FOURTH-SchedulePrices_W912C320B0001_RoofRepairs_20200306.xlsx

XLSX spreadsheet 40 KB Posted

Attached to
Roof Inspection, Repairs and Maintenance at Fort Buchanan, Puerto Rico.
Solicitation number
W912C320B0001
Issued by

View the file

Other files

File Type Posted
BidAbstract_W912C320B0001_RoofRepairs_20200514.pdf PDF
Amend0007_W912C320B0001_RoofRepairs20200506.pdf PDF
Amend0006_W912C320B0001_RoofRepairs20200428.pdf PDF
Amend0005_W912C320B0001_RoofRepairs20200421.pdf PDF
Amend0004_W912C320B0001_RoofRepairs20200409.pdf PDF
Amend0003_W912C320B0001_RoofRepairs20200318.pdf PDF
Photo12Amend0002_W912C320B0001_RoofRepairs20200316.pdf PDF
Amend0002_W912C320B0001_RoofRepairs20200316.pdf PDF
Photo2Amend0002_W912C320B0001_RoofRepairs20200316.pdf PDF
Photo9Amend0002_W912C320B0001_RoofRepairs20200316.pdf PDF
Photo3Amend0002_W912C320B0001_RoofRepairs20200316.pdf PDF
Photo8Amend0002_W912C320B0001_RoofRepairs20200316.pdf PDF
Photo11Amend0002_W912C320B0001_RoofRepairs20200316.pdf PDF
Photo4Amend0002_W912C320B0001_RoofRepairs20200316.pdf PDF
Photo7Amend0002_W912C320B0001_RoofRepairs20200316.pdf PDF
Photo10Amend0002_W912C320B0001_RoofRepairs20200316.pdf PDF
Photo5Amend0002_W912C320B0001_RoofRepairs20200316.pdf PDF
Photo1Amend0002_W912C320B0001_RoofRepairs20200316.pdf PDF
Photo6Amend0002_W912C320B0001_RoofRepairs20200316.pdf PDF
Amend0001_W912C320B0001_RoofRepairs20200309.pdf PDF
FIRST-SchedulePrices_W912C320B0001_RoofRepairs_20200306.xlsx XLSX spreadsheet
BASE-SchedulePrices_W912C320B0001_RoofRepairs_20200306.xlsx XLSX spreadsheet
Solicitation-W912C320B0001-RoofRepair-20200306.pdf PDF
SECOND-SchedulePrices_W912C320B0001_RoofRepairs_20200306.xlsx XLSX spreadsheet
Dwg_W912C320B0001-RoofRepair-20200306.pdf PDF
THIRD-SchedulePrices_W912C320B0001_RoofRepairs_20200306.xlsx XLSX spreadsheet
SOWSpecs_W912C320B0001-RoofRepairs-20200306.pdf PDF
Show all 27

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FOURTH OPTION

SCHEDULE OF PRICES
FOURTH OPTION PERIOD: IFB W912C320B0001, ROOF REPAIR INSPECTION & MAINTENANCE
ItemItem DescriptionEstimatedUnitUnit CostTotal Cost
Quantity
4001Roof Inspection Survey and Written Report with As-Built Roof Plan125,000SF
(Section 01 11 00, Para 1.2, 1.2.1, 1.2.2.a through h)
4002Provide As-Built Roof Plans125,000SF
(Section 01 11 00, Para 1.2.2)
4003Sampling & Laboratory Testing and Test Report for Asbestos Materials15EA
(Section 01 11 00, Para 1.2.2.e and Para 1.4.6)
4004Repair Concrete Roof (Plain Concrete)1,500SF
(Section 01 11 00, Para 1.4.1.a, b, c, d, e) (See Tech Specs.)
4005Repair Corrugated Metal Roof5,000SF
(Section 01 11 00, Para 1.4.2.a, b, c) (See Tech Specs.)
4006Remove and Dispose Corrugated Metal Roof Panels, GA 24520SF
(Section 01 11 00, Para 1.4.2.e) (See Tech Specs.)
4007Install Corrugated Metal Roof Panels, GA 24520SF
(Section 01 11 00, Para 1.4.2.e) (See Tech Specs.)
4008Remove and Dispose Corrugated Metal Roof Panels, GA 26520SF
(Section 01 11 00, Para 1.4.2.e) (See Tech Specs.)
4009Install Corrugated Metal Roof Panels, GA 26520SF
(Section 01 11 00, Para 1.4.2.e) (See Tech Specs.)
4010Repair Corrugated Metal Roof: Painting5,000SF
(Section 01 11 00, Para 1.4.2. d, f, and g)
4011Repair Modified Bitumen (Insulation, and 3-ply w/cold adhesvie)200SF
(See Tech Specs.)
4012Repair Modified Bitumen (Insulation, and 3-ply w/torched seams)200SF
(See Tech Specs.)
4013Repair Modified Bitumen (Insulation, and 2-ply w/cold200SF
adhesive or torched seams) (See Tech Specs.)
4014Repair Light weight Concrete insulation, Lt weight880SF
cellular roof fill, Port & Cem. 2 inch thick average and foaming agent
(See Tech Specs.)
4015Remove and Dispose Light weight Concrete insulation, Lt weight880SF
cellular roof fill, Port & Cem. 2 inch thick average and foaming agent
(See Tech Specs.)
4016Install Light weight Concrete insulation, Lt weight880SF
cellular roof fill, Port & Cem. 2 inch thick average and foaming agent
(See Tech Specs.)
4017Repair Light weight Concrete insulation, Lt weight880SF
cellular roof fill, Port & Cem. 4 inch thick average and foaming agent
(See Tech Specs.)
4018Remove and Dispose Light weight Concrete insulation, Lt weight880SF
cellular roof fill, Port & Cem. 4 inch thick average and foaming agent
(See Tech Specs.)
4019Install Light weight Concrete insulation, Lt weight880SF
cellular roof fill, Port & Cem. 4 inch thick average and foaming agent
(See Tech Specs.)
4020Remove and Dispose Insulation 2-inch Average Thick1,500SF
(See Tech Specs.)

