This document outlines the salient characteristics and specifications for a federal contract opportunity involving locker room renovation and furnishing services. The scope includes six primary deliverables: procurement of clean/dirty separation lockers (Item 1) equivalent to the C+P "Classic PLUS" PSA model with separate internal compartments for street clothes and work/PPE clothing, measuring approximately 1900-2000 mm height × 600 mm width × 500 mm depth, featuring heavy-duty steel construction, noise-dampening hinged doors, and color specifications of light grey (RAL 7035) body with architectural blue (RAL 2406015) doors, all with a 2-year warranty; freestanding locker room benches (Item 2) approximately 450 mm height × 1000 mm width × 350-360 mm depth with square steel tubing and hardwood slats; and freestanding backrest and coat rail units (Item 3) approximately 1000 mm length with 1600-1700 mm overall height, featuring integrated overhead rails with minimum four double hooks meeting DIN 7917 safety standards.
The remaining deliverables consist of professional interior painting services covering approximately 210 square meters of wall space (Item 4) using StoColor system color code 37206, and ceiling painting services for approximately 110 square meters of aluminum ceiling (Item 5) with color code 9016 in silky finish. Item 6 requires complete dismantling and reinstallation of locker units, including professional preparation, plumb and level installation with secure anchoring per manufacturer guidelines, and removal of all debris. All work, including dismantling, reinstallation, and associated painting services, must be fully completed within fourteen (14) workdays with close coordination with the facility point of contact to minimize operational disruption. The government will provide trash containers and coordinate disposal of dismantled units.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Salient Characteristics
Item 1: Clean/Dirty Separation Lockers (Brand Name or Equal to C+P "Classic PLUS" PSA Schwarz-Weiß-Spind). Must provide separate internal compartments for the hygienic separation of street clothes ("white") and work/PPE clothing ("black").
Approximately 1900 mm to 2000 mm (Height) x 600 mm (Width) x 500 mm (Depth).
Heavy-duty steel body and doors. Must include protective feet or a raised base (approximately 100 mm) to protect against floor moisture. Hinged steel doors equipped with a noise-dampening or "soft-stop" mechanism. Padlock-compatible rotary latch or ergonomic safety twist-lock mechanism. Must include adequate ventilation (e.g., louvers or perforation patterns in doors or body). Body in Light Grey (RAL 7035 or equivalent standard industrial grey) and doors in Architectural Blue (RAL 2406015 or equivalent standard industrial blue). With 2-year warranty.
Item 2: Freestanding Locker Room Bench. Approximately 450 mm (Height) x 1000 mm (Width) x 350 mm to 360 mm (Depth). Sturdy square steel tubing (approximately 30 x 30 mm), powder-coated or painted for corrosion resistance. Hardwood slats (e.g., Beech or equal), planned, sanded, and clear-varnished for a smooth, splinter-free finish.
With 2-year warranty.
Item 3: Freestanding Backrest and Coat Rail. Length of approximately 1000 mm, seat height of approximately 450 mm, and overall height accommodating a coat rail (typically 1600 mm to 1700 mm). Same construction requirements as Item 2 (square steel tubing and clear-varnished hardwood slats). Hardwood slats matching the seating surface.
Integrated overhead rail equipped with a minimum of four (4) double hooks. Hooks must feature a concealed or round-edge design for safety (meeting the functional equivalent of DIN 7917 safety standards to prevent injury). With 2-year warranty.
Item 4: Interior Painting Services. Professional preparation and painting of approximately 210 square meters of interior wall space. Must include standard site prep, including masking off fixtures/floors, minor plaster repair, and surface smoothing prior to application. Standard commercial-grade latex interior paint (color and finish to be specified at award or via site visit). The wall paint color code for the rooms is 37206 using the StoColor system.
Item 5: Interior Ceiling Painting Services. Professional preparation and painting of approximately 110 square meters of interior aluminum ceiling (~55 square meters per room). Must include standard site prep, including masking off fixtures, surface cleaning and prepping prior to application. Standard commercial-grade latex interior white paint.
Ceiling paint with color code 9016 with silky shine (“Seidenglänzend”) finish.
Item 6: Dismantling and Reinstallation of Locker. The contractor shall provide all labor and materials necessary for professional dismantling, safe removal, and subsequent installation of locker units, with the understanding that the existing lockers being removed cover the exact footprint and location where the new locker units are to be installed. The government will provide a trash container for the disposal of the dismantled units and associated debris. The government will coordinate the pick-up and disposal of the trash container. The service includes the professional installation of new lockers (as specified in Item 1) ensuring they are plumb, level, and securely anchored to the wall and/or floor per manufacturer guidelines. Upon completion, the contractor must remove all tools, equipment, packaging materials, and installation-related debris to leave the work area in a clean and orderly condition.
All work, including the dismantling and reinstallation of lockers as well as the associated interior painting services (Item 4 and 5) for this space, must be fully completed and finalized within fourteen (14) workdays, with all operations closely coordinated with the facility point of contact to minimize operational disruption.
File details come from the government source that posted it. Updated .