PN70551_100_DWG_Part11.pdf
PDF 7 MB Posted
- Attached to
- FY22 Military Construction Army (MCA) 070551 Child Development Center, Schofield Barracks, Oahu, Hawaii
- Solicitation number
- W9128A22R0020
About this file
This announcement is for a solicitation seeking design-build construction services for a Child Development Center at Schofield Barracks in Hawaii. The project scope includes a 37,300 square foot building, 38,311 square feet of playground area, 146 parking spaces, demolition of five buildings totaling 25,155 square feet, and site development. Evaluation factors are experience, past performance, technical approach, and price using LPTA procedures. The period of performance is 1,237 calendar days from notice to proceed, and the project magnitude is $25-50 million. The NAICS code is 236220 with a small business size standard of $39.5 million. The Army Corps of Engineers intends to issue an unrestricted RFP and award a firm fixed-price contract.
View the file
Other files
Show all 33
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
28'
28 '
28'
E
E
KA
IO
NA
AV
EN
UE
ULRI
CH WAY
ULRICH WAY
KUAIKUA STREET
IK
E
LE
A STR
E E T
TEL
D12
D15
D
D12
D12
28'
28 '
28'
116,657.44 N
619,239.88 E
900.67
W
W
W
W 4 W
W
E
LY
KA
IO
NA
AV
EN
UE
ULRI
CH WAY
ULRICH WAY
KUAIKUA STREET
IK
E
LE
A
S T R E E T
IK
E
LE
A STR
E E T
TEL
D12
D15
D
W6
W 12 W
W
W
W
W 12W
W
W
W
W
W
W
W
W6 W6
W6
W6
W6
W6
W
W
W6 W6
W6
W6
W8
W
W
W drainage basin co co fh fh fh fh tel d18 d12 d15 d8 d12 roof linecm u wall
BID OPTION B
SWALE CL STA. 5+33.52
896.63(E)
893.99
18.50'
18.50'
73'
9'
100'
9'
30"
30"
50'
W12
S6
S8
C1
ES501
H9
ES301
A2
ES301
A9
ES301
H2
ES302
H9
ES302
A2
ES302
G1
ES304
A9
ES303
H2
ES301
E15
ES501
G1
ES401
H9
ES303
H1
ES303
G9
ES304
A1
ES304
A9
ES304
H1
ES305
H8
ES305
A1
ES305
A8
ES305
H1
ES306
K1
ES504
J3
ES505
1'
- 0
1' - 6"
2' MIN.
TRENCH WIDTH
BA
SE
C
OU
RS
E
3'
- 0
1'
- 0
6"
TRENCH WIDTH
" M
IN
REPAVEMENT WIDTH
3'
G11
ES401
6'- 0"
6" 5'-0" 6"
6"
6'-0"
B9
ES501L9
ES501
6' - 5" 6' - 5"
6'
- 1
0" O
VE
RA
LL
6'
- 0
" I
NS
ID
E
CL
EA
R
3'
- 5
3'
- 5
12' - 10" OVERALL
12' - 0" INSIDE CLEAR
6' - 0" 6' - 0"
6" 6" 6" 1' - 1"
1'
- 1
6"
1'
- 1
6"
2' - 6" 6"
8'
- 0
7'
- 0
" I
NS
ID
E
CL
EA
R
7" 1'
- 1 0 1
/2" 1'
- 1 0 1
/2" 1'
- 1 0 1
/2" 9 1
/2"
0"
6" 6"
1'
- 0
2'
- 2
/2
8"
6" 6"
6" 6"
8" 2'
- 5
/2
4'
- 4
/2
3'
- 7
/2
9" 6" 8'
- 0
1'
- 1
0 1 /2"
1'
- 1
0 1 /2"
1'
- 1
0 1 /2"
9 1 /2"
0"
6" 6"
1'
- 0
2'
- 2
/2
6"
6" 6"
6" 2'
- 5
/2
7"
7'
- 0
4'
- 4
/2
3'
- 7
/2
1'
- 4
1/ 2"
8" 8"
6'
- 1
0" O
VE
RA
LL
12' - 10" OVERALL
6" 8 S
PA
CE
S
8" C
.C
6" 3"
3" 6" 9 SPACES @ 5" C.C.
9" 1'
- 5
3 S
PA
CE
S
" C .C
1'
- 5
7 5 /8"
3' - 10" 9 SPACES @ 5" C.C.
1' - 0" 13 SPACES @ 10" C.C. 1' - 0"
4'
- 4
1/ 8"
O
VE
RA
LL
3/4
3'
- 9
3/ 8"
6" 3/4
5 1/2"
5"
3/4"
4'
- 4
1/ 8"
O
VE
RA
LL
3/4
3'
- 9
3/ 8"
6"
7 7/16"
5"
3/4"
3/4
3/4
1' - 0"
1'
- 0
1' - 0"
1'
- 0
1'
- 0
8" 4"
6' - 0 1/8" 6"
6"
4'
- 4
3/ 4"
6"
6"
1' - 6"
1' - 3"
1/
2" 6"
4"
6"
4'
- 4
3/ 4"
6"
6"
6' - 0 1/8"
6" 1' - 7 11/32" 1' - 9 7/16" 1' - 7 11/32" 6"
5' - 0 1/8"
3'
- 4
3/ 4"
1'
- 8
3/ 8"
4" 4"
6"
VA
RI
ES
6' - 0 1/8"
6" 6"
VARIES VARIES
9"
2'
- 4
/2
6" 6"
2" 2"
12" 12"
5' - 11 3/16"
3 1/2" 5' - 4 3/16" 3 1/2"
1 13/16" 1 3/4"
9 1/2" 7 1/2" 7 1/2" 7 1/2" 7 1/2" 7 1/2" 7 1/2" 9 11/16" 4"
4" 3 1
/2"
1 3/4" 1 13/16"
3 1/2"
2'
- 1
1'
- 6
9" 9"
3 1 /2"
3 1 /2"
1 1 3/1
6" 1 3
/4" 1 3
/4" 1 1
3/1 6"
6"
6"
1'
- 9
7/
4" 4"
5' - 7 5/8" 1' - 10 1/2" 1' - 10 11/16" 1' - 10 1/2"
8" 8" 8" 8" 8" 8"
8" 8"
1' - 10 1/2"
8" 8"
1' - 10 1/2" 1/16"
8" 8"
1' - 10 1/2" 1/16"
E11
ES505
5' - 7 9/16"
E15
ES505
1/4
1/4"
1/4"
1/4 "1/4"
1/4
1'
- 0
3 1/2"
2"
1/ 2"
5/ 8"
9 9/16" 7 1/2" 7 1/2" 7 1/2" 7 1/2" 7 1/2" 7 1/2" 9 9/16"
2" 2"
6" 6"
2 3 /16
3 1/2" 5' - 4 3/16" 3 1/2"
1 11/16" 1 3/4"
3/32"
1 25/32"
3/32"
1 11/16" 1 7/8"
3/32"
1/ 4"
1" 2 1
/2" 1/
4" 1/
4" 1"
2 1 /2"
1 1 /4"
1 23/32" 1 25/32" 1 23/32"
3/32"
2"
3 1/2" 1' - 6" 3 1/2" 2' - 1"
9" 9" 1 21/36"
1 27/32"
6" 8"
1 27/32" 1 21/32"
1 7/8"1 11/16"1' - 5 7/8"1 11/16"1 7/8" 3 1
/2"
F1
EG501
H14
EG501
A7
EG501
J2
EG502
J10
EG502
H14
EG501
B1
EL506
E1
EL503
G2
EL505
G2
EL505
G2
EL505
E1
EL503
E1
EL503
C12
EL504
B1
EL506
H2
EL504
E11
B1
EL506
1"
6"
2'- 0"
H10
EP401
C16
EP401
C3
EP401
A12
EP501
B7
EP402
C10
EP401
C3
EP401
H1
J2
EG502
H1
EP501
3'
4'
- 8
3/ 8"
1' - 8" 1' - 5" 5"
3' - 4"
3' - 8 3/8"
4"
3' - 1"
4' - 9"1 1/2"
4"7 1/2" 4" 6 5/16" 1'
- 5
5' - 0"
5'
- 6
1' - 6" 2' - 1 1/2" 1' - 4" 5' - 3"
5' - 8"
3' - 1 3/4"
4 5 /16
2'
- 6 " 4 1/2"
1' - 10 1/4"
4'
- 9
3'
- 2
8"
5' - 0"
3' - 1 3/4"
4 5 /16
1'
- 9 " 4 1/2"
1' - 10 1/4"
3'
- 1
1"
2'
- 2
6"
5' - 5"1 1/2"
1'
- 5
2"
4' - 4"
8" 8" 1' - 1 1/2" 8" 8"
5' - 7"
2'
- 6
6' - 0"
1' - 8" 1' - 8"
4'
- 8
3/ 4"
T-401
J8 T-401
A12
T-402
J8 T-402
3' - 0"
2'
- 0
3'
- 0
3' - 0"
7'
- 0
" A1
TY502
H1
TY501
A1
TY501
A12
TY501
A7
TY501
A1
TY501
A1
TY501
4'
3' 0"
M
AX
3'-0" MAX
8' -0
'-0
THE ENTIRE INSTALLATION SHALL COMPLY WITH ALL APPLICABLE REQUIREMENTS
OF USACE CRITERIA, INTERNATIONAL BUILDING CODE, INTERNATIONAL
PLUMBING CODE, UNIFORM FIRE CODE, NATIONAL ELECTRICAL CODE, ASHREA
STANDARDS, ASME PRESSURE PIPING CODE, NFPA, NSF INTERNATIONAL AND ALL
OTHER ANGENCIES HAVING JURISDICTION.
THE DRAWING AND SPECIFICATIONS ARE INTENDED TO COVER THE COMPLETE
INSTALLATION OF SYSTEMS TO FUNCTION AS DESCRIBED AND SPECIFIED. THE
OMISSION OF REFERENCE TO ANY NECESSARY SHALL NOT RELIEVE THE
CONTRACTOR FROM PROVIDING SUCH LABOR AND MATERIAL.
1. COORDINATE AND PROVIDE PROPER ACCESS FOR EQUIPMENT DELIVERY AND
INSTALLTION. FOR EXAMPLE: COORDINATING CONSTRUCTION OF WALL SECTIONS
OR DOOR OPENINGS, ETC.
2. ALL DIMENSIONS SHOWN ON THIS PLAN ARE INDICATED TO BE TAKEN FROM
FINISHED SURFACES AND INCLUDE ANY TILE, FURRING, ETC. CONTRACTOR SHALL
MAKE ALLOWANCES SUCH THAT WHEN FINISHED MATERIAL IS APPLIED TO VERTICAL
AND HORIZONTAL SURFACES, THE FINAL DIMENSIONS CONFROM TO THIS PLAN.
3. FURNISH AND INSTALL CHANNEL FRAMING OR " Z " BAR IN POSITION AS SHOWN ON
THE BUILDING WORK PLAN FOR INSTALLATION OF HOOD HANGERS. REFER TO THE
STRUCTURAL ENGINEER'S DRAWINGS FOR EXACT REQUIREMENTS FOR SUPPORT
FRAMING. COORDINATE LOCATIONS WITH K.E.C.
4. ALL WALLS IN CONTACT WITH OR WITHIN 6 INCHES OF RANGES, OVENS, STEAMER,
KETTLES, BRAISING PAN SHALL BE CONSTRUCTED OF NON-COMBUSTIBLE HEAT-
PROOF MATERIALS.
6. PROVIDE LEVEL FLOOR BELOW KITCHEN EQUIPMENT THEN SLOPE TO FLOOR
DRAINS AS REQUIRED.
GENERAL CONTRACTOR (G.C.) NOTES:
7. ALL BUILDING WORK "QF" DRAWINGS ARE INDICATED FOR REFERENCE
AND CONVENIENCE OF THE ARCHITECT, ENGINEERS, CONTRACTOR
AND/OR SUB-CONTRACTORS. REFER TO THE CORRESPONDING
RELATED SECTONS FOR EXACT REQUIREMENTS.
