4-STRUCT_A W_100__NPS_4-28-2016_-_modified_drwgs_only.pdf
PDF 2 MB Posted
- Attached to
- Green Brook Segment B3 Federal contract opportunity
- Solicitation number
- W912DS-16-B-0007
About this file
NPS
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| W912DS-16-B-0007_Bid_Abstract.pdf | ||
| W912DS-16-B-00070009.PDF | ||
| W912DS-16-B-00070008.pdf | ||
| 16-0258.pdf | ||
| W912DS-16-B-00070007.pdf | ||
| W912DS-16-B-00070006.pdf | ||
| W912DS-16-B-00070005.pdf | ||
| W912DS-16-B-00070004.pdf | ||
| W912DS-16-B-0007-0003.pdf | ||
| W912DS-16-B-0007-Amendment_0002.pdf | ||
| GB_SEG_B3_SS709WCB_REV1.pdf | ||
| GB_SEG_B3_C-503WCB_REV1.pdf | ||
| W912DS-16-B-0007-Amendment_0001.pdf | ||
| GB_SEG_B3_C-501WCB_REV1.pdf | ||
| GB_SEG_B3_SB101WCB_REV1.pdf | ||
| GB_SEG_B3_C-102WCB_REV1.pdf | ||
| EM_1110-2-6056.pdf | ||
| GB_SEG_B3_C-101WCB_REV1.pdf | ||
| GB_SEG_B3_C-104WCB_REV1.pdf | ||
| final-report-URS-geotech.pdf | ||
| Specifications_-_B3_100__NPS_4-12-2016.pdf | ||
| Segment_B3_(NPS)_Drawings_-_4-15-2016.pdf | ||
| W912DS-16-B-0007.pdf |
Show all 23
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PUMP STATION
12.
11.
10.
9.
8.
7.
6.
5.
4.
3.
2.
1. 11.
10.
9.
8.
7.
6.
5.
4.
3.
2.
1.
ENGINEER FOR APPROVAL PRIOR TO FABRICATION.
SIGNED AND SEALED CALCULATIONS SHALL BE SUBMITTED TO THE
ENGINEER LICENSED TO PRACTICE IN THE STATE OF NEW JERSEY.
CALCULATIONS SHALL BE PREPARED BY A PROFESSIONAL
TABLE FOR UNIFORM LOAD CONSTANTS AND "L" IS THE SPAN.
R=0.6 Wc/L WHERE "Wc" IS THE UNIFORM LOAD CONSTANT PER AISC
CONNECTIONS FOR STEEL MEMBERS ARE TO BE DESIGNED FOR
WHERE DETAILS OR END REACTIONS ARE NOT GIVEN,
CONNECTIONS UNLESS NOTED OTHERWISE.
A MINIMUM OF TWO (2) BOLTS SHALL BE USED FOR ALL
MANUAL.
ALL ALLOWABLE BOLT LOADS SHALL BE THOSE GIVEN IN THE AISC
TO ASTM F436. NUTS SHALL CONFORM TO ASTM A563.
BOLTS SHALL CONFORM TO ASTM A325. WASHERS SHALL CONFORM
OTHERWISE.
WELDING ELECTRODES SHALL BE E70XX UNLESS NOTED
D1.1, LATEST EDITION.
WELDING SHALL CONFORM TO THE STRUCTURAL WELDING CODE
GRADE 50.
PLATES AND STEEL CHANNELS SHALL CONFORM TO ASTM A572
STRUCTURAL ANGLES SHALL CONFORM TO ASTM A36.
GRADE B WITH A MINIMUM YIELD STRENGTH OF 46 KSI.
HOLLOW STRUCTURAL SECTIONS SHALL CONFORM TO ASTM A500
A992 UNLESS NOTED OTHERWISE.
WIDE FLANGE STRUCTURAL SHAPES SHALL CONFORM TO ASTM
STRUCTURAL STEEL
10.
9.
8.
7.
6.
5.
4.
3.
2.
1.
7.
6.
5.
4.
3.
2.
1.
2.
1.
11.
10.
9.
8.
7.
6.
5.
4.
3.
2.
1.
STRUCTURAL SAFETY - STRUCTURAL STABILITY
CONCRETE
STEEL
FOUNDATIONS
SPECIAL INSPECTION ITEMS:
ALL REQUIRED STRUCTURAL SPECIAL INSPECTIONS.
JERSEY, TO BE APPROVED BY CONTRACTING OFFICER, TO PERFORM
PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF NEW
CONTRACTOR SHALL RETAIN SERVICES OF A LICENSED
SPECIAL INSPECTIONS
BEEN COMPLETED.
BUILT UPON OR OTHERWISE COVERED BEFORE INSPECTIONS HAVE
DESIGNATED INSPECTORS. NO WORK TO BE INSPECTED SHALL BE
CONTRACTOR SHALL COORDINATE HIS WORK WITH THE CO’S
APPROVAL OF THE SHOP DRAWINGS BY THE COR.
ELEMENTS, SHALL COMMENCE WITHOUT PRIOR REVIEW AND
NOT LIMITED TO, FABRICATION OR ERECTION OF NEW STRUCTURAL
APPLICABLE. NO PERFORMANCE OF THE WORK INCLUDING, BUT
BRACING, CONSTRUCTION METHODS, AND SEQUENCING WHERE
ALL PARTS OF THE WORK INCLUDING DESCRIPTION OF TEMPORARY
THE CONTRACTOR SHALL SUBMIT COMPLETE SHOP DRAWINGS FOR
THE MOST NEARLY SIMILAR CONDITION.
