PN70551_CDC_SB_DWGS_AM-0002.pdf

PDF 9 MB Posted

Attached to
FY22 Military Construction Army (MCA) 070551 Child Development Center, Schofield Barracks, Oahu, Hawaii
Solicitation number
W9128A22R0020
Issued by

About this file

This federal contract opportunity announcement seeks proposals for the FY23 Military Construction Army project to construct a 37,300 square foot Child Development Center at Schofield Barracks, Hawaii. Key details include that the project scope encompasses the Child Development Center building, 38,311 square feet of playground area, 146 parking spaces, site development, utilities and connections, and demolition of five existing buildings. Proposals are due by Thursday, June 23, 2022 and will be evaluated on experience, past performance, technical approach, and price using LPTA procedures. Award is expected within 1,237 calendar days of notice to proceed, with a project magnitude between $25-50 million. Subcontracting goals apply for small, small disadvantaged, women-owned, HUBZone, veteran-owned, and service disabled veteran-owned small businesses.

View the file

Other files

File Type Posted
22r20-CDC SB-Am-0008.pdf PDF
22r20-CDC SB-Am-0007.pdf PDF
PN70551_CDC_SB_DWGS_Am-0007.pdf PDF
22r20-CDC SB-Am-0006.pdf PDF
22r20-CDC SB-Am-0005.pdf PDF
PN70551_CDC_SB_DWGS_Am-0005.pdf PDF
PN70551_CDC_SB_DWGS_Am-0004.pdf PDF
22r20-CDC SB-Am-0004.pdf PDF
PN70551_CDC_SB_DWGS_AM-0003.pdf PDF
22r20-CDC SB-Am-0003.pdf PDF
PN70551_DESIGN COMPLETE_DWG-am-0002-Part4.pdf PDF
22r20-CDC SB-Am-0002.pdf PDF
PN70551_DESIGN COMPLETE_DWG-am-0002-Part1.pdf PDF
PN70551_DESIGN COMPLETE_DWG-am-0002-Part3.pdf PDF
PN70551_DESIGN COMPLETE_SPEC-am-0002.pdf PDF
PN70551_DESIGN COMPLETE_DWG-am-0002-Part5.pdf PDF
PN70551_DESIGN COMPLETE_DWG-am-0002-Part2.pdf PDF
PN70551_DESIGN COMPLETE_DWG-am-0002-Part6.pdf PDF
22r20-CDC SB-Am-0001.pdf PDF
22r20 - RFP.pdf PDF
PN70551_100_DWG_Part1.pdf PDF
PN70551_100_DWG_Part6.pdf PDF
PN70551_100_DWG_Part11.pdf PDF
PN70551_100_DWG_Part9.pdf PDF
PN70551_100_DWG_Part2.pdf PDF
22r20-Map-SB.pdf PDF
PN70551_100_DWG_Part3.pdf PDF
PN70551_100_DWG_Part7.pdf PDF
PN70551_100_DWG_Part10.pdf PDF
PN70551_100_DWG_Part5.pdf PDF
PN70551_100_SPEC.pdf PDF
PN70551_100_DWG_Part8.pdf PDF
PN70551_100_DWG_Part4.pdf PDF
Show all 33

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ro of li n e double yel low linerefblue ref wh ite lin e ref blueref wh ite li ne / r e f ref wh ite lin e wh ite li ne / r e f wh ite li ne / r e f wh ite li ne / r e f ref

STAFF

ONLY

STAFF

ONLY

STAFF

ONLY

STAFF

ONLY

STAFF

ONLY

STAFF

ONLY

STAFF

ONLY

S

TA

FF

O

N

LY

S

TA

FF

O

N

LY

S

TAF

F

O

NL

Y S

TAF

F

O

NL

Y S

TAF

F

O

NL

Y S

TAF

F

O

NL

Y S

TAF

F

O

NL

Y S

TAF

F

O

NL

Y S

TAF

F

O

NL

Y S

TAF

F

O

NL

Y S

TAF

F

O

NL

Y S

TAF

F

O

NL

Y S

TAF

F

O

NL

Y S

TAF

F

O

NL

Y S

TAF

F

O

NL

Y S

TAF

F

O

NL

Y S

TAF

F

O

NL

Y S

TAF

F

O

NL

Y

STAFF

ONLY

STAFF

ONLY

STAFF

ONLY

STAFF

ONLY

STAFF

ONLY

S

TA

FF

O

N

LY

S

TA

FF

O

N

LY

S

TA

FF

O

N

LY

S

TA

FF

O

N

LY

S

TA

FF

O

N

LY

S

TA

FF

O

N

LY

IKELEA ST.

K A

IO

N A A

V E

04/30/2024

A

ARCHITECT

PROFESSIONAL

LICENSED

W A

H

A.

U.

I

I S.

M

A J

No. 8352

L.

ES TS

N O

E

License Expiration Date

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

US Army Corps of Engineers ®

CONTRACT NO.:

ISSUE DATE:

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

P L O

T D

A T

E

F

IL

E P

A T

H

I:

\N

E W

G \2

-0

F

Y C

D C

S c h o fi e ld

B a rr a c k s -J im \0

-F

IN

A

L \P

N C

D C

S

B M

M I_

R V

T A

.r v t

/1

/2

:0

:4

P

M

G-001

C O

V E

R

S C

H O

F

IE

L D

B A

R R

A C

K S

H

A W

A

II

H O

N O

L U

L U

D

IS

T R

IC

T

F T

S

H A

F T

E R

H

A W

A

II

B U

R N

S

M C

D O

N N

E L L G

J S

T O

N E

E

IG

N A

C

IO

R

IN

O U

Y E

/1

/2

D E

S

IG

N C

O M

P L E

T E

S U

B M

IT

T

A L

F Y

M

C A

P N

C

H

IL

D D

E V

E L O

P M

E N

T C

E N

T E

R

HONOLULU DISTRICT

05/16/2022

SCHOFIELD BARRACKS, HAWAII

FY21 MCA PN70551 CHILD DEVELOPMENT CENTER

B

IS

H

O P

S T

R E

E T

S U

IT

E

H O

N O

L U

L U

H

I A

PROJECT

LOCATION

LOCATION MAP

VICINITY MAP

OWNER:

DEPARTMENT OF THE ARMY

CONTRACT DIVISION (CEPOH-CT-C)

US ARMY ENGINEER DISTRICT, HONOLULU, BLDG. 230

FORT SHAFTER, HI 96858-5440

CIVIL & ARCHITECTURAL:

G70 (GROUP 70)

111 S. KING STREET, SUITE 170

HONOLULU, HAWAII 9681

STRUCTURAL:

KAI HAWAII

50 SOUTH BERETANIA SUITE C-119C,

HONOLULU, HI 96813

FIRE LIFE SAFETY, MECHANICAL, ELECTRICAL &

TELECOMMUNICATIONS:

BURNS & MCDONNELL

735 BISHOP STREET SUITE 2000

HONOLULU, HI 96813

KITCHEN:

MIZO & ASSOCIATES

408 N KUAKINI ST # 1,

HONOLULU, HI 96817

LANDSCAPE:

BROWNIE & LEE

201 MERCHANT STREET # 1930,

HONOLULU, HAWAII 96813

PLAN

NORTH

P

LAN

N O R

TH

PROJECT TEAM

0 100' 200' 400'

0 500' 1000' 2000'

A2

A M-

RE

MO

VE

B

ID

O

PT

IO

N

3 F

RO

M

CO

NT

RA

CT

/27 /20

X

X

X

X

X

LYMAN ROAD

IKELE

A ST

IK

EL

EA

S

T

KUAIKUA STREET

KAIO

NA

AVENUE

ULRICH WAY

KOLEKOLE AVENUE

CADET SHERIDAN

ROAD

ULRICH WAY

LIMIT OF WORK

ENTRANCE TO CDC

SCHOFIELD BARRACKS

SEE KEY MAP FOR

CONTINUATION TO

LYMAN GATE

HAUL ROUTE

PROPOSED CDC

BUILDING FOOTPRINT

APPROX. LEASE

BOUNDARY LINE

APPROX. LEASE

BOUNDARY LINE

CONSTRUCTION ENTRANCE

D

ES

IG

N

C O

M

PL

ET

E

SU

BM

IT

TA

L

SC

H

O

FI

EL

D

B

AR

R

AC

KS

, H

AW

AI

I

FY

M

C A

PN

C H

IL

D

D

EV

EL

O

PM

EN

T C

EN

TE

R

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

A

B

C

D

E

F

G

H

J

K

L

M

N

P

SU

BM

IT

TE

D B

Y:

C H

EC

KE

D B

Y:

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

IS

SU

E D

AT

E:

SI

ZE

M

AR

K

D

ES

C R

IP

TI

O N

D

AT

E

SHEET ID

US Army Corps of Engineers

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

P:

\2

9\

-0

FY

C

D C

S C

H O

FI

EL

D B

AR

R

AC

KS

\C

IV

IL

\D

W G

\P N

1_ C

D C

_S B_

C -1

.D

W G

6/

/2

:4 6:

A

M

PL

O T

D

AT

E:

FI

LE

P

AT

H

FT

. S

H

AF

TE

R

, H

AW

AI

I

H O

N O

LU

LU

D

IS

TR

IC

T

H O

'O H

U I'I

A

- J

V

BI

SH

O P

ST

, S

U

IT

E

H

O N

O

LU

LU

H

AW

AI

I 9

ST

AF

F

ST

AF

F

R . C

H

AR

/1

6/

AN

SI

D

HAUL ROUTE NOTES:

1. HAUL ROUTE SHOWN IS PROJECTED AND MAY CHANGE DURING

THE PROJECT CONSTRUCTION DURATION DUE TO OTHER

CONSTRUCTION PROJECTS AND BASE ACTIVITIES.

2. COORDINATE WITH CONTRACTING OFFICER OR DESIGNATED

REPRESENTATIVE FOR HAUL ROUTE AT THE START OF

CONSTRUCTION AND FOR THE CONSTRUCTION DURATION.

3. CONTRACTOR SHALL CONSIDER TRAFFIC CONDITIONS ON LYMAN

ROAD AND KOLEKOLE AVENUE WHEN SCHEDULING DELIVERIES

AND SHALL MAKE HEAVY VEHICLE OR LARGE DELIVERIES DURING

OFF-PEAK HOURS.

COSA NOTES:

1. COSA SHALL BE INSTALLED WITHIN THE PROJECT LIMITS.

CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING

APPROPRIATE LOCATION AND OBTAINING APPROVAL FROM DPW.

2. REMOVE DEBRIS AND GRADE TO DRAIN WITH SLOPE NECESSARY

FOR COSA OPERATIONS.

H

AU

L R

O U

TE

A

N D

C O

SA

KUNIA

ROAD

WILIKINA DR.

AVE.

FOOTE AVE.

LYMAN RD.

KOLEKOLE

IKELEA

ST.

FLAG

LER

R O

AD

H U

M

PH

R

EYS

R O

AD

KAIO

N

A AVE.

ULRICH WAY

LYMAN GATE

FOOTE GATE

SCHOFIELD BARRACKS

KEY MAP

NOT TO SCALE

HAUL ROUTE

NOTE:

1. TRAFFIC ROUTE SHALL BE INTO THE

PROJECT SITE FROM HUMPHREYS ROAD

AND EXIT THROUGH FLAGLER ROAD.

HAUL ROUTE AND COSA

SCALE: 1" = 60'A1

0 60' 120'

SCALE: 1" = 60'

C-101

PLAN NORTH

PLAN NORTH

A2

A2

AM

-0

- R

EM

O

VE

B

ID

O

PT

IO

N

F R

O M

C O

N

TR

AC

T

6/

/2

U, .

No. 15480-C

ENGINEER

PROFESSIONAL

LICENSED

S A.

A

HAW II

HM.

AN

Y RA

R

K. C

EXPIRATION DATE OF THE LICENSE 4/30/2024

THIS WORK WAS PREPARED BY ME

OR UNDER MY SUPERVISION

CD101CD102

CD103CD104

D

ES

IG

N

C O

M

PL

ET

E

SU

BM

IT

TA

L

SC

H

O

FI

EL

D

B

AR

R

AC

KS

, H

AW

AI

I

FY

M

C A

PN

C H

IL

D

D

EV

EL

O

PM

EN

T C

EN

TE

R

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

A

B

C

D

E

F

G

H

J

K

L

M

N

P

SU

BM

IT

TE

D B

Y:

C H

EC

KE

D B

Y:

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

IS

SU

E D

AT

E:

SI

ZE

M

AR

K

D

ES

C R

IP

TI

O N

D

AT

E

SHEET ID

US Army Corps of Engineers

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

P:

\2

9\

-0

FY

C

D C

S C

H O

FI

EL

D B

AR

R

AC

KS

\C

IV

IL

\D

W G

\P N

1_ C

D C

_S B_

C D

3.

