y/N)
Date Extracted:
Date Analyzed:
Dilution Factor: 20
Extraction Method: 3541 01/27/2025 07:23
01/28/2025 23:57
1.0(mL)
1(uL)
Sample wt/vol: 30.1(g)
% Moisture: 56.0
GC Column: ID: 0.53(mm)MR-2
N% Solids: 44.0
Cleanup Factor:
Analysis Batch No.: 489125 ug/KgUnits:
Preparation Batch No.: Instrument ID: 489053 CHGC15
CAS NO. COMPOUND NAME RESULT Q MDLRL
1.9 0.59U H309-00-2 Aldrin 1.9
1.9 0.46U H319-84-6 alpha-BHC 1.9
1.9 0.52U H319-85-7 beta-BHC 1.9
1.9 0.60U H319-86-8 delta-BHC 1.9
1.9 0.49U H58-89-9 gamma-BHC (Lindane) 1.9
1.9 0.47U H5103-71-9 cis-Chlordane 1.9
1.9 0.44U H5103-74-2 trans-Chlordane 1.9
1.9 0.40J H72-54-8 4,4'-DDD 0.77
1.9 0.38U H72-55-9 4,4'-DDE 1.9
1.9 1.4U H50-29-3 4,4'-DDT 1.9
1.9 0.47U H60-57-1 Dieldrin 1.9
1.9 0.51U H959-98-8 Endosulfan I 1.9
1.9 0.42U H33213-65-9 Endosulfan II 1.9
1.9 0.87U H1031-07-8 Endosulfan sulfate 1.9
1.9 0.35U H72-20-8 Endrin 1.9
1.9 0.59U H76-44-8 Heptachlor 1.9
1.9 0.48U H1024-57-3 Heptachlor epoxide 1.9
1.9 0.74U H72-43-5 Methoxychlor 1.9
1.9 1.4U H2385-85-5 Mirex 1.9
75 51U H8001-35-2 Toxaphene 75
3.8 0.93U H115-29-7 Endosulfan, Total 3.8
%RECCAS NO. LIMITSQSURROGATE
p49 32-147877-09-8 Tetrachloro-m-xylene (Surr)
80 30-1502051-24-3 DCB Decachlorobiphenyl (Surr)
Page 5773 of 15442
Target Compound Quantitation Report
Data File: \\chromfs\Pittsburgh\ChromData\CHGC15\20250128-55352.b\0128250000048.D
Lims ID: 180-185041-A-10-P
Client ID: #20250076 AMENDED COMPOSITE K
Sample Type: Client
Inject. Date: 28-Jan-2025 23:57:03 ALS Bottle#: 48 Worklist Smp#: 48
Injection Vol: 1.0 ul Dil. Factor: 20.0000
Sample Info: 180-0055352-048
Operator ID: Instrument ID: CHGC15
Method: \\chromfs\Pittsburgh\ChromData\CHGC15\20250128-55352.b\IS PEST_CHGC15.m
Limit Group: GCS 8081B ICAL with IS
Last Update: 29-Jan-2025 11:13:37 Calib Date: 28-May-2024 11:43:25
Integrator: Falcon
Quant Method: Internal Standard Quant By: Initial Calibration
Last ICal File: \\chromfs\Pittsburgh\ChromData\CHGC15\20240528-52583.b\0528240000008.D
Column 1 : MR-1 ( 0.53 mm) Det: GC ECD1A
Column 2 : MR-2 ( 0.53 mm) Det: GC ECD2B
Process Host: CTX1713
First Level Reviewer: XXL1 Date: 29-Jan-2025 11:12:50
Col
RT
(min.)
Exp RT (min.)
Dlt RT (min.) Response
OnCol Amt ng Flags
* 43 1-Bromo-2-nitrobenzene
1 2.576 2.576 0.000 134006912H 0.1000
2 2.818 2.818 0.000 188755529H 0.1000
$ 3 Tetrachloro-m-xylene
1 3.147 3.148 -0.001 1704559H 0.001010
2 3.632 3.632 0.000 1113041H 0.000490
RPD = 69.21
5 alpha-BHC U
1 3.616 ND
2 4.298
7 gamma-BHC (Lindane) 7
1 3.918 ND
2 4.749
8 beta-BHC 7
1 4.000 ND
2 4.850
10 delta-BHC
1 4.190 ND
2 5.272
Page 5774 of 15442
Col
RT
(min.)
Exp RT (min.)
Dlt RT (min.) Response
OnCol Amt ng Flags
9 Chlordane (technical) 7
1 4.341 ND
1 4.433
1 5.776
1 5.962
2 5.389
2 7.215
2 7.399
2 7.495
11 Heptachlor 7
1 4.429 ND
2 5.386
13 Aldrin
1 4.786 ND
2 5.894
16 Heptachlor epoxide U
1 5.585 ND
2 6.862
18 trans-Chlordane
1 5.773 ND
2 7.214
20 cis-Chlordane 7
1 5.973 ND
2 7.494
21 Endosulfan I
1 6.125 ND
2 7.600
23 4,4'-DDE
1 6.173 ND
2 7.868
24 Dieldrin 7
1 6.563 ND
2 8.163
27 Endrin
1 6.948 ND
2 8.742
29 4,4'-DDD M
1 7.132 7.132 0.000 573269H 0.000636
2 9.002 9.000 0.002 706416H 0.000510 M
RPD = 21.95
31 Endosulfan II
1 7.340 ND
2 9.129
Page 5775 of 15442
Col
RT
(min.)
Exp RT (min.)
