Plans_-_Amendment__5.pdf

PDF 5 MB Posted

Attached to
Thule Air Base, Greenland New Building for Vehicle and Equipment Storage
Solicitation number
W912DS-14-B-0007
Issued by

About this file

W912DS-14-B-0007-Plans

View the file

Other files

File Type Posted
FY14_Thule_Consolidation_2_-_Bid_Abstract_-_30_Apr_14_(2).pdf PDF
W912DS-14-B-0007-Amendment_0012_.pdf PDF
W912DS-14-B-0007-Amendment_0011.pdf PDF
Plans_-_Amendment__10.pdf PDF
W912DS-14-B-0007_AMENDMENT_0010.pdf PDF
Plans_-_Amendment_9.pdf PDF
W912DS-14-B-0007_AMENDMENT_0009.pdf PDF
Plans_-_Amendment_8.pdf PDF
W912DS-14-B-0007_Amendment_0008.pdf PDF
W912DS-14-B-0007-0007.pdf PDF
W912DS-14-B-0007-AMENDMENT_0006.pdf PDF
W912DS-14-B-0007_AMENDMENT_0005.pdf PDF
W912DS-14-B-0007_Amendment_0004.pdf PDF
W912DS-14-B-0007_AMENDMENT_0003.pdf PDF
Bid_Schedule_-_Thule_Consolidation_2_-_Amendment__3.pdf PDF
Appendix_T_-_FY14__FY15_Sealift_Rates.pdf PDF
W912DS-14-B-0007-AMENDMENT_0002.pdf PDF
W912DS-14-B-0007-AMENDMENT_0002_Plans.pdf PDF
W912DS-14-B-0007-AMENDMENT_0002_REVISED_BID_SCHEDULE.pdf PDF
W912DS-14-B-0014-AMENDMENT_0001.pdf PDF
Package_1_-_100_Thule_Consolidation_2_-_Plans.pdf PDF
Appendix_U_-_DBA_Waiver.pdf PDF
Appendix_I_-_Slug_Mgmt_Plan.pdf PDF
Appendix_V_-_Project_Site_Survey.dwg DWG drawing
Appendix_J_-_Installation_HAZMAT_Management_Plan.pdf PDF
Appendix_L_-_Affirmative_Proc_Plan.pdf PDF
Package_2_-_100_Thule_Consolidation_2_-_Specifications.pdf PDF
Package_3_-_100_Thule_Consolidation_2_-_SID-CID.pdf PDF
Appendix_D_-_HWM_Plan.pdf PDF
Appendix_M_-_PCB_Replacement_Plan.pdf PDF
Appendix_E_-_Spill_Prevention-Response_Plan.pdf PDF
Appendix_F_-_PPM_Plan.pdf PDF
Appendix_A_-_Active_Landfills.pdf PDF
Appendix_B_-_NFS_Material_Borrow_Site.pdf PDF
Appendix_N_-_Asbestos_Management_Plan.pdf PDF
Appendix_S_-_Pacer_Goose_Shipping_Instructions.pdf PDF
Appendix_P_-_Demo_As-Built_and_Asbestos_Surveys.pdf PDF
Appendix_K_-_FGS-GL_(Environmental_Protection).pdf PDF
Appendix_O_-_Lead_Paint_Management_Plan.pdf PDF
W912DS-14-B-0007_SOLICITATION.pdf PDF
Appendix_C_-_Conservation_Mgmt_Plan.pdf PDF
Appendix_H_-_Storm_Water_Mgmt_Plan.pdf PDF
Appendix_G_-_Solid_Waste_Mgmt_Plan.pdf PDF
Appendix_R_-_Geotechnical_Investigation.pdf PDF
Appendix_Q_-_Shipping_Rates_Gov_Furnished_Transport.pdf PDF
Appendix_T_-_FY14_Sealift_Rates.pdf PDF
Show all 46

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

US Army Corps of Engineers New York District

SY

M

BO

L

R

EV

IS

IO

N D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

U

.S .A

R M

Y C

O R

PS

O

FE

N

G

IN

EE

R

S N

EW

Y

O R

K D

IS

TR

IC

T ht tp w w w

.n an

.u sa ce .a rm y.

m il

SHEET

REFERENCE

NUMBER:

DATE:

FILE PATH:

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

F

ED

ER

AL

P

LA

ZA

R O

O M

N

EW

Y

O R

K, N

Y

8-

A N

SI

D

DA

TE

SO

LI

C

IT

A

TI

O N

N O

C O

N

TR

A C

T N

O

FI

LE

N U

M B

ER

FI

LE

N A

M E:

PL

O

T D

A

TE

C K

D B

Y:

D

W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B

M

IT

TE

D

B Y:

PL

O

T

SC

A

LE

SI

ZE

PR

O

JE

CT

S

TA

TU

S:

TH

U

LE

A

IR

B

AS

E

G R

EE

N

LA

N

D

TH

U

LE

C O

N

SO

LI

D

AT

ED

W

2D S-

-B

-0

C:\Users\E3ENDCPP\Documents\ARCH_C2_E3ENDCPP.rvt

3/26/2014 9:31:27 AM

AM

EN

D

M

EN

T

3/

/1

G-002

D R

AW

IN

G L

IS

T

M

AR

C

H

N M

W

N M

W R

T

AM

EN

D M

EN

T

DRAWING LIST

SHEET NO.

SHEET

NUMBER SHEET TITLE

231 EP-101C-M FIRST FLOOR POWER - PART PLAN - C - MECH LOADS

(OPTION NO.1)

232 EP-101D FIRST FLOOR MEZZANINE POWER - PART PLAN

233 EP-101E POWER 7 LIGHTING - PIT AREAS

234 EP-102A SECOND FLOOR POWER - PART PLAN - CATWALK

235 EP-102B POWER PLAN - SECOND FLOOR - PART PLAN - B - CATWALK

AREAS

236 EP-102C SECOND FLOOR POWER PL - PART 2 (SERVICE ENTRANCE)

237 EP-103 HVAC POWER - BLDG 1401 (K-PLANT)

238 EP-401 ELEVATION 1

239 EP-402 ELEVATIONS 2

240 EP-403 ELEVATIONS 3

241 EP-404 ENLARGED FLOORPLANS ELECTRICAL/TELECOM SPACES

242 EP-410 HEAT TRACE DETAILS

243 EP-501 ELECTRICAL DETAILS 1

244 EP-601 ELECTRICAL RISER DIAGRAMS

245 EP-602 FEEDER SCHEDULE

246 EP-603A MOTOR AND EQUIPMENT LOAD BRANCH CIRCUIT

SCHEDULE - 1

247 EP-603B MOTOR AND EQUIPMENT LOAD BRANCH CIRCUIT

SCHEDULE - 2

248 EP-603C MOTOR AND EQUIPMENT LOAD BRANCH CIRCUIT

SCHEDULE - 3

249 EP-603D MOTOR AND EQUIPMENT LOAD BRANCH CIRCUIT

SCHEDULE - 4

250 EP-603E MOTOR AND EQUIPMENT LOAD BRANCH CIRCUIT

SCHEDULE - 5

251 EP-603F MOTOR AND EQUIPMENT LOAD BRANCH CIRCUIT

SCHEDULE - 6

252 EP-603G MOTOR AND EQUIPMENT LOAD BRANCH CIRCUIT

SCHEDULE - 7

253 EP-603H MOTOR AND EQUIPMENT LOAD BRANCH CIRCUIT

SCHEDULE - 8

254 EP-604A SHOP EQUIPMENT SCHEDULE - 1

255 EP-604B SHOP EQUIPMENT SCHEDULE - 2

256 EP-605A ELECTRICAL EQUIPMENT SCHEDULE - 1

257 EP-611 PANEL SCHEDULES - 1

258 EP-612 PANEL SCHEDULES - 2

259 EP-613 PANEL SCHEDULES - 3

260 EP-614 PANEL SCHEDULES - 4

261 EP-615 PANEL SCHEDULES - 5

262 EP-616 PANEL SCHEDULES - 6

263 EP-617 PANEL SCHEDULES - 7

264 ET-101A FIRST FLOOR TELECOM - PART PLAN A

265 ET-101B FIRST FLOOR TELECOM- PART PLAN B

266 ET-101C FIRST FLOOR TELECOM - PART PLAN C

267 ET-101D FIRST FLOOR MEZZANINE TELECOM - PART PLAN

268 ET-102A SECOND FLOOR TELECOM - PART PLAN A

269 ET-501 TELECOMMUNICATION DETAILS 1

270 ET-502 TELECOMMUNICATION DETAILS 2

271 ET-503 TELECOMMUNICATION - DETAILS 3

272 ET-504 TELECOMMUNICATION - DETAILS 4

273 ET-601 TELECOMMUNICATION RISER DIAGRAM

274 ET-603 CARD ACCESS RISER DIAGRAM

275 ET-604 PAGING SYSTEM RISER DIAGRAM

276 P-001 PLUMBING LEGEND

277 P-101 PLUMBING FIRST FLOOR PLAN

278 P-102 PLUMBING SECOND FLOOR PLAN

279 P-301 PLUMBING ENLARGED PLANS

280 P-302 PLUMBING ENLARGED PLANS

281 P-401 PLUMBING DOMESTIC WATER RISER DIAGRAM

282 P-402 PLUMBING SANITARY & VENT RISER DIAGRAM

283 P-403 COMPRESSED AIR RISER DIAGRAM

284 P-404 PLUMBING BUILDING SECTIONS

285 P-501 PLUMBING DETAILS

286 P-502 PLUMBING DETAILS

287 P-601 PLUMBING SCHEDULES

288 FA-001 FIRE ALARM GENERAL NOTES

289 FA-101 FIRE ALARM FIRST FLOOR PLAN

290 FA-102 FIRE ALARM SECOND FLOOR PLAN

291 FA-501 FIRE ALARM DETAILS

292 FX-001 FIRE SUPPRESSION GENERAL NOTES

293 FX-101 FIRE SUPPRESSION FIRST FLOOR PLAN

294 FX-102 FIRE SUPPRESSION SECOND FLOOR PLAN

295 FX-501 FIRE SUPPRESSION DETAILS

DRAWING LIST

SHEET NO.

SHEET

NUMBER SHEET TITLE

161 M-103B MECHANICAL SECOND FLOOR PLAN - PART B - DUCTWORK

162 M-103C MECHANICAL SECOND FLOOR PLAN - PART C - DUCTWORK

163 M-104 MECHANICAL SECOND FLOOR PLAN - PIPING

164 M-104A MECHANICAL SECOND FLOOR PLAN - PART A - PIPING

165 M-104B MECHANICAL SECOND FLOOR PLAN - PART B - PIPING

166 M-104C MECHANICAL SECOND FLOOR PLAN - PART C - PIPING

167 M-111A INDUSTRIAL EQUIPMENT FIRST FLOOR PLAN - PART A HVAC

168 M-111B INDUSTRIAL EQUIPMENT FIRST FLOOR PLAN - PART B HVAC

169 M-112A INDUSTRIAL EQUIPMENT SECOND FLOOR PLAN - PART A

HVAC

170 M-112B INDUSTRIAL EQUIPMENT SECOND FLOOR PLAN - PART B

HVAC

171 M-201 HVAC BUILDING 1401

172 M-202 SECOND FLOOR ENLARGED MECAHNICAL ROOM PLAN

173 M-203 AHU-5 SECTION

174 M-211 PAINT BOOTH SECTION

175 M-501 HVAC DETAILS

176 M-502 HVAC DETAILS

177 M-503 HVAC DETAILS

178 M-601 HVAC SCHEDULES

179 M-602 HVAC SCHEDULES

180 M-603 HVAC SCHEDULES

181 M-611 INDUSTRIAL EQUIPMENT HVAC SCHEDULES

182 M-701 HEAT EXCHANGER SINGLE LINE DIAGRAM

183 M-801 HVAC CONTROL DIAGRAM

184 M-802 HVAC CONTROL DIAGRAM

185 M-803 HVAC CONTROL DIAGRAM

186 M-804 HVAC CONTROL DIAGRAM

187 M-805 HVAC CONTROL DIAGRAM

188 M-806 HVAC CONTROL POINTS SCHEDULE

189 M-807 HVAC CONTROL POINTS SCHEDULE

190 E-001 ELECTRICAL SYMBOLS AND LEGEND

191 E-002 ELECTRICAL NOTES - 1

192 E-003 ELECTRICAL NOTES - 2

193 ES-001 SITE ELECTRICAL NOTES

194 ES-101 SITE ELECTRICAL DEMO

195 ES-101A-O

PT

SITE ELEC - DEMO PLAN - BLDG 630

196 ES-102A SITE ELEC - NEW WORK - VMF FACILITY

197 ES-102A-O

PT

SITE ELEC - NEW WORK - BLDG 631 & VMF FACILITY W/

OPTION BID ITEMS

198 ES-102B-O

PT

SITE ELEC - SITE WORK, BLDG 563-580- 836 - OPTION BID

ITEMS 5,6,7

199 ES-102C-O

PT

SITE ELEC - SITE WORK B.1090 - OPTION BID ITEM 4

200 ES-103 ELECTRICAL SITE PLAN - K-PLANT DISTRIBUTION

201 ES-104 SITE ELEC - HEAT TRACING PLAN

202 ES-501 SITE ELECTRICAL DETAILS DETAILS 1

203 ES-502 SUBSTATION LAYOUT AND DETAILS

204 ES-503 SITE ELEC DETAILS - EXISTING PHOTOS 2 - ABOVE GROUND

CABLES

205 ES-601 ELECTRICAL SITE DISTRIBUTION DIAGRAM

206 ES-602-OP

T

REVISED ONE-LINE DIAGRAM FOR K1-K9 DISTRIBUTION

DEMO OF B. 630 (OPTION BID)