4021 Install Insulation 2-inch Average Thick (See Tech Specs.) 1,500 SF

4022Remove and Dispose E.P.D.M with Insulation2,000SF
(See Tech Specs.)

4023 Install E.P.D.M with Insulation (See Tech Specs.) 2,000 SF

4024 Remove and Dispose Built-up Roofing (Insulation 3-ply, Hot Adhesive and Gravel) (See Tech Specs.) 5,000 SF

4025Install Built-up Roofing (Insulation 3-ply, Hot Adhesive and Gravel)5,000SF
(See Tech Specs.)
4026Repair Single Ply with adhesive or Asphalt Moppping1,040SF
(See Tech Specs.)

4027 Repair Insulation and Hot Asphalt Plies 520 SF

4028Remove and Dispose Standing Seam Metal Over Insulation260SF
(Section 07 61 13)

4029 Install Standing Seam Metal Over Insulation (Section 07 61 13) 260 SF

4030Remove and Dispose Asphalt Shingles over Insulation and over100SF
standing Seam Metal Roof (See Tech Specs.)
4031Install Asphalt Shingles over Insulation and over100SF
standing Seam Metal Roof (See Tech Specs.)
4032Repair Water Proof Asphalt Coating200SF
(See Tech Specs.)
4033Repair Sprayed Polyurethane with top Silicone Coating (PUF)5,000SF
(See Tech Specs.)
4034Remove and Dispose Primer and Elastomeric Coating5,000SF
(See Tech Specs.)
4035Install Primer and Elastomeric Coating5,000SF
(See Tech Specs.)
4036Blisters Repairs for Modified Bitumen260SF
(Section 01 11 00, Para 1.4.3) (See Tech Specs.)
4037Blister Repairs for E.P.D.M.520SF
(Section 01 11 00, Para 1.4.3) (See Tech Specs.)
4038Blister Repairs for Built-up Roofing1,040SF
(Section 01 11 00, Para 1.4.3) (See Tech Specs.)
4039Blister Repairs for PUF520SF
(Section 01 11 00, Para 1.4.5.d and e.(1) through (8) (See Tech Specs.)
4040PUF Minor Repairs260SF
(Section 01 11 00 , Para 1.4.5.C.(1) through (5) (See Tech Specs.)
4041PUF or Built-up Roofing Repairs w/Asbestos Mastic (ACM)260SF
(Section 01 11 00, Para 1.4.6) (See Tech Specs.)
4042PUF or Built-up Roofing Replacement w/Asbestos Mastic (ACM)5,200SF
(Section 01 11 00, Para 1.4.6) (See Tech Specs.)
4043Remove and Dispose Radiant Barrier Blanket130,000SF
Section 01 11 00, Para 1.5, 1.5.1 and 1.5.2) (See Tech Specs.)
4044Install Radiant Barrier Blanket130,000SF
Section 01 11 00, Para 1.5, 1.5.1 and 1.5.2) (See Tech Specs.)
4045Repair Cracks at Roofing Systems1,040LF
(Section 01 11 00, Para 1.4.3.e) (See Tech Specs.)
4046Correct Water Ponding Areas at Roofing Systems1,040SF
(Section 01 11 00, Para 1.4.3.d) (See Tech Specs.)
4047Maintenance for Roofing Systems130,000SF
(Section 01 11 00, Par1.9.a through c) (See Tech Specs.)
4048Cement parging, 2 coats, waterproofed Portland cement (See Tech1,040SF
Specs.)
4049Structural steel projects, steel surface treatments, wire brush, hand520SF
sanding (See Tech Specs.)
4050Struct. steel projects,sprayed painting,univ primer plus1 paint coat,phenolic,520SF
modified alkyd (See Tech Specs.)
4051Near white blast, (SSPC-10), exist coat blistered/pitted,520SF
9.0 #/SF (See Tech Specs.)
4052Structural steel project,pnts&prot ctg,sprayed,zinc rich primer,epoxy,520SF
spray,organic (See Tech Specs.)

4053 Strl st projs, pnts & prot ctg, sprayed, epoxy, intmd or topcoat (See Tech Specs.) 520 SF

4054Epoxy dk ctg, bitumen modified polyurethane, fld applied, 55 mils thk520SF
(See Tech Specs.)