5. PROVIDE WALL REINFORCEMENT OR BACKING PLATES AS REQUIRED FOR
INSTALLATION AND TO SUPPORT WALL MOUNTED EQUIPMENT. COORDINATE
LOCATIONS AND REQUIREMENTS WITH K.E.C.
ELECTRICAL NOTES:
THE ENTIRE INSTALLATION SHALL COMPLY WITH ALL APPLICABLE
REQUIREMENTS OF USACE CRITERIA, INTERNATIONAL
BUILDING CODE, NATIONAL ELECTRIC CODE, NFPA, NSF INT., UL,
ASHRAE STANDARDS, ASTME INTERNATIONAL AND ALL OTHER
AGENCIES HAVING JURISDICTION.
THE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO COVER
THE COMPLETE INSTALLTION OF SYSTEMS TO FUNCTION AS
DESCRIBED AND SPECIFIED. THE OMISSION OF REFERENCE TO
ANY NECESSARY WORK SHALL NOT RELIEVE THE CONTRACTOR FROM
PROVIDING SUCH LABOR AND MATERIAL.
1. ALL EQUIPMENT AND RECEPTACLES ARE TO BE FULLY CONNECTED.
PROVIDE FINAL CONNECTIONS AND FURNISH ALL TOOLS, MATERIALS
AND ACCESSORIES AS REQUIRED WHETHER INDICATED OR NOT FOR
A COMPLETE INSTALLATION.
2. FURNISH AND INSTALL HOOD LIGHT FIXTURES, WITH LAMPS WIRED
COMPLETE WITHIN HOOD TO ONE JUNCTION BOX AND PROVIDE FINAL
CONNECTION.
3. PROVIDE ALL CONDUITS, JUNCTION BOXES, CONVENIENCE OUTLETS
(MOUNTED HORIZONTALLY), SWITCHES, STAINLESS STEEL COVER
PLATES AND PULL BOXES NOT BUILT INTO EQUIPMENT OR FABRICATED
FIXTURES.
A. ALL ROUGH-INS SHALL BE CONCEALED WHEREVER POSSIBLE.
B. ADDITIONAL CONDUIT AND CONTROL WIRING FOR TELEPHONES,
COMPUTERS, POS UNIT REQUIREMENTS, AND CASH REGISTERS
SHALL BE LOCATED BY THE ELECTRICAL ENGINEER.
C. FLEX CONNECTIONS SHALL BE MOUNTED TO UNDERSIDE OF
EQUIPMENT WHERE APPLICABLE.
4. PROVIDE LOCKING HASPS AT BREAKER PANELS IN LIEU OF DISCONNECT
SWITCHES FOR DISHWASHER, BOOSTER HEATER AND /OR EQUIPMENT
REQUIRING DISCONNECTS. REFER TO ELECTRICAL DRAWINGS.
5. FURNISH AND INSTALL ALL INTERCONNECTING CONDUITS, CONTROL
WIRING, MICRO SWITCHES AND/OR CONTACTORS BETWEEN THE
HOOD AND FIRE SUPPRESSION SYSTEM.
6. CONDUIT ROUGHING-IN SHALL BE STUBBED IN WALLS, NO EXCEPTIONS.
7. ELECTRICAL REQUIREMENTS ARE INDICATED FOR INDIVIDUAL
EQUIPMENT ITEMS. COMBINING OF LINES FOR SIMPLIFICATION IS
ACCEPTABLE.
M
8. ALL ELECTRICAL "QF" DRAWINGS ARE INDICATED FOR REFERENCE AND
CONVENIENCE OF THE ARCHITECT, ENGINEERS, CONTRACTOR AND/OR
SUB-CONTRACTORS. REFER TO THE CORRESPONDING RELATED
SECTONS FOR EXACT REQUIREMENTS.
MECHANICAL & PLUMBING NOTES:
THE ENTIRE INSTALLATION SHALL COMPLY WITH ALL APPLICABLE
REQUIREMENTS OF USACE CRITERIA, INTERNATIONAL
BUILDING CODE, INTERNATIONAL PLUMBING CODE, NFPA, NSF INT.,
ASHRAE STANDARDS, ASME INTERNATIONAL AND ALL OTHER
AGENCIES HAVING JURISDICTION.
THE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO COVER
THE COMPLETE INSTALLATION OF SYSTEMS TO FUNCTION AS
DESCRIBED AND SPECIFIED. THE OMISSION OF REFERENCE TO
AND NECESSARY WORK SHALL NOT RELIEVE THE CONTRACTOR FROM
PROVIDING SUCH LABOR AND MATERIAL.
1. PROVIDE FINAL CONNECTIONS AND ALL TOOLS, MATERIALS AND
ACCESSORIES AS REQUIRED WHETHER INDICATED OR NOT FOR
COMPLETE INSTALLATION.
A. FINAL CONNECTION TO EQUIPMENT SHALL BE A FLEX
CONNECTION, NOT SOFT COPPER. SEE MECH. DWGS.
B. FLEX CONNECTIONS SHALL BE CONCEALED AND MOUNTED
TO UNDERSIDE OF EQUIPMENT WHERE APPLICABLE.
C. INTERCONNECTING PIPING SHALL BE HARD/RIGID COPPER.
2. FURNISH AND INSTALL ALL REQUIRED TRAPS AND SHUT-OFF
VALVES. SHUT-OFF VALVES SHALL BE ACCESSIBLE.
3. GREASE TRAPS ARE TO BE PROVIDED WHERE REQUIRED AND
SHALL BE LOCATED BELOW OR SET FLUSH WITH FLOOR. REFER
TO MECHANICAL DRAWINGS FOR LOCATION AND REQUIREMENTS.
4. FURNISH AND INSTALL STOPS ON ALL HOT AND COLD WATER
LINES AT EQUIPMENT IN AN ACCESSIBLE POSITION.
5. GENERAL WATER PRESSURE IN KITCHEN AREA: 60 P.S.I. - REFER
TO MECHANICAL SECTION. EQUIPMENT REQUIRING DIFFERENT
6. FURNISH AND INSTALL PROPERLY SIZED INDIRECT WASTE LINES
FOR STANDARD AND FABRICATED ITEMS OF KITCHEN EQUIPMENT
AND EXTEND TO FLOOR SINKS WITH MIN. 1 INCH AIR GAP. ALL WASTE
LINES SHALL BE COPPER PIPING WITH SOLDERED FITTINGS WHERE
REQUIRED. EXPOSED LINES SHALL BE INSULATED WITH TAPE.
7. PROVIDE AND INSTALL ALL EQUIPMENT TRIM INCLUDING FAUCETS
AND SINK WASTES.
8. ALL HOT AND COLD WATER SERVICE LINES TO FIXTURES SHALL BE
INSULATED, ESPECIALLY EXPOSED HOT WATER LINES.
9. ALL HORIZONTAL PIPING LINES CONNECTED TO EQUIPMENT SHALL
BE RUN AT THE HIGHEST POSSIBLE ELEVATION AND NOT LESS
THAN 6 INCH ABOVE FLOOR. ALL PIPING ROUGHING-IN SHALL BE
STUBBED AND RUN IN WALLS, NO EXCEPTIONS.
10. ALL MECHANICAL & PLUMBING "QF" DRAWINGS ARE INDICATED FOR
REFERENCE AND CONVENIENCE OF THE ARCHITECT, ENGINEERS,
CONTRACTOR AND/OR SUB-CONTRACTORS. REFER TO THE
CORRESPONDING RELATED SECTONS FOR EXACT REQUIREMENTS.
WATER PRESSURE SHALL BE VERIFIED BY THE K.E.C. AND
COORDINATED WITH THE G.C. PLUMBER SHALL PROVIDE PRESSURE
REDUCING VALVE FOR DISHWASHER AND OTHERS AS REQUIRED.
HOT WATER OR COLD WATER - AS NOTED ON PLAN
FLOOR DRAIN
FLOOR SINK WITH HALF GRATING
WASTE - DIRECT
EXHAUST DUCT
MAKE-UP AIR PLENUM
MECHANICAL & PLUMBING SYMBOLS
DUPLEX CONVENIENCE OUTLET
CEILING DROP CORD
JUNCTION BOX
JUNCTION BOX - WALL MOUNTED
ELECTRICAL SYMBOLS
S
V
SWITCH
VAPORPROOF LIGHT
BUILDING WORK SYMBOLS
NON-COMBUSTIBLE, HEATPROOF WALL
CHANNEL IRON FOR HOOD SUPPORT
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
Fi le
P at h:
Pl ot D at e:
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
FI
N
AL
S
U
BM
IT
TA
L
/2 1/
C :\R ev it_
Pr oj ec ts
\1
9_
E_ C en tra l_ aq ue ve do .rv t
/1 5/
:0
3:
P M
QF001
KI
TC
H
EN
N O
TE
S
LE
G
EN
D
FY
C H
IL
D
D
EV
EL
O
PM
EN
T C
EN
TE
R H
O N
O
LU
LU
D
IS
TR
IC
T
FT
. S
H
AF
TE
R
, H
AW
AI
I
H O
'O H
U I'I
A
- J
V
I.
M
IZ
O
I.
M
IZ
O
R . Y
O
SH
ID
A
/0
9/
SC
H O
FI
EL
D B
AR
R
AC
KS
O
AH
U , H
AW
AI
I
BI
SH
O P
ST
, S
U
IT
E
H
O N
O
LU
LU
, H
AW
AI
I 9
FI
N
AL
S
U
BM
IT
TA
L N
O T
FO
R
C O
N
ST
R U
C
TI
O N
"3'-6"3'-0"
Condenser Curb - Refer to Architectural Drawings.
3'-0" Required Clearance Around Condenser - Verify Electrical Code
Air Curtain - Refer to Architectural Drawings
5A5A
22A
2A
13 14
29A
Kitchen Notes Ceiling Height: 9'-0" Corner Guards: Refer to Architectural Drawings.
7 Hand Sink By Plumber
Hand Sink By Plumber
3'-0" M
IN
2A
2A
DISH / POT
WASHING
Cart Parking
Cart Parking
WALK-IN
FREEZER
WALK-IN
REFRIGERATOR
Insulated Refrigeration Lines thru 6" Ø Conduits - Up Along Wall and Run Within Hung Ceiling Space to Coil Connection
14 14 14 14 14 14 14
15 15 15 15 15 1514
REMOTE WALK-IN CONDENSER
QF502QF502
Insulated Refrigeration Lines from Remote Condenser: G.C. | K.E.C.
shall coordinate with all Sub-Contractors to ensure straight line runs and avoid bends.
4'-2"
CCTV EQUIPMENT
ROOM
LAUNDRY ROOM
ELECTRICAL
ROOM 2
KITCHEN
F
HALLWAY
MECHANICAL
FIRE PUMP RM
DRY FOOD
STORAGE
113A
MECHANICAL YARD
SCALE: 1/4" = 1'-0"A1 OVERALL KITCHEN | REMOTE CONDENSER EQUIPMENT PLAN
0 2' 4' 8'
QF101
QF101
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
Fi le
P at h:
Pl ot D at e:
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
FI
N
AL
S
U
BM
IT
TA
L
/2 1/
C :\R ev it_
Pr oj ec ts
\1
9_
E_ C en tra l_ aq ue ve do .rv t
/1 5/
:0
3:
P M
QF100
O
VE
R
AL
L
KI
TC
H
EN
E
Q U
IP
M
EN
T
R
EM
O
TE
C
O N
D
EN
SE
R
EQ
U
IP
M
EN
T
PL
AN
FY
C H
IL
D
D
EV
EL
O
PM
EN
T C
EN
TE
R H
O N
O
LU
LU
D
IS
TR
IC
T
FT
. S
H
AF
TE
R
, H
AW
AI
I
H O
'O H
U I'I
A
- J
V
I.
M
IZ
O
I.