SPECIFICALLY SHOWN SHALL BE SIMILAR TO THOSE SHOWN FOR
REQUIRED OTHERWISE BY CONTRACT DOCUMENTS. DETAILS NOT
OF THE STRUCTURAL WORK EXCEPT WHERE SPECIFICALLY
DRAWINGS. TYPICAL DETAILS SHALL BE APPLICABLE TO ALL PARTS
TYPICAL DETAILS AND NOTES ARE SHOWN ON STRUCTURAL
THE CONSTRUCTION ACTIVITY.
BREAKAGE, SETTLEMENT, OR COLLAPSE THAT MAY RESULT FROM
MEASURES NECESSARY TO PROTECT ALL WORK FROM DAMAGE,
SHALL PROVIDE ADEQUATE BRACING, SHORING, AND INSTITUTE
OF CONSTRUCTION THROUGHOUT THE PROJECT DURATION. HE
THE CONTRACTOR IS RESPONSIBLE FOR ALL MEANS AND METHODS
FOR RESOLUTION BEFORE PROCEEDING.
AND CIVIL DRAWINGS. REPORT ALL DISCREPANCIES TO THE C.O.
COORDINATED WITH THOSE INDICATED ON THE ARCHITECTURAL,
DRAWINGS SHALL BE VERIFIED BY THE CONTRACTOR AND SHALL BE
ALL DIMENSIONS AND ELEVATIONS INDICATED ON THE STRUCTURAL
NOTES.
CONFLICT WITH THE INFORMATION SHOWN ON THE GENERAL
SPECIFICATION LANGUAGE SHALL GOVERN IN THE EVENT OF ANY
DISCIPLINES. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION.
MUST BE COORDINATED WITH THE DRAWINGS OF OTHER PROJECT
SHOWN ON THE STRUCTURAL DRAWINGS. STRUCTURAL DRAWINGS
DRIPS, DEPRESSIONS, AND OTHER PROJECT REQUIREMENTS NOT
DIMENSIONS OF CHASES, INSERTS, OPENINGS, SLEEVES, WASHES,
ELECTRICAL DRAWINGS FOR VERIFICATION OF LOCATIONS AND
EXAMINE ARCHITECTURAL, MECHANICAL, PLUMBING, AND
WET WELL AND RETAINING WALL IN THIS CONTRACT.
PLANS AND SPECIFICATIONS SHALL APPLY TO THE PUMP STATION’S
THE FOLLOWING REQUIREMENTS TOGETHER WITH THE PROJECT
GENERAL NOTES
.ALL SLABS ON GRADE SHALL BEAR ON 12" COMPACTED STONE
WATER, FROST, ICE, OR FROZEN SUBGRADE MATERIAL.
NO FOUNDATION CONCRETE SHALL BE PLACED INTO OR AGAINST
STRUCTURE.
ACCUMULATED TO PREVENT FLOTATION OF ANY PART OF THE
MATERIAL. PROVIDE CONTROL UNTIL SUFFICIENT DEAD LOAD HAS
PERFORMED IN DRY CONDITIONS AND ON UNDISTURBED SUBGRADE
WATER DURING CONSTRUCTION SUCH THAT FOUNDATION WORK IS
PROVIDE CONTINUOUS CONTROL OF SURFACE AND SUBSURFACE
THE PREVIOUS STATEMENT.
EITHER BE BACKFILLED EQUALLY OR TEMPORARILY BRACED PER
THE DRAWINGS. WALLS THAT RETAIN SOIL ON BOTH SIDES SHALL
ATTAINED FULL DESIGN STRENGTH, UNLESS NOTED OTHERWISE ON
UNTIL ALL SUPPORTING SLABS ARE IN PLACE AND CONCRETE HAS
WALLS, SHALL BE TEMPORARILY BRACED DURING BACKFILLING
WALLS RETAINING SOIL, EXCEPT FOR CANTILEVER RETAINING
BACKFILL AND COMPACTION OPERATIONS.
ATTAINED SUFFICIENT STRENGTH TO RESIST PRESSURE FROM
SUBGRADE FOUNDATION ELEMENTS UNTIL CONCRETE HAS
DO NOT BACKFILL AGAINST FOUNDATION WALLS, OR OTHER
ALL SUCH CONDITIONS PRIOR TO CONSTRUCTION.
ENGINEER. CONTRACTOR SHALL SUBMIT DETAILED DRAWINGS OF
FOUNDATIONS WITHOUT APPROVAL OF THE STRUCTURAL
UTILITY LINES SHALL NOT BE PLACED THROUGH OR BELOW
FINISH GRADE.
GRADE. BOTTOM OF FOOTINGS SHALL BE PLACED 4 FEET BELOW
DESIGN FROST PENETRATION DEPTH IS 48 INCHES BELOW FINISHED
5000 PSF.
SOIL BEARING CAPACITY FOR WET WELL AND RETAINING WALL IS
AFFECTED BY THE CONSTRUCTION PROCESS.
WORK. LOCATE AND PROTECT ALL UTILITIES WHICH MAY BE
INSTALLATION OF THE FOUNDATION SYSTEM PRIOR TO STARTING
VERIFY ALL EXISTING FIELD CONDITIONS THAT MAY AFFECT THE
DRAWINGS.