207 ES-603-OP

T

REVISED ONE-LINE DIAGRAM FOR K10 DISTRIBUTION DEMO

OF B. 1090 (OPTION BID)

208 ES-604-OP

T

REVISED ONE-LINE DIAGRAM FOR M4-M5 DISTRIBUTION

DEMO OF B.563, 590, 836

209 ES-605 ELECTRICAL DEMO AND PHASING NOTES OPTION BID ITEM

210 EG-101 SITE GROUNDING LAYOUT

211 EG-102 BUILDING GROUNDING PLAN

212 EG-601 GROUNDING DIAGRAM & DETAILS

213 EL-101A FIRST FLOOR LIGHTING - PART PLAN - A

214 EL-101B FIRST FLOOR LIGHTING - PART PLAN - B

215 EL-101C FIRST FLOOR LIGHTING - PART PLAN - C (OPTION)

216 EL-101D FIRST FLOOR MEZZANINE LIGHTING - PART PLAN

217 EL-102A SECOND FLOOR LIGHTING - PART PLAN A (2ND FLOOR

PLAN)

218 EL-102B SECOND FLOOR LIGHTING - PART PLAN - CATWALK AREAS

219 EL-103 ROOF LIGHTING PLAN

220 EL-401 ELEVATION - MTD HEIGHTS

221 EL-501 LIGHTING FIXTURES SCHEDULE AND DETAILS

222 EL-502 LIGHTING CONTROL DETAILS

223 EL-504 SUPPORT STRUCTURE FOR LIGHTING SYSTEM

224 EL-505 LIGHTING FIXTURES MTD HEIGHTS - FIRST FLOOR

225 EL-601 LIGHTING CONTROL DIAGRAM

226 EP-101A FIRST FLOOR POWER - PART PLAN - A

227 EP-101A-M FIRST FLOOR POWER - PART PLAN - A - MECH LOADS

228 EP-101B FIRST FLOOR POWER - PART PLAN - B

229 EP-101B-M FIRST FLOOR POWER - PART PLAN - B - MECH LOADS

230 EP-101C FIRST FLOOR POWER -PART PLAN - C (OPTION BID ITEM 1)

DRAWING LIST

SHEET NO.

SHEET

NUMBER SHEET TITLE

81 A-522 TYPICAL DETAILS

82 A-523 CASE WORK

83 A-531 PARTITION TYPES

84 A-532 ENTRY SHELTER

85 A-601 DOOR SCHEDULE

86 A-602 DOOR TYPES

87 A-604 WINDOW TYPES

88 I-101 FIRST FLOOR FINISH PLAN

89 I-102 SECOND FLOOR FINISH PLAN

90 I-103 FIRST FLOOR SIGNAGE PLAN

91 I-104 SECOND FLOOR SIGNAGE PLAN

92 I-105 FIRST FLOOR FURNITURE PLAN - PART A

93 I-106 SECOND FLOOR FURNITURE PLAN - PART A

94 I-201 INTERIOR ELEVATIONS

95 I-202 INTERIOR ELEVATIONS

96 I-203 INTERIOR ELEVATIONS

97 I-401 ENLARGED FURNITURE PLANS

98 I-402 ENLARGED FURNITURE PLANS

99 I-501 INTERIOR DETAILS

100 I-502 EXTERIOR DETAILS

101 I-601 INTERIOR MATERIALS FINISH SCHEDULE

102 I-602 SIGNAGE & WINDOW TREATMENT SCHEDULE

103 I-611 ROOM FINISH SCHEDULE

104 Q-101 EQUIPMENT LAYOUT

105 Q-102 EQUIPMENT LAYOUT

106 Q-103 EQUIPMENT LAYOUT

107 Q-601 EQUIPMENT SCHEDULE

108 Q-602 EQUIPMENT SCHEDULE

109 S-001 STRUCTURAL GENERAL NOTES

110 S-002 STRUCTURAL SYMBOLS & SCHEDULES

111 S-101 FOUNDATION & FIRST FLR PLAN - OVERVALL

112 S-101A FOUNDATION & FIRST FLR PLAN - PART A

113 S-101B FOUNDATION & FIRST FLR PLAN - PART B

114 S-101C FOUNDATION & FIRST FLR PLAN - PART C

115 S-102 SECOND FLR FRAMING PLAN - OVERALL

116 S-102A SECOND FLR FRAMING PLAN - PART A

117 S-102B SECOND FLR FRAMING PLAN - PART B

118 S-102C SECOND FLR FRAMING PLAN - PART C

119 S-103 ROOF FRAMING PLAN - OVERALL

120 S-103A ROOF FRAMING PLAN - PART A

121 S-103B ROOF FRAMING PLAN - PART B

122 S-103C ROOF FRAMING PLAN - PART C

123 S-201 FRAMING ELEVATIONS

124 S-202 FRAMING ELEVATIONS

125 S-203 FRAMING ELEVATIONS

126 S-204 GIRT ELEVATIONS

127 S-205 GIRT ELEVATIONS

128 S-401 ISOMETRIC VIEWS

129 S-402 ISOMETRIC VIEWS

130 S-501 TYPICAL FOUNDATION DETAILS

131 S-502 TYPICAL FOUNDATION DETAILS

132 S-503 FOUNDATION DETAILS

133 S-504 FOUNDATION DETAILS

134 S-505 FOUNDATION DETAILS

135 S-506 FOUNDATION DETAILS

136 S-507 MAINTENANCE PIT DETAILS

137 S-508 TYPICAL DETAILS

138 S-509 TYPICAL DETAILS

139 S-510 TYPICAL DETAILS

140 S-511 TYPICAL DETAILS

141 S-512 TYPICAL WIND GIRT DETAILS

142 S-513 DETAILS

143 S-514 DETAILS

144 S-515 DETAILS

145 S-516 PORCH DETAILS

146 S-517 OPTION AREA DETAILS

147 S-601 STRUCTURAL COLUMN SCHEDULE

148 S-602 STRUCTURAL COLUMN SCHEDULE

149 S-603 BASE PLATE PLAN

150 M-001 MECHANICAL NOTES, SYMBOLS AND ABBREVIATIONS

151 M-101 MECHANICAL FIRST FLOOR PLAN - DUCTWORK

152 M-101A MECHANICAL FIRST FLOOR PLAN - PART A DUCTWORK

153 M-101B MECHANICAL FIRST FLOOR PLAN - PART B DUCTWORK

154 M-101C MECHANICAL FIRST FLOOR PLAN - PART C DUCTWORK

155 M-102 MECHANICAL FIRST FLOOR PLAN - PIPING

156 M-102A MECHANICAL FIRST FLOOR PLAN - PART A PIPING

157 M-102B MECHANICAL FIRST FLOOR PLAN - PART B PIPING

158 M-102C MECHANICAL FIRST FLOOR PLAN - PART C PIPING

159 M-103 MECHANICAL SECOND FLOOR PLAN - DUCTWORK

160 M-103A MECHANICAL SECOND FLOOR PLAN - PART A - DUCTWORK

DRAWING LIST

SHEET NO.

SHEET

NUMBER SHEET TITLE

1 G-001 COVER SHEET

2 G-002 DRAWING LIST

3 G-003 ABBREVIATIONS, SYMBOLS, PROJECT LOCATION MAPS

4 G-004 LIFE SAFETY FIRST FLOOR PLAN

5 G-005 LIFE SAFETY SECOND FLOOR PLAN

6 C-101 EXISTING SITE CONDITIONS PLAN

7 C-102 DEMOLITION PLAN - OVERALL VIEW

8 C-103 DEMOLITION PLAN - LOCATION #1

9 C-104 DEMOLITION PLAN - LOCATION #2

10 C-105 DEMOLITION PLAN - LOCATION #3

11 C-106 DEMOLITION PLAN - LOCATION #4

12 C-107 DEMOLITION PLAN - LOCATION #5

13 C-108 DEMOLITION PLAN - LOCATION #6

14 C-109 EXCAVATION PLAN

15 C-109A EXCAVATION PLAN - OPTION #1

16 C-110 NEW SITE PLAN - SHEET #1

17 C-110A NEW SITE PLAN - OPTION #1 - SHEET #1

18 C-111 NEW SITE PLAN - SHEET #2

19 C-111A NEW SITE PLAN - OPTION #1 - SHEET #2

20 C-112 EROSION & SEDIMENT CONTROL PLAN - SHEET #1

21 C-113 EROSION & SEDIMENT CONTROL PLAN - SHEET #2

22 C-301 UTILITY PLAN - SHEET #1

23 C-302 UTILITY PLAN - SHEET #2

24 C-302A UTILITY PLAN - OPTION #1 - SHEET #2

25 C-303 UTILITY PLAN - SHEET #3

26 C-304 EXCAVATION NOTES

27 C-305 THERMISTOR PROFILES

28 C-306 DETAILED UTILITY VIEW

29 C-307 SITE PROFILES

30 C-501 UTILITY DETAILS SHEET #1

31 C-502 UTILITY DETAILS SHEET #2

32 C-503 SITE DETAILS SHEET #1

33 C-504 SITE DETAILS SHEET #2

34 B-101 GEOTECHNICAL DATA

35 A-101 FIRST FLOOR PLAN

36 A-102 FIRST FLOOR PLAN (OPTION 1)

37 A-111 FIRST FLOOR PLAN - PART A

38 A-112 FIRST FLOOR PLAN - PART B

39 A-113 FIRST FLOOR PLAN - PART C (OPTION 1)

40 A-121 SECOND FLOOR PLAN

41 A-122 SECOND FLOOR PLAN (OPTION 1)

42 A-131 SECOND FLOOR PLAN - PART A

43 A-132 SECOND FLOOR PLAN - PART B

44 A-133 SECOND FLOOR PLAN - PART C (OPTION 1)

45 A-141 ROOF PLAN

46 A-142 ROOF PLAN (OPTION 1)

47 A-151 FIRST FLOOR - REFLECTED CEILING PLAN

48 A-152 FIRST FLOOR - REFLECTED CEILING PLAN (OPTION 1)

49 A-161 SECOND FLOOR - REFLECTED CEILING PLAN

50 A-162 SECOND FLOOR - REFLECTED CEILING PLAN (OPTION 1)

51 A-201 NORTH & SOUTH ELEVATIONS

52 A-202 NORTH ELEVATION (OPTION 1)

53 A-211 NORTH ELEVATION - PART B

54 A-212 NORTH ELEVATION - PART A

55 A-213 NORTH ELEVATION PART C (OPTION 1)

56 A-214 SOUTH ELEVATION - PART A

57 A-215 SOUTH ELEVATION - PART B

58 A-216 EAST & WEST ELEVATIONS

59 A-217 EAST & WEST ELEVATIONS (OPTION 1)

60 A-301 LONGITUDINAL SECTION

61 A-302 LONGITUDINAL SECTION

62 A-303 LONGITUDINAL SECTION

63 A-304 LONGITUDINAL SECTION

64 A-305 LONGITUDINAL SECTION (OPTION 1)

65 A-311 CROSS SECTION

66 A-312 CROSS SECTION

67 A-313 CROSS SECTION (OPTION 1)

68 A-314 CROSS SECTION - PART B (OPTION 1)

69 A-401 ENLARGED PLANS

70 A-402 ENLARGED PLANS

71 A-421 ENLARGED STAIR PLANS & SECTIONS

72 A-422 ENLARGED STAIR & RAMP

73 A-501 WALL SECTIONS

74 A-502 ROOF SECTIONS

75 A-503 WALL SECTIONS (OPTION 1)

76 A-511 EXTERIOR PLAN DETAILS

77 A-513 EXTERIOR PLAN DETAILS - PART C (OPTION 1)

78 A-514 INTERIOR PLAN DETAILS

79 A-516 INTAKE & EXHAUST HOOD DETAILS

80 A-521 TYPICAL DETAILS

UP

UP

A-216 2

A-2161

14131211107 8654321

E

D

F

A-301

A-312

A-302

A-311

A-112

FUEL

TRUCK

BAY

AF

VEHICLES

HEAVY

EQUIP

GENERAL

PURPOSE

VEHICLES

RECEPTION

PAINT BAY

BODY

SHOP

400 7800 7800 7800 9000 9000 7800 7800 500 10000 10500 10500 10500 13900 12000 400

125700

P&G

STORAGE

WASH BAY

FIRE

PUMP

ROOM

TIRE

STORAGE

TOOLS &

PARTS

CORRIDOR

WOMEN'S

TOILET

MEN'S

TOILET

MEN'S

TOILET

STORAGE

JANITOR

VEST

VEST

VEST

STAIR

STAIR

VEST

VEST

VEST

VEST

VEST

VEST

VEST

VEST

UTILITY

BAY

A-111

A-201

A-314

D.1

E.1

E.2

A-201

M

AT

C H

LI

N

E

SE

E A-

M

AT

C H

LI

N

E

SE

E A-

8.1

ELEC

PANEL

A-303

A-304

PART A PART B

GENERAL NOTES:

TOTAL GROSS AREA = 3718.5 SQM

1. REFER TO SHEET G-003 FOR SYMBOLS AND ABBREVIATIONS.

2. REFER TO SHEET A-531 FOR WALL PARTITION TYPES.

3. REFER TO SHEETS A-601 tTHROUGH A-603 FOR DOOR SCHEDULE, DOOR & FRAME TYPES, AND DETAILS.

4. REFER TO SHEET A-604 FOR WINDOW ELEVATIONS AND DETAILS.

5. REFER TO SHEET I-611 FOR ROOM FINISH SCHEDULE.

6. REFER TO CID PACKAGE UNDER A SEPARATE COVER FOR FURNITURE PLACEMENT.

7. ALL EXTERIOR WALLS TO MAINTAIN AN R-VALUE OF R-64.43 ft2·°F·h / (BTU).

8. NONE OF THE BUILDINGS AT THULE AIR BASE ARE REQUIRED TO COMPLY WITH THE US ACCESS BOARD, AMERICANS WITH DISABILITIES ACT GUIDELINES.