Dlt RT (min.) Response
OnCol Amt ng Flags
34 Toxaphene
1 7.566 ND
1 8.140
1 8.788
1 9.407
2 9.284
2 9.736
2 10.530
2 11.114
33 4,4'-DDT
1 7.662 ND
2 9.549
36 Methoxychlor 7
1 8.681 ND
2 10.662
38 Mirex
1 8.773 ND
2 10.896
35 Endosulfan sulfate U
1 8.954 ND
2 10.165
* 61 PCB-205 (IS)
1 10.466 10.465 0.000 123763861H 0.1000
2 11.957 11.959 -0.001 176797192H 0.1000
* 44 Dibutylchlorendate ISTD
1 10.956 ND
2 12.203
$ 39 DCB Decachlorobiphenyl (Surr)
1 11.085 11.085 0.000 1009873H 0.000938
2 12.678 12.677 0.001 1145570H 0.000799
RPD = 16.04
S 62 Endosulfan, Total
1 0.000 ND
QC Flag Legend Processing Flags
7 - Failed Limit of Detection
H - Response Measured by Height
Review Flags
M - Manually Integrated
U - Marked Undetected
Reagents:
PCBINT_00033 Amount Added: 0.01 Units: mL Run Reagent
Page 5776 of 15442
Report Date: 29-Jan-2025 11:14:23 Chrom Revision: 2.3 15-Jan-2025 12:44:04
Data File: \\chromfs\Pittsburgh\ChromData\CHGC15\20250128-55352.b\0128250000048.D
Injection Date: 28-Jan-2025 23:57:03 Instrument ID: CHGC15 Operator ID:
Lims ID: 180-185041-A-10-P Lab Sample ID: 180-185041-10 Worklist Smp#: 48
Client ID: #20250076 AMENDED COMPOSITE K
Injection Vol: 1.0 ul Dil. Factor: 20.0000 ALS Bottle#: 48
Method: IS PEST_CHGC15 Limit Group: GCS 8081B ICAL with IS
Column: MR-1 ( 0.53 mm)
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0 13.0 14.0 15.0 Min
Y
X
GC ECD1A, 0128250000048.D
-B ro m o
-2 -n it ro b e n z e n e
.5
T e tr a c h lo ro
-m -x y le n e
.1
D
D D
.1
P
C B
-2
IS
.4
D
C B
D e c a c h lo ro b ip h e n y l (S u rr
.0
Column: MR-2 ( 0.53 mm)
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0 13.0 14.0 15.0 Min
Y
X
GC ECD2B, 0128250000048.D
-B ro m o
-2 -n it ro b e n z e n e
.8
T e tr a c h lo ro
-m -x y le n e
.6
D
D D
.0
P
C B
-2
IS
.9
D
C B
D e c a c h lo ro b ip h e n y l (S u rr
.6
Page 5777 of 15442
Recovery Report
Data File: \\chromfs\Pittsburgh\ChromData\CHGC15\20250128-55352.b\0128250000048.D
Lims ID: 180-185041-A-10-P
Client ID: #20250076 AMENDED COMPOSITE K
Sample Type: Client
Inject. Date: 28-Jan-2025 23:57:03 ALS Bottle#: 48 Worklist Smp#: 48
Injection Vol: 1.0 ul Dil. Factor: 20.0000
Sample Info: 180-0055352-048
Operator ID: Instrument ID: CHGC15
Method: \\chromfs\Pittsburgh\ChromData\CHGC15\20250128-55352.b\IS PEST_CHGC15.m
Limit Group: GCS 8081B ICAL with IS
Last Update: 29-Jan-2025 11:13:37 Calib Date: 28-May-2024 11:43:25
Integrator: Falcon
Quant Method: Internal Standard Quant By: Initial Calibration
Last ICal File: \\chromfs\Pittsburgh\ChromData\CHGC15\20240528-52583.b\0528240000008.D
Column 1 : MR-1 ( 0.53 mm) Det: GC ECD1A
Column 2 : MR-2 ( 0.53 mm) Det: GC ECD2B
Process Host: CTX1713
First Level Reviewer: XXL1 Date: 29-Jan-2025 11:12:50
Surrogate Recovery, Detector: GC ECD1A
Compound Amount Added
Amount Recovered % Rec.
$ 3 Tetrachloro-m-xylene 0.0200 0.001010 100.96
$ 39 DCB Decachlorobiphenyl (Surr) 0.0200 0.000938 93.80
Surrogate Recovery, Detector: GC ECD2B
Compound Amount Added
Amount Recovered % Rec.
$ 3 Tetrachloro-m-xylene 0.0200 0.000490 49.05
$ 39 DCB Decachlorobiphenyl (Surr) 0.0200 0.000799 79.87
Page 5778 of 15442
Eurofins Pittsburgh
Data File: \\chromfs\Pittsburgh\ChromData\CHGC15\20250128-55352.b\0128250000048.D
Injection Date: 28-Jan-2025 23:57:03 Instrument ID: CHGC15
Lims ID: 180-185041-A-10-P Lab Sample ID: 180-185041-10
Client ID: #20250076 AMENDED COMPOSITE K
Operator ID: ALS Bottle#: 48 Worklist Smp#: 48
Injection Vol: 1.0 ul Dil. Factor: 20.0000
Method: IS PEST_CHGC15 Limit Group: GCS 8081B ICAL with IS
Column: MR-1 ( 0.53 mm) Detector GC ECD1A
5 alpha-BHC, CAS: 319-84-6, Signal: 1
RT: 3.64
Response: 1980357
Amount: 0.000835
3.5 3.7 Min
RT
Y
X
Column: MR-2 ( 0.53 mm) Detector GC ECD2B
5 alpha-BHC, CAS: 319-84-6, Signal: 2
RT: 4.30
Response: 1580082
Amount: 0.000529
4.1 4.3 4.5 Min
RT
Y
X
Reviewer: XXL1, 29-Jan-2025 11:12:50
Page 5779 of 15442
Manual Integration/User Assign Peak Report
Eurofins Pittsburgh
Data File: \\chromfs\Pittsburgh\ChromData\CHGC15\20250128-55352.b\0128250000048.D
Injection Date: 28-Jan-2025 23:57:03 Instrument ID: CHGC15
Lims ID: 180-185041-A-10-P Lab Sample ID: 180-185041-10
Client ID: #20250076 AMENDED COMPOSITE K
Operator ID: ALS Bottle#: 48 Worklist Smp#: 48
Injection Vol: 1.0 ul Dil. Factor: 20.0000
Method: IS PEST_CHGC15 Limit Group: GCS 8081B ICAL with IS
Column: MR-2 ( 0.53 mm) Detector GC ECD2B
29 4,4'-DDD, CAS: 72-54-8
Signal: 2
Processing Integration Results
RT: 9.00
Height: 368768
Amount: 0.000266
Amount Units: ng
8.7 8.9 9.1 9.3 Min
Y
X
Manual Integration Results
RT: 9.00
Height: 706416
Amount: 0.000510
Amount Units: ng
8.7 8.9 9.1 9.3 Min
RT
Y
X
.0
Reviewer: XXL1, 29-Jan-2025 11:12:35 -05:00:00 (UTC)
Audit Action: Manually Integrated Audit Reason: Incomplete Integration
Page 5780 of 15442
Eurofins Pittsburgh
Data File: \\chromfs\Pittsburgh\ChromData\CHGC15\20250128-55352.b\0128250000048.D
Injection Date: 28-Jan-2025 23:57:03 Instrument ID: CHGC15
Lims ID: 180-185041-A-10-P Lab Sample ID: 180-185041-10
Client ID: #20250076 AMENDED COMPOSITE K