CONTRACT SPECIFICATIONS UNLESS NOTED OTHERWISE ON THE
SELECT STRUCTURAL FILL INSTALLED IN ACCORDANCE WITH
ALL SPREAD FOOTINGS SHALL BEAR ON COMPETENT SOIL OR
ENGINEERING GROUP DATED DECEMBER 18, 2014.
PROVIDED IN A TECHNICAL MEMORANDUM PROVIDED BY JACOBS
FOUNDATION DESIGN IS IN ACCORDANCE WITH RECOMMENDATIONS
FOUNDATIONS
DIRECTED BY THE ENGINEER.
WATERSTOPS AT LOCATIONS SHOWN ON THE DRAWINGS OR AS
CONSTRUCTION JOINTS SHALL BE PROVIDED WITH PVC
NOTED ABOVE.
CONDITIONS WHICH CREATE CONGESTION BEYOND RESTRICTIONS
C.O. MAY REQUIRE REPOSITIONING OF CONDUIT BASED ON FIELD
THICKNESS.
C. THEY SHALL BE LOCATED IN THE MIDDLE THIRD OF SLAB OR WALL
OR WIDTHS ON CENTER
B. THEY SHALL NOT BE SPACED CLOSER THAN THREE (3) DIAMETERS
A. THEY SHALL NOT BE LARGER THAN 1" OUTSIDE DIAMETER
PASSING THROUGH) SHALL SATISFY THE FOLLOWING:
WITHIN A SLAB, WALL, OR BEAM (OTHER THAN THOSE MERELY
BY THE STRUCTURAL ENGINEER, CONDUITS OR PIPES EMBEDDED
EXCEPT WHEN DRAWINGS FOR PIPES OR CONDUITS ARE APPROVED
LOCATION OF ALL PENETRATIONS FOR APPROVAL BY THE C.O.
SUBMIT COORDINATION DRAWINGS SHOWING THE DIMENSIONED
PRIOR TO PLACING ANY CONCRETE THE CONTRACTOR SHALL
SHALL BE STAINLESS STEEL.
CONCRETE SHALL BE HOT DIP GALVANIZED AFTER FABRICATION OR
ALL STEEL PLATES, INSERTS, OR OTHER ITEMS TO BE EMBEDDED IN
IS AT NO POINT LESS THAN THAT INDICATED ON THE DRAWINGS.
CONCRETE SLABS SHALL BE PLACED SO THAT THE SLAB THICKNESS
BE CONTINUOUS THROUGH JOINT, UNLESS NOTED OTHERWISE.
BY 1/3 THE DEPTH OR WIDTH OF THE MEMBER. REINFORCING SHALL
WALLS, AND BEAMS. THE MINIMUM KEY SIZE SHALL BE 1-1/2" DEEP
THE DRAWINGS, PROVIDE A CONTINUOUS SHEAR KEY IN SLABS,
SUBJECT TO REVIEW BY THE COR. UNLESS NOTED OTHERWISE ON
THE STRENGTH OF THE BEAM, SLAB, OR WALL AND SHALL BE
ON THE DRAWINGS, THEY SHALL BE LOCATED AS NOT TO IMPAIR
WHERE CONSTRUCTION JOINTS ARE REQUIRED BUT NOT INDICATED
JOINTS AS SHOWN ON THE PLAN.
STRIPS WITH STRIPS DEFINED BY TWO ADJACENT CONSTRUCTION
CONCRETE FOR SLABS-ON-GRADE SHALL BE PLACED IN SINGLE
OF A CONSTRUCTION JOINT DETAILED AS SHOWN IN THE DRAWINGS.
"CJ" ON THE SLAB-ON-GRADE PLAN INDICATES REQUIRED LOCATION
ON CENTER.
CONSTRUCTION JOINTS SHALL BE LOCATED AT NO MORE THAN 40’-0"
LOCATIONS OF ALL CONSTRUCTION JOINTS. WHERE NOT SHOWN,
THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS INDICATING THE
INDICATED ON THE DRAWINGS OR AS APPROVED BY THE ENGINEER.
CONTROL/CONSTRUCTION JOINTS SHALL BE PROVIDED AS
INHIBITING ADMIXTURE.
ALL ABOVE GRADE CONCRETE SHALL CONTAIN A CORROSION
PSI.
COMPRESSIVE STRENGTH OF CONCRETE AT 28 DAYS SHALL BE 4000
ALL CONCRETE SHALL BE NORMAL WEIGHT CONCRETE. MINIMUM
REQUIREMENTS SHALL APPLY.