M
IZ
O
R . Y
O
SH
ID
A
/0
9/
SC
H O
FI
EL
D B
AR
R
AC
KS
O
AH
U , H
AW
AI
I
BI
SH
O P
ST
, S
U
IT
E
H
O N
O
LU
LU
, H
AW
AI
I 9
A
C
BD
AADD
BBCC
KEY TO
INTERIOR
ELEVATION
KEY PLAN
A B C
D
E
FI
N
AL
S
U
BM
IT
TA
L N
O T
FO
R
C O
N
ST
R U
C
TI
Air Curtain - Refer to Architectural Drawings
5A5A
22A
2A
13 14
29A
Kitchen Notes Ceiling Height: 9'-0" Corner Guards: Refer to Architectural Drawings.
7 Hand Sink By Plumber
Hand Sink By Plumber
3'-0" M
IN
2A
2A
DISH / POT
WASHING
Cart Parking
Cart Parking
WALK-IN
FREEZER
WALK-IN
REFRIGERATOR
14 14 14 14 14 14 14
15 15 15 15 15 1514
QF502QF502
LAUNDRY ROO
ELECTRICAL
ROOM 2
KITCHEN
113 DRY FOOD
STORAGE
113A
"3'-6"3'-0"
Condenser Curb - Refer to Architectural Drawings.
3'-0" Required Clearance Around Condenser - Verify Electrical Code
REMOTE WALK-IN CONDENSER
Insulated Refrigeration Lines from Remote Condenser: G.C. | K.E.C.
shall coordinate with all Sub-Contractors to ensure straight line runs and avoid bends.
4'-2"
MECHANICAL YARD
SCALE: 1/4" = 1'-0"H13
KITCHEN EQUIPMENT PLAN
0 2' 4' 8'
FOODSERVICE EQUIPMENT SCHEDULE
ITEM NO. QTY. DESCRIPTION REMARKS | ADA COMPLIANT NOTATIONS I II
1 1 AIR CURTAIN | UNHEATED REFER TO ARCHITECTURAL | MECHANICAL SECTIONS X
2 1 DRY STORAGE SHELVING | CHROME WIRE 4 SHELVES | SIZE: 1'-6" WIDE X 4'- 0" LONG X 74 12 " HIGH POSTS X
2A 5 DRY STORAGE SHELVING | CHROME WIRE 4 SHELVES | SIZE: 1'-6" WIDE X 3'- 0" LONG X 74 12 " HIGH POSTS X 3 2 REFRIGERATION SYSTEM, REMOTE DOUBLE STACKED | RACK MOUNTED FOR OUTDOOR INSTALLATION X 4 1 ASSEMBLY WALK-IN REFRIGERATOR & FREEZER 7' - 6" W X 6' -10" D X 7' - 6" H | 8" DEPRESSED FLOOR, SS EXT & INT X 5 7 WALK-IN STORAGE SHELVING | EPOXY WIRE 4 SHELVES | SIZE: 2'-0" WIDE X 3'- 0" LONG X 74 12 " HIGH POSTS X
5A 2 WALK-IN STORAGE SHELVING | EPOXY WIRE 4 SHELVES | SIZE: 1'-6" WIDE X 3'- 0" LONG X 74 12 " HIGH POSTS X 6 1 DUNNAGE RACK, SINGLE TIER MILK CRATE SIZE: 2'-0" WIDE X 3'- 0" LONG X 12 " HIGH X
7 1 HAND SINK | FOOD PREP BY PLUMBER | REFER TO MECHANICAL SECTION X
8 1 MIXER | 30 QUART | FLOOR MODEL - X
9 - SPARE NUMBER ( NOT USED ) - X
10 1 REFRIGERATOR | 1 SECTION | REACH-IN - X
11 1 WORK TABLE | UNDERSHELF | OVERSHELVES | DRAWER ADA: 34" HIGH | 2'-6" WIDE X 6'-0" LONG X
12 1 UNDERCOUNTER ICE MAKER 120/1 | PROVIDE WATER FILTER SIZED BY MANUFACTURER X
13 3 CART | 3 SHELF | PRE-SCHOOL - X
14 12 CART | 3 SHELF | TODDLER - X
15 6 CART | 3 SHELF | INFANT - X
16 1 WORK TABLE | UNDERSHELF | NO OVERSHELF | DRAWER ADA: 34" HIGH | 2'-6" WIDE X 8'-0" LONG X 17 1 WORK TABLE | UNDERSHELF | DOUBLE OVERSHELVES ADA: 34" HIGH | 2'-6" WIDE X 6'-0" LONG | 20" X 20" X 12" D. SINKS X
18 1 WORK TABLE | UNDERSHELF | DRAWER ADA: 34" HIGH | 2'-6" WIDE X 6'-0" LONG | OVERSHELF WITH
UTENSIL RACK X
19 1 TILT SKILLET | 30 GALLON 208/3
20 1 COMBI - OVEN | DOUBLE DECK 208/3/4-WIRE SYSTEM | REVERSE OSMOSIS WATER FILTER | 12 - 18" X
26" SHEET PANS | AUTOMATIC SELF-CLEANING & DESCALING X
21 1 WORK TABLE - 20" | PORTABLE PORTABLE FOR SERVICE ACCESS TO COMBI-OVEN ITEM NO. 20 X
22 1 EXHAUST HOOD W/ MAKE-UP AIR PLENUM BOX |
S/S WALL FLASHING TYPE I X
23 1 HOOD FIRE SUPPRESSION SYSTEM INSTALL PER UFC-600-01, NFPA 17A (2017), NFPA 96 (2017) AND
OTHER FIRE CODE REQUIREMENTS X
24 1 6 OPEN ELEMENT TOP RANGE WITH OVEN 208/3 X
25 1 S/S TROUGH WITH GRATING - X
26 1 HAND SINK | WARE WASHING BY PLUMBER | REFER TO MECHANICAL SECTION X
27 1 SCRAP SINK WITH PRE-RINSE SCRAP SINK PROVIDED WITH REMOVABLE SCRAP BASKETS X
28 1 WALL SHELF | S/S WIRE SIZE: 1'-6" WIDE X 6'- 0" LONG X
29 1 3 COMPARTMENT SINKS 1'-6" WIDE X 2'- 0" LONG X 1'-2" DEEP SINKS X
29A 1 SINK HEATER 208/3 | MEETS USACE STANDARD CRITERIA OF 180° SANITIZING X
30 1 POT & PAN RACK | SS 4'-0" WIDE X 2'- 0" LONG X 1'-2" DEEP SINKS X
31 1 CLEAN DISHTABLE | DOUBLE OVERSHELVES - X
32 1 BOOSTER HEATER BUILT INTO DISHWASHER ITEM NO. 33 X
33 1 DISHWASHER | TALL | SINGLE RACK 180 DEGREE HW FINAL RINSE | BUILT - IN 70° RISE BOOSTER HEATER X 34 1 VAPOR HOOD WITH MAKE-UP AIR PLENUM BOX | TYPE II 4'-0" WIDE X 4'- 0" LONG X 2'-6" HIGH
35 1 TRASH RECEPTACLE 32 GALLON | 21" DIAMETER | GREY X
36 1 SOILED DISHTABLE OVERHEAD SLANTED RACK SHELVES X
37 1 SCRAP SINK WITH PRE-RINSE SCRAP SINK PROVIDED WITH REMOVABLE SCRAP BASKETS X
38 1 SS HOSE REEL | WALL MOUNTED +5'-0" TO BOTTOM OF
SPRAY VALVE REEL RINSE CONTROL BOX ASSEMBLY X
39 1 DESK 24" X 48" X
LOGISTICAL CLASS:
I - CONTRACTOR FURNISHED CONTRACTOR INSTALLED (CFCI)
II - GOVERNMENT FURNISHED GOVERNMENT INSTALLED (GFGI)
B13
KITCHEN REMOTE CONDENSER PLAN
0 2' 4' 8'
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
Fi le
P at h:
Pl ot D at e:
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
FI
N
AL
S
U
BM
IT
TA
L
/2 1/
C :\R ev it_
Pr oj ec ts
\1
9_
E_ C en tra l_ aq ue ve do .rv t
/1 5/
:0
3:
P M
QF101
KI
TC
H
EN
E Q
U
IP
M
EN
T
R
EM
O
TE
C O
N D
EN
SE
R
EQ
U
IP
M
EN
T
PL
AN
S C
H
ED
U
LE
FY
C H
IL
D
D
EV
EL
O
PM
EN
T C
EN
TE
R H
O N
O
LU
LU
D
IS
TR
IC
T
FT
. S
H
AF
TE
R
, H
AW
AI
I
H O
'O H
U I'I
A
- J
V
I.
M
IZ
O
I.
M
IZ
O
R . Y
O
SH
ID
A
/0
9/
SC
H O
FI
EL
D B
AR
R
AC
KS
O
AH
U , H
AW
AI
I
BI
SH
O P
ST
, S
U
IT
E
H
O N
O
LU
LU
, H
AW
AI
I 9
A
C
BD
AADD
BBCC
KEY TO
INTERIOR
ELEVATION
KEY PLAN
A B C
D
E
FI
N
AL
S
U
BM
IT
TA
L N
O T
FO
R
C O
N
ST
R U
C
TI
J
J
J
E39
E4A E4
SL
SL
S VP+60"
S
VP+60"
Sp Sp
E10
E18
E12
E11
JE4B
T
T
E8
E18
E17
Sp
E20
J
E22 E23
E24
E29A
E33
E33A
E19
E20.A
J
J
J J
J J J
J
1" Ø CONDUIT BY ELECTRICIAN FOR CONTROL
WIRING RUN IN HUNG CEILING SPACE FROM
REMOTE CONDENSER LOCATED IN
MECHANICAL YARD.
STORAGE
124B
TOILET
121A
LAUNDRY ROOM
ELECTRICAL
ROOM 2
KITCHEN
7'
2" 7'
3/
DRY FOOD
STORAGE
113A
J
E3A
J
E3C
E3B
1" Ø CONDUIT BY ELECTRICIAN UNDERGROUND | UP ALONG
WALL & RUN WITHIN HUNG CEILING SPACE TO KITCHEN WALK-IN
REFRIGERATOR & FREEZER COIL CONNECTIONS.
E3D
2 - 6" Ø CONDUIT STUB UP +6" BY ELECTRICIAN.
CAP AS REQUIRED TO PREVENT WATER
AND/OR DEBRIS FROM FILLING OPEN CONDUIT.