9. REFER TO STRUCTURAL DRAWINGS FOR FLOOR SLOPES.

10. REFER TO PART PLANS AT 1:100 FOR KEYNOTES AND DETAILED DIMENSIONS.

11. PROVIDE CONTROL JOINTS IN GYPSUM BOARD AT EVERY 20' OF WALL OR FLOOR IN THE X AND Z DIRECTIONS.

METAL GRATE

MATERIALS LEGEND:

US Army Corps of Engineers New York District

SY

M

BO

L

R

EV

IS

IO

N D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

U

.S .A

R M

Y C

O R

PS

O

FE

N

G

IN

EE

R

S N

EW

Y

O R

K D

IS

TR

IC

T ht tp w w w

.n an

.u sa ce .a rm y.

m il

SHEET

REFERENCE

NUMBER:

DATE:

FILE PATH:

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

F

ED

ER

AL

P

LA

ZA

R O

O M

N

EW

Y

O R

K, N

Y

8-

A N

SI

D

DA

TE

SO

LI

C

IT

A

TI

O N

N O

C O

N

TR

A C

T N

O

FI

LE

N U

M B

ER

FI

LE

N A

M E:

PL

O

T D

A

TE

C K

D B

Y:

D

W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B

M

IT

TE

D

B Y:

PL

O

T

SC

A

LE

SI

ZE

PR

O

JE

CT

S

TA

TU

S:

TH

U

LE

A

IR

B

AS

E

G R

EE

N

LA

N

D

TH

U

LE

C O

N

SO

LI

D

AT

ED

W

2D S-

-B

-0

C:\Users\E3ENDCPP\Documents\ARCH_C2_E3ENDCPP.rvt

3/26/2014 9:27:04 AM

AM

EN

D

M

EN

T

3/

/1

A s in di ca te d

A-101

FI

R

ST

F

LO

O

R P

LA

N

M

AR

C

H

N M

W

N M

W M

AJ

AM

EN

D M

EN

T

1 : 200A-101A-201

FIRST FLOOR PLAN1

N

TRUE NORTH

WIND

PLAN NORTH

0 10,000MM 20,000MM

SCALE 1:200 (MILLIMETERS)

UP

A-112

A-113

FUEL

TRUCK

BAY

AF

VEHICLES

HEAVY

EQUIP

GENERAL

PURPOSE

VEHICLES

RECEPTION

PAINT BAY

BODY

SHOP

14131211107 8654321

E

D

F

A-301

B

C

A

400 7800 7800 7800 9000 9000 7800 7800 500 10000 10500 10500 10500 13900 12000 400

125700

P&G

STORAGE

WASH BAY

FIRE

PUMP

ROOM

TIRE

STORAGE

TOOLS &

PARTS

CORRIDOR

WOMEN'S

TOILET

MEN'S

TOILET

MEN'S

TOILET

STORAGE

JANITOR

VEST

VEST

VEST

STAIR

STAIR

VEST

VEST

VEST

VEST

VEST

VEST

VEST

A-305

A-312

A-2171

A-217 2

UTILITY

BAY

A-302

SNOW

REMOVAL

A-311

A-202

A-111

VEST

VEST

7800 50000 67900

D.1

E.1

E.2

A-201

A-314

A-313

M

AT

C H

LI

N

E

SE

E A-

M

AT

C H

LI

N

E

SE

E A-

MATCHLINE SEE A-113

MATCHLINE SEE A-111

8.1

C.9

A-303

A-304

400 49200 400

PART A PART B

PART CMETAL GRATE

MATERIALS LEGEND:

GENERAL NOTES:

TOTAL GROSS AREA = 3718.5 SQM

1. REFER TO SHEET G-003 FOR SYMBOLS AND ABBREVIATIONS.

2. REFER TO SHEET A-531 FOR WALL PARTITION TYPES.

3. REFER TO SHEETS A-601 tTHROUGH A-603 FOR DOOR SCHEDULE, DOOR & FRAME TYPES, AND DETAILS.

4. REFER TO SHEET A-604 FOR WINDOW ELEVATIONS AND DETAILS.

5. REFER TO SHEET I-611 FOR ROOM FINISH SCHEDULE.

6. REFER TO CID PACKAGE UNDER A SEPARATE COVER FOR FURNITURE PLACEMENT.

7. ALL EXTERIOR WALLS TO MAINTAIN AN R-VALUE OF R-64.43 ft2·°F·h / (BTU).

8. NONE OF THE BUILDINGS AT THULE AIR BASE ARE REQUIRED TO COMPLY WITH THE US ACCESS BOARD, AMERICANS WITH DISABILITIES ACT GUIDELINES.

9. REFER TO STRUCTURAL DRAWINGS FOR FLOOR SLOPES.

10. REFER TO PART PLANS AT 1:100 FOR KEYNOTES AND DETAILED DIMENSIONS.

11. PROVIDE CONTROL JOINTS IN GYPSUM BOARD AT EVERY 20' OF WALL OR FLOOR IN THE X AND Z DIRECTIONS.

US Army Corps of Engineers New York District

SY

M

BO

L

R

EV

IS

IO

N D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

U

.S .A

R M

Y C

O R

PS

O

FE

N

G

IN

EE

R

S N

EW

Y

O R

K D

IS

TR

IC

T ht tp w w w

.n an

.u sa ce .a rm y.

m il

SHEET

REFERENCE

NUMBER:

DATE:

FILE PATH:

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

F

ED

ER

AL

P

LA

ZA

R O

O M

N

EW

Y

O R

K, N

Y

8-

A N

SI

D

DA

TE

SO

LI

C

IT

A

TI

O N

N O

C O

N

TR

A C

T N

O

FI

LE

N U

M B

ER

FI

LE

N A

M E:

PL

O

T D

A

TE

C K

D B

Y:

D

W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B

M

IT

TE

D

B Y:

PL

O

T

SC

A

LE

SI

ZE

PR

O

JE

CT

S

TA

TU

S:

TH

U

LE

A

IR

B

AS

E

G R

EE

N

LA

N

D

TH

U

LE

C O

N

SO

LI

D

AT

ED

W

2D S-

-B

-0

C:\Users\E3ENDCPP\Documents\ARCH_C2_E3ENDCPP.rvt

3/26/2014 9:27:13 AM

AM

EN

D

M

EN

T

3/

/1

A s in di ca te d

A-102

FI

R

ST

F

LO

O

R P

LA

N

(O

PT

IO

N

M

AR

C

H

D es ig ne r

A ut ho r

C he ck er

AM

EN

D M

EN

T

1 : 200A-102A-201

FIRST FLOOR PLAN (OPTION 1)1

N

TRUE NORTH

WIND

PLAN NORTH

0 10,000MM 20,000MM

SCALE 1:200 (MILLIMETERS)

CHANGES

MADE TO THIS

DRAWING

WERE FOR

CLARITY ONLY.

UP

M

AT

C H

LI

N

E

SE

E A-

MATCHLINE

SEE A-113

RECEPTION

PAINT BAY

BODY

SHOP

A-214

7 8654321

E

D

F

1300 6000 1945 910 35690 910 9290 910 445 500

6000 1800 6000 1800 6000 1800 6000 3145 910 16945 1200 4500

57400

8549 2292

TIRE

STORAGE

P&G

STORAGE

TOOLS &

PARTS

VEST

STAIR

STAIR

VEST

FIRE

PUMP

ROOM

CORRIDOR

WASH BAY

VEST

VEST

VEST

A-216 2

Q-101

Q-102

Q-101

A-421

A-421

A-511

A-514

A-511

A-511

A-514

A-514

A-514

A-514

A-302

121A 121B

120S

120N

119S 118S 115S

117A

114W

102 101A

110 109 108 107

103E

103B103A

104E104W

111A

A

A-311

B1

B

B1

B1

B

B

B

GB

B B

B1

B1

BB

B

B

AA A AA

AA

G

G

10-1

A-314

A-2171

MEZZ. ABOVE

FS

CR

CR

OR

22.03

10-2

D.1

E.1

E.2

FCO

FCO

FCO

FCO

G1

B1

G1

B1

B1

G1

G G

8.1

ELEC

PANEL

A

400 900

900 900 900 900 900 900 900 2100 1045 2100 2100

22.30

A-511

A-401

A-303

A-523

118E

285 7708 15494 8855 3232 317 8447 2665 10472

1027 1174

2345 4668 2334 4079

A-511

A-511

A-511

A-511

D

D

112A

116A 116B

22.31

FCO

GENERAL NOTES:

TOTAL GROSS AREA = 3718.5 SQM

1. REFER TO SHEET G-003 FOR SYMBOLS AND ABBREVIATIONS.

2. REFER TO SHEET A-531 FOR WALL PARTITION TYPES.

3. REFER TO SHEETS A-601 tTHROUGH A-603 FOR DOOR SCHEDULE, DOOR & FRAME TYPES, AND DETAILS.

4. REFER TO SHEET A-604 FOR WINDOW ELEVATIONS AND DETAILS.

5. REFER TO SHEET I-611 FOR ROOM FINISH SCHEDULE.

6. REFER TO CID PACKAGE UNDER A SEPARATE COVER FOR FURNITURE PLACEMENT.

7. ALL EXTERIOR WALLS TO MAINTAIN AN R-VALUE OF R-64.43 ft2·°F·h / (BTU).

8. NONE OF THE BUILDINGS AT THULE AIR BASE ARE REQUIRED TO COMPLY WITH THE US ACCESS BOARD, AMERICANS WITH DISABILITIES ACT GUIDELINES.

9. REFER TO STRUCTURAL DRAWINGS FOR FLOOR SLOPES.

10. REFER TO PART PLANS AT 1:100 FOR KEYNOTES AND DETAILED DIMENSIONS.

11. PROVIDE CONTROL JOINTS IN GYPSUM BOARD AT EVERY 20' OF WALL OR FLOOR IN THE X AND Z DIRECTIONS.

PART A PART B

1t10-1 CAR WASH

PRESSURE WASHER

PAINT BOOTH

1Mx1M CRATE

FLAMMABLE STORAGE CABINET

OIL RACK (2 SHELVES)

1t11-1

1tCR

1tFS

1tOR

EQUIPMENT & CASEWORK LEGEND:

1t10-2

22.03 TRENCH BASIN

FORKLIFT CHARGER

SWEEPER CHARGER

KEYNOTES:

22.30

22.31

METAL GRATE

MATERIALS LEGEND:

US Army Corps of Engineers New York District

SY

M

BO

L

R

EV

IS

IO

N D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

U

.S .A

R M

Y C

O R

PS

O

FE

N

G

IN

EE

R

S N

EW

Y

O R

K D

IS

TR

IC

T ht tp w w w

.n an

.u sa ce .a rm y.

m il

SHEET

REFERENCE

NUMBER:

DATE:

FILE PATH:

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

F

ED

ER

AL

P

LA

ZA

R O

O M

N

EW

Y

O R

K, N

Y

8-

A N

SI

D

DA

TE

SO

LI

C

IT

A

TI

O N

N O

C O

N

TR

A C

T N

O

FI

LE

N U

M B

ER

FI

LE

N A

M E:

PL

O

T D

A

TE

C K

D B

Y:

D

W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B

M

IT

TE

D

B Y:

PL

O

T

SC

A

LE

SI

ZE

PR

O

JE

CT

S

TA

TU

S:

TH

U

LE

A

IR

B

AS

E

G R

EE

N

LA

N

D

TH

U

LE

C O

N

SO

LI

D

AT

ED

W

2D S-

-B

-0

C:\Users\E3ENDCPP\Documents\ARCH_C2_E3ENDCPP.rvt

3/26/2014 9:27:16 AM

AM

EN

D

M

EN

T

3/

/1

A s in di ca te d

A-111

FI

R

ST

F

LO

O

R P

LA

N

PA

R T

A

M

AR

C

H

N M

W

N M

W M

J

AM

EN

D M

EN

T

1 : 100A-111A-101

FIRST FLOOR PLAN - PART A1

N

TRUE NORTH

WIND

PLAN NORTH

0 5,000MM 10,000MM

SCALE 1:100 (MILLIMETERS)

CHANGES

MADE TO THIS

DRAWING

WERE FOR

MATCHLINE

SEE A-113

M

AT

C H

LI

N

E

SE

E A-

HEAVY

EQUIP

AF

VEHICLES

FUEL

TRUCK

BAY

GENERAL

PURPOSE

VEHICLES

14131211108

E

D

F

A-301

10847 6000 1175 378 1838 3810 6000 2400 6000 3144 399 1838 3620 6000 1922 1678 6000 1993 2397

VEST

VEST

VEST

VEST

VEST

VEST

UTILITY

BAY

10600 6000 1945 910 4345 6000 2400 6000 3745 910 4345 6000 3600 6000 2545 910 1545

11100 6000 1945 910 4345 6000 2400 6000 3745 910 4345 6000 3600 6000 2545 910 1545

68300

A-211

A-2161

A-312

Q-103

Q-103

A-511

A-511

122S 123S

124A

125A

123N

129A

127N126N 130N

132A

130S127S

128A

126S

131A

122N

B1

B1

B1

B1

B1

B1

B1

B1

G1

G B1

G1

B1 G

G1

G B1

G1

G

G1

G

B1

B1

F1

OR2

OR2

Q-101

D.1

E.1

E.2

A-215

G1

B1

G1

B1

B1

G1

8.1

C.9

FCO

FCO

FCO

FCO

FCO

FCOFCO

1200 1200 3300 445 2200 1400 2545 2055 400

600 1200 1200 3300 445 2200 1400 4600 4001045 3300

1045 3300

22.31 22.30

22.20

22.21

A-304

2-9

A-532

500 10000 10500 10500 10500 13900 12000 400

5.88

ABOVE

TB

A-511

FCO

GENERAL NOTES:

TOTAL GROSS AREA = 3718.5 SQM

1. REFER TO SHEET G-003 FOR SYMBOLS AND ABBREVIATIONS.

2. REFER TO SHEET A-531 FOR WALL PARTITION TYPES.

3. REFER TO SHEETS A-601 tTHROUGH A-603 FOR DOOR SCHEDULE, DOOR & FRAME TYPES, AND DETAILS.

4. REFER TO SHEET A-604 FOR WINDOW ELEVATIONS AND DETAILS.

5. REFER TO SHEET I-611 FOR ROOM FINISH SCHEDULE.

6. REFER TO CID PACKAGE UNDER A SEPARATE COVER FOR FURNITURE PLACEMENT.

7. ALL EXTERIOR WALLS TO MAINTAIN AN R-VALUE OF R-64.43 ft2·°F·h / (BTU).

8. NONE OF THE BUILDINGS AT THULE AIR BASE ARE REQUIRED TO COMPLY WITH THE US ACCESS BOARD, AMERICANS WITH DISABILITIES ACT GUIDELINES.

9. REFER TO STRUCTURAL DRAWINGS FOR FLOOR SLOPES.

10. REFER TO PART PLANS AT 1:100 FOR KEYNOTES AND DETAILED DIMENSIONS.

11. PROVIDE CONTROL JOINTS IN GYPSUM BOARD AT EVERY 20' OF WALL OR FLOOR IN THE X AND Z DIRECTIONS.

PART A PART B

1t OIL RACK (3 SHELVES)

6-TON DOUBLE-GIRDER CRANE

TOOL BOX

OR2

EQUIPMENT & CASEWORK LEGEND:

1t2-9

1tTB

22.03

PAINTED CONCRETE FILLED

BOLLARD

TRENCH BASIN

PREFABRICATED WORK TRENCH

OIL/WATER SEPARATOR & WASTE

OIL TANK CRYPT WITH HINGED

METAL ACCESS PANELS

FORKLIFT CHARGER

SWEEPER CHARGER

KEYNOTES:

22.20

22.21

22.30

22.31

5.88

METAL GRATE

MATERIALS LEGEND:

US Army Corps of Engineers New York District

SY

M

BO

L

R

EV

IS

IO

N D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

U

.S .A

R M

Y C

O R

PS

O

FE

N

G

IN

EE

R

S N

EW

Y

O R

K D

IS

TR

IC

T ht tp w w w

.n an

.u sa ce .a rm y.

m il

SHEET

REFERENCE

NUMBER:

DATE:

FILE PATH:

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

F

ED

ER

AL

P

LA

ZA

R O

O M

N

EW

Y

O R

K, N

Y

8-

A N

SI

D

DA

TE

SO

LI

C

IT

A

TI

O N

N O

C O

N

TR

A C

T N

O

FI

LE

N U

M B

ER

FI

LE

N A

M E:

PL

O

T D

A

TE

C K

D B

Y:

D

W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B

M

IT

TE

D

B Y:

PL

O

T

SC

A

LE

SI

ZE

PR

O

JE

CT

S

TA

TU

S:

TH

U

LE

A

IR

B

AS

E

G R

EE

N

LA

N

D

TH

U

LE

C O

N

SO

LI

D

AT

ED

W

2D S-

-B

-0

C:\Users\E3ENDCPP\Documents\ARCH_C2_E3ENDCPP.rvt

3/26/2014 9:27:20 AM

AM

EN

D

M

EN

T

3/

/1

A s in di ca te d

A-112

FI

R

ST

F

LO

O

R P

LA

N

PA

R T

B

M

AR

C

H

N M

W

A ut ho r

M J

AM

EN

D M

EN

T

1 : 100A-112A-101

FIRST FLOOR PLAN - PART B1

N

TRUE NORTH

WIND

PLAN NORTH

0 5,000MM 10,000MM

SCALE 1:100 (MILLIMETERS)

CHANGES

MADE TO THIS

DRAWING

WERE FOR

MATCHLINE

SEE A-111

7 8654321

D

B

C

A

7800 7800 7800 9000 9000 7800 7800 500

50000

A-305

5 18

134 134B 135B 135

133A

133B

133C 133D

133E

133F

A-513

SNOW

REMOVAL

B1B1

BB

A-2171

400 285 2225 33517 12888 285 400

10-2

A-217 2

A-213

8.1

C.9

400 900

A-513

A-513

7800 7800 7800 9000 9000 7800 7800 500

A-513

5.88

TYP.

TYP.

5.88

22.02

22.02

VEST

VEST

134 A-513

420 420

PART C

PART A PART B

GENERAL NOTES:

TOTAL GROSS AREA = 3718.5 SQM

1. REFER TO SHEET G-003 FOR SYMBOLS AND ABBREVIATIONS.

2. REFER TO SHEET A-531 FOR WALL PARTITION TYPES.

3. REFER TO SHEETS A-601 tTHROUGH A-603 FOR DOOR SCHEDULE, DOOR & FRAME TYPES, AND DETAILS.

4. REFER TO SHEET A-604 FOR WINDOW ELEVATIONS AND DETAILS.

5. REFER TO SHEET I-611 FOR ROOM FINISH SCHEDULE.

6. REFER TO CID PACKAGE UNDER A SEPARATE COVER FOR FURNITURE PLACEMENT.

7. ALL EXTERIOR WALLS TO MAINTAIN AN R-VALUE OF R-64.43 ft2·°F·h / (BTU).

8. NONE OF THE BUILDINGS AT THULE AIR BASE ARE REQUIRED TO COMPLY WITH THE US ACCESS BOARD, AMERICANS WITH DISABILITIES ACT GUIDELINES.

9. REFER TO STRUCTURAL DRAWINGS FOR FLOOR SLOPES.

10. REFER TO PART PLANS AT 1:100 FOR KEYNOTES AND DETAILED DIMENSIONS.

11. PROVIDE CONTROL JOINTS IN GYPSUM BOARD AT EVERY 20' OF WALL OR FLOOR IN THE X AND Z DIRECTIONS.

5.88 CONC. FILLED MTL. BOLLARD

TRENCH DRAIN

KEYNOTES:

22.02

PRESSURE WASHER

EQUIPMENT & CASEWORK LEGEND:

1t10-2

US Army Corps of Engineers New York District

SY

M

BO

L

R

EV

IS

IO

N D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

U

.S .A

R M

Y C

O R

PS

O

FE

N

G

IN

EE

R

S N

EW

Y

O R

K D

IS

TR

IC

T ht tp w w w

.n an

.u sa ce .a rm y.

m il

SHEET

REFERENCE

NUMBER:

DATE:

FILE PATH:

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

F

ED

ER

AL

P

LA

ZA

R O

O M

N

EW

Y

O R

K, N

Y

8-

A N

SI

D

DA

TE

SO

LI

C

IT

A

TI

O N

N O

C O

N

TR

A C

T N

O

FI

LE

N U

M B

ER

FI

LE

N A

M E:

PL

O

T D

A

TE

C K

D B

Y:

D

W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B

M

IT

TE

D

B Y:

PL

O

T

SC

A

LE

SI

ZE

PR

O

JE

CT

S

TA

TU

S:

TH

U

LE

A

IR

B

AS

E

G R

EE

N

LA

N

D

TH

U

LE

C O

N

SO

LI

D

AT

ED

W

2D S-

-B

-0

C:\Users\E3ENDCPP\Documents\ARCH_C2_E3ENDCPP.rvt

3/26/2014 9:27:22 AM

AM

EN

D

M

EN

T

3/

/1

A s in di ca te d

A-113

FI

R

ST

F

LO

O

R P

LA

N

PA

R T

C (O

PT

IO

N

M

AR

C

H

D es ig ne r

A ut ho r

C he ck er

AM

EN

D M

EN

T

1 : 100A-113A-102

FIRST FLOOR PLAN - PART C (OPTION 1)1

N

TRUE NORTH

WIND

PLAN NORTH

0 5,000MM 10,000MM

SCALE 1:100 (MILLIMETERS)

CHANGES

MADE TO THIS

DRAWING

WERE FOR

DN

24" (61 CM)

24"

24"

B

DN

A-216 2

A-2161

A-201

14131211107 8654321

E

D

F

A-301

A-312

A-302

A-311

A-131

A-132

MECH

CATWALK

BREAK /

KITCH

ELEC

TEL

MEN'S

SHOWERS

MEN'S

TOILET

MEN'S

LOCKERS

MECH

CATWALK

STORAGE

OPEN

OFFICE

MECH. RM

OFFICE

STAIR

STAIR

JANITOR

CORRIDOR

WOMEN'S

TOILET &

LOCKER

ROOM

LAUNDRY

AREA

WOMEN'S

SHOWER

MEN'S

SHOWERS

MEN'S

SHOWERS

A-201

A-314

M

AT

C H

LI

N

E

SE

E A-

M

AT

C H

LI

N

E

SE

E A-

8.1

OPEN TO

BELOW

OPEN TO

BELOW

OPEN TO

BELOW

OPEN TO

BELOW

OPEN TO

BELOW

A-303

A-304

7800 7800 7800 9000 9000 7800 7800 500 10000 10500 10500 10500 13900 12000 400

125700

GENERAL NOTES:

TOTAL GROSS AREA = 3718.5 SQM

1. REFER TO SHEET G-003 FOR SYMBOLS AND ABBREVIATIONS.

2. REFER TO SHEET A-531 FOR WALL PARTITION TYPES.

3. REFER TO SHEETS A-601 tTHROUGH A-603 FOR DOOR SCHEDULE, DOOR & FRAME TYPES, AND DETAILS.

4. REFER TO SHEET A-604 FOR WINDOW ELEVATIONS AND DETAILS.

5. REFER TO SHEET I-611 FOR ROOM FINISH SCHEDULE.

6. REFER TO CID PACKAGE UNDER A SEPARATE COVER FOR FURNITURE PLACEMENT.

7. ALL EXTERIOR WALLS TO MAINTAIN AN R-VALUE OF R-64.43 ft2·°F·h / (BTU).

8. NONE OF THE BUILDINGS AT THULE AIR BASE ARE REQUIRED TO COMPLY WITH THE US ACCESS BOARD, AMERICANS WITH DISABILITIES ACT GUIDELINES.