(ACI 304). IN CASE OF CONFLICT, THE MOST STRINGENT
FOR MEASURING, MIXING, TRANSPORTING AND PLACING CONCRETE"
PLACEMENT SHALL CONFORM TO THE LATEST EDITION OF "GUIDE
STRUCTURAL CONCRETE FOR BUILDINGS" (ACI 301). CONCRETE
CONCRETE STRUCTURES (ACI 350-06) AND "SPECIFICATIONS FOR
CODE REQUIREMENTS FOR ENVIRONMENTAL ENGINEERING
CODE REQUIREMENTS FOR REINFORCED CONCRETE" (ACI 318-11),
CAST-IN-PLACE CONCRETE WORK SHALL CONFORM TO "BUILDING
CONCRETE
FOUNDATION
IN CONTACT WITH
UNFORMED SURFACES
4"
4"
COVER
CLEAR
SURFACE CONDITIONS
STRUCTURES (EM-1110-2-2104)
STRENGTH DESIGN FOR REINFORCED-CONCRETE HYDRAULIC
RETAINING AND FLOOD WALLS (EM-1110-2-2502)
STABILITY ANALYSIS OF CONCRETE STRUCTURES (EM-1110-2-2100)
(EM-1110-2-3104)
STRUCTURAL AND ARCHITECTURAL DESIGN OF PUMPING STATIONS
ENGINEERING" (1 NOVEMBER 2012)
UNIFIED FACILITIES CRITERIA (UFC) 3-220-01, "GEOTECHNICAL
BUILDINGS" (1 JUNE 2013)
UNIFIED FACILITIES CRITERIA (UFC) 3-310-04, "SEISMIC DESIGN OF
ENGINEERING" (15 MAY 2014)
UNIFIED FACILITIES CRITERIA (UFC) 3-301-01, "STRUCTURAL
REQUIREMENTS" (1 NOVEMBER 2014)
UNIFIED FACILITIES CRITERIA (UFC) 1-200-01, "GENERAL BUILDING
CONSTRUCTION MANUAL (14TH EDITION)
AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC) STEEL
350-06)
ENVIRONMENTAL ENGINEERING CONCRETE STRUCTURES (ACI
AMERICAN CONCRETE INSTITUTE (ACI) CODE REQUIREMENTS FOR
REQUIREMENTS FOR REINFORCED CONCRETE (ACI 318-11)
AMERICAN CONCRETE INSTITUTE (ACI) BUILDING CODE
LOADS FOR BUILDINGS AND OTHER STRUCTURES (ASCE 7-10)
AMERICAN SOCIETY OF CIVIL ENGINEERS (ASCE) MINIMUM DESIGN
BUILDING CODE - NEW JERSEY EDITION (IBC-NJ)
CHECKED FOR COMPLIANCE WITH THE 2009 INTERNATIONAL
2012 INTERNATIONAL BUILDING CODE (IBC) (WORK HAS BEEN
FOLLOWING CODES, SPECIFICATIONS, AND STANDARDS:
THE DESIGN SHOWN ON THESE DRAWINGS IS BASED ON THE
REFERENCED CODES AND STANDARDS
13.
12.
11.
10.
9.
8.
7.
6.
5.
4.
3.
2.
1.
3"
SCREEDED SURFACES
ALL OTHER FORMED OR
THAN 24" IN THICKNESS
SURFACES EQ. OR GREATER
FORMED OR SCREEDED
SURFACE CONDITIONS AND ELEMENT THICKNESS
SEE TABLE BELOW FOR THE CONCRETE CLEAR COVER BASED ON
REINFORCEMENT SHALL NOT BE TACK WELDED.
SECURELY.
PANELS, BUT NOT LESS THAN 12 INCHES, AND SHALL BE TIED
WELDED WIRE FABRIC SHALL BE LAPPED TWO (2) FULL MESH
OF MAIN REINFORCING, UNLESS NOTED OTHERWISE.
WHERE REQUIRED, DOWELS SHALL MATCH BAR SIZE AND NUMBER
DRAWINGS.
IN COMPLIANCE WITH ACI 318, UNLESS NOTED OTHERWISE ON THE
REINFORCING STEEL SPLICES AND ANCHORAGE LENGTHS SHALL BE
OTHERWISE.
SHALL BE CLASS B TENSION LAP SPLICES, UNLESS NOTED
NECESSARY SPLICES OR HOOKED AT DISCONTINUOUS ENDS. LAPS
EXTENDED CONTINUOUSLY AROUND CORNERS AND LAPPED AT
WHERE CONTINUOUS REINFORCEMENT IS CALLED FOR, IT SHALL BE
POSITION SHOWN ON THE DRAWINGS BEFORE PLACING CONCRETE.
ALL REINFORCEMENT SHALL BE SECURELY TIED IN PLACE AT THE
ACCESSORIES TO HOLD REINFORCEMENT SECURELY IN POSITION.
PROVIDE AND SCHEDULE ON SHOP DRAWINGS THE NECESSARY
WELDED WIRE FABRIC (WWF) SHALL CONFORM TO ASTM A185.
GALVANIZED.
ALL REINFORCING FOR WET WELL STRUCTURE SHALL BE
REINFORCING STEEL SHALL CONFORM TO ASTM A615 (GRADE 60).
315).
OF "DETAILS AND DETAILING OF CONCRETE REINFORCEMENT" (ACI
FOR REINFORCED CONCRETE" (ACI 318) AND THE LATEST EDITION
ERECTION SHALL CONFORM TO "BUILDING CODE REQUIREMENTS
REINFORCEMENT WORK OF DETAILING, FABRICATION, AND
REINFORCEMENT
fiof Engineers
US Army Corps of Engineers
US Army Corps
IS
S
U E D
A T
E
N E
W Y
O R
K
N E
W Y
O R
K
N E
W Y
O R
K D
IS
T R
IC
T
U S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
A M
M A
N N W
H
IT
N E
Y J
O
IN
T V
E N
T U
R E
SHEET OF 116
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
D A
T E
A P
P R
J A
C O
B S
A N
S I
D
A P
R
IL
IDENTIFICATION
SHEET
B O
R O
O F M
ID
D
L E
S E
X N
J
S E
G M
E N
T B -3
G R
E E
N B
R O
O K S
U B -B
A S
IN
O
F T
H E R
A R
IT
A N R
IV
E R
G R
E E
N B
R O
O K F
L O
O D R
IS
K M
A N
A G
E M
E N
T P
R O J E
C T
W
D S -1
-B -0
SF-801
S T
R U
C T
U R
A L
P U
M P S
T A
T
IO
N G
L -5
G E
N E
R A
L N
O T
E S I
B L
B L
J B
/0
/2
/0
/1
A
D D
E N
D U
M
17’-6"
5’-0"
SLAB, TYP.
EDGE OF
SF-807
A
EL. 46.00’
EL. 46.25’
EL. 43.50’
SF-807
A
SF-806
B
SF-806
A
SF-806
B
SF-807
A
N
S L
O P
E
SF-806
A
T Y
P
/4
T Y
P
SF-807
A
SF-808
A
SF-808
A
SF-807
B
SF-807
B
SF-808
B
SF-808
D
SF-808
C
4’-0"
SF-808
D
SF-808
B
7’-8 3/4 "3’-0"
UP UP
= 5’-6" 6T @ 11"
4’-0" LANDING
14T @ 11" = 12’-10"
56’-6"
/4
STEEL ACCESS STAIRS
3’-6"
3’-0"
CL
CL
SF-804
A
SF-804
A
CONCRETE SLAB
DIAMETER HOLE IN
9’-4"32’- 1/8 "
SEE NOTE 1
(APPROX. WT. 88 LBS.)
SEE NOTE 1
GRATING SECTION.
3’x4’ TYP. HINGED BAR
SF-814
SEE DWG.
LOCK DETAIL,
SEE GRATING
SF-814
SEE DWG.
DETAIL,
HINGE
SEE GRATING
SEE NOTE 2 & 3
SEE NOTE 2 & 3
SEE NOTE 2 & 3
SEE NOTE 1
4. CONCRETE OPENING COVERED BY HYDRAULIC HATCH
3. FIXED LADDER, SEE SF-811 FOR DETAILS
LADDERUP SAFETY POST BY BILCO OR APPROVED EQAUL
2. CONCRETE OPENING COVERED BY HYDRAULIC HATCH W/
GALVANIZED. TYPICAL ALL GRATING.
" BEARING BARS, 16
" x 2
1. STEEL GRATING SHALL BE 19-W-4 WITH 1
NOTES:
SEE NOTE 4
#4@12" EW, EF
REINFORCE w/
DIVIDER WALL.
CONCRETE
3’-6"
80’-0"
3’-0"
12’-6"
15’-7 7/8 "
RETAINING WALL
JOINT FILLER
1" COMPRESSIBLE
10’-0" 7
REINFORCEMENT
SEE 2/SF-807 FOR BEAM
BARS T & B
2 ADD’TL #8
FOR DETAILS
SEE MECH. DWGS.
STILLING WELL
FOR DETAILS
SEE MECH. DWGS.
STILLING WELL
SEE 1/SF-804
COVER PLATE
PUMP OPENING
(4 PLACES)
SLAB, TYP.
3’-8" DIA. OPENING IN
PIPE SLEEVE
6" PVC SCH. 40
SLAB BENEATH
3’-8" HOLE IN
1 1/2" DIA. HOLE
BY 2 HEX NUTS
PLATE CAPTURED
3" SQ. x 1/4" THICK STEEL TYP.
TYPE 316 STAINLESS
1" DIA. ANCHOR BOLTS
GALVANIZED STEEL
1" THICK STEEL PLATE,
2’-8" 2’-5 1/2 "
/2
2’-9"
3’-8" fiof Engineers
US Army Corps of Engineers
US Army Corps
IS
S
U E D
A T
E
N E
W Y
O R
K
N E
W Y
O R
K
N E
W Y
O R
K D
IS
T R
IC
T
U S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
A M
M A
N N W
H
IT
N E
Y J
O
IN
T V
E N
T U
R E
SHEET OF 116
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
D A
T E
A P
P R
J A
C O
B S
A N
S I
D
A P
R
IL
IDENTIFICATION
SHEET
B O
R O
O F M
ID
D
L E
S E
X N
J
S E
G M
E N
T B -3
G R
E E
N B
R O
O K S
U B -B
A S
IN
O
F T
H E R
A R
IT
A N R
IV
E R
G R
E E
N B
R O
O K F
L O
O D R
IS
K M
A N
A G
E M
E N
T P
R O J E
C T
W
D S -1
-B -0
SF-804
T
R U
C T
U R
A L
W E
T W
E L L M
ID
L
E V
E L P
L A
N
P U
M P S
T A
T
IO
N G
L -5
B L
" = 1’-0"16
SCALE
HIGH LEVEL PLAN - EL. 46.25’MID LEVEL PLAN - EL. 43.50’
" = 1’-0"16
SCALE
0 4’ 8’ 12’
" = 1’-0"16
SCALE
0 1’ 2’
SCALE 1" = 1’-0"
A
SECTION
SCALE 1/2" = 1’-0"1
DETAIL OF STEEL PLATE
SCALE 1/2" = 1’-0"
J B
B L
-0
-1
V A
R
IE
/0
/1
A
D D
E N
D U
M
SF-806
U
M P S
T A
T
IO
N G
L -5
W E
T W
E L L S
E C
T
IO
N I
S T
R U
C T
U R
J B
B L
4’ 8’0 2’
A
SECTION
" = 1’-0"4
SCALE
B
SECTION
" = 1’-0"4
SCALE
SF-805
SF-804
SF-803
SF-804 & SF-805
SF-803 " = 1’-0"4
SCALE
B L
-0
-2
/4
/0
/1
A
D D
E N
D U
M fiof Engineers
US Army Corps of Engineers
US Army Corps
IS
S
U E D
A T
E
N E
W Y
O R
K
N E
W Y
O R
K
N E
W Y
O R
K D
IS
T R
IC
T
U S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
A M
M A
N N W
H
IT
N E
Y J
O
IN
T V
E N
T U
R E
SHEET OF 116
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
D A
T E
A P
P R
J A
C O
B S
A N
S I
D
A P
R
IL
IDENTIFICATION
SHEET
B O
R O
O F M
ID
D
L E
S E
X N
J
S E
G M
E N
T B -3
G R
E E
N B
R O
O K S
U B -B
A S
IN
O
F T
H E R
A R
IT
A N R
IV
E R
G R
E E
N B
R O
O K F
L O
O D R
IS
K M
A N
A G
E M
E N
T P
R O J E
C T
W
D S -1
-B -0
STEEL STAIRS
ACCESS HATCH
BAR SCREEN
GRATING
EL. 25.15’
T/SLAB
EL. 31.00’
B/OPNG
EL. 31.75’
TYP.
SLAB WITH WATERSTOP,
6" HIGH CURB CAST WITH
TRASH RACK
EL. 32.15’
8’-0"
4’-0"3’-0"
HINGED GRATING
GRATING
STEEL GUARDRAIL
EL. 31.85’
TRASH RACK
EL. 31.55’
4’-0"
T/SLAB EL.
B/FOOT EL.
T/SLAB EL.
T/WALL EL.
1’-6"
T/WALL EL.
T/SLAB EL.
M
IN
M
IN
1’-6"
18’-6"
T/SLAB EL.
B/FOOT EL.
T/SLAB EL.
B/SUMP PIT EL. 21.75’
T/GRADE
SEE CIVIL DWGS.
T/GRADE
SEE CIVIL DWGS.
43.50’
32.00’
27.00’
NOTE:
OUTER LAYERS OF REINFORCEMENT TO
BE EAST-WEST BARS IN SLABS.
LP EL. 24.75’
56.50’
31.50’
52.33’
43.50’
32.00’
27.00’
SEE SECTION A FOR REINFORCEMENT NOT SHOWN.
CONCRETE SLAB REINFORCING SCHEDULE
SF-807
#8 @ 12"
#8 @ 6"
#9 @ 6"
#5 @ 6"
#9 @ 6"
#5 @ 6"
#5 @ 6"#5 @ 6"
#9 @ 12"#9 @ 12"
SLABS (U.N.O.)
#9 @ 6" #9 @ 6"
#5 @ 6"
#5 @ 6"
#5 @ 6" #5 @ 6"
#9 @ 6" #9 @ 6"
T/WALL EL. 56.50’
T/SLAB EL. VARIES
HANDRAIL
36" HIGH
TO STAIRWAY
ACCESS GATE
C6x13 TYP.C6x13 TYP.
MC8x21.4
2/SF-817.
TYPICAL DETAIL
AT OPENINGS, SEE
REINFORCEMENT
FOR ADDITIONAL
T/SLAB EL. 25.50’
26’-6" TO SLOPE CHANGE
24’-3"
19’-9 3/8 "
B/SUMP PIT SLAB EL. 19.25’
3’-3"
9’-3"
2’-6"
1’-6"54’-6"
/4
SEE MECH. DWGS.
STILLING WELL
OPENING FOR
EL. 52.10’
SEE 1/SF-808
FOR DETAIL & REINF.
4’-0"
1’-3"
DECORATIVE ALUMINUM FENCE
GUARDRAIL TYP.
1’-10 2"
SLAB WITH WATERSTOP, TYP.
6" HIGH CURB CAST WITH
3" FILLET AT CORNERS OF OPENINGS
SEE TYPICAL DETAIL 2/SF-817.
FOR ADDT’L REINF. AT OPENINGS,
SLAB EDGE BEYOND
GRATING TYP.
STEEL
SEE NOTE 2
SEE NOTES 1 & 2
8’-0" x 4’-0" OPENING.
SEE NOTES 1, 2 & 3
OPENING
4’ HIGH X 6’ WIDE
SEE NOTES 1 & 3
OPENING
WATERSTOP
PIPE SLEEVE W/
3’-6" DIA. S.S.
NOTE 1 & 2
OPENING SEE
8’ WIDE X 4’ HIGH
NOTES:
1. OPENING FOR FUTURE SLUICE GATE.
2. SEE MECHANICAL DRAWING D-100 FOR LOCATIONS OF
GROUT POCKETS AND STRUCTURAL DRAWING DETAIL 7/SF-817.
3. SEE MECHANICAL DRAWINGS D-100 AND D-304 FOR
LOCATIONS AND DETAILS OF CLOSURE PLATES FOR OPENING
OF FUTURE SLUICE GATES.