FOOD SERVICE EQUIPMENT ELECTRICAL SCHEDULE
ITEM NO. DESCRIPTION AMPS VOLTS PHASE CONN. HT. REMARKS
E1 AIR CURTAIN - - - - PROVIDED UNDER OTHER SECTIONS | ARCHITECTURAL | MECHANICAL
E3A REFRIGERATION SYSTEM, REMOTE FREEZER 9.7 208 3 STUB UP
+4" K.E.C. SHALL COORDINATE MINIMUM AMPACITY WITH MANUFACTURER
E3B REFRIGERATION SYSTEM, REMOTE FREEZER - - - -
1" Ø CONDUIT WITH FIVE (5) WIRES BY ELECTRICIAN FOR FREEZER
DEFROST CONTROLS. ELECTRICIAN SHALL COLOR CODE WIRES:
1-COMMON / 2-HEATERS / 1-FAN COIL / 1-TERMINATION
E3C REFRIGERATION SYSTEM, REMOTE REFRIGERATOR 5.2 208 3 STUB UP
+4" K.E.C. SHALL COORDINATE MINIMUM AMPACITY WITH MANUFACTURER
E3D REFRIGERATION SYSTEM, REMOTE - - - -
2 - 6" Ø CONDUITS BY ELECTRICIAN RUN UNDERGROUND WITH LARGE 24"
MINIMUM RADIUS BENDS FOR REFRIGERATION LINES. CONDUITS SHALL
BE STUBBED UP +6"
E4 WALK-IN REFRIGERATOR & FREEZER
3 - 15.0 120 1 +102"
E4: (2) ELECTRICAL CONNECTIONS TO LIGHTS / DOOR DEFROST HEATER
CABLES / DRAINLINE HEATERS / TEMPERATURE ALARMS
E4A: (1) ELECTRICAL CONNECTION TO REFRIG. EVAPORATOR COIL
8.0 208 1 +102" E4B: 8A/208/1 FREEZER COIL VIA REFRIGERATION SYSTEM (E3C)
E8 MIXER | 30 QUART | FLOOR MODEL 9.5 120 1 +24" CORD & PLUG | NEMA 5-15P | DEDICATED OUTLET
E10 REFRIGERATOR | 1 SECTION | REACH-IN 7.0 120 1 +28" CORD & PLUG | NEMA 5-15P | DEDICATED OUTLET
E11 WORK TABLE | UNDERSHELF | OVERSHELVES | DRAWER 2 - 8.0 120 1 +48" CONVENIENCE OUTLETS
E12 UNDERCOUNTER ICE MAKER 5.3 120 1 +18" CORD & PLUG | NEMA 5-15P | DEDICATED OUTLET
E17 WORK TABLE | UNDERSHELF | DOUBLE OVERSHELVES 2 - 8.0 120 1 +48" CONVENIENCE OUTLET | MOUNT HORIZONTALLY
E18 WORK TABLE | UNDERSHELF | DRAWER 2 - 8.0 120 1 +48" CONVENIENCE OUTLETS | MOUNT HORIZONTALLY
E19 TILTING SKILLET | 30 GALLON 33.3 208 3 +24" PROVIDE LOCKING HASP ON BREAKER SWITCH - " NO BREAKER IN ROOM "
E20 COMBI - OVEN | DOUBLE DECK 2 - 61.4A 208 3 +24" | 48" PROVIDE LOCKING HASP ON BREAKER SWITCH - " NO BREAKER IN ROOM "
| 70A BREAKER - 61.4 RUNNING AMPS
E20.A WATER FILTERING SYSTEM PUMP | COMBI - OVEN 8.0 120 1 +46" CONVENIENCE OUTLET | MOUNT HORIZONTALLY
E22 EXHAUST HOOD WITH MAKE - UP AIR PLENUM BOX 8.0 120 1 +48" HOOD LIGHT SWITCH | 1" Ø CONDUIT WITH CONTROL WIRING BY
ELECTRICIAN FROM TEMP SENSOR WITHIN HOOD TO EXHAUST FAN
E23 HOOD FIRE SUPPRESSION SYSTEM 15.0 120 1 +78" PER NFPA BULLETIN NO. 17A, 96 & UL 300
E24 6 OPEN ELEMENT TOP RANGE WITH OVEN 58.9A OR
19.1 kW 208 3 +12""
PROVIDE LOCKING HASP ON BREAKER SWITCH - " NO BREAKER IN ROOM "
| X - 62.0A | Y - 45.0A | Z - 54.0A |
E29A SINK HEATER 25A 208 3 (BAL) +18" PROVIDE LOCKING HASP ON BREAKER SWITCH - " NO BREAKER IN DISH
ROOM "
E32 BOOSTER HEATER - - - - BUILT INTO DISHWASHER ITEM NO. 33
E33 DISHWASHER | TALL | HI-TEMP | SINGLE RACK 45.4 208 3 +108"
PROVIDE LOCKING HASP ON BREAKER SWITCH - " NO BREAKER IN DISH
ROOM " | SINGLE POINT CONNECTION
E33A DISHWASHER | HI-TEMP DETERGENT DISPENSER 8.0 120 1 +108" DETERGENT DISPENSER FURNISHED & INSTALLED BY VENDOR
E34 VAPOR HOOD | TYPE II - - - - CONNECTION TO DISHWASHER VENT FAN CONTROL SWITCH | REFER TO
MECHANICAL DRAWINGS
E39 DESK 8.0 120 1 +48"
CONVENIENCE OUTLET | SEE ELECTRICAL DRAWINGS FOR VOICE/DATA
PORT TO ACCOMMODATE A COMPUTER & PHONE. INTERCOM DEVICE
AND TELEPHONE PER USACE STANDARD DESIGN CRITERA
SCALE: 1/4" = 1'-0"A1 KITCHEN EQUIPMENT PLAN & SCHEDULE
0 2' 4' 8'
SCALE: 1/4" = 1'-0"B16 REMOTE CONDENSER EQUIPMENT PLAN
0 2' 4' 8'
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
Fi le
P at h:
Pl ot D at e:
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
FI
N
AL
S
U
BM
IT
TA
L
/2 1/
C :\R ev it_
Pr oj ec ts
\1
9_
E_ C en tra l_ aq ue ve do .rv t
/1 5/
:0
3:
P M
QF102
KI
TC
H
EN
E Q
U
IP
M
EN
T
EL
EC
TR
IC
AL
P
LA
N
S C
H
ED
U
LE
FY
C H
IL
D
D
EV
EL
O
PM
EN
T C
EN
TE
R H
O N
O
LU
LU
D
IS
TR
IC
T
FT
. S
H
AF
TE
R
, H
AW
AI
I
H O
'O H
U I'I
A
- J
V
I.
M
IZ
O
I.
M
IZ
O
R . Y
O
SH
ID
A
/0
9/
SC
H O
FI
EL
D B
AR
R
AC
KS
O
AH
U , H
AW
AI
I
BI
SH
O P
ST
, S
U
IT
E
H
O N
O
LU
LU
, H
AW
AI
I 9
A
C
BD
AADD
BBCC
KEY TO
INTERIOR
ELEVATION
KEY PLAN
A B C
D
E
FI
N
AL
S
U
BM
IT
TA
L N
O T
FO
R
C O
N
ST
R U
C
TI
FS
FD
FD
FD
M17
M38
FD
FD
FS
FS
FS
FS
FSFS
M20
M27
M37
M33
Hand Sink By Plumber
M34
M29
M29A
M22A
M22A
M22
FD
M25
M19
M22
M33
M37
M4
Hand Sink By Plumber
M20
M34A
FS
M12
ACTIV
STORAGE
124B
TOILET
TOILET
121A
LAUNDRY ROO
ELECTRICAL
ROOM 2
KITCHEN
7'
2" 7'
3/
DRY FOOD
STORAGE
113A
FD
FOOD SERVICE EQUIPMENT MECHANICAL SCHEDULE
ITEM
NO. DESCRIPTION HW CW CONN.
HT. WASTE INDIRECT CONN
HT CFM REMARKS
M4 WALK-IN REFRIGERATOR & FREEZER - - - FS ● - - 1 18" Ø INSULATED COPPER DRAINLINE FROM COILS
TO F.S. BY K.E.C.
M12 UNDERCOUNTER ICE MAKER - 3/4" +14" FS ● - -
1/2" Ø COPPER DRAINLINE TO F.S. BY PLUMBER |
COLD WATER SUPPLY TO WATER FILTER TO 3/8" ICE
MAKER WATER INLET BY PLUMBER
M17 WORK TABLE | 2 - COMPARTMENT PREP SINKS 3/4" 3/4" +14" FS ● - -
140° HW CONNECTION TO FAUCET | INDIRECT
DRAINLINES TO FLOOR SINK BY PLUMBER | K.E.C.
SHALL PROVIDE 140° CAPABLE FAUCET
M19 TILTING SKILLET | 30 GALLON 3/4" 3/4" +24" - - - - HW & CW SUPPLY CONNECTION TO DOUBLE
PANTRY FAUCET
M20 COMBI - OVEN | DOUBLE STACKED | ELECTRIC - 2 - 3/4" +14" FS ● - -
2 - CW CONNECTIONS BY PLUMBER: 1 - MINIMUM
414 KPA I WATER SUPPLY TO WATER FILTER TO
COMBI OVEN / 1 - CONDENSATE | DRAIN: 2" HI-TEMP
RESISTANT PIPE | DRAINLINE TO FLOOR SINK BY
PLUMBER
M22 EXHAUST HOOD - - - - - - 3080 (2) 13" X 12" EXHAUST DUCT AT 1540 CFM EACH |
S.P.: -0.48" W.G.
M22A EXHAUST HOOD MAKE - UP AIR PLENUM BOX - - - - - - 1848 (2) 15" X 10" SUPPLY DUCT AT 924 CFM EACH |
S.P.: 0.10" W.G. EACH
M25 S/S FLOOR TROUGH WITH GRATING - - - 3.5" FD - - - 3.5" O.D. WASTE PIPE
M27 SCRAP SINK WITH PRE-RINSE 3/4" 3/4" +14" FS ● - -
140° HW CONNECTIONS TO 140° CAPABLE
PRE-RINSE SPRAY - MINIMUM 1.15 GPM AT 414 KPA |
INDIRECT WASTE LINE TO FLOOR SINK BY PLUMBER
M29 3 COMPARTMENT SINKS 2 - 3/4" 2 - 3/4" +14" FS ● - -
140° HW CONNECTIONS TO FAUCETS | FLOOR SINK
SHALL BE SIZED SO SINKS CAN BE DRAINED
SIMULTANEOUSLY AND WILL NOT OVERFLOW
AND/OR BACK-UP | INDIRECT WASTE LINE TO
FLOOR SINK BY PLUMBER
M29A SINK HEATER 3/4" - +14" - - - - 140° HW CONNECTION TO SINK HEATER
M33 DISHWASHER | TALL | SINGLE RACK 3/4" - +80" FS ● - -
42.9 GPH HW AT 120° TO BUILT-IN BOOSTER HTR -
.74 GPM / 103-172 KPA - PLUMBER SHALL PROVIDE
PRV WITH INTERNAL THERMAL EXPANSION BYPASS
/ "T" HW TO DETERGENT DISPENSER +90" | WATER
HAMMER ARRESTOR BY PLUMBER | PLUMBER TO
EXTEND DRAINLINES TO FLOOR SINK
M33A DISHWASHER DRAIN WATER TEMPERING & DRAIN - 3/4" +14" 1-1/2" ● - -
CW CONNECTION TO DRAIN WATER TEMPERING BY
PLUMBER | 1-1/2" DRAIN TO FLOOR SINK BY
PLUMBER
M34 VAPOR HOOD | TYPE II - - - - - - 800 (1) 8" X 10" EXHAUST DUCT AT 800 CFM |
S.P.: 0.25" W.G.
M34A VAPOR HOOD | TYPE II | MAKE-UP AIR PLENUM BOX - - - - - - 480 8" X 10" SUPPLY DUCT AT 480 CFM | S.P.: 0.10" W.G.
M37 SCRAP SINK WITH PRE-RINSE 3/4" 3/4" +14" FS ● - -
140° HW CONNECTIONS TO 140° CAPABLE FAUCET &
PRE-RINSE SPRAY - MINIMUM 1.15 GPM AT 414 KPA
(60 PSI) | FLOOR SINK SHALL BE SIZED SO SINKS
CAN BE DRAINED SIMULTANEOUSLY AND WILL NOT
OVERFLOW AND/OR BACK-UP | INDIRECT WASTE
LINE TO FLOOR SINK BY PLUMBER
M38 HOSE REEL 3/4" 3/4" +24" - - - -
CW CONNECTION TO TO DRAIN WATER TEMPERING
BY PLUMBER | 1-1/2" DRAIN TO FLOOR SINK BY
PLUMBER | 2.65 GPM AT 552 KPA (80 PSI)
SCALE: 1/4" = 1'-0"A1 KITCHEN EQUIPMENT MECHANICAL PLAN & SCHEDULE
0 2' 4' 8'
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
Fi le
P at h:
Pl ot D at e:
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
FI
N
AL
S
U
BM
IT
TA
L
/2 1/
C :\R ev it_
Pr oj ec ts
\1
9_
E_ C en tra l_ aq ue ve do .rv t
/1 5/
:0
3:
P M
QF103
KI
TC
H
EN
E Q
U
IP
M
EN
T M
EC
H
AN
IC
AL
P
LA
N
S
C H
ED
U
LE
FY
C H
IL
D
D
EV
EL
O
PM
EN
T C
EN
TE
R H
O N
O
LU
LU
D
IS
TR
IC
T
FT
. S
H
AF
TE
R
, H
AW
AI
I
H O
'O H
U I'I
A
- J
V
I.
M
IZ
O
I.
