FIRST-SchedulePrices_W912C320B0001_RoofRepairs_20200306.xlsx

XLSX spreadsheet 40 KB Posted

Attached to
Roof Inspection, Repairs and Maintenance at Fort Buchanan, Puerto Rico.
Solicitation number
W912C320B0001
Issued by

View the file

Other files

File Type Posted
BidAbstract_W912C320B0001_RoofRepairs_20200514.pdf PDF
Amend0007_W912C320B0001_RoofRepairs20200506.pdf PDF
Amend0006_W912C320B0001_RoofRepairs20200428.pdf PDF
Amend0005_W912C320B0001_RoofRepairs20200421.pdf PDF
Amend0004_W912C320B0001_RoofRepairs20200409.pdf PDF
Amend0003_W912C320B0001_RoofRepairs20200318.pdf PDF
Photo12Amend0002_W912C320B0001_RoofRepairs20200316.pdf PDF
Amend0002_W912C320B0001_RoofRepairs20200316.pdf PDF
Photo2Amend0002_W912C320B0001_RoofRepairs20200316.pdf PDF
Photo9Amend0002_W912C320B0001_RoofRepairs20200316.pdf PDF
Photo3Amend0002_W912C320B0001_RoofRepairs20200316.pdf PDF
Photo8Amend0002_W912C320B0001_RoofRepairs20200316.pdf PDF
Photo11Amend0002_W912C320B0001_RoofRepairs20200316.pdf PDF
Photo4Amend0002_W912C320B0001_RoofRepairs20200316.pdf PDF
Photo7Amend0002_W912C320B0001_RoofRepairs20200316.pdf PDF
Photo10Amend0002_W912C320B0001_RoofRepairs20200316.pdf PDF
Photo5Amend0002_W912C320B0001_RoofRepairs20200316.pdf PDF
Photo1Amend0002_W912C320B0001_RoofRepairs20200316.pdf PDF
Photo6Amend0002_W912C320B0001_RoofRepairs20200316.pdf PDF
Amend0001_W912C320B0001_RoofRepairs20200309.pdf PDF
BASE-SchedulePrices_W912C320B0001_RoofRepairs_20200306.xlsx XLSX spreadsheet
FOURTH-SchedulePrices_W912C320B0001_RoofRepairs_20200306.xlsx XLSX spreadsheet
Solicitation-W912C320B0001-RoofRepair-20200306.pdf PDF
SECOND-SchedulePrices_W912C320B0001_RoofRepairs_20200306.xlsx XLSX spreadsheet
Dwg_W912C320B0001-RoofRepair-20200306.pdf PDF
THIRD-SchedulePrices_W912C320B0001_RoofRepairs_20200306.xlsx XLSX spreadsheet
SOWSpecs_W912C320B0001-RoofRepairs-20200306.pdf PDF
Show all 27

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FIRST OPTION

SCHEDULE OF PRICES
FIRST OPTION PERIOD: IFB W912C320B0001, ROOF REPAIR INSPECTION & MAINTENANCE
ItemItem DescriptionEstimatedUnitUnit CostTotal Cost
Quantity
1001Roof Inspection Survey and Written Report with As-Built Roof Plan125,000SF
(Section 01 11 00, Para 1.2, 1.2.1, 1.2.2.a through h)

1002 Provide As-Built Roof Plans (Section 01 11 00, Para 1.2.2) 125,000 SF

1003Sampling & Laboratory Testing and Test Report for Asbestos Materials15EA
(Section 01 11 00, Para 1.2.2.e and Para 1.4.6)
1004Repair Concrete Roof (Plain Concrete)1,500SF
(Section 01 11 00, Para 1.4.1.a, b, c, d, e) (See Tech Specs.)
1005Repair Corrugated Metal Roof5,000SF
(Section 01 11 00, Para 1.4.2.a, b, c) (See Tech Specs.)
1006Remove and Dispose Corrugated Metal Roof Panels, GA 24520SF
(Section 01 11 00, Para 1.4.2.e) (See Tech Specs.)
1007Install Corrugated Metal Roof Panels, GA 24520SF
(Section 01 11 00, Para 1.4.2.e) (See Tech Specs.)
1008Remove and Dispose Corrugated Metal Roof Panels, GA 26520SF
(Section 01 11 00, Para 1.4.2.e) (See Tech Specs.)
1009Install Corrugated Metal Roof Panels, GA 26520SF
(Section 01 11 00, Para 1.4.2.e) (See Tech Specs.)
1010Repair Corrugated Metal Roof: Painting5,000SF
(Section 01 11 00, Para 1.4.2. d, f, and g)
1011Repair Modified Bitumen (Insulation, and 3-ply w/cold adhesvie)200SF
(See Tech Specs.)
1012Repair Modified Bitumen (Insulation, and 3-ply w/torched seams)200SF
(See Tech Specs.)
1013Repair Modified Bitumen (Insulation, and 2-ply w/cold200SF
adhesive or torched seams) (See Tech Specs.)
1014Repair Light weight Concrete insulation, Lt weight880SF
cellular roof fill, Port & Cem. 2 inch thick average and foaming agent
(See Tech Specs.)
1015Remove and Dispose Light weight Concrete insulation, Lt weight880SF
cellular roof fill, Port & Cem. 2 inch thick average and foaming agent
(See Tech Specs.)
1016Install Light weight Concrete insulation, Lt weight880SF
cellular roof fill, Port & Cem. 2 inch thick average and foaming agent
(See Tech Specs.)
1017Repair Light weight Concrete insulation, Lt weight880SF
cellular roof fill, Port & Cem. 4 inch thick average and foaming agent
(See Tech Specs.)
1018Remove and Dispose Light weight Concrete insulation, Lt weight880SF
cellular roof fill, Port & Cem. 4 inch thick average and foaming agent
(See Tech Specs.)
1019Install Light weight Concrete insulation, Lt weight880SF
cellular roof fill, Port & Cem. 4 inch thick average and foaming agent
(See Tech Specs.)

