PN70551_DESIGN COMPLETE_DWG-am-0002-Part5.pdf
PDF 20 MB Posted
- Attached to
- FY22 Military Construction Army (MCA) 070551 Child Development Center, Schofield Barracks, Oahu, Hawaii
- Solicitation number
- W9128A22R0020
About this file
This document announces a solicitation for the construction of a Child Development Center at Schofield Barracks in Hawaii. The U.S. Army Corps of Engineers, Honolulu District intends to issue a Lowest Price Technically Acceptable Request for Proposal for the design and construction of a 37,300 square foot Child Development Center building, along with 38,311 square feet of playground area and 146 parking spaces. The project scope includes site development, utilities, lighting, paving, and storm drainage. The performance period is 1,237 calendar days from notice to proceed, with a project magnitude between $25-50 million. Proposals will be evaluated on experience, past performance, technical approach, and price, with award going to the best value. Offerors must register in SAM and the successful contractor is expected to subcontract to the maximum extent practicable with small, small disadvantaged, women-owned, HUBZone, veteran-owned, and service disabled veteran-owned small businesses.
View the file
Other files
Show all 33
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
WC-1
1/2" DHW
1 1/2" DCW
1/2" DHWR
LAV-1
3" DCW
2" DHW
3/4" DHWR
3" DCW
2 1/2" DHW
3/4" DHWR
4" DCW
2 1/2" DHW
1" DHWR
4" DCW
2 1/2" DHW
120°F
WC-1
WC-1
EWC-1
WC-5
LAV-2
WC-3
LAV-1
LAV-1
1/2" DHWR
140°F
3/4" DHW
140°F
3/4" DHWR
120°F
2" DHW
120°F
2 1/2" DCW
3/4" DHW
3/4" DCW
3/4" DHWR
2" DHW
2 1/2" DCW
CONT'D ON P-915
CONT'D ON P-914
1/2" DCW
1/2" DHW
1 1/2" DCW 1/2" DHWR
1/2" DHW
1/2" DCW
1/2" DHWR
1 1/4" DHW
2" DCW
2 1/2" DCW
1 1/4" DHW
3/4" DHW
1" DCW
/2
D C
W
2" DCW
3/4" DHW
1/2" DHWR
1-1/2" DCW
1/2" DCW
1/2" DHWR
1 1/4" DHW
2" DCW
1/2" DHWR
1 1/4" DHW
2" DCW
1 1/2" DCW
1/2" DCW
TP-9
3/4" TO TP-9
LAV-1
1/2" DHW
PROVIDE OFFSET FOR I-BEAM
1/2" D
HW
R
PROVIDE OFFSET
FOR I-BEAM
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
KEY PLAN
A B C
D
E
P L O
T D
A T
E
F
IL
E P
A T
H
C
R e v it P ro je c ts
\1 M
C e n tr a l_ b fo n s e c a b u rn s m c d .c o m
.r v t
/2
/2
:5
:0
P
M
P-913
R
IS
E R
D
IA
G R
A M
D
O M
E S
T
IC
W A
T E
R
A R
E A
B
S C
H O
F
IE
L D
B A
R R
A C
K S
H
A W
A
II
H O
N O
L U
L U
D
IS
T R
IC
T
F T
S
H A
F T
E R
H
A W
A
II
H O
'O H
U I'I
A
J V
B .F
O N
S E
C A
T .S
A B
IN
A
S
D .G
R A
M E
R
/1
/2
D E
S
IG
N C
O M
P L E
T E
S U
B M
IT
T
A L
F Y
M
C A
P N
C
H
IL
D D
E V
E L O
P M
E N
T C
E N
T E
R
B
IS
H
O P
S T
S
U
IT
E
H O
N O
L U
L U
H A
W A
II
NOT TO SCALEA2
AREA B DOMESTIC WATER RISER DIAGRAM
UP
DN
N
CONT'D ON P-912
A1
P-916
A1
P-918
A1
P-916
GENERAL NOTES:
1. FOR PLUMBING LEGENDS, NOTES AND ABBREVIATIONS,
SEE SHEET-P-001.
2. PIPE SIZES TO INDIVIDUAL FIXTURES ARE SHOWN ON
THE RISER DIAGRAMS
3. FOR TRAPEZE PIPE SUPPORT DETAIL, SEE K7/P-503.
4. FOR CLEVIS HANGER DETAIL, SEE J16/P-503.
5.27.22 Replaces Drawings Posted in SAM.gov on 6/8/2022 In Its Entirety
(Am-0002)
TP-10
LT-1
WM-1
WM-1
WM-1
HS-2
WH-1 HS-2
WC-3
WC-2
DF-2
LAV-6
LAV-5
HB-1
TMV-01
CP-1
CP-2
EWH-1
EWH-2
EWH-3
WC-1
LAV-1
1/2" DCW
1/2" DHW1 1/2" DCW
WH-1
BP-01
2" DCW
1 1/4" DHW
TP-19
1 1/4" DCW
1" DHW
3/4" DHW
1 1/4" DCW
1" DHW
3/4" DCW
1/2" DCW
3/4" DHW
3/4" DCW
3/4" DHW
4" DCW
2 1/2" DHW
120°F
1" DHWR
2 1/2" DHW
140°F
1" DHWR
140°F
3/4" DCW
/4
D
C W
1 1/4" D
CW
D C
W
3/4" DCW
1 1/2" DHW
4" DCW
2 1/2" DHW
120°F
1" DHWR
120°F
1/2" DHWR
3/4" DHW
140°F
1 1/2" DHW
1 1/2" DCW
HS-5
1" DCW
1/2" DHWR
120°F 1/2" DHW
120°F
2 1/2" DHW
140°F
BFP-1
EWH-1
TP-11
WH-1
3/4" D
CW
CONTINUATION
TO CHILLED
WATR SYSTEM
MAKEUP
1 1/4" D
CW
EES-1
SEE HVAC PLANS FOR
REQUIREMENTS
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
KEY PLAN
A B C
D
E
P L O
T D
A T
E
F
IL
E P
A T
H
C
R e v it P ro je c ts
\1 M
C e n tr a l_ b fo n s e c a b u rn s m c d .c o m
.r v t
/2
/2
:5
:0
P
M
P-914
R
IS
E R
D
IA
G R
A M
D
O M
E S
T
IC
W A
T E
R
A R
E A
C
S C
H O
F
IE
L D
B A
R R
A C
K S
H
A W
A
II
H O
N O
L U
L U
D
IS
T R
IC
T
F T
S
H A
F T
E R
H
A W
A
II
H O
'O H
U I'I
A
J V
B .F
O N
S E
C A
T .S
A B
IN
A
S
D .G
R A
M E
R
/1
/2
D E
S
IG
N C
O M
P L E
T E
S U
B M
IT
T
A L
F Y
M
C A
P N
C
H
IL
D D
E V
E L O
P M
E N
T C
E N
T E
R
B
IS
H
O P
S T
S
U
IT
E
H O
N O
L U
L U
H A
W A
II
NOT TO SCALEA3
AREA C DOMESTIC WATER RISER DIAGRAM
UP
DN
N
UP
DN
N
SEE CIVIL PLANS FOR CONTINUATION
CONT'D ON P-913
A1
P-920
A1
P-918
1 FOR DOMESTIC WATER HEATING SYSTEM DIAGRAM, SEE
A1/P-502.
KEYED NOTES:
GENERAL NOTES:
1. FOR PLUMBING LEGENDS, NOTES AND ABBREVIATIONS,
SEE SHEET-P-001.
2. PIPE SIZES TO INDIVIDUAL FIXTURES ARE SHOWN ON
THE RISER DIAGRAMS
3. FOR TRAPEZE PIPE SUPPORT DETAIL, SEE K7/P-503.
4. FOR CLEVIS HANGER DETAIL, SEE J16/P-503.
A10
P-504
5.27.22
WC-1
LAV-1
1/2" DHW
1/2" DCW
WHA-B
1 1/2" DCW
1/2" DCW
1 1/2" DCW
1/2" DHW
1/2" DHWR
2" DCW
1 1/4" DHW
3/4" DHWR
2 1/2" DCW
3/4" DHWR
2" DHW
2 1/2" DCW
WHA-A
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
KEY PLAN
A B C
D
E
P L O
T D
A T
E
F
IL
E P
A T
H
C
R e v it P ro je c ts
\1 M
C e n tr a l_ b fo n s e c a b u rn s m c d .c o m
.r v t
/2
/2
:5
:1
P
M
P-915
R
IS
E R
D
IA
G R
A M
D
O M
E S
T
IC
W A
T E
R
A R
E A
D
A R
E A
E
S C
H O
F
IE
L D
B A
R R
A C
K S
H
A W
A
II
H O
N O
L U
L U
D
IS
T R
IC
T
F T
S
H A
F T
E R
H
A W
A
II
H O
'O H
U I'I
A
J V
B .F
O N
S E
C A
T .S
A B
IN
A
S
D .G
R A
M E
R
/1
/2
D E
S
IG
N C
O M
P L E
T E
S U
B M
IT
T
A L
F Y
M
C A
P N
C
H
IL
D D
E V
E L O
P M
E N
T C
E N
T E
R
B
IS
H
O P
S T
S
U
IT
E
H O
N O
L U
L U
H A
W A
II
NOT TO SCALEA1
AREA D & AREA E DOMESTIC WATER RISER DIAGRAM
UP
DN
N
CONT'D ON P-913
ISOLATION VALVES
A1
P-918
A1
P-919
A1
P-918
A1
P-919
A1
P-918
GENERAL NOTES:
1. FOR PLUMBING LEGENDS, NOTES AND ABBREVIATIONS,
SEE SHEET-P-001.
2. PIPE SIZES TO INDIVIDUAL FIXTURES ARE SHOWN ON
THE RISER DIAGRAMS
3. FOR TRAPEZE PIPE SUPPORT DETAIL, SEE K7/P-503.
4. FOR CLEVIS HANGER DETAIL, SEE J16/P-503.
5.27.22
HS-2
WH-1
HS-2
LAV-3
WC-2
WC-2
HS-1
LAV-4
DF-1
/4
D
C W
/2
D
C W
/2
D
H W
/2
D
C W
/2
D
H W
/2
D
C W
/2
D
H W1
/2
D
C W
/2
D C
W
1" DHW
1 1/4" DCW
2" DCW
1 1/4" DHW
1" DCW
1" DHW
1" DCW
1" DHW
1/2" DHW
R
ROOM ISOLATION VALVES. PROVIDE ACCESS PANEL IN CEILING
WHA-B
WHA-A
TP-2
1/2" DCW
1/2" DHW
1/2" DCW
1/2" DHW
1/2" DCW
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
P L O
T D
A T
E
F
IL
E P
A T
H
C
R e v it P ro je c ts
\1 M
C e n tr a l_ b fo n s e c a b u rn s m c d .c o m
.r v t
/2
/2
:5
:1
P
M
P-916
E N
L A
R G
E D
R
IS
E R
D
IA
G R
A M
D
O M
E S
T
IC
W A
T E
R
S C
H O
F
IE
L D
B A
R R
A C
K S
H
A W
A
II
H O
N O
L U
L U
D
IS
T R
IC
T
F T
S
H A
F T
E R
H
A W
A
II
H O
'O H
U I'I
A
J V
B .F
O N
S E
C A
T .S
A B
IN
A
S
D .G
R A
M E
R
/1
/2
D E
S
IG
N C
O M
P L E
T E
S U
B M
IT
T
A L
F Y
M
C A
P N
C
H
IL
D D
E V
E L O
P M
E N
T C
E N
T E
R
B
IS
H
O P
S T
S
U
IT
E
H O
N O
L U
L U
H A
W A
II
NOT TO SCALEA3
TYPICAL SINGLE TOILET ROOM DOMESTIC WATER RISER DIAGRAM
WALL HYDRANT ISOLATION VALVE.
PROVIDE ACCESS PANEL IN BUILDING
UP
DN
N
1 FOR TYPICAL PONY WALL PIPE ROUTING, SEE PLUMBING
SECTION A2/P-302 & A4/P-302.
2 CONT'D TO MAIN PIPING IN CORRIDOR.
3 FOR TRAP PRIMER DETAIL, SEE H14/P-502 OR E1/P-501.
PROVIDE ACCESS PANEL ON WALL AT TP LOCATION.
INSTALL PER MANU. REQUIREMENTS. REFER TO TRAP
PRIMER SCHEDULE ON P-601 FOR DRAINS SERVED.
4 DHW, DHWR, DCW BRANCH PIPING FROM CORRIDOR TO
ROOMS DROP TO 9'3" BOP EL.
KEYED NOTES:
GENERAL NOTES:
1. FOR PLUMBING LEGENDS, NOTES AND ABBREVIATIONS,
SEE SHEET-P-001.
2. PIPE SIZES TO INDIVIDUAL FIXTURES ARE SHOWN ON
THE RISER DIAGRAMS
3. FOR TRAPEZE PIPE SUPPORT DETAIL, SEE K7/P-503.
4. FOR CLEVIS HANGER DETAIL, SEE J16/P-503.
5.27.22
/4
D
C W
/4
D
H W
/4
D
C W
/4
D
H W
/4
D
C W
/4
D
H W
D C
W2
D C
W 1 1/2" DCW
2" DCW
2" DCW
DF-1
HS-1
WC-2
WC-2
LAV-4
LAV-3
HS-2
HS-2
HS-2
HS-2
1/2" DCW
1/2" DHW
1/2" DCW
1" DCW
1" DHW
1" DHW
1" DCW
1" DHW
1" DCW
WHA-C
WHA-B
TP-19
LAV-3
WC-2
WC-2
DF-1
HS-1
ROOM ISOLATION VALVES.
PROVIDE ACCESS PANEL IN CEILING
1 1/2" DHW
1 1/2" DCW
1 1/4" DHW
1/2" DHW
R1-1/2" DCW
1/2" DCW
1/2" DHW
1/2" DCW
1/2" DHW
1/2" DHW
1/2" DCW
1/2" DCW
1/2" DCW
1/2" DHW
1/2" DCW
1" DHW
1" DCW
1/2" DCW
1/2" DHW
CIRCUIT SETTER
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
P L O
T D
A T
E
F
IL
E P
A T
H
C
R e v it P ro je c ts
\1 M
C e n tr a l_ b fo n s e c a b u rn s m c d .c o m
.r v t
/2
/2
:5
:1
P
M
P-917
E N
L A
R G
E D
R
IS
E R
D
IA
G R
A M
D
O M
E S
T
IC
W A
T E
R
S C
H O
F
IE
L D
B A
R R
A C
K S
H
A W
A
II
H O
N O
L U
L U
D
IS
T R
IC
T
F T
S
H A
F T
E R
H
A W
A
II
H O
'O H
U I'I
A
J V
B .F
O N
S E
C A
T .S
A B
IN
A
S
D .G
R A
M E
R
/1
/2
D E
S
IG
N C
O M
P L E
T E
S U
B M
IT
T
A L
F Y
M
C A
P N
C
H
IL
D D
E V
E L O
P M
E N
T C
E N
T E
R
B
IS
H
O P
S T
S
U
IT
E
H O
N O
L U
L U
H A
W A
II
NOT TO SCALEA1
TYPICAL BACK TO BACK TOILET ROOM DOMESTIC WATER RISER DIAGRAM
UP
DN
N
1 FOR TYPICAL PONY WALL PIPE ROUTING, SEE PLUMBING
SECTION A2/P-302 & A4/P-302.
2 DHW, DHWR, DCW BRANCH PIPING FROM CORRIDOR TO
ROOMS DROP TO 9'3" BOP EL.
3 CONT'D TO MAIN PIPING IN CORRIDOR.
4 FOR TRAP PRIMER DETAIL, SEE H14/P-502 OR E1/P-501.
PROVIDE ACCESS PANEL ON WALL AT TP LOCATION.
INSTALL PER MANU. REQUIREMENTS. REFER TO TRAP
PRIMER SCHEDULE ON P-601 FOR DRAINS SERVED.
KEYED NOTES:
GENERAL NOTES:
1. FOR PLUMBING LEGENDS, NOTES AND ABBREVIATIONS,
SEE SHEET-P-001.
2. PIPE SIZES TO INDIVIDUAL FIXTURES ARE SHOWN ON
THE RISER DIAGRAMS
3. FOR TRAPEZE PIPE SUPPORT DETAIL, SEE K7/P-503.
4. FOR CLEVIS HANGER DETAIL, SEE J16/P-503.
5.27.22
WC-3
WC-4
DF-2
LAV-6
HS-1
LAV-1
HS-2
HS-2
LAV-5
1/2" DCW
1/2" DHW
/2
D
C W
/2
D
H W
1 1/4" DCW
1" DHW
/2
D C
W
/2
D
C W 1
/2
D C
W
2" DCW
2" DCW
2" DCW
1 1/4" DHW
TP-13
1 1/4" DCW
1" DHW
1" DHW
1 1/2" DCW
3/4" DHW
1 2
WHA-C
WHA-B
/2
D
C W
/2
D
H W
CIRCUIT SETTER
1/2" DCW
1/2" DHW
120°F
1/2" DHW
R
PROVIDE OFFSET FOR
DUCTWORK WHERE
APPLICABLE
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
P L O
T D
A T
E
F
IL
E P
A T
H
C
R e v it P ro je c ts
\1 M
C e n tr a l_ b fo n s e c a b u rn s m c d .c o m
.r v t
/2
/2
:5
:2
P
M
P-918
E N
L A
R G
E D
R
IS
E R
D
IA
G R
A M
D
O M
E S
T
IC
W A
T E
R
S C
H O
F
IE
L D
B A
R R
A C
K S
H
A W
A
II
H O
N O
L U
L U
D
IS
T R
IC
T
F T
S
H A
F T
E R
H
A W
A
II
H O
'O H
U I'I
A
J V
B .F
O N
S E
C A
T .S
A B
IN
A
S
D .G
R A
M E
R
/1
/2
D E
S
IG
N C
O M
P L E
T E
S U
B M
IT
T
A L
F Y
M
C A
P N
C
H
IL
D D
E V
E L O
P M
E N
T C
E N
T E
R
B
IS
H
O P
S T
S
U
IT
E
H O
N O
L U
L U
H A
W A
II
NOT TO SCALEA3
TYPICAL SINGLE TOILET ROOM DOMESTIC WATER RISER DIAGRAM
UP
DN
N
1 CONT'D TO MAIN PIPING IN CORRIDOR.
2 DHW, DHWR, DCW BRANCH PIPING FROM CORRIDOR TO
ROOMS DROP TO 9'3" BOP EL.
3 STAFF TOILET PLUMBING FIXTURES AND PIPING ARE
TYPICAL FOR ACTIVITY ROOMS 121 AND 162 ONLY.
4 FOR TRAP PRIMER DETAIL, SEE H14/P-502 OR E1/P-501.
PROVIDE ACCESS PANEL ON WALL AT TP LOCATION.
INSTALL PER MANU. REQUIREMENTS. REFER TO TRAP
PRIMER SCHEDULE ON P-601 FOR DRAINS SERVED.
KEYED NOTES:
GENERAL NOTES:
1. FOR PLUMBING LEGENDS, NOTES AND ABBREVIATIONS,
SEE SHEET-P-001.
2. PIPE SIZES TO INDIVIDUAL FIXTURES ARE SHOWN ON
THE RISER DIAGRAMS
3. FOR TRAPEZE PIPE SUPPORT DETAIL, SEE K7/P-503.
4. FOR CLEVIS HANGER DETAIL, SEE J16/P-503.
5.27.22
WC-3
WC-4
WC-4
WC-3
HS-2
HS-2HS-2
HS-2
DF-2
HS-1
1 1/4" D
CW
3/4" D
HW
/4
D
C W
/4
D
H W
/4
D
H W
/4
D
C W
1 1/2" D
CW
1 1/4" D
HW
2" D
CW
1 1/2" D
HW
1/2" D
HW
R
1" DHW
1 1/4" DCW
1" DHW
1 1/4" DCW
1 1/4" D
CW
1" D
HW
3/4" DCW
1/2" DCW
1/2" DCW
3/4" DCW
3/4" DCW
1/2" DHW
1/2" DHW
1 1/4" D
CW
1" D
HW
1/2" DCW
1/2" DHW
1/2" DCW
1/2" DHW
3/4" DHW
TP-15
ISOLATION VALVES
/4
D
C W
WH-1
LAV-5
LAV-6
DF-2
LAV-5
HS-1
LAV-6
1/2" DHW 1/2" DHW
1/2" DCW
1/2" DHW
1/2" DHW
1/2" DCW
1/2" DHW1/2" DCW
2 3
WHA-B
WHA-C
2" DCW
2" DCW
CIRCUIT SETTER
1 1/2" DCW
1 1/2" DCW
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
P L O
T D
A T
E
F
IL
E P
A T
H
C
R e v it P ro je c ts
\1 M
C e n tr a l_ b fo n s e c a b u rn s m c d .c o m
.r v t
/2
/2
:5
:2
P
M
P-919
E N
L A
R G
E D
R
IS
E R
D
IA
G R
A M
D
O M
E S
T
IC
W A
T E
R
S C
H O
F
IE
L D
B A
R R
A C
K S
H
A W
A
II
H O
N O
L U
L U
D
IS
T R
IC
T
F T
S
H A
F T
E R
H
A W
A
II
H O
'O H
U I'I
A
J V
B .F
O N
S E
C A
T .S
A B
IN
A
S
D .G
R A
M E
R
/1
/2
D E
S
IG
N C
O M
P L E
T E
S U
B M
IT
T
A L
F Y
M
C A
P N
C
H
IL
D D
E V
E L O
P M
E N
T C
E N
T E
R
B
IS
H
O P
S T
S
U
IT
E
H O
N O
L U
L U
H A
W A
II
NOT TO SCALEA2
ENLARGED RISER DIAGRAM - DOMESTIC WATER - PRE-K B2B
UP
DN
N
1 FOR TYPICAL PONY WALL PIPE ROUTING, SEE PLUMBING
SECTION A2/P-302 & A4/P-302.
2 CONT'D TO MAIN PIPING IN CORRIDOR.
3 DHW, DHWR, DCW BRANCH PIPING FROM CORRIDOR TO
ROOMS DROP TO 9'3" BOP EL.
4 FOR TRAP PRIMER DETAIL, SEE H14/P-502 OR E1/P-501.
PROVIDE ACCESS PANEL ON WALL AT TP LOCATION.
INSTALL PER MANU. REQUIREMENTS. REFER TO TRAP
PRIMER SCHEDULE ON P-601 FOR DRAINS SERVED.
KEYED NOTES:
GENERAL NOTES:
1. FOR PLUMBING LEGENDS, NOTES AND ABBREVIATIONS,
SEE SHEET-P-001.
2. PIPE SIZES TO INDIVIDUAL FIXTURES ARE SHOWN ON
THE RISER DIAGRAMS
3. FOR TRAPEZE PIPE SUPPORT DETAIL, SEE K7/P-503.
4. FOR CLEVIS HANGER DETAIL, SEE J16/P-503.
5.27.22
HS-4
HS-4
3/4" DCW
3/4" DCW
1/2" DHW
3/4" DCW
3/4" DHW
120°F
1/2" DHWR
140°F
1/2" DHWR
140°F
3/4" DHW
140°F
3/4" DCW
1" DHW
140°F
1/2" DHWR
1/2" DHWR
120°F
3/4" DHW
140°F
3/4" DCW
3/4" DHW
140°F
3/4" DCW
PIPING IN CORRIDOR
PIPING IN CORRIDOR
3/4" DCW
PRESSURE REDUCING VALVE
SET @ 25 PSI
4" DCW
2 1/2" DHW
120°F
1 1/2" DHW
1" DHWR
120°F
2 1/2" DHW
120°F
4" DCW
ISOLATION VALVES
3/4" DHW
3/4" DCW
WHA-B
WHA-B
WHA-C
WH-1
1" DHW
140°F
3/4" DCW
CIRCUIT SETTER
CIRCUIT SETTER
CIRCUIT SETTER
2" DCW
1 1/2" DHW
140°F
PIPING TO ACTIVITY ROOMS
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
P L O
T D
A T
E
F
IL
E P
A T
H
C
R e v it P ro je c ts
\1 M
C e n tr a l_ b fo n s e c a b u rn s m c d .c o m
.r v t
/2
/2
:5
:2
P
M
P-920
E N
L A
R G
E D
R
IS
E R
D
IA
G R
A M
D
O M
E S
T
IC
W A
T E
R
K
IT
C H
E N
S C
H O
F
IE
L D
B A
R R
A C
K S
H
A W
A
II
H O
N O
L U
L U
D
IS
T R
IC
T
F T
S
H A
F T
E R
H
A W
A
II
H O
'O H
U I'I
A
J V
B .F
O N
S E
C A
T .S
A B
IN
A
S
D .G
R A
M E
R
/1
/2
D E
S
IG
N C
O M
P L E
T E
S U
B M
IT
T
A L
F Y
M
C A
P N
C
H
IL
D D
E V
E L O
P M
E N
T C
E N
T E
R
B
IS
H
O P
S T
S
U
IT
E
H O
N O
L U
L U
H A
W A
II
NOT TO SCALEA1
ENLARGED RISER DIAGRAM - DOMESTIC WATER - KITCHEN
1 M12-UNDERCOUNTER ICE MAKER. SEE KITCHEN DRAWING
QF103.
2 M17-2 COMPARTMENT PREP SINK. SEE KITCHEN DRAWING
QF103.
3 M29-3 COMPARTMENT SINK. SEE KITCHEN DRAWING QF103.
4 M27-SCRAP SINK WITH PRE-RINSE. SEE KITCHEN DRAWING
QF103.
5 M33-DISHWASHER. SEE KITCHEN DRAWING QF103.
6 M37-SCRAP SINK WITH PRE-RINSE. SEE KITCHEN DRAWING
QF103.
7 M38-HOSE REEL WITH CONTROL BOX. SEE KITCHEN
DRAWING QF103.
8 DHW, DHWR, DCW MAIN PIPING IN CORRIDOR AT 10'2" BOP
EL.
9 DHW, DHWR, DCW BRANCH PIPING FROM CORRIDOR TO
KITCHEN TO 10'-2" BOP EL.
10 M19-TILTING SKILLET WITH DOUBLE PANTRY FAUCET. SEE
KITCHEN DRAWING QF103.
11 M33A-DISHWASHER DRAIN WATER TEMPERING & DRAIN.
SEE KITCHEN DRAWING QF103.
12 M20-COMBI-OVEN, 1-CW SUPPLY TO WATER FILTER, 1-CW
SUPPLY HI-TEMP RESISTANT PIPE/DRAINLINE. SEE KITCHEN
DRAWING QF103.
KEYED NOTES:
GENERAL NOTES:
1. FOR PLUMBING LEGENDS, NOTES AND ABBREVIATIONS,
SEE SHEET-P-001.
2. PIPE SIZES TO INDIVIDUAL FIXTURES ARE SHOWN ON
THE RISER DIAGRAMS
3. FOR TRAPEZE PIPE SUPPORT DETAIL, SEE K7/P-503.
4. FOR CLEVIS HANGER DETAIL, SEE J16/P-503.
UP
DN
N
5.27.22
HVAC LEGEND
M
CONTROL DAMPER, MOTOR
OPERATED
MANUAL BALANCE DAMPER
BD
BACKDRAFT DAMPER
AD
AD
ACCESS DOOR (AD)
ACCESS PANEL (AP)
S
AD
S
DAMPERS:
FIRE (F) -
SMOKE (S) -
FIRE SMOKE (F/S) -
AD
SECURITY BARS
FLEXIBLE DUCT CONNECTION
RECTANGLUAR ELBOW WITH
TURNING VANES
RECTANGULAR TEE WITH
TURNING VANES
RECTANGULAR RADIUS ELBOW
R RISE IN RESPECT TO AIR-FLOW
D DROP IN RESPECT TO AIR-FLOW
SQUARE OR RECTANGULAR TO
ROUND TRANSITION
SUPPLY AIR OR OUTSIDE AIR
RECTANGULAR DUCT SECTION
RETURN AIR RECTANGULAR
DUCT SECTION
EXHAUST AIR RECTANGULAR
DUCT SECTION
ROUND FLEXIBLE DUCT
(5'-0" MAX LENGTH)
SQUARE OR RECTANGULAR
SUPPLY DIFFUSER
RETURN AIR DIFFUSER
EXHAUST AIR DIFFUSER
T THERMOSTAT
CO2 CARBON DIOXIDE SENSOR
H HUMIDISTAT
LINEAR SLOT DIFFUSER
VAV- VARIABLE AIR VOLUME
TERMINAL BOX
(3'-0") FINNED TUBE RADIATION.
LENGTH OF ELEMENT SHOWN
IN PARENTHESIS
ESS EMERGENCY SHUT-OFF SWITCH
M MOTOR
FCP FAN CONTROL PANEL
AIRFLOW ARROW
BA BREATHING AIR DROP
CA COMPRESSED AIR DROP
SUPPLY AIR OR OUTSIDE AIR
ROUND DUCT SECTION
RETURN AIR ROUND DUCT
SECTION
EXHAUST AIR ROUND DUCT
SECTION
DP DIFFERENTIAL PRESSURE
SENSOR
S STATIC PRESSURE SENSOR
OCC OCCUPANCY SENSOR
ROUND & RECTANGULAR DUCT
TAKEOFF
CO CARBON MONOXIDE SENSOR
PIPE LINE ACCESSORIES
3-WAY VALVE
2-WAY VALVE
ANGLE VALVE
AV
AUTOMATIC AIR VENT
ASSEMBLY
BFP
BACKFLOW PREVENTION
ASSEMBLY
BALANCING VALVE / CIRCUIT
SETTER
BALL VALVE
BLIND FLANGE
BUTTERFLY VALVE
CHECK VALVE
FLEX CONNECTION
FLOW ARROW
FM FLOW METER
GATE VALVE
GLOBE VALVE
HOSE GATE DRAIN VALVE
IF
INSULATING FLANGE
MV
MANUAL AIR VENT ASSEMBLY
- SEE SPECIFICATIONS FOR
APPROPRIATE VALVE TYPE
M METER
M MOTORIZED CONTROL VALVE
OS&Y
OUTSIDE SCREW & YOKE VALVE
PIPE WITH HEAT TRACE
PLUG VALVE
PRESSURE GUAGE
SELF CONTAINED PRESSURE
REDUCING (REGULATING)
VALVE
PUMP
REDUCER (CONCENTRIC)
RELIEF, SAFETY OR THERMAL
RELIEF VALVE
REMOVABLE CAP
REMOVABLE PLUG
S STRAINER
SUCTION DIFFUSER
TEST CONNECTION
THERMOMETER
UNION
Y-TYPE STRAINER
SRC SPRING RETURN CLOSED BALL
VALVE
M 3 WAY MOTORIZED CONTROL
VALVE
PIPE SYMBOLS
PIPE ELBOW
PIPE DOWN
PIPE UP
PIPE CONTINUATION
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
P L O
T D
A T
E
F
IL
E P
A T
H
C
R e v it P ro je c ts
\1 M
C e n tr a l_ jh c h o ri k i.
rv t
/2
/2
:3
:2
P
M
M-001
M E
C H
A N
IC
A
L N
O T
E S
L E
G E
N D
S
Y M
B O
L S
A
B B
R E
V
IA
T
IO
N S
S C
H O
F
IE
L D
B A
R R
A C
K S
H
A W
A
II
H O
N O
L U
L U
D
IS
T R
IC
T
F T
S
H A
F T
E R
H
A W
A
II
H O
'O H
U I'I
A
J V
J C
H O
R
IK
I
J C
H O
R
IK
I
K M
O L
IN
A
/1
/2
D E
S
IG
N C
O M
P L E
T E
S U
B M
IT
T
A L
F Y
M
C A
P N
C
H
IL
D D
E V
E L O
P M
E N
T C
E N
T E
R
B
IS
H
O P
S T
S
U
IT
E
H O
N O
L U
L U
H A
W A
II
PIPELINE ABBREVIATIONS
MECHANICAL ABBREVIATIONS GENERAL NOTES:
DETAIL / ENLARGED
CALLOUT SYMBOL
A
M-001
INDICATES
LIMITS OF
DETAIL/SECTION
DETAIL/SECTION
DESIGNATOR
SHEET WHERE
DETAIL/SECTION IS
SHOWN
DETAIL/SECTION TITLE
TITLE
A1
LOCATION WHERE
DETAIL / SECTION
IS SHOWN ON
SHEET
SECTION CUT SYMBOL
A
M-001
INDICATES PERSPECTIVE
AND LIMITS OF SECTION
SECTION
DESIGNATOR
DRAWING WHERE
SECTION IS SHOWN
AIR DISTRIBUTION DEVICE
IDENTIFICATION
AIR FLOW NECK SIZE
QUANTITY
SYSTEM TYPE SPEC. TYPE
SA-A
(2)175-8Ø
1. LEGEND IS GENERAL IN NATURE AND MAY INDICATE MORE INFORMATION THAN IS APPLICABLE TO
PROJECT. SEE PLANS FOR SPECIFIC SYMBOLS AND ABBREVIATIONS.
2. PROVIDE ALL MATERIALS, VALVES, HANGERS, ETC. AND EQUIPMENT AND PERFORM ALL LABOR
REQUIRED TO INSTALL COMPLETE AND OPERABLE MECHANICAL SYSTEMS AS INDICATED ON THE
DRAWINGS, AS SPECIFIED, AND AS REQUIRED BY CODE.
3. INSTALL ALL MECHANICAL EQUIPMENT AND APPURTENANCES IN ACCORDANCE WITH
MANUFACTURERS RECOMMENDATIONS, CONTRACT DOCUMENTS, AND APPLICABLE CODES AND
REGULATIONS.
4. COORDINATE CONSTRUCTION OF ALL MECHANICAL WORK WITH STRUCTURAL, CIVIL, ELECTRICAL
WORK, ETC., SHOWN ON OTHER CONTRACT DOCUMENT DRAWINGS.
5. UNLESS OTHERWISE INDICATED MAINTAIN A MINIMUM OF 6'-8" CLEARANCE TO UNDERSIDE OF PIPES, CONDUITS, ETC., THROUGHOUT ACCESS ROUTES AND IN MECHANICAL ROOMS.
6. LOCATE ALL MECHANICAL EQUIPMENT FOR UNOBSTRUCTED ACCESS TO UNIT ACCESS PANELS, CONTROLS, AND VALVING.
7. VERIFY DIMENSIONS AND CONNECTION SIZE WITH FURNISHED EQUIPMENT.
8. ALL ELEVATIONS ARE ABOVE FINISHED FLOOR TO BOTTOM OF DUCT, PIPE, OR PIPE INSULATION
UNLESS NOTED OTHERWISE.
9. ALL DUCTWORK DIMENSIONS REFER TO INSIDE CLEAR AREA.
10. LOCATE TRANSFER AIR DUCTS AND OPENINGS 24" ABOVE HIGHEST CEILING ELEVATION UNLESS
OTHERWISE NOTED.
11. COORDINATE ALL WALL AND ROOF PENETRATIONS WITH STRUCTURAL AND ARCHITECTURAL PLANS.
12. INSTALL TEMPERATURE CONTROLS AT 48" ABOVE FINISHED FLOOR AND COORDINATE WITH OTHER
DEVICES LOCATED ON WALLS. WHERE INDICATED, PROVIDE AN ADDITIONAL SECOND TAMPER
PROOF TEMPERATURE SENSOR 12" AFF. COORDINATE WITH ARCHITECTURAL WALL FINISHES.
13. PROVIDE STRUCTURAL EQUIPMENT PADS IN ACCORDANCE WITH STRUCTURAL DRAWINGS AND
SPECIFICATIONS.
14. CONTRACTOR SHALL AIR BALANCE ALL GRILLES TO CFM'S SHOWN ON PLANS.
15. MOUNT ALL OVERHEAD MECHANICAL EQUIPMENT AND FIXTURES WEIGHING 31 POUNDS OR MORE
TO SUPPORTS THAT SHALL RESIST FORCES OF 0.5 TIMES THE EQUIPMENT WEIGHT IN ANY
HORIZONTAL DIRECTION AND 1.5 TIMES THE EQUIPMENT WEIGHT IN THE DOWNWARD DIRECTION.
FOS FUEL OIL SUPPLY
HPS HIGH PRESSURE STEAM
HWR HOT WATER RETURN
HWS HOT WATER SUPPLY
LPS LOW PRESSURE STEAM
MPS MEDIUM PRESSURE STEAM
MW MAKEUP WATER (AFTER BACKFLOW
PREVENTER)
N NITROGEN
NG NATURAL GAS
O OXYGEN
PCR PUMPED CONDENSATE RETURN
V VACUUM
BLWDN BLOWDOWN
BT BUFFER TANK
CD CONDENSATE DRAIN
CHWR CHILLED WATER RETURN
CHWS CHILLED WATER SUPPLY
CR CONDENSATE RETURN
CT CHEMICAL TREATMENT
CTB COOLING TOWER BLOWDOWN
CWR CONDENSER WATER RETURN
CWS CONDENSER WATER SUPPLY
D DRAIN
DI DEIONIZED WATER
FOR FUEL OIL RETURN
IA INSTRUMENT AIR
IH INFRARED HEATER
IN. W.C INCHES WATER COLUMN
L LOUVER
LAT LEAVING AIR TEMPERATURE
LR LONG RADIUS
LWT LEAVING WATER TEMPERATURE
MA MIXED AIR
MAT MIXED AIR TEMPERATURE
MAU MAKEUP AIR UNIT
MFR MANUFACTURER
MJ MECHANICAL JOINT
MW MAKE-UP WATER (AFTER BACKFLOW
PREVENTER)
NC NORMALLY CLOSED (FAIL POSITION)
NG NATURAL GAS
NO NORMALLY OPEN (FAIL POSITION)
OA OUTSIDE AIR
OB OPPOSED BLADE
OD OVERFLOW DRAIN
PA PRESSURIZATION AIR
PB PARALLEL BLADE
PCW PROCESS COLD WATER
PFX PLATE AND FRAME HEAT EXCHANGER
PSIA POUNDS PER SQUARE INCH ABSOLUTE
PSIG POUNDS PER SQUARE INCH GAUGE
RA RETURN AIR
RED REDUCER-REDUCING
RG REFRIGERANT HOT GAS DISCHARGE
RL REFRIGERANT LIQUID
RMJ RESTRAINED MECHANICAL JOINT
RS REFRIGERANT SUCTION
SA SUPPLY AIR
SCH SCHEDULE
SCR SPRING RETURN CLOSED
SHR SHORT RADIUS
SP STATIC PRESSURE SENSOR
SR SUPPLY REGISTER
SW SOCKET WELD
TA TRANSFER AIR
TOA TREATED OUTSIDE AIR
TOC TOP OF CONCRETE
TOD TOP OF DUCT
TOS TOP OF STEEL
V VENT
VAV VARIABLE AIR VOLUME
VFD VARIABLE FREQUENCY DRIVE
VRF VARIABLE REFRIGERANT FLOW
WB WET BULB
WE WELD END
WN WELD NECK
12"Ø ROUND DUCT DIMENSION
24x12 RECTANGULAR DUCT DIMENSION (INCHES)
ACU AIR CONDITIONING UNIT
AFF ABOVE FINISHED FLOOR
AFMS AIR FLOW MEASURING STATION
AHU AIR HANDLING UNIT
AS AIR SEPARATOR
BBO BOILER BLOW-OFF
BOD BOTTOM OF DUCT
BOP BOTTOM OF PIPE
BP BOOSTER PUMP
CCTV CLOSED-CIRCUIT TELEVISION
CFM CUBIC FEET PER MINUTE
CHEM CHEMICAL POT HEATER
CHP CHILLED WATER PUMP
CHR CHILLED WATER RETURN
CHS CHILLED WATER SUPPLY
CL CENTER LINE OF PIPE ELEVATION
CONC CONCENTRIC
COND COOLING COIL CONDENSATE DRAIN
CRAC COMPUTER ROOM AIR CONDITIONER
CU CONDENSING UNIT
CUH CABINET UNIT HEATER
CV CONTROL VALVE
DB DRY BULB
DH DEHUMIDIFIER
DN DOWN
DRG DIFFUSER, REGISTER, GRILLE
EA EXHAUST AIR
EAT ENTERING AIR TEMPERATURE
EF EXHAUST FAN
EG EXHAUST GRILLE
EL ELEVATION
ELL ELBOW
EMCS ENERGY MANAGEMENT CONTROL SYSTEM
ER AUST REGISTER
ESP EXTERNAL STATIC PRESSURE
ET EXPANSION TANK
EWT ENTERING WATER TEMPERATURE
EXIST EXISTING
FCU FAN COIL UNIT
FD FEEDWATER
FF FLAT FACED
FO FLAT OVAL
FOB FLAT ON BOTTOM
FOT FLAT ON TOP
HWB HEATING HOT WATER BOILER
HWP HEATING HOT WATER PUMP
HWR HEATING HOT WATER RETURN
HWS HEATING HOT WATER SUPPLY
I.E. INVERT ELEVATION
HVAC DESIGN CRITERIA
OUTDOOR DESIGN CONDITIONS
1.0% HUMIDITY RATIO AND MCDB (MOST STRINGENT): 128 GR/LB AT 78°F
INDOOR DESIGN CONDITIONS
OCCUPIED SPACES: 75°F (MAX ALLOWED PER ARMY CDC STANDARD IS 78°F)
CCTV/COMM ROOMS: 70°F (MAX ALLOWED PER ARMY CDC STANDARD IS 72°F)
MECH/ELEC ROOMS: 10°F ABOVE AMBIENT (ARMY CDC STANDARD REQUIRES HEATING ONLY)
5.27.22
CH-1
D
M-107 A1
M-104 A1
M-105 A1
M-106 A1
M-108 A1
M-109 A1
M-110 A1
M-111 A1
M-102 A1
M-103 A1
B
A F
EC US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
KEY PLAN
A B C
D
E
P L O
T D
A T
E
F
IL
E P
A T
H
C
R e v it P ro je c ts
\1 M
C e n tr a l_ jh c h o ri k i.
rv t
/2
/2
:3
:3
P
M
M-101
O V
E R
A L L H
V A
C
H V
A C
P
IP
IN
G
P L A
N
S C
H O
F
IE
L D
B A
R R
A C
K S
H
A W
A
II
H O
N O
L U
L U
D
IS
T R
IC
T
F T
S
H A
F T
E R
H
A W
A
II
H O
'O H
U I'I
A
J V
J C
H O
R
IK
I
J C
H O
R
IK
I
K M
O L
IN
A
/1
/2
D E
S
IG
N C
O M
P L E
T E
S U
B M
IT
T
A L
F Y
M
C A
P N
C
H
IL
D D
E V
E L O
P M
E N
T C
E N
T E
R
B
IS
H
O P
S T
S
U
IT
E
H O
N O
L U
L U
H A
W A
II
1/16" = 1'-0"A1
OVERALL HVAC & HVAC PIPING PLAN
PLAN NORTH
0 8' 16' 32'
GENERAL NOTES:
FOR MECHANICAL LEGENDS, NOTES AND
ABBREVIATIONS, SEE SHEET M-001.
1.
5.27.22
12"x12" EA
20"x18" OA
136A137A
137B
140B
140A
144B
141B
141A142
153A152A145A
149B
152B
148B
146 150
140141
151147
10"x10" SA
14"x10" OA
8"x8" RA
8"x6" SA
10"x10" SA
20"ø SA
12"x8" SA
12"x10" SA
8"x8" RA
12"x8" RA
(2)85-6"ø
SA-A
(2)85-6"ø
SA-A
(2)85-6"ø
SA-A
(2)85-6"ø
SA-A
(2)85-6"ø
SA-A
(2)90-6"ø
SA-A
(2)95-6"ø
SA-A
(2)95-6"ø
SA-A
(2)90-6"ø
SA-A
(2)85-6"ø
SA-A
VAV-153
VAV-152
VAV-149
VAV-148
VAV-145
200-8"x8"
RA-D
200-8"x8"
RA-D
"x
S A
VAV-144
VAV-141
VAV-140
35-6"ø
OA-A
VAV-136
VAV-137
VAV-180A
A
10"x10" SA
145B
10"x10" SA
6"x6" SA
"x
S A
6"x6" SA
10"x10" SA
6"x6" SA
125-6"x6"
RA-D
"x
R A
14"x12" RA
8"x8" RA
12"x10" EA
"x
E A
6"x6" SA
12"x8" RA
11' - 11" BOD EL
"ø
S A
"x
E A
8"x8" RA8 "x
R A
M A
T C
H L
IN
E
A
M -1
M A
T C
H L
IN
E
A
M -1
8"ø SA
75-6"ø
SA-A
20"x16" RA
20"x20" EA
18"x16" EA
6"x6" SA6"x6" SA 10"x10" SA
"x
S A
6"x6" SA
8"x8" RA
10"x8" OA
10"x8" EA "x
O A
"ø
S A
6"x6" SA
"x
O A
"x
E A
10"x10" SA12"x10" EA
8"ø SA
"x
O A
8"ø SA
"x
O A
(2)90-6"ø
SA-A
148A 149A
12"x8" RA
"ø
S A
420-10"ø
OA-A
360-8"ø
OA-A
440-10"ø
OA-A 420-10"ø
OA-A
80-8"x6"
TA-D
75-8"x6"
TA-D155-8"x6"
TA-D
75-8"x6"
TA-D
6"x6" SA
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
KEY PLAN
A B C
D
E
P L O
T D
A T
E
F
IL
E P
A T
H
C
R e v it P ro je c ts
\1 M
C e n tr a l_ jh c h o ri k i.
rv t
/2
/2
:3
:4
P
M
M-102
H V
A C
P L A
N
A R
E A
A
S C
H O
F
IE
L D
B A
R R
A C
K S
H
A W
A
II
H O
N O
L U
L U
D
IS
T R
IC
T
F T
S
H A
F T
E R
H
A W
A
II
H O
'O H
U I'I
A
J V
J C
H O
R
IK
I
J C
H O
R
IK
I
K M
O L
IN
A
/1
/2
D E
S
IG
N C
O M
P L E
T E
S U
B M
IT
T
A L
F Y
M
C A
P N
C
H
IL
D D
E V
E L O
P M
E N
T C
E N
T E
R
B
IS
H
O P
S T
S
U
IT
E
H O
N O
L U
L U
H A
W A
II
1/8" = 1'-0"A1
HVAC PLAN - AREA A
ROOM SCHEDULE - AREA A
NO. ROOM NAME
149 INFANT/PRE-TOD/TODDLER ACTIVITY ROOM
149A TOILET
149B STORAGE
150 BUGGY STORAGE
151 EXT. STORAGE
152 INFANT/PRE-TOD/TODDLER ACTIVITY ROOM
152A TOILET
152B STORAGE
153 INFANT/PRE-TOD/TODDLER ACTIVITY ROOM
153A TOILET
180 HALLWAY
ROOM SCHEDULE - AREA A
NO. ROOM NAME
142 TOILET
143 EXT. STORAGE
144 INFANT/PRE-TOD/TODDLER ACTIVITY ROOM
144A TOILET
144B STORAGE
145 INFANT/PRE-TOD/TODDLER ACTIVITY ROOM
145A TOILET
145B STORAGE
146 BUGGY STORAGE
147 EXT. STORAGE
148 INFANT/PRE-TOD/TODDLER ACTIVITY ROOM
148A TOILET
148B STORAGE
ROOM SCHEDULE - AREA A
NO. ROOM NAME
136 INFANT/PRE-TOD/TODDLER ACTIVITY ROOM
136A TOILET
137 INFANT/PRE-TOD/TODDLER ACTIVITY ROOM
137A TOILET
137B STORAGE
138 NURSING MOTHERS ROOM
139 EXT. STORAGE
140 INFANT/PRE-TOD/TODDLER ACTIVITY ROOM
140A TOILET
140B STORAGE
141 INFANT/PRE-TOD/TODDLER ACTIVITY ROOM
141A TOILET
141B STORAGE
GENERAL NOTES:
FOR MECHANICAL LEGENDS, NOTES AND ABBREVIATIONS,
SEE SHEET M-001.
T-STAT TO VAV CONNECTIONS ARE SHOWN ON M-107.
ALL DUCT SIZES TO VAV'S SHALL BE SAME AS INLET SIZE
SHOWN ON THE VAV SCHEDULE UNLESS NOTED
OTHERWISE.
ALL VAV TERMINAL UNITS MUST BE INSTALLED WITH A
MINIMUM LENGTH OF STRAIGHT DUCT AT THE INLET OF THE
VAV BOX EQUAL TO 6 TIMES THE INLET DIAMETER OR THE
MINIMUM MANUFACTURER RECOMMENDED LENGTH,
WHICHEVER IS LONGER, TO ENSURE ACCURATE AIR FLOW
MEASUREMENT AND CONTROL.
REFER TO ARCHITECTURAL FOR ACOUSTICAL WALL
PENETRATION DETAILS.
ALL DUCT RUNOUTS ARE AT 9'-4" TO CENTER OF DUCT
UNLESS NOTED OTHERWISE.
ALL VAV TERMINAL UNITS ARE SHOWN WITH ASSOCIATED
CLEARANCES. PROVIDE CLEARANCES IN ACCORDANCE
WITH MANUFACTURER RECOMMENDATIONS.
AIR TRANSFER FROM STORAGE TO MAIN ACTIVITY ROOM
AREAS PROVIDED VIA DOOR GAPS. REFER TO AIR FLOW
DIAGRAMS ON M-605 THRU M-610 FOR AIRFLOW QUANTITIES.
1.
2.
3.
4.
5.
6.
7.
8.
KEYED NOTES:
SUPPLY AIR DIFFUSER: 25 CFM, 6"x6", SA-B.1
EXHAUST AIR GRILLE: 150 CFM, 8"x8", EA-C. 2
8'4' 16'0
2 2
3 3
OUTSIDE AIR DIFFUSER: 300 CFM, 8" Ø, OA-A3
PLAN NORTH
RETURN AIR GRILLE: 310 CFM, 8"x8", RA-C4
RETURN AIR GRILLE: 270 CFM, 8"x8", RA-C5
TRANSFER AIR GRILLE: 150 CFM, 8"x6", TA-C6
PROVIDE MAINTENANCE ACCESS PANEL IN GYP CEILING
FOR VAV BOX.
5.27.22
"ø
S A
112A
133B
136B
112B
133A
156B
153B
132 129
132A
101155
D
"x
O A
"x
E A
"x
O A
12"x8" EA
M A
T C
H L
IN
E
A
M -1
M A
T C
H L
IN
E
A
M -1
M A
T C
H L
IN
E
A
M -1
M A
T C
H L
IN
E
A
M -1
MATCHLINE
A1/ M-105
MATCHLINE
A1/ M-105
"x
O A
12"x8" SA
45-6"ø
SA-C
140-6"ø
SA-C
195-6"ø
SA-C
(2)35-6"ø
OA-C
(2)85-6"ø
SA-A
25-6"ø
OA-A
"x
R A
155-6"ø
SA-A
(2)245-8"ø
SA-A
(2)75-6"ø
OA-A
VAV-125
"x
R A
235-8"ø
OA-A
235-8"ø
OA-A
185-6"ø
OA-A
170-6"ø
SA-A
170-6"ø
SA-A
185-6"x8"
RA-D
(2)245-10"x10"
RA-D
(2)290-10"x10"
RA-D
"x
S A
(2)140-6"ø
SA-A
(2)160-6"ø
SA-A
350-10"x10"
RA-D
200-8"x8"
RA-D
VAV-133 VAV-132
VAV-103
VAV-156
VAV-104
40-6"ø
OA-A
40-6"ø
OA-A
40-6"ø
OA-A135-6"ø
OA-A
420-10"ø
OA-A
345-8"ø
OA-A
20"x20" RA
26"ø SA
15' - 8" BOD EL
"x
O A
VAV-112
22"x22" OA
EF-129
16"x16" EA
230-8"ø
OA-A
12"x10" SA
9' - 10" BOD EL
FCU-127
B
A3
M-303
25-6"ø
OA-A
14"x8" SA
"x
R A
10"x10" SA
105 106
185-6"x8"
RA-D108
124A
E H3
M-303 H3
M-301
"x
S A
8"x6" SA
28"x30" EA28"x28" EA "x
E A
20"x20" EA
22"x22" EA
185-6"ø
OA-A
70-6"ø
SA-A75-6"ø
SA-A
6"x6" SA
12"x8" EA
20"x18" RA
12' - 5" BOD EL
20"x20" EA
14' - 4" BOD EL
20"x16" RA
10"x10" SA
14"x12" RA
20"x18" RA
22"x20" EA
"ø
S A
26"ø SA
6"x6" SA
26"x24" RA
"x
R A
"x
E A
25-6"x6"
OA-F
"x
O A
"x
E A
6"x6" SA
125-6"ø
SA-A
170-10"x10"
RA-D
156A
50-12"x10"
EA-E
110-8"x8"
EA-E
(2)155-8"x8"
EA-E
390-8"x8"
EA-E
24"x22" OA
10"x10" SA
140-10"x10"
RA-D
240-10"x10"
RA-D
12"x8" SA
12"x10" SA
12' - 7" BOD EL
75-6"x6"
RA-D
70-6"x6"
RA-D
30-6"ø
SA-C
75-8"x6"
TA-D
150-8"x6"
TA-D
150-6"x8"
TA-D
"ø
S A
22"ø SA22"ø SA
"x
O A
24"x22" EA
85-6"ø
OA-A
22"x20" OA
12' - 8" BOD EL
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
KEY PLAN
A B C
D
E
P L O
T D
A T
E
F
IL
E P
A T
H
C
R e v it P ro je c ts
\1 M
C e n tr a l_ jh c h o ri k i.
rv t
/2
/2
:3
:4
P
M
M-103
H V
A C
P L A
N
A R
E A
B
S C
H O
F
IE
L D
B A
R R
A C
K S
H
A W
A
II
H O
N O
L U
L U
D
IS
T R
IC
T
F T
S
H A
F T
E R
H
A W
A
II
H O
'O H
U I'I
A
J V
J C
H O
R
IK
I
J C
H O
R
IK
I
K M
O L
IN
A
/1
/2
D E
S
IG
N C
O M
P L E
T E
S U
B M
IT
T
A L
F Y
M
C A
P N
C
H
IL
D D
E V
E L O
P M
E N
T C
E N
T E
R
B
IS
H
O P
S T
S
U
IT
E
H O
N O
L U
L U
H A
W A
II
1/8" = 1'-0"A1
HVAC PLAN - AREA B
ROOM SCHEDULE - AREA B
NO. ROOM NAME
133 INFANT/PRE-TOD/TODDLER ACTIVITY ROOM
133A TOILET
133B STORAGE
134 TOILET
135 EXT. STORAGE
136B STORAGE
153B STORAGE
154 BUGGY STORAGE
155 EXT. STORAGE
156 INFANT/PRE-TOD/TODDLER ACTIVITY ROOM
156A TOILET
156B STORAGE
180 HALLWAY
181 HALLWAY 2
ROOM SCHEDULE - AREA B
NO. ROOM NAME
112A ACTIVE PLAY ROOM TOILET
112B ACTIVE PLAY ROOM STORAGE
124 PRESCHOOL/PRE-K/KINDERGARTEN ACTIVITY ROOM
124A TOILET
125 STAFF LOUNGE
126 STROLLER/CAR SEAT AREA
127 COMMUNICATIONS
128 CENTRAL STORAGE
129 ELECTRICAL ROOM
130 JANITOR CLOSET
131 STROLLER/CAR SEAT AREA
132 TRAINING ROOM
132A STORAGE
ROOM SCHEDULE - AREA B
NO. ROOM NAME
100 COVERED ENTRY
101 VESTIBULE
102 WAITING AREA
103 RECEPTION
104 OPEN OFFICE AREA
105 ASSISTANT DIRECTOR'S OFFICE
106 DIRECTOR'S OFFICE
107 ISOLATION AREA
108 ISO TOILET
109 ADMIN STORAGE
110 PUBLIC TOILET
111 PUBLIC TOILET
112 ACTIVE PLAY ROOM
GENERAL NOTES:
FOR MECHANICAL LEGENDS, NOTES AND ABBREVIATIONS,
SEE SHEET M-001.
T-STAT TO VAV CONNECTIONS AND HVAC PIPING ARE
SHOWN ON M-108.
ALL DUCT SIZES TO VAV'S SHALL BE SAME AS INLET SIZE
SHOWN ON THE VAV SCHEDULE UNLESS NOTED
OTHERWISE.
ALL VAV TERMINAL UNITS MUST BE INSTALLED WITH A
MINIMUM LENGTH OF STRAIGHT DUCT AT THE INLET OF THE
VAV BOX EQUAL TO 6 TIMES THE INLET DIAMETER OR THE
MINIMUM MANUFACTURER RECOMMENDED LENGTH,
WHICHEVER IS LONGER, TO ENSURE ACCURATE AIR FLOW
MEASUREMENT AND CONTROL.
REFER TO ARCHITECTURAL FOR ACOUSTICAL WALL
PENETRATION DETAILS.
ALL DUCT RUNOUTS ARE AT 9'-4" TO CENTER OF DUCT
UNLESS NOTED OTHERWISE.
ALL VAV TERMINAL UNITS ARE SHOWN WITH ASSOCIATED
CLEARANCES. PROVIDE CLEARANCES IN ACCORDANCE
WITH MANUFACTURER RECOMMENDATIONS.
AIR TRANSFER FROM STORAGE TO MAIN ACTIVITY ROOM
AREAS PROVIDED VIA DOOR GAPS. REFER TO AIR FLOW
DIAGRAMS ON M-605 THRU M-610 FOR AIRFLOW QUANTITIES.
1.
2.
3.
4.
5.
6.
7.
8.
KEYED NOTES:
16"x16" UP TO GOOSENECK ON ROOF. MOTORIZED
DAMPER IN VERTICAL INTERLOCKED WITH EF-129.
EXHAUST AIR GRILLE: 150 CFM, 8"x8", EA-C.
SUPPLY AIR DIFFUSER: 25 CFM, 6" Ø, SA-B.
8'4' 16'0
PLAN NORTH
4 TRANSFER AIR GRILLE: 150 CFM, 8"x6", TA-C.
6 SUPPLY AIR DIFFUSER: 25 CFM, 6" Ø, SA-A.
5 TRANSFER AIR GRILLE: 150 CFM, 8"x6", TA-D.
7 EXHAUST AIR GRILLE: 150 CFM, 8"x8", EA-D.
S
S
S
5.27.22
4"ø EA
121A
121B
124B
118B
M A
T C
H L
IN
E
A
M -1
M A
T C
H L
IN
E
A
M -1
VAV-124
VAV-118
VAV-180B
VAV-121
150-6"ø
SA-A
(2)155-6"ø
SA-A
(2)230-8"ø
OA-A
(2)230-8"ø
OA-A
45-6"ø
SA-A
110-8"ø
OA-C
230-8"ø
OA-A
155-6"ø
SA-A
"x
S A
"x
E A
10"x8" EA
170-10"x10"
RA-D
FCU-116
(2)165-8"x6"
RA-D
150-6"ø
SA-A
12"x10" SA
113A
M-401 A1
M-402 A1
M-403 A1
40"X60"
LOUVER,
TYP OF 2
16"x12" EA
F
"x
O A
118A
(2)170-10"x10"
RA-D
H3
M-302
A3
M-302
E14
M-104
"x
O A
"x
O A
"x
R A
115-12"x10"
RA-D
10"x10" RA
185-6"x8"
RA-D
26"x24" RA
28"x30" EA
45-6"ø
SA-A
"x
S A
"x
S A
12"x10" SA
10"x8" EA
26"x24" RA
30"x30" EA
1100-16"ø
OA-C
1100-12"x12"
EA-E
22"x12" OA
4"ø EA
4"ø EASF-114
600-12"ø
OA-C
12"x12" OA
6"x6" SA "x
S A
12"x10" SA
10"x10" SA
6"ø SA6"ø SA
6"ø SA
8"x8" SA
100-6"x6"
EA-D
6"x6" EA
8' - 8" BOD EL
26"ø SA
15' - 5" BOD EL
26"ø SA
14' - 6" BOD EL
10"x10" RA 6"x6" SA
170-8"x8"
EA-E
(2)185-8"x8"
EA-E
32"x28" OA 34"x28" OA
170-8"x6"
RA-D
80-8"x6"
RA-D
90-8"x6"
RA-D
26"ø SA
TOP OF PLATE
110' - 0"
34"x28" OA
22"x12" OA
26"ø SA
10"x8" RA
12"x22" OA
6"x6" SA
FROM AHU-1
FROM DOAS-1
TO DOAS-1
TO AHU-1
FROM AHU-236"x36" OA
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
KEY PLAN
A B C
D
E
P L O
T D
A T
E
F
IL
E P
A T
H
C
R e v it P ro je c ts
\1 M
C e n tr a l_ jh c h o ri k i.
rv t
/2
/2
:3
:5
P
M
M-104
H V
A C
P L A
N
A R
E A
C
S C
H O
F
IE
L D
B A
R R
A C
K S
H
A W
A
II
H O
N O
L U
L U
D
IS
T R
IC
T
F T
S
H A
F T
E R
H
A W
A
II
H O
'O H
U I'I
A
J V
J C
H O
R
IK
I
J C
H O
R
IK
I
K M
O L
IN
A
/1
/2
D E
S
IG
N C
O M
P L E
T E
S U
B M
IT
T
A L
F Y
M
C A
P N
C
H
IL
D D
E V
E L O
P M
E N
T C
E N
T E
R
B
IS
H
O P
S T
S
U
IT
E
H O
N O
L U
L U
H A
W A
II
1/8" = 1'-0"A1
HVAC PLAN - AREA C
ROOM SCHEDULE - AREA C
NO. ROOM NAME
122 TOILET
123 EXT. STORAGE
124B STORAGE
180 HALLWAY
ROOM SCHEDULE - AREA C
NO. ROOM NAME
118A TOILET
118B STORAGE
119 CENTRAL STORAGE 2
120 EXT. STORAGE
121 PRESCHOOL/PRE-K/KINDERGARTEN ACTIVITY ROOM
121A TOILET
121B STORAGE
ROOM SCHEDULE - AREA C
NO. ROOM NAME
113 KITCHEN
113A DRY FOOD STORAGE
114 LAUNDRY ROOM
115 ELECTRICAL ROOM 2
116 CCTV EQUIPMENT ROOM
117 MECHANICAL
118 OUTREACH/TRANSITIONAL CARE ACTIVITY ROOM
GENERAL NOTES:
FOR MECHANICAL LEGENDS, NOTES AND ABBREVIATIONS,
SEE SHEET M-001.
T-STAT TO VAV CONNECTIONS AND HVAC PIPING ARE
SHOWN ON M-109.
ALL DUCT SIZES TO VAV'S SHALL BE SAME AS INLET SIZE
SHOWN ON THE VAV SCHEDULE UNLESS NOTED
OTHERWISE.
ALL VAV TERMINAL UNITS MUST BE INSTALLED WITH A
MINIMUM LENGTH OF STRAIGHT DUCT AT THE INLET OF
THE VAV BOX EQUAL TO 6 TIMES THE INLET DIAMETER OR
THE MINIMUM MANUFACTURER RECOMMENDED LENGTH,
WHICHEVER IS LONGER, TO ENSURE ACCURATE AIR FLOW
MEASUREMENT AND CONTROL.
REFER TO ARCHITECTURAL FOR ACOUSTICAL WALL
PENETRATION DETAILS.
ALL DUCT RUNOUTS ARE AT 9'-4" TO CENTER OF DUCT
UNLESS NOTED OTHERWISE.
ALL VAV TERMINAL UNITS ARE SHOWN WITH ASSOCIATED
CLEARANCES. PROVIDE CLEARANCES IN ACCORDANCE
WITH MANUFACTURER RECOMMENDATIONS.
AIR TRANSFER FROM STORAGE TO MAIN ACTIVITY ROOM
AREAS PROVIDED VIA DOOR GAPS. REFER TO AIR FLOW
DIAGRAMS ON M-605 THRU M-610 FOR AIRFLOW
QUANTITIES.
1.
2.
3.
4.
5.
6.
7.
8.
KEYED NOTES:
SUPPLY AIR DIFFUSER: 30 CFM, 6"x6", SA-B.1
EXHAUST AIR GRILLE: 150 CFM, 8"x8", EA-C. 2
3 DRYER EXHAUST 4" Ø, TYPICAL OF 3. SEE ENLARGED
MECHANICAL ROOM PLANS FOR CONTINUATION.
NOT USED.4
8'4' 16'0
PLAN NORTHPLAN NORTH
OUTSIDE AIR DIFFUSER: 25 CFM, 8"x8", OA-B.5
TRANSFER AIR GRILLE: 150 CFM, 8"x6", TA-C. 6
SUPPLY AIR DIFFUSER: 25 CFM, 6" Ø, SA-A.7
1/4" = 1'-0"E14
DUCTWORK FROM MECH ROOM TO CORRIDOR
12"x12" UP TO GOOSENECK ON ROOF. MOTORIZED
DAMPER IN VERTICAL INTERLOCKED WITH SF-114.
WALL MOUNT DRYER BOOSTER NOTIFICATION PANEL IN
ACCORDANCE WITH MANUFACTURER REQUIREMENTS.
0 2' 4' 8'
PROVIDE SECONDARY LINT TRAP FOR EACH
DEDICATED DRYER EXHAUST LINE IN WALL BEHIND
EACH DRYER.
5.27.22
8"ø SA
157B 158B
157A
170A
170B
167B
158A 167A
D
"x
O A
"ø
S A
MATCHLINE
A1/ M-103
MATCHLINE
A1/ M-103
MATCHLINE
A1/ M-106
MATCHLINE
A1/ M-106
175-6"ø
SA-A
125-6"ø
SA-A
75-6"ø
SA-A
(2)230-8"ø
OA-A
(2)230-8"ø
OA-A
(2)125-6"ø
SA-A
12"x10" SA
12"x10" SA
"x
S A
12"x10" SA
9' - 7" BOD EL
12"x10" SA
VAV-157
VAV-158
VAV-167
12"x12" EA
190-10"x10"
RA-D
300-10"x10"
RA-D
VAV-170
190-10"x10"
RA-D
VAV-180C
8"x8" EA
"x
S A
"x
E A
"x
E A
"x
O A
"x
R A
B
A3
M-301
EC
190-10"x10"
RA-D
"ø
S A
DP
"x
E A
(2)235-8"ø
OA-A (2)240-8"ø
OA-A
(2)170-6"ø
SA-A
(2)175-6"ø
SA-A
(2)125-6"ø
SA-A
230-8"ø
OA-A
230-8"ø
OA-A
"x
E A
"x
E A
12"x12" EA
"x
S A
"x
S A
190-10"x10"
RA-D
140-10"x10"
RA-D
14"x12" RA
10"x10" RA
8"x8" OA
"x
R A
"x
R A
300-10"x10"
RA-D
"x
S A
8"x8" SA
8"x8" SA
8"x8" OA
9' - 8" BOD EL
8"x8" OA
9' - 8" BOD EL
8"x8" OA
14"x12" RA
10"x10" RA
140-10"x10"
RA-D
8"ø SA
18"x18" EA
14"x12" RA10"x10" RA
8"x8" OA
8"x8" SA
"x
S A
12"x8" EA
8"x8" EA
8"x8" OA
14"x12" RA 10"x10" RA
12"x10" SA
14"x12" RA
OFFSET DUCT
DOWN TO
CLOSET (TYP)
6"x6" SA
159A 166A
30-6"ø
SA-A
400-8"x8"
EA-E
190-10"x10"
RA-D
"x
E A
"x
E A
"x
R A
22"x20" OA
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
KEY PLAN
A B C
D
E
P L O
T D
A T
E
F
IL
E P
A T
H
C
R e v it P ro je c ts
\1 M
C e n tr a l_ jh c h o ri k i.
rv t
/2
/2
:3
:5
P
M
M-105
H V
A C
P L A
N
A R
E A
D
S C
H O
F
IE
L D
B A
R R
A C
K S
H
A W
A
II
H O
N O
L U
L U
D
IS
T R
IC
T
F T
S
H A
F T
E R
H
A W
A
II
H O
'O H
U I'I
A
J V
J C
H O
R
IK
I
J C
H O
R
IK
I
K M
O L
IN
A
/1
/2
D E
S
IG
N C
O M
P L E
T E
S U
B M
IT
T
A L
F Y
M
C A
P N
C
H
IL
D D
E V
E L O
P M
E N
T C
E N
T E
R
B
IS
H
O P
S T
S
U
IT
E
H O
N O
L U
L U
H A
W A
II
1/8" = 1'-0"A1
HVAC PLAN - AREA D
ROOM SCHEDULE - AREA D
NO. ROOM NAME
167A TOILET
167B STORAGE
168 CENTRAL STORAGE
169 EXT. STORAGE
170 PRESCHOOL/PRE-K/KINDERGARTEN ACTIVITY ROOM
170B STORAGE
181 HALLWAY 2
ROOM SCHEDULE - AREA D
NO. ROOM NAME
157 ACTIVE PLAY ROOM 2
157A ACTIVE PLAY ROOM 2 TOILET
157B ACTIVE PLAY ROOM 2 STORAGE
158 PRESCHOOL/PRE-K/KINDERGARTEN ACTIVITY ROOM
158A TOILET
158B STORAGE
167 PRESCHOOL/PRE-K/KINDERGARTEN ACTIVITY ROOM
GENERAL NOTES:
FOR MECHANICAL LEGENDS, NOTES AND ABBREVIATIONS,
SEE SHEET M-001.
T-STAT TO VAV CONNECTIONS ARE SHOWN ON M-110.
ALL DUCT SIZES TO VAV'S SHALL BE SAME AS INLET SIZE
SHOWN ON THE VAV SCHEDULE UNLESS NOTED
OTHERWISE.
ALL VAV TERMINAL UNITS MUST BE INSTALLED WITH A
MINIMUM LENGTH OF STRAIGHT DUCT AT THE INLET OF
THE VAV BOX EQUAL TO 6 TIMES THE INLET DIAMETER OR
THE MINIMUM MANUFACTURER RECOMMENDED LENGTH,
WHICHEVER IS LONGER, TO ENSURE ACCURATE AIR
FLOW MEASUREMENT AND CONTROL.
REFER TO ARCHITECTURAL FOR ACOUSTICAL WALL
PENETRATION DETAILS.
ALL DUCT RUNOUTS ARE AT 9'-4" TO CENTER OF DUCT
UNLESS NOTED OTHERWISE.
ALL VAV TERMINAL UNITS ARE SHOWN WITH ASSOCIATED
CLEARANCES. PROVIDE CLEARANCES IN ACCORDANCE
WITH MANUFACTURER RECOMMENDATIONS.
AIR TRANSFER FROM STORAGE TO MAIN ACTIVITY ROOM
AREAS PROVIDED VIA DOOR GAPS. REFER TO AIR FLOW
DIAGRAMS ON M-605 THRU M-610 FOR AIRFLOW
QUANTITIES.
1.
2.
3.
4.
5.
6.
7.
8.
KEYED NOTES:
SUPPLY AIR DIFFUSER: 30 CFM, 6" Ø, SA-B.1
EXHAUST AIR GRILLE: 195 CFM, 8"x8", EA-C. 2
DP
8'4' 16'0
PLAN NORTH
PROVIDE DUCT STATIC PRESSURE TAP. REFER TO
M-708 FOR CONTROLS.
SUPPLY AIR DIFFUSER: 25 CFM, 6" Ø, SA-A.4
PROVIDE MAINTENANCE ACCESS PANEL IN GYP CEILING
FOR VAV BOX.
5.27.22
"x
E A
"x
R A
162A
162B 159B
163A
166B
163B
D
175-6"ø
SA-A
125-6"ø
SA-A
MATCHLINE
A1/ M-105
MATCHLINE
A1/ M-105
12"x10" SA
12"x10" SA
10"x8" EA
"x
E A
8"x8" EA
12"x10" SA 12"x10" SA
185-6"ø
OA-A
(2)230-8"ø
OA-A
(2)230-8"ø
OA-A
(2)175-6"ø
SA-A
(2)125-6"ø
SA-A
190-10"x10"
RA-D
140-10"x10"
RA-D
190-8"x8"
RA-D
140-8"x8"
RA-D
230-8"ø
OA-A
230-8"ø
OA-A
175-6"ø
SA-A
125-6"ø
SA-A
"x
S A
VAV-162
VAV-163
VAV-159
VAV-166
14"x12" RA
B EC
"x
R A
8"ø SA
8"x8" OA 10"x10" RA
12"x8" RA
190-10"x10"
RA-D
140-10"x10"
RA-D
"ø
S A
"x
S A
"x
S A
8"x8" SA
"x
S A
"x
S A
8"x8" OA 12"x8" RA
8"x8" RA
"x
S A
"x
S A8"x8" SA
6"x6" SA
"x
E A
8"x8" OA
"x
R A
25-6"ø
SA-C
8"x8" SA 8"x8" SA
8"x8" SA
OFFSET DUCT
DOWN TO
CLOSET (TYP)
(2)185-8"x8"
EA-E
12"x10" OA 10"x8" OA
8"x8" OA
10"ø SA
160-6"x8"
RA-D
70-8"x6"
RA-D
90-8"x6"
RA-D
"x
O A
10"ø SA
"x
R A
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
KEY PLAN
A B C
D
E
P L O
T D
A T
E
F
IL
E P
A T
H
C
R e v it P ro je c ts
\1 M
C e n tr a l_ jh c h o ri k i.
rv t
/2
/2
:3
:0
P
M
M-106
H V
A C
P L A
N
A R
E A
E
S C
H O
F
IE
L D
B A
R R
A C
K S
H
A W
A
II
H O
N O
L U
L U
D
IS
T R
IC
T
F T
S
H A
F T
E R
H
A W
A
II
H O
'O H
U I'I
A
J V
J C
H O
R
IK
I
J C
H O
R
IK
I
K M
O L
IN
A
/1
/2
D E
S
IG
N C
O M
P L E
T E
S U
B M
IT
T
A L
F Y
M
C A
P N
C
H
IL
D D
E V
E L O
P M
E N
T C
E N
T E
R
B
IS
H
O P
S T
S
U
IT
E
H O
N O
L U
L U
H A
W A
II
1/8" = 1'-0"A1
HVAC PLAN - AREA E
ROOM SCHEDULE - AREA E
NO. ROOM NAME
163A TOILET
163B STORAGE
164 CENTRAL STORAGE
165 EXT. STORAGE
166 PRESCHOOL/PRE-K/KINDERGARTEN ACTIVITY ROOM
166A TOILET
166B STORAGE
181 HALLWAY 2
ROOM SCHEDULE - AREA E
NO. ROOM NAME
159 PRESCHOOL/PRE-K/KINDERGARTEN ACTIVITY ROOM
159A TOILET
159B STORAGE
160 TOILET
161 EXT. STORAGE
162 PRESCHOOL/PRE-K/KINDERGARTEN ACTIVITY ROOM
162A TOILET
162B STORAGE
163 PRESCHOOL/PRE-K/KINDERGARTEN ACTIVITY ROOM
GENERAL NOTES:
FOR MECHANICAL LEGENDS, NOTES AND ABBREVIATIONS,
SEE SHEET M-001.
T-STAT TO VAV CONNECTIONS ARE SHOWN ON M-111.
ALL DUCT SIZES TO VAV'S SHALL BE SAME AS INLET SIZE
SHOWN ON THE VAV SCHEDULE UNLESS NOTED
OTHERWISE.
ALL VAV TERMINAL UNITS MUST BE INSTALLED WITH A
MINIMUM LENGTH OF STRAIGHT DUCT AT THE INLET OF
THE VAV BOX EQUAL TO 6 TIMES THE INLET DIAMETER OR
THE MINIMUM MANUFACTURER RECOMMENDED LENGTH,
WHICHEVER IS LONGER, TO ENSURE ACCURATE AIR FLOW
MEASUREMENT AND CONTROL.
REFER TO ARCHITECTURAL FOR ACOUSTICAL WALL
PENETRATION DETAILS.
ALL DUCT RUNOUTS ARE AT 9'-4" TO CENTER OF DUCT
UNLESS NOTED OTHERWISE.
ALL VAV TERMINAL UNITS ARE SHOWN WITH ASSOCIATED
CLEARANCES. PROVIDE CLEARANCES IN ACCORDANCE
WITH MANUFACTURER RECOMMENDATIONS.
AIR TRANSFER FROM STORAGE TO MAIN ACTIVITY ROOM
AREAS PROVIDED VIA DOOR GAPS. REFER TO AIR FLOW
DIAGRAMS ON M-605 THRU M-610 FOR AIRFLOW
QUANTITIES.
1.
2.
3.
4.
5.
6.
7.
8.
KEYED NOTES:
SUPPLY AIR DIFFUSER: 30 CFM, 6" Ø, SA-B.1
EXHAUST AIR GRILLE: 150 CFM, 8"x8", EA-C. 2
8'4' 16'0
PLAN NORTH
8'4' 16'0
PLAN NORTH
5.27.22
T T T T T
T T T T T
T
145A
144B
141B
148B
145B
148A 149A
141A 140A144A
140B
137B
152B
149B
153A152A
137A 136A
136137
VAV-136
VAV-137
VAV-140
VAV-141
VAV-145
VAV-148 VAV-149
VAV-152
VAV-153
VAV-144
VAV-180A
A
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
KEY PLAN
A B C
D
E
P L O
T D
A T
E
F
IL
E P
A T
H
C
R e v it P ro je c ts
\1 M
C e n tr a l_ jh c h o ri k i.
rv t
/2
/2
:3
:0
P
M
M-107
H V
A C
P
IP
IN
G
P L A
N
A R
E A
A
S C
H O
F
IE
L D
B A
R R
A C
K S
H
A W
A
II
H O
N O
L U
L U
D
IS
T R
IC
T
F T
S
H A
F T
E R
H
A W
A
II
H O
'O H
U I'I
A
J V
J C
H O
R
IK
I
J C
H O
R
IK
I
K M
O L
IN
A
/1
/2
D E
S
IG
N C
O M
P L E
T E
S U
B M
IT
T
A L
F Y
M
C A
P N
C
H
IL
D D
E V
E L O
P M
E N
T C
E N
T E
R
B
IS
H
O P
S T
S
U
IT
E
H O
N O
L U
L U
H A
W A
II
1/8" = 1'-0"A1
HVAC PIPING PLAN - AREA A
GENERAL NOTES:
FOR MECHANICAL LEGENDS, NOTES AND
ABBREVIATIONS, SEE SHEET M-001.
DUCTWORK IS SHOWN ON M-102.
1.
2.
KEYED NOTES:
PROVIDE A TAMPER PROOF THERMOSTAT MOUNTED AT
44" - 48" ABOVE FINISHED FLOOR AND A SECOND
TEMPERATURE SENSOR AT 12" ABOVE FINISHED FLOOR
AS SHOWN IN DETAIL A10/M-507. THE TEMPERATURE
SENSOR SHALL BE INSTALLED VIRTUALLY FLUSH WITH
THE WALL (NO MORE THAN 1/2" PROJECTION) AND
SHALL NOT INCLUDE ANY THERMOSTAT CONTROL
CAPABILITIES.
ROOM SCHEDULE - AREA A
NO. ROOM NAME
149 INFANT/PRE-TOD/TODDLER ACTIVITY ROOM
149A TOILET
149B STORAGE
150 BUGGY STORAGE
151 EXT. STORAGE
152 INFANT/PRE-TOD/TODDLER ACTIVITY ROOM
152A TOILET
152B STORAGE
153 INFANT/PRE-TOD/TODDLER ACTIVITY ROOM
153A TOILET
180 HALLWAY
ROOM SCHEDULE - AREA A
NO. ROOM NAME
142 TOILET
143 EXT. STORAGE
144 INFANT/PRE-TOD/TODDLER ACTIVITY ROOM
144A TOILET
144B STORAGE
145 INFANT/PRE-TOD/TODDLER ACTIVITY ROOM
145A TOILET
145B STORAGE
146 BUGGY STORAGE
147 EXT. STORAGE
148 INFANT/PRE-TOD/TODDLER ACTIVITY ROOM
148A TOILET
148B STORAGE
ROOM SCHEDULE - AREA A
NO. ROOM NAME
136 INFANT/PRE-TOD/TODDLER ACTIVITY ROOM
136A TOILET
137 INFANT/PRE-TOD/TODDLER ACTIVITY ROOM
137A TOILET
137B STORAGE
138 NURSING MOTHERS ROOM
139 EXT. STORAGE
140 INFANT/PRE-TOD/TODDLER ACTIVITY ROOM
140A TOILET
140B STORAGE
141 INFANT/PRE-TOD/TODDLER ACTIVITY ROOM
141A TOILET
141B STORAGE
1 1 1 1 1
1 1 1 1 1
8'4' 16'0
PLAN NORTH
5.27.22
D
M A
T C
H L
IN
E
A
M -1
M A
T C
H L
IN
E
A
M -1
M A
T C
H L
IN
E
A
M -1
M A
T C
H L
IN
E
A
M -1
MATCHLINE
A1/ M-110
MATCHLINE
A1/ M-110
T
T
T
T
T
T
TT
T
FCU-127
VAV-132VAV-133
VAV-156
VAV-112
VAV-125
VAV-103 VAV-104
EF-129
136B
133B
133A
156B
153B
112B
112A
124A
132A
T
3/8" RS
1/4" RL
B
ESS
3/4" COND
A3
M-303
EC
H3
M-303 H3
M-301
CO2
T
T
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
KEY PLAN
A B C
D
E
P L O
T D
A T
E
F
IL
E P
A T
H
C
R e v it P ro je c ts
\1 M
C e n tr a l_ jh c h o ri k i.
rv t
/2
/2
:3
:0
P
M
M-108
H V
A C
P
IP
IN
G
P L A
N
A R
E A
B
S C
H O
F
IE
L D
B A
R R
A C
K S
H
A W
A
II
H O
N O
L U
L U
D
IS
T R
IC
T
F T
S
H A
F T
E R
H
A W
A
II
H O
'O H
U I'I
A
J V
J C
H O
R
IK
I
J C
H O
R
IK
I
K M
O L
IN
A
/1
/2
D E
S
IG
N C
O M
P L E
T E
S U
B M
IT
T
A L
F Y
M
C A
P N
C
H
IL
D D
E V
E L O
P M
E N
T C
E N
T E
R
B
IS
H
O P
S T
S
U
IT
E
H O
N O
L U
L U
H A
W A
II
1/8" = 1'-0"A1
HVAC PIPING PLAN - AREA B
GENERAL NOTES:
FOR MECHANICAL LEGENDS, NOTES AND
ABBREVIATIONS, SEE SHEET M-001.
DUCTWORK IS SHOWN ON M-103.
1.
2.
KEYED NOTES:
PROVIDE A TAMPER PROOF THERMOSTAT MOUNTED AT
44" - 48" ABOVE FINISHED FLOOR AND A SECOND
TEMPERATURE SENSOR AT 12" ABOVE FINISHED FLOOR
AS SHOWN IN DETAIL A10/M-507. THE TEMPERATURE
SENSOR SHALL BE INSTALLED VIRTUALLY FLUSH WITH
THE WALL (NO MORE THAN 1/2" PROJECTION) AND
SHALL NOT INCLUDE ANY THERMOSTAT CONTROL
CAPABILITIES.
PROVIDE HVAC SYSTEM EMERGENCY SHUTDOWN
BUTTON WITH NON-LOCKING PROTECTIVE COVER.
PROVIDE HVAC UNOCCUPIED OVERRIDE SWITCH.
PIPE CONDENSATE DRAIN TO, AND TURN DOWN INTO,
JANITOR SINK.
FINAL REFRIGERANT AND CONDENSATE LINES SHALL
BE SIZED AND INSTALLED PER MANUFACTURER'S
RECOMMENDATIONS.
INSTALL PRESSURE SENSOR ON EXTERIOR OF
BUILDING TO BE USED FOR DETERMINING BUILDING
DIFFERENTIAL PRESSURE.
INSTALL PRESSURE SENSOR IN CEILING TO BE USED
FOR DETERMINING BUILDING DIFFERENTIAL PRESSURE.
ROOM SCHEDULE - AREA B
NO. ROOM NAME
133 INFANT/PRE-TOD/TODDLER ACTIVITY ROOM
133A TOILET
133B STORAGE
134 TOILET
135 EXT. STORAGE
136B STORAGE
153B STORAGE
154 BUGGY STORAGE
155 EXT. STORAGE
156 INFANT/PRE-TOD/TODDLER ACTIVITY ROOM
156A TOILET
156B STORAGE
180 HALLWAY
181 HALLWAY 2
ROOM SCHEDULE - AREA B
NO. ROOM NAME
112A ACTIVE PLAY ROOM TOILET
112B ACTIVE PLAY ROOM STORAGE
124 PRESCHOOL/PRE-K/KINDERGARTEN ACTIVITY ROOM
124A TOILET
125 STAFF LOUNGE
126 STROLLER/CAR SEAT AREA
127 COMMUNICATIONS
128 CENTRAL STORAGE
129 ELECTRICAL ROOM
130 JANITOR CLOSET
131 STROLLER/CAR SEAT AREA
132 TRAINING ROOM
132A STORAGE
ROOM SCHEDULE - AREA B
NO. ROOM NAME
100 COVERED ENTRY
101 VESTIBULE
102 WAITING AREA
103 RECEPTION
104 OPEN OFFICE AREA
105 ASSISTANT DIRECTOR'S OFFICE
106 DIRECTOR'S OFFICE
107 ISOLATION AREA
108 ISO TOILET
109 ADMIN STORAGE
110 PUBLIC TOILET
111 PUBLIC TOILET
112 ACTIVE PLAY ROOM
2 3
1 1
8'4' 16'0
PLAN NORTH
5.27.22
M A
T C
H L
IN
E
A
M -1
M A
T C
H L
IN
E
A
M -1
T T
T
T
T
AHU-1
CH-1
FCU-116
VAV-124
VAV-121
VAV-118
VAV-180B
AHU-2
BF-1
BF-2
BF-3
EF-117
SF-113A
CU-127CU-REF CU-116
T
3/8" RS
1/4" RL
3/8" RS
1/4" RL
4" CHWS
4" CHWR
3/8" RS
1/4" RL
AC-113
F
H3
M-302
A3
M-302
C14
M-403 E14
M-104
BT-1
2" HWR
2" HWS
CV-1
DOAS-1
CV-2
CV-4
CV-5
CV-3
SF-114
DDC PANEL
43/4" COND2
INSULATED REFRIGERANT LINES
THRU 6" Ø BURIED CONDUIT 5
D14
M-109
CV-6
4" CHWS
4" CHWR
(2 EACH) 2-1/2" CHWS/CHWR
STUBOUTS WITH FIRE HOSE
QUICK CONNECT COUPLINGS
BT-2
AS-2
ET-2
AS-1
ET-1
HRP-1
HRP-2
CHP-2
CHP-1
CHEM-1
CHEM-2
3/4" COND
3/4" DCW POC
4" CHWS
2" HWS
4" CHWR
2" HWR
2 1/2" CHWS
1 1/2" CHWS
1 1/2" CHWR
2 1/2" CHWR
2" HWR 4" CHWR
3/4" DRAINS
FROM TANKS
1" CHWR
1" CHWS
3" CHWR
2" CHWR
3/4" COND
TO SINK
PROVIDE AIRGAP IN WALL
BEFORE SANITARY CONNECTION
PROVIDE WALL ACCESS PANEL
AT AIR GAP
GROUND FLOOR
100' - 0"
TOP OF PLATE
110' - 0"
3' - 0"
CH-1
CU-116
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
KEY PLAN
A B C
D
E
P L O
T D
A T
E
F
IL
E P
A T
H
C
R e v it P ro je c ts
\1 M
C e n tr a l_ jh c h o ri k i.
rv t
/2
/2
:3
:1
P
M
M-109
H V
A C
P
IP
IN
G
P L A
N
A R
E A
C
S C
H O
F
IE
L D
B A
R R
A C
K S
H
A W
A
II
H O
N O
L U
L U
D
IS
T R
IC
T
F T
S
H A
F T
E R
H
A W
A
II
H O
'O H
U I'I
A
J V
J C
H O
R
IK
I
J C
H O
R
IK
I
K M
O L
IN
A
/1
/2
D E
S
IG
N C
O M
P L E
T E
S U
B M
IT
T
A L
F Y
M
C A
P N
C
H
IL
D D
E V
E L O
P M
E N
T C
E N
T E
R
B
IS
H
O P
S T
S
U
IT
E
H O
N O
L U
L U
H A
W A
II
1/8" = 1'-0"A1
HVAC PIPING PLAN - AREA C
GENERAL NOTES:
FOR MECHANICAL LEGENDS, NOTES AND
ABBREVIATIONS, SEE SHEET M-001.
DUCTWORK IS SHOWN ON M-104.
1.
2.
KEYED NOTES:
PROVIDE A TAMPER PROOF THERMOSTAT MOUNTED AT
44" - 48" ABOVE FINISHED FLOOR AND A SECOND
TEMPERATURE SENSOR AT 12" ABOVE FINISHED FLOOR
AS SHOWN IN DETAIL A10/M-507. THE TEMPERATURE
SENSOR SHALL BE INSTALLED VIRTUALLY FLUSH WITH
THE WALL (NO MORE THAN 1/2" PROJECTION) AND
SHALL NOT INCLUDE ANY THERMOSTAT CONTROL
CAPABILITIES.
PIPE CONDENSATE DRAIN TO, AND TURN DOWN INTO,
FLOOR DRAIN/SINK.
NOT USED.
FINAL REFRIGERANT AND CONDENSATE LINES SHALL
BE SIZED AND INSTALLED PER MANUFACTURER'S
RECOMMENDATIONS.
ENDS OF 6" Ø BURIED CONDUIT TO STUB UP IN
MECHANICAL ROOM AND MECHANICAL YARD. BOTH
ENDS SHALL BE SEALED TO PREVENT WATER
INFILTRATION INTO PIPE.
PROVIDE PUMPS WITH VFD CONTROLS MOUNTED
DIRECTLY ON PUMP HOUSING. MAINTAIN 36" MINIMUM
CLEARANCE TO VFDS.
TURN DRAIN LINES INTO CONE TOP OVER FLOOR DRAIN.
ROOM SCHEDULE - AREA C
NO. ROOM NAME
122 TOILET
123 EXT. STORAGE
124B STORAGE
180 HALLWAY
ROOM SCHEDULE - AREA C
NO. ROOM NAME
118A TOILET
118B STORAGE
119 CENTRAL STORAGE 2
120 EXT. STORAGE
121 PRESCHOOL/PRE-K/KINDERGARTEN ACTIVITY ROOM
121A TOILET
121B STORAGE
ROOM SCHEDULE - AREA C
NO. ROOM NAME
113 KITCHEN
113A DRY FOOD STORAGE
114 LAUNDRY ROOM
115 ELECTRICAL ROOM 2
116 CCTV EQUIPMENT ROOM
117 MECHANICAL
118 OUTREACH/TRANSITIONAL CARE ACTIVITY ROOM
8'4' 16'0
1 1
PLAN NORTH
1/4" = 1'-0"D14
HVAC PIPING FROM MECH YARD TO MECH ROOM
0 2' 4' 8'
5.27.22
D
MATCHLINE
A1/ M-108
MATCHLINE
A1/ M-108
MATCHLINE
A1/ M-111
MATCHLINE
A1/ M-111
T
T
T
T T
TT
B
170A
169167B170B168181157A158B157B
167A
166A
159A
158A
166159
VAV-158
VAV-157
VAV-170
VAV-167
A3
M-301
EC
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
KEY PLAN
A B C
D
E
P L O
T D
A T
E
F
IL
E P
A T
H
C
R e v it P ro je c ts
\1 M
C e n tr a l_ jh c h o ri k i.
rv t
/2
/2
:3
:1
P
M
M-110
H V
A C
P
IP
IN
G
P L A
N
A R
E A
D
S C
H O
F
IE
L D
B A
R R
A C
K S
H
A W
A
II
H O
N O
L U
L U
D
IS
T R
IC
T
F T
S
H A
F T
E R
H
A W
A
II
H O
'O H
U I'I
A
J V
J C
H O
R
IK
I
J C
H O
R
IK
I
K M
O L
IN
A
/1
/2
D E
S
IG
N C
O M
P L E
T E
S U
B M
IT
T
A L
F Y
M
C A
P N
C
H
IL
D D
E V
E L O
P M
E N
T C
E N
T E
R
B
IS
H
O P
S T
S
U
IT
E
H O
N O
L U
L U
H A
W A
II
1/8" = 1'-0"A1
HVAC PIPING PLAN - AREA D
GENERAL NOTES:
FOR MECHANICAL LEGENDS, NOTES AND
ABBREVIATIONS, SEE SHEET M-001.
DUCTWORK IS SHOWN ON M-105.
1.
2.
KEYED NOTES:
PROVIDE A TAMPER PROOF THERMOSTAT MOUNTED AT
44" - 48" ABOVE FINISHED FLOOR AND A SECOND
TEMPERATURE SENSOR AT 12" ABOVE FINISHED FLOOR
AS SHOWN IN DETAIL A10/M-507. THE TEMPERATURE
SENSOR SHALL BE INSTALLED VIRTUALLY FLUSH WITH
THE WALL (NO MORE THAN 1/2" PROJECTION) AND
SHALL NOT INCLUDE ANY THERMOSTAT CONTROL
CAPABILITIES.
ROOM SCHEDULE - AREA D
NO. ROOM NAME
167A TOILET
167B STORAGE
168 CENTRAL STORAGE
169 EXT. STORAGE
170 PRESCHOOL/PRE-K/KINDERGARTEN ACTIVITY ROOM
170B STORAGE
181 HALLWAY 2
ROOM SCHEDULE - AREA D
NO. ROOM NAME
157 ACTIVE PLAY ROOM 2
157A ACTIVE PLAY ROOM 2 TOILET
157B ACTIVE PLAY ROOM 2 STORAGE
158 PRESCHOOL/PRE-K/KINDERGARTEN ACTIVITY ROOM
158A TOILET
158B STORAGE
167 PRESCHOOL/PRE-K/KINDERGARTEN ACTIVITY ROOM
1 1
8'4' 16'0
PLAN NORTH
5.27.22
MATCHLINE
A1/ M-110
MATCHLINE
A1/ M-110
T T
B
VAV-162
VAV-163
VAV-159
VAV-166
162 163
163A
165163B166B164160159B162B161
162A
166159
EC
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D…