2’-0" THICK
2’-6" THICK
#8@12" EAST-WEST TOP
#8@6" EAST-WEST BOTTOM
#5@6" NORTH-SOUTH T&B
#9 @ 6" #9 @ 6"
#9 @ 6"#9 @ 6"
#5 @ 6" #5 @ 6"
SF-807
#8@6" EAST-WEST TOP
#8@12" EAST-WEST BOTTOM
#5@6" NORTH-SOUTH T&B
1’-6" THICK
#8@12" EAST-WEST TOP
#8@6" EAST-WEST BOTTOM
#5@6" NORTH-SOUTH T&B
SF-807
U
M P S
T A
T
IO
N G
L -5
W E
T W
E L L S
E C
T
IO
N S I I
S T
R U
C T
U R
A L
0 1’ 2’
4’ 8’0 2’
SCALE 1" = 1’-0"
" = 1’-0"4
SCALE
BEAM REINFORCEMENT DETAIL
SCALE 1" = 1’-0"
A
SECTION
" = 1’-0"4
SCALE
B
SECTION
" = 1’-0"4
SCALE
SF-804 & SF-805
SF-803
SF-804 & SF-805
SF-803
-0
-2
V A
R
B
B L
J B
BEAM REINFORCEMENT DETAIL
SCALE 1" = 1’-0"
SF-806
SEE SECTION B FOR REINFORCEMENT NOT SHOWN
1 1
1 1
A
D D
E N
D U
M
/0
/1
SF-804 & SF-806
fiof Engineers
US Army Corps of Engineers
US Army Corps
IS
S
U E D
A T
E
N E
W Y
O R
K
N E
W Y
O R
K
N E
W Y
O R
K D
IS
T R
IC
T
U S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
A M
M A
N N W
H
IT
N E
Y J
O
IN
T V
E N
T U
R E
SHEET OF 116
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
D A
T E
A P
P R
J A
C O
B S
A N
S I
D
A P
R
IL
IDENTIFICATION
SHEET
B O
R O
O F M
ID
D
L E
S E
X N
J
S E
G M
E N
T B -3
G R
E E
N B
R O
O K S
U B -B
A S
IN
O
F T
H E R
A R
IT
A N R
IV
E R
G R
E E
N B
R O
O K F
L O
O D R
IS
K M
A N
A G
E M
E N
T P
R O J E
C T
W
D S -1
-B -0
#3 TIES @ 6" O.C.
3’-0"
3’-7 3/4 "
/8
TRASH RACK
4 - #8 BARS
/8
#8 FACE BAR, TYP.
5 - #8 BARS
4 - #8 BARS
AT ELEV. 43.50’
TOP OF CONCRETE SLAB
REINF. DETAIL
SEE A/SF-806 FOR
REINF. DETAIL
SEE A/SF-806 FOR
RACK CORBEL)
(FOR TRASH
3 - #8 BARS
#4 TIE @ 8" O.C.
#4 TIE @ 8" O.C.
DISTANCE)
SPACING OF 3" CLEAR
(IN 2 ROWS W/ VERTICAL
12 - #10 BARS
WATERSTOP, TYP.
WITH SLAB WITH
6" HIGH CURB CAST
T/O WALL 52.33’
1’-0" 1’-0"1’-6"
30’-6"
2’-0"
2’-0"
10’-0"
1’-0"
#8 @ 6"
#8 @ 12"
#5 @ 6"
#5 @ 6"
#9 @ 6"#9 @ 6"
#8 @ 12"
#8 @ 6"
#5 @ 6"
#9 @ 12"
#5 @ 6" #5 @ 6"
#5 @ 6" #5 @ 6"
52.33’
43.50’
DECORATIVE FENCE
6’" HIGH ALUMINUM
#9 @ 6"#9 @ 6"#9 @ 12"
#5 @ 6"
EL. 56.50’
T/WALL
EL. 31.50’
T/SLAB
EL. 46.00’
T/SLAB
GRATING
SEE CIVIL DWGS.
T/GRADE
SEE CIVIL DWGS.
T/GRADE
SEE CIVIL DWGS.
T/GRADE
SEE CIVIL DWGS.
T/GRADE
T/SLAB EL.
T/SLAB EL.
T/WALL EL.
T/WALL EL.
T/SLAB EL.
56.50’
46.25’
25.50’
T/O SLAB VARIES
T/O SLAB VARIES
GRATING
(TYP.)
SLEEVE W/ 2" WATERSTOP
Ø 3’-6" OPENING WALL
SEE TYPICAL DETAIL 2/SF-817
REINFORCEMENT AT OPENINGS,
FOR ADDITIONAL
8’-0"8’-0"8’-0"5’-3"
2’-9"
2’-7"
SLEEVE
6" PIPE
EL. 52.10’
SLEEVE
12" PIPE
EL. 54.93’
EL. 54.00’
DETAILS.
GROUT POCKETS AND STRUCTURAL DRAWING SF-817 FOR
2. SEE MECHANICAL DRAWING D-100 FOR LOCATIONS OF
1. OPENING FOR FUTURE SLUICE GATE.
NOTES:
SEE NOTES 1 & 2
OPENING,
#5 @ 6"
#8 @ 6"
#8 @ 12"
#6 @ 6"
#6 @ 6"
#8 @ 12"
#8 @ 6"
#9 @ 6" #9 @ 6"
#5 @ 6"#5 @ 6"
#5 @ 6"2
SF-808
P U
M P S
T A
T
IO
N G
L -5
W E
T W
E L L S
E C
T
IO
N S I
II
S T
R U
C T
U R
0 1’ 2’
4’ 8’0 2’
BEAM DETAIL
SCALE 1" = 1’-0"
D
WALL SECTION
" = 1’-0"4
SCALE
C
WALL SECTION
" = 1’-0"4
SCALE
A
EAST / WEST SECTION
" = 1’-0"4
SCALE
B
EAST / WEST SECTION
" = 1’-0"4
SCALE
SCALE 1" = 1’-0"
" = 1’-0"4
SCALE
SF-803 SF-804 SF-805
SF-805
SF-804
SF-803
SF-804
SF-803
SF-804
SF-803
SF-806
J B
B L
B L
-0
-2
V A
R
5. FIXED LADDER, SEE SF-811 FOR DETAILS.
APPROVED EQUAL.
HATCH W/ LADDERUP SAFETY POST BY BILCO OR
4. CONCRETE OPENING COVERED BY HYDRAULIC
OPENING OF FUTURE SLUICE GATES.
LOCATIONS AND DETAILS OF CLOSURE PLATES FOR
3. SEE MECHANICAL DRAWINGS D-100 AND D-304 FOR
DETAIL 7/SF-817.
OF GROUT POCKETS AND STRUCTURAL DRAWING
2. SEE MECHANICAL DRAWING D-100 FOR LOCATIONS
1. OPENING FOR FUTURE SLUICE.
NOTES:
A
D D
E N
D U
M
/0
/1 fiof Engineers
US Army Corps of Engineers
US Army Corps
IS
S
U E D
A T
E
N E
W Y
O R
K
N E
W Y
O R
K
N E
W Y
O R
K D
IS
T R
IC
T
U S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
A M
M A
N N W
H
IT
N E
Y J
O
IN
T V
E N
T U
R E
SHEET OF 116
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
D A
T E
A P
P R
J A
C O
B S
A N
S I
D
A P
R
IL
IDENTIFICATION
SHEET
B O
R O
O F M
ID
D
L E
S E
X N
J
S E
G M
E N
T B -3
G R
E E
N B
R O
O K S
U B -B
A S
IN
O
F T
H E R
A R
IT
A N R
IV
E R
G R
E E
N B
R O
O K F
L O
O D R
IS
K M
A N
A G
E M
E N
T P
R O J E
C T
W
D S -1
-B -0
4’-0"8’-0"
3’-3 3/4 "
6’-0"
1’-7 1/2 "
6’-0"
1’-7 1/2 "
6’-0"
1’-7 1/2 "
6’-0"3’-9 3/4 "
SEE CIVIL DWGS.
T/GRADE
42" TALL STEEL RAILING TYP.
SF807 FOR REINFORCEMENT.
SEE SECTION B ON DRAWING
T/O SLAB EL. VARIES
B/O SLAB EL. 29.00’
T/O WALL EL. 52.33’
T/O SLAB EL. 43.50’
B/O SLAB EL. 42.00’
2/SF-817.
AT OPENINGS, SEE TYPICAL DETAIL
FOR ADDITIONAL REINFORCEMENT
(TYP. 4 PLACES)
SEE NOTES 1, 2 & 3
4’x6’ OPENING, SEE NOTES 1 & 2
4’x8’ OPENING, SEE NOTES 4 & 5
1’-0"1’-6"
6’-6"
1’-6"
6’-6"
1’-6"
6’-6"
1’-6"
9’-6"
GRATING
36’-0"
SEE CIVIL DWGS.
T/GRADE
SEE CIVIL DWGS.
T/GRADE
SF807 FOR REINFORCEMENT.
SEE SECTION B ON DRAWING
SF-808
T/O WALL 56.50’
T/O SLAB 43.50’
B/O SLAB 42.00’
T/O SLAB EL. 25.5’
B/O SLAB EL. 23.00’
T/O SLAB EL. 31.50’
B/O SLAB EL. 29.00’
STEEL STAIRS WITH HANDRAIL
LANDING
GUARDRAIL
SECURITY GATE FOR 42" TALL
REINFORCEMENT
SEE A/SF804 FOR
T/O SLAB EL.
B/O SLAB EL.
B/O SLAB EL.
B/O SLAB EL.
T/O SLAB EL.
T/O SLAB EL.
6" CURB
GRATING
30.92’ +/-
28.42’ +/-
43.50’
42.00’
31.79’ +/-
29.00’
T/O SLAB EL.
B/O SLAB EL.
B/O SLAB EL.
T/O SLAB EL.
T/O SLAB EL.
B/O SLAB EL.
43.50’
42.00’
31.75’
29.00’
O.C. OR APPROVED EQUAL
EXPANSION ANCHORS 12"
1/2"=DIA. KWIK BOLT III
L6x4 LLV FASTENED W/
DEEP GRATING
29.17’ +/-
26.67’ +/-
DRAWING FOR REINFORCEMENT.
SEE SECTION C ON THIS
SEE NOTES 1 & 3
OPENING,
GRATING
4 - #6 BARS
5- #8 BARS
#4 TIES @ 10" O.C.
1’-6"
File details come from the government source that posted it. Updated .