M
IZ
O
R . Y
O
SH
ID
A
/0
9/
SC
H O
FI
EL
D B
AR
R
AC
KS
O
AH
U , H
AW
AI
I
BI
SH
O P
ST
, S
U
IT
E
H
O N
O
LU
LU
, H
AW
AI
I 9
A
C
BD
AADD
BBCC
KEY TO
INTERIOR
ELEVATION
KEY PLAN
A B C
D
E
FI
N
AL
S
U
BM
IT
TA
L N
O T
FO
R
C O
N
ST
R U
C
TI
5"
WALL OPENINGS FOR REFRIGERATION LINES
RUN IN HUNG CEILING SPACE BY G.C.
COORDINATE LOCATIONS WITH K.E.C.
INSULATED REFRIGERATION LINES RUN IN 6" Ø
CONDUIT-STUB UP +6" BY ELECTRICIAN UP
ALONG WALL & RUN IN HUNG CEILING SPACE
TO AREA ABOVE WALK-INS & DOWN TO COIL
CONNECTIONS BY K.E.C.
INSULATED REFRIGERATION LINES
RUN IN HUNG CEILING SPACE TO
AREA ABOVE WALK-INS & DOWN TO
COIL CONNECTIONS BY K.E.C.
4'-2" 2'-4"
6" HIGH CURB BY G.C. -
REFER TO ARCHITECTURAL
DRAWINGS
G.C. NOTES:
1. GENERAL CONTRACTOR ( G.C. ) SHALL PROVIDE 8" LEVEL FLOOR
DEPRESSION FREE OF PROJECTING AGGREGATE FOR WALK-IN COLD
2. 1 18" COPPER DRAINLINE FROM EVAPORATOR COILS TO FLOOR SINK
LOCATIONS, SHALL BE FURNISHED AND INSTALLED BY THE KITCHEN
EQUIPMENT CONTRACTOR (K.E.C.), SHALL BE INSULATED TO AVOID
SWEATING AND SHALL EXIT WALK-INS TO FLOOR SINK APPROX. 12" A.F.F.
3. ALL WALLS IN CONTACT WITH OR WITHIN 6" OF RANGE, COMBI-OVEN
AND TILTING SKILLET SHALL BE CONSTRUCTED OF NON-COMBUSTIBLE
HEATPROOF MATERIAL. VERIFY FIRE MARSHALL'S SPECIAL RULINGS.
4. GENERAL CONTRACTOR SHALL FURNISH AND INSTALL CHANNEL FRAMING
OR "Z" BAR IN POSITION AS INDICATED ON THIS BUILDING WORK FOR
INSTALLATION OF HOOD HANGER RODS BY THE KITCHEN EQUIPMENT
CONTRACTOR / COORDINATE LOCATIONS OF CHANNEL FRAMING WITH K.E.C.
REFER TO STRUCTURAL DRAWINGS FOR EXACT REQUIREMENTS FOR
SUPPORT FRAMING.
5. GENERAL CONTRACTOR SHALL PROVIDE LEVEL FLOOR AT ALL EQUIPMENT
LOCATIONS FOR LEVELED INSTALLATION OF COOKING EQUIPMENT. FLOOR
STORAGE ROOMS TO EFFECT A 1/2" RAMP AT ENTRANCE DOOR.
PROVIDE TILE, SETTING BED AND FINISHED FLOOR BASES AS INDICATED.
CONCRETE FILL SHALL BE REINFORCED WITH 10 GA. WELDED MESH,
6" ON CENTERS BOTH WAYS. REFER TO ARCHITECTURAL / STRUCTURAL
DRAWINGS FOR EXACT REQUIREMENTS.
CAN BE SLOPED TO FLOOR DRAIN FROM EXTERIOR EDGE OF EQUIPMENT /
COORDINATE WITH KITCHEN EQUIPMENT CONTRACTOR.
REFER TO ARCHITECTURAL DRAWINGS FOR EXACT REQUIREENTS.
1'-3"1'-8"
5'-6"
SLOPE THIS AREA 1/ 8" TO FLOOR DRAIN.
REFER TO ARCHITECTURAL DRAWINGS.
4'-8"
G .C
N
O T
E N
O
G.C. NOTE
NO. 4
G .C
N
O T
E N
O
16'-4"
1'-9" 5'-0" 2'-10" 5'-0" 1/2" Ramp Up 1/2" Ramp Up
G .C
N
O T
E N
O
G.C. NOTE NO. 5
G.C. NOTE NO. 1
GENERAL CONTRACTOR | K.E.C.
SHALL COORDINATE WITH ALL
TRADES TO "ENSURE" STRAIGHT
REFRIGERATION LINE RUNS TO BE
INSTALLED WITH MINIMAL BENDS.
" 1'-3" 1'-7"
2'-4"
QF501
G.C. SHALL DEPRESS THIS
AREA 4" - 6" BELOW FINISHED
FLOOR LINE. REFER TO
ARCHITECTURAL DRAWINGS
FOR EXACT REQUIREMENTS
QF501
QF501
2"1'-7"3'-7"1'-6"
2'-6"
G
.C N
O T
E N
O
CCTV EQUIPMENT
ROOM
LAUNDRY ROOM
ELECTRICAL
ROOM 2
KITCHEN
F
HALLWAY
MECHANICAL
FIRE PUMP RM
DRY FOOD
STORAGE
113A
MECHANICAL YARD
Full Height Wall 8'-3"6'-2"
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
Fi le
P at h:
Pl ot D at e:
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
FI
N
AL
S
U
BM
IT
TA
L
/2 1/
C :\R ev it_
Pr oj ec ts
\1
9_
E_ C en tra l_ aq ue ve do .rv t
/1 5/
:0
3:
P M
QF104
KI
TC
H
EN
E Q
U
IP
M
EN
T
BU
IL
D
IN
G
W O
R K
PL
AN
FY
C H
IL
D
D
EV
EL
O
PM
EN
T C
EN
TE
R H
O N
O
LU
LU
D
IS
TR
IC
T
FT
. S
H
AF
TE
R
, H
AW
AI
I
H O
'O H
U I'I
A
- J
V
I.
M
IZ
O
I.
M
IZ
O
R . Y
O
SH
ID
A
/0
9/
SC
H O
FI
EL
D B
AR
R
AC
KS
O
AH
U , H
AW
AI
I
BI
SH
O P
ST
, S
U
IT
E
H
O N
O
LU
LU
, H
AW
AI
I 9
A
C
BD
AADD
BBCC
KEY TO
INTERIOR
ELEVATION
KEY PLAN
A B C
D
E
SCALE: 1/4" = 1'-0"A1 OVERALL KITCHEN | REMOTE CONDENSER EQUIPMENT PLAN
0 2' 4' 8'
FI
N
AL
S
U
BM
IT
TA
L N
O T
FO
R
C O
N
ST
R U
C
TI
4" URETHANE
ROOF PANEL
4" URETHANE
WALL PANEL
PVC
PLUG
CAM-ACTION METAL
PANEL FASTENER
15lb. FELT
SLIP SHEET
(*) CONCRETE SUBSTRATE 4000 PSI CONCRETE
WITH 1" SQ. WIRE CLOTH 20 GA ZINC COATED
THICKSET TILE
FLOOR BY G.C.
INTERIOR TILE
BASE BY G.C.
METAL LATH
BY G.C.
GROUT
BY G.C.
18G GALVANIZED STEEL FLOOR
CHANNEL "BOOT" TYP. 23" O.C.
TW0 2" LAYERS BOARD-FORM
URETHANE FLOOR INSULATION
ASPHALT EMULSION & FOIL COATED
VAPOR BARRIER SUB-FLOOR MEMBRANEHILTI POWER DRIVEN
ANCHOR PIN ±23" O.C.
D
PR
SN
EXTERIOR TILE
BASE BY G.C.
2"
4" 8'
-0
1/
2"
1/
2" 4"
8" 1/
2"
4" URETHANE
HINGED DOOR
DOOR PERIMETER
HEATER
ADJUSTABLE
SILL WIPER
JAMB HEATER
14G STAINLESS STEEL
JAMB ANGLE GUARD
REMOVABLE STAINLESS STEEL
SILL PLATE WITH HEATER
4" URETHANE
ROOF PANEL
4" URETHANE
WALL PANEL
PVC
PLUG
CAM-ACTION METAL
PANEL FASTENER
D
PR
SN
8" 1/
2"
1/
2" 8'
-0
4"
4"
1/ 2"
(*) REFER TO ARCHITECTURAL & STRUCTURAL
SECTIONS FOR WAIL-IN REFRIGERATOR & FREEZER
WEARING FLOOR & EXACT THICKNESS REQUIREMENTS
FOR AIR ENTRAINED CONCRETE OR EQUAL
" REFER TO SHEET QF507 WALK-IN ACCESSORY DETAILS"
FOR EXACT DETAIL REQUIREMENTS / KITCHEN CONTRACTOR (KEC)
REFER TO ARCHITECTURAL/STRUCTURAL DRAWINGS FOR FLOOR DEPRESSION REQUIREMENTS
AND GENERAL CONTRACTOR (GC) SHALL COORDINATE.
8" x 8" SLAB BLOCK-OUT BY
GENERAL CONTRACTOR
CONNECTIONS BY PLUMBER
S/S BASKET ASSEMBLY W/ PERFORATED REMOVABLE COVER
S/S TROUGH BY KITCHEN EQUIPMENT CONTRACTOR. FINAL
AND STRAINER W/ 3" O.D. TAIL PIECE WELDED TO
1'-2"
12"
BY GENERAL CONTRACTOR
FINISH FLOOR
LO
W6"
PO
IN
T 4"
PO
IN
T
HI
GH
S/S ANCHOR
PLUMBER (TYPICAL)
WASTE PIPE BY
LEAD AND OAKUM CAULK
1'-4"
BUILDING SLAB
EPOXY GROUT SETTING BED
S/S ANCHOR
ANTI-SLIP FIBERGLASS FLOOR
GRATING BY KITCHEN
EQUIPMENT CONTRACTOR.
CLEAR SPACE BETWEEN BARS
NOT TO EXCEED 1/2". SECTION
NOT TO EXCEED 2'-3" IN LENGTH.
ALL DRAIN LINES REQUIRE A
COPPER DRAIN LINE
"P" TRAP
INSULATED SUCTION LINE & LIQUID LINE
AIR FLOW COIL
COPPER UNION TO
REFRIGERATION
CONTRACTOR
TO SEAL
PENETRATION
BE SUPPLIED &
INSTALLED BY
PLUMBER.
DRAIN LINE TO EXIT
45° @ BACK OF COIL.
AT EARLIEST POSSIBLE
EXIT FROM COOLER
DISTANCE.
MINIMUM OF 1/2" FALL PER FT.
PROVIDE AIR
GAP BETWEEN
DRAIN & DRAIN
LINE.
FLOOR SINK
OR RECEPTOR
NOTE: RUN EACH DRAIN SEPARATELY
(LOW TEMPERATURE ONLY)
ELECTRIC HEATER SPIRALED AND
TAPED ON FREEZER DRAIN LINE
BY REFRIGERATION CONTRACTOR.
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
Fi le
P at h:
Pl ot D at e:
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
FI
N
AL
S
U
BM
IT
TA
L
/2 1/
C :\R ev it_
Pr oj ec ts
\1
9_
E_ C en tra l_ aq ue ve do .rv t
/1 5/
:0
3:
P M
QF501
KI
TC
H
EN
E Q
U
IP
M
EN
T
BU
IL
D
IN
G
W O
R K
D
ET
AI
LS
-1
FY
C H
IL
D
D
EV
EL
O
PM
EN
T C
EN
TE
R H
O N
O
LU
LU
D
IS
TR
IC
T
FT
. S
H
AF
TE
R
, H
AW
AI
I
H O
'O H
U I'I
A
- J
V
I.
M
IZ
O
I.