1020 Remove and Dispose Insulation 2-inch Average Thick (See Tech Specs.) 1,500 SF

1021 Install Insulation 2-inch Average Thick (See Tech Specs.) 1,500 SF

1022 Remove and Dispose E.P.D.M with Insulation (See Tech Specs.) 2,000 SF

1023 Install E.P.D.M with Insulation (See Tech Specs.) 2,000 SF

1024 Remove and Dispose Built-up Roofing (Insulation 3-ply, Hot Adhesive and Gravel) (See Tech Specs.) 5,000 SF

1025Install Built-up Roofing (Insulation 3-ply, Hot Adhesive and Gravel)5,000SF
(See Tech Specs.)
1026Repair Single Ply with adhesive or Asphalt Moppping1,040SF
(See Tech Specs.)

1027 Repair Insulation and Hot Asphalt Plies 520 SF

1028Remove and Dispose Standing Seam Metal Over Insulation260SF
(Section 07 61 13)

1029 Install Standing Seam Metal Over Insulation (Section 07 61 13) 260 SF

1030Remove and Dispose Asphalt Shingles over Insulation and over100SF
standing Seam Metal Roof (See Tech Specs.)
1031Install Asphalt Shingles over Insulation and over100SF
standing Seam Metal Roof (See Tech Specs.)

1032 Repair Water Proof Asphalt Coating (See Tech Specs.) 200 SF

1033Repair Sprayed Polyurethane with top Silicone Coating (PUF)7,800SF
(See Tech Specs.)
1034Remove and Dispose Primer and Elastomeric Coating7,800SF
(See Tech Specs.)

1035 Install Primer and Elastomeric Coating (See Tech Specs.) 7,800 SF

1036Blisters Repairs for Modified Bitumen260SF
(Section 01 11 00, Para 1.4.3) (See Tech Specs.)
1037Blister Repairs for E.P.D.M.520SF
(Section 01 11 00, Para 1.4.3) (See Tech Specs.)
1038Blister Repairs for Built-up Roofing1,040SF
(Section 01 11 00, Para 1.4.3) (See Tech Specs.)
1039Blister Repairs for PUF520SF
(Section 01 11 00, Para 1.4.5.d and e.(1) through (8) (See Tech Specs.)
1040PUF Minor Repairs260SF
(Section 01 11 00 , Para 1.4.5.C.(1) through (5) (See Tech Specs.)
1041PUF or Built-up Roofing Repairs w/Asbestos Mastic (ACM)260SF
(Section 01 11 00, Para 1.4.6) (See Tech Specs.)
1042PUF or Built-up Roofing Replacement w/Asbestos Mastic (ACM)5,200SF
(Section 01 11 00, Para 1.4.6) (See Tech Specs.)
1043Remove and Dispose Radiant Barrier Blanket130,000SF
Section 01 11 00, Para 1.5, 1.5.1 and 1.5.2) (See Tech Specs.)
1044Install Radiant Barrier Blanket130,000SF
Section 01 11 00, Para 1.5, 1.5.1 and 1.5.2) (See Tech Specs.)
1045Repair Cracks at Roofing Systems1,040LF
(Section 01 11 00, Para 1.4.3.e) (See Tech Specs.)
1046Correct Water Ponding Areas at Roofing Systems1,040SF
(Section 01 11 00, Para 1.4.3.d) (See Tech Specs.)
1047Maintenance for Roofing Systems130,000SF
(Section 01 11 00, Par1.9.a through c) (See Tech Specs.)
1048Cement parging, 2 coats, waterproofed Portland cement (See Tech1,040SF
Specs.)
1049Structural steel projects, steel surface treatments, wire brush, hand520SF
sanding (See Tech Specs.)
1050Struct. steel projects,sprayed painting,univ primer plus1 paint coat,520SF
phenolic, modified alkyd (See Tech Specs.)
1051Near white blast, (SSPC-10), exist coat blistered/pitted,520SF
9.0 #/SF (See Tech Specs.)
1052Structural steel project,pnts&prot ctg,sprayed,zinc rich primer,epoxy,520SF
spray,organic (See Tech Specs.)

1053 Strl st projs, pnts & prot ctg, sprayed, epoxy, intmd or topcoat (See Tech Specs.) 520 SF

1054Epoxy dk ctg, bitumen modified polyurethane, fld applied,520SF
55 mils thk (See Tech Specs.)

1055 Remove and Dispose Open web joist girders, average (See Tech Specs.) 1 TON

1056 Install Open web joist girders, average (See Tech Specs.) 1 TON

1057 Remove and Dispose Lightweight framing, angle, field fab, 3" x 3" x 3/8" (See Tech Specs.) 45 LF

1058Install Lightweight framing, angle, field fab, 3" x 3" x 3/8" (See Tech45LF
Specs.)

1059 Remove and Dispose Framing, joists, 2" x 12" (See Tech Specs.) 55 LF

1060 Install Framing, joists, 2" x 12" (See Tech Specs.) 55 LF

1061 Remove and Dispose Framing, joists, 2" x 4" (See Tech Specs.) 55 LF

1062 Install Framing, joists, 2" x 4" (See Tech Specs.) 55 LF

1063 Remove and Dispose Framing, joists, 2" x 6" (See Tech Specs.) 55 LF

1064 Install Framing, joists, 2" x 6" (See Tech Specs.) 55 LF

1065 Remove and Dispose Framing, joists, 2" x 8" (See Tech Specs.) 55 LF

1066 Install Framing, joists, 2" x 8" (See Tech Specs.) 55 LF

1067 Remove and Dispose Framing, joists, 2" x 10" (See Tech Specs.) 55 LF

1068 Install Framing, joists, 2" x 10" (See Tech Specs.) 55 LF

1069 Remove and Dispose Framing, roofs, fascia boards, 2" x 8" (See Tech Specs.) 55 LF

1070 Install Framing, roofs, fascia boards, 2" x 8" (See Tech Specs.) 55 LF

1071 Remove and Dispose Framing, roofs, rafters, to 4 in 12 pitch, 2" x 8" (See Tech Specs.) 55 LF

1072 Install Framing, roofs, rafters, to 4 in 12 pitch, 2" x 8" (See Tech Specs.) 55 LF

1073 Remove and Dispose Framing, roofs, rafters, to 4 in 12 pitch, 2" x 6" (See Tech Specs.) 55 LF

1074 Install Framing, roofs, rafters, to 4 in 12 pitch, 2" x 6" (See Tech Specs.) 55 LF

1075 Remove and Dispose Framing, roofs, ridge board, #2 or better, 1" x 8" (See Tech Specs.) 55 LF

1076 Install Framing, roofs, ridge board, #2 or better, 1" x 8" (See Tech Specs.) 55 LF

1077 Remove and Dispose Framing, roofs, roof cants, split, 4" x 4" (See Tech Specs.) 55 LF

1078 Install Framing, roofs, roof cants, split, 4" x 4" (See Tech Specs.) 55 LF

1079 Remove and Dispose Framing, miscellaneous, nailers, treated, wood construction, 2" x 6" (See Tech Specs.) 55 LF

1080Install Framing, miscellaneous, nailers, treated, wood construction,55LF
2" x 6" (See Tech Specs.)

1081 Remove and Dispose Exp jt,butyl or nprn ctr W/foam insul,alum,.032"thk for opng to 2-1/2" (See Tech Specs.) 104 LF

1082Install Exp jt,butyl or nprn ctr W/foam insul,alum,.032"thk for opng to104LF
2-1/2" (See Tech Specs.)
1083Remove and Dispose Exp jt, butyl or nprn ctr W/foam insul, alum, for jt opngs to104LF
3-1/2" (See Tech Specs.)
1084Install Exp jt, butyl or nprn ctr W/foam insul, alum, for jt opngs to104LF
3-1/2" (See Tech Specs.)

1085 Remove and Dispose Expansion joint, roof joint with extruded aluminum cover, 2" (See Tech Specs.) 55 LF

1086 Install Expansion joint, roof joint with extruded aluminum cover, 2" (See Tech Specs.) 55 LF

1087Remove and Dispose Expansion joint, roof to wall joint with extruded aluminum cover55LF
(See Tech Specs.)
1088Install Expansion joint, roof to wall joint with extruded aluminum cover55LF
(See Tech Specs.)
1089Remove and Dispose Expansion joint, wall joint, closed cell foam on PVC55LF
cover, 9" wide (See Tech Specs.)
1090Remove and Dispose Expansion joint, wall joint, closed cell foam on PVC55LF
cover, 9" wide (See Tech Specs.)

1091 Remove and Dispose Expansion jt, neoprene, dbl-seal type with thick center, 4-1/2" wide (See Tech Specs.) 55 LF

1092Install Expansion jt, neoprene, dbl-seal type with thick center,55LF
4-1/2" wide (See Tech Specs.)

1093 Cleaning high pressure water only, minimum (See Tech Specs.) 130,000 SF

1094 Remove and Dispose Sheathing, with boards, 1" x 12" boards, laid diagonal (See Tech Specs.) 55 SF

1095 Install Sheathing, with boards, 1" x 12" boards, laid diagonal (See Tech Specs.) 55 SF

1096 Remove and Dispose Sheathing, plywood on roof, CDX, 5/8" thick (See Tech Specs.) 55 SF

1097 Install Sheathing, plywood on roof, CDX, 5/8" thick (See Tech Specs.) 55 SF

1098 Remove and Dispose Steel roofing, on steel frame, corrugated or ribbed, galv, 24 ga (See Tech Specs.) 55 SF

1099Install Steel roofing, on steel frame, corrugated or ribbed, galv, 24 ga55SF
(See Tech Specs.)