Operator ID: ALS Bottle#: 48 Worklist Smp#: 48
Injection Vol: 1.0 ul Dil. Factor: 20.0000
Method: IS PEST_CHGC15 Limit Group: GCS 8081B ICAL with IS
Column: MR-1 ( 0.53 mm) Detector GC ECD1A
35 Endosulfan sulfate, CAS: 1031-07-8, Signal: 1
RT: 8.98
Response: 552314
Amount: 0.000516
8.8 9.0 Min
RT
Y
X
Column: MR-2 ( 0.53 mm) Detector GC ECD2B
35 Endosulfan sulfate, CAS: 1031-07-8, Signal: 2
RT: 10.18
Response: 186667
Amount: 0.000141
10.0 10.2 10.4 Min
RT
Y
X
GC ECD2B, 0128250000048.D
.1
Reviewer: XXL1, 29-Jan-2025 11:12:50
Page 5781 of 15442
Eurofins Pittsburgh
Data File: \\chromfs\Pittsburgh\ChromData\CHGC15\20250128-55352.b\0128250000048.D
Injection Date: 28-Jan-2025 23:57:03 Instrument ID: CHGC15
Lims ID: 180-185041-A-10-P Lab Sample ID: 180-185041-10
Client ID: #20250076 AMENDED COMPOSITE K
Operator ID: ALS Bottle#: 48 Worklist Smp#: 48
Injection Vol: 1.0 ul Dil. Factor: 20.0000
Method: IS PEST_CHGC15 Limit Group: GCS 8081B ICAL with IS
Column: MR-1 ( 0.53 mm) Detector GC ECD1A
16 Heptachlor epoxide, CAS: 1024-57-3, Signal: 1
RT: 5.60
Response: 498945
Amount: 0.000399
5.4 5.6 5.8 Min
RT
Y
X
Column: MR-2 ( 0.53 mm) Detector GC ECD2B
16 Heptachlor epoxide, CAS: 1024-57-3, Signal: 2
RT: 6.87
Response: 1161526
Amount: 0.000717
6.7 6.9 Min
RT
Y
X
Reviewer: XXL1, 29-Jan-2025 11:12:50
Page 5782 of 15442
Lab Name: Job No.: 180-185041-1Eurofins Pittsburgh
SDG No.:
Client Sample ID: #20250076 AMENDED
COMPOSITE K
Lab Sample ID: 180-185041-10
Matrix: 0115250000051.DLab File ID:
Date Collected:EPA 8081B LLAnalysis Method:
Sediment (SPLP East)
01/06/2025 10:41
Con. Extract Vol.:
Injection Volume:
GPC Cleanup:(Y/N)
Date Extracted:
Date Analyzed:
Dilution Factor: 1
Extraction Method: 3510C 01/14/2025 10:01
01/16/2025 02:46
1.0(mL)
1(uL)
Sample wt/vol: 1000(mL)
% Moisture:
GC Column: ID: 0.53(mm)MR-1
N% Solids:
Cleanup Factor:
Analysis Batch No.: 488337 ug/LUnits:
Preparation Batch No.: Instrument ID: 488242 CHGC15
CAS NO. COMPOUND NAME RESULT Q MDLRL
0.0013 0.00036U309-00-2 Aldrin 0.0013
0.0013 0.00024U319-84-6 alpha-BHC 0.0013
0.0013 0.00037U319-85-7 beta-BHC 0.0013
0.0013 0.00029U58-89-9 gamma-BHC (Lindane) 0.0013
0.0013 0.00037U5103-71-9 cis-Chlordane 0.0013
0.0013 0.00093U5103-74-2 trans-Chlordane 0.0013
0.013 0.0073U12789-03-6 Chlordane (technical) 0.013
0.0013 0.00053U72-54-8 4,4'-DDD 0.0013
0.0013 0.00072U72-55-9 4,4'-DDE 0.0013
0.0013 0.00069U50-29-3 4,4'-DDT 0.0013
0.0013 0.00027U60-57-1 Dieldrin 0.0013
0.0013 0.00069U959-98-8 Endosulfan I 0.0013
0.0013 0.00094U33213-65-9 Endosulfan II 0.0013
0.0013 0.00064U1031-07-8 Endosulfan sulfate 0.0013
0.0013 0.00023U72-20-8 Endrin 0.0013
0.0013 0.00045U76-44-8 Heptachlor 0.0013
0.0013 0.00034U1024-57-3 Heptachlor epoxide 0.0013
0.0013 0.00078U72-43-5 Methoxychlor 0.0013
0.0013 0.00047U2385-85-5 Mirex 0.0013
0.10 0.049U8001-35-2 Toxaphene 0.10
%RECCAS NO. LIMITSQSURROGATE
82 56-125877-09-8 Tetrachloro-m-xylene (Surr)
78 55-1282051-24-3 DCB Decachlorobiphenyl (Surr)
Page 5783 of 15442
Report Date: 17-Jan-2025 17:03:57 Chrom Revision: 2.3 17-Dec-2024 12:44:46
Target Compound Quantitation Report
Data File: \\chromfs\Pittsburgh\ChromData\CHGC15\20250115-55214.b\0115250000051.D
Lims ID: 180-185041-A-10-L
Client ID: #20250076 AMENDED COMPOSITE K
Sample Type: Client
Inject. Date: 16-Jan-2025 02:46:02 ALS Bottle#: 51 Worklist Smp#: 51
Injection Vol: 1.0 ul Dil. Factor: 1.0000
Sample Info: 180-0055214-051
Operator ID: Instrument ID: CHGC15
Method: \\chromfs\Pittsburgh\ChromData\CHGC15\20250115-55214.b\IS PEST_CHGC15.m
Limit Group: GCS 8081B ICAL with IS
Last Update: 17-Jan-2025 17:03:20 Calib Date: 28-May-2024 11:43:25
Integrator: Falcon
Quant Method: Internal Standard Quant By: Initial Calibration
Last ICal File: \\chromfs\Pittsburgh\ChromData\CHGC15\20240528-52583.b\0528240000008.D
Column 1 : MR-1 ( 0.53 mm) Det: GC ECD1A
Column 2 : MR-2 ( 0.53 mm) Det: GC ECD2B
Process Host: CTX1709
First Level Reviewer: XXL1 Date: 17-Jan-2025 16:58:53
Col
RT
(min.)
Exp RT (min.)
Dlt RT (min.) Response
OnCol Amt ng Flags
* 43 1-Bromo-2-nitrobenzene
1 2.642 2.645 -0.003 133467305H 0.1000
2 2.885 2.888 -0.003 234658611H 0.1000
$ 3 Tetrachloro-m-xylene
1 3.223 3.227 -0.004 13759756H 0.008183
2 3.718 3.719 -0.001 13598878H 0.004820
RPD = 51.72
5 alpha-BHC U
1 3.706 ND
2 4.399
7 gamma-BHC (Lindane) U
1 4.015 ND
2 4.859
8 beta-BHC U
1 4.100 ND
2 4.962
10 delta-BHC U
1 4.295 ND
2 5.393
Page 5784 of 15442
Data File: \\chromfs\Pittsburgh\ChromData\CHGC15\20250115-55214.b\0115250000051.D
Col
RT
(min.)
Exp RT (min.)
Dlt RT (min.) Response
OnCol Amt ng Flags
9 Chlordane (technical)
1 4.443 ND
1 4.538
1 5.906
1 6.094
2 5.512
2 7.366
2 7.557
2 7.656
11 Heptachlor
1 4.538 ND
2 5.509
13 Aldrin 7
1 4.902 ND
2 6.026
16 Heptachlor epoxide 7
1 5.717 ND
2 7.008
18 trans-Chlordane U
1 5.905 ND
2 7.366
20 cis-Chlordane
1 6.110 ND
2 7.655
23 4,4'-DDE U
1 6.264 ND
2 8.030
21 Endosulfan I U
1 6.315 ND
2 7.764
24 Dieldrin
1 6.708 ND
2 8.321
27 Endrin U
1 7.100 ND
2 8.888
29 4,4'-DDD
1 7.287 ND
2 9.138
31 Endosulfan II
1 7.501 ND
2 9.269
Page 5785 of 15442
Col
RT
(min.)
Exp RT (min.)
