THIRD-SchedulePrices_W912C320B0001_RoofRepairs_20200306.xlsx

XLSX spreadsheet 40 KB Posted

Attached to
Roof Inspection, Repairs and Maintenance at Fort Buchanan, Puerto Rico.
Solicitation number
W912C320B0001
Issued by

View the file

Other files

File Type Posted
BidAbstract_W912C320B0001_RoofRepairs_20200514.pdf PDF
Amend0007_W912C320B0001_RoofRepairs20200506.pdf PDF
Amend0006_W912C320B0001_RoofRepairs20200428.pdf PDF
Amend0005_W912C320B0001_RoofRepairs20200421.pdf PDF
Amend0004_W912C320B0001_RoofRepairs20200409.pdf PDF
Amend0003_W912C320B0001_RoofRepairs20200318.pdf PDF
Photo12Amend0002_W912C320B0001_RoofRepairs20200316.pdf PDF
Amend0002_W912C320B0001_RoofRepairs20200316.pdf PDF
Photo2Amend0002_W912C320B0001_RoofRepairs20200316.pdf PDF
Photo9Amend0002_W912C320B0001_RoofRepairs20200316.pdf PDF
Photo3Amend0002_W912C320B0001_RoofRepairs20200316.pdf PDF
Photo8Amend0002_W912C320B0001_RoofRepairs20200316.pdf PDF
Photo11Amend0002_W912C320B0001_RoofRepairs20200316.pdf PDF
Photo4Amend0002_W912C320B0001_RoofRepairs20200316.pdf PDF
Photo7Amend0002_W912C320B0001_RoofRepairs20200316.pdf PDF
Photo10Amend0002_W912C320B0001_RoofRepairs20200316.pdf PDF
Photo5Amend0002_W912C320B0001_RoofRepairs20200316.pdf PDF
Photo1Amend0002_W912C320B0001_RoofRepairs20200316.pdf PDF
Photo6Amend0002_W912C320B0001_RoofRepairs20200316.pdf PDF
Amend0001_W912C320B0001_RoofRepairs20200309.pdf PDF
FIRST-SchedulePrices_W912C320B0001_RoofRepairs_20200306.xlsx XLSX spreadsheet
BASE-SchedulePrices_W912C320B0001_RoofRepairs_20200306.xlsx XLSX spreadsheet
FOURTH-SchedulePrices_W912C320B0001_RoofRepairs_20200306.xlsx XLSX spreadsheet
Solicitation-W912C320B0001-RoofRepair-20200306.pdf PDF
SECOND-SchedulePrices_W912C320B0001_RoofRepairs_20200306.xlsx XLSX spreadsheet
Dwg_W912C320B0001-RoofRepair-20200306.pdf PDF
SOWSpecs_W912C320B0001-RoofRepairs-20200306.pdf PDF
Show all 27

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

THIRD OPTION

SCHEDULE OF PRICES
THIRD OPTION PERIOD: IFB W912C320B0001, ROOF REPAIR INSPECTION & MAINTENANCE
ItemItem DescriptionEstimatedUnitUnit CostTotal Cost
Quantity
3001Roof Inspection Survey and Written Report with As-Built Roof Plan125,000SF
(Section 01 11 00, Para 1.2, 1.2.1, 1.2.2.a through h)

3002 Provide As-Built Roof Plans (Section 01 11 00, Para 1.2.2) 125,000 SF

3003Sampling & Laboratory Testing and Test Report for Asbestos Materials15EA
(Section 01 11 00, Para 1.2.2.e and Para 1.4.6)
3004Repair Concrete Roof (Plain Concrete)1,500SF
(Section 01 11 00, Para 1.4.1.a, b, c, d, e) (See Tech Specs.)
3005Repair Corrugated Metal Roof5,000SF
(Section 01 11 00, Para 1.4.2.a, b, c) (See Tech Specs.)
3006Remove and Dispose Corrugated Metal Roof Panels, GA 24520SF
(Section 01 11 00, Para 1.4.2.e) (See Tech Specs.)
3007Install Corrugated Metal Roof Panels, GA 24520SF
(Section 01 11 00, Para 1.4.2.e) (See Tech Specs.)
3008Remove and Dispose Corrugated Metal Roof Panels, GA 26520SF
(Section 01 11 00, Para 1.4.2.e) (See Tech Specs.)
3009Install Corrugated Metal Roof Panels, GA 26520SF
(Section 01 11 00, Para 1.4.2.e) (See Tech Specs.)
3010Repair Corrugated Metal Roof: Painting5,000SF
(Section 01 11 00, Para 1.4.2. d, f, and g)
3011Repair Modified Bitumen (Insulation, and 3-ply w/cold adhesvie)200SF
(See Tech Specs.)
3012Repair Modified Bitumen (Insulation, and 3-ply w/torched seams)200SF
(See Tech Specs.)
3013Repair Modified Bitumen (Insulation, and 2-ply w/cold200SF
adhesive or torched seams) (See Tech Specs.)
3014Repair Light weight Concrete insulation, Lt weight880SF
cellular roof fill, Port & Cem. 2 inch thick average and foaming agent
(See Tech Specs.)
3015Remove and Dispose Light weight Concrete insulation, Lt weight880SF
cellular roof fill, Port & Cem. 2 inch thick average and foaming agent
(See Tech Specs.)
3016Install Light weight Concrete insulation, Lt weight cellular roof fill, Port &880SF
Cem. 2 inch thick average and foaming agent (See Tech Specs.)
3017Repair Light weight Concrete insulation, Lt weight cellular roof fill, Port &880SF
Cem. 4 inch thick average and foaming agent (See Tech Specs.)
3018Remove and Dispose Light weight Concrete insulation, Lt weight880SF
cellular roof fill, Port & Cem. 4 inch thick average and foaming agent
(See Tech Specs.)
3019Install Light weight Concrete insulation, Lt weight cellular roof fill, Port &880SF
Cem. 4 inch thick average and foaming agent (See Tech Specs.)
3020Remove and Dispose Insulation 2-inch Average Thick1,500SF
(See Tech Specs.)

3021 Install Insulation 2-inch Average Thick (See Tech Specs.) 1,500 SF

3022 Remove and Dispose E.P.D.M with Insulation (See Tech Specs.) 2,000 SF

3023 Install E.P.D.M with Insulation (See Tech Specs.) 2,000 SF

3024 Remove and Dispose Built-up Roofing (Insulation 3-ply, Hot Adhesive and Gravel) (See Tech Specs.) 8,000 SF

3025Install Built-up Roofing (Insulation 3-ply, Hot Adhesive and Gravel)8,000SF
(See Tech Specs.)
3026Repair Single Ply with adhesive or Asphalt Moppping1,040SF
(See Tech Specs.)

3027 Repair Insulation and Hot Asphalt Plies 520 SF

3028Remove and Dispose Standing Seam Metal Over Insulation260SF
(Section 07 61 13)
3029Install Standing Seam Metal Over Insulation260SF
(Section 07 61 13)
3030Remove and Dispose Asphalt Shingles over Insulation and over100SF
standing Seam Metal Roof (See Tech Specs.)
3031Install Asphalt Shingles over Insulation and over100SF
standing Seam Metal Roof (See Tech Specs.)
3032Repair Water Proof Asphalt Coating200SF
(See Tech Specs.)
3033Repair Sprayed Polyurethane with top Silicone Coating (PUF)5,000SF
(See Tech Specs.)
3034Remove and Dispose Primer and Elastomeric Coating5,000SF
(See Tech Specs.)

3035 Install Primer and Elastomeric Coating (See Tech Specs.) 5,000 SF

3036Blisters Repairs for Modified Bitumen260SF
(Section 01 11 00, Para 1.4.3) (See Tech Specs.)
3037Blister Repairs for E.P.D.M.520SF
(Section 01 11 00, Para 1.4.3) (See Tech Specs.)
3038Blister Repairs for Built-up Roofing1,040SF
(Section 01 11 00, Para 1.4.3) (See Tech Specs.)
3039Blister Repairs for PUF520SF
(Section 01 11 00, Para 1.4.5.d and e.(1) through (8) (See Tech Specs.)
3040PUF Minor Repairs260SF
(Section 01 11 00 , Para 1.4.5.C.(1) through (5) (See Tech Specs.)
3041PUF or Built-up Roofing Repairs w/Asbestos Mastic (ACM)260SF
(Section 01 11 00, Para 1.4.6) (See Tech Specs.)
3042PUF or Built-up Roofing Replacement w/Asbestos Mastic (ACM)5,200SF
(Section 01 11 00, Para 1.4.6) (See Tech Specs.)
3043Remove and Dispose Radiant Barrier Blanket130,000SF
Section 01 11 00, Para 1.5, 1.5.1 and 1.5.2) (See Tech Specs.)
3044Install Radiant Barrier Blanket130,000SF
Section 01 11 00, Para 1.5, 1.5.1 and 1.5.2) (See Tech Specs.)
3045Repair Cracks at Roofing Systems1,040LF
(Section 01 11 00, Para 1.4.3.e) (See Tech Specs.)
3046Correct Water Ponding Areas at Roofing Systems1,040SF
(Section 01 11 00, Para 1.4.3.d) (See Tech Specs.)
3047Maintenance for Roofing Systems130,000SF
(Section 01 11 00, Par1.9.a through c) (See Tech Specs.)
3048Cement parging, 2 coats, waterproofed Portland cement (See Tech1,040SF
Specs.)
3049Structural steel projects, steel surface treatments, wire brush, hand520SF
sanding (See Tech Specs.)
3050Struct. steel projects,sprayed painting,univ primer plus1 paint coat,520SF
phenolic, modified alkyd (See Tech Specs.)
3051Near white blast, (SSPC-10), exist coat blistered/pitted,520SF
9.0 #/SF (See Tech Specs.)
3052Structural steel project,pnts&prot ctg,sprayed,zinc rich primer,epoxy,520SF
spray,organic (See Tech Specs.)

3053 Strl st projs, pnts & prot ctg, sprayed, epoxy, intmd or topcoat (See Tech Specs.) 520 SF

3054Epoxy dk ctg, bitumen modified polyurethane, fld applied,520SF
55 mils thk (See Tech Specs.)

3055 Remove and Dispose Open web joist girders, average (See Tech Specs.) 1 TON

3056 Install Open web joist girders, average (See Tech Specs.) 1 TON

3057 Remove and Dispose Lightweight framing, angle, field fab, 3" x 3" x 3/8" (See Tech Specs.) 45 LF

3058Install Lightweight framing, angle, field fab, 3" x 3" x 3/8" (See Tech45LF
Specs.)

3059 Remove and Dispose Framing, joists, 2" x 12" (See Tech Specs.) 55 LF

3060 Install Framing, joists, 2" x 12" (See Tech Specs.) 55 LF

3061 Remove and Dispose Framing, joists, 2" x 4" (See Tech Specs.) 55 LF

3062 Install Framing, joists, 2" x 4" (See Tech Specs.) 55 LF

3063 Remove and Dispose Framing, joists, 2" x 6" (See Tech Specs.) 55 LF

3064 Install Framing, joists, 2" x 6" (See Tech Specs.) 55 LF

3065 Remove and Dispose Framing, joists, 2" x 8" (See Tech Specs.) 55 LF

3066 Install Framing, joists, 2" x 8" (See Tech Specs.) 55 LF

3067 Remove and Dispose Framing, joists, 2" x 10" (See Tech Specs.) 55 LF

3068 Install Framing, joists, 2" x 10" (See Tech Specs.) 55 LF

3069 Remove and Dispose Framing, roofs, fascia boards, 2" x 8" (See Tech Specs.) 55 LF

3070 Install Framing, roofs, fascia boards, 2" x 8" (See Tech Specs.) 55 LF

3071 Remove and Dispose Framing, roofs, rafters, to 4 in 12 pitch, 2" x 8" (See Tech Specs.) 55 LF

3072 Install Framing, roofs, rafters, to 4 in 12 pitch, 2" x 8" (See Tech Specs.) 55 LF

3073 Remove and Dispose Framing, roofs, rafters, to 4 in 12 pitch, 2" x 6" (See Tech Specs.) 55 LF

3074 Install Framing, roofs, rafters, to 4 in 12 pitch, 2" x 6" (See Tech Specs.) 55 LF

3075 Remove and Dispose Framing, roofs, ridge board, #2 or better, 1" x 8" (See Tech Specs.) 55 LF

3076 Install Framing, roofs, ridge board, #2 or better, 1" x 8" (See Tech Specs.) 55 LF

3077 Remove and Dispose Framing, roofs, roof cants, split, 4" x 4" (See Tech Specs.) 55 LF

3078 Install Framing, roofs, roof cants, split, 4" x 4" (See Tech Specs.) 55 LF

3079 Remove and Dispose Framing, miscellaneous, nailers, treated, wood construction, 2" x 6" (See Tech Specs.) 55 LF

3080Install Framing, miscellaneous, nailers, treated, wood construction,55LF
2" x 6" (See Tech Specs.)

3081 Remove and Dispose Exp jt,butyl or nprn ctr W/foam insul,alum,.032"thk for opng to 2-1/2" (See Tech Specs.) 104 LF

3082Install Exp jt,butyl or nprn ctr W/foam insul,alum,.032"thk for opng to104LF
2-1/2" (See Tech Specs.)

3083 Remove and Dispose Exp jt, butyl or nprn ctr W/foam insul, alum, for jt opngs to 3-1/2" (See Tech Specs.) 104 LF

3084Install Exp jt, butyl or nprn ctr W/foam insul, alum, for jt opngs to104LF
3-1/2" (See Tech Specs.)

3085 Remove and Dispose Expansion joint, roof joint with extruded aluminum cover, 2" (See Tech Specs.) 55 LF

3086 Install Expansion joint, roof joint with extruded aluminum cover, 2" (See Tech Specs.) 55 LF

3087 Remove and Dispose Expansion joint, roof to wall joint with extruded aluminum cover (See Tech Specs.) 55 LF

3088Install Expansion joint, roof to wall joint with extruded aluminum cover55LF
(See Tech Specs.)
3089Remove and Dispose Expansion joint, wall joint, closed cell foam on PVC55LF
cover, 9" wide (See Tech Specs.)
3090Remove and Dispose Expansion joint, wall joint, closed cell foam on PVC55LF
cover, 9" wide (See Tech Specs.)

3091 Remove and Dispose Expansion jt, neoprene, dbl-seal type with thick center, 4-1/2" wide (See Tech Specs.) 55 LF

3092Install Expansion jt, neoprene, dbl-seal type with thick center,55LF
4-1/2" wide (See Tech Specs.)

3093 Cleaning high pressure water only, minimum (See Tech Specs.) 130,000 SF

3094 Remove and Dispose Sheathing, with boards, 1" x 12" boards, laid diagonal (See Tech Specs.) 55 SF

3095 Install Sheathing, with boards, 1" x 12" boards, laid diagonal (See Tech Specs.) 55 SF

3096 Remove and Dispose Sheathing, plywood on roof, CDX, 5/8" thick (See Tech Specs.) 55 SF

3097 Install Sheathing, plywood on roof, CDX, 5/8" thick (See Tech Specs.) 55 SF

3098 Remove and Dispose Steel roofing, on steel frame, corrugated or ribbed, galv, 24 ga (See Tech Specs.) 55 SF

3099Install Steel roofing, on steel frame, corrugated or ribbed, galv, 24 ga55SF
(See Tech Specs.)
3100Remove and Dispose Steel roofing, on steel frame, corrugated or ribbed, galv, 26 ga55SF
(See Tech Specs.)
3101Install Steel roofing, on steel frame, corrugated or ribbed, galv, 26 ga55SF
(See Tech Specs.)

3102 Remove and Dispose roof flat profile, 1-3/4" stand. seams, 12" w, stand. fin. 24 ga. (See Tech Specs.) 55 SF

3103Install Steel roof flat profile, 1-3/4" stand. seams, 12" w, stand. fin. 24 ga.55SF
(See Tech Specs.)

3104 Remove and Dispose Aluminum roofing, corrugated, painted, .032" thick (See Tech Specs.) 55 SF

3105Install Aluminum roofing, corrugated, painted, .032" thick (See Tech55SF
Specs.)

3106 Remove and Dispose Asphalt shingles, #15 felt underlayment (See Tech Specs.) 55 SF

3107 Install Asphalt shingles, #15 felt underlayment (See Tech Specs.) 55 SF

3108 Remove and Dispose Asphalt shingles, std strip shingles, inorganic, class A, 210-235 lb/sq (See Tech Specs.) 55 SF

3109Install Asphalt shingles, std strip shingles, inorganic, class A,55SF
210-235 lb/sq (See Tech Specs.)

3110 Remove and Dispose Steel roofing, ridge, galvanized, 20" wide (See Tech Specs.) 55 LF

3111 Install Steel roofing, ridge, galvanized, 20" wide (See Tech Specs.) 55 LF

3112 Remove and Dispose Fascia, aluminum, .032" thick, colored, NO furring included (See Tech Specs.) 55 SF

3113Install Fascia, aluminum, .032" thick, colored, NO furring included55SF
(See Tech Specs.)
3114Remove and Dispose Fascia, steel, galv and enameled, stock, NO furring,55SF
long panels (See Tech Specs.)
3115Install Fascia, steel, galv and enameled, stock, NO furring,55SF
long panels (See Tech Specs.)

3116 Remove and Dispose Gutters, aluminum, 5" box type, enameled (See Tech Specs.) 160 LF

3117 Install Gutters, aluminum, 5" box type, enameled (See Tech Specs.) 160 LF

3118 Remove and Dispose Gutters, alum, 5" x 6" comb fascia & gutter, .032" thick, enameled (See Tech Specs.) 160 LF

3119Install Gutters, alum, 5" x 6" comb fascia & gutter, .032" thick,160LF
enameled (See Tech Specs.)
3120Remove and Dispose Gutters, steel, galv, half round or box, 28 ga, 5"104LF
wide, enameled (See Tech Specs.)
3121Install Gutters, steel, galv, half round or box, 28 ga, 5" wide,104LF
enameled (See Tech Specs.)

3122 Remove and Dispose Gravel stop, galv steel, 6" face height (See Tech Specs.) 104 LF

3123 Install Gravel stop, galv steel, 6" face height (See Tech Specs.) 104 LF

3124 Remove and Dispose Gravel stop, aluminum, .050" thick, 6" height, painted (See Tech Specs.) 104 LF

3125 Install Gravel stop, aluminum, .050" thick, 6" height, painted (See Tech Specs.) 104 LF

3126 Remove and Dispose Gravel Gravel stop, aluminum, .050" thick, 8" height, painted (See Tech Specs.) 104 LF

3127 Install Gravel stop, aluminum, .050" thick, 8" height, painted (See Tech Specs.) 104 LF

3128 Remove and Dispose Gravel Gravel Gutters, aluminum, 5" box type, .032" thick, plain (See Tech Specs.) 160 LF

3129Install Gutters, aluminum, 5" box type, .032" thick, plain (See Tech160LF
Specs.)

3130 Remove and Dispose Gutters, steel, galv, half round or box, 28 ga, 5" wide, plain (See Tech Specs.) 160 LF

3131 Install Gutters, steel, galv, half round or box, 28 ga, 5" wide, plain (See Tech Specs.) 160 LF

3132 Remove and Dispose Gravel stop, aluminum, .050" thick, 6" height, duranodic finish (See Tech Specs.) 104 LF

3133Install Gravel stop, aluminum, .050" thick, 6" height, duranodic finish104LF
(See Tech Specs.)

3134 Remove and Dispose Gravel stop, aluminum, .050" thick, 8" height, duranodic finish (See Tech Specs.) 104 LF

3135Install Gravel stop, aluminum, .050" thick, 8" height, duranodic finish104LF
(See Tech Specs.)

3136 Remove and Dispose Downspouts, aluminum 3" x 4", .024" thick, enameled (See Tech Specs.) 60 LF

3137 Install Downspouts, aluminum 3" x 4", .024" thick, enameled (See Tech Specs.) 60 LF

3138 Remove and Dispose Downspouts, steel, rectangular, plain, 28 ga, galvanized, 3" x 4" (See Tech Specs.) 60 LF

3139Install Downspouts, steel, rectangular, plain, 28 ga, galvanized,60LF
3" x 4" (See Tech Specs.)

3140 Remove and Dispose Downspouts, steel, rect, epoxy painted, 24 ga, corrugated, 3" x 4" (See Tech Specs.) 60 LF

3141Install Downspouts, steel, rect, epoxy painted, 24 ga, corrugated,60LF
3" x 4" (See Tech Specs.)

3142 Remove and Dispose Drip edge, aluminum, .016" thick, 5" wide, mill finish (See Tech Specs.) 60 LF

3143 Install Drip edge, aluminum, .016" thick, 5" wide, mill finish (See Tech Specs.) 60 LF

3144 Remove and Dispose and Dispose Drip edge, aluminum, .016" thick, 5" wide, white finish (See Tech Specs.) 60 LF

3145 Install Drip edge, aluminum, .016" thick, 5" wide, white finish (See Tech Specs.) 60 LF

3146 Remove and Dispose Drip edge, galvanized, 5" wide, mill finish (See Tech Specs.) 60 LF

3147 Install Drip edge, galvanized, 5" wide, mill finish (See Tech Specs.) 60 LF

3148 Remove and Dispose Elbows, aluminum, 3" x 4", .025" thick, embossed (See Tech Specs.) 26 EA

3149Install Elbows, aluminum, 3" x 4", .025" thick, embossed (See Tech26EA
Specs.)

3150 Remove and Dispose Elbows, aluminum, 3" x 4", .025" thick, enameled (See Tech Specs.) 26 EA

3151Install Elbows, aluminum, 3" x 4", .025" thick, enameled (See Tech26EA
Specs.)

3152 Remove and Dispose Flashing, aluminum, mill finish, .032" thick (See Tech Specs.) 90 SF

3153 Install Flashing, aluminum, mill finish, .032" thick (See Tech Specs.) 90 SF

3154 Remove and Dispose Vent flashing, aluminum with lead ring, 2" pipe (See Tech Specs.) 9 EA

3155 Install Vent flashing, aluminum with lead ring, 2" pipe (See Tech Specs.) 9 EA

3156 Remove and Dispose Vent flashing, aluminum with lead ring, 3" pipe (See Tech Specs.) 9 EA

3157 Install Vent flashing, aluminum with lead ring, 3" pipe (See Tech Specs.) 9 EA

3158 Remove and Dispose Vent flashing, aluminum with lead ring, 4" pipe (See Tech Specs.) 9 EA

3159 Install Vent flashing, aluminum with lead ring, 4" pipe (See Tech Specs.) 9 EA

3160 Remove and Dispose Vent flashing, aluminum with lead ring, 1-1/2" pipe (See Tech Specs.) 9 EA

3161Install Vent flashing, aluminum with lead ring, 1-1/2" pipe (See Tech9EA
Specs.)

3162 Remove and Dispose Reglet, counter flashing for above, 12" wide, .032" aluminum (See Tech Specs.) 44 LF

3163Install Reglet, counter flashing for above, 12" wide, .032" aluminum44LF
(See Tech Specs.)
3164Remove and Dispose Roof vents, mushroom for built-up roofs, PVC, 6"16EA
high

3165 Install Roof vents, mushroom for built-up roofs, PVC, 6" high 16 EA

3166 Remove and Dispose Vents, one-way, aluminum (See Tech Specs.) 16 EA

3167 Install Vents, one-way, aluminum (See Tech Specs.) 16 EA

3168 Remove and Dispose Drains-scppr flr, oblique strn-CI, 6"x7" top, 2", 3"&4" pipe size (See Tech Specs.) 4 EA

3169Install Drains-scppr flr, oblique strn-CI, 6"x7" top, 2", 3"&4" pipe size4EA
(See Tech Specs.)
3170Remove and Dispose Drains, roof, flat metal deck, C.I. body, 12" C.I.4EA
dome, 3" pipe size (See Tech Specs.)
3171Install Drains, roof, flat metal deck, C.I. body, 12" C.I. dome,4EA
3" pipe size (See Tech Specs.)

3172 Remove and Dispose Drains, roof, flat mtl deck, galvanized body, 12"CI dome, 6" pipe (See Tech Specs.) 4 EA

3173Install Drains, roof, flat mtl deck, galvanized body, 12"CI dome, 6" pipe4EA
(See Tech Specs.)

3174 Remove and Dispose Drains, cornice, C.I., 45< or 90< outlet, 3" and 4" pipe size (See Tech Specs.) 4 EA

3175Install Drains, cornice, C.I., 45< or 90< outlet, 3" and 4" pipe size4EA
(See Tech Specs.)

3176 Remove and Dispose Drains, cornice, C.I., for galvanized body, 3" and 4" pipe size (See Tech Specs.) 4 EA

3177Install Drains, cornice, C.I., for galvanized body, 3" and 4" pipe size4EA
(See Tech Specs.)

3178 Remove and Dispose Elastomeric rfg,poly spray-on W/20mil silicone rbr ctg , 3"thk,r21,min (See Tech Specs.) 1,600 SF

3179Install Elastomeric rfg,poly spray-on W/20mil silicone rbr ctg ,1,600SF
3"thk,r21,min (See Tech Specs.)

3180 Remove and Dispose Built-up rfg,asph fl CT W/gvl,ctd gl base sht,3ply gl,nailable dk (See Tech Specs.) 5,200 SF

3181Install Built-up rfg,asph fl CT W/gvl,ctd gl base sht,3ply gl,nailable dk5,200SF
(See Tech Specs.)
3182Remove and Dispose Built-up rfg,asph fl CT W/gvl,ctd gl base sht,4ply gl5,200SF
fbr felt,mopped
3183Install Built-up rfg,asph fl CT W/gvl,ctd gl base sht,4ply gl5,200SF
fbr felt,mopped

3184 Remove and Dispose Cants, 4" x 4" treated timber, cut diagonally (See Tech Specs.) 90 LF

3185 Install Cants, 4" x 4" treated timber, cut diagonally (See Tech Specs.) 90 LF

3186 Remove and Dispose B247Single-ply membrane, EPDM, 60 mil, 0.40 PS, fully adhered w/adhesive, w/4" seam tape (See Tech Specs.) 5,200 SF

3187Install B247Single-ply membrane, EPDM, 60 mil, 0.40 PS, fully5,200SF
adhered w/adhesive, w/4" seam tape (See Tech Specs.)
3188Remove and Dispose Mod bit rfng, SBS mod, gran surf cap sheet, poly rein, mppd, 160 mils w/base sheet, #15 Glass Fiber Felt fully mopped to1,040SF
deck w/asphalt primer (See Tech Specs.)
3189Install Mod bit rfng, SBS mod, gran surf cap sheet, poly rein, mppd,1,040SF
160 mils w/base sheet, #15 Glass Fiber Felt fully mopped to
deck w/asphalt primer (See Tech Specs.)
3190Remove and Dispose Mod bit, SBS mod, smooth surf cap sheet, glass fiber rein, mppd, 160 mils w/base sheet, #15 Glass Fiber Felt fully1,040SF
mopped to 160 mils w/base sheet, #15 Glass Fiber Felt deck w/asphalt
primer (See Tech Specs.)
3191Install Mod bit, SBS mod, smooth surf cap sheet, glass fiber rein, mppd,1,040SF
160 mils w/base sheet, #15 Glass Fiber Felt fully mopped to deck
w/asphalt primer (See Tech Specs.)
3192Remove and Dispose Mod bit, APP mod, gran surface cap sheet, poly1,040SF
rein, torched, 180 mils w/base sheet, #15 Glass Fiber Felt fully mopped to
deck w/asphalt primer (See Tech Specs.)
3193Install Mod bit, APP mod, gran surface cap sheet, poly rein,1,040SF
torched, 180 mils w/base sheet, #15 Glass Fiber Felt fully mopped to
deck w/asphalt primer (See Tech Specs.)
3194Remove and Dispose Mod bit, APP mod, smooth surf cap sheet, poly rein, torched, 160 mils w/base sheet, #15 Glass Fiber Felt fully mopped to1,040SF
deck w/asphalt primer (See Tech Specs.)
3195Install Mod bit, APP mod, smooth surf cap sheet, poly rein, torched,1,040SF
160 mils w/base sheet, #15 Glass Fiber Felt fully mopped to
deck w/asphalt primer (See Tech Specs.)

3196 Remove and Dispose Roof coatings, asphalt primer, 5 gallon (See Tech Specs.) 20,000 SF

3197 Install Roof coatings, asphalt primer, 5 gallon (See Tech Specs.) 20,000 SF

3198 Remove and Dispose Bituminous asphalt coating, with fibers, troweled on, 1/2" thick (See Tech Specs.) 2,000 SF

3199Install Bituminous asphalt coating, with fibers, troweled on, 1/2" thick2,000SF
(See Tech Specs.)

3200 Remove and DisposeBuilt-up rfg,asph fl CT,ctd gl fbr base sht,3 plies,on nailable dks (See Tech Specs.) 2,000 SF

3201Install Built-up rfg,asph fl CT,ctd gl fbr base sht,3 plies,on nailable dks2,000SF
(See Tech Specs.)

3202 Remove and Dispose Built-up rfg,asph fl CT,ctd gl fbr base sht,4ply gl fbr felt,mopped (See Tech Specs.) 2,000 SF

3203Install Built-up rfg,asph fl CT,ctd gl fbr base sht,4ply gl fbr felt,mopped2,000SF
(See Tech Specs.)

3204 Remove and Dispose Rubber coating, silicone or stearate, sprayed on CMU, 2 coats (See Tech Specs.) 1,040 SF

3205Install Rubber coating, silicone or stearate, sprayed on CMU, 2 coats1,040SF
(See Tech Specs.)

3206 Remove and Dispose Pitch Pockets, side extenders, 6" (See Tech Specs.) 18 EA

3207 Install Pitch Pockets, side extenders, 6" (See Tech Specs.) 18 EA

3208 Remove and Dispose Pitch Pockets, adjustable, 4" to 7", welded corners, 4" deep (See Tech Specs.) 18 EA

3209Install Pitch Pockets, adjustable, 4" to 7", welded corners, 4" deep18EA
(See Tech Specs.)

3210 Remove and Dispose Walkway for BUR, asph impregnated, 3' x 3' x 3/4" thk (See Tech Specs.) 700 SF

3211 Install Walkway for BUR, asph impregnated, 3' x 3' x 3/4" thk (See Tech Specs.) 700 SF

3212 Remove and Dispose Caulking & sealants, polyurethane, 1 or 2 component, bulk (See Tech Specs.) 90 LF

3213Install Caulking & sealants, polyurethane, 1 or 2 component, bulk90LF
(See Tech Specs.)

3214 Remove and Dispose Caulking and sealants, silicone rubber, cartridges (See Tech Specs.) 90 LF

3215Install Caulking and sealants, silicone rubber, cartridges (See Tech90LF
Specs.)

3216 Remove and Dispose Caulking and sealants, resin epoxy coating, 2 component, heavy duty (See Tech Specs.) 90 LF

3217Install Caulking and sealants, resin epoxy coating, 2 component, heavy90LF
duty (See Tech Specs.)

3218 Remove and Dispose Caulking and sealants, neoprene gaskets, closed cell, 1/4" x 3/4" (See Tech Specs.) 90 LF

3219Install Caulking and sealants, neoprene gaskets, closed cell, 1/4" x 3/4"90LF
(See Tech Specs.)

3220 Remove and Dispose Framing, miscellaneous, nailers, treated, wood construction, 2" x 6" (See Tech Specs.) 90 LF

3221Install Framing, miscellaneous, nailers, treated, wood construction, 2" x 6"90LF
(See Tech Specs.)

3222 Remove and Dispose Framing, miscellaneous, nailers, treated, wood construction, 2" x 4" (See Tech Specs.) 90 LF

3223Install Framing, miscellaneous, nailers, treated, wood construction, 2" x 4"90LF
(See Tech Specs.)

3224 Remove and Dispose Framing, miscellaneous, nailers, treated, wood construction, 2" x 8" (See Tech Specs.) 90 LF

3225Install Framing, miscellaneous, nailers, treated, wood construction, 2" x 8"90LF
(See Tech Specs.)

3226 Remove and Dispose Roof deck insul, polyisocyanurate, 2#/CF density, 2" thk R14.29 (See Tech Specs.) 5,000 SF

3227Install Roof deck insul, polyisocyanurate, 2#/CF density, 2" thk R14.295,000SF
(See Tech Specs.)
3228Remove and Dispose Roof deck insulation, polyisocyanurate 2#/CF5,000SF
density, tapered for drainage (See Tech Specs.)
3229Install Roof deck insulation, polyisocyanurate 2#/CF density,5,000SF
tapered for drainage (See Tech Specs.)

3230 Remove and Dispose Roof deck insulation, expanded polystyrene, 2" thick R7.69 (See Tech Specs.) 5,000 SF

3231Install Roof deck insulation, expanded polystyrene, 2" thick R7.695,000SF
(See Tech Specs.)

3232 Remove and Dispose Roof deck insulation, expanded polystyrene, tapered for drainage (See Tech Specs.) 880 SF

3233Install Roof deck insulation, expanded polystyrene, tapered for drainage880SF
(See Tech Specs.)
3234Remove and Dispose Roof deck insul., extruded polystyrene, 60 PSI4,000SF
comp. strength, 2" thick R10 (See Tech Specs.)
3235Install Roof deck insul., extruded polystyrene, 60 PSI comp.4,000SF
strength, 2" thick R10 (See Tech Specs.)

3236 Remove and Dispose Roof deck insul., extruded polystyrene, 60 PSI comp. strgth., tapered (See Tech Specs.) 1,040 SF

3237Install Roof deck insul., extruded polystyrene, 60 PSI comp. strgth.,1,040SF
tapered (See Tech Specs.)

3238 Remove and Dispose Roof hatch, 2'-6" x 3', w/curb, 1" fbgls insul, galv stl curb/cover (See Tech Specs.) 1 EA

3239Install Roof hatch, 2'-6" x 3', w/curb, 1" fbgls insul, galv stl curb/cover1EA
(See Tech Specs.)

3240 Remove and Dispose Skylight, insulated safety glass with aluminum frame (See Tech Specs.) 260 SF

3241 Install Skylight, insulated safety glass with aluminum frame (See Tech Specs.) 160 SF

3242 Remove and Dispose Ladder, steel, 20" wide, bolted to concrete, with cage (See Tech Specs.) 70 VLF

3243 Install Ladder, steel, 20" wide, bolted to concrete, with cage (See Tech Specs.) 70 VLF

3244 Remove and DisposeLadder, steel, 20" wide, bolted to concrete, w/o cage (See Tech Specs.) 70 VLF

3245 Install Ladder, steel, 20" wide, bolted to concrete, w/o cage (See Tech Specs.) 70 VLF

3246 Replace Insulation/finish syst, field applied, 1 inch (See Tech Specs.) 520 SF

3247 Replace Insulation/finish syst, field applied, 2 inch (See Tech Specs.) 260 SF

3248 Replace Insulation/finish syst, field applied, 3 inch (See Tech Specs.) 260 SF

3249 Replace Ductwork, galv steel, 500-1000 lb, 12"-14"h, 18"w (See Tech Specs.) 90 LB

3250 Replace Ductwork, galv steel, 500-1000 lb, 12"-14"h, 24"w (See Tech Specs.) 90 LB

3251 Replace Ductwork, galv steel, 500-1000 lb, 12"-14"h, 48"w (See Tech Specs.) 90 LB

3252 Pipe, copper, 3/8" dia., type K (See Tech Specs.) 160 LF

3253 Pipe insulation, 3/8" copper pipe, rubber tubing (See Tech Specs.) 160 LF

3254 Vent and Pipe Replacement, PVC schedule 40, 2" dia. (See Tech Specs.) 18 LF

3255 Vent and Pipe Replacement, PVC schedule 40, 3" dia. (See Tech Specs.) 18 LF

3256 Vent and Pipe Replacement, PVC schedule 40, 4" dia. (See Tech Specs.) 18 LF

3257 HVAC demo, Mech equipment (See Tech Specs.) 2,000 LBS

3258 Air cooled condenser, 2 tons, reinstallation (See Tech Specs.) 6 EA

3259 Air cooled condenser, 16 tons,reinstallation (See Tech Specs.) 6 EA

3260 Roof top unit, 7.5 tons, single zone, reinstallation (See Tech Specs.) 6 EA

3261 Replace Wire, 600 volt, type THW, copper, stranded, #12 (See Tech Specs.) 200 LF

3262 Replace Wire, 600 volt, type THW, copper, solid, #12 (See Tech Specs.) 200 LF

3263 Replace Wire, 600 volt, type THW, copper, stranded, #10 (See Tech Specs.) 200 LF

3264 Replace Wire, 600 volt, type THW, copper, solid, #10 (See Tech Specs.) 200 LF

3265Replace Wire, 600 volt, type THW, copper, stranded, #8 (See Tech200LF
Specs.)
3266Replace Wire, 600 volt, type THW, copper, stranded, #6 (See Tech200LF
Specs.)

3267 ReplaceWire, 600 volt, type THW, copper, stranded, #4 (See Tech Specs.) 200 LF

3268Replace Wire, 600 volt, type THW, copper, stranded, #3 (See Tech200LF
Specs.)
3269Replace Wire, 600 volt, type THW, copper, stranded, #2 (See Tech200LF
Specs.)
3270Replace Wire, 600 volt, type THW, copper, stranded, #1 (See Tech200LF
Specs.)

3271 Replace Wire, 600 volt, type THWN-THHN, copper, stranded, #12 (See Tech Specs.) 200 LF

3272 Replace Wire, 600 volt, type THWN-THHN, copper, solid, #12 (See Tech Specs.) 200 LF

3273 Replace Wire, 600 volt, type THWN-THHN, copper, stranded, #10 (See Tech Specs.) 200 LF

3274 Replace Wire, 600 volt, type THWN-THHN, copper, solid, #10 (See Tech Specs.) 200 LF

3275 Replace Wire, 600 volt, type THWN-THHN, copper, stranded, #8 (See Tech Specs.) 200 LF

3276 Replace Wire, 600 volt, type THWN-THHN, copper, stranded, #6 (See Tech Specs.) 200 LF

3277 Replace Wire, 600 volt, type THWN-THHN, copper, stranded, #4 (See Tech Specs.) 200 LF

3278 Replace Cond to 15' H,incl 2 termn,2 elb&11 bm CLP per 100',galv stl,1/2" dia (See Tech Specs.) 100 LF

3279 Replace Cond to 15' H,incl 2 termn,2 elb&11 bm CLP per 100',galv stl,3/4" dia (See Tech Specs.) 100 LF

3280Replace Cond to 15' H,incl 2 termn,2 elb&11 bm CLP per 100',galv stl,1"100LF
dia (See Tech Specs.)

3281 Replace Cond to 15' H,incl 2 termn,2 elb&11 bm CLP per 100',galv stl,1-1/4"dia (See Tech Specs.) 100 LF

3282 Replace Cond to 15' H,incl 2 termn,2 elb&11 bm CLP per 100',galv stl,1-1/2"dia (See Tech Specs.) 100 LF

3283Replace Cond to 15' H,incl 2 termn,2 elb&11 bm CLP per 100',galv stl,2"100LF
dia (See Tech Specs.)

3284 Replace Cond to 15' H,incl 2 termn,2 elb&11 bm CLP per 100',galv stl,2-1/2"dia (See Tech Specs.) 100 LF

3285Replace Cond to 15' H,incl 2 termn,2 elb&11 bm CLP per 100',galv stl,3"100LF
dia (See Tech Specs.)

3286 Replace Cond to 15' H,incl 2 termn,2 elb&11 bm CLP per 100',galv stl,3-1/2"dia (See Tech Specs.) 100 LF

3287Relace Cond to 15' H,incl 2 termn,2 elb&11 bm CLP per 100',galv stl,4"100LF
dia (See Tech Specs.)

3288 Replace Safety switches, heavy duty, 240 volt, 3 pole NEMA 1 fusible, 30 amp (See Tech Specs.) 8 EA

3289 Replace Safety switches, heavy duty, 240 volt, 3 pole NEMA 1 fusible, 60 amp (See Tech Specs.) 8 EA

3290 Replace Safety switches, heavy duty, 240 volt, 3 pole NEMA 1 fusible, 100 amp (See Tech Specs.) 8 EA

3291Replace Wire, 600 volt, type THW, copper, stranded, 1/0 (See Tech100LF
Specs.)
3292Replace Wire, 600 volt, type THW, copper, stranded, 2/0 (See Tech100LF
Specs.)
3293Replace Wire, 600 volt, type THW, copper, stranded, 3/0 (See Tech100LF
Specs.)
3294Replace Wire, 600 volt, type THW, copper, stranded, 4/0 (See Tech100LF
Specs.)

3295 Remove & dispose PUF or Built-up Roofing w/Asbestos Mastic (ACM) 100 SF

3001 Grand Total