BASE-SchedulePrices_W912C320B0001_RoofRepairs_20200306.xlsx

XLSX spreadsheet 41 KB Posted

Attached to
Roof Inspection, Repairs and Maintenance at Fort Buchanan, Puerto Rico.
Solicitation number
W912C320B0001
Issued by

View the file

Other files

File Type Posted
BidAbstract_W912C320B0001_RoofRepairs_20200514.pdf PDF
Amend0007_W912C320B0001_RoofRepairs20200506.pdf PDF
Amend0006_W912C320B0001_RoofRepairs20200428.pdf PDF
Amend0005_W912C320B0001_RoofRepairs20200421.pdf PDF
Amend0004_W912C320B0001_RoofRepairs20200409.pdf PDF
Amend0003_W912C320B0001_RoofRepairs20200318.pdf PDF
Photo12Amend0002_W912C320B0001_RoofRepairs20200316.pdf PDF
Amend0002_W912C320B0001_RoofRepairs20200316.pdf PDF
Photo2Amend0002_W912C320B0001_RoofRepairs20200316.pdf PDF
Photo9Amend0002_W912C320B0001_RoofRepairs20200316.pdf PDF
Photo3Amend0002_W912C320B0001_RoofRepairs20200316.pdf PDF
Photo8Amend0002_W912C320B0001_RoofRepairs20200316.pdf PDF
Photo11Amend0002_W912C320B0001_RoofRepairs20200316.pdf PDF
Photo4Amend0002_W912C320B0001_RoofRepairs20200316.pdf PDF
Photo7Amend0002_W912C320B0001_RoofRepairs20200316.pdf PDF
Photo10Amend0002_W912C320B0001_RoofRepairs20200316.pdf PDF
Photo5Amend0002_W912C320B0001_RoofRepairs20200316.pdf PDF
Photo1Amend0002_W912C320B0001_RoofRepairs20200316.pdf PDF
Photo6Amend0002_W912C320B0001_RoofRepairs20200316.pdf PDF
Amend0001_W912C320B0001_RoofRepairs20200309.pdf PDF
FIRST-SchedulePrices_W912C320B0001_RoofRepairs_20200306.xlsx XLSX spreadsheet
FOURTH-SchedulePrices_W912C320B0001_RoofRepairs_20200306.xlsx XLSX spreadsheet
Solicitation-W912C320B0001-RoofRepair-20200306.pdf PDF
SECOND-SchedulePrices_W912C320B0001_RoofRepairs_20200306.xlsx XLSX spreadsheet
Dwg_W912C320B0001-RoofRepair-20200306.pdf PDF
THIRD-SchedulePrices_W912C320B0001_RoofRepairs_20200306.xlsx XLSX spreadsheet
SOWSpecs_W912C320B0001-RoofRepairs-20200306.pdf PDF
Show all 27

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

BASE PERIOD

SCHEDULE OF PRICES
BASE PERIOD: IFB W912C320B0001, ROOF REPAIR INSPECTION & MAINTENANCE
ItemItem DescriptionEstimatedUnitUnit CostTotal Cost
Quantity
0001Roof Inspection Survey and Written Report with As-Built Roof Plan125,000SF
(Section 01 11 00, Para 1.2, 1.2.1, 1.2.2.a through h)
0002Provide As-Built Roof Plans125,000SF
(Section 01 11 00, Para 1.2.2)
0003Sampling & Laboratory Testing and Test Report for Asbestos Materials15EA
(Section 01 11 00, Para 1.2.2.e and Para 1.4.6)
0004Repair Concrete Roof (Plain Concrete)1,600SF
(Section 01 11 00, Para 1.4.1.a, b, c, d, e) (See Tech Specs.)
0005Repair Corrugated Metal Roof6,000SF
(Section 01 11 00, Para 1.4.2.a, b, c) (See Tech Specs.)
0006Remove and Dispose Corrugated Metal Roof Panels, GA 24540SF
(Section 01 11 00, Para 1.4.2.e) (See Tech Specs.)
0007Install Corrugated Metal Roof Panels, GA 24540SF
(Section 01 11 00, Para 1.4.2.e) (See Tech Specs.)
0008Remove and Dispose Corrugated Metal Roof Panels, GA 26540SF
(Section 01 11 00, Para 1.4.2.e) (See Tech Specs.)
0009Install Corrugated Metal Roof Panels, GA 26540SF
(Section 01 11 00, Para 1.4.2.e) (See Tech Specs.)
0010Repair Corrugated Metal Roof: Painting5,500SF
(Section 01 11 00, Para 1.4.2. d, f, and g)
0011Repair Modified Bitumen (Insulation, and 3-ply w/cold adhesvie)300SF
(See Tech Specs.)
0012Repair Modified Bitumen (Insulation, and 3-ply w/torched seams)300SF
(See Tech Specs.)
0013Repair Modified Bitumen (Insulation, and 2-ply w/cold300SF
adhesive or torched seams) (See Tech Specs.)
0014Repair Light weight Concrete insulation, Lt weight1,000SF
cellular roof fill, Port & Cem. 2 inch thick average and foaming agent
(See Tech Specs.)
0015Remove and Dispose Light weight Concrete insulation, Lt weight1,000SF
cellular roof fill, Port & Cem. 2 inch thick average and foaming agent
(See Tech Specs.)
0016Install Light weight Concrete insulation, Lt weight1,000SF
cellular roof fill, Port & Cem. 2 inch thick average and foaming agent
(See Tech Specs.)
0017Repair Light weight Concrete insulation, Lt weight1,000SF
cellular roof fill, Port & Cem. 4 inch thick average and foaming agent
(See Tech Specs.)
0018Remove and Dispose Light weight Concrete insulation, Lt weight1,000SF
cellular roof fill, Port & Cem. 4 inch thick average and foaming agent
(See Tech Specs.)
0019Install Light weight Concrete insulation, Lt weight1,000SF
cellular roof fill, Port & Cem. 4 inch thick average and foaming agent
(See Tech Specs.)