D W

G 6/

/2

:5

2:

A M

PL

O

T D

AT

E:

FI

LE

P

AT

H

FT

. S

H

AF

TE

R

, H

AW

AI

I

H O

N O

LU

LU

D

IS

TR

IC

T

H O

'O H

U I'I

A

- J

V

BI

SH

O P

ST

, S

U

IT

E

H

O N

O

LU

LU

H

AW

AI

I 9

ST

AF

F

ST

AF

F

R . C

H

AR

/1

6/

AN

SI

D

MATCH LINE SEE SHEET CD102

M

AT

C H

L

IN

E

SE

E

SH

EE

T

C D

D

EM

O

LI

TI

O

N P

LA

N

APPROX. LEASE

BOUNDARY LINE

KUAIKUA

STREET

CITY & COUNTY OF HONOLULU EXCEPTIONAL

TREE. PROVIDE TREE PROTECTION TO ENSURE

NO DAMAGE OCCURS DURING CONSTRUCTION.

SEE TREE PROTECTION DETAILS AND NOTES ON

SHEETS L-502 AND L-503.

CD103

TREE REMOVAL NOTES:

PER USAG-HI TREE CUTTING MORATORIUM DATED 20 JANUARY 2017 AND TO COMPLY WITH THE

ENDANGERED SPECIES ACT, THE FOLLOWING MEASURES SHALL BE IMPLEMENTED:

DURING THE HAWAIIAN HOARY BAT (LASIURUS CINEREUS SEMOTUS) PUPPING SEASON, 1 JUNE TO 15 SEPTEMBER, THERE SHALL BE NO CUTTING OR TRIMMING OF ANY TREE OVER 15 FEET TALL.

IF A TREE FALLS ON ITS OWN THAT IS OVER 15 FEET, CONTRACTOR MAY REMOVE THE TREE.

IN CASE OF AN EMERGENCY SITUATION (E.G. TREE OVER 15 FEET THREATENING A POWER LINE), CONTRACTOR MUST CONTACT THE DPW ENVIRONMENTAL DIVISION AT (808) 655-9189 FOR

GUIDANCE PRIOR TO CUTTING THE TREE.

TREE TRIMMING AND CUTTING NOTE:

AN INTERNATIONAL SOCIETY OF ARBORICULTURE (ISA) CERTIFIED ARBORIST SHALL BE PRESENT FOR ANY TREES THAT REQUIRE ROOT OR CANOPY CUTTING OR TRIMMING. THE CONTRACTOR SHALL

FOLLOW THE RECOMMENDATIONS FOR CUTTING OR TRIMMING OF THE ARBORIST.

THE GENERAL CONTRACTOR SHALL HIRE AN INDEPENDANT CERTIFIED ARBORIST THAT IS NOT AN

EMPLOYEE OF THE LANDSCAPE CONTRACTOR OR GENERAL CONTRACTOR. THE ARBORIST SHALL

HAVE MINIMUM 5-YEARS EXPERIENCE.

NOTES:

1. FOR DEMOLITION AND REMOVAL OF ELECTRICAL FACILITIES,

SEE ELECTRICAL PLANS.

DEMOLISH AND DISPOSE OF MISCELLANEOUS STRUCTURE

REMOVE TREE

REMOVE SIGN AND POST

REMOVE CHAIN LINK FENCE, POST(S) AND FOOTING(S)

REMOVE A.C. PAVEMENT

REMOVE WHEEL STOPS

DEMOLISH CMU WALL

DEMOLISH WOODEN DECK

DEMOLISH CONCRETE CURB

DEMOLISH AC CURB OR ISLAND

DEMOLISH LANDSCAPE ISLAND

DEMOLISH CONCRETE CURB AND GUTTER

CUT AND PLUG EXISTING SEWER LINE. DEMOLISH, REMOVE AND BACKFILL SEWER LINE

AND MANHOLE(S)

CUT AND PLUG EXISTING WATER LINE. DEMOLISH AND REMOVE EXISTING WATER LINE

AND BACKFILL. SEE DETAIL A10 SHEET C-504.

DEMOLISH LANDSCAPE PLANTER

DEMOLISH AND REMOVE TRASH ENCLOSURE

DEMOLISH CONCRETE PAD

REMOVE AND SALVAGE CONCRETE JERSEY BARRIERS

REMOVE AND SALVAGE CONTAINERS/SHEDS

REMOVE AND REPLACE WATER VALVE AND WATER VALVE BOX IN PLACE. SEE UTILITY

PLAN

DEMOLISH AND DISPOSE OF CONCRETE SWALE

EXIST. SOIL STOCKPILE - CONTRACTOR TO SAMPLE STOCKPILE SOIL AND PROVIDE

SAMPLING RESULTS TO THE CONTRACTING OFFICER PER THE PROJECT

SPECIFICATIONS. REFER TO THE PROJECT SPECIFICATIONS FOR HANDLING OF SOILS

AFTER TESTING.

DEMOLISH DRAIN LINE AND HEADWALL(S)

THRIFT SHOP DONATION CENTER TO BE RELOCATED DURING CONSTRUCTION BY DPW.

RELOCATE TREE

KEY NOTES

LEASE BOUNDARY LINE

EXISTING DRAIN LINE

EXISTING SEWER LINE

EXISTING WATER LINE

STRUCTURE TO BE

DEMOLISHED

OBJECT TO BE REMOVED

AND/OR DEMOLISHED

OBJECT TO BE DEMOLISHED

LEGEND

LIMIT OF AC PAVEMENT TO

BE DEMOLISHED

KEY MAP

NOT TO SCALE

EXIST. ELEC. TO

BE DEMOLISHED

SEE ELEC. PLANS

DEMOLITION PLAN 3

SCALE: 1" = 20'A1

0 20' 40'

SCALE: 1" = 20'

PLAN NORTH

A2

AM

-0

- R

EM

O

VE

B

ID

O

PT

IO

N

F R

O M

C O

N

TR

AC

T

6/

/2

A2

U, .

No. 15480-C

ENGINEER

PROFESSIONAL

LICENSED

S A.

A

HAW II

HM.

AN

Y RA

R

K. C

EXPIRATION DATE OF THE LICENSE 4/30/2024

STAFF

ONLY

STAFF

ONLY

STAFF

ONLY STAFF

ONLYSTAFF

ONLYSTAFF

ONLYSTAFF

ONLYSTAFF

ONLYSTAFF

ONLYSTAFF

ONLYSTAFF

ONLYSTAFF

ONLYSTAFF

ONLYSTAFF

ONLYSTAFF

ONLYSTAFF

ONLYSTAFF

ONLYSTAFF

ONLY

STAFF

O

N

LY

STAFF

O

N

LY

STAFF

O

N

LY

STAFF

O

N

LY

STAFF

O

N

LY

STAFF

O

N

LY

ST

AF

F O

N

LY

ST

AF

F O

N

LY

ST

AF

F O

N

LY

ST

AF

F O

N

LY

ST

AF

F O

N

LY

STAFF

ONLY

STAFF

ONLY

STAFF

ONLY

STAFF

ONLY

STAFF

ONLY

STAFF

ONLY

STAFF

O

N

LY

25 34 1

A

E

F

D

C

B

ULRICH WAY

KAIONA

AVENUE

IK

EL

EA

S

T

KUAIKUA STREET

224.55

D

ES

IG

N

C O

M

PL

ET

E

SU

BM

IT

TA

L

SC

H

O

FI

EL

D

B

AR

R

AC

KS

, H

AW

AI

I

FY

M

C A

PN

C H

IL

D

D

EV

EL

O

PM

EN

T C

EN

TE

R

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

A

B

C

D

E

F

G

H

J

K

L

M

N

P

SU

BM

IT

TE

D B

Y:

C H

EC

KE

D B

Y:

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

IS

SU

E D

AT

E:

SI

ZE

M

AR

K

D

ES

C R

IP

TI

O N

D

AT

E

SHEET ID

US Army Corps of Engineers

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

P:

\2

9\

-0

FY

C

D C

S C

H O

FI

EL

D B

AR

R

AC

KS

\C

IV

IL

\D

W G

\P N

1_ C

D C

_S B_

C S1

.D

W G

6/

/2

:5 3:

A

M

PL

O T

D

AT

E:

FI

LE

P

AT

H

FT

. S

H

AF

TE

R

, H

AW

AI

I

H O

N O

LU

LU

D

IS

TR

IC

T

H O

'O H

U I'I

A

- J

V

BI

SH

O P

ST

, S

U

IT

E

H

O N

O

LU

LU

H

AW

AI

I 9

ST

AF

F

ST

AF

F

R . C

H

AR

/1

6/

AN

SI

D

50'

50'

CHILD DEVELOPMENT CENTER

SEE ARCHITECTURE PLANS

PLAYGROUND AREA I

FOR SURFACING SEE LANDSCAPE PLANS.

FOR CONC. SUBSLAB SEE LANDSCAPE

PLANS FOR DETAILS, SHT. LS506

26' 26'±

LEASE BOUNDARY LINE

NEW CHAIN LINK FENCE

NEW RETAINING WALL WITH CHAIN

LINK FENCE, HEIGHT PER PLANS

NEW ASPHALT CONCRETE PAVEMENT

NEW CONCRETE PAVEMENT

LEGEND

LIMIT OF WORK

TEMPORARY

BENCH MARK

STA 22

MAG NAIL

ELEV.=899.58

N 116,678.23 E 1,619,315.23

FENCING NOTES:

1. ALL FENCING MUST BE VINYL COATED, COLOR GREEN,

CHAIN-LINK SECURITY TYPE MINIMUM 4' HIGH AT THE PLAY

AREA PERIMETER AND 4' HIGH TO SUB-DIVIDE PLAY AREAS BY

AGE GROUP.

2. THE GUIDE WIRE AT THE BOTTOM AND THE WIRE FASTENERS

USED TO SECURE THE FENCE FABRIC TO THE POLES, TOP

RAIL, ETC. SHALL ALSO BE VINYL COATED.

3. FENCING WILL HAVE GATES BETWEEN THE PLAY AREAS.

4. BOLT THREADS, NUTS, AND ENDS OF WIRE FASTENERS

SHALL FACE AWAY FROM THE PLAYGROUNDS.

5. WHERE FENCE FABRIC BOLT THREADS AND NUTS ARE

REQUIRED TO FACE A PLAYGROUND (GENERALLY BETWEEN

PLAY AREAS), BOLTS WILL BE TRIMMED TO NO MORE THAN

TWO EXPOSED THREADS AND SHARP EDGES WILL BE

DRESSED WITH A FILE.

6. ALL WIRE FASTENERS USED TO SECURE THE FENCE FABRIC

TO PIPING (POLES, ETC.), WHERE THE CUT ENDS FACE AN

OUTDOOR ACTIVITY AREA, WILL BE FLUSH CUT TO REDUCE

THE INTRODUCTION OF CUTTING EDGES ON THE ENDS OF

THE WIRES, AND WILL BE POINTED DOWNWARD.

7. A TOP RAIL IS REQUIRED ON THE FENCE.

8. FENCING MUST COMPLY WITH THE CURRENT VERSION OF

ASTM F-2049.

9. PROVIDE EXIT GATES WITH ADULT CONTROLLED SECURING

DEVICE TO ALLOW ACCESS FOR EMERGENCY AND

MAINTENANCE VEHICLES.

G

EN

ER

AL

S

IT

E

PL

AN

26'

26'

26'

26'

5 ADA ACCESSIBLE

STALLS (9'x18.5')

WITH AISLES

APPROX. LEASE

BOUNDARY LINE

EXIST. CHAIN LINK FENCE

AT DETENTION BASIN TO

REMAIN.

PARKING AREA 2

58 PARKING STALLS

(16 - 9' x 24' DIAG.)

(42 - 9' x 18.5')

TRASH ENCLOSURE SEE

ARCHITECTURAL PLANS

MECHANICAL YARD

SEE MEP PLANS

EXIST. MECHANICAL

YARD TO REMAIN

FIRE PROTECTION

ROOM (FPR)

SEE ARCHITECTURAL

AND MEP PLANS

4-FT. HIGH MAX. RETAINING

WALL TOPPED WITH 4-FT. HIGH

CHAIN LINK FENCE

SEE STRUCTURAL PLANS

GRADE ADJUSTMENT WALL

SEE STRUCTURAL PLANS

FIRE WATER TANK

(25'x35') SEE MEP PLANS

PLAYGROUND AREA II

FOR SURFACING SEE LANDSCAPE PLANS.