4055 Remove and Dispose Open web joist girders, average (See Tech Specs.) 1 TON

4056 Install Open web joist girders, average (See Tech Specs.) 1 TON

4057 Remove and Dispose Lightweight framing, angle, field fab, 3" x 3" x 3/8" (See Tech Specs.) 45 LF

4058 Install Lightweight framing, angle, field fab, 3" x 3" x 3/8" (See Tech Specs.) 45 LF

4059 Remove and Dispose Framing, joists, 2" x 12" (See Tech Specs.) 55 LF

4060 Install Framing, joists, 2" x 12" (See Tech Specs.) 55 LF

4061 Remove and Dispose Framing, joists, 2" x 4" (See Tech Specs.) 55 LF

4062 Install Framing, joists, 2" x 4" (See Tech Specs.) 55 LF

4063 Remove and Dispose Framing, joists, 2" x 6" (See Tech Specs.) 55 LF

4064 Install Framing, joists, 2" x 6" (See Tech Specs.) 55 LF

4065 Remove and Dispose Framing, joists, 2" x 8" (See Tech Specs.) 55 LF

4066 Install Framing, joists, 2" x 8" (See Tech Specs.) 55 LF

4067 Remove and Dispose Framing, joists, 2" x 10" (See Tech Specs.) 55 LF

4068 Install Framing, joists, 2" x 10" (See Tech Specs.) 55 LF

4069 Remove and Dispose Framing, roofs, fascia boards, 2" x 8" (See Tech Specs.) 55 LF

4070 Install Framing, roofs, fascia boards, 2" x 8" (See Tech Specs.) 55 LF

4071 Remove and Dispose Framing, roofs, rafters, to 4 in 12 pitch, 2" x 8" (See Tech Specs.) 55 LF

4072 Install Framing, roofs, rafters, to 4 in 12 pitch, 2" x 8" (See Tech Specs.) 55 LF

4073 Remove and Dispose Framing, roofs, rafters, to 4 in 12 pitch, 2" x 6" (See Tech Specs.) 55 LF

4074 Install Framing, roofs, rafters, to 4 in 12 pitch, 2" x 6" (See Tech Specs.) 55 LF

4075 Remove and Dispose Framing, roofs, ridge board, #2 or better, 1" x 8" (See Tech Specs.) 55 LF

4076 Install Framing, roofs, ridge board, #2 or better, 1" x 8" (See Tech Specs.) 55 LF

4077 Remove and Dispose Framing, roofs, roof cants, split, 4" x 4" (See Tech Specs.) 55 LF

4078 Install Framing, roofs, roof cants, split, 4" x 4" (See Tech Specs.) 55 LF

4079Remove and Dispose Framing, miscellaneous, nailers, treated, wood construction,55LF
2" x 6" (See Tech Specs.)
4080Install Framing, miscellaneous, nailers, treated, wood construction,55LF
2" x 6" (See Tech Specs.)
4081Remove and Dispose Exp jt,butyl or nprn ctr W/foam insul,alum,.032"thk for opng to104LF
2-1/2" (See Tech Specs.)
4082Install Exp jt,butyl or nprn ctr W/foam insul,alum,.032"thk for opng to104LF
2-1/2" (See Tech Specs.)
4083Remove and Dispose Exp jt, butyl or nprn ctr W/foam insul, alum, for jt opngs to104LF
3-1/2" (See Tech Specs.)
4084Install Exp jt, butyl or nprn ctr W/foam insul, alum, for jt opngs to104LF
3-1/2" (See Tech Specs.)

4085 Remove and Dispose Expansion joint, roof joint with extruded aluminum cover, 2" (See Tech Specs.) 55 LF

4086 Install Expansion joint, roof joint with extruded aluminum cover, 2" (See Tech Specs.) 55 LF

4087 Remove and Dispose Expansion joint, roof to wall joint with extruded aluminum cover (See Tech Specs.) 55 LF

4088Install Expansion joint, roof to wall joint with extruded aluminum cover55LF
(See Tech Specs.)
4089Remove and Dispose Expansion joint, wall joint, closed cell foam on PVC55LF
cover, 9" wide (See Tech Specs.)
4090Remove and Dispose Expansion joint, wall joint, closed cell foam on PVC55LF
cover, 9" wide (See Tech Specs.)

4091 Remove and Dispose Expansion jt, neoprene, dbl-seal type with thick center, 4-1/2" wide (See Tech Specs.) 55 LF

4092Install Expansion jt, neoprene, dbl-seal type with thick center,55LF
4-1/2" wide (See Tech Specs.)

4093 Cleaning high pressure water only, minimum (See Tech Specs.) 130,000 SF

4094 Remove and Dispose Sheathing, with boards, 1" x 12" boards, laid diagonal (See Tech Specs.) 55 SF

4095 Install Sheathing, with boards, 1" x 12" boards, laid diagonal (See Tech Specs.) 55 SF

4096 Remove and Dispose Sheathing, plywood on roof, CDX, 5/8" thick (See Tech Specs.) 55 SF

4097 Install Sheathing, plywood on roof, CDX, 5/8" thick (See Tech Specs.) 55 SF

4098 Remove and Dispose Steel roofing, on steel frame, corrugated or ribbed, galv, 24 ga (See Tech Specs.) 55 SF

4099Install Steel roofing, on steel frame, corrugated or ribbed, galv, 24 ga55SF
(See Tech Specs.)

4100 Remove and Dispose Steel roofing, on steel frame, corrugated or ribbed, galv, 26 ga (See Tech Specs.) 55 SF

4101Install Steel roofing, on steel frame, corrugated or ribbed, galv, 26 ga55SF
(See Tech Specs.)

4102 Remove and Dispose roof flat profile, 1-3/4" stand. seams, 12" w, stand. fin. 24 ga. (See Tech Specs.) 55 SF

4103Install Steel roof flat profile, 1-3/4" stand. seams, 12" w, stand. fin. 24 ga.55SF
(See Tech Specs.)

4104 Remove and Dispose Aluminum roofing, corrugated, painted, .032" thick (See Tech Specs.) 55 SF

4105Install Aluminum roofing, corrugated, painted, .032" thick (See Tech55SF
Specs.)

4106 Remove and Dispose Asphalt shingles, #15 felt underlayment (See Tech Specs.) 55 SF

4107 Install Asphalt shingles, #15 felt underlayment (See Tech Specs.) 55 SF

4108 Remove and Dispose Asphalt shingles, std strip shingles, inorganic, class A, 210-235 lb/sq (See Tech Specs.) 55 SF

4109Install Asphalt shingles, std strip shingles, inorganic, class A,55SF
210-235 lb/sq (See Tech Specs.)

4110 Remove and Dispose Steel roofing, ridge, galvanized, 20" wide (See Tech Specs.) 55 LF

4111 Install Steel roofing, ridge, galvanized, 20" wide (See Tech Specs.) 55 LF

4112 Remove and Dispose Fascia, aluminum, .032" thick, colored, NO furring included (See Tech Specs.) 55 SF

4113Install Fascia, aluminum, .032" thick, colored, NO furring included55SF
(See Tech Specs.)
4114Remove and Dispose Fascia, steel, galv and enameled, stock, NO furring,55SF
long panels (See Tech Specs.)
4115Install Fascia, steel, galv and enameled, stock, NO furring,55SF
long panels (See Tech Specs.)

4116 Remove and Dispose Gutters, aluminum, 5" box type, enameled (See Tech Specs.) 160 LF

4117 Install Gutters, aluminum, 5" box type, enameled (See Tech Specs.) 160 LF

4118Remove and Dispose Gutters, alum, 5" x 6" comb fascia & gutter, .032" thick,160LF
enameled (See Tech Specs.)
4119Install Gutters, alum, 5" x 6" comb fascia & gutter, .032" thick,160LF
enameled (See Tech Specs.)
4120Remove and Dispose Gutters, steel, galv, half round or box, 28 ga, 5"104LF
wide, enameled (See Tech Specs.)
4121Install Gutters, steel, galv, half round or box, 28 ga, 5" wide,104LF
enameled (See Tech Specs.)

4122 Remove and Dispose Gravel stop, galv steel, 6" face height (See Tech Specs.) 104 LF

4123 Install Gravel stop, galv steel, 6" face height (See Tech Specs.) 104 LF

4124 Remove and Dispose Gravel stop, aluminum, .050" thick, 6" height, painted (See Tech Specs.) 104 LF

4125 Install Gravel stop, aluminum, .050" thick, 6" height, painted (See Tech Specs.) 104 LF

4126 Remove and Dispose Gravel Gravel stop, aluminum, .050" thick, 8" height, painted (See Tech Specs.) 104 LF

4127 Install Gravel stop, aluminum, .050" thick, 8" height, painted (See Tech Specs.) 104 LF

4128 Remove and Dispose Gravel Gravel Gutters, aluminum, 5" box type, .032" thick, plain (See Tech Specs.) 160 LF

4129 Install Gutters, aluminum, 5" box type, .032" thick, plain (See Tech Specs.) 160 LF

4130 Remove and Dispose Gutters, steel, galv, half round or box, 28 ga, 5" wide, plain (See Tech Specs.) 160 LF

4131 Install Gutters, steel, galv, half round or box, 28 ga, 5" wide, plain (See Tech Specs.) 160 LF

4132Remove and Dispose Gravel stop, aluminum, .050" thick, 6" height, duranodic finish104LF
(See Tech Specs.)
4133Install Gravel stop, aluminum, .050" thick, 6" height, duranodic finish104LF
(See Tech Specs.)

4134 Remove and Dispose Gravel stop, aluminum, .050" thick, 8" height, duranodic finish (See Tech Specs.) 104 LF

4135Install Gravel stop, aluminum, .050" thick, 8" height, duranodic finish104LF
(See Tech Specs.)

4136 Remove and Dispose Downspouts, aluminum 3" x 4", .024" thick, enameled (See Tech Specs.) 60 LF

4137 Install Downspouts, aluminum 3" x 4", .024" thick, enameled (See Tech Specs.) 60 LF

4138 Remove and Dispose Downspouts, steel, rectangular, plain, 28 ga, galvanized, 3" x 4" (See Tech Specs.) 60 LF

4139Install Downspouts, steel, rectangular, plain, 28 ga, galvanized,60LF
3" x 4" (See Tech Specs.)
4140Remove and Dispose Downspouts, steel, rect, epoxy painted, 24 ga, corrugated,60LF
3" x 4" (See Tech Specs.)
4141Install Downspouts, steel, rect, epoxy painted, 24 ga, corrugated,60LF
3" x 4" (See Tech Specs.)

4142 Remove and Dispose Drip edge, aluminum, .016" thick, 5" wide, mill finish (See Tech Specs.) 60 LF

4143 Install Drip edge, aluminum, .016" thick, 5" wide, mill finish (See Tech Specs.) 60 LF

4144 Remove and Dispose and Dispose Drip edge, aluminum, .016" thick, 5" wide, white finish (See Tech Specs.) 60 LF

4145 Install Drip edge, aluminum, .016" thick, 5" wide, white finish (See Tech Specs.) 60 LF

4146 Remove and Dispose Drip edge, galvanized, 5" wide, mill finish (See Tech Specs.) 60 LF

4147 Install Drip edge, galvanized, 5" wide, mill finish (See Tech Specs.) 60 LF

4148 Remove and Dispose Elbows, aluminum, 3" x 4", .025" thick, embossed (See Tech Specs.) 26 EA

4149 Install Elbows, aluminum, 3" x 4", .025" thick, embossed (See Tech Specs.) 26 EA

4150 Remove and Dispose Elbows, aluminum, 3" x 4", .025" thick, enameled (See Tech Specs.) 26 EA

4151 Install Elbows, aluminum, 3" x 4", .025" thick, enameled (See Tech Specs.) 26 EA

4152 Remove and Dispose Flashing, aluminum, mill finish, .032" thick (See Tech Specs.) 90 SF

4153 Install Flashing, aluminum, mill finish, .032" thick (See Tech Specs.) 90 SF

4154 Remove and Dispose Vent flashing, aluminum with lead ring, 2" pipe (See Tech Specs.) 9 EA

4155 Install Vent flashing, aluminum with lead ring, 2" pipe (See Tech Specs.) 9 EA

4156 Remove and Dispose Vent flashing, aluminum with lead ring, 3" pipe (See Tech Specs.) 9 EA

4157 Install Vent flashing, aluminum with lead ring, 3" pipe (See Tech Specs.) 9 EA

4158 Remove and Dispose Vent flashing, aluminum with lead ring, 4" pipe (See Tech Specs.) 9 EA

4159 Install Vent flashing, aluminum with lead ring, 4" pipe (See Tech Specs.) 9 EA

4160 Remove and Dispose Vent flashing, aluminum with lead ring, 1-1/2" pipe (See Tech Specs.) 9 EA

4161Install Vent flashing, aluminum with lead ring, 1-1/2" pipe (See Tech9EA
Specs.)

4162 Remove and Dispose Reglet, counter flashing for above, 12" wide, .032" aluminum (See Tech Specs.) 44 LF

4163Install Reglet, counter flashing for above, 12" wide, .032" aluminum44LF
(See Tech Specs.)
4164Remove and Dispose Roof vents, mushroom for built-up roofs, PVC, 6"16EA
high

4165 Install Roof vents, mushroom for built-up roofs, PVC, 6" high 16 EA

4166 Remove and Dispose Vents, one-way, aluminum (See Tech Specs.) 16 EA

4167 Install Vents, one-way, aluminum (See Tech Specs.) 16 EA

4168 Remove and Dispose Drains-scppr flr, oblique strn-CI, 6"x7" top, 2", 3"&4" pipe size (See Tech Specs.) 4 EA

4169Install Drains-scppr flr, oblique strn-CI, 6"x7" top, 2", 3"&4" pipe size4EA
(See Tech Specs.)
4170Remove and Dispose Drains, roof, flat metal deck, C.I. body, 12" C.I.4EA
dome, 3" pipe size (See Tech Specs.)
4171Install Drains, roof, flat metal deck, C.I. body, 12" C.I. dome,4EA
3" pipe size (See Tech Specs.)

4172 Remove and Dispose Drains, roof, flat mtl deck, galvanized body, 12"CI dome, 6" pipe (See Tech Specs.) 4 EA

4173Install Drains, roof, flat mtl deck, galvanized body, 12"CI dome, 6" pipe4EA
(See Tech Specs.)

4174 Remove and Dispose Drains, cornice, C.I., 45< or 90< outlet, 3" and 4" pipe size (See Tech Specs.) 4 EA

4175Install Drains, cornice, C.I., 45< or 90< outlet, 3" and 4" pipe size4EA
(See Tech Specs.)

4176 Remove and Dispose Drains, cornice, C.I., for galvanized body, 3" and 4" pipe size (See Tech Specs.) 4 EA

4177Install Drains, cornice, C.I., for galvanized body, 3" and 4" pipe size4EA
(See Tech Specs.)

4178 Remove and Dispose Elastomeric rfg,poly spray-on W/20mil silicone rbr ctg , 3"thk,r21,min (See Tech Specs.) 1,600 SF

4179Install Elastomeric rfg,poly spray-on W/20mil silicone rbr ctg ,1,600SF
3"thk,r21,min (See Tech Specs.)

4180 Remove and Dispose Built-up rfg,asph fl CT W/gvl,ctd gl base sht,3ply gl,nailable dk (See Tech Specs.) 5,200 SF

4181Install Built-up rfg,asph fl CT W/gvl,ctd gl base sht,3ply gl,nailable dk5,200SF
(See Tech Specs.)
4182Remove and Dispose Built-up rfg,asph fl CT W/gvl,ctd gl base sht,4ply gl5,200SF
fbr felt,mopped
4183Install Built-up rfg,asph fl CT W/gvl,ctd gl base sht,4ply gl5,200SF
fbr felt,mopped

4184 Remove and Dispose Cants, 4" x 4" treated timber, cut diagonally (See Tech Specs.) 90 LF

4185 Install Cants, 4" x 4" treated timber, cut diagonally (See Tech Specs.) 90 LF

4186Remove and Dispose B247Single-ply membrane, EPDM, 60 mil, 0.40 PS, fully5,200SF
adhered w/adhesive, w/4" seam tape (See Tech Specs.)
4187Install B247Single-ply membrane, EPDM, 60 mil, 0.40 PS, fully5,200SF
adhered w/adhesive, w/4" seam tape (See Tech Specs.)
4188Remove and Dispose Mod bit rfng, SBS mod, gran surf cap sheet, poly rein, mppd, 160 mils w/base sheet, #15 Glass Fiber Felt fully mopped to1,040SF
deck w/asphalt primer (See Tech Specs.)
4189Install Mod bit rfng, SBS mod, gran surf cap sheet, poly rein, mppd,1,040SF
160 mils w/base sheet, #15 Glass Fiber Felt fully mopped to
deck w/asphalt primer (See Tech Specs.)
4190Remove and Dispose Mod bit, SBS mod, smooth surf cap sheet, glass fiber rein, mppd, 160 mils w/base sheet, #15 Glass Fiber Felt fully mopped1,040SF
to deck w/asphalt primer (See Tech Specs.)
4191Install Mod bit, SBS mod, smooth surf cap sheet, glass fiber rein, mppd,1,040SF
160 mils w/base sheet, #15 Glass Fiber Felt fully mopped to
deck w/asphalt primer (See Tech Specs.)
4192Remove and Dispose Mod bit, APP mod, gran surface cap sheet, poly1,040SF
rein, torched, 180 mils w/base sheet, #15 Glass Fiber Felt fully mopped to
deck w/asphalt primer (See Tech Specs.)
4193Install Mod bit, APP mod, gran surface cap sheet, poly rein,1,040SF
torched, 180 mils w/base sheet, #15 Glass Fiber Felt fully mopped to
deck w/asphalt primer (See Tech Specs.)
4194Remove and Dispose Mod bit, APP mod, smooth surf cap sheet, poly rein, torched,1,040SF
160 mils w/base sheet, #15 Glass Fiber Felt fully mopped to
deck w/asphalt primer (See Tech Specs.)
4195Install Mod bit, APP mod, smooth surf cap sheet, poly rein, torched,1,040SF
160 mils w/base sheet, #15 Glass Fiber Felt fully mopped to
deck w/asphalt primer (See Tech Specs.)

4196 Remove and Dispose Roof coatings, asphalt primer, 5 gallon (See Tech Specs.) 20,000 SF

4197 Install Roof coatings, asphalt primer, 5 gallon (See Tech Specs.) 20,000 SF

4198 Remove and Dispose Bituminous asphalt coating, with fibers, troweled on, 1/2" thick (See Tech Specs.) 2,600 SF

4199Install Bituminous asphalt coating, with fibers, troweled on, 1/2" thick2,600SF
(See Tech Specs.)

4200 Remove and DisposeBuilt-up rfg,asph fl CT,ctd gl fbr base sht,3 plies,on nailable dks (See Tech Specs.) 2,000 SF

4201Install Built-up rfg,asph fl CT,ctd gl fbr base sht,3 plies,on nailable dks2,000SF
(See Tech Specs.)

4202 Remove and Dispose Built-up rfg,asph fl CT,ctd gl fbr base sht,4ply gl fbr felt,mopped (See Tech Specs.) 2,000 SF

4203Install Built-up rfg,asph fl CT,ctd gl fbr base sht,4ply gl fbr felt,mopped2,000SF
(See Tech Specs.)

4204 Remove and Dispose Rubber coating, silicone or stearate, sprayed on CMU, 2 coats (See Tech Specs.) 1,040 SF

4205Install Rubber coating, silicone or stearate, sprayed on CMU, 2 coats1,040SF
(See Tech Specs.)
4206Remove and Dispose Pitch Pockets, side extenders, 6" (See Tech18EA
Specs.)

4207 Install Pitch Pockets, side extenders, 6" (See Tech Specs.) 18 EA

4208 Remove and Dispose Pitch Pockets, adjustable, 4" to 7", welded corners, 4" deep (See Tech Specs.) 18 EA

4209Install Pitch Pockets, adjustable, 4" to 7", welded corners, 4" deep18EA
(See Tech Specs.)

4210 Remove and Dispose Walkway for BUR, asph impregnated, 3' x 3' x 3/4" thk (See Tech Specs.) 700 SF

4211 Install Walkway for BUR, asph impregnated, 3' x 3' x 3/4" thk (See Tech Specs.) 700 SF

4212 Remove and Dispose Caulking & sealants, polyurethane, 1 or 2 component, bulk (See Tech Specs.) 90 LF

4213Install Caulking & sealants, polyurethane, 1 or 2 component, bulk90LF
(See Tech Specs.)

