SECOND-SchedulePrices_W912C320B0001_RoofRepairs_20200306.xlsx
XLSX spreadsheet 40 KB Posted
- Solicitation number
- W912C320B0001
View the file
Other files
Show all 27
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SECOND OPTION
| SCHEDULE OF PRICES | |||||
| SECOND OPTION PERIOD: IFB W912C320B0001, ROOF REPAIR INSPECTION & MAINTENANCE | |||||
| Item | Item Description | Estimated | Unit | Unit Cost | Total Cost |
| Quantity | |||||
| 2001 | Roof Inspection Survey and Written Report with As-Built Roof Plan | 125,000 | SF | ||
| (Section 01 11 00, Para 1.2, 1.2.1, 1.2.2.a through h) |
2002 Provide As-Built Roof Plans (Section 01 11 00, Para 1.2.2) 125,000 SF
| 2003 | Sampling & Laboratory Testing and Test Report for Asbestos Materials | 15 | EA |
| (Section 01 11 00, Para 1.2.2.e and Para 1.4.6) |
| 2004 | Repair Concrete Roof (Plain Concrete) | 1,500 | SF |
| (Section 01 11 00, Para 1.4.1.a, b, c, d, e) (See Tech Specs.) |
| 2005 | Repair Corrugated Metal Roof | 5,000 | SF |
| (Section 01 11 00, Para 1.4.2.a, b, c) (See Tech Specs.) |
| 2006 | Remove and Dispose Corrugated Metal Roof Panels, GA 24 | 520 | SF |
| (Section 01 11 00, Para 1.4.2.e) (See Tech Specs.) |
| 2007 | Install Corrugated Metal Roof Panels, GA 24 | 520 | SF |
| (Section 01 11 00, Para 1.4.2.e) (See Tech Specs.) |
| 2008 | Remove and Dispose Corrugated Metal Roof Panels, GA 26 | 520 | SF |
| (Section 01 11 00, Para 1.4.2.e) (See Tech Specs.) |
| 2009 | Install Corrugated Metal Roof Panels, GA 26 | 520 | SF |
| (Section 01 11 00, Para 1.4.2.e) (See Tech Specs.) |
| 2010 | Repair Corrugated Metal Roof: Painting | 5,000 | SF |
| (Section 01 11 00, Para 1.4.2. d, f, and g) |
| 2011 | Repair Modified Bitumen (Insulation, and 3-ply w/cold adhesvie) | 200 | SF |
| (See Tech Specs.) |
| 2012 | Repair Modified Bitumen (Insulation, and 3-ply w/torched seams) | 200 | SF |
| (See Tech Specs.) |
| 2013 | Repair Modified Bitumen (Insulation, and 2-ply w/cold | 200 | SF |
| adhesive or torched seams) (See Tech Specs.) |
| 2014 | Repair Light weight Concrete insulation, Lt weight | 880 | SF |
| cellular roof fill, Port & Cem. 2 inch thick average and foaming agent | |||
| (See Tech Specs.) |
| 2015 | Remove and Dispose Light weight Concrete insulation, Lt weight | 880 | SF |
| cellular roof fill, Port & Cem. 2 inch thick average and foaming agent | |||
| (See Tech Specs.) |
| 2016 | Install Light weight Concrete insulation, Lt weight | 880 | SF |
| cellular roof fill, Port & Cem. 2 inch thick average and foaming agent | |||
| (See Tech Specs.) |
| 2017 | Repair Light weight Concrete insulation, Lt weight | 880 | SF |
| cellular roof fill, Port & Cem. 4 inch thick average and foaming agent | |||
| (See Tech Specs.) |
| 2018 | Remove and Dispose Light weight Concrete insulation, Lt weight | 880 | SF |
| cellular roof fill, Port & Cem. 4 inch thick average and foaming agent | |||
| (See Tech Specs.) |
| 2019 | Install Light weight Concrete insulation, Lt weight | 880 | SF |
| cellular roof fill, Port & Cem. 4 inch thick average and foaming agent | |||
| (See Tech Specs.) |
| 2020 | Remove and Dispose Insulation 2-inch Average Thick | 1,500 | SF |
| (See Tech Specs.) |
2021 Install Insulation 2-inch Average Thick (See Tech Specs.) 1,500 SF
2022 Remove and Dispose E.P.D.M with Insulation (See Tech Specs.) 2,000 SF
2023 Install E.P.D.M with Insulation (See Tech Specs.) 2,000 SF
2024 Remove and Dispose Built-up Roofing (Insulation 3-ply, Hot Adhesive and Gravel) (See Tech Specs.) 5,000 SF
| 2025 | Install Built-up Roofing (Insulation 3-ply, Hot Adhesive and Gravel) | 5,000 | SF |
| (See Tech Specs.) |
| 2026 | Repair Single Ply with adhesive or Asphalt Moppping | 1,040 | SF |
| (See Tech Specs.) |
2027 Repair Insulation and Hot Asphalt Plies 520 SF
| 2028 | Remove and Dispose Standing Seam Metal Over Insulation | 260 | SF |
| (Section 07 61 13) |
| 2029 | Install Standing Seam Metal Over Insulation | 260 | SF |
| (Section 07 61 13) |
| 2030 | Remove and Dispose Asphalt Shingles over Insulation and over | 100 | SF |