FOR CONC. SUBSLAB SEE LANDSCAPE

PLANS FOR DETAILS, SHT. LS506

50-FT EGRESS

FROM BUILDING

50-FT EGRESS

FROM BUILDING

CONC.

WALKWAY

CONC.

WALKWAY

MATCH EXIST. AC PAVEMENT

AND PROVIDE SMOOTH

RIDING CONNECTION

4' HIGH CHAIN LINK FENCE

SEE ARCHITECTURAL

PLANS

APPROX. LEASE

BOUNDARY LINE

EXIST. EDGE

OF PAVT.

EXIST. EDGE

OF PAVT.

SC 29

MAG NAIL

ELEV=898.23

N 116,861.23 E 1,619,445.36

GATE

ACCESS,

TYP.

GATE

ACCESS, TYP.

50-FT

EGRESS

FROM

BUILDING

APPROX. LEASE

BOUNDARY LINEGATE

ACCESS

CONC. WALKWAY,

TYP.

EXIST. EDGE

OF AC PAVT.

ELECTRICAL

TRANSFORMER PAD

SEE MEP PLANS

ELECTRICAL

SWITCH PAD

SEE MEP PLANS

GREASE INTERCEPTOR

SEE MEP PLANS

12' WIDE DUAL

GATE SERVICE

ACCESS, TYP.

24' WIDE DRIVEWAY

APRON

BUILDING IDENTIFICATION

SIGN. SEE ARCHITECTURAL

PLANS

NEW CONC. MEDIAN

WALKWAY, TYP.

148' LIMIT OF WORK

LIMIT OF WORK

DRAINAGE

SWALE

RESTORE EXIST. CONC.

eCURB AND GUTTER FOR

NEW ELECTRICAL WORK

3'

STA. 4+64.56

L SWALE

N 116,693.6187 E 1,619,515.2208

STA. 0+00

L SWALE

N 116,361.2201 E 1,619,810.6416

C

C

PARKING AREA 1

66 PARKING STALLS

(66 - 9' x 18.5')

INCLUDES 5 ACCESSIBLE

STALLS WITH AISLES AND

1 LOADING ZONE (29' x 20'-6")

PROVIDE NEW CONC.

ENTRY AT BOAT SHED

CS1010 40' 80'

SCALE: 1" = 40'

MATCH EXIST. AC PAVEMENT

AND PROVIDE SMOOTH

RIDING CONNECTION

215°25'02" 224.55

BACKSIGHT

9°

'4

9"

.3

HO

RI

ZO

NT

AL

C

O

NT

RO

L

TI

E

ST

A

T

O G

RI

D

A5

RELOCATED SIGN FOR B2108

"OUTDOOR RECREATION".

MATCH EXIST. FINISH, ELEVATION

AND FOOTING SIZE. SEE DET. C-508

GATE, TYP.

GATE, TYP.

GATE, TYP.

GATE TYP.

GATE TYP.

GATE TYP.

GATE TYP.

GENERAL SITE PLAN

SCALE: 1" = 40'A1

PLAN NORTH

PLAYGROUND AREA III

FOR SURFACING SEE

LANDSCAPE PLANS. FOR

CONC. SUBSLAB SEE

LANDSCAPE PLANS FOR

DETAILS, SHT. LS506

A2

A2

AM

-0

- R

EM

O

VE

B

ID

O

PT

IO

N

F R

O M

C O

N

TR

AC

T

6/

/2

U, .

No. 15480-C

ENGINEER

PROFESSIONAL

LICENSED

S A.

A

HAW II

HM.

AN

Y RA

R

K. C

EXPIRATION DATE OF THE LICENSE 4/30/2024

STAFF

ONLY

STAFF

ONLY

STAFF

ONLY STAFF

ONLYSTAFF

ONLYSTAFF

ONLYSTAFF

ONLYSTAFF

ONLYSTAFF

ONLYSTAFF

ONLYSTAFF

ONLYSTAFF

ONLYSTAFF

ONLYSTAFF

ONLYSTAFF

ONLYSTAFF

ONLYSTAFF

ONLYSTAFF

ONLY

ST

AF

F O

N

LY

ST

AF

F O

N

LY

ST

AF

F O

N

LY

ST

AF

F O

N

LY

ST

AF

F O

N

LY

STAFF

ONLY

STAFF

ONLY

STAFF

ONLY

STAFF

ONLY

STAFF

ONLY

STAFF

ONLY

STAFF

O

N

LY

STAFF

O

N

LY

STAFF

O

N

LY

STAFF

O

N

LY

STAFF

O

N

LY

STAFF

O

N

LY

STAFF

ONLY

STAFF

ONLY

STAFF

ONLY

STAFF

ONLY

STAFF

O

N

LY

25 34 1

A

E

F

D

C

B

ULRICH WAY

KAIONA

AVENUE

IK

EL

EA

S

T

KUAIKUA STREET

D

ES

IG

N

C O

M

PL

ET

E

SU

BM

IT

TA

L

SC

H

O

FI

EL

D

B

AR

R

AC

KS

, H

AW

AI

I

FY

M

C A

PN

C H

IL

D

D

EV

EL

O

PM

EN

T C

EN

TE

R

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

A

B

C

D

E

F

G

H

J

K

L

M

N

P

SU

BM

IT

TE

D B

Y:

C H

EC

KE

D B

Y:

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

IS

SU

E D

AT

E:

SI

ZE

M

AR

K

D

ES

C R

IP

TI

O N

D

AT

E

SHEET ID

US Army Corps of Engineers

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

P:

\2

9\

-0

FY

C

D C

S C

H O

FI

EL

D B

AR

R

AC

KS

\C

IV

IL

\D

W G

\P N

1_ C

D C

_S B_

C S1

A.

D W

G 6/

/2

:5

5:

A M

PL

O

T D

AT

E:

FI

LE

P

AT

H

FT

. S

H

AF

TE

R

, H

AW

AI

I

H O

N O

LU

LU

D

IS

TR

IC

T

H O

'O H

U I'I

A

- J

V

BI

SH

O P

ST

, S

U

IT

E

H

O N

O

LU

LU

H

AW

AI

I 9

ST

AF

F

ST

AF

F

R . C

H

AR

/1

6/

AN

SI

D

APPROX. LEASE

BOUNDARY LINE

EXIST. CHAIN LINK FENCE

AT DETENTION BASIN TO

REMAIN.

PARKING AREA 1

66 PARKING STALLS

(66 - 9' x 18.5')

INCLUDES 5 ACCESSIBLE

STALLS WITH AISLES AND

1 LOADING ZONE (29' x 20'-6")

BID OPTION 1

PARKING AREA 2

(EXTENDED)

70 PARKING STALLS

(16 - 9' x 24' DIAG.)

(54 - 9' x 18.5')

TRASH ENCLOSURE SEE

ARCHITECTURAL PLANS

MECHANICAL YARD

SEE MEP PLANS

EXIST. MECHANICAL

YARD TO REMAIN

FIRE PROTECTION

ROOM (FPR)

SEE ARCHITECTURAL

AND MEP PLANS

BID OPTION 2 THRIFT SHOP

PARKING IMPROVEMENTS

PROVISIONAL PARKING AREA

19 STALLS ( 9' x 18.5')

4-FT. HIGH MAX. RETAINING

WALL TOPPED WITH 4-FT. HIGH

CHAIN LINK FENCE

SEE STRUCTURAL PLANS

GRADE ADJUSTMENT WALL

SEE STRUCTURAL PLANS

FIRE WATER TANK

(25'x35') SEE MEP PLANS

50-FT EGRESS

FROM BUILDING

50-FT EGRESS

FROM BUILDING

MATCH EXIST. AC PAVEMENT

AND PROVIDE SMOOTH

RIDING CONNECTION

50'

CONC.

WALKWAY

PROVIDE NEW CONC.

ENTRY AT BOAT SHED

CHILD DEVELOPMENT CENTER

SEE ARCHITECTURE PLANS

26'

26'±

4' HIGH CHAIN

LINK FENCE SEE

ARCHITECTURAL

PLANS

APPROX. LEASE

BOUNDARY LINE

LEASE BOUNDARY LINE

NEW CHAIN LINK FENCE

NEW RETAINING WALL WITH CHAIN

LINK FENCE, HEIGHT PER PLANS

NEW ASPHALT CONCRETE PAVEMENT

NEW CONCRETE PAVEMENT

LEGEND

LIMIT OF WORK

EXIST. EDGE

OF PAVT.

EXIST. EDGE

OF PAVT.

215°25'02" 224.55

BACKSIGHT

237°51'57" 139.90

HORIZONTAL CONTROL TIE

9°

'4

9"

.3

HO

RI

ZO

NT

AL

C

O

NT

RO

L

TI

E

ST

A

T

O G

RI

D

A5

DRIVEWAY "A"

L STA. 0+00C

50-FT

EGRESS

FROM

BUILDING

APPROX. LEASE

BOUNDARY LINEGATE

ACCESS,

TYP.

G

EN

ER

AL

S

IT

E

PL

AN

(B

ID

O

PT

IO

N S

1, CONC.

WALKWAY, TYP.

26'

26'

26'

26'

ELECTRICAL

TRANSFORMER PAD

SEE MEP PLANS

ELECTRICAL

SWITCH PAD

SEE MEP PLANS

GREASE INTERCEPTOR

SEE MEP PLANS

12' WIDE DUAL

GATE SERVICE

ACCESS, TYP.

24' WIDE DRIVEWAY

APRON

BUILDING IDENTIFICATION

SIGN. SEE ARCHITECTURAL

PLANS

CONC. MEDIAN

WALKWAY, TYP.

198'

LIMIT OF WORK

LIMIT OF WORK

DRAINAGE

SWALE

RESTORE EXIST. CONC.

CURB AND GUTTER FOR

NEW ELECTRICAL WORK

LIMIT OF BID OPTION 1

PARKING AREA 2

(EXTENDED)

SEE SHT. CS102A

TEMPORARY

BENCH MARK

STA 22

MAG NAIL

ELEV.=899.58

N 116,678.23 E 1,619,315.23

SC 29

MAG NAIL

ELEV=898.23

N 116,861.23 E 1,619,445.36

LIMIT OF BID OPTION 2

THRIFT SHOP PARKING

IMPROVEMENTS

SEE SHT. CS102A

CONC. WALKWAY

STA. 4+64.56

L SWALE

N 116,693.6187 E 1,619,515.2208

STA. 0+00

L SWALE

N 116,361.2201 E 1,619,810.6416

C

C

3'

CS101A

MATCH EXIST. AC PAVEMENT

AND PROVIDE SMOOTH

RIDING CONNECTION

EXIST. EDGE

OF AC PAVT.

RELOCATED SIGN FOR B2108

"OUTDOOR RECREATION".

MATCH EXIST. FINISH, ELEVATION

AND FOOTING SIZE. SEE DET. C-508

MATCH EXIST. AC PAVEMENT

AND PROVIDE SMOOTH

RIDING CONNECTION

FENCING NOTES:

1. ALL FENCING MUST BE VINYL COATED, COLOR GREEN,

CHAIN-LINK SECURITY TYPE MINIMUM 4' HIGH AT THE PLAY

AREA PERIMETER AND 4' HIGH TO SUB-DIVIDE PLAY AREAS BY

AGE GROUP.

2. THE GUIDE WIRE AT THE BOTTOM AND THE WIRE FASTENERS

USED TO SECURE THE FENCE FABRIC TO THE POLES, TOP

RAIL, ETC. SHALL ALSO BE VINYL COATED.

3. FENCING WILL HAVE GATES BETWEEN THE PLAY AREAS.

4. BOLT THREADS, NUTS, AND ENDS OF WIRE FASTENERS

SHALL FACE AWAY FROM THE PLAYGROUNDS.

5. WHERE FENCE FABRIC BOLT THREADS AND NUTS ARE

REQUIRED TO FACE A PLAYGROUND (GENERALLY BETWEEN

PLAY AREAS), BOLTS WILL BE TRIMMED TO NO MORE THAN

TWO EXPOSED THREADS AND SHARP EDGES WILL BE

DRESSED WITH A FILE.

6. ALL WIRE FASTENERS USED TO SECURE THE FENCE FABRIC

TO PIPING (POLES, ETC.), WHERE THE CUT ENDS FACE AN

OUTDOOR ACTIVITY AREA, WILL BE FLUSH CUT TO REDUCE

THE INTRODUCTION OF CUTTING EDGES ON THE ENDS OF

THE WIRES, AND WILL BE POINTED DOWNWARD.

7. A TOP RAIL IS REQUIRED ON THE FENCE.

8. FENCING MUST COMPLY WITH THE CURRENT VERSION OF

ASTM F-2049.

9. PROVIDE EXIT GATES WITH ADULT CONTROLLED SECURING

DEVICE TO ALLOW ACCESS FOR EMERGENCY AND

MAINTENANCE VEHICLES.

5 ADA ACCESSIBLE

STALLS (9'x18.5')

WITH AISLES

GATE, TYP.

GATE, TYP.

GATE, TYP.

GATE

ACCESS,

TYP.

GATE TYP.

GATE TYP.

GATE TYP.

GATE TYP.

0 40' 80'

SCALE: 1" = 40'

GENERAL SITE PLAN (BID OPTIONS 1, 2 & 3)

SCALE: 1" = 40'A1

PLAN NORTH

50'

GATE

ACCESS, TYP.

PLAYGROUND AREA I

FOR SURFACING SEE LANDSCAPE PLANS.

FOR CONC. SUBSLAB SEE LANDSCAPE

PLANS FOR DETAILS, SHT. LS506

PLAYGROUND AREA II

FOR SURFACING SEE LANDSCAPE PLANS.

FOR CONC. SUBSLAB SEE LANDSCAPE

PLANS FOR DETAILS, SHT. LS506

PLAYGROUND AREA III

FOR SURFACING SEE

LANDSCAPE PLANS. FOR

CONC. SUBSLAB SEE

LANDSCAPE PLANS FOR

DETAILS, SHT. LS506

A2

A2

AM

-0

- R

EM

O

VE

B

ID

O

PT

IO

N

F R

O M

C O

N

TR

AC

T

6/

/2

U, .

No. 15480-C

ENGINEER

PROFESSIONAL

LICENSED

S A.

A

HAW II

HM.

AN

Y RA

R

K. C

EXPIRATION DATE OF THE LICENSE 4/30/2024

LYMAN ROAD

IK

EL

EA

S

T

KUAIKUA STREET

KAIONA

AVENUE

ULRICH WAY

D

ES

IG

N

C O

M

PL

ET

E

SU

BM

IT

TA

L

SC

H

O

FI

EL

D

B

AR

R

AC

KS

, H

AW

AI

I

FY

M

C A

PN

C H

IL

D

D

EV

EL

O

PM

EN

T C

EN

TE

R

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

A

B

C

D

E

F

G

H

J

K

L

M

N

P

SU

BM

IT

TE

D B

Y:

C H

EC

KE

D B

Y:

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

IS

SU

E D

AT

E:

SI

ZE

M

AR

K

D

ES

C R

IP

TI

O N

D

AT

E

SHEET ID

US Army Corps of Engineers

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

P:

\2

9\

-0

FY

C

D C

S C

H O

FI

EL

D B

AR

R

AC

KS

\C

IV

IL

\D

W G

\P N

1_ C

D C

_S B_

C G

3.

D W

G 6/

/2

:5

0:

A M

PL

O

T D

AT

E:

FI

LE

P

AT

H

FT

. S

H

AF

TE

R

, H

AW

AI

I

H O

N O

LU

LU

D

IS

TR

IC

T

H O

'O H

U I'I

A

- J

V

BI

SH

O P

ST

, S

U

IT

E

H

O N

O

LU

LU

H

AW

AI

I 9

ST

AF

F

ST

AF

F

R . C

H

AR

/1

6/

AN

SI

D

D

ES

IG

N

C O

M

PL

ET

E

SU

BM

IT

TA

L

SC

H

O

FI

EL

D

B

AR

R

AC

KS

, H

AW

AI

I

FY

M

C A

PN

C H

IL

D

D

EV

EL

O

PM

EN

T C

EN

TE

R

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

A

B

C

D

E

F

G

H

J

K

L

M

N

P

SU

BM

IT

TE

D B

Y:

C H

EC

KE

D B

Y:

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

IS

SU

E D

AT

E:

SI

ZE

M

AR

K

D

ES

C R

IP

TI

O N

D

AT

E

SHEET ID

US Army Corps of Engineers

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

P:

\2

9\

-0

FY

C

D C

S C

H O

FI

EL

D B

AR

R

AC

KS

\C

IV

IL

\D

W G

\P N

1_ C

D C

_S B_

C G

3.

D W

G 6/

/2

:5

0:

A M

PL

O

T D

AT

E:

FI

LE

P

AT

H

FT

. S

H

AF

TE

R

, H

AW

AI

I

H O

N O

LU

LU

D

IS

TR

IC

T

H O

'O H

U I'I

A

- J

V

BI

SH

O P

ST

, S

U

IT

E

H

O N

O

LU

LU

H

AW

AI

I 9

ST

AF

F

ST

AF

F

R . C

H

AR

/1

6/

AN

SI

D

BEST MANAGEMENT PRACTICES (BMP) NOTES:

1. TEMPORARY EROSION CONTROLS SHALL BE IN PLACE PRIOR TO

ANY GRADING, DEMOLITION, OR CONSTRUCTION

2. THE BMP FACILITIES SHOWN ON THIS PLAN ARE THE MINIMUM

REQUIREMENTS FOR ANTICIPATED SITE CONDITIONS AND SHALL

BE UPGRADED DURING THE CONSTRUCTION PERIOD AS NEEDED

FOR UNEXPECTED STORM EVENTS AND TO ENSURE THAT

SEDIMENT AND SEDIMENT-LADEN RUNOFF DOES NOT LEAVE THE

WORK SITE.

3. ALL POINTS OF INGRESS AND EGRESS TO THE SITE SHALL BE

PROTECTED WITH A STABILIZED CONSTRUCTION ENTRANCE.

4. PROVIDE INLET FILTER (INLET PROTECTION OR APPROVED

EQUAL) FOR ALL CATCH BASIN OPENINGS.

5. DUST CONTROL SHOULD BE APPLIED TO REDUCE DUST

EMISSIONS. THE CONTRACTOR, AT HIS OWN EXPENSE, SHALL

KEEP THE PROJECT AREA AND SURROUNDING AREA FREE FROM

DUST NUISANCE. THE WORK SHALL BE IN CONFORMANCE WITH

THE AIR POLLUTION CONTROL STANDARDS CONTAINED IN

HAWAII ADMINISTRATIVE RULES: CHAPTER 11-60, "AIR POLLUTION

CONTROL".

6. SEDIMENT BARRIERS (FILTER SOCKS) SHALL BE USED DOWN

SLOPE OF ALL DISTURBED AREAS AND ALONG THE PERIMETER

OF THE PROJECT AREA.

7. ALL STORM DRAIN INLETS ONSITE AND THOSE OFFSITE WHICH

MAY RECEIVE RUNOFF FOR THE SITE SHALL USE AN INLET

PROTECTION DEVICE.

8. STOCKPILING CONSTRUCTION MATERIAL OUTSIDE THE

DESIGNATED PROJECT AREA IS PROHIBITED.

9. STABILIZATION CONTROL

A. TEMPORARY - ALL SLOPES AND EXPOSED AREAS SHALL BE

IMMEDIATELY MULCHED OR PLANTED WHEN FINAL GRADES

ARE ESTABLISHED OR WHEN GRADING WORK WILL BE

DELAYED FOR MORE THAN TWO WEEKS AND BEFORE THE

REMOVAL OF THE PROJECT'S TEMPORARY BMPs.

B. PERMANENT - AREA WILL BE COVERED BY BUILDINGS,

CONCRETE WALKWAY OR AC PAVEMENT AND EXPOSED

AREAS SHALL BE LANDSCAPED WHEN FINAL GRADES ARE

ESTABLISHED.

MAINTENANCE NOTE:

EROSION CONTROL MEASURES SHALL BE INSPECTED IMMEDIATELY

AFTER EACH RAINFALL (0.25-IN. EVENT) AND AT LEAST DAILY

DURING PROLONGED RAINFALL. ANY REQUIRED REPAIRS SHALL BE

MADE IMMEDIATELY.

DUST CONTROL NOTE:

THE CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR THE MEASURES

IT WILL TAKE FOR THE CONTROL OF FUGITIVE DUST FROM THE WORK

SITE. THE MEASURES MAY INCLUDE BUT NOT BE LIMITED TO THE

INSTALLATION OF DUST SCREENS, WATERING OF THE SITE, FILL

MATERIAL BEING PLACED, AND DELAYING WORK IN THE WEEK THAT

PREVAILING WIND DIRECTION SHOULD SHIFT.

CONTRACTOR SHALL ADJUST THE LOCATION OF DUST FENCES AND

GATES DURING CONSTRUCTION AT NO EXPENSE TO THE GOVERNMENT.

TEMPORARY

CONSTRUCTION

ENTRANCE, TYP.

SEE DET. CG105

TEMPORARY GEOTEXTILE

FABRIC FILTER FOR ALL

EXISTING AND NEW GRATED

DRAIN INLETS WITHIN THE

PROJECT AREA, TYP.

SEE DET. CG105

TEMPORARY GEOTEXTILE

FABRIC FILTER FOR ALL

EXISTING AND NEW GRATED

DRAIN INLETS WITHIN THE

PROJECT AREA, TYP.

SEE DET. CG105

CONTRACTOR TO TAKE

APPROPRIATE

PRECAUTIONS AND

PROTECTIONS WHEN

WORKING AROUND

BUILDING 2102 TO REMAIN.

TEMPORARY FILTER

SOCK, TYP.

SEE DET. CG105

APPROX. LEASE

BOUNDARY LINE

LIMIT OF

WORK

CATCH BASIN

FILTER, TYP.

SEE DETAIL

SHT. C-501

LEGEND

EXTEND CONSTRUCTION

FENCE FOR PAVING

OPERATIONS MAINTAIN

ACCESS TO OUTDOOR

RECREATION CENTER FOR

ENTIRE DURATION OF

CONSTRUCTION PHASE

OPERATIONS TO ALLOW

ACCESS AT ALL TIMES

EXIST. GRASS

SWALE

EXIST. ROAD SIDE

DIVERSION SWALE

TO DETENTION

BASIN

ROCK CONSTRUCTION ACCESS

FOR INGRESS/EGRESS

LIMIT OF WORK

PAVING PHASE

FILTER SOCK

TEMPORARY DUST FENCE

TEMPORARY MIRAFI GEOTECHNICAL FABRIC

FILTER FOR GRATED DRAIN INLETS

CURB INLET PROTECTION

EXISTING BUILDING

DIRECTION OF SURFACE FLOW

LEASE BOUNDARY LINE

CATCH BASIN FILTER, TYP.

SEE DET. CG105

H.P.

PAVING PHASE

CLOSES ORC

PARKING LOTS

TEMPORARY FILTER

SOCK, TYP.

SEE DET. CG105

LIMIT OF WORK

LIMIT OF

WORK

LIMIT OF WORK

LIMIT OF

WORK

APPROX. LEASE

BOUNDARY LINE

TEMPORARY 10' HIGH

CONSTRUCTION/DUST

FENCE AT PROJECT

PERIMETER, TYP.

SEE DET. CG105

ACCESS NOTES:

1. THE CONTRACTOR SHALL PROVIDE ACCESS TO THE ORC AND

MAINTENANCE FACILITY (BUILDINGS 2110 AND 2106) DURING

CONSTRUCTION.

2. CONTRACTOR SHALL MAINTAIN ALL DUST FENCE AND

VEHICULAR AND PEDESTRIAN GATES THROUGHOUT THE

DURATION OF THE PROJECT TO PROVIDE CONTINUOUS

ACCESS TO ADJACENT FACILITIES TO REMAIN OPEN DURING

CONSTRUCTION.

ER

O

SI

O

N A

N D

S

ED

IM

EN

T C

O N

TR

O

L

PL

AN

(B

AS

E

BI

D

TO DETENTION

BASIN

LIMIT OF BID

OPTION 1

LIMIT OF BID

OPTION 2

TEMPORARY 10' HIGH

CONSTRUCTION/DUST

FENCE AT PROJECT

PERIMETER, TYP.

SEE DET. CG105

CG10340' 80'

SCALE: 1" = 40'

EROSION AND SEDIMENT CONTROL PLAN

SCALE: 1" = 40'A1

PLAN NORTH

A2

A2

AM

-0

- R

EM

O

VE

B

ID

O

PT

IO

N

F R

O M

C O

N

TR

AC

T

6/

/2

U, .

No. 15480-C

ENGINEER

PROFESSIONAL

LICENSED

S A.

A

HAW II

HM.

AN

Y RA

R

K. C

EXPIRATION DATE OF THE LICENSE 4/30/2024

ro of lin e

STAFF

ONLY

STAFF

ONLY

STAFF

ONLY

STAFF

ONLY

STAFF

ONLY

STAFF

ONLY

STAFF

ONLY

S T

A F

F O

N L Y

S T

A F

F O

N L Y

S T A

F F

O N

LY

S

T A

F F

O N

LY

S

T A

F F

O N

LY

S

T A

F F

O N

LY

S

T A

F F

O N

LY

S

T A

F F

O N

LY

S

T A

F F

O N

LY

S

T A

F F

O N

LY

S

T A

F F

O N

LY

S

T A

F F

O N

LY

S

T A

F F

O N

LY

S

T A

F F

O N

LY

S

T A

F F

O N

LY

S

T A

F F

O N

LY

S

T A

F F

O N

LY

S

T A

F F

O N

LY

STAFF

ONLY

STAFF

ONLY

STAFF

ONLY

STAFF

ONLY

STAFF

ONLY

S T

A F

F O

N L Y

S T

A F

F O

N L Y

S T

A F

F O

N L Y

S T

A F

F O

N L Y

S T

A F

F O

N L Y

S T

A F

F O

N L Y

REF

A B E F

K U

A

IK

U A

S T

K A

IO

N A A

V E

PROTECTED

TREE

EXIST

ENCL

SEE CIVIL FOR PARKING

COUNTS

AND BID OPTIONS

TRASH

ENCLOSURE

50' SETBACK

FROM BUILDING

50' SETBACK

FROM BUILDING

50' SETBACK

FROM BUILDING

S

E T

B A

C K

F R

O M

B U

IL

D

IN

G

S

E T

B A

C K

F R

O M

B U

IL

D

IN

G

APPROXIMATE LOCATION

OF EXISTING RESIDENTIAL

AREA

FIRE ACCESS

LANE

MECH

YARD

A-115

G14

E N

T R

Y

WATER

TANK

(25' X 35')

GI

ELEC

PAD

BFP

DC

BUILDING

IDENTIFICATION

SIGN

AE502

F15 LOADING

DRIVEWAY

THRIFT SHOP

EXTENT OF ADDITIONAL

PARKING, BID OPTION,

SEE CIVIL

B2108

OUTDOOR REC

BLDG 2102

9' - 0"

ABA PARKING

SIGNS TYP. SEE CIVIL FOR PARKING COUNTS

AND BID OPTIONS

PLAN

NORTH

0 20' 40' 80' 04/30/2024

A

ARCHITECT

PROFESSIONAL

LICENSED

W A

H

A.

U.

I

I S.

M

A J

No. 8352

L.

ES TS

N O

E

License Expiration Date

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

P L O

T D

A T

E

F

IL

E P

A T

H

I:

\N

E W

G \2

-0

F

Y C

D C

S c h o fi e ld

B a rr a c k s -J im \0

-F

IN

A

L \P

N C

D C

S

B M

M I_

R V

T A

.r v t

/1

/2

:0

:2

P

M

A-101

A R

C H

IT

E

C T

U R

A L S

IT

E

P L A

N

S C

H O

F

IE

L D

B A

R R

A C

K S

H

A W

A

II

H O

N O

L U

L U

D

IS

T R

IC

T

F T

S

H A

F T

E R

H

A W

A

II

B U

R N

S

M C

D O

N N

E L L G

J S

T O

N E

E

IG

N A

C

IO

R

IN

O U

Y E

/1

/2

D E

S

IG

N C

O M

P L E

T E

S U

B M

IT

T

A L

F Y

M

C A

P N

C

H

IL

D D

E V

E L O

P M

E N

T C

E N

T E

R

B

IS

H

O P

S T

R E

E T

S U

IT

E

H O

N O

L U

L U

H

I A

1" = 40'-0"A10

SITE PLAN

A M-

RE

MO

VE

B

ID

O

PT

IO

N

3 F

RO

M

CO

NT

RA

CT

/27 /20

S E

E F

A F

O R

C O

N T

IN

U

A T

IO

N

F F F

FF

CO

E T

F

OUTREACH/TRANSITIONAL

CARE ACTIVITY ROOM

PRESCHOOL/PRE-K/KINDERGARTEN

ACTIVITY ROOM

COMMUNICATIONS 1

EXT. STORAGE

KITCHEN

ELECTRICAL ROOM 2

LAUNDRY ROOM

MECHANICAL

STORAGE

121B

STORAGE

124B

TOILET

PRESCHOOL TOILET

121A

HALLWAY

DRY FOOD STORAGE

113A

STORAGE

118B

CENTRAL STORAGE 2

OUTREACH TOILET

118A

FF

LOC

ETET

ET

N A

C F

A C

A M

P

S P

V S

W F

FPC

F

D

EXT. STORAGE

FIRE PUMP RM

FIRE ALARM

NOT REQUIRED

WP

MECH YARD

JPC

A2

PROVIDE CEILING MOUNTED SPEAKERS AND

SMOKE DETECTION AS REQUIRED TO

ACHIEVE DESIGN CRITERIA.

PROVIDE CEILING MOUNTED SPEAKERS AND

CLEAR STROBES AS REQUIRED TO ACHIEVE

DESIGN CRITERIA.

PROVIDE CEILING MOUNTED SPEAKER, CLEAR

STROBES AND SMOKE DETECTION AS REQUIRED

TO ACHIEVE DESIGN CRITERIA.

PROVIDE WEATHERPROOF WALL MOUNTED

SPEAKERS AS REQUIRED TO ACHIEVE DESIGN

CRITERIA.

NO HATCH

PROVIDE CEILING MOUNTED SPEAKERS AS

REQUIRED TO ACHIEVE DESIGN CRITERIA.

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

KEY PLAN

A B C

D

E

P L O

T D

A T

E

F

IL

E P

A T

H

C

R e v it P ro je c ts

\1 F

C e n tr a l_ m rm a ff e i.

rv t

/1

/2

:2

:5

P

M

FA103

F

IR

E A

L A

R M

F L O

O R

P L A

N

A R

E A

C

S C

H O

F

IE

L D

B A

R R

A C

K S

H

A W

A

II

H O

N O

L U

L U

D

IS

T R

IC

T

F T

S

H A

F T

E R

H

A W

A

II

H O

'O H

U I'I

A

J V

A D

A H

L

M M

A F

F E

I

A M

O O

R E

/1

/2

A M

E N

D M

E N

T

F Y

M

C A

P N

C

H

IL

D D

E V

E L O

P M

E N

T C

E N

T E

R

B

IS

H

O P

S T

S

U

IT

E

H O

N O

L U

L U

H

A W

A

II

SCALE: 1/8" = 1'-0"

A7

FIRE ALARM FLOOR PLAN - AREA C

0 4' 8' 16'

1. PROVIDE SMOKE DETECTION OVER FMCU, AMP, AND NAC

PANELS.

2. PROVIDE WEATHER PROOF HORN/STROBE OVER FDC

CONNECTION.

3. MONITOR FLOW AND TAMPER SWITCHES. REFER TO FIRE

SUPPRESSION CONTRACTOR'S DESIGN FOR QUANTITY

AND LOCATION.

4. MONITOR KITCHEN HOOD SUPPRESSION SYSTEM IN THE

KITCHEN. COORDINATE CONNECTION AND FINAL LOCATION

WITH KITCHEN EQUIPMENT CONTRACTOR.

5. PROVIDE WEATHERPROOF STROBE FOR PLAYGROUND.

GENERAL SHEET NOTES

SHEET KEYNOTES

LEGEND

1. REFER TO FA001 FOR GENERAL NOTES, DESIGN

CRITERIA, ABBREVIATIONS AND SYMBOLS.

PLAN

NORTH

A

A M

-0

F

IR

E

P R

O T

E C

T

IO

N R

E V

IS

IO

N S

/2

/2

06/17/2022

POWER CIRCUIT

VISIBLE NOTIFICATION APPLIANCE

CIRCUIT (CLASS A)

AUDIBLE NOTIFICATION APPLIANCE

CIRCUIT (CLASS A)

SIGNALING LINE CIRCUIT (CLASS A)

INITIATING DEVICE CIRCUITS (CLASS B)

1. THE FIRE ALARM ONE-LINE DIAGRAM SHOWS THE INTENT

OF THE FIRE ALARM INFRASTRUCTURE. NOT ALL DEVICES

ARE SHOWN. PROVIDE THE QUANTITY OF DEVICES AS

REQUIRED TO COMPLY WITH NFPA 72, UFC 3-600-01, UFC

4-021-01, STANDARD DESIGN CRITERIA FOR CHILD

DEVELOPMENT CENTERS, ARMY STANDARD FOR CHILD

DEVELOPMENT CENTERS, ECB 2018-17, AND CONTRACT

DOCUMENTS.

2. EACH FLOW AND TAMPER SWITCH SHALL REPORT BACK TO

THE FIRE ALARM CONTROL UNIT WITH A SEPARATE

ADDRESS. GROUPED SWITCHES ON ONE ADDRESS ARE NOT

ACCEPTABLE.

1. MOUNT RADIO TRANSCEIVER ANTENNA PER

MANUFACTURERS RECOMMENDATION. PROVIDE #6 BARE

COPPER TO 3/4" X 10'-0" COPPER CLAD GROUND ROD AND

TO BUILDING COUNTERPOISE, AND LIGHTNING ARRESTOR

KIT.

2. RED, LOCKABLE BREAKER LABELED "FIRE PROTECTION AND

LIFE SAFETY EQUIPMENT" PROVIDED BY DIVISION 26. SEE

ELECTRICAL PLANS FOR ADDITIONAL INFORMATION.

3. QUANTITY AND LOCATION BY CONTRACTOR'S DESIGN TO

MEET DESIGN CRITERIA.

4. REFER TO FIRE SUPPRESSION DRAWINGS FOR QUANTITY

AND / OR LOCATIONS OF DEVICE(S).

5. REFER TO FIRE ALARM PLANS FOR QUANTITY AND / OR

LOCATIONS OF DEVICE(S).

6. PROVIDE ADDRESSABLE INPUT AND/OR OUTPUT MODULE(S)

AS REQUIRED TO ACHIEVE THE FUNCTIONALITY INDICATED

IN THE FIRE ALARM MATRIX.

7. PROVIDE ADDITIONAL BOOSTER PANELS AS REQUIRED PER

CONTRACTOR'S DESIGN.

8. PROVIDE ADDITIONAL AMPLIFIERS AS REQUIRED PER

CONTRACTOR'S DESIGN.

9. PROVIDE SUPPLY DUCT SMOKE DETECTORS FOR DIRECT

SHUT DOWN FOR AIR HANDLING UNITS OVER 2,000 CFM.

SHUTDOWN THROUGH THE EMCS/DDC IS NOT PERMITED.

REFERENCE MECHANICAL DRAWINGS FOR QUANTITY AND

LOCATION.

10. EXTERIOR WP HORN STROBE OVER FDC

11. EXTERIOR WP FIRE ALARM/MASS NOTIFICATION SPEAKERS

12. EXTERIOR WP STROBE

13. 24 VDC FROM FMCU OR NAC PANEL

14. EXTERIOR TANK DEVICES. REFER TO FIRE SUPPRESSION

DRAWINGS FOR QUANTITY AND/OR LOCATIONS OF DEVICES.

15. WHERE THE INDICATING LIGHTS ON THE SMOKE DETECTOR

ARE NOT VISIBLE, PROVIDE REMOTE INDICATOR WITH

INDICATING LIGHT VISIBLE FROM THE FLOOR.

16. PRESSURE RELIEF DAMPER. 120 VAC PROVIDED BY

ELECTRICAL.

17. PROVIDE QUANTITY OF DUCT SMOKE DETECTORS AND

CONNECTION TO SMOKE OR FIRE/SMOKE DAMPERS AS

REQUIRED BY THE MECHANICAL DRAWINGS. SEE

MECHANICAL SHEETS M-102 THROUGH M-106.

FMCU

FAC

S P

VS WF

F

BATT

SS

120 VAC

S

BATT SS

SS

NAC

BATT

SS

120 VAC

AMP

CO

AOM

AOMS

S

RL

24 V FROM

VFD/STARTER

TO ENABLE

INPUT ON

VFD/STARTER

AIM

AIMAIMAIM

120 VAC 2

120 VAC 2

BATT

SYNCHRONIZATION

CIRCUIT TO NEXT NAC

PANEL

WP

AOM

LOC 5

5ET

S

WP

3 11

AIM

10 5 12

WP

6 6

FROM KITCHEN

HOOD

SUPPRESSION

SYSTEM

AIM

SS

LS

L

AIM

FPC

AOM

FROM DOOR POWER

SUPPLY JUNCTION BOX.

REFER TO TY501 AND

TY701 FOR ADDITIONAL

INFORMATION.

AOM

FROM EMERGENCY

LIGHTING EMERGENCY

CONTROL RELAY. SEE

SHEET EL504 DETAIL B12

FOR ADDITIONAL

INFORMATION.

AOMS

S

RL

FIRE/SMOKE

DAMPER

120 VAC

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

P L O

T D

A T

E

F

IL

E P

A T

H

C

R e v it P ro je c ts

\1 F

C e n tr a l_ a q u e v e d o b u rn s m c d .c o m

.r v t

/5

/2

:1

:5

P M

FA601

F

IR

E A

L A

R M

O N

E -L

IN

E

D

IA

G R

A M

S C

H O

F

IE

L D

B A

R R

A C

K S

H

A W

A

II

H O

N O

L U

L U

D

IS

T R

IC

T

F T

S

H A

F T

E R

H

A W

A

II

H O

'O H

U I'I

A

J V

A D

A H

L

M M

A F

F E

I

A M

O O

R E

/1

/2

A M

E N

D M

E N

T

F Y

M

C A

P N

C

H

IL

D D

E V

E L O

P M

E N

T C

E N

T E

R

B

IS

H

O P

S T

S

U

IT

E

H O

N O

L U

L U

H

A W

A

II

NTSSCALE:

A1

FIRE ALARM ONE-LINE DIAGRAM

GENERAL SHEET NOTES

SHEET KEYNOTES

LEGEND

A

A M

-0

F

IR

E

P R

O T

E C

T

IO

N R

E V

IS

IO

N S

/2

/2

FP FIRE PUMP

GPM GALLONS PER MINUTE

HSCP HORIZONTAL, SPLIT-CASE

JP JOCKEY PUMP

(M) MECHANICALLY SUPERVISED

MSC MULTI-STAGE CENTRIFUGAL

(NC) NORMALLY CLOSED

NFPA NATIONAL FIRE PROTECTION ASSOCIATION

NO NORMALLY OPEN

(S) ELECTRICALLY SUPERVISED

SQ FT SQUARE FOOT

UFC UNIFIED FACILITIES CRITERIA

UL UNDERWRITERS LABORATORY

UNO UNLESS NOTED OTHERWISE

FIRE PROTECTION SPRINKLER SYSTEM DESIGN CRITERIA

PRESSURE RELIEF VALVE

OUTSIDE SCREW AND YOKE

VALVE (OS&Y)

VALVE

BACKFLOW PREVENTER RPZ

TYPE

INDICATING BUTTERFLY VALVE

FLOW TEST HEADER

CHECK VALVE

AUTOMATIC DRAIN VALVE

FIRE DEPARTMENT

CONNECTION

PRESSURE GAUGE

SIGHT GLASS

FLOW SWITCH

FIRE SUPPRESSION LEGEND FIRE SUPPRESSION ABBREVIATIONS FIRE SUPPRESSION DESIGN CRITERIA FIRE SUPPRESSION GENERAL NOTES

DRAIN PIPING

PIPING SYMBOLS

THRUST BLOCK

AUTOMATIC AIR RELEASE

VALVE

RISER LOCATION

HAZARD CLASSIFICATION

NOTE 1: PROVIDE 200 ºF RATED SPRINKLERS IN MECHANICAL, ELECTRICAL, FIRE PROTECTION AND COMMUNICATION ROOMS.

NOTE 2: HOSE DEMAND SUPPLIED FROM BASE HYDRANT SYSTEM NOT FROM PROJECT FIRE PUMPS.

MARK

WET

SYSTEM

TYPE

WET

REMOTE

AREA

SQ FT

HOSE

DEMAND

GPM

TEMP

RATING (ºF)

TYPE / FINISH

(CEILINGS)

ORDINARY

ORDINARY

QUICK RESPONSE WHITE

RECESSED PENDENT

QUICK RESPONSE

BRASS UPRIGHT

NOTES

1,2

0.10

DENSITY

GPM/SQ FT

0.20

MAXIMUM AREA

PER HEAD

SQ FT

LIGHT HAZARD

ORDINARY HAZARD

ADDITIONAL CODE

REFERENCE

SPRINKLER CHARACTERISTICS

MINIMUM

K-FACTOR

5.6

8.0

FIRE SUPPRESSION SYSTEM

WET SYSTEM

ELBOW UP OR DOWN

SYSTEM PIPING

1. SERVE THE FIRE SUPPRESSION SYSTEM FROM THE NEW

FIREWATER STORAGE TANK. PERFORM A HYDRANT

FLOW TEST, AND INCORPORATE THIS TEST INTO THE

CALCULATIONS DEMONSTRATE ADEQUATE HOSE

STREAM DEMANDS AND TANK REFILL ARE AVAILABLE.

HYDRANT FLOW TESTING SHALL BE IN ACCORDANCE

WITH NFPA 291, AND THE RESULTS OF THE TESTING

SHALL BE SUBMITTED AS INDICATED IN NFPA 291 FIGURE

4.11.2.

FOR INFORMATION ONLY: FLOW TEST 1

NO PUMPS RUNNING:

DATE 12/08/2020

STATIC 59 PSI

RESIDUAL 27 PSI

FLOW 750 GPM

FOR INFORMATION ONLY: FLOW TEST 2

1 PUMP RUNNING:

DATE 12/08/2020

STATIC 59 PSI

RESIDUAL 32 PSI

FLOW 750 GPM

FOR INFORMATION ONLY: FLOW TEST 3

3 PUMPS RUNNING:

DATE 12/08/2020

STATIC 59 PSI

RESIDUAL 35 PSI

FLOW 805 GPM

2. ALL COMPONENTS AND ASSEMBLIES USED IN THIS FIRE

PROTECTION SYSTEM MUST BE SPECIFICALLY UL LISTED

OR FM APPROVED FOR THEIR INTENDED USE.

3. USE SCHEDULE 40 BLACK STEEL FIRE WATER PIPING

FOR PIPING 2 INCHES AND LESS. PIPING LARGER THAN

2 INCHES MUST BE MINIMUM SCHEDULE 10. PROVIDE

PIPING MATERIAL SUITABLE FOR USE IN POTABLE

WATER SYSTEMS IN COMPLIANCE WITH THE

INTERNATIONAL PLUMBING CODE AND LOCAL

JURISDICTION PRIOR TO THE BACKFLOW PREVENTER.

1. PROVIDE ALL NECESSARY COMPONENTS FOR A WET-PIPE

SYSTEM THROUGHOUT THE BUILDING. AT A MINIMUM

PROVIDE COMPONENTS AS INDICATED ON THESE

DRAWINGS. PROVIDE ADDITIONAL COMPONENTS AND

MODIFICATIONS AS REQUIRED TO PROVIDE A FULLY

FUNCTIONING FIRE SUPPRESSION SYSTEM.

2. COORDINATE ALL REQUIRED SYSTEMS TO THE

SATISFACTION OF THE ENGINEER AND AUTHORITY

HAVING JURISDICTION. CORRECT ANY DEFICIENCIES,

INCONSISTENCIES, OR POORLY COORDINATED

INSTALLATIONS AT NO ADDITIONAL COST.

3. FINAL DESIGN REQUIREMENTS (DEVICE QUANTITY, SIZE,

AND LOCATIONS) ARE THE SOLE RESPONSIBILITY OF THE

FIRE SUPPRESSION CONTRACTOR. DRAWINGS INDICATE

MINIMUM REQUIREMENTS; VERIFY AND COORDINATE

FINAL DESIGN REQUIREMENTS WITH THESE

CONSTRUCTION DOCUMENTS, SPECIFICATIONS,

REFERENCE DOCUMENTS, APPLICABLE CODES, AND

FACILITY USER REQUIREMENTS.

4. ALL DRAIN PENETRATIONS THROUGH EXTERIOR WALL

SHALL BE NO GREATER THAN 2'-0" ABOVE FINISHED

GRADE.

5. INSTALL FIRE PROTECTION PIPE HANGERS PER THE

FOLLOWING LIMITATIONS:

A. THE SINGLE POINT DEAD LOAD APPLIED TO ANY

STRUCTURAL MEMBER SHALL NOT EXCEED 300 LBS

[(WITH ADDITIONAL SAFETY FACTOR OF 250 LBS)].

PROVIDE TRAPEZE HANGERS TO DISTRIBUTE THE

LOAD BETWEEN STRUCTURAL MEMBERS WHERE A

SINGLE HANGER EXCEEDS THE LIMITATIONS.

B. SWAY BRACES FOR PIPING LATERAL LOADS SHALL

NOT BE ATTACHED TO ROOF JOIST BOTTOM

CHORDS. BRACE LOADS (WORKING STRESS) SHALL

BE LIMITED TO THE FOLLOWING:

1. 500 LBS. WHEN ATTACHED TO JOIST TOP

CHORD.

2. 500 LBS. WHEN ATTACHED TO FLOOR SLAB.

7. ALL VALVES INCLUDING CONTROL AND TRIM VALVES

SHALL BE WITHIN 6'-0" AFF UNO.

8. INSTALL ALL FIRE SUPPRESSION WATER PIPING AS PART

OF THIS PROJECT IN ACCORDANCE WITH NFPA 13

PROTECTION OF PIPING DAMAGE IN AREAS SUBJECT TO

EARTHQUAKES. SHORT PERIOD RESPONSE FACTOR Ss

0.55 PER STRUCTURAL SHEET S-001.

9. PROVIDE SPRINKLER GUARDS FOR SPRINKLERS IN THE

FOLLOWING AREAS:

A. TELECOM SPACES IN UNFINISHED AREAS.

B. AREAS THAT ARE LESS THAN 7 FT ABOVE FINISHED

FLOOR IN UNFINISHED AREAS.

C. AREAS SUBJECT TO MECHANICAL DAMAGE.

D. AREAS WHERE SPRINKLERS CAN BE GRABBED

FROM THE FLOOR LEVEL.

10. PROVIDE DRAINAGE TROUGHS BELOW SPRINKLER PIPES

IN TELECOM SPACES.

TYPE / FINISH

(EXPOSED)

QUICK RESPONSE

BRASS UPRIGHT

QUICK RESPONSE WHITE

RECESSED PENDENT

PLATE NUMBER WHERE DETAIL IS

DRAWN

DETAIL

NUMBER

DETAIL CALLOUT SYMBOL

SECTION CUT SYMBOL

SECTION

LETTER

PLATE NUMBER

WHERE SECTION IS

DRAWN

VIEW

SECTION

SECTION, DETAIL OR ELEVATION

IDENTIFICATION MARK

PLAN, SECTION, OR DETAIL TITLE

PLAN/SECTION/DETAIL TITLE

NO HATCH

DURATION

60 MIN

60 MIN

WET 2500 500 ORDINARY 1,20.30 100

EXTRA HAZARD

11.2STANDARD RESPONSE

BRASS UPRIGHT

N/A 90 MIN

UFC 3-600-01 9-7.3

UFC 3-600-01 9-7.3

NFPA 20 4.14.1.3

UFC 3-600-01 9-7.3

JOCKEY PUMP

FIRE PUMPF

J

ALTITUDE VALVE

SENSING LINE

FLEXIBLE PIPE JOINT

FLOW METER

JPC JOCKEY PUMP CONTROLLER

FPC FIRE PUMP CONTROLLER

LS LEVEL DETECTOR / SWITCH (PROVIDED BY DIVISION 21)

L

0' 125' 250' 500'

4-WAY BRACE

A2

FIRE PUMP SCHEDULE

PUMP

TYPE

FP-1

MARK

HSCP

DRIVE

TYPE

DIESEL

SERVICE

TYPE

FLOW

RATE

(GPM)

TOTAL

HEAD

(PSI)

FIRE PUMP

JOCKEY PUMP

500 65 60

JP-1 MSC ELECTRIC 5 70 1 1/2

HORSEPOWER

(HP)

ELECTRICAL DATA

V/Ph/Hz NOTES

208/3/60

- 1, 2

NOTE 1: ARRANGE FIRE PUMP AND JOCKEY PUMP TO AUTOMATICALLY START AND STOP IN ACCORDANCE

WITH NFPA 20.

NOTE 2: PROVIDE ENGINE BLOCK HEATER IN ACCORDANCE WITH UFC 3-600-01 AND CONTRACT SPECIFICATION 21 30 00. COORDINATE POWER WITH ELECTRICAL. SEE ELECTRICAL SHEETS EP402 AND EP701.

A2

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

P L O

T D

A T

E

F

IL

E P

A T

H

C

R e v it P ro je c ts

\1 F

C e n tr a l_ m rm a ff e i.

rv t

/1

/2

:3

:1

P

M

FX001

F

IR

E S

U P

P R

E S

S

IO

N N

O T

E S

L E

G E

N D

A N

D A

B B

R E

V

IA

T

IO

N S

S C

H O

F

IE

L D

B A

R R

A C

K S

H

A W

A

II

H O

N O

L U

L U

D

IS

T R

IC

T

F T

S

H A

F T

E R

H

A W

A

II

H O

'O H

U I'I

A

J V

A D

A H

L

M M

A F

F E

I

A M

O O

R E

/1

/2

A M

E N

D M

E N

T

F Y

M

C A

P N

C

H

IL

D D

E V

E L O

P M

E N

T C

E N

T E

R

B

IS

H

O P

S T

S

U

IT

E

H O

N O

L U

L U

H

A W

A

II

NTSSCALE:

D12

FLOW DIAGRAM

HYDRANT STATIC

HYDRANT FLOW

SCALE: 1:250

A

A M

-0

F

IR

E

P R

O T

E C

T

IO

N R

E V

IS

IO

N S

/2

/2

06/17/2022

DIESEL FUEL TANK

11217

FP1

2122 23 24 26

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

P L O

T D

A T

E

F

IL

E P

A T

H

C

R e v it P ro je c ts

\1 F

C e n tr a l_ a q u e v e d o b u rn s m c d .c o m

.r v t

/1

/2

:4

:2

A M

FX501

F

IR

E S

U P

P R

E S

S

IO

N D

E T

A

IL

S

S C

H O

F

IE

L D

B A

R R

A C

K S

H

A W

A

II

H O

N O

L U

L U

D

IS

T R

IC

T

F T

S

H A

F T

E R

H

A W

A

II

H O

'O H

U I'I

A

J V

A D

A H

L

M M

A F

F E

I

A M

O O

R E

/1

/2

A M

E N

D M

E N

T

F Y

M

C A

P N

C

H

IL

D D

E V

E L O

P M

E N

T C

E N

T E

R

B

IS

H

O P

S T

S

U

IT

E

H O

N O

L U

L U

H

A W

A

II

SCALE: 3/8" = 1'-0"

A11

FIRE PUMP ROOM FLOOR PLAN

NTSSCALE:

K1

FIRE PUMP ROOM - EAST ELEVATION

NTSSCALE:

A1

FIRE PUMP ROOM - 3D VIEW

0 2' 4' 6'

1. REFER TO FX001 FOR GENERAL NOTES, DESIGN CRITERIA,

ABBREVIATIONS AND SYMBOLS.

2. THIS MODEL HAS BEEN PREPARED AS A DIGITAL

REPRESENTATION OF THE PHYSICAL AND FUNCTIONAL

CHARACTERISTICS OF THE PROJECT FOR THE PURPOSES

OF CREATING RECORD DRAWINGS. THIS MODEL IS

PROVIDED FOR INFORMATIONAL PURPOSES ONLY AND

SHALL NOT BE USED AS A REPLACEMENT FOR, OR

ALTERNATIVE TO, RECORD DRAWINGS USED FOR

CONSTRUCTION.

1. 8" FLANGED LEAD-IN FROM FIRE WATER STORAGE TANK.

SEE CIVIL DRAWINGS FOR CONTINUATION.

2. 6" TO FIRE PUMP TEST HEADER

3. 4" RPZ BACKFLOW PREVENTER

4. 6" OS&Y GATE VALVE (TYP)

5. 500 GPM AT 65 PSI DIESEL FIRE PUMP

6. 6" CHECK VALVE

7. 6" TO WET PIPE SPRINKLERS

8. 6" TO FIRE DEPARTMENT CONNECTION

9. 4" OS&Y VALVE

10. 6" WET PIPE SYSTEM RISER

11. 6" RECIRCULATION LINE

12. 4" TO FIRE WATER STORAGE TANK

13. 4" ALTITUDE VALVE

14. 4" BUTTERFLY VALVE

15. 6" BUTTERFLY VALVE

16. 6" FLOW METER

17. 8" FROM UNDERGROUND FIRE WATER SUPPLY. SEE CIVIL

DRAWINGS FOR CONTINUATION.

18. PROVIDE HOUSEKEEPING PAD FOR DIESEL FUEL TANK.

COORDINATE WITH STRUCTURAL

19. PROVIDE HOUSEKEEPING PAD FOR FIRE PUMP.

COORDINATE WITH STRUCTURAL.

20. DIESEL PUMP EXHAUST PIPING

21. JOCKEY PUMP

22. DOUBLE WALL DIESEL FUEL TANK

23. FIRE PUMP CONTROLLER

24. JOCKEY PUMP CONTROLLER

25. PROVIDE 3'-0'' CLEAR SPACE IN FRONT OF FIRE PUMP AND

JOCKEY PUMP CONTROLLERS

26. PROVIDE 3'0'' CLEAR SPACE IN FRONT OF FIRE PUMP AND

JOCKEY PUMP

27. 6'' FIRE WATER TANK/FIRE PUMP BYPASS

GENERAL SHEET NOTES

SHEET KEYNOTES

1312 2

A

A M

-0

F

IR

E

P R

O T

E C

T

IO

N R

E V

IS

IO

N S

/2

/2

A2

A2

A2

FROM HEADER

DRAIN TO

EXTERIOR

TO WET

SYSTEMINSPECTOR'S

TEST

MAIN DRAIN

PRESSURE

RELIEF

VALVE

(SET AT

175 PSI)

F1

FPC

(S)

NC

TO PUMP TEST HEADER

& RECIRCULATION LINE

FROM FIRE WATER

STORAGE TANK TO FIRE

SPRINKLER

RISERS

J

JPC

FPC-1

JPC-1

NC

(S)

(S)

(S)

N C

(S

SPLASH BLOCK

MAIN DRAIN

EXTERIOR WALL

FIRE PUMP

TEST HEADER

(S)

FINISHED GRADE

FLANGED CONNECTION

IN BUILDING RISER

J

F

(S)

T O

S P

R

IN

K L E

R S

(S)

(S)

F

T

M A

X

F

T

M A

X

5 FT (MIN)

8" FROM UNDERGROUND FIRE

WATER SUPPLY. SEE CIVIL

DRAWINGS FOR CONTINUATION

H6

FX601

H1

FX601

ANTI-VORTEX PLATE

FIRE WATER TANK

OVERFLOW

4" TANK

FILL/RECIRCULATION

LINE 2

BY DIVISION 33 BY DIVISION 21

SENSING LINE

(S)(S)

(S) (NC)

8" SUPPLY FROM FIREWATER

STORAGE TANK. SEE CIVIL

DRAWINGS FOR CONTINUATION

LS

L

BY DIVISION 21

(S)

(S)4

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

P L O

T D

A T

E

F

IL

E P

A T

H

C

R e v it P ro je c ts

\1 F

C e n tr a l_ a q u e v e d o b u rn s m c d .c o m

.r v t

/1

/2

:4

:2

A M

FX601

F

IR

E S

U P

P R

E S

S

IO

N R

IS

E

R D

IA

G

R A

M

S C

H O

F

IE

L D

B A

R R

A C

K S

H

A W

A

II

H O

N O

L U

L U

D

IS

T R

IC

T

F T

S

H A

F T

E R

H

A W

A

II

H O

'O H

U I'I

A

J V

A D

A H

L

M M

A F

F E

I

A M

O O

R E

/1

/2

A M

E N

D M

E N

T

F Y

M

C A

P N

C

H

IL

D D

E V

E L O

P M

E N

T C

E N

T E

R

B

IS

H

O P

S T

S

U

IT

E

H O

N O

L U

L U

H

A W

A

II

NTSSCALE:

H1

WET RISER DETAIL

NTSSCALE:

H6

FIRE PUMP DETAIL

NTSSCALE:

A1

FIRE SUPPRESSION RISER DIAGRAM

1. REFER TO FX001 FOR GENERAL NOTES, DESIGN CRITERIA,

ABBREVIATIONS AND SYMBOLS.

2. COORDINATE PIPE HANGERS, SUPPORTS, AND SEISMIC

BRACING WITH STRUCTURAL.

1. PROVIDE AUTOMATIC AIR VENTS AT HIGH POINTS IN THE

SYSTEM TO VENT AT LEAST 95% OF THE VOLUMETRIC

CAPACITY OF THE SYSTEM. DESIGN THE SPRINKLER

SYSTEM TO REDUCE THE QUANTITY OF AUTOMATIC AIR

VENTS SUCH AS CONNECTING BRANCHLINES OR

PROVIDING A CROSS-MAIN AT THE PEAK.

2. EXTERIOR VALVES SHALL BE MECHANICALLY SUPERVISED.

3. CONCRETE FIRE WATER STORAGE TANK BY STRUCTURAL.

SEE STRUCTURAL DRAWINGS.

4. 6" FIRE WATER TANK/FIRE PUMP BYPASS

GENERAL SHEET NOTES

SHEET KEYNOTES

A

A M

-0

F

IR

E

P R

O T

E C

T

IO

N R

E V

IS

IO

N S

/2

/2

BFP

SEE CIVIL

DRAWINGS FOR GW

& SS CONTINUATION

SEE CIVIL DRAWINGS

FOR DCW CONTINUATION

DB

P-103

A3

P-108

A3

P-104

A2

P-109

A3

P-105

A3

P-110

A5

P-111

A7

P-106

A6

P-112

A7

P-107

A6

A F

EC

A2

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

KEY PLAN

A B C

D

E

P L O

T D

A T

E

F

IL

E P

A T

H

C

R e v it P ro je c ts

\1 M

C e n tr a l_ b fo n s e c a b u rn s m c d .c o m

.r v t

/1

/2

:3

:2

A

M

P-101

O V

E R

A L L P

L U

M B

IN

G

P L A

N

S C

H O

F

IE

L D

B A

R R

A C

K S

H

A W

A

II

H O

N O

L U

L U

D

IS

T R

IC

T

F T

S

H A

F T

E R

H

A W

A

II

H O

'O H

U I'I

A

J V

B .F

O N

S E

C A

T .S

A B

IN

A

S

D .G

R A

M E

R

/1

/2

D E

S

IG

N C

O M

P L E

T E

S U

B M

IT

T

A L

F Y

M

C A

P N

C

H

IL

D D

E V

E L O

P M

E N

T C

E N

T E

R

B

IS

H

O P

S T

S

U

IT

E

H O

N O

L U

L U

H A

W A

II

1/16" = 1'-0"A1

OVERALL PLUMBING PLAN

0 8' 16' 32'

PLAN NORTH

GENERAL NOTES:

FOR PLUMBING LEGENDS, NOTES AND ABBREVIATIONS,

SEE SHEET P-001.

1.

1 DOMESTIC WATER PIPE SIZES ARE BASED ON A MINIMUM

WORKING PRESSURE OF 59 PSI AT A FLOW RATE OF 250

GPM AT THE LOCATION WHERE THE MAIN SERVICE ENTERS

THE BUILDING.

