Attachment 1 _SALIENT_CHARACTERISTICS -29 July.xlsx

XLSX spreadsheet 13 KB Posted

Attached to
DFAC Lockers with Benches
Solicitation number
W912CM26QA021
Issued by

About this file

This is a specifications attachment detailing salient characteristics for a Firm-Fixed-Price solicitation (W912CM26QA021) issued by the Department of the Army Materiel Command Army Contracting Command, Regional Contracting Office - Wiesbaden, for locker room equipment and painting services at a U.S. Government facility in Germany. The requirement includes six line items: 54 Clean/Dirty Separation Lockers (brand name or equal to C+P "Classic PLUS" with separate internal compartments for street clothes and work/PPE clothing, heavy-duty steel construction, soft-stop hinged doors, padlock-compatible latches, ventilation louvers, Light Grey body with Architectural Blue doors, and 2-year warranty); 6 Solid Benches (freestanding, square steel tubing construction with hardwood slats, clear-varnished finish, and 2-year warranty); 6 Coat Rack Extensions (freestanding backrest and coat rail with square steel tubing, hardwood slats, and minimum four double hooks meeting DIN 7917 safety standards, 2-year warranty); interior wall painting of two locker rooms covering 210 square meters (including primer and finish coats, mobile scaffolding supply and dismantling, plaster repair, masking and coverings, using StoColor system color code 37206); interior ceiling painting of approximately 54 square meters of aluminum ceiling (standard commercial-grade white latex paint, color code 9016 with silky shine finish); and dismantling and reinstallation of locker units (including all labor, materials, professional removal, safe installation anchored per manufacturer guidelines, and work area cleanup). All work must be performed on-site within Germany, with site visit held on 23 July 2026 at 9:00 AM CET and solicitation closing on 11 August 2026 at 15:00 PM CET. Offerors must be registered in the System for Award Management (SAM) database and demonstrate capability to perform all required work within Germany.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1

Locker Room Lockers and Wall Painting
LocationItem #Brief DescriptionDescriptionQtyVoltageHertzWattsPhaseNominal CapacityWarrantyExterior Dimensions
Wiesbaden1LockerClean/Dirty Separation Lockers (Brand Name or Equal to C+P "Classic PLUS" PSA Schwarz-Weiß-Spind). Must provide separate internal compartments for the hygienic separation of street clothes ("white") and work/PPE clothing ("black"). Heavy-duty steel body and doors. Must include protective feet or a raised base (approximately 100 mm) to protect against floor moisture. Hinged steel doors equipped with a noise-dampening or "soft-stop" mechanism. Padlock-compatible rotary latch or ergonomic safety twist-lock mechanism. Must include adequate ventilation (e.g., louvers or perforation patterns in doors or body). Body in Light Grey (RAL 7035 or equivalent standard industrial grey) and doors in Architectural Blue (RAL 2406015 or equivalent standard industrial blue). With 2 year warranty.54N/AN/AN/AN/A2 YearH x W x D:1900 - 2000 x 600 x 500mm (76.77 - 86.77" x 23.62" x 19.68")
Wiesbaden2Solid BenchFreestanding Locker Room Bench. Sturdy square steel tubing (approximately 30 x 30 mm), powder-coated or painted for corrosion resistance. Hardwood slats (e.g., Beech or equal), planed, sanded, and clear-varnished for a smooth, splinter-free finish. With 2 year warranty.6N/AN/AN/AN/A2 YearHxWxD: 450mm x 1000mm x 350 - 360mm (17.71" x 39.37" x 14.10 - 15.10")
Wiesbaden3Coat Rack ExtensionFreestanding Backrest and Coat Rail. Same construction requirements as Item 2 (square steel tubing and clear-varnished hardwood slats). Hardwood slats matching the seating surface. Integrated overhead rail equipped with a minimum of four (4) double hooks. Hooks must feature a concealed or rounded-edge design for safety (meeting the functional equivalent of DIN 7917 safety standards to prevent injury). With 2 year warranty.6N/AN/AN/AN/A2 yearH x W x D: 1600 - 1700 mm x 1000 mm x 110 mm (67.55" x 39.37" x 4.33")
Wiesbaden4Wall PaintingInterior painting of two seperate locker rooms, to include primer and finish coats. Supply, assemble and dismantle of a mobile Scaffolding. Repair of damaged plaster surfaces and filling of cracks. All area will have masking and coverings to prevent damage to non panted surfaces. Standard commercial-grade latex interior paint (color and finish to be specified at award or via site visit). The wall paint color code for the rooms is 37206 using the StoColor system.N/AN/AN/AN/A210 Square Meter
Wiesbaden5Interior Ceiling PaintingProfessional preparation and painting of approximately 54 square meters of interior aluminum ceiling. Must include standard site prep, including masking off fixtures, surface cleaning and prepping prior to application. Standard commercial-grade latex interior white paint. Ceiling paint with color code 9016 with silky shine (“Seidenglänzend”) finish.N/AN/AN/AN/AApproximately 54 square meters
Wiesbaden6Dismantling and Reinstallation of LockerThe contractor shall provide all labor and materials necessary for professional dismantling, safe removal, and subsequent installation of locker units, with the understanding that the existing lockers being removed cover the exact footprint and location where the new locker units are to be installed. The government will provide a trash container for the disposal of the dismantled units and associated debris. The government will coordinate the pick-up and disposal of the trash container. The service includes the professional installation of new lockers (as specified in Item 1) ensuring they are plumb, level, and securely anchored to the wall and/or floor per manufacturer guidelines. Upon completion, the contractor must remove all tools, equipment, packaging materials, and installation-related debris to leave the work area in a clean and orderly condition.N/AN/AN/AN/A

File details come from the government source that posted it. Updated .