| standing Seam Metal Roof (See Tech Specs.) |
| 2031 | Install Asphalt Shingles over Insulation and over | 100 | SF |
| standing Seam Metal Roof (See Tech Specs.) |
2032 Repair Water Proof Asphalt Coating (See Tech Specs.) 200 SF
| 2033 | Repair Sprayed Polyurethane with top Silicone Coating (PUF) | 7,800 | SF |
| (See Tech Specs.) |
| 2034 | Remove and Dispose Primer and Elastomeric Coating | 7,800 | SF |
| (See Tech Specs.) |
2035 Install Primer and Elastomeric Coating (See Tech Specs.) 7,800 SF
| 2036 | Blisters Repairs for Modified Bitumen | 260 | SF |
| (Section 01 11 00, Para 1.4.3) (See Tech Specs.) |
| 2037 | Blister Repairs for E.P.D.M. | 520 | SF |
| (Section 01 11 00, Para 1.4.3) (See Tech Specs.) |
| 2038 | Blister Repairs for Built-up Roofing | 1,040 | SF |
| (Section 01 11 00, Para 1.4.3) (See Tech Specs.) |
| 2039 | Blister Repairs for PUF | 520 | SF |
| (Section 01 11 00, Para 1.4.5.d and e.(1) through (8) (See Tech Specs.) |
| 2040 | PUF Minor Repairs | 260 | SF |
| (Section 01 11 00 , Para 1.4.5.C.(1) through (5) (See Tech Specs.) |
| 2041 | PUF or Built-up Roofing Repairs w/Asbestos Mastic (ACM) | 260 | SF |
| (Section 01 11 00, Para 1.4.6) (See Tech Specs.) |
| 2042 | PUF or Built-up Roofing Replacement w/Asbestos Mastic (ACM) | 5,200 | SF |
| (Section 01 11 00, Para 1.4.6) (See Tech Specs.) |
| 2043 | Remove and Dispose Radiant Barrier Blanket | 130,000 | SF |
| Section 01 11 00, Para 1.5, 1.5.1 and 1.5.2) (See Tech Specs.) |
| 2044 | Install Radiant Barrier Blanket | 130,000 | SF |
| Section 01 11 00, Para 1.5, 1.5.1 and 1.5.2) (See Tech Specs.) |
| 2045 | Repair Cracks at Roofing Systems | 1,040 | LF |
| (Section 01 11 00, Para 1.4.3.e) (See Tech Specs.) |
| 2046 | Correct Water Ponding Areas at Roofing Systems | 1,040 | SF |
| (Section 01 11 00, Para 1.4.3.d) (See Tech Specs.) |
| 2047 | Maintenance for Roofing Systems | 130,000 | SF |
| (Section 01 11 00, Par1.9.a through c) (See Tech Specs.) |
| 2048 | Cement parging, 2 coats, waterproofed Portland cement (See Tech | 1,040 | SF |
| Specs.) |
| 2049 | Structural steel projects, steel surface treatments, wire brush, hand | 520 | SF |
| sanding (See Tech Specs.) |
| 2050 | Struct. steel projects,sprayed painting,univ primer plus1 paint coat, | 520 | SF |
| phenolic, modified alkyd (See Tech Specs.) |
| 2051 | Near white blast, (SSPC-10), exist coat blistered/pitted, | 520 | SF |
| 9.0 #/SF (See Tech Specs.) |
| 2052 | Structural steel project,pnts&prot ctg,sprayed,zinc rich primer,epoxy, | 520 | SF |
| spray,organic (See Tech Specs.) |
2053 Strl st projs, pnts & prot ctg, sprayed, epoxy, intmd or topcoat (See Tech Specs.) 520 SF
| 2054 | Epoxy dk ctg, bitumen modified polyurethane, fld applied, | 520 | SF |
| 55 mils thk (See Tech Specs.) |
2055 Remove and Dispose Open web joist girders, average (See Tech Specs.) 1 TON
2056 Install Open web joist girders, average (See Tech Specs.) 1 TON
2057 Remove and Dispose Lightweight framing, angle, field fab, 3" x 3" x 3/8" (See Tech Specs.) 45 LF
| 2058 | Install Lightweight framing, angle, field fab, 3" x 3" x 3/8" (See Tech | 45 | LF |
| Specs.) |
2059 Remove and Dispose Framing, joists, 2" x 12" (See Tech Specs.) 55 LF
2060 Install Framing, joists, 2" x 12" (See Tech Specs.) 55 LF
2061 Remove and Dispose Framing, joists, 2" x 4" (See Tech Specs.) 55 LF
2062 Install Framing, joists, 2" x 4" (See Tech Specs.) 55 LF
2063 Remove and Dispose Framing, joists, 2" x 6" (See Tech Specs.) 55 LF
2064 Install Framing, joists, 2" x 6" (See Tech Specs.) 55 LF
2065 Remove and Dispose Framing, joists, 2" x 8" (See Tech Specs.) 55 LF
2066 Install Framing, joists, 2" x 8" (See Tech Specs.) 55 LF
2067 Remove and Dispose Framing, joists, 2" x 10" (See Tech Specs.) 55 LF
2068 Install Framing, joists, 2" x 10" (See Tech Specs.) 55 LF
2069 Remove and Dispose Framing, roofs, fascia boards, 2" x 8" (See Tech Specs.) 55 LF
2070 Install Framing, roofs, fascia boards, 2" x 8" (See Tech Specs.) 55 LF
2071 Remove and Dispose Framing, roofs, rafters, to 4 in 12 pitch, 2" x 8" (See Tech Specs.) 55 LF
2072 Install Framing, roofs, rafters, to 4 in 12 pitch, 2" x 8" (See Tech Specs.) 55 LF
2073 Remove and Dispose Framing, roofs, rafters, to 4 in 12 pitch, 2" x 6" (See Tech Specs.) 55 LF
2074 Install Framing, roofs, rafters, to 4 in 12 pitch, 2" x 6" (See Tech Specs.) 55 LF
2075 Remove and Dispose Framing, roofs, ridge board, #2 or better, 1" x 8" (See Tech Specs.) 55 LF
2076 Install Framing, roofs, ridge board, #2 or better, 1" x 8" (See Tech Specs.) 55 LF
2077 Remove and Dispose Framing, roofs, roof cants, split, 4" x 4" (See Tech Specs.) 55 LF
2078 Install Framing, roofs, roof cants, split, 4" x 4" (See Tech Specs.) 55 LF
2079 Remove and Dispose Framing, miscellaneous, nailers, treated, wood construction, 2" x 6" (See Tech Specs.) 55 LF
| 2080 | Install Framing, miscellaneous, nailers, treated, wood construction, | 55 | LF |
| 2" x 6" (See Tech Specs.) |
2081 Remove and Dispose Exp jt,butyl or nprn ctr W/foam insul,alum,.032"thk for opng to 2-1/2" (See Tech Specs.) 104 LF
| 2082 | Install Exp jt,butyl or nprn ctr W/foam insul,alum,.032"thk for opng to | 104 | LF |
| 2-1/2" (See Tech Specs.) |
2083 Remove and Dispose Exp jt, butyl or nprn ctr W/foam insul, alum, for jt opngs to 3-1/2" (See Tech Specs.) 104 LF
| 2084 | Install Exp jt, butyl or nprn ctr W/foam insul, alum, for jt opngs to | 104 | LF |
| 3-1/2" (See Tech Specs.) |
2085 Remove and Dispose Expansion joint, roof joint with extruded aluminum cover, 2" (See Tech Specs.) 55 LF
2086 Install Expansion joint, roof joint with extruded aluminum cover, 2" (See Tech Specs.) 55 LF
2087 Remove and Dispose Expansion joint, roof to wall joint with extruded aluminum cover (See Tech Specs.) 55 LF
| 2088 | Install Expansion joint, roof to wall joint with extruded aluminum cover | 55 | LF |
| (See Tech Specs.) |
| 2089 | Remove and Dispose Expansion joint, wall joint, closed cell foam on PVC | 55 | LF |
| cover, 9" wide (See Tech Specs.) |
| 2090 | Remove and Dispose Expansion joint, wall joint, closed cell foam on PVC | 55 | LF |
| cover, 9" wide (See Tech Specs.) |
2091 Remove and Dispose Expansion jt, neoprene, dbl-seal type with thick center, 4-1/2" wide (See Tech Specs.) 55 LF
| 2092 | Install Expansion jt, neoprene, dbl-seal type with thick center, | 55 | LF |
| 4-1/2" wide (See Tech Specs.) |
2093 Cleaning high pressure water only, minimum (See Tech Specs.) 130,000 SF
2094 Remove and Dispose Sheathing, with boards, 1" x 12" boards, laid diagonal (See Tech Specs.) 55 SF
2095 Install Sheathing, with boards, 1" x 12" boards, laid diagonal (See Tech Specs.) 55 SF
2096 Remove and Dispose Sheathing, plywood on roof, CDX, 5/8" thick (See Tech Specs.) 55 SF
2097 Install Sheathing, plywood on roof, CDX, 5/8" thick (See Tech Specs.) 55 SF
2098 Remove and Dispose Steel roofing, on steel frame, corrugated or ribbed, galv, 24 ga (See Tech Specs.) 55 SF
| 2099 | Install Steel roofing, on steel frame, corrugated or ribbed, galv, 24 ga | 55 | SF |
| (See Tech Specs.) |
2100 Remove and Dispose Steel roofing, on steel frame, corrugated or ribbed, galv, 26 ga (See Tech Specs.) 55 SF
| 2101 | Install Steel roofing, on steel frame, corrugated or ribbed, galv, 26 ga | 55 | SF |
| (See Tech Specs.) |
2102 Remove and Dispose roof flat profile, 1-3/4" stand. seams, 12" w, stand. fin. 24 ga. (See Tech Specs.) 55 SF
| 2103 | Install Steel roof flat profile, 1-3/4" stand. seams, 12" w, stand. fin. 24 ga. | 55 | SF |
| (See Tech Specs.) |
2104 Remove and Dispose Aluminum roofing, corrugated, painted, .032" thick (See Tech Specs.) 55 SF
| 2105 | Install Aluminum roofing, corrugated, painted, .032" thick (See Tech | 55 | SF |
| Specs.) |
2106 Remove and Dispose Asphalt shingles, #15 felt underlayment (See Tech Specs.) 55 SF
2107 Install Asphalt shingles, #15 felt underlayment (See Tech Specs.) 55 SF
2108 Remove and Dispose Asphalt shingles, std strip shingles, inorganic, class A, 210-235 lb/sq (See Tech Specs.) 55 SF
| 2109 | Install Asphalt shingles, std strip shingles, inorganic, class A, | 55 | SF |
| 210-235 lb/sq (See Tech Specs.) |
2110 Remove and Dispose Steel roofing, ridge, galvanized, 20" wide (See Tech Specs.) 55 LF
2111 Install Steel roofing, ridge, galvanized, 20" wide (See Tech Specs.) 55 LF
2112 Remove and Dispose Fascia, aluminum, .032" thick, colored, NO furring included (See Tech Specs.) 55 SF
| 2113 | Install Fascia, aluminum, .032" thick, colored, NO furring included | 55 | SF |
| (See Tech Specs.) |
| 2114 | Remove and Dispose Fascia, steel, galv and enameled, stock, NO furring, | 55 | SF |
| long panels (See Tech Specs.) |
| 2115 | Install Fascia, steel, galv and enameled, stock, NO furring, | 55 | SF |
| long panels (See Tech Specs.) |
2116 Remove and Dispose Gutters, aluminum, 5" box type, enameled (See Tech Specs.) 160 LF
2117 Install Gutters, aluminum, 5" box type, enameled (See Tech Specs.) 160 LF
2118 Remove and Dispose Gutters, alum, 5" x 6" comb fascia & gutter, .032" thick, enameled (See Tech Specs.) 160 LF
| 2119 | Install Gutters, alum, 5" x 6" comb fascia & gutter, .032" thick, | 160 | LF |
| enameled (See Tech Specs.) |
| 2120 | Remove and Dispose Gutters, steel, galv, half round or box, 28 ga, 5" | 104 | LF |
| wide, enameled (See Tech Specs.) |
| 2121 | Install Gutters, steel, galv, half round or box, 28 ga, 5" wide, | 104 | LF |
| enameled (See Tech Specs.) |
2122 Remove and Dispose Gravel stop, galv steel, 6" face height (See Tech Specs.) 104 LF
2123 Install Gravel stop, galv steel, 6" face height (See Tech Specs.) 104 LF
2124 Remove and Dispose Gravel stop, aluminum, .050" thick, 6" height, painted (See Tech Specs.) 104 LF
2125 Install Gravel stop, aluminum, .050" thick, 6" height, painted (See Tech Specs.) 104 LF
2126 Remove and Dispose Gravel Gravel stop, aluminum, .050" thick, 8" height, painted (See Tech Specs.) 104 LF
2127 Install Gravel stop, aluminum, .050" thick, 8" height, painted (See Tech Specs.) 104 LF
2128 Remove and Dispose Gravel Gravel Gutters, aluminum, 5" box type, .032" thick, plain (See Tech Specs.) 160 LF
| 2129 | Install Gutters, aluminum, 5" box type, .032" thick, plain (See Tech | 160 | LF |
| Specs.) |
2130 Remove and Dispose Gutters, steel, galv, half round or box, 28 ga, 5" wide, plain (See Tech Specs.) 160 LF
2131 Install Gutters, steel, galv, half round or box, 28 ga, 5" wide, plain (See Tech Specs.) 160 LF
2132 Remove and Dispose Gravel stop, aluminum, .050" thick, 6" height, duranodic finish (See Tech Specs.) 104 LF
| 2133 | Install Gravel stop, aluminum, .050" thick, 6" height, duranodic finish | 104 | LF |
| (See Tech Specs.) |
2134 Remove and Dispose Gravel stop, aluminum, .050" thick, 8" height, duranodic finish (See Tech Specs.) 104 LF
| 2135 | Install Gravel stop, aluminum, .050" thick, 8" height, duranodic finish | 104 | LF |
| (See Tech Specs.) |
2136 Remove and Dispose Downspouts, aluminum 3" x 4", .024" thick, enameled (See Tech Specs.) 60 LF
2137 Install Downspouts, aluminum 3" x 4", .024" thick, enameled (See Tech Specs.) 60 LF
| 2138 | Remove and Dispose Downspouts, steel, rectangular, plain, 28 ga, galvanized, | 60 | LF |
| 3" x 4" (See Tech Specs.) |
| 2139 | Install Downspouts, steel, rectangular, plain, 28 ga, galvanized, | 60 | LF |
| 3" x 4" (See Tech Specs.) |
2140 Remove and Dispose Downspouts, steel, rect, epoxy painted, 24 ga, corrugated, 3" x 4" (See Tech Specs.) 60 LF
| 2141 | Install Downspouts, steel, rect, epoxy painted, 24 ga, corrugated, | 60 | LF |
| 3" x 4" (See Tech Specs.) |
2142 Remove and Dispose Drip edge, aluminum, .016" thick, 5" wide, mill finish (See Tech Specs.) 60 LF
2143 Install Drip edge, aluminum, .016" thick, 5" wide, mill finish (See Tech Specs.) 60 LF
2144 Remove and Dispose and Dispose Drip edge, aluminum, .016" thick, 5" wide, white finish (See Tech Specs.) 60 LF
2145 Install Drip edge, aluminum, .016" thick, 5" wide, white finish (See Tech Specs.) 60 LF
2146 Remove and Dispose Drip edge, galvanized, 5" wide, mill finish (See Tech Specs.) 60 LF
2147 Install Drip edge, galvanized, 5" wide, mill finish (See Tech Specs.) 60 LF
2148 Remove and Dispose Elbows, aluminum, 3" x 4", .025" thick, embossed (See Tech Specs.) 26 EA
| 2149 | Install Elbows, aluminum, 3" x 4", .025" thick, embossed (See Tech | 26 | EA |
| Specs.) |
2150 Remove and Dispose Elbows, aluminum, 3" x 4", .025" thick, enameled (See Tech Specs.) 26 EA
| 2151 | Install Elbows, aluminum, 3" x 4", .025" thick, enameled (See Tech | 26 | EA |
| Specs.) |
2152 Remove and Dispose Flashing, aluminum, mill finish, .032" thick (See Tech Specs.) 90 SF
2153 Install Flashing, aluminum, mill finish, .032" thick (See Tech Specs.) 90 SF
2154 Remove and Dispose Vent flashing, aluminum with lead ring, 2" pipe (See Tech Specs.) 9 EA
2155 Install Vent flashing, aluminum with lead ring, 2" pipe (See Tech Specs.) 9 EA
2156 Remove and Dispose Vent flashing, aluminum with lead ring, 3" pipe (See Tech Specs.) 9 EA
2157 Install Vent flashing, aluminum with lead ring, 3" pipe (See Tech Specs.) 9 EA
2158 Remove and Dispose Vent flashing, aluminum with lead ring, 4" pipe (See Tech Specs.) 9 EA
2159 Install Vent flashing, aluminum with lead ring, 4" pipe (See Tech Specs.) 9 EA
2160 Remove and Dispose Vent flashing, aluminum with lead ring, 1-1/2" pipe (See Tech Specs.) 9 EA
| 2161 | Install Vent flashing, aluminum with lead ring, 1-1/2" pipe (See Tech | 9 | EA |
| Specs.) |
2162 Remove and Dispose Reglet, counter flashing for above, 12" wide, .032" aluminum (See Tech Specs.) 44 LF
| 2163 | Install Reglet, counter flashing for above, 12" wide, .032" aluminum | 44 | LF |
| (See Tech Specs.) |
| 2164 | Remove and Dispose Roof vents, mushroom for built-up roofs, PVC, 6" | 16 | EA |
| high |
2165 Install Roof vents, mushroom for built-up roofs, PVC, 6" high 16 EA
2166 Remove and Dispose Vents, one-way, aluminum (See Tech Specs.) 16 EA
2167 Install Vents, one-way, aluminum (See Tech Specs.) 16 EA
2168 Remove and Dispose Drains-scppr flr, oblique strn-CI, 6"x7" top, 2", 3"&4" pipe size (See Tech Specs.) 4 EA
| 2169 | Install Drains-scppr flr, oblique strn-CI, 6"x7" top, 2", 3"&4" pipe size | 4 | EA |
| (See Tech Specs.) |
| 2170 | Remove and Dispose Drains, roof, flat metal deck, C.I. body, 12" C.I. | 4 | EA |
| dome, 3" pipe size (See Tech Specs.) |
| 2171 | Install Drains, roof, flat metal deck, C.I. body, 12" C.I. dome, | 4 | EA |
| 3" pipe size (See Tech Specs.) |
2172 Remove and Dispose Drains, roof, flat mtl deck, galvanized body, 12"CI dome, 6" pipe (See Tech Specs.) 4 EA
| 2173 | Install Drains, roof, flat mtl deck, galvanized body, 12"CI dome, 6" pipe | 4 | EA |
| (See Tech Specs.) |
2174 Remove and Dispose Drains, cornice, C.I., 45< or 90< outlet, 3" and 4" pipe size (See Tech Specs.) 4 EA
| 2175 | Install Drains, cornice, C.I., 45< or 90< outlet, 3" and 4" pipe size | 4 | EA |
| (See Tech Specs.) |
2176 Remove and Dispose Drains, cornice, C.I., for galvanized body, 3" and 4" pipe size (See Tech Specs.) 4 EA
| 2177 | Install Drains, cornice, C.I., for galvanized body, 3" and 4" pipe size | 4 | EA |
| (See Tech Specs.) |
2178 Remove and Dispose Elastomeric rfg,poly spray-on W/20mil silicone rbr ctg , 3"thk,r21,min (See Tech Specs.) 1,600 SF
| 2179 | Install Elastomeric rfg,poly spray-on W/20mil silicone rbr ctg , | 1,600 | SF |
| 3"thk,r21,min (See Tech Specs.) |
2180 Remove and Dispose Built-up rfg,asph fl CT W/gvl,ctd gl base sht,3ply gl,nailable dk (See Tech Specs.) 5,200 SF
| 2181 | Install Built-up rfg,asph fl CT W/gvl,ctd gl base sht,3ply gl,nailable dk | 5,200 | SF |
| (See Tech Specs.) |
| 2182 | Remove and Dispose Built-up rfg,asph fl CT W/gvl,ctd gl base sht,4ply gl | 5,200 | SF |
| fbr felt,mopped |
| 2183 | Install Built-up rfg,asph fl CT W/gvl,ctd gl base sht,4ply gl | 5,200 | SF |
| fbr felt,mopped |
2184 Remove and Dispose Cants, 4" x 4" treated timber, cut diagonally (See Tech Specs.) 90 LF
2185 Install Cants, 4" x 4" treated timber, cut diagonally (See Tech Specs.) 90 LF
| 2186 | Remove and Dispose B247Single-ply membrane, EPDM, 60 mil, 0.40 PS, fully | 5,200 | SF |
| adhered w/adhesive, w/4" seam tape (See Tech Specs.) |
| 2187 | Install B247Single-ply membrane, EPDM, 60 mil, 0.40 PS, fully | 5,200 | SF |
| adhered w/adhesive, w/4" seam tape (See Tech Specs.) |
| 2188 | Remove and Dispose Mod bit rfng, SBS mod, gran surf cap sheet, poly rein, mppd, | 1,040 | SF |
| 160 mils w/base sheet, #15 Glass Fiber Felt fully mopped to | |||
| deck w/asphalt primer (See Tech Specs.) |
| 2189 | Install Mod bit rfng, SBS mod, gran surf cap sheet, poly rein, mppd, | 1,040 | SF |
| 160 mils w/base sheet, #15 Glass Fiber Felt fully mopped to | |||
| deck w/asphalt primer (See Tech Specs.) |
| 2190 | Remove and Dispose Mod bit, SBS mod, smooth surf cap sheet, glass fiber rein, mppd, | 1,040 | SF |
| 160 mils w/base sheet, #15 Glass Fiber Felt fully mopped to | |||
| deck w/asphalt primer (See Tech Specs.) |
| 2191 | Install Mod bit, SBS mod, smooth surf cap sheet, glass fiber rein, mppd, | 1,040 | SF |
| 160 mils w/base sheet, #15 Glass Fiber Felt fully mopped to | |||
| deck w/asphalt primer (See Tech Specs.) |
| 2192 | Remove and Dispose Mod bit, APP mod, gran surface cap sheet, poly, | 1,040 | SF |
| rein, torched, 180 mils w/base sheet, #15 Glass Fiber Felt fully mopped to | |||
| deck w/asphalt primer (See Tech Specs.) |
| 2193 | Install Mod bit, APP mod, gran surface cap sheet, poly rein, | 1,040 | SF |
| torched, 180 mils w/base sheet, #15 Glass Fiber Felt fully mopped to | |||
| deck w/asphalt primer (See Tech Specs.) |
| 2194 | Remove and Dispose Mod bit, APP mod, smooth surf cap sheet, poly rein, torched, 160 mils w/base sheet, #15 Glass Fiber Felt fully mopped to | 1,040 | SF |
| deck w/asphalt primer (See Tech Specs.) |
| 2195 | Install Mod bit, APP mod, smooth surf cap sheet, poly rein, torched, | 1,040 | SF |
| 160 mils w/base sheet, #15 Glass Fiber Felt fully mopped to | |||
| deck w/asphalt primer (See Tech Specs.) |
2196 Remove and Dispose Roof coatings, asphalt primer, 5 gallon (See Tech Specs.) 20,000 SF
2197 Install Roof coatings, asphalt primer, 5 gallon (See Tech Specs.) 20,000 SF
2198 Remove and Dispose Bituminous asphalt coating, with fibers, troweled on, 1/2" thick (See Tech Specs.) 2,600 SF
| 2199 | Install Bituminous asphalt coating, with fibers, troweled on, 1/2" thick | 2,600 | SF |
| (See Tech Specs.) |
2200 Remove and DisposeBuilt-up rfg,asph fl CT,ctd gl fbr base sht,3 plies,on nailable dks (See Tech Specs.) 2,600 SF
| 2201 | Install Built-up rfg,asph fl CT,ctd gl fbr base sht,3 plies,on nailable dks | 2,600 | SF |
| (See Tech Specs.) |
2202 Remove and Dispose Built-up rfg,asph fl CT,ctd gl fbr base sht,4ply gl fbr felt,mopped (See Tech Specs.) 2,600 SF
| 2203 | Install Built-up rfg,asph fl CT,ctd gl fbr base sht,4ply gl fbr felt,mopped | 2,600 | SF |
| (See Tech Specs.) |
2204 Remove and Dispose Rubber coating, silicone or stearate, sprayed on CMU, 2 coats (See Tech Specs.) 1,040 SF
| 2205 | Install Rubber coating, silicone or stearate, sprayed on CMU, 2 coats | 1,040 | SF |
| (See Tech Specs.) |
2206 Remove and Dispose Pitch Pockets, side extenders, 6" (See Tech Specs.) 18 EA
2207 Install Pitch Pockets, side extenders, 6" (See Tech Specs.) 18 EA
2208 Remove and Dispose Pitch Pockets, adjustable, 4" to 7", welded corners, 4" deep (See Tech Specs.) 18 EA
| 2209 | Install Pitch Pockets, adjustable, 4" to 7", welded corners, 4" deep | 18 | EA |
| (See Tech Specs.) |
2210 Remove and Dispose Walkway for BUR, asph impregnated, 3' x 3' x 3/4" thk (See Tech Specs.) 700 SF
2211 Install Walkway for BUR, asph impregnated, 3' x 3' x 3/4" thk (See Tech Specs.) 700 SF
2212 Remove and Dispose Caulking & sealants, polyurethane, 1 or 2 component, bulk (See Tech Specs.) 90 LF
| 2213 | Install Caulking & sealants, polyurethane, 1 or 2 component, bulk | 90 | LF |
| (See Tech Specs.) |
2214 Remove and Dispose Caulking and sealants, silicone rubber, cartridges (See Tech Specs.) 90 LF
| 2215 | Install Caulking and sealants, silicone rubber, cartridges (See Tech | 90 | LF |
| Specs.) |
2216 Remove and Dispose Caulking and sealants, resin epoxy coating, 2 component, heavy duty (See Tech Specs.) 90 LF
| 2217 | Install Caulking and sealants, resin epoxy coating, 2 component, heavy | 90 | LF |
| duty (See Tech Specs.) |
2218 Remove and Dispose Caulking and sealants, neoprene gaskets, closed cell, 1/4" x 3/4" (See Tech Specs.) 90 LF
| 2219 | Install Caulking and sealants, neoprene gaskets, closed cell, 1/4" x 3/4" | 90 | LF |
| (See Tech Specs.) |
2220 Remove and Dispose Framing, miscellaneous, nailers, treated, wood construction, 2" x 6" (See Tech Specs.) 90 LF
| 2221 | Install Framing, miscellaneous, nailers, treated, wood construction, 2" x 6" | 90 | LF |
| (See Tech Specs.) |
2222 Remove and Dispose Framing, miscellaneous, nailers, treated, wood construction, 2" x 4" (See Tech Specs.) 90 LF
| 2223 | Install Framing, miscellaneous, nailers, treated, wood construction, 2" x 4" | 90 | LF |
| (See Tech Specs.) |
2224 Remove and Dispose Framing, miscellaneous, nailers, treated, wood construction, 2" x 8" (See Tech Specs.) 90 LF
| 2225 | Install Framing, miscellaneous, nailers, treated, wood construction, 2" x 8" | 90 | LF |
| (See Tech Specs.) |
2226 Remove and Dispose Roof deck insul, polyisocyanurate, 2#/CF density, 2" thk R14.29 (See Tech Specs.) 5,000 SF
| 2227 | Install Roof deck insul, polyisocyanurate, 2#/CF density, 2" thk R14.29 | 5,000 | SF |
| (See Tech Specs.) |
| 2228 | Remove and Dispose Roof deck insulation, polyisocyanurate 2#/CF | 5,000 | SF |
| density, tapered for drainage (See Tech Specs.) |
| 2229 | Install Roof deck insulation, polyisocyanurate 2#/CF density, | 5,000 | SF |
| tapered for drainage (See Tech Specs.) |
2230 Remove and Dispose Roof deck insulation, expanded polystyrene, 2" thick R7.69 (See Tech Specs.) 5,000 SF
| 2231 | Install Roof deck insulation, expanded polystyrene, 2" thick R7.69 | 5,000 | SF |
| (See Tech Specs.) |
2232 Remove and Dispose Roof deck insulation, expanded polystyrene, tapered for drainage (See Tech Specs.) 880 SF
| 2233 | Install Roof deck insulation, expanded polystyrene, tapered for drainage | 880 | SF |
| (See Tech Specs.) |
| 2234 | Remove and Dispose Roof deck insul., extruded polystyrene, 60 PSI | 4,000 | SF |
| comp. strength, 2" thick R10 (See Tech Specs.) |
| 2235 | Install Roof deck insul., extruded polystyrene, 60 PSI comp. | 4,000 | SF |
| strength, 2" thick R10 (See Tech Specs.) |
2236 Remove and Dispose Roof deck insul., extruded polystyrene, 60 PSI comp. strgth., tapered (See Tech Specs.) 1,040 SF
| 2237 | Install Roof deck insul., extruded polystyrene, 60 PSI comp. strgth., | 1,040 | SF |
| tapered (See Tech Specs.) |
2238 Remove and Dispose Roof hatch, 2'-6" x 3', w/curb, 1" fbgls insul, galv stl curb/cover (See Tech Specs.) 1 EA
| 2239 | Install Roof hatch, 2'-6" x 3', w/curb, 1" fbgls insul, galv stl curb/cover | 1 | EA |
| (See Tech Specs.) |
2240 Remove and Dispose Skylight, insulated safety glass with aluminum frame (See Tech Specs.) 260 SF
2241 Install Skylight, insulated safety glass with aluminum frame (See Tech Specs.) 160 SF
2242 Remove and Dispose Ladder, steel, 20" wide, bolted to concrete, with cage (See Tech Specs.) 70 VLF
2243 Install Ladder, steel, 20" wide, bolted to concrete, with cage (See Tech Specs.) 70 VLF
2244 Remove and DisposeLadder, steel, 20" wide, bolted to concrete, w/o cage (See Tech Specs.) 70 VLF
2245 Install Ladder, steel, 20" wide, bolted to concrete, w/o cage (See Tech Specs.) 70 VLF
2246 Replace Insulation/finish syst, field applied, 1 inch (See Tech Specs.) 520 SF
2247 Replace Insulation/finish syst, field applied, 2 inch (See Tech Specs.) 260 SF
2248 Replace Insulation/finish syst, field applied, 3 inch (See Tech Specs.) 260 SF
2249 Replace Ductwork, galv steel, 500-1000 lb, 12"-14"h, 18"w (See Tech Specs.) 90 LB
2250 Replace Ductwork, galv steel, 500-1000 lb, 12"-14"h, 24"w (See Tech Specs.) 90 LB
2251 Replace Ductwork, galv steel, 500-1000 lb, 12"-14"h, 48"w (See Tech Specs.) 90 LB
2252 Pipe, copper, 3/8" dia., type K (See Tech Specs.) 160 LF
2253 Pipe insulation, 3/8" copper pipe, rubber tubing (See Tech Specs.) 160 LF
2254 Vent and Pipe Replacement, PVC schedule 40, 2" dia. (See Tech Specs.) 18 LF
2255 Vent and Pipe Replacement, PVC schedule 40, 3" dia. (See Tech Specs.) 18 LF
2256 Vent and Pipe Replacement, PVC schedule 40, 4" dia. (See Tech Specs.) 18 LF
2257 HVAC demo, Mech equipment (See Tech Specs.) 2,000 LBS
2258 Air cooled condenser, 2 tons, reinstallation (See Tech Specs.) 6 EA
2259 Air cooled condenser, 16 tons,reinstallation (See Tech Specs.) 6 EA
2260 Roof top unit, 7.5 tons, single zone, reinstallation (See Tech Specs.) 6 EA
2261 Replace Wire, 600 volt, type THW, copper, stranded, #12 (See Tech Specs.) 200 LF
2262 Replace Wire, 600 volt, type THW, copper, solid, #12 (See Tech Specs.) 200 LF
2263 Replace Wire, 600 volt, type THW, copper, stranded, #10 (See Tech Specs.) 200 LF
2264 Replace Wire, 600 volt, type THW, copper, solid, #10 (See Tech Specs.) 200 LF
| 2265 | Replace Wire, 600 volt, type THW, copper, stranded, #8 (See Tech | 200 | LF |
| Specs.) |
| 2266 | Replace Wire, 600 volt, type THW, copper, stranded, #6 (See Tech | 200 | LF |
| Specs.) |
2267 ReplaceWire, 600 volt, type THW, copper, stranded, #4 (See Tech Specs.) 200 LF
| 2268 | Replace Wire, 600 volt, type THW, copper, stranded, #3 (See Tech | 200 | LF |
| Specs.) |
| 2269 | Replace Wire, 600 volt, type THW, copper, stranded, #2 (See Tech | 200 | LF |
| Specs.) |
| 2270 | Replace Wire, 600 volt, type THW, copper, stranded, #1 (See Tech | 200 | LF |
| Specs.) |
2271 Replace Wire, 600 volt, type THWN-THHN, copper, stranded, #12 (See Tech Specs.) 200 LF
2272 Replace Wire, 600 volt, type THWN-THHN, copper, solid, #12 (See Tech Specs.) 200 LF
2273 Replace Wire, 600 volt, type THWN-THHN, copper, stranded, #10 (See Tech Specs.) 200 LF
2274 Replace Wire, 600 volt, type THWN-THHN, copper, solid, #10 (See Tech Specs.) 200 LF
2275 Replace Wire, 600 volt, type THWN-THHN, copper, stranded, #8 (See Tech Specs.) 200 LF
2276 Replace Wire, 600 volt, type THWN-THHN, copper, stranded, #6 (See Tech Specs.) 200 LF
2277 Replace Wire, 600 volt, type THWN-THHN, copper, stranded, #4 (See Tech Specs.) 200 LF
2278 Replace Cond to 15' H,incl 2 termn,2 elb&11 bm CLP per 100',galv stl,1/2" dia (See Tech Specs.) 100 LF
2279 Replace Cond to 15' H,incl 2 termn,2 elb&11 bm CLP per 100',galv stl,3/4" dia (See Tech Specs.) 100 LF
| 2280 | Replace Cond to 15' H,incl 2 termn,2 elb&11 bm CLP per 100',galv stl,1" | 100 | LF |
| dia (See Tech Specs.) |
2281 Replace Cond to 15' H,incl 2 termn,2 elb&11 bm CLP per 100',galv stl,1-1/4"dia (See Tech Specs.) 100 LF
2282 Replace Cond to 15' H,incl 2 termn,2 elb&11 bm CLP per 100',galv stl,1-1/2"dia (See Tech Specs.) 100 LF
| 2283 | Replace Cond to 15' H,incl 2 termn,2 elb&11 bm CLP per 100',galv stl,2" | 100 | LF |
| dia (See Tech Specs.) |
2284 Replace Cond to 15' H,incl 2 termn,2 elb&11 bm CLP per 100',galv stl,2-1/2"dia (See Tech Specs.) 100 LF
| 2285 | Replace Cond to 15' H,incl 2 termn,2 elb&11 bm CLP per 100',galv stl,3" | 100 | LF |
| dia (See Tech Specs.) |
2286 Replace Cond to 15' H,incl 2 termn,2 elb&11 bm CLP per 100',galv stl,3-1/2"dia (See Tech Specs.) 100 LF
| 2287 | Relace Cond to 15' H,incl 2 termn,2 elb&11 bm CLP per 100',galv stl,4" | 100 | LF |
| dia (See Tech Specs.) |
2288 Replace Safety switches, heavy duty, 240 volt, 3 pole NEMA 1 fusible, 30 amp (See Tech Specs.) 8 EA
2289 Replace Safety switches, heavy duty, 240 volt, 3 pole NEMA 1 fusible, 60 amp (See Tech Specs.) 8 EA
2290 Replace Safety switches, heavy duty, 240 volt, 3 pole NEMA 1 fusible, 100 amp (See Tech Specs.) 8 EA
| 2291 | Replace Wire, 600 volt, type THW, copper, stranded, 1/0 (See Tech | 100 | LF |
| Specs.) |
| 2292 | Replace Wire, 600 volt, type THW, copper, stranded, 2/0 (See Tech | 100 | LF |
| Specs.) |
| 2293 | Replace Wire, 600 volt, type THW, copper, stranded, 3/0 (See Tech | 100 | LF |
| Specs.) |
| 2294 | Replace Wire, 600 volt, type THW, copper, stranded, 4/0 (See Tech | 100 | LF |
| Specs.) |
2295 Remove & dispose PUF or Built-up Roofing w/Asbestos Mastic (ACM) 100 SF
2001 Grand Total
File details come from the government source that posted it. Updated .