4214 Remove and Dispose Caulking and sealants, silicone rubber, cartridges (See Tech Specs.) 90 LF

4215Install Caulking and sealants, silicone rubber, cartridges (See Tech90LF
Specs.)

4216 Remove and Dispose Caulking and sealants, resin epoxy coating, 2 component, heavy duty (See Tech Specs.) 90 LF

4217Install Caulking and sealants, resin epoxy coating, 2 component, heavy90LF
duty (See Tech Specs.)

4218 Remove and Dispose Caulking and sealants, neoprene gaskets, closed cell, 1/4" x 3/4" (See Tech Specs.) 90 LF

4219Install Caulking and sealants, neoprene gaskets, closed cell, 1/4" x 3/4"90LF
(See Tech Specs.)

4220 Remove and Dispose Framing, miscellaneous, nailers, treated, wood construction, 2" x 6" (See Tech Specs.) 90 LF

4221Install Framing, miscellaneous, nailers, treated, wood construction, 2" x 6"90LF
(See Tech Specs.)

4222 Remove and Dispose Framing, miscellaneous, nailers, treated, wood construction, 2" x 4" (See Tech Specs.) 90 LF

4223Install Framing, miscellaneous, nailers, treated, wood construction, 2" x 4"90LF
(See Tech Specs.)

4224 Remove and Dispose Framing, miscellaneous, nailers, treated, wood construction, 2" x 8" (See Tech Specs.) 90 LF

4225Install Framing, miscellaneous, nailers, treated, wood construction, 2" x 8"90LF
(See Tech Specs.)

4226 Remove and Dispose Roof deck insul, polyisocyanurate, 2#/CF density, 2" thk R14.29 (See Tech Specs.) 5,000 SF

4227Install Roof deck insul, polyisocyanurate, 2#/CF density, 2" thk R14.295,000SF
(See Tech Specs.)
4228Remove and Dispose Roof deck insulation, polyisocyanurate 2#/CF5,000SF
density, tapered for drainage (See Tech Specs.)
4229Install Roof deck insulation, polyisocyanurate 2#/CF density,5,000SF
tapered for drainage (See Tech Specs.)

4230 Remove and Dispose Roof deck insulation, expanded polystyrene, 2" thick R7.69 (See Tech Specs.) 5,000 SF

4231Install Roof deck insulation, expanded polystyrene, 2" thick R7.695,000SF
(See Tech Specs.)

4232 Remove and Dispose Roof deck insulation, expanded polystyrene, tapered for drainage (See Tech Specs.) 880 SF

4233Install Roof deck insulation, expanded polystyrene, tapered for drainage880SF
(See Tech Specs.)
4234Remove and Dispose Roof deck insul., extruded polystyrene, 60 PSI4,000SF
comp. strength, 2" thick R10 (See Tech Specs.)
4235Install Roof deck insul., extruded polystyrene, 60 PSI comp.4,000SF
strength, 2" thick R10 (See Tech Specs.)

4236 Remove and Dispose Roof deck insul., extruded polystyrene, 60 PSI comp. strgth., tapered (See Tech Specs.) 1,040 SF

4237Install Roof deck insul., extruded polystyrene, 60 PSI comp. strgth., tapered1,040SF
(See Tech Specs.)

4238 Remove and Dispose Roof hatch, 2'-6" x 3', w/curb, 1" fbgls insul, galv stl curb/cover (See Tech Specs.) 1 EA

4239Install Roof hatch, 2'-6" x 3', w/curb, 1" fbgls insul, galv stl curb/cover1EA
(See Tech Specs.)