Dlt RT (min.) Response
OnCol Amt ng Flags
34 Toxaphene
1 7.731 ND
1 8.293
1 8.931
1 9.541
2 9.419
2 9.865
2 10.652
2 11.231
33 4,4'-DDT
1 7.832 ND
2 9.675
36 Methoxychlor 7
1 8.825 ND
2 10.772
38 Mirex
1 8.925 ND
2 11.024
35 Endosulfan sulfate U
1 9.099 ND
2 10.288
* 61 PCB-205 (IS)
1 10.582 10.584 -0.002 138816013H 0.1000
2 12.061 12.062 -0.001 204829214H 0.1000
* 44 Dibutylchlorendate ISTD
1 10.956 ND
2 12.203
$ 39 DCB Decachlorobiphenyl (Surr)
1 11.194 11.196 -0.002 9435012H 0.007813
2 12.776 12.777 -0.001 14334824H 0.008627
RPD = 9.90
S 62 Endosulfan, Total
1 0.000 ND
QC Flag Legend Processing Flags
7 - Failed Limit of Detection
H - Response Measured by Height
Review Flags
U - Marked Undetected
Reagents:
PCBINT_00032 Amount Added: 0.01 Units: mL Run Reagent
Page 5786 of 15442
Data File: \\chromfs\Pittsburgh\ChromData\CHGC15\20250115-55214.b\0115250000051.D
Injection Date: 16-Jan-2025 02:46:02 Instrument ID: CHGC15 Operator ID:
Lims ID: 180-185041-A-10-L Lab Sample ID: 180-185041-10 Worklist Smp#: 51
Client ID: #20250076 AMENDED COMPOSITE K
Injection Vol: 1.0 ul Dil. Factor: 1.0000 ALS Bottle#: 51
Method: IS PEST_CHGC15 Limit Group: GCS 8081B ICAL with IS
Column: MR-1 ( 0.53 mm)
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0 13.0 14.0 15.0 Min
Y
X
GC ECD1A, 0115250000051.D
-B ro m o
-2 -n it ro b e n z e n e
.6
T e tr a c h lo ro
-m -x y le n e
.2
P
C B
-2
IS
.5
D
C B
D e c a c h lo ro b ip h e n y l (S u rr
.1
Column: MR-2 ( 0.53 mm)
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0 13.0 14.0 15.0 Min
Y
X
GC ECD2B, 0115250000051.D
-B ro m o
-2 -n it ro b e n z e n e
.8
T e tr a c h lo ro
-m -x y le n e
.7
P
C B
-2
IS
.0
D
C B
D e c a c h lo ro b ip h e n y l (S u rr
.7
Page 5787 of 15442
Recovery Report
Data File: \\chromfs\Pittsburgh\ChromData\CHGC15\20250115-55214.b\0115250000051.D
Lims ID: 180-185041-A-10-L
Client ID: #20250076 AMENDED COMPOSITE K
Sample Type: Client
Inject. Date: 16-Jan-2025 02:46:02 ALS Bottle#: 51 Worklist Smp#: 51
Injection Vol: 1.0 ul Dil. Factor: 1.0000
Sample Info: 180-0055214-051
Operator ID: Instrument ID: CHGC15
Method: \\chromfs\Pittsburgh\ChromData\CHGC15\20250115-55214.b\IS PEST_CHGC15.m
Limit Group: GCS 8081B ICAL with IS
Last Update: 17-Jan-2025 17:03:20 Calib Date: 28-May-2024 11:43:25
Integrator: Falcon
Quant Method: Internal Standard Quant By: Initial Calibration
Last ICal File: \\chromfs\Pittsburgh\ChromData\CHGC15\20240528-52583.b\0528240000008.D
Column 1 : MR-1 ( 0.53 mm) Det: GC ECD1A
Column 2 : MR-2 ( 0.53 mm) Det: GC ECD2B
Process Host: CTX1709
First Level Reviewer: XXL1 Date: 17-Jan-2025 16:58:53
Surrogate Recovery, Detector: GC ECD1A
Compound Amount Added
Amount Recovered % Rec.
$ 3 Tetrachloro-m-xylene 0.0200 0.008183 40.91
$ 39 DCB Decachlorobiphenyl (Surr) 0.0200 0.007813 39.07
Surrogate Recovery, Detector: GC ECD2B
Compound Amount Added
Amount Recovered % Rec.
$ 3 Tetrachloro-m-xylene 0.0200 0.004820 24.10
$ 39 DCB Decachlorobiphenyl (Surr) 0.0200 0.008627 43.13
Page 5788 of 15442
Eurofins Pittsburgh
Data File: \\chromfs\Pittsburgh\ChromData\CHGC15\20250115-55214.b\0115250000051.D
Injection Date: 16-Jan-2025 02:46:02 Instrument ID: CHGC15
Lims ID: 180-185041-A-10-L Lab Sample ID: 180-185041-10
Client ID: #20250076 AMENDED COMPOSITE K
Operator ID: ALS Bottle#: 51 Worklist Smp#: 51
Injection Vol: 1.0 ul Dil. Factor: 1.0000
Method: IS PEST_CHGC15 Limit Group: GCS 8081B ICAL with IS
Column: MR-1 ( 0.53 mm) Detector GC ECD1A
5 alpha-BHC, CAS: 319-84-6, Signal: 1
RT: 3.68
Response: 5339690
Amount: 0.002261
3.5 3.7 Min
RT
Y
X
GC ECD1A, 0115250000051.D
Column: MR-2 ( 0.53 mm) Detector GC ECD2B
5 alpha-BHC, CAS: 319-84-6, Signal: 2
RT: 4.40
Response: 76286109
Amount: 0.020544
4.2 4.4 4.6 Min
RT
Y
X
GC ECD2B, 0115250000051.D
.4
Reviewer: XXL1, 17-Jan-2025 16:58:53
Page 5789 of 15442
Eurofins Pittsburgh
Data File: \\chromfs\Pittsburgh\ChromData\CHGC15\20250115-55214.b\0115250000051.D
Injection Date: 16-Jan-2025 02:46:02 Instrument ID: CHGC15
Lims ID: 180-185041-A-10-L Lab Sample ID: 180-185041-10
Client ID: #20250076 AMENDED COMPOSITE K
Operator ID: ALS Bottle#: 51 Worklist Smp#: 51
Injection Vol: 1.0 ul Dil. Factor: 1.0000
Method: IS PEST_CHGC15 Limit Group: GCS 8081B ICAL with IS
Column: MR-1 ( 0.53 mm) Detector GC ECD1A
8 beta-BHC, CAS: 319-85-7, Signal: 1
RT: 4.11
Response: 44042365
Amount: 0.051509
3.9 4.1 4.3 Min
RT
Y
X
.1
Column: MR-2 ( 0.53 mm) Detector GC ECD2B
8 beta-BHC, CAS: 319-85-7, Signal: 2
RT: 4.96
Response: 331930
Amount: 0.000236
4.8 5.0 Min
RT
Y
X
Reviewer: XXL1, 17-Jan-2025 16:58:53
Page 5790 of 15442
Eurofins Pittsburgh
Data File: \\chromfs\Pittsburgh\ChromData\CHGC15\20250115-55214.b\0115250000051.D
Injection Date: 16-Jan-2025 02:46:02 Instrument ID: CHGC15
Lims ID: 180-185041-A-10-L Lab Sample ID: 180-185041-10
Client ID: #20250076 AMENDED COMPOSITE K