M
IZ
O
R . Y
O
SH
ID
A
/0
9/
SC
H O
FI
EL
D B
AR
R
AC
KS
O
AH
U , H
AW
AI
I
BI
SH
O P
ST
, S
U
IT
E
H
O N
O
LU
LU
, H
AW
AI
I 9
FI
N
AL
S
U
BM
IT
TA
L N
O T
FO
R
C O
N
ST
R U
C
TI
O N
SCALE: 1-1/2" = 1'-0"F1 EXTERIOR FLOOR AND WALL CONNECTION
SCALE: 1-1/2" = 1'-0"
DOOR SILL SECTION
SCALE: N.T.S.K12
"REFERENCE ONLY" - SECTION THROUGH FLOOR TROUGH
ITEM NO. 25 - S/S FLOOR TROUGH
SCALE: N.T.S.C12 TYPICAL REFRIGERATION COIL DRAINLINE INSTALLATION
F8
7'-4"
5'-6" NTS1'-10" NTS
TOTAL WEIGHT: 1300 LBS.
5/8"Ø THREADED HANGER RODS BY K.E.C.
9' -0
8"
3" x 3" x 1/4" CONTINUOUS CHANNEL IRON FOR HOOD
SUPPORT BY G.C. REFER TO STRUCTURAL DRAWINGS
6' -8
2'
-6
S/S MAKE-UP AIR
PLENUM BOX
UL CLASSIFIED
S/S FILTER
LED LIGHTS
S/S HOOD
1'-6" MIN
DUCT EXTENSION
BY HVAC CONTR.
TYP. ALL HOODS
S/S WALL FLASHING
REFER TO DETAIL 3/QF502
STRUCTURAL SUPPORT MEMBER - REFER TO STRUCTURAL
DRAWINGS
9' -0
" C
EI
LI
N
G
3"
4'-0"
10" 1'-7"
6"
MIN.
10" 4"NTS
2.
5"
1'-6" NTS
6' -8
STRUCTURAL SUPPORT MEMBER - REFER TO
STRUCTURAL DRAWINGS
3" x 3" x 1/4" CONTINUOUS CHANNEL IRON FOR HOOD
SUPPORT BY G.C. REFER TO STRUCTURAL DRAWINGS
S/S HOOD
TOTAL WEIGHT: 260 LBS.
5/8"Ø THREADED
HANGER RODS BY
K.E.C.
9' -0
" C
EI
LI
N
G
2' -6
8"
SILICONE SEALANT
PANEL JOINT
20 GA S/S WALL FLASHING
SECTION AT BASE END
SILICONE SEALANT
FINISH WALL
HEM
COVED TILE BASE BY
FASTEN TO WALL W/
WALL BY
H
EM
S/S SCREWS
FLASHING BETWEEN PANEL JOINTS
20 GA S/S WALL FLASHING
CRIMPED EVERY 12"
PANEL JOINT PANEL JOINT
2 12" 4'-0" 2 12"
1" 1 14" 2 12" 1 14"
1 2"
FLASHING & CHANNEL EDGING SHALL HAVE MITERED JOINTS FULLY WELDED &
GROUND SMOOTH. EDGING SHALL BE FULLY WELDED & GROUND SMOOTH.
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
Fi le
P at h:
Pl ot D at e:
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
FI
N
AL
S
U
BM
IT
TA
L
/2 1/
C :\R ev it_
Pr oj ec ts
\1
9_
E_ C en tra l_ aq ue ve do .rv t
/1 5/
:0
3:
P M
QF502
KI
TC
H
EN
E Q
U
IP
M
EN
T
BU
IL
D
IN
G
W O
R K
D
ET
AI
LS
-2
FY
C H
IL
D
D
EV
EL
O
PM
EN
T C
EN
TE
R H
O N
O
LU
LU
D
IS
TR
IC
T
FT
. S
H
AF
TE
R
, H
AW
AI
I
H O
'O H
U I'I
A
- J
V
I.
M
IZ
O
I.
M
IZ
O
R . Y
O
SH
ID
A
/0
9/
SC
H O
FI
EL
D B
AR
R
AC
KS
O
AH
U , H
AW
AI
I
BI
SH
O P
ST
, S
U
IT
E
H
O N
O
LU
LU
, H
AW
AI
I 9
FI
N
AL
S
U
BM
IT
TA
L N
O T
FO
R
C O
N
ST
R U
C
TI
O N
SCALE: 1-1/2" = 1'-0"F3 HOOD SECTION ITEM NO. 22
SCALE: N.T.S.A9 S/S WALL FLASHING DETAIL
SCALE: 1-1/2" = 1'-0"
HOOD SECTION ITEM NO. 34F14
AND BE PRESENT DURING THE TESTING OF EXHAUST SYSTEMS.
WORK BETWEEN MECHANICAL AND ELECTRICAL CONTRACTORS
FOOD SERVICE EQUIPMENT CONTRACTOR SHALL COORDINATESERVICE EQUIPMENT LOCATED BELOW HOOD(S). CALL FIRE
HEAD PLACEMENT OVER EACH APPLIANCE.
INSPECTOR @ 523-4186
FIRE EXTINGUISHING SYSTEMS, INCLUDING CROSS SECTIONAL
DETAILS OF COOKING APPLIANCES, INDICATING EXTINGUISHING
COMPLETE SHOP DRAWINGS AND BROCHURES FOR HOOD
FOOD SERVICE EQUIPMENT CONTRACTOR SHALL PROVIDE
THE PROTECTION OF KITCHEN GREASE HOODS AND DUCTS SHALL
CONFORM TO NFPA BULLETINS NO.17A AND NO.96, AND U.L. 300
THE PRESENCE OF FIRE INSPECTOR PRIOR TO USE OF FOOD
HOOD ACCEPTANCE TEST (PUFF TEST) SHALL BE PERFORMED IN
DESIGN AND INSTALLATION OF THE FIRE SUPPRESSION SYSTEM FOR ELECTRICAL CONTACTORS OR SHUNT TRIP SHALL BE FURNISHED
AND INSTALLED BY ELECTRICIAN FOR THE EQUIPMENT
LOCATED BELOW HOODS:
4.
3.
2.
1.
NOTES:
ITEM NO. 19 - TILTING SKILLET
ITEM NO. 20 - COMBI-OVENS
ITEMS AS REQUIRED THAT ARE NOT LISTED OR INDICATED
MECH. CONTR.
DUCT BRANCH
LINE
EXHAUST DUCT BY
INSTALLED BY PLUMBER
EQUIPMENT CONTRACTOR AND
VALVE FURNISHED BY KITCHEN
MECHANICAL GAS SHUT-OFF
SYSTEM TIE-IN BY
BUILDING FIRE ALARM
MANUAL RELEASE
CONTROL HEAD
AND MICROSWITCH
STATION
DIVISION 28. SEE
WET CHEMICAL TANK
NO.96 AND U.L. 300
NFPA BULLETINS NO. 17A AND
HOODS SHALL COMPLY WITH
DESIGN AND INSTALLATION OF
(BY PLUMBER)
GAS SUPPLY LINE
POWER SUPPLY TO
(BY ELECTRICIAN)
ELEC. COOKING EQUIP.
ELECTRICAL CONTACTOR
(BY ELECTRICIAN)
(BY ELECTRICIAN)
ELECTRICAL
SERVICE PANEL
OR SHUNT TRIP
(BY PLUMBER)
COOKING EQUIP.
GAS LINE TO
CONTRACTOR
BY KITCHEN EQUIPMENT
HOOD LINE
EQUIPMENT BRANCH
PLENUM BRANCH
LINE
ITEM NO. 24 - 6 OPEN ELEMENT RANGE WITH OVEN.
HOOD SUPPRESSION NOTES:
1. AUTOMATIC POWER, FUEL AND VENTILATION SHUTOFF:
AUTOMATIC FIRE EXTINGUISHING SYSTEMS SHALL BE
INTERCONNECTED TO THE FUEL OR CURRENT SUPPLY FOR
COOKING EQUIPMENT. THE INTERCONNECTION SHALL BE
ARRANGED TO AUTOMATICALLY SHUT OFF ALL COOKING
EQUIPMENT AND ELECTRICAL RECEPTACLES WHICH ARE
LOCATED UNDER THE HOOD WHEN THE SYSTEM IS ACTIVATED
SHUTOFF VALVES OR SWITCHES SHALL BE OF THE TYPES
THAT REQUIRE MANUAL OPERATION TO RESET, UFC 1997,
SECTION 1006.2.4.1
2. MANUAL ACTIVATION DEVICE:
A READILY ACCESSIBLE MANUAL ACTIVATION DEVICE INSTALLED
AT AN APPROVED LOCATION SHALL BE PROVIDED FOR DRY
CHEMICAL, WET CHEMICAL AND CARBON DIOXIDE SYSTEMS.
THE ACTIVATION DEVICE IS ALLOWED TO BE MECHANICALLY OR
ELECTRICALLY OPERATED. IF ELECTRICAL POWER IS USED,
THE SYSTEM SHALL BE CONNECTED TO A STANDBY POWER
SYSTEM AND A VISUAL MEANS SHALL BE PROVIDED TO SHOW
THAT THE EXTINGUISHING SYSTEM IS ENERGIZED. INSTRUCTIONS
FOR OPERATION THE FIRE-EXTINGUISHING SYSTEM SHALL BE
POSTED ADJACENT TO MANUAL ACTIVATION DEVICES.
UFC 1997, 1006.2.6
3. FIRE EXTINGUISHERS:
A SODIUM BICARBONATE OR POTASSIUM BICARBONATE DRY-
CHEMICAL-TYPE PORTABLE FIRE EXTINGUISHER HAVING A
MINIMUM RATING OF 40-B SHALL BE INSTALLED WITHIN 30 FEET
OF COMMERCIAL FOOD HEAT-PROCESSING EQUIPMENT, AS
MEASURED ALONG AN UNOBSTRUCTED PATH OF TRAVEL. IN
ACCORDANCE WITH UFC STANDARD 10-1. UFC 1997, 1006.2.7
4. CARBON DIOXIDE SYSTEMS:
COMMERICAL-TUYPE COOKING EQUIPMENT PROTECTED BY AN
AUTOMATIC CARBON DIOXIDE EXTINGUISHING SYSTEM SHALL BE
ARRANGED TO SHUT OFF THE VENTILATION SYSTEM UPON
ACTIVATION. UFC 1997., 1006.2.4.2
5. FIRE ALARM:
A SIGNAL SHALL BE PROVIDED TO SHOW THAT THE SYSTEM HAS
OPERATED, THAT PERSONNEL RESPONSE IS NEEDED, AND THAT
THE SYSTEM IS IN NEED OF RECHARGE. THE EXTINGUISHING
SYSTEM SHALL BE CONNECTED TO THE FIRE ALARM SYSTEM. IF
PROVIDED, IN ACCORDANCE WITH THE REQUIREMENTS OF NFPA
72 NATIONAL FIRE ALARM CODE, SO THAT THE ACTUATION OF THE
EXTINGUISHING SYSTEM WILL SOUND THE FIRE ALARM AS WELL
AS PROVIDE THE FUNCTION OF THE EXTINGUISHING SYSTEM.
NFPA 17A, 2004 EDITION, SECTION 3-2.4.5.
6. DEEP FAT FRYER SET BACK:
ALL DEEP FAT FRYERS SHALL BE INSTALLED WITH AT LEAST A
16 INCH (406.4mm) SPACE BETWEEN THE FRYER AND SURFACE
FLAMES FROM ADJACENT COOKING EQUIPMENT. UFC 1997.
SECTION 1003.2.2.1 AS AMENDED.