1100 Remove and Dispose Steel roofing, on steel frame, corrugated or ribbed, galv, 26 ga (See Tech Specs.) 55 SF

1101Install Steel roofing, on steel frame, corrugated or ribbed, galv, 26 ga55SF
(See Tech Specs.)

1102 Remove and Dispose roof flat profile, 1-3/4" stand. seams, 12" w, stand. fin. 24 ga. (See Tech Specs.) 55 SF

1103Install Steel roof flat profile, 1-3/4" stand. seams, 12" w, stand. fin. 24 ga.55SF
(See Tech Specs.)

1104 Remove and Dispose Aluminum roofing, corrugated, painted, .032" thick (See Tech Specs.) 55 SF

1105Install Aluminum roofing, corrugated, painted, .032" thick (See Tech55SF
Specs.)

1106 Remove and Dispose Asphalt shingles, #15 felt underlayment (See Tech Specs.) 55 SF

1107 Install Asphalt shingles, #15 felt underlayment (See Tech Specs.) 55 SF

1108 Remove and Dispose Asphalt shingles, std strip shingles, inorganic, class A, 210-235 lb/sq (See Tech Specs.) 55 SF

1109Install Asphalt shingles, std strip shingles, inorganic, class A,55SF
210-235 lb/sq (See Tech Specs.)

1110 Remove and Dispose Steel roofing, ridge, galvanized, 20" wide (See Tech Specs.) 55 LF

1111 Install Steel roofing, ridge, galvanized, 20" wide (See Tech Specs.) 55 LF

1112 Remove and Dispose Fascia, aluminum, .032" thick, colored, NO furring included (See Tech Specs.) 55 SF

1113Install Fascia, aluminum, .032" thick, colored, NO furring included55SF
(See Tech Specs.)
1114Remove and Dispose Fascia, steel, galv and enameled, stock, NO furring,55SF
long panels (See Tech Specs.)
1115Install Fascia, steel, galv and enameled, stock, NO furring,55SF
long panels (See Tech Specs.)

1116 Remove and Dispose Gutters, aluminum, 5" box type, enameled (See Tech Specs.) 160 LF

1117 Install Gutters, aluminum, 5" box type, enameled (See Tech Specs.) 160 LF

1118 Remove and Dispose Gutters, alum, 5" x 6" comb fascia & gutter, .032" thick, enameled (See Tech Specs.) 160 LF

1119Install Gutters, alum, 5" x 6" comb fascia & gutter, .032" thick,160LF
enameled (See Tech Specs.)
1120Remove and Dispose Gutters, steel, galv, half round or box, 28 ga, 5"104LF
wide, enameled (See Tech Specs.)
1121Install Gutters, steel, galv, half round or box, 28 ga, 5" wide,104LF
enameled (See Tech Specs.)

1122 Remove and Dispose Gravel stop, galv steel, 6" face height (See Tech Specs.) 104 LF

1123 Install Gravel stop, galv steel, 6" face height (See Tech Specs.) 104 LF

1124 Remove and Dispose Gravel stop, aluminum, .050" thick, 6" height, painted (See Tech Specs.) 104 LF

1125 Install Gravel stop, aluminum, .050" thick, 6" height, painted (See Tech Specs.) 104 LF

1126 Remove and Dispose Gravel Gravel stop, aluminum, .050" thick, 8" height, painted (See Tech Specs.) 104 LF

1127 Install Gravel stop, aluminum, .050" thick, 8" height, painted (See Tech Specs.) 104 LF

1128 Remove and Dispose Gravel Gravel Gutters, aluminum, 5" box type, .032" thick, plain (See Tech Specs.) 160 LF

1129Install Gutters, aluminum, 5" box type, .032" thick, plain (See Tech160LF
Specs.)

1130 Remove and Dispose Gutters, steel, galv, half round or box, 28 ga, 5" wide, plain (See Tech Specs.) 160 LF

1131 Install Gutters, steel, galv, half round or box, 28 ga, 5" wide, plain (See Tech Specs.) 160 LF

1132 Remove and Dispose Gravel stop, aluminum, .050" thick, 6" height, duranodic finish (See Tech Specs.) 104 LF

1133Install Gravel stop, aluminum, .050" thick, 6" height, duranodic finish104LF
(See Tech Specs.)

1134 Remove and Dispose Gravel stop, aluminum, .050" thick, 8" height, duranodic finish (See Tech Specs.) 104 LF

1135Install Gravel stop, aluminum, .050" thick, 8" height, duranodic finish104LF
(See Tech Specs.)

1136 Remove and Dispose Downspouts, aluminum 3" x 4", .024" thick, enameled (See Tech Specs.) 60 LF

1137 Install Downspouts, aluminum 3" x 4", .024" thick, enameled (See Tech Specs.) 60 LF

1138Remove and Dispose Downspouts, steel, rectangular, plain, 28 ga, galvanized,60LF
3" x 4" (See Tech Specs.)
1139Install Downspouts, steel, rectangular, plain, 28 ga, galvanized,60LF
3" x 4" (See Tech Specs.)
1140Remove and Dispose Downspouts, steel, rect, epoxy painted, 24 ga, corrugated,60LF
3" x 4" (See Tech Specs.)
1141Install Downspouts, steel, rect, epoxy painted, 24 ga, corrugated,60LF
3" x 4" (See Tech Specs.)

1142 Remove and Dispose Drip edge, aluminum, .016" thick, 5" wide, mill finish (See Tech Specs.) 60 LF

1143 Install Drip edge, aluminum, .016" thick, 5" wide, mill finish (See Tech Specs.) 60 LF

1144 Remove and Dispose and Dispose Drip edge, aluminum, .016" thick, 5" wide, white finish (See Tech Specs.) 60 LF

1145 Install Drip edge, aluminum, .016" thick, 5" wide, white finish (See Tech Specs.) 60 LF

1146 Remove and Dispose Drip edge, galvanized, 5" wide, mill finish (See Tech Specs.) 60 LF

1147 Install Drip edge, galvanized, 5" wide, mill finish (See Tech Specs.) 60 LF

1148 Remove and Dispose Elbows, aluminum, 3" x 4", .025" thick, embossed (See Tech Specs.) 26 EA

1149Install Elbows, aluminum, 3" x 4", .025" thick, embossed (See Tech26EA
Specs.)

1150 Remove and Dispose Elbows, aluminum, 3" x 4", .025" thick, enameled (See Tech Specs.) 26 EA

1151Install Elbows, aluminum, 3" x 4", .025" thick, enameled (See Tech26EA
Specs.)

1152 Remove and Dispose Flashing, aluminum, mill finish, .032" thick (See Tech Specs.) 90 SF

1153 Install Flashing, aluminum, mill finish, .032" thick (See Tech Specs.) 90 SF

1154 Remove and Dispose Vent flashing, aluminum with lead ring, 2" pipe (See Tech Specs.) 9 EA

1155 Install Vent flashing, aluminum with lead ring, 2" pipe (See Tech Specs.) 9 EA

1156 Remove and Dispose Vent flashing, aluminum with lead ring, 3" pipe (See Tech Specs.) 9 EA

1157 Install Vent flashing, aluminum with lead ring, 3" pipe (See Tech Specs.) 9 EA

1158 Remove and Dispose Vent flashing, aluminum with lead ring, 4" pipe (See Tech Specs.) 9 EA

1159 Install Vent flashing, aluminum with lead ring, 4" pipe (See Tech Specs.) 9 EA

1160 Remove and Dispose Vent flashing, aluminum with lead ring, 1-1/2" pipe (See Tech Specs.) 9 EA

1161Install Vent flashing, aluminum with lead ring, 1-1/2" pipe (See Tech9EA
Specs.)

1162 Remove and Dispose Reglet, counter flashing for above, 12" wide, .032" aluminum (See Tech Specs.) 44 LF

1163Install Reglet, counter flashing for above, 12" wide, .032" aluminum44LF
(See Tech Specs.)
1164Remove and Dispose Roof vents, mushroom for built-up roofs, PVC, 6"16EA
high

1165 Install Roof vents, mushroom for built-up roofs, PVC, 6" high 16 EA

1166 Remove and Dispose Vents, one-way, aluminum (See Tech Specs.) 16 EA

1167 Install Vents, one-way, aluminum (See Tech Specs.) 16 EA

1168 Remove and Dispose Drains-scppr flr, oblique strn-CI, 6"x7" top, 2", 3"&4" pipe size (See Tech Specs.) 4 EA

1169Install Drains-scppr flr, oblique strn-CI, 6"x7" top, 2", 3"&4" pipe size4EA
(See Tech Specs.)
1170Remove and Dispose Drains, roof, flat metal deck, C.I. body, 12" C.I.4EA
dome, 3" pipe size (See Tech Specs.)
1171Install Drains, roof, flat metal deck, C.I. body, 12" C.I. dome,4EA
3" pipe size (See Tech Specs.)

1172 Remove and Dispose Drains, roof, flat mtl deck, galvanized body, 12"CI dome, 6" pipe (See Tech Specs.) 4 EA

1173Install Drains, roof, flat mtl deck, galvanized body, 12"CI dome, 6" pipe4EA
(See Tech Specs.)

1174 Remove and Dispose Drains, cornice, C.I., 45< or 90< outlet, 3" and 4" pipe size (See Tech Specs.) 4 EA

1175Install Drains, cornice, C.I., 45< or 90< outlet, 3" and 4" pipe size4EA
(See Tech Specs.)

1176 Remove and Dispose Drains, cornice, C.I., for galvanized body, 3" and 4" pipe size (See Tech Specs.) 4 EA

1177Install Drains, cornice, C.I., for galvanized body, 3" and 4" pipe size4EA
(See Tech Specs.)

1178 Remove and Dispose Elastomeric rfg,poly spray-on W/20mil silicone rbr ctg , 3"thk,r21,min (See Tech Specs.) 1,600 SF

1179Install Elastomeric rfg,poly spray-on W/20mil silicone rbr ctg ,1,600SF
3"thk,r21,min (See Tech Specs.)

1180 Remove and Dispose Built-up rfg,asph fl CT W/gvl,ctd gl base sht,3ply gl,nailable dk (See Tech Specs.) 5,200 SF

1181Install Built-up rfg,asph fl CT W/gvl,ctd gl base sht,3ply gl,nailable dk5,200SF
(See Tech Specs.)
1182Remove and Dispose Built-up rfg,asph fl CT W/gvl,ctd gl base sht,4ply gl5,200SF
fbr felt,mopped
1183Install Built-up rfg,asph fl CT W/gvl,ctd gl base sht,4ply gl5,200SF
fbr felt,mopped

1184 Remove and Dispose Cants, 4" x 4" treated timber, cut diagonally (See Tech Specs.) 90 LF

1185 Install Cants, 4" x 4" treated timber, cut diagonally (See Tech Specs.) 90 LF

1186 Remove and Dispose B247Single-ply membrane, EPDM, 60 mil, 0.40 PS, fully adhered w/adhesive, w/4" seam tape (See Tech Specs.) 5,200 SF

1187Install B247Single-ply membrane, EPDM, 60 mil, 0.40 PS, fully5,200SF
adhered w/adhesive, w/4" seam tape (See Tech Specs.)
1188Remove and Dispose Mod bit rfng, SBS mod, gran surf cap sheet, poly rein, mppd, 160 mils w/base sheet, #15 Glass Fiber Felt fully1,040SF
mopped to deck w/asphalt primer (See Tech Specs.)
1189Install Mod bit rfng, SBS mod, gran surf cap sheet, poly rein, mppd,1,040SF
160 mils w/base sheet, #15 Glass Fiber Felt fully mopped to
deck w/asphalt primer (See Tech Specs.)
1190Remove and Dispose Mod bit, SBS mod, smooth surf cap sheet, glass fiber rein, mppd, 160 mils w/base sheet, #15 Glass Fiber Felt fully1,040SF
mopped to deck w/asphalt primer (See Tech Specs.)
1191Install Mod bit, SBS mod, smooth surf cap sheet, glass fiber rein, mppd,1,040SF
160 mils w/base sheet, #15 Glass Fiber Felt fully mopped to
deck w/asphalt primer (See Tech Specs.)
1192Remove and Dispose Mod bit, APP mod, gran surface cap sheet, poly1,040SF
rein, torched, 180 mils w/base sheet, #15 Glass Fiber Felt fully mopped to
deck w/asphalt primer (See Tech Specs.)
1193Install Mod bit, APP mod, gran surface cap sheet, poly rein,1,040SF
torched, 180 mils w/base sheet, #15 Glass Fiber Felt fully mopped to
deck w/asphalt primer (See Tech Specs.)
1194Remove and Dispose Mod bit, APP mod, smooth surf cap sheet, poly rein, torched,1,040SF
160 mils w/base sheet, #15 Glass Fiber Felt fully mopped to
deck w/asphalt primer (See Tech Specs.)
1195Install Mod bit, APP mod, smooth surf cap sheet, poly rein, torched,1,040SF
160 mils w/base sheet, #15 Glass Fiber Felt fully mopped to
deck w/asphalt primer (See Tech Specs.)

1196 Remove and Dispose Roof coatings, asphalt primer, 5 gallon (See Tech Specs.) 20,000 SF

1197 Install Roof coatings, asphalt primer, 5 gallon (See Tech Specs.) SF

1198 Remove and Dispose Bituminous asphalt coating, with fibers, troweled on, 1/2" thick (See Tech Specs.) 2,600 SF

1199Install Bituminous asphalt coating, with fibers, troweled on, 1/2" thick2,600SF
(See Tech Specs.)

1200 Remove and DisposeBuilt-up rfg,asph fl CT,ctd gl fbr base sht,3 plies,on nailable dks (See Tech Specs.) 2,600 SF

1201Install Built-up rfg,asph fl CT,ctd gl fbr base sht,3 plies,on nailable dks2,600SF
(See Tech Specs.)

1202 Remove and Dispose Built-up rfg,asph fl CT,ctd gl fbr base sht,4ply gl fbr felt,mopped (See Tech Specs.) 2,600 SF

1203Install Built-up rfg,asph fl CT,ctd gl fbr base sht,4ply gl fbr felt,mopped2,600SF
(See Tech Specs.)

1204 Remove and Dispose Rubber coating, silicone or stearate, sprayed on CMU, 2 coats (See Tech Specs.) 1,040 SF

1205Install Rubber coating, silicone or stearate, sprayed on CMU, 2 coats1,040SF
(See Tech Specs.)

1206 Remove and Dispose Pitch Pockets, side extenders, 6" (See Tech Specs.) 18 EA

1207 Install Pitch Pockets, side extenders, 6" (See Tech Specs.) 18 EA

1208 Remove and Dispose Pitch Pockets, adjustable, 4" to 7", welded corners, 4" deep (See Tech Specs.) 18 EA

1209Install Pitch Pockets, adjustable, 4" to 7", welded corners, 4" deep18EA
(See Tech Specs.)

1210 Remove and Dispose Walkway for BUR, asph impregnated, 3' x 3' x 3/4" thk (See Tech Specs.) 700 SF

1211 Install Walkway for BUR, asph impregnated, 3' x 3' x 3/4" thk (See Tech Specs.) 700 SF

1212Remove and Dispose Caulking & sealants, polyurethane, 1 or 2 component, bulk90LF
(See Tech Specs.)
1213Install Caulking & sealants, polyurethane, 1 or 2 component, bulk90LF
(See Tech Specs.)

1214 Remove and Dispose Caulking and sealants, silicone rubber, cartridges (See Tech Specs.) 90 LF

1215Install Caulking and sealants, silicone rubber, cartridges (See Tech90LF
Specs.)

1216 Remove and Dispose Caulking and sealants, resin epoxy coating, 2 component, heavy duty (See Tech Specs.) 90 LF

1217Install Caulking and sealants, resin epoxy coating, 2 component, heavy90LF
duty (See Tech Specs.)

1218 Remove and Dispose Caulking and sealants, neoprene gaskets, closed cell, 1/4" x 3/4" (See Tech Specs.) 90 LF

1219Install Caulking and sealants, neoprene gaskets, closed cell, 1/4" x 3/4"90LF
(See Tech Specs.)

1220 Remove and Dispose Framing, miscellaneous, nailers, treated, wood construction, 2" x 6" (See Tech Specs.) 90 LF

1221Install Framing, miscellaneous, nailers, treated, wood construction, 2" x 6"90LF
(See Tech Specs.)

1222 Remove and Dispose Framing, miscellaneous, nailers, treated, wood construction, 2" x 4" (See Tech Specs.) 90 LF

1223Install Framing, miscellaneous, nailers, treated, wood construction, 2" x 4"90LF
(See Tech Specs.)

1224 Remove and Dispose Framing, miscellaneous, nailers, treated, wood construction, 2" x 8" (See Tech Specs.) 90 LF

1225Install Framing, miscellaneous, nailers, treated, wood construction, 2" x 8"90LF
(See Tech Specs.)

1226 Remove and Dispose Roof deck insul, polyisocyanurate, 2#/CF density, 2" thk R14.29 (See Tech Specs.) 5,000 SF

1227Install Roof deck insul, polyisocyanurate, 2#/CF density, 2" thk R14.295,000SF
(See Tech Specs.)
1228Remove and Dispose Roof deck insulation, polyisocyanurate 2#/CF5,000SF
density, tapered for drainage (See Tech Specs.)
1229Install Roof deck insulation, polyisocyanurate 2#/CF density,5,000SF
tapered for drainage (See Tech Specs.)

1230 Remove and Dispose Roof deck insulation, expanded polystyrene, 2" thick R7.69 (See Tech Specs.) 5,000 SF

1231Install Roof deck insulation, expanded polystyrene, 2" thick R7.695,000SF
(See Tech Specs.)

1232 Remove and Dispose Roof deck insulation, expanded polystyrene, tapered for drainage (See Tech Specs.) 880 SF

1233Install Roof deck insulation, expanded polystyrene, tapered for drainage880SF
(See Tech Specs.)
1234Remove and Dispose Roof deck insul., extruded polystyrene, 60 PSI4,000SF
comp. strength, 2" thick R10 (See Tech Specs.)
1235Install Roof deck insul., extruded polystyrene, 60 PSI comp.4,000SF
strength, 2" thick R10 (See Tech Specs.)

1236 Remove and Dispose Roof deck insul., extruded polystyrene, 60 PSI comp. strgth., tapered (See Tech Specs.) 1,040 SF

1237Install Roof deck insul., extruded polystyrene, 60 PSI comp. strgth.,1,040SF
tapered (See Tech Specs.)

1238 Remove and Dispose Roof hatch, 2'-6" x 3', w/curb, 1" fbgls insul, galv stl curb/cover (See Tech Specs.) 1 EA

1239Install Roof hatch, 2'-6" x 3', w/curb, 1" fbgls insul, galv stl curb/cover1EA
(See Tech Specs.)

1240 Remove and Dispose Skylight, insulated safety glass with aluminum frame (See Tech Specs.) 260 SF

1241 Install Skylight, insulated safety glass with aluminum frame (See Tech Specs.) 160 SF

1242 Remove and Dispose Ladder, steel, 20" wide, bolted to concrete, with cage (See Tech Specs.) 70 VLF

1243 Install Ladder, steel, 20" wide, bolted to concrete, with cage (See Tech Specs.) 70 VLF

1244 Remove and DisposeLadder, steel, 20" wide, bolted to concrete, w/o cage (See Tech Specs.) 70 VLF

1245 Install Ladder, steel, 20" wide, bolted to concrete, w/o cage (See Tech Specs.) 70 VLF

1246 Replace Insulation/finish syst, field applied, 1 inch (See Tech Specs.) 520 SF

1247 Replace Insulation/finish syst, field applied, 2 inch (See Tech Specs.) 260 SF

1248 Replace Insulation/finish syst, field applied, 3 inch (See Tech Specs.) 260 SF

1249 Replace Ductwork, galv steel, 500-1000 lb, 12"-14"h, 18"w (See Tech Specs.) 90 LB

1250 Replace Ductwork, galv steel, 500-1000 lb, 12"-14"h, 24"w (See Tech Specs.) 90 LB

1251 Replace Ductwork, galv steel, 500-1000 lb, 12"-14"h, 48"w (See Tech Specs.) 90 LB

1252 Pipe, copper, 3/8" dia., type K (See Tech Specs.) 160 LF

1253 Pipe insulation, 3/8" copper pipe, rubber tubing (See Tech Specs.) 160 LF

1254 Vent and Pipe Replacement, PVC schedule 40, 2" dia. (See Tech Specs.) 18 LF

1255 Vent and Pipe Replacement, PVC schedule 40, 3" dia. (See Tech Specs.) 18 LF

1256 Vent and Pipe Replacement, PVC schedule 40, 4" dia. (See Tech Specs.) 18 LF

1257 HVAC demo, Mech equipment (See Tech Specs.) 2,000 LBS

1258 Air cooled condenser, 2 tons, reinstallation (See Tech Specs.) 6 EA

1259 Air cooled condenser, 16 tons,reinstallation (See Tech Specs.) 6 EA

1260 Roof top unit, 7.5 tons, single zone, reinstallation (See Tech Specs.) 6 EA

1261 Replace Wire, 600 volt, type THW, copper, stranded, #12 (See Tech Specs.) 200 LF

1262 Replace Wire, 600 volt, type THW, copper, solid, #12 (See Tech Specs.) 200 LF

1263 Replace Wire, 600 volt, type THW, copper, stranded, #10 (See Tech Specs.) 200 LF

1264 Replace Wire, 600 volt, type THW, copper, solid, #10 (See Tech Specs.) 200 LF

1265Replace Wire, 600 volt, type THW, copper, stranded, #8 (See Tech200LF
Specs.)
1266Replace Wire, 600 volt, type THW, copper, stranded, #6 (See Tech200LF
Specs.)

1267 ReplaceWire, 600 volt, type THW, copper, stranded, #4 (See Tech Specs.) 200 LF

1268Replace Wire, 600 volt, type THW, copper, stranded, #3 (See Tech200LF
Specs.)
1269Replace Wire, 600 volt, type THW, copper, stranded, #2 (See Tech200LF
Specs.)
1270Replace Wire, 600 volt, type THW, copper, stranded, #1 (See Tech200LF
Specs.)

1271 Replace Wire, 600 volt, type THWN-THHN, copper, stranded, #12 (See Tech Specs.) 200 LF

1272 Replace Wire, 600 volt, type THWN-THHN, copper, solid, #12 (See Tech Specs.) 200 LF

1273 Replace Wire, 600 volt, type THWN-THHN, copper, stranded, #10 (See Tech Specs.) 200 LF

1274 Replace Wire, 600 volt, type THWN-THHN, copper, solid, #10 (See Tech Specs.) 200 LF

1275 Replace Wire, 600 volt, type THWN-THHN, copper, stranded, #8 (See Tech Specs.) 200 LF

1276 Replace Wire, 600 volt, type THWN-THHN, copper, stranded, #6 (See Tech Specs.) 200 LF

1277 Replace Wire, 600 volt, type THWN-THHN, copper, stranded, #4 (See Tech Specs.) 200 LF

1278 Replace Cond to 15' H,incl 2 termn,2 elb&11 bm CLP per 100',galv stl,1/2" dia (See Tech Specs.) 100 LF

1279 Replace Cond to 15' H,incl 2 termn,2 elb&11 bm CLP per 100',galv stl,3/4" dia (See Tech Specs.) 100 LF

1280Replace Cond to 15' H,incl 2 termn,2 elb&11 bm CLP per 100',galv stl,1"100LF
dia (See Tech Specs.)

1281 Replace Cond to 15' H,incl 2 termn,2 elb&11 bm CLP per 100',galv stl,1-1/4"dia (See Tech Specs.) 100 LF

1282 Replace Cond to 15' H,incl 2 termn,2 elb&11 bm CLP per 100',galv stl,1-1/2"dia (See Tech Specs.) 100 LF

1283Replace Cond to 15' H,incl 2 termn,2 elb&11 bm CLP per 100',galv stl,2"100LF
dia (See Tech Specs.)

1284 Replace Cond to 15' H,incl 2 termn,2 elb&11 bm CLP per 100',galv stl,2-1/2"dia (See Tech Specs.) 100 LF

1285Replace Cond to 15' H,incl 2 termn,2 elb&11 bm CLP per 100',galv stl,3"100LF
dia (See Tech Specs.)

1286 Replace Cond to 15' H,incl 2 termn,2 elb&11 bm CLP per 100',galv stl,3-1/2"dia (See Tech Specs.) 100 LF

1287Relace Cond to 15' H,incl 2 termn,2 elb&11 bm CLP per 100',galv stl,4"100LF
dia (See Tech Specs.)

1288 Replace Safety switches, heavy duty, 240 volt, 3 pole NEMA 1 fusible, 30 amp (See Tech Specs.) 8 EA

1289 Replace Safety switches, heavy duty, 240 volt, 3 pole NEMA 1 fusible, 60 amp (See Tech Specs.) 8 EA

1290 Replace Safety switches, heavy duty, 240 volt, 3 pole NEMA 1 fusible, 100 amp (See Tech Specs.) 8 EA

1291Replace Wire, 600 volt, type THW, copper, stranded, 1/0 (See Tech100LF
Specs.)
1292Replace Wire, 600 volt, type THW, copper, stranded, 2/0 (See Tech100LF
Specs.)
1293Replace Wire, 600 volt, type THW, copper, stranded, 3/0 (See Tech100LF
Specs.)
1294Replace Wire, 600 volt, type THW, copper, stranded, 4/0 (See Tech100LF
Specs.)

1295 Remove & dispose PUF or Built-up Roofing w/Asbestos Mastic (ACM) 100 SF

1001 Grand Total