4240 Remove and Dispose Skylight, insulated safety glass with aluminum frame (See Tech Specs.) 260 SF

4241 Install Skylight, insulated safety glass with aluminum frame (See Tech Specs.) 160 SF

4242 Remove and Dispose Ladder, steel, 20" wide, bolted to concrete, with cage (See Tech Specs.) 70 VLF

4243 Install Ladder, steel, 20" wide, bolted to concrete, with cage (See Tech Specs.) 70 VLF

4244 Remove and DisposeLadder, steel, 20" wide, bolted to concrete, w/o cage (See Tech Specs.) 70 VLF

4245 Install Ladder, steel, 20" wide, bolted to concrete, w/o cage (See Tech Specs.) 70 VLF

4246 Replace Insulation/finish syst, field applied, 1 inch (See Tech Specs.) 520 SF

4247 Replace Insulation/finish syst, field applied, 2 inch (See Tech Specs.) 260 SF

4248 Replace Insulation/finish syst, field applied, 3 inch (See Tech Specs.) 260 SF

4249 Replace Ductwork, galv steel, 500-1000 lb, 12"-14"h, 18"w (See Tech Specs.) 90 LB

4250 Replace Ductwork, galv steel, 500-1000 lb, 12"-14"h, 24"w (See Tech Specs.) 90 LB

4251 Replace Ductwork, galv steel, 500-1000 lb, 12"-14"h, 48"w (See Tech Specs.) 90 LB

4252 Pipe, copper, 3/8" dia., type K (See Tech Specs.) 160 LF

4253 Pipe insulation, 3/8" copper pipe, rubber tubing (See Tech Specs.) 160 LF

4254 Vent and Pipe Replacement, PVC schedule 40, 2" dia. (See Tech Specs.) 18 LF

4255 Vent and Pipe Replacement, PVC schedule 40, 3" dia. (See Tech Specs.) 18 LF

4256 Vent and Pipe Replacement, PVC schedule 40, 4" dia. (See Tech Specs.) 18 LF

4257 HVAC demo, Mech equipment (See Tech Specs.) 2,000 LBS

4258 Air cooled condenser, 2 tons, reinstallation (See Tech Specs.) 6 EA

4259 Air cooled condenser, 16 tons,reinstallation (See Tech Specs.) 6 EA

4260 Roof top unit, 7.5 tons, single zone, reinstallation (See Tech Specs.) 6 EA

4261 Replace Wire, 600 volt, type THW, copper, stranded, #12 (See Tech Specs.) 200 LF

4262 Replace Wire, 600 volt, type THW, copper, solid, #12 (See Tech Specs.) 200 LF

4263 Replace Wire, 600 volt, type THW, copper, stranded, #10 (See Tech Specs.) 200 LF

4264 Replace Wire, 600 volt, type THW, copper, solid, #10 (See Tech Specs.) 200 LF

4265Replace Wire, 600 volt, type THW, copper, stranded, #8 (See Tech200LF
Specs.)
4266Replace Wire, 600 volt, type THW, copper, stranded, #6 (See Tech200LF
Specs.)
4267ReplaceWire, 600 volt, type THW, copper, stranded, #4 (See Tech200LF
Specs.)
4268Replace Wire, 600 volt, type THW, copper, stranded, #3 (See Tech200LF
Specs.)
4269Replace Wire, 600 volt, type THW, copper, stranded, #2 (See Tech200LF
Specs.)
4270Replace Wire, 600 volt, type THW, copper, stranded, #1 (See Tech200LF
Specs.)

4271 Replace Wire, 600 volt, type THWN-THHN, copper, stranded, #12 (See Tech Specs.) 200 LF

4272 Replace Wire, 600 volt, type THWN-THHN, copper, solid, #12 (See Tech Specs.) 200 LF

4273 Replace Wire, 600 volt, type THWN-THHN, copper, stranded, #10 (See Tech Specs.) 200 LF

4274 Replace Wire, 600 volt, type THWN-THHN, copper, solid, #10 (See Tech Specs.) 200 LF

4275 Replace Wire, 600 volt, type THWN-THHN, copper, stranded, #8 (See Tech Specs.) 200 LF

4276 Replace Wire, 600 volt, type THWN-THHN, copper, stranded, #6 (See Tech Specs.) 200 LF

4277 Replace Wire, 600 volt, type THWN-THHN, copper, stranded, #4 (See Tech Specs.) 200 LF

4278Replace Cond to 15' H,incl 2 termn,2 elb&11 bm CLP per 100',galv stl,1/2" dia100LF
(See Tech Specs.)
4279Replace Cond to 15' H,incl 2 termn,2 elb&11 bm CLP per 100',galv stl,3/4" dia100LF
(See Tech Specs.)
4280Replace Cond to 15' H,incl 2 termn,2 elb&11 bm CLP per 100',galv stl,1"100LF
dia (See Tech Specs.)

4281 Replace Cond to 15' H,incl 2 termn,2 elb&11 bm CLP per 100',galv stl,1-1/4"dia (See Tech Specs.) 100 LF

4282 Replace Cond to 15' H,incl 2 termn,2 elb&11 bm CLP per 100',galv stl,1-1/2"dia (See Tech Specs.) 100 LF

4283Replace Cond to 15' H,incl 2 termn,2 elb&11 bm CLP per 100',galv stl,2"100LF
dia (See Tech Specs.)

4284 Replace Cond to 15' H,incl 2 termn,2 elb&11 bm CLP per 100',galv stl,2-1/2"dia (See Tech Specs.) 100 LF

4285Replace Cond to 15' H,incl 2 termn,2 elb&11 bm CLP per 100',galv stl,3"100LF
dia (See Tech Specs.)

4286 Replace Cond to 15' H,incl 2 termn,2 elb&11 bm CLP per 100',galv stl,3-1/2"dia (See Tech Specs.) 100 LF

4287Relace Cond to 15' H,incl 2 termn,2 elb&11 bm CLP per 100',galv stl,4"100LF
dia (See Tech Specs.)

4288 Replace Safety switches, heavy duty, 240 volt, 3 pole NEMA 1 fusible, 30 amp (See Tech Specs.) 8 EA

4289 Replace Safety switches, heavy duty, 240 volt, 3 pole NEMA 1 fusible, 60 amp (See Tech Specs.) 8 EA

4290 Replace Safety switches, heavy duty, 240 volt, 3 pole NEMA 1 fusible, 100 amp (See Tech Specs.) 8 EA

4291 Replace Wire, 600 volt, type THW, copper, stranded, 1/0 (See Tech Specs.) 100 LF

4292 Replace Wire, 600 volt, type THW, copper, stranded, 2/0 (See Tech Specs.) 100 LF

4293 Replace Wire, 600 volt, type THW, copper, stranded, 3/0 (See Tech Specs.) 100 LF

4294 Replace Wire, 600 volt, type THW, copper, stranded, 4/0 (See Tech Specs.) 100 LF

4295 Remove & dispose PUF or Built-up Roofing w/Asbestos Mastic (ACM) 100 SF

4001 Grand Total