7. AIR ACCEPTANCE TEST:
PRIOR TO THE COMMENCEMENT OF THE INITIAL COOKING
OPERATIONS, A SATISFACTORY AIR ACCEPTANCE TEST OF
THE SYSTEM SHALL BE MADE TO ACCORDANCE WITH THE
MANUFACTURE'S INSTRUCTIONS. THE ACCEPTANCE TEST
MAY BE WITNESSED BY THE CHIEF. UFC 1997, SECTION
1006.2.2.2 AS AMENDED.
FIRE CODE NOTES:
1. APPLICATION - 2021 NFPA 1, CHAPTER 50:
50.1.1* THE DESIGN, INSTALLATION, OPERATION, INSPECTION, AND
MAINTENANCE OF ALL PUBLIC AND PRIVATE COMMERCIAL COOKING
EQUIPMENT SHALL COMPLY WITH THIS CHAPTER AND NFPA 96,
STANDARD FOR VENTILATION CONTROL AND FIRE PROTECTION OF
50.2.1.1 COOKING EQUIPMENT USED IN PROCESSES PRODUCING
SMOKE OR GREASE-LADEN VAPORS SHALL BE EQUIPPED WITH AN
EXHAUST SYSTEM THAT COMPLIES WITH ALL THE EQUIPMENT AND
50.4.3.2* COOKING EQUIPMENT THAT PRODUCES GREASE-LADEN
VAPORS AND THAT MIGHT BE A SOURCE OF IGNITION OF GREASE IN
THE HOOD, GREASE REMOVAL DEVICE, OR DUCT SHALL BE
50.4.4.1 FIRE-EXTINGUISHING EQUIPMENT SHALL INCLUDE BOTH
AUTOMATIC FIRE-EXTINGUISHING SYSTEMS AS PRIMARY PROTECTION
AND PORTABLE FIRE EXTINGUISHERS AS SECONDARY BACK UP.
3. PORTABLE FIRE EXTINGUISHERS - 2021 NFPA 1, CHAPTER 50:
50.4.11.1* PORTABLE FIRE-EXTINGUISHING SHALL BE SELECTED AND
INSTALLED IN KITCHEN COOKING AREAS IN ACCORDANCE WITH
SECTION 13.6 AND SHALL BE SPECIFICALLY LISTED FOR SUCH USE.
4. SIMULTANEOUS OPERATION - 2021 NFPA 1, CHAPTER 50:
50.4.5.1 FIXED PIPE EXTINGUISHING SYSTEMS IN A SINGLE HAZARD
AREA SHALL BE ARRANGED FOR SIMULTANEOUS AUTOMATIC
OPERATION UPON ACTUATION OF ANYONE OF THE SYSTEMS.
COMMERCIAL COOKING OPERATIONS.
PERFORMANCE REQUIREMENTS OF THIS CHAPTER.
PROTECTED BY FIRE-EXTINGUISHING EQUIPMENT.
50.4.5.2 SIMULTANEOUS OPERATION SHALL NOT BE REQUIRED
WHERE FIXED PIPE EXTINGUISHING SYSTEM IS AN AUTOMATIC
SPRINKLER SYSTEM.
50.4.5.3 SIMULTANEOUS OPERATION SHALL NOT BE REQUIRED
WHERE DRY OR WET CHEMICAL SYSTEM SHALL BE IS USED TO
PROTECT COMMON EXHAUST DUCTWORK BY ONE OF THE
METHODS SPECIFIED IN NFPA 17 OR NFPA 17A.
5. FUEL AND ELECTRIC POWER SHUTOFF - 2021 NFPA 1, CHAPTER 50:
50.4.6.1 UPON ACTUATION OF ANY FIRE-EXTINGUISHING SYSTEM
FOR A COOKING OPERATION, ALL SOURCES OF FUEL AND ELECTRIC
POWER THAT PRODUCE HEAT TO ALL EQUIPMENT PROTECTED BY
THE SYSTEM SHALL AUTOMATICALLY SHUT OFF.
6. MANUAL ACTUATION - 2021 NFPA 1, CHAPTER 50:
50.4.7.1 ALL SYSTEMS SHALL HAVE BOTH AUTOMATIC AND MANUAL
METHODS OF ACTUATION.
50.4.7.1.1 AT LEAST ONE MANUAL ACTUATION DEVICE SHALL BE LOCATED
IN A MEANS OF EGRESS AND BE LOCATED BETWEEN 42 INCH AND 48 INCH
7. SYSTEM ANNUNCIATION - 2021 NFPA 1, CHAPTER 50:
50.4.8.1 UPON ACTUATION OF AN AUTOMATIC FIRE-EXTINGUISHING
SYSTEM, AN AUDIBLE ALARM OR VISUAL INDICATOR SHALL BE
PROVIDED TO SHOW THAT THE SYSTEM HAS ACTUATED.
50.4.8.2 WHERE A FIRE ALARM SIGNALING SYSTEM IS SERVING THE
OCCUPANCY WHERE THE EXTINGUISHING SYSTEM IS LOCATED, THE
ACTUATION OF THE AUTOMATIC EXTINGUISHING SYSTEM IS LOCATED,
THE ACTUATION OF THE AUTOMATIC FIRE-EXTINGUISHING SYSTEM
SHALL ACTUATE THE FIRE ALARM SIGNALING SYSTEM IN ACCORDANCE
50.4.6.3 GAS APPLIANCES NOT REQUIRING PROTECTION BUT LOCATED
UNDER THE SAME VENTILATION EQUIPMENT WHERE PROTECTED
APPLIANCES ARE LOCATED SHALL ALSO BE AUTOMATICALLY SHUT OFF
UPON ACTUATION OF THE EXTINGUISHING SYSTEM.
50.4.6.4 SHUTOFF DEVICES SHALL REQUIRE MANUAL RESETTING PRIOR
50.4.7.1.3 MANUAL ACTUATION DEVICES INSTALLED IN LOCATIONS
WHERE ACCIDENTAL OPERATION COULD OCCUR SHALL PROVIDED
WITH A GUARD WHERE REQUIRED.
50.7.1.2.4 ALL DEEP FAT FRYERS SHALL BE INSTALLED WITH AT
LEAST A 16 IN. SPACE BETWEEN THE FRYER AND SURFACE FLAMES
FROM ADJACENT COOKING EQUIPMENT.
50.7.1.2.5 WHERE A STEEL OR TEMPERED GLASS BAFFLE PLATE IS
INSTALLED AT A MINIMUM 8 IN. IN HEIGHT BETWEEN THE FRYER
AND SURFACE FLAMES OF THE ADJACENT APPLIANCE, THE
50.7.1.2.5.1 IF THE FRYER AND THE SURFACE FLAMES ARE AT
DIFFERENT HORIZONTAL PLANES, THE MINIMUM HEIGHT 8 IN. SHALL
BE MEASURED FROM THE HIGHER OF THE TWO.
REQUIREMENT FOR A 16 IN. SPACE SHALL NOT APPLY.
8. COOKING EQUIPMENT - 2021 NFPA 1, CHAPTER 50:
50.4.9.1 WHERE ELECTRICAL POWER IS REQUIRED TO OPERATE THE
FIXED AUTOMATIC FIRE-EXTINGUISHING SYSTEM, THE SYSTEM SHALL
BE PROVIDED WITH A RESERVE POWER SUPPLY AND BE MONITORED
50.4.9.2 WHERE FIXED AUTOMATIC FIRE-EXTINGUISHING SYSTEMS
INCLUDES AUTOMATIC MECHANICAL DETECTION AND ACTUATION AS
A BACKUP DETECTION SYSTEM, ELECTRICAL POWER MONITORING AND
50.4.9.3 SYSTEM SUPERVISION SHALL NOT BE REQUIRED WHERE A
FIRE-EXTINGUISHING SYSTEM(S) IS INTERCONNECTED OR INTERLOCKED
WITH THE COOKING EQUIPMENT POWER SOURCE(S) SO THAT IF THE
A RESERVE POWER SUPPLY SHALL NOT BE REQUIRED.
9. SYSTEM SUPERVISION - 2012 NFPA 1, CHAPTER 50:
BY A SUPERVISORY ALARM EXCEPT AS PERMITTED IN 50.4.9.2.
FIRE-EXTINGUISHING SYSTEM BECOMES INOPERABLE DUE TO
POWER FAILURE, ALL SOURCES OF FUEL OR ELECTRIC POWER THAT
HOOD SHALL AUTOMATICALLY SHUT OFF.
50.4.9.4 SYSTEM SUPERVISION SHALL NOT BE REQUIRED WHERE AN
AUTOMATIC FIRE-EXTINGUISHING SYSTEM INCLUDES AUTOMATIC
MECHANICAL DETECTION AND ACTUATION, IS ELECTRICALLY CONNECTED
TO A LISTED FIRE-ACTUATED WATER-WASH SYSTEM FOR SIMULTANEOUS
OPERATION OF BOTH SYSTEMS.
13.1.1 THE AHJ SHALL HAVE THE AUTHORITY TO REQUIRE THAT CONTRUCTION
DOCUMENTS FOR ALL FIRE PROTECTION SYSTEMS BE SUBMITTED FOR REVIEW
AND APPROVAL AND A PERMIT BE ISSUED PRIOR TO THE INSTALLATION,
10. ACCEPTANCE TESTING - 13.1 GENERAL, 2012 NFPA 1, CHAPTER 13
REHABILITATION, OR MODIFICATION. FURTHER, THE AHJ SHALL HAVE THE
AUTHORITY TO REQUIRE THAT FULL ACCEPTANCE TESTS OF THE SYSTEMS BE
PERFORMED IN THE AHJ'S PRESENSE PRIOR TO FINAL SYSTEM CERTIFICATION.
2. GENERAL REQUIREMENTS - 2021 NFPA 1, CHAPTER 50:
BY KITCHEN CONTRACTOR
CONDUIT AND CABLE
TO BUILDING ALARM
SYSTEM
DETERMINED REQUIRED)
ELECTRICAL PANEL
LINKS BY K.E.C.
CONDUIT, CABLE & FUSIBLE
BY ELECTRICAL CONTR.
W/ MICROSWITCH
POWER TO EQUIPMENT)
SHOP DRAWINGS.
NOTE:
(SHUNT TRIP TO SHUT-OFF PANEL AS
WITH ELECTRIC POWER
& INSTALLED BY ELECTRICAL CONTRACTOR
SHUT-OFF POWER TO EQUIPMENT BY K.E.C.
INDIVIDUAL EQUIPMENT CONTACTOR TO
PANEL. (RELAY TO SHUT-OFF
120V SERVICE
BY ELEC. CONTR.
CONDUIT & CONTROL WIRING BY
ELECTRICAL CONTRACTOR FROM
MICROSWITCH TO ELECTRICAL
ELECTRICAL CONDUIT &
WIRING TO EQUIPMENT
EXHAUST HOOD
BY K.E.C.
ALL ELECTRICAL POWER TO EQUIPMENT UNDER HOOD IS
REQUIRED TO BE SHUT-OFF ONCE SYSTEM IS ACTIVATED.
VERIFY REQUIREMENTS WITH APPROVED MANUFACTURER'S
HOOD FIRE PROTECTION
SYSTEM CONTROL HEAD
AND/OR EQUIPMENT
ELECTRIC EQUIPMENT
TO REMOTE PULL
STATION BY K.E.C.
RELAY
MANUAL RESET
WIRING BY
CONTROL
CONDUIT &
ELEC. CONTR.
FA501 & FA601
TO FUEL OR POWER BEING RESTORED.
ABOVE FLOOR.
50.4.7.1.2 THE MANUAL ACTUATION DEVICE SHALL CLEARLY IDENTIFY
THE HAZARD PROTECTED AND PROVIDED WITH INSTRUCTIONS FOR
ITS USE.
WITH THE REQUIREMENTS OF NFPA 72.
50.7.1.2.1 ALL LISTED APPLIANCES SHALL BE INSTALLED WITH IN
ACCORDANCE WITH THE TERMS OF THEIR LISTING AND THE
MANUFACTURER'S INSTRUCTIONS.
50.7.1.2.2* SOLID FUEL USED FOR FLAVORING WITHIN A GAS-OPERATED
APPLIANCE SHALL BE IN A SOLID FUEL HOLDER (SMOKER BOX) THAT
IS LISTED WITH THE EQUIPMENT.