KEYED NOTES:

A

A M

-0

E

E S

-1 R

E L O

C A

T

IO

N I

N F

IR

E

P U

M P

R O

O M

/2

/2

6.17.22

P-408

A5

P-406

A3

121A

TP-13 TP-12

118A

1 1/4" DHW

2" DCW

M A

T C

H L

IN

E

A

P -1

P-403

A1

1 1/4" DCW

1" DHW

SEE CIVIL FOR DOMESTIC

WATER CONTINUATION

4" DCW

121B

124B

122 119

118B

121 1

A9

P-303

A1

P-303

F

GI-1

WC-1

LAV-1

WC-3

WC-2

HS-1

EWC-1

LAV-5

LAV-6

HS-2

HS-2

SB-1

1/2" CIRCUIT SETTER

SET TO 0.3 GPM

SERVING CP-1

1/2" CIRCUIT SETTER

SET TO 0.45 GPM

SERVING CP-1

1/2" CIRCUIT SETTER

SET TO 0.3 GPM

SERVING CP-1

1/2" CIRCUIT SETTER

SET TO 0.5 GPM

SERVING CP-1

1/2" DHWR

3/4" DCW

4 4

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

KEY PLAN

A B C

D

E

P L O

T D

A T

E

F

IL

E P

A T

H

C

R e v it P ro je c ts

\1 M

C e n tr a l_ b fo n s e c a b u rn s m c d .c o m

.r v t

/1

/2

:3

:2

A

M

P-105

P L U

M B

IN

G

P L A

N

D O

M E

S T

IC

W

A T

E R

A

R E

A C

S C

H O

F

IE

L D

B A

R R

A C

K S

H

A W

A

II

H O

N O

L U

L U

D

IS

T R

IC

T

F T

S

H A

F T

E R

H

A W

A

II

H O

'O H

U I'I

A

J V

B .F

O N

S E

C A

T .S

A B

IN

A

S

D .G

R A

M E

R

/1

/2

D E

S

IG

N C

O M

P L E

T E

S U

B M

IT

T

A L

F Y

M

C A

P N

C

H

IL

D D

E V

E L O

P M

E N

T C

E N

T E

R

B

IS

H

O P

S T

S

U

IT

E

H O

N O

L U

L U

H A

W A

II

1/8" = 1'-0"A3

PLUMBING PLAN - DOMESTIC WATER - AREA C

KEYED NOTES:

ROOM SCHEDULE - AREA C

NO. ROOM NAME

122 TOILET

123 EXT. STORAGE

124B STORAGE

180 HALLWAY

ROOM SCHEDULE - AREA C

NO. ROOM NAME

118A TOILET

118B STORAGE

119 CENTRAL STORAGE 2

120 EXT. STORAGE

121 PRESCHOOL/PRE-K/KINDERGARTEN ACTIVITY ROOM

121A TOILET

121B STORAGE

ROOM SCHEDULE - AREA C

NO. ROOM NAME

113 KITCHEN

113A DRY FOOD STORAGE

114 LAUNDRY ROOM

115 ELECTRICAL ROOM 2

116 CCTV EQUIPMENT ROOM

117 MECHANICAL

118 OUTREACH/TRANSITIONAL CARE ACTIVITY ROOM

8'4' 16'0

PLAN NORTH

1 FOR TRAP PRIMER DETAIL, SEE H14/P-502 OR E1/P-501.

PROVIDE ACCESS PANEL ON WALL AT TP LOCATION.

INSTALL PER MANU. REQUIREMENTS. REFER TO TRAP

PRIMER SCHEDULE ON P-601 FOR DRAINS SERVED.

2 FOR GREASE INTERCEPTOR DETAIL, SEE A1/P-505.

3 DCW & DHW BRANCH ISOLATION BALL VALVE SIZE PER

PIPE.

4 DHW, DHWR, DCW BRANCH PIPING FROM CORRIDOR TO

ROOMS DROP TO 9'3" BOP EL.

GENERAL NOTES:

1. FOR PLUMBING LEGENDS, NOTES AND ABBREVIATIONS,

SEE SHEET-P-001.

2. PIPE SIZES TO INDIVIDUAL FIXTURES ARE SHOWN ON

THE RISER DIAGRAMS

3. FOR TRAPEZE PIPE SUPPORT DETAIL, SEE K7/P-503.

4. FOR CLEVIS HANGER DETAIL, SEE J16/P-503.

A

A M

-0

E

E S

-1 R

E L O

C A

T

IO

N I

N F

IR

E

P U

M P

R O

O M

/2

/2

A1

P-301

A13

P-301

WH-1

EWH-3

EWH-2

EWH-1

1" DHWR

140°F

2 1/2" DHW

120°F

4" DCW

HB-1

CP-1

TMV-1

BP-01

4" DCW

ET-01

CP-2

2 1/2" DHW

140°F

PUMP ISOLATION

VALVES

PUMP BY-PASS

VALVE (N.C.)

BFP-1

MECHANICAL

TP-11

4" DCW

10' - 1" BOP EL

P-504

A10

4" DCW

8' - 6" BOP EL

1 1/4" DCW

10' - 3" BOP EL

EES-1

M-2

EES-1

2" DCW

10' - 2" BOP EL

3/4" DCW UP/DN

CHILLED WATER MAKEUP

CONNECTION SET AT 2'-0" AFF

1" DCW3/4" DCW

1 1/4" DCW 1 1/4" DCW

1 1/4" DCW 3/4" DCW

TO BFP-1

COORDINATE

LOCATION OF EES-1

WITH FIRE AND

ELECTRICAL

CONTRACTOR

A2

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

P L O

T D

A T

E

F

IL

E P

A T

H

C

R e v it P ro je c ts

\1 M

C e n tr a l_ b fo n s e c a b u rn s m c d .c o m

.r v t

/1

/2

:3

:2

A

M

P-406

E N

L A

R G

E D

P L U

M B

IN

G

P L A

N S

S C

H O

F

IE

L D

B A

R R

A C

K S

H

A W

A

II

H O

N O

L U

L U

D

IS

T R

IC

T

F T

S

H A

F T

E R

H

A W

A

II

H O

'O H

U I'I

A

J V

B .F

O N

S E

C A

T .S

A B

IN

A

S

D .G

R A

M E

R

/1

/2

D E

S

IG

N C

O M

P L E

T E

S U

B M

IT

T

A L

F Y

M

C A

P N

C

H

IL

D D

E V

E L O

P M

E N

T C

E N

T E

R

B

IS

H

O P

S T

S

U

IT

E

H O

N O

L U

L U

H A

W A

II

1/4" = 1'-0"A3

ENLARGED PLUMBING PLAN - DOMESTIC WATER - MECH. ROOM

PLAN NORTH

0 2' 4' 8'

1 PROVIDE HYDROSTATIC SEAL. FOR DETAIL, SEE A1/P-503.

2 FOR DOMESTIC WATER BOOSTER PUMP DETAIL, SEE

A11/P-501.

3 FOR DOMESTIC WATER CIRCULATION PUMP DETAIL, SEE

A1/P-502.

4 FOR DOMESTIC WATER SERVICE ENTRANCE - 3" & LARGER

DETAIL, SEE A1/P-501.

5 DHW, DHWR, DCW MAIN PIPING IN CORRIDOR AT 10'2" BOP

EL.

6 DHW, DHWR, DCW BRANCH PIPING FROM CORRIDOR TO

ROOMS DROP TO 9'3" BOP EL.

7 FOR PIPE PENETRATIONS DETAIL, SEE A7/P-503.

8 PROVIDE DIAPHRAGM OR BUFFER TANK FOR BOOSTER

PUMP SIZED AND INSTALLED BY CONTRACTOR PER

MANUFACTUTER'S RECOMMENDATIONS.

9 PROVIDE ADVANCED WATER METER, M-1. SEE ADVANCED

METER SCHEDULE/P-602 AND DETAIL A10/P-504 FOR

REQUIREMENTS.

10 FOR MAKE-UP WATER DETAIL, SEE HVAC DETAIL G12/M-503.

11 FOR DOMESTIC WATER HEATING SYSTEM DIAGRAM, SEE

A1/P-502.

KEYED NOTES:

GENERAL NOTES:

1. FOR PLUMBING LEGENDS, NOTES AND ABBREVIATIONS,

SEE SHEET-P-001.

2. PIPE SIZES TO INDIVIDUAL FIXTURES ARE SHOWN ON

THE RISER DIAGRAMS

3. FOR TRAPEZE PIPE SUPPORT DETAIL, SEE K7/P-503.

4. FOR CLEVIS HANGER DETAIL, SEE J16/P-503.

A

A M

-0

E

E S

-1 R

E L O

C A

T

IO

N I

N F

IR

E

P U

M P

R O

O M

/2

/2

M

M

M

MMM

M M

M

MM

M M

M

M

M

M

M

M

J J

M

J

J J

J

M

M

J

J

MM

J J J

M

J M

M

2P1-33

TR

2P1-33

TR

2P1-33

TR

2P1-31

TR

CHP-2

4P1-13,15,17

HRP-1

4P1-7,9,11

BF-1

2P1-16

BF-2

2P1-18

BF-3

2P1-20

DOAS-1

4P1-19,21,23

AHU-1

4P1-25,27,29

EWH-1

2P1-2,4

EWH-2

2P1-6,8

EWH-3

2P1-10,12

CP-1

2P1-14

CP-2

2P1-14

BP-2

4P1-31,33,35

2P1-37

TR WPIU GFI

FA1-8

TR

CU-REF

2P3-40,42

CU-116

2P1-43,45

EF-117

2P1-22

CU-127

2P1-47,49

E3C 2P3-7,9,11

E3A 2P3-1,3,5

FUSED

D200/F110

FUSED

D100/F45

2P1-31

TR

STEEL CHANNEL

SUPPORT (TYP)

2P1-37

TR GFI WPIU

1 (TYP)

FUSED

D400/F300

2P1-37

TR GFI WPIU

JP-1

FA1-1,3,5

D100

D100

FIRE PUMP RM

FAC

FA1-4

NAC

FA1-4

AMP

FA1-4

F

AHU-2

4P1-1,3,5

FUSED

D30/F15

CH-1

MDP-1-1

CHP-1

4P1-8,10,12

HRP-2

4P1-14,16,18

FUSED

D30/F15

FUSED

D100/F70

TP-11

2P1-44

AHU-1

2P1-51

DOAS-1

DOAS-1

4P1-2,4,6

DOAS-1

4P1-20,22,24

FUSED

D30/F15

FUSED

D30/F15

FUSED

D30/F15

JPC

FA1-2

BLOCK HEATER

FA1-11

FIRE PUMP BATTERY CHARGER

FA1-9

FPC

FA1-7

ESS-1

2P1-46

D30

D100

M

M M

M

M MM

DDC CONTROLLER

2P1-48

2P1-31

TR

A13

EP402

FUSED

D30/F15

FUSED

D30/F20

FUSED

D30/F20

FUSED

D30/F15

FUSED

D30/F15

ESS-1

2P1-46

M

FA1-8

TR

TP2

TP2-5

TR

FCU-116

TP2-7,9

L5-30 RECPTACLE, MOUNT TO

BOTTOM OF CABLE TRAY

NEC DATA RACK

TP2-1

TP2-3

S

4" CONDUITS TO

TMH-2 AND PB-2B

110 BLOCK

4" CONDUITS TO

COMMUNICATIONS

ROOM 127

TP2-5

TR

TP2-5

TR

PET

TP2-5

TR

TP2-5

TR

TP2-5

TR

3/4" PLYWOOD

BACKBOARD

(TYP)

PBB

TP2-5

TR CATV 54" AFF

D30

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

C

R e v it P ro je c ts

\1 E

C e n tr a l_ m s a h a ra

.r v t

/1

/2

:3

:5

A

M

EP402

P O

W E

R E

N L A

R G

E D

P L A

N S

S C

H O

F

IE

L D

B A

R R

A C

K S

H

A W

A

II

H O

N O

L U

L U

D

IS

T R

IC

T

F T

S

H A

F T

E R

H

A W

A

II

H O

'O H

U I'I

A

J V

M S

A H

A R

A

A Q

U E

V E

D O

K S

H O

R T

/1

/2

D E

S

IG

N C

O M

P L E

T E

S U

B M

IT

T

A L

F Y

M

C A

P N

C

H

IL

D D

E V

E L O

P M

E N

T C

E N

T E

R

B

IS

H

O P

S T

S

U

IT

E

H O

N O

L U

L U

H

A W

A

II

SCALE: 1/4" = 1'-0"A5

POWER MECHANICAL 117

PLAN NORTH

0 2' 4' 8'

GENERAL NOTES:

1. REFER DRAWINGS E-001 AND E-002 FOR GENERAL NOTES, LEGEND, AND

ABBREVIATIONS.

2. REFER DRAWING ES101, FOR SITE PLAN NEW WORK.

3. ALL EXTERIOR DISCONNECTS, AND ELECTRICAL EQUIPMENT

ENCLOSURES SHALL BE RATED NEMA 4X.

4. COORDINATE FINAL FUSE SIZE FOR ALL 480V EQUIPMENT WITH ACTUAL

MECHANICAL EQUIPMENT.

5. COORDINATE FINAL DISCONNECT LOCATION WITH ACUTAL MECHANICAL

EQUIPMENT INSTALLATION, AND PROVIDE PROPER NEC CLEARANCE.

PROVIDE STEEL CHANNEL SUPPORTS TO SUPPORT ALL DISCONNECT

SWITCHES.

KEYED NOTES:

PROVIDE STEEL CHANNEL SUPPORT FOR DISCONNECT AND

RECEPTACLE.

PROVIDE 1" CONDUIT FROM CONDENSING UNIT TO FREEZER

COIL CONNECTION IN KITCHEN. REFERENCE AND COORDINATE

WITH SHEET IF102.

COORDINATE LOCATION OF DISCONNECTS WITH MECHANICAL

DUCTWORK.

PROVIDE MATCHING NAMEPLATES TO EACH BOOSTER FAN AND

EACH RESPECTIVE DISCONNECT.

WEATHERPROOF IN USE ENCLOSURE SHALL BE LOCKABLE

WITH TAMPER RESISTANT GFI…