Operator ID: ALS Bottle#: 51 Worklist Smp#: 51
Injection Vol: 1.0 ul Dil. Factor: 1.0000
Method: IS PEST_CHGC15 Limit Group: GCS 8081B ICAL with IS
Column: MR-1 ( 0.53 mm) Detector GC ECD1A
7 gamma-BHC (Lindane), CAS: 58-89-9, Signal: 1
RT: 4.02
Response: 12695638
Amount: 0.006446
3.9 4.1 Min
RT
Y
X
Column: MR-2 ( 0.53 mm) Detector GC ECD2B
7 gamma-BHC (Lindane), CAS: 58-89-9, Signal: 2
RT: 4.84
Response: 18008064
Amount: 0.005777
4.7 4.9 Min
RT
Y
X
Reviewer: XXL1, 17-Jan-2025 16:58:53
Page 5791 of 15442
Eurofins Pittsburgh
Data File: \\chromfs\Pittsburgh\ChromData\CHGC15\20250115-55214.b\0115250000051.D
Injection Date: 16-Jan-2025 02:46:02 Instrument ID: CHGC15
Lims ID: 180-185041-A-10-L Lab Sample ID: 180-185041-10
Client ID: #20250076 AMENDED COMPOSITE K
Operator ID: ALS Bottle#: 51 Worklist Smp#: 51
Injection Vol: 1.0 ul Dil. Factor: 1.0000
Method: IS PEST_CHGC15 Limit Group: GCS 8081B ICAL with IS
Column: MR-1 ( 0.53 mm) Detector GC ECD1A
18 trans-Chlordane, CAS: 5103-74-2, Signal: 1
RT: 5.89
Response: 13265957
Amount: 0.010371
5.7 5.9 6.1 Min
RT
Y
X
Column: MR-2 ( 0.53 mm) Detector GC ECD2B
18 trans-Chlordane, CAS: 5103-74-2, Signal: 2
RT: 7.36
Response: 893668
Amount: 0.000438
7.2 7.4 Min
RT
Y
X
Reviewer: XXL1, 17-Jan-2025 16:58:53
Page 5792 of 15442
Eurofins Pittsburgh
Data File: \\chromfs\Pittsburgh\ChromData\CHGC15\20250115-55214.b\0115250000051.D
Injection Date: 16-Jan-2025 02:46:02 Instrument ID: CHGC15
Lims ID: 180-185041-A-10-L Lab Sample ID: 180-185041-10
Client ID: #20250076 AMENDED COMPOSITE K
Operator ID: ALS Bottle#: 51 Worklist Smp#: 51
Injection Vol: 1.0 ul Dil. Factor: 1.0000
Method: IS PEST_CHGC15 Limit Group: GCS 8081B ICAL with IS
Column: MR-1 ( 0.53 mm) Detector GC ECD1A
23 4,4'-DDE, CAS: 72-55-9, Signal: 1
RT: 6.25
Response: 677962
Amount: 0.000471
6.1 6.3 Min
RT
Y
X
Column: MR-2 ( 0.53 mm) Detector GC ECD2B
23 4,4'-DDE, CAS: 72-55-9, Signal: 2
RT: 8.02
Response: 3743192
Amount: 0.002045
7.8 8.0 8.2 Min
RT
Y
X
Reviewer: XXL1, 17-Jan-2025 16:58:53
Page 5793 of 15442
Eurofins Pittsburgh
Data File: \\chromfs\Pittsburgh\ChromData\CHGC15\20250115-55214.b\0115250000051.D
Injection Date: 16-Jan-2025 02:46:02 Instrument ID: CHGC15
Lims ID: 180-185041-A-10-L Lab Sample ID: 180-185041-10
Client ID: #20250076 AMENDED COMPOSITE K
Operator ID: ALS Bottle#: 51 Worklist Smp#: 51
Injection Vol: 1.0 ul Dil. Factor: 1.0000
Method: IS PEST_CHGC15 Limit Group: GCS 8081B ICAL with IS
Column: MR-1 ( 0.53 mm) Detector GC ECD1A
21 Endosulfan I, CAS: 959-98-8, Signal: 1
RT: 6.31
Response: 572158
Amount: 0.000528
6.2 6.4 Min
RT
Y
X
Column: MR-2 ( 0.53 mm) Detector GC ECD2B
21 Endosulfan I, CAS: 959-98-8, Signal: 2
RT: 7.77
Response: 356882
Amount: 0.000194
7.6 7.8 Min
RT
Y
X
Reviewer: XXL1, 17-Jan-2025 16:58:53
Page 5794 of 15442
Eurofins Pittsburgh
Data File: \\chromfs\Pittsburgh\ChromData\CHGC15\20250115-55214.b\0115250000051.D
Injection Date: 16-Jan-2025 02:46:02 Instrument ID: CHGC15
Lims ID: 180-185041-A-10-L Lab Sample ID: 180-185041-10
Client ID: #20250076 AMENDED COMPOSITE K
Operator ID: ALS Bottle#: 51 Worklist Smp#: 51
Injection Vol: 1.0 ul Dil. Factor: 1.0000
Method: IS PEST_CHGC15 Limit Group: GCS 8081B ICAL with IS
Column: MR-1 ( 0.53 mm) Detector GC ECD1A
35 Endosulfan sulfate, CAS: 1031-07-8, Signal: 1
RT: 9.11
Response: 904155
Amount: 0.000753
8.9 9.1 9.3 Min
RT
Y
X
Column: MR-2 ( 0.53 mm) Detector GC ECD2B
35 Endosulfan sulfate, CAS: 1031-07-8, Signal: 2
RT: 10.29
Response: 340813
Amount: 0.000222
10.1 10.3 Min
RT
Y
X
GC ECD2B, 0115250000051.D
.2
Reviewer: XXL1, 17-Jan-2025 16:58:53
Page 5795 of 15442
Eurofins Pittsburgh
Data File: \\chromfs\Pittsburgh\ChromData\CHGC15\20250115-55214.b\0115250000051.D
Injection Date: 16-Jan-2025 02:46:02 Instrument ID: CHGC15
Lims ID: 180-185041-A-10-L Lab Sample ID: 180-185041-10
Client ID: #20250076 AMENDED COMPOSITE K
Operator ID: ALS Bottle#: 51 Worklist Smp#: 51
Injection Vol: 1.0 ul Dil. Factor: 1.0000
Method: IS PEST_CHGC15 Limit Group: GCS 8081B ICAL with IS
Column: MR-1 ( 0.53 mm) Detector GC ECD1A
27 Endrin, CAS: 72-20-8, Signal: 1
RT: 7.10
Response: 462304
Amount: 0.000409
7.0 7.2 Min
RT
Y
X
Column: MR-2 ( 0.53 mm) Detector GC ECD2B
27 Endrin, CAS: 72-20-8, Signal: 2
RT: 8.90
Response: 828850
Amount: 0.000517
8.8 9.0 Min
RT
Y
X
Reviewer: XXL1, 17-Jan-2025 16:58:53
Page 5796 of 15442
Lab Name: Job No.: 180-185041-1Eurofins Pittsburgh
SDG No.:
Client Sample ID: #20250076 AMENDED
COMPOSITE K
Lab Sample ID: 180-185041-10
Matrix: 0115250000051.DLab File ID:
Date Collected:EPA 8081B LLAnalysis Method:
Sediment (SPLP East)
01/06/2025 10:41
Con. Extract Vol.:
Injection Volume:
GPC Cleanup:(Y/N)
Date Extracted:
Date Analyzed:
Dilution Factor: 1
Extraction Method: 3510C 01/14/2025 10:01
01/16/2025 02:46
1.0(mL)
1(uL)
Sample wt/vol: 1000(mL)
% Moisture:
GC Column: ID: 0.53(mm)MR-2
N% Solids:
Cleanup Factor:
Analysis Batch No.: 488337 ug/LUnits:
Preparation Batch No.: Instrument ID: 488242 CHGC15
%RECCAS NO. LIMITSQSURROGATE
p S1-48 56-125877-09-8 Tetrachloro-m-xylene (Surr)
86 55-1282051-24-3 DCB Decachlorobiphenyl (Surr)
Page 5797 of 15442
Target Compound Quantitation Report
Data File: \\chromfs\Pittsburgh\ChromData\CHGC15\20250115-55214.b\0115250000051.D
Lims ID: 180-185041-A-10-L
Client ID: #20250076 AMENDED COMPOSITE K
Sample Type: Client
Inject. Date: 16-Jan-2025 02:46:02 ALS Bottle#: 51 Worklist Smp#: 51
Injection Vol: 1.0 ul Dil. Factor: 1.0000
Sample Info: 180-0055214-051
Operator ID: Instrument ID: CHGC15
Method: \\chromfs\Pittsburgh\ChromData\CHGC15\20250115-55214.b\IS PEST_CHGC15.m
Limit Group: GCS 8081B ICAL with IS
Last Update: 17-Jan-2025 17:03:20 Calib Date: 28-May-2024 11:43:25
Integrator: Falcon
Quant Method: Internal Standard Quant By: Initial Calibration
Last ICal File: \\chromfs\Pittsburgh\ChromData\CHGC15\20240528-52583.b\0528240000008.D
Column 1 : MR-1 ( 0.53 mm) Det: GC ECD1A
Column 2 : MR-2 ( 0.53 mm) Det: GC ECD2B
Process Host: CTX1709
First Level Reviewer: XXL1 Date: 17-Jan-2025 16:58:53
Col
RT
(min.)
Exp RT (min.)
Dlt RT (min.) Response
OnCol Amt ng Flags
* 43 1-Bromo-2-nitrobenzene
1 2.642 2.645 -0.003 133467305H 0.1000
2 2.885 2.888 -0.003 234658611H 0.1000
$ 3 Tetrachloro-m-xylene
1 3.223 3.227 -0.004 13759756H 0.008183
2 3.718 3.719 -0.001 13598878H 0.004820
RPD = 51.72
5 alpha-BHC U
1 3.706 ND
2 4.399
7 gamma-BHC (Lindane) U
1 4.015 ND
2 4.859
8 beta-BHC U
1 4.100 ND
2 4.962
10 delta-BHC U
1 4.295 ND
2 5.393
Page 5798 of 15442
Col
RT
(min.)
Exp RT (min.)
Dlt RT (min.) Response
OnCol Amt ng Flags
9 Chlordane (technical)
1 4.443 ND
1 4.538
1 5.906
1 6.094
2 5.512
2 7.366
2 7.557
2 7.656
11 Heptachlor
1 4.538 ND
2 5.509
13 Aldrin 7
1 4.902 ND
2 6.026
16 Heptachlor epoxide 7
1 5.717 ND
2 7.008
18 trans-Chlordane U
1 5.905 ND
2 7.366
20 cis-Chlordane
1 6.110 ND
2 7.655
23 4,4'-DDE U
1 6.264 ND
2 8.030
21 Endosulfan I U
1 6.315 ND
2 7.764
24 Dieldrin
1 6.708 ND
2 8.321
27 Endrin U
1 7.100 ND
2 8.888
29 4,4'-DDD
1 7.287 ND
2 9.138
31 Endosulfan II
1 7.501 ND
2 9.269
Page 5799 of 15442
Col
RT
(min.)
Exp RT (min.)
Dlt RT (min.) Response
OnCol Amt ng Flags
34 Toxaphene
1 7.731 ND
1 8.293
1 8.931
1 9.541
2 9.419
2 9.865
2 10.652
2 11.231
33 4,4'-DDT
1 7.832 ND
2 9.675
36 Methoxychlor 7
1 8.825 ND
2 10.772
38 Mirex
1 8.925 ND
2 11.024
35 Endosulfan sulfate U
1 9.099 ND
2 10.288
* 61 PCB-205 (IS)
1 10.582 10.584 -0.002 138816013H 0.1000
2 12.061 12.062 -0.001 204829214H 0.1000
* 44 Dibutylchlorendate ISTD
1 10.956 ND
2 12.203
$ 39 DCB Decachlorobiphenyl (Surr)
1 11.194 11.196 -0.002 9435012H 0.007813
2 12.776 12.777 -0.001 14334824H 0.008627
RPD = 9.90
S 62 Endosulfan, Total
1 0.000 ND
QC Flag Legend Processing Flags
7 - Failed Limit of Detection
H - Response Measured by Height
Review Flags
U - Marked Undetected
Reagents:
PCBINT_00032 Amount Added: 0.01 Units: mL Run Reagent
Page 5800 of 15442
Data File: \\chromfs\Pittsburgh\ChromData\CHGC15\20250115-55214.b\0115250000051.D
Injection Date: 16-Jan-2025 02:46:02 Instrument ID: CHGC15 Operator ID:
Lims ID: 180-185041-A-10-L Lab Sample ID: 180-185041-10 Worklist Smp#: 51
Client ID: #20250076 AMENDED COMPOSITE K
Injection Vol: 1.0 ul Dil. Factor: 1.0000 ALS Bottle#: 51
Method: IS PEST_CHGC15 Limit Group: GCS 8081B ICAL with IS
Column: MR-1 ( 0.53 mm)
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0 13.0 14.0 15.0 Min
Y
X
GC ECD1A, 0115250000051.D
-B ro m o
-2 -n it ro b e n z e n e
.6
T e tr a c h lo ro
-m -x y le n e
.2
P
C B
-2
IS
.5
D
C B
D e c a c h lo ro b ip h e n y l (S u rr
.1
Column: MR-2 ( 0.53 mm)
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0 13.0 14.0 15.0 Min
Y
X
GC ECD2B, 0115250000051.D
-B ro m o
-2 -n it ro b e n z e n e
.8
T e tr a c h lo ro
-m -x y le n e
.7
P
C B
-2
IS
.0
D
C B
D e c a c h lo ro b ip h e n y l (S u rr
.7
Page 5801 of 15442
Recovery Report
Data File: \\chromfs\Pittsburgh\ChromData\CHGC15\20250115-55214.b\0115250000051.D
Lims ID: 180-185041-A-10-L
Client ID: #20250076 AMENDED COMPOSITE K
Sample Type: Client
Inject. Date: 16-Jan-2025 02:46:02 ALS Bottle#: 51 Worklist Smp#: 51
Injection Vol: 1.0 ul Dil. Factor: 1.0000
Sample Info: 180-0055214-051
Operator ID: Instrument ID: CHGC15
Method: \\chromfs\Pittsburgh\ChromData\CHGC15\20250115-55214.b\IS PEST_CHGC15.m
Limit Group: GCS 8081B ICAL with IS
Last Update: 17-Jan-2025 17:03:20 Calib Date: 28-May-2024 11:43:25
Integrator: Falcon
Quant Method: Internal Standard Quant By: Initial Calibration
Last ICal File: \\chromfs\Pittsburgh\ChromData\CHGC15\20240528-52583.b\0528240000008.D
Column 1 : MR-1 ( 0.53 mm) Det: GC ECD1A
Column 2 : MR-2 ( 0.53 mm) Det: GC ECD2B
Process Host: CTX1709
First Level Reviewer: XXL1 Date: 17-Jan-2025 16:58:53
Surrogate Recovery, Detector: GC ECD1A
Compound Amount Added
Amount Recovered % Rec.
$ 3 Tetrachloro-m-xylene 0.0200 0.008183 40.91
$ 39 DCB Decachlorobiphenyl (Surr) 0.0200 0.007813 39.07
Surrogate Recovery, Detector: GC ECD2B
Compound Amount Added
Amount Recovered % Rec.
$ 3 Tetrachloro-m-xylene 0.0200 0.004820 24.10
$ 39 DCB Decachlorobiphenyl (Surr) 0.0200 0.008627 43.13
Page 5802 of 15442
Report Date: 17-Jan-2025 17:03:58 Chrom Revision: 2.3 17-Dec-2024 12:44:46
Eurofins Pittsburgh
Data File: \\chromfs\Pittsburgh\ChromData\CHGC15\20250115-55214.b\0115250000051.D
Injection Date: 16-Jan-2025 02:46:02 Instrument ID: CHGC15
Lims ID: 180-185041-A-10-L Lab Sample ID: 180-185041-10
Client ID: #20250076 AMENDED COMPOSITE K
Operator ID: ALS Bottle#: 51 Worklist Smp#: 51
Injection Vol: 1.0 ul Dil. Factor: 1.0000
Method: IS PEST_CHGC15 Limit Group: GCS 8081B ICAL with IS
Column: MR-1 ( 0.53 mm) Detector GC ECD1A
5 alpha-BHC, CAS: 319-84-6, Signal: 1
RT: 3.68
Response: 5339690
Amount: 0.002261
3.5 3.7 Min
RT
Y
X
Column: MR-2 ( 0.53 mm) Detector GC ECD2B
5 alpha-BHC, CAS: 319-84-6, Signal: 2
RT: 4.40
Response: 76286109
Amount: 0.020544
4.2 4.4 4.6 Min
RT
Y
X
.4
Reviewer: XXL1, 17-Jan-2025 16:58:53
Page 5803 of 15442
Eurofins Pittsburgh
Data File: \\chromfs\Pittsburgh\ChromData\CHGC15\20250115-55214.b\0115250000051.D
Injection Date: 16-Jan-2025 02:46:02 Instrument ID: CHGC15
Lims ID: 180-185041-A-10-L Lab Sample ID: 180-185041-10
Client ID: #20250076 AMENDED COMPOSITE K
Operator ID: ALS Bottle#: 51 Worklist Smp#: 51
Injection Vol: 1.0 ul Dil. Factor: 1.0000
Method: IS PEST_CHGC15 Limit Group: GCS 8081B ICAL with IS
Column: MR-1 ( 0.53 mm) Detector GC ECD1A
8 beta-BHC, CAS: 319-85-7, Signal: 1
RT: 4.11
Response: 44042365
Amount: 0.051509
3.9 4.1 4.3 Min
RT
Y
X
Column: MR-2 ( 0.53 mm) Detector GC ECD2B
8 beta-BHC, CAS: 319-85-7, Signal: 2
RT: 4.96
Response: 331930
Amount: 0.000236
4.8 5.0 Min
RT
Y
X
Reviewer: XXL1, 17-Jan-2025 16:58:53
Page 5804 of 15442
Eurofins Pittsburgh
Data File: \\chromfs\Pittsburgh\ChromData\CHGC15\20250115-55214.b\0115250000051.D
Injection Date: 16-Jan-2025 02:46:02 Instrument ID: CHGC15
Lims ID: 180-185041-A-10-L Lab Sample ID: 180-185041-10
Client ID: #20250076 AMENDED COMPOSITE K
Operator ID: ALS Bottle#: 51 Worklist Smp#: 51
Injection Vol: 1.0 ul Dil. Factor: 1.0000
Method: IS PEST_CHGC15 Limit Group: GCS 8081B ICAL with IS
Column: MR-1 ( 0.53 mm) Detector GC ECD1A
7 gamma-BHC (Lindane), CAS: 58-89-9, Signal: 1
RT: 4.02
Response: 12695638
Amount: 0.006446
3.9 4.1 Min
RT
Y
X
Column: MR-2 ( 0.53 mm) Detector GC ECD2B
7 gamma-BHC (Lindane), CAS: 58-89-9, Signal: 2
RT: 4.84
Response: 18008064
Amount: 0.005777
4.7 4.9 Min
RT
Y
X
Reviewer: XXL1, 17-Jan-2025 16:58:53
Page 5805 of 15442
Eurofins Pittsburgh
Data File: \\chromfs\Pittsburgh\ChromData\CHGC15\20250115-55214.b\0115250000051.D
Injection Date: 16-Jan-2025 02:46:02 Instrument ID: CHGC15
Lims ID: 180-185041-A-10-L Lab Sample ID: 180-185041-10
Client ID: #20250076 AMENDED COMPOSITE K
Operator ID: ALS Bottle#: 51 Worklist Smp#: 51
Injection Vol: 1.0 ul Dil. Factor: 1.0000
Method: IS PEST_CHGC15 Limit Group: GCS 8081B ICAL with IS
Column: MR-1 ( 0.53 mm) Detector GC ECD1A
18 trans-Chlordane, CAS: 5103-74-2, Signal: 1
RT: 5.89
Response: 13265957
Amount: 0.010371
5.7 5.9 6.1 Min
RT
Y
X
Column: MR-2 ( 0.53 mm) Detector GC ECD2B
18 trans-Chlordane, CAS: 5103-74-2, Signal: 2
RT: 7.36
Response: 893668
Amount: 0.000438
7.2 7.4 Min
RT
Y
X
Reviewer: XXL1, 17-Jan-2025 16:58:53
Page 5806 of 15442
Eurofins Pittsburgh
Data File: \\chromfs\Pittsburgh\ChromData\CHGC15\20250115-55214.b\0115250000051.D
Injection Date: 16-Jan-2025 02:46:02 Instrument ID: CHGC15
Lims ID: 180-185041-A-10-L Lab Sample ID: 180-185041-10
Client ID: #20250076 AMENDED COMPOSITE K
Operator ID: ALS Bottle#: 51 Worklist Smp#: 51
Injection Vol: 1.0 ul Dil. Factor: 1.0000
Method: IS PEST_CHGC15 Limit Group: GCS 8081B ICAL with IS
Column: MR-1 ( 0.53 mm) Detector GC ECD1A
23 4,4'-DDE, CAS: 72-55-9, Signal: 1
RT: 6.25
Response: 677962
Amount: 0.000471
6.1 6.3 Min
RT
Y
X
Column: MR-2 ( 0.53 mm) Detector GC ECD2B
23 4,4'-DDE, CAS: 72-55-9, Signal: 2
RT: 8.02
Response: 3743192
Amount: 0.002045
7.8 8.0 8.2 Min
RT
Y
X
Reviewer: XXL1, 17-Jan-2025 16:58:53
Page 5807 of 15442
Eurofins Pittsburgh
Data File: \\chromfs\Pittsburgh\ChromData\CHGC15\20250115-55214.b\0115250000051.D
Injection Date: 16-Jan-2025 02:46:02 Instrument ID: CHGC15
Lims ID: 180-185041-A-10-L Lab Sample ID: 180-185041-10
Client ID: #20250076 AMENDED COMPOSITE K
Operator ID: ALS Bottle#: 51 Worklist Smp#: 51
Injection Vol: 1.0 ul Dil. Factor: 1.0000
Method: IS PEST_CHGC15 Limit Group: GCS 8081B ICAL with IS
Column: MR-1 ( 0.53 mm) Detector GC ECD1A
21 Endosulfan I, CAS: 959-98-8, Signal: 1
RT: 6.31
Response: 572158
Amount: 0.000528
6.2 6.4 Min
RT
Y
X
Column: MR-2 ( 0.53 mm) Detector GC ECD2B
21 Endosulfan I, CAS: 959-98-8, Signal: 2
RT: 7.77
Response: 356882
Amount: 0.000194
7.6 7.8 Min
RT
Y
X
Reviewer: XXL1, 17-Jan-2025 16:58:53
Page 5808 of 15442
Eurofins Pittsburgh
Data File: \\chromfs\Pittsburgh\ChromData\CHGC15\20250115-55214.b\0115250000051.D
Injection Date: 16-Jan-2025 02:46:02 Instrument ID: CHGC15
Lims ID: 180-185041-A-10-L Lab Sample ID: 180-185041-10
Client ID: #20250076 AMENDED COMPOSITE K
Operator ID: ALS Bottle#: 51 Worklist Smp#: 51
Injection Vol: 1.0 ul Dil. Factor: 1.0000
Method: IS PEST_CHGC15 Limit Group: GCS 8081B ICAL with IS
Column: MR-1 ( 0.53 mm) Detector GC ECD1A
35 Endosulfan sulfate, CAS: 1031-07-8, Signal: 1
RT: 9.11
Response: 904155
Amount: 0.000753
8.9 9.1 9.3 Min
RT
Y
X
Column: MR-2 ( 0.53 mm) Detector GC ECD2B
35 Endosulfan sulfate, CAS: 1031-07-8, Signal: 2
RT: 10.29
Response: 340813
Amount: 0.000222
10.1 10.3 Min
RT
Y
X
GC ECD2B, 0115250000051.D
.2
Reviewer: XXL1, 17-Jan-2025 16:58:53
Page 5809 of 15442
Eurofins Pittsburgh
Data File: \\chromfs\Pittsburgh\ChromData\CHGC15\20250115-55214.b\0115250000051.D
Injection Date: 16-Jan-2025 02:46:02 Instrument ID: CHGC15
Lims ID: 180-185041-A-10-L Lab Sample ID: 180-185041-10
Client ID: #20250076 AMENDED COMPOSITE K
Operator ID: ALS Bottle#: 51 Worklist Smp#: 51
Injection Vol: 1.0 ul Dil. Factor: 1.0000
Method: IS PEST_CHGC15 Limit Group: GCS 8081B ICAL with IS
Column: MR-1 ( 0.53 mm) Detector GC ECD1A
27 Endrin, CAS: 72-20-8, Signal: 1
RT: 7.10
Response: 462304
Amount: 0.000409
7.0 7.2 Min
RT
Y
X
Column: MR-2 ( 0.53 mm) Detector GC ECD2B
27 Endrin, CAS: 72-20-8, Signal: 2
RT: 8.90
Response: 828850
Amount: 0.000517
8.8 9.0 Min
RT
Y
X
Reviewer: XXL1, 17-Jan-2025 16:58:53
Page 5810 of 15442
FORM VI
Lab Name: Job No.:
PESTICIDES BY INTERNAL STANDARD - INITIAL CALIBRATION DATA
Eurofins Pittsburgh 180-185041-1 Analy Batch No.: 469565
CURVE EVALUATION
SDG No.:
Calibration ID:
Instrument ID: GC Column: Heated Purge: (Y/N)CHGC15
52510Calibration Start Date: Calibration End Date:05/23/2024 12:28
N
05/23/2024 13:45
0.53(mm)MR-1 ID:
Calibration Files
LEVEL: LAB SAMPLE ID: LAB FILE ID:
1Level IC 180-469565/2 0507240000011.D 2Level IC 180-469565/3 0507240000012.D 3Level IC 180-469565/4 0507240000013.D 4Level IC 180-469565/5 0507240000014.D 5Level IC 180-469565/6 0507240000015.D
ANALYTE RRF
LVL 1 LVL 2 LVL 3 LVL 4 LVL 5
CURVE
TYPE
COEFFICIENT
B M1 M2
# %RSD # MAX
%RSD
R^2
OR COD
# MIN R^2
OR COD
MIN RRF
/RSE
/RSE
Toxaphene Peak 1 0.0101 0.0105 0.0109 0.0108 0.0108 Ave 3.0 20.00.0106
Toxaphene Peak 2 0.0140 0.0139 0.0148 0.0148 0.0144 Ave 3.0 20.00.0144
Toxaphene Peak 3 0.0210 0.0205 0.0215 0.0211 0.0207 Ave 1.8 20.00.0210
Toxaphene Peak 4 0.0140 0.0139 0.0142 0.0142 0.0145 Ave 1.8 20.00.0142
FORM VI EPA 8081B LL
Note: The M1 coefficient is the same as Ave RRF for an Ave curve type. RSD is calculated for Ave curve types. RSE is used for all other types.
Page 5811 of 15442
PESTICIDES BY INTERNAL STANDARD - INITIAL CALIBRATION DATA
Eurofins Pittsburgh 180-185041-1 Analy Batch No.: 469565
RESPONSE AND CONCENTRATION
SDG No.:
Calibration ID:
Instrument ID: Heated Purge: (Y/N)CHGC15
52510Calibration Start Date: Calibration End Date:05/23/2024 12:28
N
05/23/2024 13:45
GC Column: MR-1 ID: 0.53(mm)
Calibration Files:
LEVEL: LAB SAMPLE ID: LAB FILE ID:
Level 1 IC 180-469565/2 0507240000011.D Level 2 IC 180-469565/3 0507240000012.D Level 3 IC 180-469565/4 0507240000013.D Level 4 IC 180-469565/5 0507240000014.D Level 5 IC 180-469565/6 0507240000015.D
ANALYTE CURVE
TYPE
IS
REF
RESPONSE
LVL 1 LVL 2 LVL 3…