9. REFER TO STRUCTURAL DRAWINGS FOR FLOOR SLOPES.

10. REFER TO PART PLANS AT 1:100 FOR KEYNOTES AND DETAILED DIMENSIONS.

11. PROVIDE CONTROL JOINTS IN GYPSUM BOARD AT EVERY 20' OF WALL OR FLOOR IN THE X AND Z DIRECTIONS.

PART A PART B

METAL GRATE

FAN

FAN

UNIT HEATER

AIR CURTAIN

LEGEND:

US Army Corps of Engineers New York District

SY

M

BO

L

R

EV

IS

IO

N D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

U

.S .A

R M

Y C

O R

PS

O

FE

N

G

IN

EE

R

S N

EW

Y

O R

K D

IS

TR

IC

T ht tp w w w

.n an

.u sa ce .a rm y.

m il

SHEET

REFERENCE

NUMBER:

DATE:

FILE PATH:

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

F

ED

ER

AL

P

LA

ZA

R O

O M

N

EW

Y

O R

K, N

Y

8-

A N

SI

D

DA

TE

SO

LI

C

IT

A

TI

O N

N O

C O

N

TR

A C

T N

O

FI

LE

N U

M B

ER

FI

LE

N A

M E:

PL

O

T D

A

TE

C K

D B

Y:

D

W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B

M

IT

TE

D

B Y:

PL

O

T

SC

A

LE

SI

ZE

PR

O

JE

CT

S

TA

TU

S:

TH

U

LE

A

IR

B

AS

E

G R

EE

N

LA

N

D

TH

U

LE

C O

N

SO

LI

D

AT

ED

W

2D S-

-B

-0

C:\Users\E3ENDCPP\Documents\ARCH_C2_E3ENDCPP.rvt

3/26/2014 9:27:31 AM

AM

EN

D

M

EN

T

3/

/1

A s in di ca te d

A-121

SE

C

O N

D F

LO

O

R P

LA

N

M

AR

C

H

D es ig ne r

A ut ho r

C he ck er

AM

EN

D M

EN

T

1 : 200A-121A-201

SECOND FLOOR PLAN1

N

TRUE NORTH

WIND

PLAN NORTH

0 10,000MM 20,000MM

SCALE 1:200 (MILLIMETERS)

CHANGES

MADE TO THIS

DRAWING

WERE FOR

DN

GENERAL NOTES:

TOTAL GROSS AREA = 3718.5 SQM

1. REFER TO SHEET G-003 FOR SYMBOLS AND ABBREVIATIONS.

2. REFER TO SHEET A-531 FOR WALL PARTITION TYPES.

3. REFER TO SHEETS A-601 tTHROUGH A-603 FOR DOOR SCHEDULE, DOOR & FRAME TYPES, AND DETAILS.

4. REFER TO SHEET A-604 FOR WINDOW ELEVATIONS AND DETAILS.

5. REFER TO SHEET I-611 FOR ROOM FINISH SCHEDULE.

6. REFER TO CID PACKAGE UNDER A SEPARATE COVER FOR FURNITURE PLACEMENT.

7. ALL EXTERIOR WALLS TO MAINTAIN AN R-VALUE OF R-64.43 ft2·°F·h / (BTU).

8. NONE OF THE BUILDINGS AT THULE AIR BASE ARE REQUIRED TO COMPLY WITH THE US ACCESS BOARD, AMERICANS WITH DISABILITIES ACT GUIDELINES.

9. REFER TO STRUCTURAL DRAWINGS FOR FLOOR SLOPES.

10. REFER TO PART PLANS AT 1:100 FOR KEYNOTES AND DETAILED DIMENSIONS.

11. PROVIDE CONTROL JOINTS IN GYPSUM BOARD AT EVERY 20' OF WALL OR FLOOR IN THE X AND Z DIRECTIONS.

PART A PART B

PART C

A-2161

A-201

14131211107 8654321

E

D

F

A-301

B

C

A

A-305

A-312

A-2171

A-217 2

A-302

A-311

A-131

A-132

A-133

MECH

CATWALK

BREAK /

KITCH

ELEC

TEL

MEN'S

SHOWERS

MEN'S

TOILET

MEN'S

LOCKERS

MECH

CATWALK

STORAGE

OPEN

OFFICE

MECH. RM

OFFICE

STAIR

STAIR

JANITOR

CORRIDOR

WOMEN'S

TOILET &

LOCKER

ROOM

LAUNDRY

AREA

WOMEN'S

SHOWER

215MEN'S

SHOWERS

MEN'S

SHOWERS

A-202

A-314

A-313

M

AT

C H

LI

N

E

SE

E A-

M

AT

C H

LI

N

E

SE

E A-

MATCHLINE SEE A-133

MATCHLINE SEE A-131

8.1

C.9

OPEN TO

BELOW

OPEN TO

BELOW

OPEN TO

BELOW

OPEN TO

BELOW

OPEN TO

BELOW

OPEN TO

BELOW

A-303

A-304

7800 7800 7800 9000 9000 7800 7800 500 10000 10500 10500 10500 13900 12000

A-521

METAL GRATE

FAN

FAN

UNIT HEATER

AIR CURTAIN

LEGEND:

US Army Corps of Engineers New York District

SY

M

BO

L

R

EV

IS

IO

N D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

U

.S .A

R M

Y C

O R

PS

O

FE

N

G

IN

EE

R

S N

EW

Y

O R

K D

IS

TR

IC

T ht tp w w w

.n an

.u sa ce .a rm y.

m il

SHEET

REFERENCE

NUMBER:

DATE:

FILE PATH:

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

F

ED

ER

AL

P

LA

ZA

R O

O M

N

EW

Y

O R

K, N

Y

8-

A N

SI

D

DA

TE

SO

LI

C

IT

A

TI

O N

N O

C O

N

TR

A C

T N

O

FI

LE

N U

M B

ER

FI

LE

N A

M E:

PL

O

T D

A

TE

C K

D B

Y:

D

W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B

M

IT

TE

D

B Y:

PL

O

T

SC

A

LE

SI

ZE

PR

O

JE

CT

S

TA

TU

S:

TH

U

LE

A

IR

B

AS

E

G R

EE

N

LA

N

D

TH

U

LE

C O

N

SO

LI

D

AT

ED

W

2D S-

-B

-0

C:\Users\E3ENDCPP\Documents\ARCH_C2_E3ENDCPP.rvt

3/26/2014 9:27:46 AM

AM

EN

D

M

EN

T

3/

/1

A s in di ca te d

A-122

SE

C

O N

D F

LO

O

R P

LA

N

(O

PT

IO

N

M

AR

C

H

D es ig ne r

A ut ho r

C he ck er

AM

EN

D M

EN

T

N

TRUE NORTH

WIND

PLAN NORTH

0 10,000MM 20,000MM

SCALE 1:200 (MILLIMETERS)

1 : 200A-122A-201

SECOND FLOOR PLAN (OPTION 1)1

CHANGES

MADE TO THIS

DRAWING

WERE FOR

24" (61 CM)

24"

24"

B

M

AT

C H

LI

N

E

SE

E A-

ELEC

TEL

MEN'S

SHOWERS

MEN'S

TOILET

MEN'S

LOCKERS

BREAK /

KITCH

STORAGE

STAIR

MECH

CATWALK

7 8654321

E

D

F

A-301

JANITOR

MECH. RM

OPEN

OFFICE

OFFICE

A-216 2

WOMEN'S

TOILET &

LOCKER

ROOM

WOMEN'S

SHOWER

LAUNDRY

AREA

STAIR

A-214

MEN'S

SHOWERS

MEN'S

SHOWERS

7285 5921 9576

3674 3627

2215 4633 2515

1384 2087

1173 3330

EQ

EQ

EQ

EQ

EQ

EQ

7122 1362 6102

CORRIDOR

33700 1200 22500

A-401

A-421

A-401

A-421

A-401

A-402

206A

203B

203A

208A

208B

206B

A-311

B

BB

BB

BB

B

BBB

B

B

B

BB

B

GGG

B

A

83 / 1000

23.03

AHU-3G

AHU-4G

A-212

A-314

8.1

99 / 1000 99 / 1000

A-303

99 / 1000 99 / 1000

99 / 100099 / 1000

A

400 7800 7800 7800 9000 9000 7800 7800 500

23.02

23.03 5.08 5.08

5.08

5.08

5.08 5.08

OPEN

TO

BELOW

OPEN

TO

BELOW

OPEN

TO

BELOW

A-516

IH-3G

IH-6G&7G

IH-4G

EH-3G

EH-4G 23.02

99 / 1000

GENERAL NOTES:

TOTAL GROSS AREA = 3718.5 SQM

1. REFER TO SHEET G-003 FOR SYMBOLS AND ABBREVIATIONS.

2. REFER TO SHEET A-531 FOR WALL PARTITION TYPES.

3. REFER TO SHEETS A-601 tTHROUGH A-603 FOR DOOR SCHEDULE, DOOR & FRAME TYPES, AND DETAILS.

4. REFER TO SHEET A-604 FOR WINDOW ELEVATIONS AND DETAILS.

5. REFER TO SHEET I-611 FOR ROOM FINISH SCHEDULE.

6. REFER TO CID PACKAGE UNDER A SEPARATE COVER FOR FURNITURE PLACEMENT.

7. ALL EXTERIOR WALLS TO MAINTAIN AN R-VALUE OF R-64.43 ft2·°F·h / (BTU).

8. NONE OF THE BUILDINGS AT THULE AIR BASE ARE REQUIRED TO COMPLY WITH THE US ACCESS BOARD, AMERICANS WITH DISABILITIES ACT GUIDELINES.

9. REFER TO STRUCTURAL DRAWINGS FOR FLOOR SLOPES.

10. REFER TO PART PLANS AT 1:100 FOR KEYNOTES AND DETAILED DIMENSIONS.

11. PROVIDE CONTROL JOINTS IN GYPSUM BOARD AT EVERY 20' OF WALL OR FLOOR IN THE X AND Z DIRECTIONS.

23.02

79MM CORRUGATED METAL ROOFING

ARCTIC EXHAUST HOOD

ARCTIC INTAKE HOOD

UNIT HEATER. REFER TO MECHANICAL DRAWINGS

KEYNOTES:

23.03

23.52

5.08

PART A PART B

METAL GRATE

FAN

FAN

UNIT HEATER

LEGEND:

AIR CURTAIN

WINDOW TAGT

US Army Corps of Engineers New York District

SY

M

BO

L

R

EV

IS

IO

N D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

U

.S .A

R M

Y C

O R

PS

O

FE

N

G

IN

EE

R

S N

EW

Y

O R

K D

IS

TR

IC

T ht tp w w w

.n an

.u sa ce .a rm y.

m il

SHEET

REFERENCE

NUMBER:

DATE:

FILE PATH:

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

F

ED

ER

AL

P

LA

ZA

R O

O M

N

EW

Y

O R

K, N

Y

8-

A N

SI

D

DA

TE

SO

LI

C

IT

A

TI

O N

N O

C O

N

TR

A C

T N

O

FI

LE

N U

M B

ER

FI

LE

N A

M E:

PL

O

T D

A

TE

C K

D B

Y:

D

W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B

M

IT

TE

D

B Y:

PL

O

T

SC

A

LE

SI

ZE

PR

O

JE

CT

S

TA

TU

S:

TH

U

LE

A

IR

B

AS

E

G R

EE

N

LA

N

D

TH

U

LE

C O

N

SO

LI

D

AT

ED

W

2D S-

-B

-0

C:\Users\E3ENDCPP\Documents\ARCH_C2_E3ENDCPP.rvt

3/26/2014 9:27:54 AM

AM

EN

D

M

EN

T

3/

/1

A s in di ca te d

A-131

SE

C

O N

D F

LO

O

R P

LA

N

PA

R T

A

M

AR

C

H

N M

W

N M

W M

AJ

AM

EN

D M

EN

T

1 : 100A-131A-121

SECOND FLOOR PLAN - PART A1

N

TRUE NORTH

WIND

PLAN NORTH

0 5,000MM 10,000MM

SCALE 1:100 (MILLIMETERS)

CHANGES

MADE TO THIS

DRAWING

WERE FOR

GENERAL NOTES:

TOTAL GROSS AREA = 3718.5 SQM

1. REFER TO SHEET G-003 FOR SYMBOLS AND ABBREVIATIONS.

2. REFER TO SHEET A-531 FOR WALL PARTITION TYPES.

3. REFER TO SHEETS A-601 tTHROUGH A-603 FOR DOOR SCHEDULE, DOOR & FRAME TYPES, AND DETAILS.

4. REFER TO SHEET A-604 FOR WINDOW ELEVATIONS AND DETAILS.

5. REFER TO SHEET I-611 FOR ROOM FINISH SCHEDULE.

6. REFER TO CID PACKAGE UNDER A SEPARATE COVER FOR FURNITURE PLACEMENT.

7. ALL EXTERIOR WALLS TO MAINTAIN AN R-VALUE OF R-64.43 ft2·°F·h / (BTU).

8. NONE OF THE BUILDINGS AT THULE AIR BASE ARE REQUIRED TO COMPLY WITH THE US ACCESS BOARD, AMERICANS WITH DISABILITIES ACT GUIDELINES.

9. REFER TO STRUCTURAL DRAWINGS FOR FLOOR SLOPES.

10. REFER TO PART PLANS AT 1:100 FOR KEYNOTES AND DETAILED DIMENSIONS.

11. PROVIDE CONTROL JOINTS IN GYPSUM BOARD AT EVERY 20' OF WALL OR FLOOR IN THE X AND Z DIRECTIONS.

14131211108

E

D

F

A-215

A-211

A-2161

A-312

10895 610 1790 610 1790 610 4195 3595 610 1790 610 1790 610 2990 610 1790 610 1790 610 3595 5995 610 1790 610 1790 610 2495 1695 610 1790 610 1790 610 4895 400

A-302

B B B B B B

A-402

2-9

MECH

CATWALK

8.1

M

AT

C H

LI

N

E

SE

E A-

5.08

A-304

A-532

99 / 1000

99 / 1000 BBBBBBBB B

35003500

5.08 5.08

23.02

TYP.,

U.N.O.

23.02

TYP.,

U.N.O.

22.21

5.08 5.08 5.08

23.53

TYP.

TYP.

23.54

TYP.

23.52

TYP.

MATCHLINE

SEE A-131

10000 10500 10500 10500 13900 12000

OPEN

TO

BELOW

164 / 1000

23.02

79MM CORRUGATED METAL ROOFING

PAINTED CONCRETE FILLED BOLLARD

OIL/WATER SEPARATOR & WASTE OIL TANK CRYPT

WITH HINGED METAL ACCESS PANELS

ARCTIC EXHAUST HOOD

ARCTIC INTAKE HOOD

UNIT HEATER. REFER TO MECHANICAL DRAWINGS

AIR CURTAIN. REFER TO MECHANICAL DRAWINGS

EXHAUST FAN. REFER TO MECHANICAL DRAWINGS

KEYNOTES:

23.52

23.53

5.08

23.03

22.21

23.54

5.88

PART A PART B

1t 6 TON DOUBLE-GIRDER CRANE2-9

EQUIPMENT & CASEWORK LEGEND:

METAL GRATE

FAN

FAN

UNIT HEATER

LEGEND:

AIR CURTAIN

WINDOW TAGT

US Army Corps of Engineers New York District

SY

M

BO

L

R

EV

IS

IO

N D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

U

.S .A

R M

Y C

O R

PS

O

FE

N

G

IN

EE

R

S N

EW

Y

O R

K D

IS

TR

IC

T ht tp w w w

.n an

.u sa ce .a rm y.

m il

SHEET

REFERENCE

NUMBER:

DATE:

FILE PATH:

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

F

ED

ER

AL

P

LA

ZA

R O

O M

N

EW

Y

O R

K, N

Y

8-

A N

SI

D

DA

TE

SO

LI

C

IT

A

TI

O N

N O

C O

N

TR

A C

T N

O

FI

LE

N U

M B

ER

FI

LE

N A

M E:

PL

O

T D

A

TE

C K

D B

Y:

D

W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B

M

IT

TE

D

B Y:

PL

O

T

SC

A

LE

SI

ZE

PR

O

JE

CT

S

TA

TU

S:

TH

U

LE

A

IR

B

AS

E

G R

EE

N

LA

N

D

TH

U

LE

C O

N

SO

LI

D

AT

ED

W

2D S-

-B

-0

C:\Users\E3ENDCPP\Documents\ARCH_C2_E3ENDCPP.rvt

3/26/2014 9:27:56 AM

AM

EN

D

M

EN

T

3/

/1

A s in di ca te d

A-132

SE

C

O N

D F

LO

O

R P

LA

N

PA

R T

B

M

AR

C

H

D es ig ne r

A ut ho r

C he ck er

AM

EN

D M

EN

T

N

TRUE NORTH

WIND

PLAN NORTH

0 5,000MM 10,000MM

SCALE 1:100 (MILLIMETERS)

1 : 100A-132A-121

SECOND FLOOR PLAN - PART B1

CHANGES

MADE TO THIS

DRAWING

WERE FOR

7 8654321

D

B

C

A

A-305

7800 7800 7800 9000 9000 7800 7800

MECH

CATWALK

222 A-402

A-213

8.1

C.9

M

AT

C H

LI

N

E

SE

E A-

ROOF BELOWROOF BELOW

OPEN TO BELOW

23.02

5.085.08

MATCHLINE

SEE A-131

AHU-5GA-516

EH-3G

PART C

PART A PART B

GENERAL NOTES:

TOTAL GROSS AREA = 3718.5 SQM

1. REFER TO SHEET G-003 FOR SYMBOLS AND ABBREVIATIONS.

2. REFER TO SHEET A-531 FOR WALL PARTITION TYPES.

3. REFER TO SHEETS A-601 tTHROUGH A-603 FOR DOOR SCHEDULE, DOOR & FRAME TYPES, AND DETAILS.

4. REFER TO SHEET A-604 FOR WINDOW ELEVATIONS AND DETAILS.

5. REFER TO SHEET I-611 FOR ROOM FINISH SCHEDULE.

6. REFER TO CID PACKAGE UNDER A SEPARATE COVER FOR FURNITURE PLACEMENT.

7. ALL EXTERIOR WALLS TO MAINTAIN AN R-VALUE OF R-64.43 ft2·°F·h / (BTU).

8. NONE OF THE BUILDINGS AT THULE AIR BASE ARE REQUIRED TO COMPLY WITH THE US ACCESS BOARD, AMERICANS WITH DISABILITIES ACT GUIDELINES.

9. REFER TO STRUCTURAL DRAWINGS FOR FLOOR SLOPES.

10. REFER TO PART PLANS AT 1:100 FOR KEYNOTES AND DETAILED DIMENSIONS.

11. PROVIDE CONTROL JOINTS IN GYPSUM BOARD AT EVERY 20' OF WALL OR FLOOR IN THE X AND Z DIRECTIONS.

8.41

79MM CORRUGATED METAL ROOFING

INSULATED METAL EXTERIOR OVERHEAD SECTIONAL

DOOR WITH LITES

ARCTIC EXHAUST HOOD

UNIT HEATER. REFER TO MECHANICAL DRAWINGS

KEYNOTES:

23.52

5.08

23.02

US Army Corps of Engineers New York District

SY

M

BO

L

R

EV

IS

IO

N D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

U

.S .A

R M

Y C

O R

PS

O

FE

N

G

IN

EE

R

S N

EW

Y

O R

K D

IS

TR

IC

T ht tp w w w

.n an

.u sa ce .a rm y.

m il

SHEET

REFERENCE

NUMBER:

DATE:

FILE PATH:

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

F

ED

ER

AL

P

LA

ZA

R O

O M

N

EW

Y

O R

K, N

Y

8-

A N

SI

D

DA

TE

SO

LI

C

IT

A

TI

O N

N O

C O

N

TR

A C

T N

O

FI

LE

N U

M B

ER

FI

LE

N A

M E:

PL

O

T D

A

TE

C K

D B

Y:

D

W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B

M

IT

TE

D

B Y:

PL

O

T

SC

A

LE

SI

ZE

PR

O

JE

CT

S

TA

TU

S:

TH

U

LE

A

IR

B

AS

E

G R

EE

N

LA

N

D

TH

U

LE

C O

N

SO

LI

D

AT

ED

W

2D S-

-B

-0

C:\Users\E3ENDCPP\Documents\ARCH_C2_E3ENDCPP.rvt

3/26/2014 9:27:59 AM

AM

EN

D

M

EN

T

3/

/1

A s in di ca te d

A-133

SE

C

O N

D F

LO

O

R P

LA

N

PA

R T

C (O

PT

IO

N

M

AR

C

H

D es ig ne r

A ut ho r

C he ck er

AM

EN

D M

EN

T

1 : 100A-133A-122

SECOND FLOOR PLAN - PART C (OPTION 1)1

N

TRUE NORTH

WIND

PLAN NORTH

0 5,000MM 10,000MM

SCALE 1:100 (MILLIMETERS)

CHANGES

MADE TO THIS

DRAWING

WERE FOR

14131211107 8654321

E

D

F

78410 47290

0 99 / 1000

164 / 1000

A-502

5.08

A-502

8.1

C.9

7800 7800 7800 9000 9000 7800 7800 500 10000 10500 10500 10500 13900 12000

23.02

99 / 1000 99 / 1000

99 / 1000 99 / 1000 99 / 1000 99 / 1000

99 / 1000

164 / 100099 / 1000

23.03 23.02 23.03

23.03 23.02

23.02

A-521

164 / 1000

164 / 1000164 / 1000

KEYNOTES:

79MM CORRUGATED METAL SHEATHING. GRAY: COLOR

TO BE APPROVED BY RESIDENT OFFICE.

ARCTIC EXHAUST HOOD

ARCTIC INTAKE HOOD

5.08

23.02

23.03

US Army Corps of Engineers New York District

SY

M

BO

L

R

EV

IS

IO

N D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

U

.S .A

R M

Y C

O R

PS

O

FE

N

G

IN

EE

R

S N

EW

Y

O R

K D

IS

TR

IC

T ht tp w w w

.n an

.u sa ce .a rm y.

m il

SHEET

REFERENCE

NUMBER:

DATE:

FILE PATH:

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

F

ED

ER

AL

P

LA

ZA

R O

O M

N

EW

Y

O R

K, N

Y

8-

A N

SI

D

DA

TE

SO

LI

C

IT

A

TI

O N

N O

C O

N

TR

A C

T N

O

FI

LE

N U

M B

ER

FI

LE

N A

M E:

PL

O

T D

A

TE

C K

D B

Y:

D

W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B

M

IT

TE

D

B Y:

PL

O

T

SC

A

LE

SI

ZE

PR

O

JE

CT

S

TA

TU

S:

TH

U

LE

A

IR

B

AS

E

G R

EE

N

LA

N

D

TH

U

LE

C O

N

SO

LI

D

AT

ED

W

2D S-

-B

-0

C:\Users\E3ENDCPP\Documents\ARCH_C2_E3ENDCPP.rvt

3/26/2014 9:28:00 AM

AM

EN

D

M

EN

T

3/

/1

A s in di ca te d

A-141

R O

O F

PL

AN

M

AR

C

H

D es ig ne r

A ut ho r

C he ck er

AM

EN

D M

EN

T

1 : 200A-141

ROOF PLAN1

N

TRUE NORTH

WIND

PLAN NORTH

0 10,000MM 20,000MM

D

F

B

C

A

78410 47290

125700

140 / 1000

0 /

99 / 1000 164 / 1000

A-5021

A-503

A-503

5.08

A-502

A-503

8.1

C.9

7800 7800 7800 9000 9000 7800 7800 500 10000 10500 10500 10500 13900 12000

23.03 23.02 23.02

5.08 5.08

23.03

23.03 23.02

5.08

99 / 1000 99 / 1000

99 / 1000

99 / 1000

99 / 1000

A-142

164 / 1000

A-521

KEYNOTES:

79MM CORRUGATED METAL SHEATHING. GRAY: COLOR

TO BE APPROVED BY RESIDENT OFFICE.

ARCTIC EXHAUST HOOD

ARCTIC INTAKE HOOD

5.08

23.02

23.03

A-142

VIF

11.29°

VIF

11.29°

11.29°

CUT

FOLD

FOLD

C U

T C

U T

CUT

C

U T

FO

LD

CONNECTION POINT ACONNECTION

POINT A

BEND SHEET

METAL 90

DEGREES

BEND SHEET

METAL 90

DEGREES

EDGE A ED

G

E B

EDGE A ED

G

E B

EDGE CEDGE C

CUT

FOLD

SHEET METAL TO BE TUCKED

UNDERNEATH ADJACENT LAYER

AND WELDED

SHEET METAL TO BE

REMOVED

3264 2963

US Army Corps of Engineers New York District

SY

M

BO

L

R

EV

IS

IO

N D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

U

.S .A

R M

Y C

O R

PS

O

FE

N

G

IN

EE

R

S N

EW

Y

O R

K D

IS

TR

IC

T ht tp w w w

.n an

.u sa ce .a rm y.

m il

SHEET

REFERENCE

NUMBER:

DATE:

FILE PATH:

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

F

ED

ER

AL

P

LA

ZA

R O

O M

N

EW

Y

O R

K, N

Y

8-

A N

SI

D

DA

TE

SO

LI

C

IT

A

TI

O N

N O

C O

N

TR

A C

T N

O

FI

LE

N U

M B

ER

FI

LE

N A

M E:

PL

O

T D

A

TE

C K

D B

Y:

D

W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B

M

IT

TE

D

B Y:

PL

O

T

SC

A

LE

SI

ZE

PR

O

JE

CT

S

TA

TU

S:

TH

U

LE

A

IR

B

AS

E

G R

EE

N

LA

N

D

TH

U

LE

C O

N

SO

LI

D

AT

ED

W

2D S-

-B

-0

C:\Users\E3ENDCPP\Documents\ARCH_C2_E3ENDCPP.rvt

3/26/2014 9:28:03 AM

AM

EN

D

M

EN

T

3/

/1

A s in di ca te d

A-142

R O

O F

PL

AN

(O

PT

IO

N

M

AR

C

H

D es ig ne r

A ut ho r

C he ck er

AM

EN

D M

EN

T

1 : 200A-142A-201

ROOF PLAN (OPTION 1)1

N

TRUE NORTH

WIND

PLAN NORTH

0 10,000MM 20,000MM

SCALE 1:200 (MILLIMETERS)

1 : 100A-142A-142

SHEET METAL PATTERN OVERLAY2

1 : 50A-142A-142

SHEET METAL PATTERN AT OPTION 1 ROOF PEAK3

D

F

MECH CATWALK ABOVE

MECH CATWALK

ABOVE

D.1

E.1

E.2

1 1

1 15

A-151

2 2 2

2 2

8.1

C.9

OPEN

TO ABOVE

OPEN

TO ABOVE

IH-6G&7GIH-3G

EH-3G

IH-1G&2G EH-1G&2GIH-4G EH-4G

OPEN

TO ABOVE

AHU-6G

11-1

AHU-7G

OPEN

TO ABOVE

OPEN

TO ABOVE

REFLECTED CEILING KEY NOTES

1. ALL CEILING HEIGHTS ARE FROM FINISHED FLR.

2. ALL CEILING FINISHES ARE GYPSUM BOARD U.N.O.

3. ALL CEILING FINISHES IN BATHROOMS WILL BE M.R.GWB.

4. POWER TO EXTERIOR LIGHTS MUST BE CONCEALED. SURFACE

MOUNTED CONDUIT IS NOT PERMITTED.

5. 208 LUX (20 FOOT-CANDLE) REQUIRED FOR CORRIDORS.

6. REF. ELECTRICAL FOR LIGHTING FIXTURE TYPE.

7. REF. SPECIFICATIONS FOR ACCESS PANEL REQUIREMENTS.

REFLECTED CEILING PLAN GENERAL NOTES

CEILING HEIGHT AT 2.59M

CEILING HEIGHT AT 2.74M

CEILING HEIGHT AT 2.82M

CEILING HEIGHT AT 3.75M

EXPOSED STRUCTURE

PERFORATED GYPSUM BOARD

SUSPENDED LED FIXTURES.

SURFACE MOUNTED LED FIXTURES.

REF. EL-501 FOR FIXTURE TYPES.

RECESSED CAN LIGHTING FIXTURE.

REF. EL-501 FOR FIXTURE TYPES.

SUPPLY DIFFUSER

SUPPLY REGISTER

UNIT HEATER

RETURN DUCT

REFLECTED CEILING PLAN LEGEND

E

E.1

E.2

3700 OPEN TO

ABOVE

US Army Corps of Engineers New York District

SY

M

BO

L

R

EV

IS

IO

N D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

U

.S .A

R M

Y C

O R

PS

O

FE

N

G

IN

EE

R

S N

EW

Y

O R

K D

IS

TR

IC

T ht tp w w w

.n an

.u sa ce .a rm y.

m il

SHEET

REFERENCE

NUMBER:

DATE:

FILE PATH:

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

F

ED

ER

AL

P

LA

ZA

R O

O M

N

EW

Y

O R

K, N

Y

8-

A N

SI

D

DA

TE

SO

LI

C

IT

A

TI

O N

N O

C O

N

TR

A C

T N

O

FI

LE

N U

M B

ER

FI

LE

N A

M E:

PL

O

T D

A

TE

C K

D B

Y:

D

W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B

M

IT

TE

D

B Y:

PL

O

T

SC

A

LE

SI

ZE

PR

O

JE

CT

S

TA

TU

S:

TH

U

LE

A

IR

B

AS

E

G R

EE

N

LA

N

D

TH

U

LE

C O

N

SO

LI

D

AT

ED

W

2D S-

-B

-0

C:\Users\E3ENDCPP\Documents\ARCH_C2_E3ENDCPP.rvt

3/26/2014 9:28:07 AM

AM

EN

D

M

EN

T

3/

/1

A s in di ca te d

A-151

FI

R

ST

F

LO

O

R

R

EF

LE

C

TE

D

C

EI

LI

N

G

PL

AN

M

AR

C

H

D es ig ne r

A ut ho r

C he ck er

AM

EN

D M

EN

T

1 : 200A-151A-201

FIRST FLOOR - REFLECTED CEILING PLAN1

N

TRUE NORTH

WIND

PLAN NORTH

0 5,000MM 10,000MM

SCALE 1:100 (MILLIMETERS)

1 : 100A-151A-151

ENLARGED RCP LEVEL 1.52

CHANGES

MADE TO THIS

DRAWING

WERE FOR

D

F

B

C

A

MECH CATWALK

ABOVE

MECH CATWALK

ABOVE

MECH CATWALK

ABOVE

D.1

E.1

E.2

A-151

2 2 2

2 2 2

8.1

C.9

OPEN

1 1 1 1

5 5 5 5 5

IH-6G&7GIH-3G

EH-3G IH-5G

EH-5G

EH-1G&2GIH-1G&2GIH-4G EH-4G

OPEN

TO ABOVE

OPEN

TO ABOVE

OPEN

TO ABOVE

OPEN

TO ABOVE

OPEN

TO ABOVE

OPEN

TO ABOVE

OPEN

TO ABOVE

OPEN

TO ABOVE

OPEN

TO ABOVE

OPEN

TO ABOVE

OPEN

TO ABOVE

REFLECTED CEILING KEY NOTES

1. ALL CEILING HEIGHTS ARE FROM FINISHED FLR.

2. ALL CEILING FINISHES ARE GYPSUM BOARD U.N.O.

3. ALL CEILING FINISHES IN BATHROOMS WILL BE M.R.GWB.

4. POWER TO EXTERIOR LIGHTS MUST BE CONCEALED. SURFACE

MOUNTED CONDUIT IS NOT PERMITTED.

5. 208 LUX (20 FOOT-CANDLE) REQUIRED FOR CORRIDORS.

6. REF. ELECTRICAL FOR LIGHTING FIXTURE TYPE.

7. REF. SPECIFICATIONS FOR ACCESS PANEL REQUIREMENTS.

REFLECTED CEILING PLAN GENERAL NOTES

CEILING HEIGHT AT 2.59M

CEILING HEIGHT AT 2.74M

CEILING HEIGHT AT 2.82M

CEILING HEIGHT AT 3.75M

EXPOSED STRUCTURE

PERFORATED GYPSUM BOARD

SUSPENDED LED FIXTURES.

SURFACE MOUNTED LED FIXTURES.

REF. EL-501 FOR FIXTURE TYPES.

RECESSED CAN LIGHTING FIXTURE.

REF. EL-501 FOR FIXTURE TYPES.

SUPPLY DIFFUSER

SUPPLY REGISTER

UNIT HEATER

RETURN DUCT

REFLECTED CEILING PLAN LEGEND

US Army Corps of Engineers New York District

SY

M

BO

L

R

EV

IS

IO

N D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

U

.S .A

R M

Y C

O R

PS

O

FE

N

G

IN

EE

R

S N

EW

Y

O R

K D

IS

TR

IC

T ht tp w w w

.n an

.u sa ce .a rm y.

m il

SHEET

REFERENCE

NUMBER:

DATE:

FILE PATH:

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

F

ED

ER

AL

P

LA

ZA

R O

O M

N

EW

Y

O R

K, N

Y

8-

A N

SI

D

DA

TE

SO

LI

C

IT

A

TI

O N

N O

C O

N

TR

A C

T N

O

FI

LE

N U

M B

ER

FI

LE

N A

M E:

PL

O

T D

A

TE

C K

D B

Y:

D

W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B

M

IT

TE

D

B Y:

PL

O

T

SC

A

LE

SI

ZE

PR

O

JE

CT

S

TA

TU

S:

TH

U

LE

A

IR

B

AS

E

G R

EE

N

LA

N

D

TH

U

LE

C O

N

SO

LI

D

AT

ED

W

2D S-

-B

-0

C:\Users\E3ENDCPP\Documents\ARCH_C2_E3ENDCPP.rvt

3/26/2014 9:28:19 AM

AM

EN

D

M

EN

T

3/

/1

A s in di ca te d

A-152

FI

R

ST

F

LO

O

R

R

EF

LE

C

TE

D

C

EI

LI

N

G

PL

AN

(O

PT

IO

N

M

AR

C

H

D es ig ne r

A ut ho r

C he ck er

AM

EN

D M

EN

T

1 : 200A-152A-201

FIRST FLOOR - REFLECTED CEILING PLAN (OPTION 1)1

0 10,000MM 20,000MM

SCALE 1:200 (MILLIMETERS)

N

TRUE NORTH

WIND

PLAN NORTH

CHANGES

MADE TO THIS

DRAWING

WERE FOR

D

F

D.1

E.1

E.2

8.1

C.9

OPEN TO

ABOVE

OPEN TO

ABOVEOPEN TO

ABOVE

OPEN TO

ABOVE

OPEN TO

ABOVE

REFLECTED CEILING KEY NOTES

1. ALL CEILING HEIGHTS ARE FROM FINISHED FLR.

2. ALL CEILING FINISHES ARE GYPSUM BOARD U.N.O.

3. ALL CEILING FINISHES IN BATHROOMS WILL BE M.R.GWB.

4. POWER TO EXTERIOR LIGHTS MUST BE CONCEALED. SURFACE

MOUNTED CONDUIT IS NOT PERMITTED.

5. 208 LUX (20 FOOT-CANDLE) REQUIRED FOR CORRIDORS.

6. REF. ELECTRICAL FOR LIGHTING FIXTURE TYPE.

7. REF. SPECIFICATIONS FOR ACCESS PANEL REQUIREMENTS.

REFLECTED CEILING PLAN GENERAL NOTES

CEILING HEIGHT AT 2.59M

CEILING HEIGHT AT 2.74M

CEILING HEIGHT AT 2.82M

CEILING HEIGHT AT 3.75M

EXPOSED STRUCTURE

PERFORATED GYPSUM BOARD

SUSPENDED LED FIXTURES.

SURFACE MOUNTED LED FIXTURES.

REF. EL-501 FOR FIXTURE TYPES.

RECESSED CAN LIGHTING FIXTURE.

REF. EL-501 FOR FIXTURE TYPES.

SUPPLY DIFFUSER

SUPPLY REGISTER

UNIT HEATER

RETURN DUCT

REFLECTED CEILING PLAN LEGEND

US Army Corps of Engineers New York District

SY

M

BO

L

R

EV

IS

IO

N D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

U

.S .A

R M

Y C

O R

PS

O

FE

N

G

IN

EE

R

S N

EW

Y

O R

K D

IS

TR

IC

T ht tp w w w

.n an

.u sa ce .a rm y.

m il

SHEET

REFERENCE

NUMBER:

DATE:

FILE PATH:

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

F

ED

ER

AL

P

LA

ZA

R O

O M

N

EW

Y

O R

K, N

Y

8-

A N

SI

D

DA

TE

SO

LI

C

IT

A

TI

O N

N O

C O

N

TR

A C

T N

O

FI

LE

N U

M B

ER

FI

LE

N A

M E:

PL

O

T D

A

TE

C K

D B

Y:

D

W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B

M

IT

TE

D

B Y:

PL

O

T

SC

A

LE

SI

ZE

PR

O

JE

CT

S

TA

TU

S:

TH

U

LE

A

IR

B

AS

E

G R

EE

N

LA

N

D

TH

U

LE

C O

N

SO

LI

D

AT

ED

W

2D S-

-B

-0

C:\Users\E3ENDCPP\Documents\ARCH_C2_E3ENDCPP.rvt

3/26/2014 9:28:24 AM

AM

EN

D

M

EN

T

3/

/1

A s in di ca te d

A-161

SE

C

O N

D F

LO

O

R

R

EF

LE

C

TE

D

C

EI

LI

N

G

PL

AN

M

AR

C

H

D es ig ne r

A ut ho r

C he ck er

AM

EN

D M

EN

T

1 : 200A-161A-201

SECOND FLOOR - REFLECTED CEILING PLAN1

N

TRUE NORTH

WIND

PLAN NORTH

0 10,000MM 20,000MM

SCALE 1:200 (MILLIMETERS)

CHANGES

MADE TO THIS

DRAWING

WERE FOR

D

F

B

C

A

3 5

WALL BELOW

8.1

C.9

D

D

D

D

D

D

D

OPEN TO

BELOW

OPEN TO

BELOW

OPEN TO

BELOW

OPEN TO

BELOW

OPEN TO

ABOVE

OPEN TO

ABOVE

OPEN TO

ABOVE

OPEN TO

ABOVE

OPEN TO

ABOVE

72653

REFLECTED CEILING KEY NOTES

1. ALL CEILING HEIGHTS ARE FROM FINISHED FLR.

2. ALL CEILING FINISHES ARE GYPSUM BOARD U.N.O.

3. ALL CEILING FINISHES IN BATHROOMS WILL BE M.R.GWB.

4. POWER TO EXTERIOR LIGHTS MUST BE CONCEALED. SURFACE

MOUNTED CONDUIT IS NOT PERMITTED.

5. 208 LUX (20 FOOT-CANDLE) REQUIRED FOR CORRIDORS.

6. REF. ELECTRICAL FOR LIGHTING FIXTURE TYPE.

7. REF. SPECIFICATIONS FOR ACCESS PANEL REQUIREMENTS.

REFLECTED CEILING PLAN GENERAL NOTES

CEILING HEIGHT AT 2.59M

CEILING HEIGHT AT 2.74M

CEILING HEIGHT AT 2.82M

CEILING HEIGHT AT 3.75M

EXPOSED STRUCTURE

PERFORATED GYPSUM BOARD

SUSPENDED LED FIXTURES.

SURFACE MOUNTED LED FIXTURES.

REF. EL-501 FOR FIXTURE TYPES.

RECESSED CAN LIGHTING FIXTURE.

REF. EL-501 FOR FIXTURE TYPES.

SUPPLY DIFFUSER

SUPPLY REGISTER

UNIT HEATER

RETURN DUCT

REFLECTED CEILING PLAN LEGEND

US Army Corps of Engineers New York District

SY

M

BO

L

R

EV

IS

IO

N D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

U

.S .A

R M

Y C

O R

PS

O

FE

N

G

IN

EE

R

S N

EW

Y

O R

K D

IS

TR

IC

T ht tp w w w

.n an

.u sa ce .a rm y.

m il

SHEET

REFERENCE

NUMBER:

DATE:

FILE PATH:

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

F

ED

ER

AL

P

LA

ZA

R O

O M

N

EW

Y

O R

K, N

Y

8-

A N

SI

D

DA

TE

SO

LI

C

IT

A

TI

O N

N O

C O

N

TR

A C

T N

O

FI

LE

N U

M B

ER

FI

LE

N A

M E:

PL

O

T D

A

TE

C K

D B

Y:

D

W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B

M

IT

TE

D

B Y:

PL

O

T

SC

A

LE

SI

ZE

PR

O

JE

CT

S

TA

TU

S:

TH

U

LE

A

IR

B

AS

E

G R

EE

N

LA

N

D

TH

U

LE

C O

N

SO

LI

D

AT

ED

W

2D S-

-B

-0

C:\Users\E3ENDCPP\Documents\ARCH_C2_E3ENDCPP.rvt

3/26/2014 9:28:31 AM

AM

EN

D

M

EN

T

3/

/1

A s in di ca te d

A-162

SE

C

O N

D F

LO

O

R

R

EF

LE

C

TE

D

C

EI

LI

N

G

PL

AN

(O

PT

IO

N

M

AR

C

H

D es ig ne r

A ut ho r

C he ck er

AM

EN

D M

EN

T

1 : 200A-162A-201

SECOND FLOOR - REFLECTED CEILING PLAN (OPTION 1)1

N

TRUE NORTH

WIND

PLAN NORTH

0 10,000MM 20,000MM

SCALE 1:200 (MILLIMETERS)

CHANGES

MADE TO THIS

DRAWING

WERE FOR

FLOOR 1

FLOOR 2

A-211

A-212

14 13 12 11 10 78 6 5 4 3 2 19

99 / 1000

164 / 1000

A-312

A-311

T.O. ROOF 1

17045

B.O. ROOF 1

A-314

M

AT

C H

LI

N

E

SE

E A-

M

AT

C H

LI

N

E

SE

E A-

8.1

99 / 1000 99 / 1000 99 / 1000 99 / 1000164 / 1000 164 / 1000

FLOOR 1

FLOOR 2

14131211107 8654321 9

99 / 1000

164 / 1000

A-214

A-215

A-312

T.O. ROOF 1

17045

B.O. ROOF 1

A-314

M

AT

C H

LI

N

E

SE

E A-

M

AT

C H

LI

N

E

SE

E A-

8.1

99 / 1000 99 / 1000 99 / 1000

THULE BASE COLORS:

EXTERIOR WALL PANELS: GENTIAN BLUE RAL 5010

EXTERIOR PASSENGER DOORS: RASPBERRY RED RAL 3027

ROOFS, WINDOW FRAMES, EXTERIOR OVERHEAD SECTIONAL DOORS: PURE WHITE RAL 9010

MISC COLORS:

FASCIA: STAINLESS STEEL #4 FINISH S.S.

US Army Corps of Engineers New York District

SY

M

BO

L

R

EV

IS

IO

N D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

U

.S .A

R M

Y C

O R

PS

O

FE

N

G

IN

EE

R

S N

EW

Y

O R

K D

IS

TR

IC

T ht tp w w w

.n an

.u sa ce .a rm y.

m il

SHEET

REFERENCE

NUMBER:

DATE:

FILE PATH:

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

F

ED

ER

AL

P

LA

ZA

R O

O M

N

EW

Y

O R

K, N

Y

8-

A N

SI

D

DA

TE

SO

LI

C

IT

A

TI

O N

N O

C O

N

TR

A C

T N

O

FI

LE

N U

M B

ER

FI

LE

N A

M E:

PL

O

T D

A

TE

C K

D B

Y:

D

W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B

M

IT

TE

D

B Y:

PL

O

T

SC

A

LE

SI

ZE

PR

O

JE

CT

S

TA

TU

S:

TH

U

LE

A

IR

B

AS

E

G R

EE

N

LA

N

D

TH

U

LE

C O

N

SO

LI

D

AT

ED

W

2D S-

-B

-0

C:\Users\E3ENDCPP\Documents\ARCH_C2_E3ENDCPP.rvt

3/26/2014 9:29:14 AM

AM

EN

D

M

EN

T

3/

/1

A s in di ca te d

A-201

N O

R

TH

S

O U

TH

EL

EV

AT

IO

N

S

M

AR

C

H

D es ig ne r

A ut ho r

C he ck er

AM

EN

D M

EN

T

1 : 200A-201A-101

NORTH ELEVATION1

1 : 200A-201A-101

SOUTH ELEVATION2

0 10,000MM 20,000MM

FLOOR 2

FLOOR 1.5

14 13 12 11 10 7

6 5 4 3 2 19

A-312

A-311

T.O. ROOF 1

17045

B.O. ROOF 1

T.O. ROOF 2

12550

99 / 1000

140 / 1000 140 / 1000

A-213

A-211

A-314

A-313

8.1

M

AT

C H

LI

N

E

SE

E A-

M

AT

C H

LI

N

E

SE

E A-

164 / 1000

99 / 1000

99 / 1000 99 / 1000

164 / 1000

THULE BASE COLORS:

EXTERIOR WALL PANELS: GENTIAN BLUE RAL 5010

EXTERIOR PASSENGER DOORS: RASPBERRY RED RAL 3027

ROOFS, WINDOW FRAMES, EXTERIOR OVERHEAD SECTIONAL DOORS: PURE WHITE RAL 9010

MISC COLORS:

FASCIA: STAINLESS STEEL #4 FINISH S.S.

US Army Corps of Engineers New York District

SY

M

BO

L

R

EV

IS

IO

N D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

U

.S .A

R M

Y C

O R

PS

O

FE

N

G

IN

EE

R

S N

EW

Y

O R

K D

IS

TR

IC

T ht tp w w w

.n an

.u sa ce .a rm y.

m il

SHEET

REFERENCE

NUMBER:

DATE:

FILE PATH:

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

F

ED

ER

AL

P

LA

ZA

R O

O M

N

EW

Y

O R

K, N

Y

8-

A N

SI

D

DA

TE

SO

LI

C

IT

A

TI

O N

N O

C O

N

TR

A C

T N

O

FI

LE

N U

M B

ER

FI

LE

N A

M E:

PL

O

T D

A

TE

C K

D B

Y:

D

W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B

M

IT

TE

D

B Y:

PL

O

T

SC

A

LE

SI

ZE

PR

O

JE

CT

S

TA

TU

S:

TH

U

LE

A

IR

B

AS

E

G R

EE

N

LA

N

D

TH

U

LE

C O

N

SO

LI

D

AT

ED

W

2D S-

-B

-0

C:\Users\E3ENDCPP\Documents\ARCH_C2_E3ENDCPP.rvt

3/26/2014 9:29:36 AM

AM

EN

D

M

EN

T

3/

/1

A s in di ca te d

A-202

N O

R

TH

E

LE

VA

TI

O N

(O

PT

IO

N

M

AR

C

H

D es ig ne r

A ut ho r

C he ck er

AM

EN

D M

EN

T

1 : 200A-202A-102

NORTH ELEVATION (OPTION 1)1

0 10,000MM 20,000MM

SCALE 1:200 (MILLIMETERS)

CHANGES

MADE TO THIS

DRAWING

WERE FOR

FLOOR 2

FLOOR 1.5

14 13 12 11 10 9

A-312

130N 127N

126N 123N

122N

164 / 1000

T.O. ROOF 1

17045

B.O. ROOF 1

23.04

7.02

7.06

8.02 8.41 23.02

M

AT

C H

LI

N

E

SE

E A-

99 / 1000

7.11

99 / 1000

8.41 8.02 8.028.41 8.41 8.41 TYP.

23.04

26.30

26.33 TYP.23.02

TYP.

164 / 1000

KEYNOTES:

GENERAL NOTE:

1. ALL PENETRATIONS THROUGH THE INSULATED

METAL PANEL MUST BE PERPENDICULAR TO ITS

SURFACE.

79MM CORRUGATED METAL SHEATHING. RAL 5010

GENTIAN BLUE AT EXTERIOR WALLS AND RAL 9010

PURE WHITE AT ROOF.

200MM INSULATED METAL WALL SOFFIT/PANEL WITH

INTERLOCKING EDGES. PANEL EDGE TO HAVE

INDEXED SLOTS WITH CAST-IN ECCENTRIC CAM

LOCKS THAT FASTEN ADJACENT PANELS. RAL 5010:

GENTIAN BLUE.

PRE-FORMED METAL TRIM. RAL 5010: GENTIAN BLUE.

METAL FLASHING TO SERVE AS BOTH FASCIA AND

SOFFIT. PURE WHITE (RAL 9010) TO MATCH

ADJACENT CORRUGATED ROOF PANEL.

INSULATED METAL EXTERIOR DOOR.

INSULATED METAL EXTERIOR OVERHEAD SECTIONAL

DOOR WITH LITES

ARCTIC EXHAUST HOOD

VENT THROUGH ROOF

ELECTRICAL CONDUIT

WALL PACK LIGHTING FIXTURE

5.08

7.02

7.06

7.11

8.02

8.41

23.04

26.30

23.02

26.33

THULE BASE COLORS:

EXTERIOR WALL PANELS: GENTIAN BLUE RAL 5010

EXTERIOR PASSENGER DOORS: RASPBERRY RED RAL 3027

ROOFS, WINDOW FRAMES, EXTERIOR OVERHEAD SECTIONAL DOORS: PURE WHITE RAL 9010

MISC COLORS:

FASCIA: STAINLESS STEEL #4 FINISH S.S.

US Army Corps of Engineers New York District

SY

M

BO

L

R

EV

IS

IO

N D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

U

.S .A

R M

Y C

O R

PS

O

FE

N

G

IN

EE

R

S N

EW

Y

O R

K D

IS

TR

IC

T ht tp w w w

.n an

.u sa ce .a rm y.

m il

SHEET

REFERENCE

NUMBER:

DATE:

FILE PATH:

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

F

ED

ER

AL

P

LA

ZA

R O

O M

N

EW

Y

O R

K, N

Y

8-

A N

SI

D

DA

TE

SO

LI

C

IT

A

TI

O N

N O

C O

N

TR

A C

T N

O

FI

LE

N U

M B

ER

FI

LE

N A

M E:

PL

O

T D

A

TE

C K

D B

Y:

D

W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B

M

IT

TE

D

B Y:

PL

O

T

SC

A

LE

SI

ZE

PR

O

JE

CT

S

TA

TU

S:

TH

U

LE

A

IR

B

AS

E

G R

EE

N

LA

N

D

TH

U

LE

C O

N

SO

LI

D

AT

ED

W

2D S-

-B

-0

C:\Users\E3ENDCPP\Documents\ARCH_C2_E3ENDCPP.rvt

3/26/2014 9:29:37 AM

AM

EN

D

M

EN

T

3/

/1

A s in di ca te d

A-211

N O

R

TH

E

LE

VA

TI

O N

PA

R T

B

M

AR

C

H

D es ig ne r

A ut ho r

C he ck er

AM

EN

D M

EN

T

1 : 100A-211A-111

NORTH ELEVATION - PART B1

0 5,000MM 10,000MM

SCALE 1:100 (MILLIMETERS)

CHANGES

MADE TO THIS

DRAWING

WERE FOR

FLOOR 2

7.02 7.067.11

8.02

78 6 5 4 3 2 1

A-311

T.O. ROOF 1

17045

B.O. ROOF 1

8.41

5.08

M

AT

C H

LI

N

E

SE

E A-

23.02

99 / 1000

A-314

8.1

99 / 1000 99 / 1000 99 / 1000

8.02

111 112 121

120N

23.04

26.33

TYP.

KEYNOTES:

79MM CORRUGATED METAL SHEATHING. RAL 5010

GENTIAN BLUE AT EXTERIOR WALLS AND RAL 9010

PURE WHITE AT ROOF.

200MM INSULATED METAL WALL SOFFIT/PANEL WITH

INTERLOCKING EDGES. PANEL EDGE TO HAVE INDEXED

SLOTS WITH CAST-IN ECCENTRIC CAM LOCKS THAT

FASTEN ADJACENT PANELS. RAL 5010: GENTIAN BLUE.

PRE-FORMED METAL TRIM. RAL 5010: GENTIAN BLUE.

MET…

This is the start of the file's text. The full file is on GovTribe.