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
Fi le
P at h:
Pl ot D at e:
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
FI
N
AL
S
U
BM
IT
TA
L
/2 1/
C :\R ev it_
Pr oj ec ts
\1
9_
E_ C en tra l_ aq ue ve do .rv t
/1 5/
:0
3:
P M
QF503
H O
O D
F
IR
E
SU
PP
R
ES
SI
O N
S
YS
TS
EM
R
EF
ER
EN
C E
D
IA
G R
AM
S
FI
R E
C O
D E
N O
TE
S
FY
C H
IL
D
D
EV
EL
O
PM
EN
T C
EN
TE
R H
O N
O
LU
LU
D
IS
TR
IC
T
FT
. S
H
AF
TE
R
, H
AW
AI
I
H O
'O H
U I'I
A
- J
V
I.
M
IZ
O
I.
M
IZ
O
R . Y
O
SH
ID
A
/0
9/
SC
H O
FI
EL
D B
AR
R
AC
KS
O
AH
U , H
AW
AI
I
BI
SH
O P
ST
, S
U
IT
E
H
O N
O
LU
LU
, H
AW
AI
I 9
FI
N
AL
S
U
BM
IT
TA
L N
O T
FO
R
C O
N
ST
R U
C
TI
O N
SCALE: N.T.S.J3 HOOD FIRE EXTINGUISHING SYSTEM REFERENCE DIAGRAM
SCALE: N.T.S.J13 HOOD FIRE PROTECTION SYSTEM REFERENCE WIRING DIAGRAM
UNDERSHELF
16 GA S/S
TOP & SPLASH
14 GA S/S
DRAWER
ITEM NO. 11 - S/S WORK TABLE W/ DRAWER
K7
16 GA S/S
OVERSHELF
K10
UNDERSHELF
16 GA S/S
14 GA S/S TOP
DRAWER
ITEM NO. 16 - S/S WORK TABLE W/ DRAWER
K18
ICE MACHINE
ITEM NO. 12
ICE MACHINE
ITEM NO. 12
ITEM NO. 17 - WORK TABLE WITH SINKS & OVERSHELVES
CROSSRAIL
AT BACK
1'-31 2" 1'-8" 1" 1'-8"
CONTINUOUS S/S FRONT
1'-31 2"
TOP & SPLASH
14 GA S/S
16 GA S/S
OVERSHELF
WASTE
1'-2"
ITEM NO. 18 - WORK TABLE WITH OVERSHELF & UTENSIL HOOKS
CROSSRAIL AT
BACK
TOP & SPLASH
14 GA S/S
DRAWER
S/S UTENSIL HOOKS AT 8" O.C.
16 GA S/S OVERSHELF 1'-3"
6' -8
9- 0"
C E
IL
IN
G H
E
IG
H T
ITEM NO. 22 - EXHAUST HOOD WITH
MAKE-UP AIR PLENUM BOX & S/S FLASHING
ITEM NO. 24 - 6 OPEN
ELEMENT TOP WITH OVEN
ITEM NO. 21 -
WORKTABLE /
PORTABLE
ITEM NO. 19 -
TILTING SKILLET /
30 GALLON
S/S WALL FLASHING
S/S WALL FLASHING
16 GA. S/S
UNDERSHELF
14 GA.
S/S TOP
ITEM NO. 20 - COMBI-OVEN /
DOUBLE STACKED
REVERSE OSMOSIS (R.O.)
WATER SYSTEM FOR
COMBI-OVEN
G.C. SHALL PROVIDE
BACKING PLATE FOR
MOUNTING R.O. SYSTEM.
CAPABLE OF SUPPORTING
MIN. 50 LBS.
COOKING LINE
F7
6'-0"
A15
3' -0
1'
-6
1' -0
6'-0"
1'-3" 1'-3"
1'-11"
MIN. CLEAR
2"
8"
2"
3' -0
1' -6
1'
-0
2"
3' -0
1' -6
1'
-0
8'-0" 2'-6"
2"
3' -0
6'-0" 2'-6"
2"
8"
3' -0
2"
2' -6
F17
2"
1'-8"4"
2'-6"
TO FS
3' -0
2"
3'-0"
8"
6' -6
A.
F.
F.
TO
T O
P O
F R
.O . S
YS
TE
M
1'-6"
2"
2"
WATER FILTER
ITEM NO. 12
2'-6"2'-6"
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
Fi le
P at h:
Pl ot D at e:
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
FI
N
AL
S
U
BM
IT
TA
L
/2 1/
C :\R ev it_
Pr oj ec ts
\1
9_
E_ C en tra l_ aq ue ve do .rv t
/1 5/
:0
3:
P M
QF504
EQ
U
IP
M
EN
T
EL
EV
AT
IO
N S
SE
C
TI
O N
S-
FY
C H
IL
D
D
EV
EL
O
PM
EN
T C
EN
TE
R H
O N
O
LU
LU
D
IS
TR
IC
T
FT
. S
H
AF
TE
R
, H
AW
AI
I
H O
'O H
U I'I
A
- J
V
I.
M
IZ
O
I.
M
IZ
O
R . Y
O
SH
ID
A
/0
9/
SC
H O
FI
EL
D B
AR
R
AC
KS
O
AH
U , H
AW
AI
I
BI
SH
O P
ST
, S
U
IT
E
H
O N
O
LU
LU
, H
AW
AI
I 9
FI
N
AL
S
U
BM
IT
TA
L N
O T
FO
R
C O
N
ST
R U
C
TI
O N
SCALE: 3/4" = 1'-0"K3 ELEVATION
SCALE: 3/4" = 1'-0"K7 SECTION
SCALE: 3/4" = 1'-0"K10 SECTION
SCALE: 3/4" = 1'-0"K13 ELEVATION
SCALE: 3/4" = 1'-0"K18 SECTION
SCALE: 3/4" = 1'-0"F2 ELEVATION
SCALE: 3/4" = 1'-0"F7 SECTION
SCALE: 3/4" = 1'-0"F12 ELEVATION
SCALE: 3/4" = 1'-0"F17 SECTION
SCALE: 3/4" = 1'-0"A5 ELEVATION
SCALE: 3/4" = 1'-0"A15 SECTION
CONTINUOUS S/S FRONT
ITEM NO. 29 - SOILED DISHTABLE | POT SINKS
6'-0"
CROSSRAIL AT
BACK
16 GA S/S
UNDERSHELF
16 GA S/S
UNDERSHELF
3" 1'
-2
2'-6"
1'-6"
2'-6"
6"
10'-9"
3' -1
2"
CROSSRAIL AT
BACK
3' -1
1' -2
1' -2
3"
8" 11 2"
2" 2" 1'-6" 1" 1'-6" 1'-6"1" 21
2" 1'-6" 2'-21 2"2'-21
2"
1' -2
5'-0"
S/S DRAIN LINE
TO DISHTABLE
ITEM NO. 34 - VAPOR HOOD
16 GA S/S
UNDERSHELF
4'-0"
ADDITIONAL FRAMING AT
PERIMETER OF SINKS TO PREVENT
SAGGING - TYPICAL ALL
14 GA S/S TOP / SPLASH
CROSSRAIL FRONT TO
BACK AND AT BACK
SCRAP SINK WITH REMOVABLE
GRATING & (2) PERFORATED
SCRAP BASKETS WITH WELDED
SLIDE BARS
14 GA S/S RACK SHELF
ITEM NO. 36 & 37 - SOILED DISHTABLE | SCRAP SINK WITH PRE-RINSE ITEM NO. 31 - CLEAN DISHTABLE | DOUBLE OVERSHELVES ITEM NO. 30 - POT & PAN RACK | S/S
ITEM NO. 35 -
TRASH
RECEPTACLE
ITEM NO. 33 -
DISHWASHER
A8
F14
8'-7"
(VERIFY)
6'-1"
(VERIFY)
K10
F17 A3
8"
1' -8
TWIST WASTE LEVER
DRAIN WITH OVERFLOW
CROSSRAILS AT
SIDES & BACK
3' -1
2'-6"
MIN. 14 GA S/S
RACK SHELF
1'-9"
4' -5
2"
2'-6"
2"
8"
3' -1
" 11
2"
3"
4'-0" 2'-0" 2'-7"
2"
3" 1'
-2
3' -0
1 2"
3"
2"
8"
1' -6
1'
-0 " 11
2"
1'-2"
2"
2'-6"
8' -0
4' -1
0"
3' -0
4"
G.C. SHALL PROVIDE
BACKING PLATES FOR ALL
WALL MOUNTED SHELVING
AND WALL MOUNTED
ACCESSORIES.
(TYPICAL ALL)
A.
F.
F.
T
O B
O
TT
O M
O F
TH
E
H O
SE
R
EE
L
VA
LV
E
ITEM NO. 38 -S/S HOSE REEL | CONTROL BOX ASSEMBLY
8"
CONTROL BOX
ASSEMBLY
S/S HOSE REEL
ASSEMBLY WITH
SPRAY VALVE
A.
F.
F.
T
O B
O
TT
O M
TH
E
C O
N
TR
O L
PA
N
EL
FI
N
IS
H
ED
C
EI
LI
N G
H
EI
G H
T
A13
K14
DWG.
QF502
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
Fi le
P at h:
Pl ot D at e:
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
FI
N
AL
S
U
BM
IT
TA
L
/2 1/
C :\R ev it_
Pr oj ec ts
\1
9_
E_ C en tra l_ aq ue ve do .rv t
/1 5/
:0
3:
P M
QF505
EQ
U
IP
M
EN
T
EL
EV
AT
IO
N S
SE
C
TI
O N
S-
FY
C H
IL
D
D
EV
EL
O
PM
EN
T C
EN
TE
R H
O N
O
LU
LU
D
IS
TR
IC
T
FT
. S
H
AF
TE
R
, H
AW
AI
I
H O
'O H
U I'I
A
- J
V
I.
M
IZ
O
I.
M
IZ
O
R . Y
O
SH
ID
A
/0
9/
SC
H O
FI
EL
D B
AR
R
AC
KS
O
AH
U , H
AW
AI
I
BI
SH
O P
ST
, S
U
IT
E
H
O N
O
LU
LU
, H
AW
AI
I 9
FI
N
AL
S
U
BM
IT
TA
L N
O T
FO
R
C O
N
ST
R U
C
TI
O N
SCALE: 3/4" = 1'-0"K2 ELEVATION
SCALE: 3/4" = 1'-0"K10 SECTION
SCALE: 3/4" = 1'-0"K14 SECTION
SCALE: 3/4" = 1'-0"F3 ELEVATION SCALE: 3/4" = 1'-0"F17 SECTION
SCALE: 3/4" = 1'-0"A13 ELEVATION
SCALE: 3/4" = 1'-0"A18 SECTION
SCALE: 3/4" = 1'-0"A3 SECTION
SCALE: 3/4" = 1'-0"A8 SECTION
14 GA S/S ANGLE BRACKET
REFER TO SECTION DETAILS FOR WIDTH
PROVIDE BACKING PLATES ON ALL WALL
REQUIRING BACKING PLATES.
KITCHEN CONTRACTOR SHALL COORDINATE
NOTE: GENERAL CONTRACTOR SHALL
HUNG SHELVES AND/OR AT EQUIPMENT
OTHERWISE SPECIFIED
16 GA S/S - UNLESS
ENDS TURNED UP WHERE INDICATED
EACH BRACKET TO WALL
(2) 1/4" MOLLY BOLTS TO SECURE
2" 1-
1/ 2"
3/4"
5'-6" MAX. ON CENTERS
5"
LINE
WALL
9/16" R.
3/ 8"
1"i"
1 12"
1"
3"
1 12"
9/16" R.
APPROX. 3'-0" O.C.
A S
D E
T A
IL
E
D
14 GA S/S - UNLESS
OTHERWISE SPECIFIED
3" X 3" 14 GA S/S
CLIPS FASTENED TO
WALL WITH TWO MOLLY
BOLTS. PLACE CLIPS
3/ 4"
1"
3"
2"
1 4"
9/16" R. VERTICAL
AND HORIZONTAL
OTHERWISE SPECIFIED
14 GA S/S - UNLESS
COUNTER BODY
18 GA S/S
9/16" R.
AT 8" O.C.
UTENSIL HOOKS
1-1/2" X 1/4" FLAT
BAR WELDED TO…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .