Plans_-_Amendment__10.pdf

PDF 1 MB Posted

Attached to
Thule Air Base, Greenland New Building for Vehicle and Equipment Storage
Solicitation number
W912DS-14-B-0007
Issued by

About this file

W912DS-14-B-0007 AMENDMENT 0010 PLANS

View the file

Other files

File Type Posted
FY14_Thule_Consolidation_2_-_Bid_Abstract_-_30_Apr_14_(2).pdf PDF
W912DS-14-B-0007-Amendment_0012_.pdf PDF
W912DS-14-B-0007-Amendment_0011.pdf PDF
W912DS-14-B-0007_AMENDMENT_0010.pdf PDF
Plans_-_Amendment_9.pdf PDF
W912DS-14-B-0007_AMENDMENT_0009.pdf PDF
Plans_-_Amendment_8.pdf PDF
W912DS-14-B-0007_Amendment_0008.pdf PDF
W912DS-14-B-0007-0007.pdf PDF
W912DS-14-B-0007-AMENDMENT_0006.pdf PDF
W912DS-14-B-0007_AMENDMENT_0005.pdf PDF
Plans_-_Amendment__5.pdf PDF
W912DS-14-B-0007_Amendment_0004.pdf PDF
W912DS-14-B-0007_AMENDMENT_0003.pdf PDF
Bid_Schedule_-_Thule_Consolidation_2_-_Amendment__3.pdf PDF
Appendix_T_-_FY14__FY15_Sealift_Rates.pdf PDF
W912DS-14-B-0007-AMENDMENT_0002.pdf PDF
W912DS-14-B-0007-AMENDMENT_0002_Plans.pdf PDF
W912DS-14-B-0007-AMENDMENT_0002_REVISED_BID_SCHEDULE.pdf PDF
W912DS-14-B-0014-AMENDMENT_0001.pdf PDF
Package_1_-_100_Thule_Consolidation_2_-_Plans.pdf PDF
Appendix_U_-_DBA_Waiver.pdf PDF
Appendix_I_-_Slug_Mgmt_Plan.pdf PDF
Appendix_V_-_Project_Site_Survey.dwg DWG drawing
Appendix_J_-_Installation_HAZMAT_Management_Plan.pdf PDF
Appendix_L_-_Affirmative_Proc_Plan.pdf PDF
Package_2_-_100_Thule_Consolidation_2_-_Specifications.pdf PDF
Package_3_-_100_Thule_Consolidation_2_-_SID-CID.pdf PDF
Appendix_D_-_HWM_Plan.pdf PDF
Appendix_M_-_PCB_Replacement_Plan.pdf PDF
Appendix_E_-_Spill_Prevention-Response_Plan.pdf PDF
Appendix_F_-_PPM_Plan.pdf PDF
Appendix_A_-_Active_Landfills.pdf PDF
Appendix_B_-_NFS_Material_Borrow_Site.pdf PDF
Appendix_N_-_Asbestos_Management_Plan.pdf PDF
Appendix_S_-_Pacer_Goose_Shipping_Instructions.pdf PDF
Appendix_P_-_Demo_As-Built_and_Asbestos_Surveys.pdf PDF
Appendix_K_-_FGS-GL_(Environmental_Protection).pdf PDF
Appendix_O_-_Lead_Paint_Management_Plan.pdf PDF
W912DS-14-B-0007_SOLICITATION.pdf PDF
Appendix_C_-_Conservation_Mgmt_Plan.pdf PDF
Appendix_H_-_Storm_Water_Mgmt_Plan.pdf PDF
Appendix_G_-_Solid_Waste_Mgmt_Plan.pdf PDF
Appendix_R_-_Geotechnical_Investigation.pdf PDF
Appendix_Q_-_Shipping_Rates_Gov_Furnished_Transport.pdf PDF
Appendix_T_-_FY14_Sealift_Rates.pdf PDF
Show all 46

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

UP

UP

UP

A-216 2

A-2161

14131211107 8654321

E

D

F

A-301

A-312

A-302

A-311

A-112

FUEL

TRUCK

BAY

AF

VEHICLES

HEAVY

EQUIP

GENERAL

PURPOSE

VEHICLES

RECEPTION

PAINT BAY

BODY

SHOP

400 7800 7800 7800 9000 9000 7800 7800 500 10000 10500 10500 10500 13900 12000 400

125700

P&G

STORAGE

WASH BAY

FIRE

PUMP

ROOM

TIRE

STORAGE

TOOLS &

PARTS

CORRIDOR

WOMEN'S

TOILET

MEN'S

TOILET

MEN'S

TOILET

STORAGE

JANITOR

VEST

VEST

VEST

STAIR

STAIR

VEST

VEST

VEST

VEST

VEST

VEST

VEST

VEST

UTILITY

BAY

A-111

A-201

A-314

D.1

E.1

E.2

A-201

M

AT

C H

LI

N

E

SE

E A-

M

AT

C H

LI

N

E

SE

E A-

8.1

ELEC

PANEL

A-303

A-304

C.9

PART A PART B

GENERAL NOTES:

TOTAL GROSS AREA = 3718.5 SQM

1. REFER TO SHEET G-003 FOR SYMBOLS AND ABBREVIATIONS.

2. REFER TO SHEET A-531 FOR WALL PARTITION TYPES.

3. REFER TO SHEETS A-601 tTHROUGH A-603 FOR DOOR SCHEDULE, DOOR & FRAME TYPES, AND DETAILS.

4. REFER TO SHEET A-604 FOR WINDOW ELEVATIONS AND DETAILS.

5. REFER TO SHEET I-611 FOR ROOM FINISH SCHEDULE.

6. REFER TO CID PACKAGE UNDER A SEPARATE COVER FOR FURNITURE PLACEMENT.

7. ALL EXTERIOR WALLS TO MAINTAIN AN R-VALUE OF R-64.43 ft2·°F·h / (BTU).

8. NONE OF THE BUILDINGS AT THULE AIR BASE ARE REQUIRED TO COMPLY WITH THE US ACCESS BOARD, AMERICANS WITH DISABILITIES ACT GUIDELINES.

9. REFER TO STRUCTURAL DRAWINGS FOR FLOOR SLOPES.

10. REFER TO PART PLANS AT 1:100 FOR KEYNOTES AND DETAILED DIMENSIONS.

11. PROVIDE CONTROL JOINTS IN GYPSUM BOARD AT EVERY 20' OF WALL OR FLOOR IN THE X AND Z DIRECTIONS.

METAL GRATE

MATERIALS LEGEND:

US Army Corps of Engineers New York District

SY

M

BO

L

R

EV

IS

IO

N D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

U

.S .A

R M

Y C

O R

PS

O

FE

N

G

IN

EE

R

S N

EW

Y

O R

K D

IS

TR

IC

T ht tp w w w

.n an

.u sa ce .a rm y.

m il

SHEET

REFERENCE

NUMBER:

DATE:

FILE PATH:

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

F

ED

ER

AL

P

LA

ZA

R O

O M

N

EW

Y

O R

K, N

Y

8-

A N

SI

D

DA

TE

SO

LI

C

IT

A

TI

O N

N O

C O

N

TR

A C

T N

O

FI

LE

N U

M

BE

R:

FI

LE

N A

M E:

PL

O

T D

A

TE

C K

D B

Y:

D

W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B

M

IT

TE

D

B Y:

PL

O

T

SC

A

LE

SI

ZE

PR

O

JE

CT

S

TA

TU

S:

TH

U

LE

A

IR

B

AS

E

G R

EE

N

LA

N

D

TH

U

LE

C O

N

SO

LI

D

AT

ED

W

2D S-

-B

-0

C:\Users\e3endnmw\Documents\REVIT\ARCH_C2_E3ENDNMW.rvt

4/23/2014 11:51:56 AM

AM

EN

D

M

EN

T

4/

/1

A s in di ca te d

A-101

FI

R

ST

F

LO

O

R P

LA

N

A

PR

N M

W

N M

W M

AJ

AM

EN

D M

EN

T

1 : 200A-101A-201

FIRST FLOOR PLAN1

N

TRUE NORTH

WIND

PLAN NORTH

0 10,000MM 20,000MM

SCALE 1:200 (MILLIMETERS)

A

M

EN

D M

EN

T

3/

/1

A M

EN

D

M

EN

4/

/1 e3enmrt3 Text Box

NOTE:

Drawing A-101 has been reissued to show the removal of door 120 from the Car Wash Area. Bidders are instructed that door 120 is to be deleted wherever it appears on the plans/specs including its accessories and exterior lighting.

e3enmrt3 Polygon

T.O. CONC. FL. 1

B.O. FIN. FL. 2

78 6 5 4 3 2 1

5.08

7.02

7.067.11

8.41

99 / 1000

A-311

T.O. ROOF

17045

B.O. ROOF

T.O. ROOF 2

12550

140 / 1000 140 / 1000

M

AT

C H

LI

N

E

SE

E A-

A-314

A-313

5.08

120N

8.1

23.02

7.02 7.11

23.04

VIF11.29°

2963 1

A-503

A-503

KEYNOTES:

79MM CORRUGATED METAL SHEATHING.

200MM INSULATED METAL WALL PANEL WITH

INTERLOCKING EDGES.

PRE-FORMED METAL TRIM TO MATCH ADJACENT PANEL.

PRE-FORMED METAL TRIM. APPLY SEALNT BETWEEN

BETWEEN TRIM AND FACE OF INSULATED METAL PANEL

AND MECHANICALLY FASTEN WITH RIVETS. COLOR TO

MATCH ADJACENT PANEL.

METAL FLASHING.

INSULATED METAL EXTERIOR OVERHEAD SECTIONAL

DOOR WITH LITES

ARCTIC EXHAUST HOOD

VENT THROUGH ROOF

5.08

7.02

7.06

7.11

8.41

23.02

23.04

GENERAL NOTE:

1. PENETRATIONS THROUGH THE INSULATED METAL PANEL

MUST BE THERMALLY BROKEN FROM THE INTERIOR AND

SEALED COMPLETELY AGAINST AIR INFILTRATION.

2.REINFORCE ALL AIR HOODS PROJECTING FROM THE

BUILDING OVER 300MM WITH STRUCTURAL BRACING AND

TENSION WIRES. REFER TO S-001 OF DESIGN LOADS.

CONNECT GUY WIRES TO STRUCTURAL STEEL WITH A

THERMAL BREAK AS PER DETAILS 1 & 2 ON A-521.

THULE BASE COLORS:

EXTERIOR WALL PANELS: GENTIAN BLUE RAL 5010

EXTERIOR PASSENGER DOORS: RASPBERRY RED RAL 3027

ROOFS, WINDOW FRAMES, EXTERIOR OVERHEAD SECTIONAL DOORS: PURE WHITE RAL 9010

MISC COLORS:

FASCIA: STAINLESS STEEL #4 FINISH

US Army Corps of Engineers New York District

SY

M

BO

L

R

EV

IS

IO

N D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

U

.S .A

R M

Y C

O R

PS

O

FE

N

G

IN

EE

R

S N

EW

Y

O R

K D

IS

TR

IC

T ht tp w w w

.n an

.u sa ce .a rm y.

m il

SHEET

REFERENCE

NUMBER:

DATE:

FILE PATH:

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

F

ED

ER

AL

P

LA

ZA

R O

O M

N

EW

Y

O R

K, N

Y

8-

A N

SI

D

DA

TE

SO

LI

C

IT

A

TI

O N

N O

C O

N

TR

A C

T N

O

FI

LE

N U

M

BE

R:

FI

LE

N A

M E:

PL

O

T D

A

TE

C K

D B

Y:

D

W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B

M

IT

TE

D

B Y:

PL

O

T

SC

A

LE

SI

ZE

PR

O

JE

CT

S

TA

TU

S:

TH

U

LE

A

IR

B

AS

E

G R

EE

N

LA

N

D

TH

U

LE

C O

N

SO

LI

D

AT

ED

W

2D S-

-B

-0

C:\Users\e3endnmw\Documents\REVIT\ARCH_C2_E3ENDNMW.rvt

4/23/2014 11:52:29 AM

AM

EN

D

M

EN

T

4/

/1

A s in di ca te d

A-213

N O

R

TH

E

LE

VA

TI

O N

PA

R

T C

(O

PT

IO

N

A

PR

N M

W

N M

W M

AJ

AM

EN

D M

EN

T

1 : 100A-213A-111

NORTH ELEVATION PART C (OPTION 1)1

0 5,000MM 10,000MM

SCALE 1:100 (MILLIMETERS)

A

M

EN

D M

EN

/1

A

M

EN

D M

EN

/1

DC.9

7.06

7.11

7.24

7.08

5.08

7.01

7.16

5.06

5.06

5.06

5.07 5.08

7.06

5.08

7.11

7.02

7.01

7.02

5.09

5.05

7.16

7.16

VIF

11.29°

VIF

11.29°

11.29°

CUT

FOLD

FOLD

C U

T C

U T

CUT

C U

T

FO

LD

CONNECTION POINT ACONNECTION POINT A

BEND SHEET

METAL 90

DEGREES

BEND SHEET

METAL 90

DEGREES

EDGE A ED

G

E B

EDGE A ED

G

E B

EDGE CEDGE C

CUT

FOLD

SHEET METAL TO BE TUCKED

UNDERNEATH ADJACENT LAYER

AND WELDED

SHEET METAL TO BE

REMOVED

3264 2963

A-503

KEYNOTES:

EXPANSION JOINT FILLER

OPEN WEB JOIST RE. STRUCTURAL.

STEEL BEAM. RE: STRUCTURAL.

COLD FORM METAL TRUSSES. RE: STRUCTURAL.

79MM CORRUGATED METAL SHEATHING. RE: COLOR SPECIFICATION FOR FINISH.

225MM INSULATED METAL ROOF PANEL WITH INTERLOCKING EDGE. PANEL EDGE TO HAVE INDEXED SLOTS

WITH CAST-IN ECCENTRI CAM LOCKS THAT FASTEN TO ADJACENT PANELS.

200MM INSULATED METAL WALL PANEL WITH INTERLOCKING EDGE. PANEL EDGE TO HAVE INDEXED SLOTS

WITH CAST-IN ECCENTRI CAM LOCKS THAT FASTEN TO ADJACENT PANELS.

PRE-FORMED METAL TRIM. APPLY SEALNT BETWEEN BETWEEN TRIM AND FACE OF INSULATED METAL PANEL

AND MECHANICALLY FASTEN WITH RIVETS. COLOR TO MATCH ADJACENT PANEL.

POLYETHYLENE END CLOSURE.

METAL FLASHING.

METAL FLASHING TO RUN CONTINUOUSLY ALONG THE INSIDE FACE OF THE METAL INSULATED PANELS AT ALL

JOINTS AND BREAKS. FLASHING TO BE MECHANICALLY FASTENED TO PANELS.

EXPANSION JOINT

5.06

5.07

5.08

3.20

5.01

7.01

7.02

7.06

7.11

7.16

7.24

7.08

99/1000

0/

140/1000

EDGE C

EDGE AEDGE B

CONNECTION POINT A

7.06 5.08

5.06

7.16

7.06

7.11

7.11

7.08

5.08

US Army Corps of Engineers New York District

SY

M

BO

L

R

EV

IS

IO

N D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

U

.S .A

R M

Y C

O R

PS

O

FE

N

G

IN

EE

R

S N

EW

Y

O R

K D

IS

TR

IC

T ht tp w w w

.n an

.u sa ce .a rm y.

m il

SHEET

REFERENCE

NUMBER:

DATE:

FILE PATH:

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

F

ED

ER

AL

P

LA

ZA

R O

O M

N

EW

Y

O R

K, N

Y

8-

A N

SI

D

DA

TE

SO

LI

C

IT

A

TI

O N

N O

C O

N

TR

A C

T N

O

FI

LE

N U

M

BE

R:

FI

LE

N A

M E:

PL

O

T D

A

TE

C K

D B

Y:

D

W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B

M

IT

TE

D

B Y:

PL

O

T

SC

A

LE

SI

ZE

PR

O

JE

CT

S

TA

TU

S:

TH

U

LE

A

IR

B

AS

E

G R

EE

N

LA

N

D

TH

U

LE

C O

N

SO

LI

D

AT

ED

W

2D S-

-B

-0

C:\Users\e3endnmw\Documents\REVIT\ARCH_C2_E3ENDNMW.rvt

4/23/2014 11:44:53 AM

AM

EN

D

M

EN

T

4/

/1

A s in di ca te d

A-503

W

AL

L

SE

C

TI

O N

S

R O

O F

D

ET

AI

LS

(O

PT

IO

N

1)

A

PR

N M

W

N M

W M

AJ

AM

EN

D M

EN

T

1 : 10A-503A-213

DETAIL @ CONNECTION TO OPTION 11

1 : 20A-503A-142

SECTION AT AWNING (OPTION 1)3

0 1,000MM 2,000MM

SCALE 1:20 (MILLIMETERS)

1 : 50A-503A-503

ROOF FLASHING - SHEET METAL PATTERN (OPTION 1)2

1 : 100A-503A-142

PATTERN RELATIVE TO ROOF JUNCTION AT PEAK (OPTION 1)4

NTSA-503

ISOMETRIC OF ASSEMBLED ROOF FLASHING5

0 5,000MM 10,000MM

SCALE 1:100 (MILLIMETERS)

0 1,250MM 2,500MM

SCALE 1:50 (MILLIMETERS)

A

M

EN

D M

EN

/1

1 : 20A-503A-212

DETAIL @ WALL/ROOF CONNECTION (OPT 1)6

A

M

EN

D M

EN

/1