0020 Remove and Dispose Insulation 2-inch Average Thick (See Tech Specs.) 2,000 SF

0021 Install Insulation 2-inch Average Thick (See Tech Specs.) 2,000 SF

0022 Remove and Dispose E.P.D.M with Insulation (See Tech Specs.) 2,500 SF

0023 Install E.P.D.M with Insulation (See Tech Specs.) 2,500 SF

0024 Remove and Dispose Built-up Roofing (Insulation 3-ply, Hot Adhesive and Gravel) (See Tech Specs.) 15,000 SF

0025Install Built-up Roofing (Insulation 3-ply, Hot Adhesive and Gravel)15,000SF
(See Tech Specs.)
0026Repair Single Ply with adhesive or Asphalt Moppping1,500SF
(See Tech Specs.)

0027 Repair Insulation and Hot Asphalt Plies 1,000 SF

0028Remove and Dispose Standing Seam Metal Over Insulation500SF
(Section 07 61 13)
0029Install Standing Seam Metal Over Insulation500SF
(Section 07 61 13)
0030Remove and Dispose Asphalt Shingles over Insulation and over500SF
standing Seam Metal Roof (See Tech Specs.)
0031Install Asphalt Shingles over Insulation and over500SF
standing Seam Metal Roof (See Tech Specs.)
0032Repair Water Proof Asphalt Coating500SF
(See Tech Specs.)
0033Repair Sprayed Polyurethane with top Silicone Coating (PUF)10,000SF
(See Tech Specs.)
0034Remove and Dispose Primer and Elastomeric Coating10,000SF
(See Tech Specs.)
0035Install Primer and Elastomeric Coating10,000SF
(See Tech Specs.)
0036Blisters Repairs for Modified Bitumen1,000SF
(Section 01 11 00, Para 1.4.3) (See Tech Specs.)
0037Blister Repairs for E.P.D.M.1,000SF
(Section 01 11 00, Para 1.4.3) (See Tech Specs.)
0038Blister Repairs for Built-up Roofing1,500SF
(Section 01 11 00, Para 1.4.3) (See Tech Specs.)
0039Blister Repairs for PUF1,500SF
(Section 01 11 00, Para 1.4.5.d and e.(1) through (8) (See Tech Specs.)
0040PUF Minor Repairs500SF
(Section 01 11 00 , Para 1.4.5.C.(1) through (5) (See Tech Specs.)
0041PUF or Built-up Roofing Repairs w/Asbestos Mastic (ACM)500SF
(Section 01 11 00, Para 1.4.6) (See Tech Specs.)
0042PUF or Built-up Roofing Replacement w/Asbestos Mastic (ACM)7,500SF
(Section 01 11 00, Para 1.4.6) (See Tech Specs.)
0043Remove and Dispose Radiant Barrier Blanket130,000SF
Section 01 11 00, Para 1.5, 1.5.1 and 1.5.2) (See Tech Specs.)
0044Install Radiant Barrier Blanket130,000SF
Section 01 11 00, Para 1.5, 1.5.1 and 1.5.2) (See Tech Specs.)
0045Repair Cracks at Roofing Systems1,500LF
(Section 01 11 00, Para 1.4.3.e) (See Tech Specs.)
0046Correct Water Ponding Areas at Roofing Systems1,500SF
(Section 01 11 00, Para 1.4.3.d) (See Tech Specs.)
0047Maintenance for Roofing Systems130,000SF
(Section 01 11 00, Par1.9.a through c) (See Tech Specs.)

0048 Cement parging, 2 coats, waterproofed Portland cement (See Tech Specs.) 1,500 SF

0049Structural steel projects, steel surface treatments, wire brush, hand1,500SF
Sanding
0050Struct. steel projects,sprayed painting,univ primer plus1 paint at,phenolic,1,500SF
modified alkyd (See Tech Specs.)
0051Near white blast, (SSPC-10), exist coat blistered/pitted,1,500SF
9.0 #/SF (See Tech Specs.)
0052Structural steel project,pnts&prot ctg,sprayed,zinc rich primer,epoxy,1,500SF
spray,organic (See Tech Specs.)

0053 Strl st projs, pnts & prot ctg, sprayed, epoxy, intmd or topcoat (See Tech Specs.) 1,500 SF

0054Epoxy dk ctg, bitumen modified polyurethane, fld applied,1,500SF
55 mils thk (See Tech Specs.)

0055 Remove and Dispose Open web joist girders, average (See Tech Specs.) 1 TON

0056 Install Open web joist girders, average (See Tech Specs.) 1 TON

0057 Remove and Dispose Lightweight framing, angle, field fab, 3" x 3" x 3/8" (See Tech Specs.) 100 LF

0058Install Lightweight framing, angle, field fab, 3" x 3" x 3/8" (See Tech100LF
Specs.)

0059 Remove and Dispose Framing, joists, 2" x 12" (See Tech Specs.) 100 LF

0060 Install Framing, joists, 2" x 12" (See Tech Specs.) 100 LF

0061 Remove and Dispose Framing, joists, 2" x 4" (See Tech Specs.) 100 LF

0062 Install Framing, joists, 2" x 4" (See Tech Specs.) 100 LF

0063 Remove and Dispose Framing, joists, 2" x 6" (See Tech Specs.) 100 LF

0064 Install Framing, joists, 2" x 6" (See Tech Specs.) 100 LF

0065 Remove and Dispose Framing, joists, 2" x 8" (See Tech Specs.) 100 LF

0066 Install Framing, joists, 2" x 8" (See Tech Specs.) 100 LF

0067 Remove and Dispose Framing, joists, 2" x 10" (See Tech Specs.) 100 LF

0068 Install Framing, joists, 2" x 10" (See Tech Specs.) 100 LF

0069 Remove and Dispose Framing, roofs, fascia boards, 2" x 8" (See Tech Specs.) 100 LF

0070 Install Framing, roofs, fascia boards, 2" x 8" (See Tech Specs.) 100 LF

0071 Remove and Dispose Framing, roofs, rafters, to 4 in 12 pitch, 2" x 8" (See Tech Specs.) 100 LF

0072 Install Framing, roofs, rafters, to 4 in 12 pitch, 2" x 8" (See Tech Specs.) 100 LF

0073 Remove and Dispose Framing, roofs, rafters, to 4 in 12 pitch, 2" x 6" (See Tech Specs.) 100 LF

0074 Install Framing, roofs, rafters, to 4 in 12 pitch, 2" x 6" (See Tech Specs.) 100 LF

0075 Remove and Dispose Framing, roofs, ridge board, #2 or better, 1" x 8" (See Tech Specs.) 100 LF

0076 Install Framing, roofs, ridge board, #2 or better, 1" x 8" (See Tech Specs.) 100 LF

0077 Remove and Dispose Framing, roofs, roof cants, split, 4" x 4" (See Tech Specs.) 100 LF

0078 Install Framing, roofs, roof cants, split, 4" x 4" (See Tech Specs.) 100 LF

0079 Remove and Dispose Framing, miscellaneous, nailers, treated, wood construction, 2" x 6" (See Tech Specs.) 100 LF

0080Install Framing, miscellaneous, nailers, treated, wood construction,100LF
2" x 6" (See Tech Specs.)

0081 Remove and Dispose Exp jt,butyl or nprn ctr W/foam insul,alum,.032"thk for opng to 2-1/2" (See Tech Specs.) 200 LF

0082Install Exp jt,butyl or nprn ctr W/foam insul,alum,.032"thk for opng to200LF
2-1/2" (See Tech Specs.)

0083 Remove and Dispose Exp jt, butyl or nprn ctr W/foam insul, alum, for jt opngs to 3-1/2" (See Tech Specs.) 200 LF

0084Install Exp jt, butyl or nprn ctr W/foam insul, alum, for jt opngs to200LF
3-1/2" (See Tech Specs.)

0085 Remove and Dispose Expansion joint, roof joint with extruded aluminum cover, 2" (See Tech Specs.) 100 LF

0086 Install Expansion joint, roof joint with extruded aluminum cover, 2" (See Tech Specs.) 100 LF

0087 Remove and Dispose Expansion joint, roof to wall joint with extruded aluminum cover (See Tech Specs.) 100 LF

0088Install Expansion joint, roof to wall joint with extruded aluminum cover100LF
(See Tech Specs.)
0089Remove and Dispose Expansion joint, wall joint, closed cell foam on PVC100LF
cover, 9" wide (See Tech Specs.)
0090Remove and Dispose Expansion joint, wall joint, closed cell foam on PVC100LF
cover, 9" wide (See Tech Specs.)

0091 Remove and Dispose Expansion jt, neoprene, dbl-seal type with thick center, 4-1/2" wide (See Tech Specs.) 100 LF

0092Install Expansion jt, neoprene, dbl-seal type with thick center,100LF
4-1/2" wide (See Tech Specs.)

0093 Cleaning high pressure water only, minimum (See Tech Specs.) 150,000 SF

0094 Remove and Dispose Sheathing, with boards, 1" x 12" boards, laid diagonal (See Tech Specs.) 100 SF

0095 Install Sheathing, with boards, 1" x 12" boards, laid diagonal (See Tech Specs.) 100 SF

0096 Remove and Dispose Sheathing, plywood on roof, CDX, 5/8" thick (See Tech Specs.) 100 SF

0097 Install Sheathing, plywood on roof, CDX, 5/8" thick (See Tech Specs.) 100 SF

0098 Remove and Dispose Steel roofing, on steel frame, corrugated or ribbed, galv, 24 ga (See Tech Specs.) 100 SF

0099Install Steel roofing, on steel frame, corrugated or ribbed, galv, 24 ga100SF
(See Tech Specs.)
0100Remove and Dispose Steel roofing, on steel frame, corrugated or ribbed, galv, 26 ga100SF
(See Tech Specs.)
0101Install Steel roofing, on steel frame, corrugated or ribbed, galv, 26 ga100SF
(See Tech Specs.)

0102 Remove and Dispose roof flat profile, 1-3/4" stand. seams, 12" w, stand. fin. 24 ga. (See Tech Specs.) 100 SF

0103Install Steel roof flat profile, 1-3/4" stand. seams, 12" w, stand. fin. 24 ga.100SF
(See Tech Specs.)

0104 Remove and Dispose Aluminum roofing, corrugated, painted, .032" thick (See Tech Specs.) 100 SF

0105Install Aluminum roofing, corrugated, painted, .032" thick (See Tech100SF
Specs.)

0106 Remove and Dispose Asphalt shingles, #15 felt underlayment (See Tech Specs.) 100 SF

0107 Install Asphalt shingles, #15 felt underlayment (See Tech Specs.) 100 SF

0108 Remove and Dispose Asphalt shingles, std strip shingles, inorganic, class A, 210-235 lb/sq (See Tech Specs.) 100 SF

0109Install Asphalt shingles, std strip shingles, inorganic, class A,100SF
210-235 lb/sq (See Tech Specs.)

0110 Remove and Dispose Steel roofing, ridge, galvanized, 20" wide (See Tech Specs.) 100 LF

0111 Install Steel roofing, ridge, galvanized, 20" wide (See Tech Specs.) 100 LF

0112 Remove and Dispose Fascia, aluminum, .032" thick, colored, NO furring included (See Tech Specs.) 100 SF

0113Install Fascia, aluminum, .032" thick, colored, NO furring included100SF
(See Tech Specs.)
0114Remove and Dispose Fascia, steel, galv and enameled, stock, NO furring,100SF
long panels (See Tech Specs.)
0115Install Fascia, steel, galv and enameled, stock, NO furring,100SF
long panels (See Tech Specs.)

0116 Remove and Dispose Gutters, aluminum, 5" box type, enameled (See Tech Specs.) 200 LF

0117 Install Gutters, aluminum, 5" box type, enameled (See Tech Specs.) 200 LF

0118 Remove and Dispose Gutters, alum, 5" x 6" comb fascia & gutter, .032" thick, enameled (See Tech Specs.) 200 LF

0119Install Gutters, alum, 5" x 6" comb fascia & gutter, .032" thick,200LF
enameled (See Tech Specs.)
0120Remove and Dispose Gutters, steel, galv, half round or box, 28 ga, 5"250LF
wide, enameled (See Tech Specs.)
0121Install Gutters, steel, galv, half round or box, 28 ga, 5" wide,250LF
enameled (See Tech Specs.)

0122 Remove and Dispose Gravel stop, galv steel, 6" face height (See Tech Specs.) 250 LF

0123 Install Gravel stop, galv steel, 6" face height (See Tech Specs.) 250 LF

0124 Remove and Dispose Gravel stop, aluminum, .050" thick, 6" height, painted (See Tech Specs.) 250 LF

0125 Install Gravel stop, aluminum, .050" thick, 6" height, painted (See Tech Specs.) 250 LF

0126 Remove and Dispose Gravel Gravel stop, aluminum, .050" thick, 8" height, painted (See Tech Specs.) 250 LF

0127 Install Gravel stop, aluminum, .050" thick, 8" height, painted (See Tech Specs.) 250 LF

0128 Remove and Dispose Gravel Gravel Gutters, aluminum, 5" box type, .032" thick, plain (See Tech Specs.) 200 LF

0129Install Gutters, aluminum, 5" box type, .032" thick, plain (See Tech200LF
Specs.)

0130 Remove and Dispose Gutters, steel, galv, half round or box, 28 ga, 5" wide, plain (See Tech Specs.) 200 LF

0131 Install Gutters, steel, galv, half round or box, 28 ga, 5" wide, plain (See Tech Specs.) 200 LF

0132 Remove and Dispose Gravel stop, aluminum, .050" thick, 6" height, duranodic finish (See Tech Specs.) 200 LF

0133Install Gravel stop, aluminum, .050" thick, 6" height, duranodic finish200LF
(See Tech Specs.)

0134 Remove and Dispose Gravel stop, aluminum, .050" thick, 8" height, duranodic finish (See Tech Specs.) 200 LF

0135Install Gravel stop, aluminum, .050" thick, 8" height, duranodic finish200LF
(See Tech Specs.)

0136 Remove and Dispose Downspouts, aluminum 3" x 4", .024" thick, enameled (See Tech Specs.) 100 LF

0137 Install Downspouts, aluminum 3" x 4", .024" thick, enameled (See Tech Specs.) 100 LF

0138Remove and Dispose Downspouts, steel, rectangular, plain, 28 ga, galvanized,100LF
3" x 4" (See Tech Specs.)
0139Install Downspouts, steel, rectangular, plain, 28 ga, galvanized,100LF
3" x 4" (See Tech Specs.)
0140Remove and Dispose Downspouts, steel, rect, epoxy painted, 24 ga, corrugated,100LF
3" x 4" (See Tech Specs.)
0141Install Downspouts, steel, rect, epoxy painted, 24 ga, corrugated,100LF
3" x 4" (See Tech Specs.)

0142 Remove and Dispose Drip edge, aluminum, .016" thick, 5" wide, mill finish (See Tech Specs.) 100 LF

0143 Install Drip edge, aluminum, .016" thick, 5" wide, mill finish (See Tech Specs.) 100 LF

0144 Remove and Dispose and Dispose Drip edge, aluminum, .016" thick, 5" wide, white finish (See Tech Specs.) 100 LF

0145 Install Drip edge, aluminum, .016" thick, 5" wide, white finish (See Tech Specs.) 100 LF

0146 Remove and Dispose Drip edge, galvanized, 5" wide, mill finish (See Tech Specs.) 100 LF

0147 Install Drip edge, galvanized, 5" wide, mill finish (See Tech Specs.) 100 LF

0148 Remove and Dispose Elbows, aluminum, 3" x 4", .025" thick, embossed (See Tech Specs.) 100 EA

0149Install Elbows, aluminum, 3" x 4", .025" thick, embossed (See Tech100EA
Specs.)

0150 Remove and Dispose Elbows, aluminum, 3" x 4", .025" thick, enameled (See Tech Specs.) 100 EA

0151 Install Elbows, aluminum, 3" x 4", .025" thick, enameled (See Tech Specs.) 100 EA

0152 Remove and Dispose Flashing, aluminum, mill finish, .032" thick (See Tech Specs.) 100 SF

0153 Install Flashing, aluminum, mill finish, .032" thick (See Tech Specs.) 100 SF

0154 Remove and Dispose Vent flashing, aluminum with lead ring, 2" pipe (See Tech Specs.) 50 EA

0155 Install Vent flashing, aluminum with lead ring, 2" pipe (See Tech Specs.) 50 EA

0156 Remove and Dispose Vent flashing, aluminum with lead ring, 3" pipe (See Tech Specs.) 50 EA

0157 Install Vent flashing, aluminum with lead ring, 3" pipe (See Tech Specs.) 50 EA

0158 Remove and Dispose Vent flashing, aluminum with lead ring, 4" pipe (See Tech Specs.) 50 EA

0159 Install Vent flashing, aluminum with lead ring, 4" pipe (See Tech Specs.) 50 EA

0160 Remove and Dispose Vent flashing, aluminum with lead ring, 1-1/2" pipe (See Tech Specs.) 50 EA

0161Install Vent flashing, aluminum with lead ring, 1-1/2" pipe (See Tech50EA
Specs.)

0162 Remove and Dispose Reglet, counter flashing for above, 12" wide, .032" aluminum (See Tech Specs.) 100 LF

0163Install Reglet, counter flashing for above, 12" wide, .032" aluminum100LF
(See Tech Specs.)
0164Remove and Dispose Roof vents, mushroom for built-up roofs, PVC, 6"50EA
high

0165 Install Roof vents, mushroom for built-up roofs, PVC, 6" high 50 EA

0166 Remove and Dispose Vents, one-way, aluminum (See Tech Specs.) 50 EA

0167 Install Vents, one-way, aluminum (See Tech Specs.) 50 EA

0168 Remove and Dispose Drains-scppr flr, oblique strn-CI, 6"x7" top, 2", 3"&4" pipe size (See Tech Specs.) 50 EA

0169Install Drains-scppr flr, oblique strn-CI, 6"x7" top, 2", 3"&4" pipe size50EA
(See Tech Specs.)
0170Remove and Dispose Drains, roof, flat metal deck, C.I. body, 12" C.I.50EA
dome, 3" pipe size (See Tech Specs.)
0171Install Drains, roof, flat metal deck, C.I. body, 12" C.I. dome,50EA
3" pipe size (See Tech Specs.)

0172 Remove and Dispose Drains, roof, flat mtl deck, galvanized body, 12"CI dome, 6" pipe (See Tech Specs.) 50 EA

0173Install Drains, roof, flat mtl deck, galvanized body, 12"CI dome, 6" pipe50EA
(See Tech Specs.)

0174 Remove and Dispose Drains, cornice, C.I., 45< or 90< outlet, 3" and 4" pipe size (See Tech Specs.) 50 EA

0175Install Drains, cornice, C.I., 45< or 90< outlet, 3" and 4" pipe size50EA
(See Tech Specs.)

0176 Remove and Dispose Drains, cornice, C.I., for galvanized body, 3" and 4" pipe size (See Tech Specs.) 50 EA

0177Install Drains, cornice, C.I., for galvanized body, 3" and 4" pipe size50EA
(See Tech Specs.)

0178 Remove and Dispose Elastomeric rfg,poly spray-on W/20mil silicone rbr ctg, 3"thk,r21,min (See Tech Specs.) 2,000 SF

0179Install Elastomeric rfg,poly spray-on W/20mil silicone rbr ctg ,2,000SF
3"thk,r21,min (See Tech Specs.)

0180 Remove and Dispose Built-up rfg,asph fl CT W/gvl,ctd gl base sht,3ply gl,nailable dk (See Tech Specs.) 5,500 SF

0181Install Built-up rfg,asph fl CT W/gvl,ctd gl base sht,3ply gl,nailable dk5,500SF
(See Tech Specs.)
0182Remove and Dispose Built-up rfg,asph fl CT W/gvl,ctd gl base sht,4ply gl5,500SF
fbr felt,mopped
0183Install Built-up rfg,asph fl CT W/gvl,ctd gl base sht,4ply gl fbr felt,5,500SF
mopped

0184 Remove and Dispose Cants, 4" x 4" treated timber, cut diagonally (See Tech Specs.) 200 LF

0185 Install Cants, 4" x 4" treated timber, cut diagonally (See Tech Specs.) 200 LF

0186 Remove and Dispose B247Single-ply membrane, EPDM, 60 mil, 0.40 PS, fully adhered w/adhesive, w/4" seam tape (See Tech Specs.) 5,500 SF

0187Install B247Single-ply membrane, EPDM, 60 mil, 0.40 PS, fully5,500SF
adhered w/adhesive, w/4" seam tape (See Tech Specs.)
0188Remove and Dispose Mod bit rfng, SBS mod, gran surf cap sheet, poly rein, mppd,5,500SF
160 mils w/base sheet, #15 Glass Fiber Felt fully mopped to
deck w/asphalt primer (See Tech Specs.)
0189Install Mod bit rfng, SBS mod, gran surf cap sheet, poly rein, mppd,5,500SF
160 mils w/base sheet, #15 Glass Fiber Felt fully mopped to
deck w/asphalt primer (See Tech Specs.)
0190Remove and Dispose Mod bit, SBS mod, smooth surf cap sheet, glass fiber rein, mppd, 160 mils w/base sheet, #15 Glass Fiber Felt fully5,500SF
mopped to deck w/asphalt primer (See Tech Specs.)
0191Install Mod bit, SBS mod, smooth surf cap sheet, glass fiber rein, mppd,5,500SF
160 mils w/base sheet, #15 Glass Fiber Felt fully mopped to
deck w/asphalt primer (See Tech Specs.)
0192Remove and Dispose Mod bit, APP mod, gran surface cap sheet, poly5,500SF
rein, torched, 180 mils w/base sheet, #15 Glass Fiber Felt fully mopped to
deck w/asphalt primer (See Tech Specs.)
0193Install Mod bit, APP mod, gran surface cap sheet, poly rein,5,500SF
torched, 180 mils w/base sheet, #15 Glass Fiber Felt fully mopped to
deck w/asphalt primer (See Tech Specs.)
0194Remove and Dispose Mod bit, APP mod, smooth surf cap sheet, poly rein, torched, 160 mils w/base sheet, #15 Glass Fiber Felt fully mopped to5,500SF
deck w/asphalt primer (See Tech Specs.)
0195Install Mod bit, APP mod, smooth surf cap sheet, poly rein, torched,5,500SF
160 mils w/base sheet, #15 Glass Fiber Felt fully mopped to
deck w/asphalt primer (See Tech Specs.)

0196 Remove and Dispose Roof coatings, asphalt primer, 5 gallon (See Tech Specs.) 30,000 SF

0197 Install Roof coatings, asphalt primer, 5 gallon (See Tech Specs.) 30,000 SF

0198 Remove and Dispose Bituminous asphalt coating, with fibers, troweled on, 1/2" thick (See Tech Specs.) 5,000 SF

0199Install Bituminous asphalt coating, with fibers, troweled on, 1/2" thick5,000SF
(See Tech Specs.)

0200 Remove and DisposeBuilt-up rfg,asph fl CT,ctd gl fbr base sht,3 plies,on nailable dks (See Tech Specs.) 5,000 SF

0201Install Built-up rfg,asph fl CT,ctd gl fbr base sht,3 plies,on nailable dks5,000SF
(See Tech Specs.)

0202 Remove and Dispose Built-up rfg,asph fl CT,ctd gl fbr base sht,4ply gl fbr felt,mopped (See Tech Specs.) 5,000 SF

0203Install Built-up rfg,asph fl CT,ctd gl fbr base sht,4ply gl fbr felt,mopped5,000SF
(See Tech Specs.)

0204 Remove and Dispose Rubber coating, silicone or stearate, sprayed on CMU, 2 coats (See Tech Specs.) 5,000 SF

0205Install Rubber coating, silicone or stearate, sprayed on CMU, 2 coats5,000SF
(See Tech Specs.)

0206 Remove and Dispose Pitch Pockets, side extenders, 6" (See Tech Specs.) 50 EA

0207 Install Pitch Pockets, side extenders, 6" (See Tech Specs.) 50 EA

0208 Remove and Dispose Pitch Pockets, adjustable, 4" to 7", welded corners, 4" deep (See Tech Specs.) 50 EA

0209Install Pitch Pockets, adjustable, 4" to 7", welded corners, 4" deep50EA
(See Tech Specs.)

0210 Remove and Dispose Walkway for BUR, asph impregnated, 3' x 3' x 3/4" thk (See Tech Specs.) 1,000 SF

0211 Install Walkway for BUR, asph impregnated, 3' x 3' x 3/4" thk (See Tech Specs.) 1,000 SF

0212 Remove and Dispose Caulking & sealants, polyurethane, 1 or 2 component, bulk (See Tech Specs.) 500 LF

0213Install Caulking & sealants, polyurethane, 1 or 2 component, bulk500LF
(See Tech Specs.)

0214 Remove and Dispose Caulking and sealants, silicone rubber, cartridges (See Tech Specs.) 500 LF

0215Install Caulking and sealants, silicone rubber, cartridges (See Tech500LF
Specs.)

0216 Remove and Dispose Caulking and sealants, resin epoxy coating, 2 component, heavy duty (See Tech Specs.) 500 LF

0217Install Caulking and sealants, resin epoxy coating, 2 component, heavy500LF
duty (See Tech Specs.)

0218 Remove and Dispose Caulking and sealants, neoprene gaskets, closed cell, 1/4" x 3/4" (See Tech Specs.) 500 LF

0219Install Caulking and sealants, neoprene gaskets, closed cell, 1/4" x 3/4"500LF
(See Tech Specs.)

0220 Remove and Dispose Framing, miscellaneous, nailers, treated, wood construction, 2" x 6" (See Tech Specs.) 500 LF

0221Install Framing, miscellaneous, nailers, treated, wood construction, 2" x 6"500LF
(See Tech Specs.)

0222 Remove and Dispose Framing, miscellaneous, nailers, treated, wood construction, 2" x 4" (See Tech Specs.) 500 LF

0223Install Framing, miscellaneous, nailers, treated, wood construction, 2" x 4"500LF
(See Tech Specs.)

0224 Remove and Dispose Framing, miscellaneous, nailers, treated, wood construction, 2" x 8" (See Tech Specs.) 500 LF

0225Install Framing, miscellaneous, nailers, treated, wood construction, 2" x 8"500LF
(See Tech Specs.)

0226 Remove and Dispose Roof deck insul, polyisocyanurate, 2#/CF density, 2" thk R14.29 (See Tech Specs.) 10,200 SF

0227Install Roof deck insul, polyisocyanurate, 2#/CF density, 2" thk R14.2910,200SF
(See Tech Specs.)
0228Remove and Dispose Roof deck insulation, polyisocyanurate 2#/CF10,200SF
density, tapered for drainage (See Tech Specs.)
0229Install Roof deck insulation, polyisocyanurate 2#/CF density,10,200SF
tapered for drainage (See Tech Specs.)

0230 Remove and Dispose Roof deck insulation, expanded polystyrene, 2" thick R7.69 (See Tech Specs.) 10,200 SF

0231Install Roof deck insulation, expanded polystyrene, 2" thick R7.6910,200SF
(See Tech Specs.)

0232 Remove and Dispose Roof deck insulation, expanded polystyrene, tapered for drainage (See Tech Specs.) 1,500 SF

0233Install Roof deck insulation, expanded polystyrene, tapered for drainage1,500SF
(See Tech Specs.)
0234Remove and Dispose Roof deck insul., extruded polystyrene, 60 PSI10,200SF
comp. strength, 2" thick R10 (See Tech Specs.)
0235Install Roof deck insul., extruded polystyrene, 60 PSI comp.10,200SF
strength, 2" thick R10 (See Tech Specs.)

0236 Remove and Dispose Roof deck insul., extruded polystyrene, 60 PSI comp. strgth., tapered (See Tech Specs.) 10,200 SF

0237Install Roof deck insul., extruded polystyrene, 60 PSI comp. strgth.,10,200SF
tapered (See Tech Specs.)

0238 Remove and Dispose Roof hatch, 2'-6" x 3', w/curb, 1" fbgls insul, galv stl curb/cover (See Tech Specs.) 2 EA

0239Install Roof hatch, 2'-6" x 3', w/curb, 1" fbgls insul, galv stl curb/cover2EA
(See Tech Specs.)

0240 Remove and Dispose Skylight, insulated safety glass with aluminum frame (See Tech Specs.) 500 SF

0241 Install Skylight, insulated safety glass with aluminum frame (See Tech Specs.) 500 SF

0242 Remove and Dispose Ladder, steel, 20" wide, bolted to concrete, with cage (See Tech Specs.) 250 VLF

0243 Install Ladder, steel, 20" wide, bolted to concrete, with cage (See Tech Specs.) 500 VLF

0244 Remove and DisposeLadder, steel, 20" wide, bolted to concrete, w/o cage (See Tech Specs.) 250 VLF

0245 Install Ladder, steel, 20" wide, bolted to concrete, w/o cage (See Tech Specs.) 600 VLF

0246 Replace Insulation/finish syst, field applied, 1 inch (See Tech Specs.) 2,500 SF

0247 Replace Insulation/finish syst, field applied, 2 inch (See Tech Specs.) 500 SF

0248 Replace Insulation/finish syst, field applied, 3 inch (See Tech Specs.) 500 SF

0249 Replace Ductwork, galv steel, 500-1000 lb, 12"-14"h, 18"w (See Tech Specs.) 100 LB

0250 Replace Ductwork, galv steel, 500-1000 lb, 12"-14"h, 24"w (See Tech Specs.) 100 LB

0251 Replace Ductwork, galv steel, 500-1000 lb, 12"-14"h, 48"w (See Tech Specs.) 100 LB

0252 Pipe, copper, 3/8" dia., type K (See Tech Specs.) 200 LF

0253 Pipe insulation, 3/8" copper pipe, rubber tubing (See Tech Specs.) 200 LF

0254 Vent and Pipe Replacement, PVC schedule 40, 2" dia. (See Tech Specs.) 25 LF

0255 Vent and Pipe Replacement, PVC schedule 40, 3" dia. (See Tech Specs.) 25 LF

0256 Vent and Pipe Replacement, PVC schedule 40, 4" dia. (See Tech Specs.) 25 LF

0257 HVAC demo, Mech equipment (See Tech Specs.) 6,000 LBS

0258 Air cooled condenser, 2 tons, reinstallation (See Tech Specs.) 30 EA

0259 Air cooled condenser, 16 tons,reinstallation (See Tech Specs.) 30 EA

0260 Roof top unit, 7.5 tons, single zone, reinstallation (See Tech Specs.) 30 EA

0261 Replace Wire, 600 volt, type THW, copper, stranded, #12 (See Tech Specs.) 1,000 LF

0262 Replace Wire, 600 volt, type THW, copper, solid, #12 (See Tech Specs.) 1,000 LF

0263 Replace Wire, 600 volt, type THW, copper, stranded, #10 (See Tech Specs.) 1,000 LF

0264 Replace Wire, 600 volt, type THW, copper, solid, #10 (See Tech Specs.) 1,000 LF

0265Replace Wire, 600 volt, type THW, copper, stranded, #8 (See Tech1,000LF
Specs.)
0266Replace Wire, 600 volt, type THW, copper, stranded, #6 (See Tech1,000LF
Specs.)

0267 ReplaceWire, 600 volt, type THW, copper, stranded, #4 (See Tech Specs.) 1,000 LF

0268Replace Wire, 600 volt, type THW, copper, stranded, #3 (See Tech1,000LF
Specs.)
0269Replace Wire, 600 volt, type THW, copper, stranded, #2 (See Tech1,000LF
Specs.)
0270Replace Wire, 600 volt, type THW, copper, stranded, #1 (See Tech1,000LF
Specs.)

0271 Replace Wire, 600 volt, type THWN-THHN, copper, stranded, #12 (See Tech Specs.) 1,000 LF

0272 Replace Wire, 600 volt, type THWN-THHN, copper, solid, #12 (See Tech Specs.) 1,000 LF

0273 Replace Wire, 600 volt, type THWN-THHN, copper, stranded, #10 (See Tech Specs.) 1,000 LF

0274 Replace Wire, 600 volt, type THWN-THHN, copper, solid, #10 (See Tech Specs.) 1,000 LF

0275 Replace Wire, 600 volt, type THWN-THHN, copper, stranded, #8 (See Tech Specs.) 1,000 LF

0276 Replace Wire, 600 volt, type THWN-THHN, copper, stranded, #6 (See Tech Specs.) 1,000 LF

0277 Replace Wire, 600 volt, type THWN-THHN, copper, stranded, #4 (See Tech Specs.) 1,000 LF

0278 Replace Cond to 15' H,incl 2 termn,2 elb&11 bm CLP per 100',galv stl,1/2" dia (See Tech Specs.) 550 LF

0279 Replace Cond to 15' H,incl 2 termn,2 elb&11 bm CLP per 100',galv stl,3/4" dia (See Tech Specs.) 550 LF

0280Replace Cond to 15' H,incl 2 termn,2 elb&11 bm CLP per 100',galv stl,1"550LF
dia (See Tech Specs.)

0281 Replace Cond to 15' H,incl 2 termn,2 elb&11 bm CLP per 100',galv stl,1-1/4"dia (See Tech Specs.) 550 LF

0282 Replace Cond to 15' H,incl 2 termn,2 elb&11 bm CLP per 100',galv stl,1-1/2"dia (See Tech Specs.) 550 LF

0283Replace Cond to 15' H,incl 2 termn,2 elb&11 bm CLP per 100',galv stl,2"550LF
dia (See Tech Specs.)

0284 Replace Cond to 15' H,incl 2 termn,2 elb&11 bm CLP per 100',galv stl,2-1/2"dia (See Tech Specs.) 1,500 LF

0285Replace Cond to 15' H,incl 2 termn,2 elb&11 bm CLP per 100',galv stl,3"1,500LF
dia (See Tech Specs.)

0286 Replace Cond to 15' H,incl 2 termn,2 elb&11 bm CLP per 100',galv stl,3-1/2"dia (See Tech Specs.) 1,500 LF

0287Relace Cond to 15' H,incl 2 termn,2 elb&11 bm CLP per 100',galv stl,4"1,500LF
dia (See Tech Specs.)

0288 Replace Safety switches, heavy duty, 240 volt, 3 pole NEMA 1 fusible, 30 amp (See Tech Specs.) 15 EA

0289 Replace Safety switches, heavy duty, 240 volt, 3 pole NEMA 1 fusible, 60 amp (See Tech Specs.) 15 EA

0290 Replace Safety switches, heavy duty, 240 volt, 3 pole NEMA 1 fusible, 100 amp (See Tech Specs.) 15 EA

0291Replace Wire, 600 volt, type THW, copper, stranded, 1/0 (See Tech650LF
Specs.)
0292Replace Wire, 600 volt, type THW, copper, stranded, 2/0 (See Tech650LF
Specs.)
0293Replace Wire, 600 volt, type THW, copper, stranded, 3/0 (See Tech650LF
Specs.)
0294Replace Wire, 600 volt, type THW, copper, stranded, 4/0 (See Tech650LF
Specs.)

0295 Remove & dispose PUF or Built-up Roofing w/Asbestos Mastic (ACM) 100 SF

0001 Grand Total

File details come from the government source that posted it. Updated .