W9128A-19-B-0001_Drawings_(Part_3_of_9).pdf
PDF 8 MB Posted
- Solicitation number
- W9128A-19-B-0001
About this file
Drawings (3 of 9)
View the file
Other files
Show all 32
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
F
IL
E N
U M
B E
R
S I Z
E
S U
B M
IT
T
E D
B Y
P L
O T
S C
A L
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T
N O
D A
T E
A P
P R
®of Engineers
US Army Corps
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
A N
S I
D R
H J G
-T
IT
L B
K .d g n
IS
S
U E
D A
T E
P A
C
IF
IC
O
C E
A N
H O
N O
L U
L U
H
A W
A
II
B O
W E
R S
A N
D K
U B
O T
A
M A
N A
G E
M E
N T
-4
A
K O
K I
S T
R E
E T
W A
IP
A
H U
H
I
W A
-1 -D
-0
JL
/H
D
J L
/F L
H D
JL
/H
D
A S
N O
T E
D
W A
-1 -D
-0
D
C
A
B
1 2 3 4 5
SHEET ID
IS
L
A N
D O
F H
A W
A
II
H
A W
A
II
P O
H A
K U
L O
A T
R A
IN
IN
G A
R E
A
T R
A
IN
IN
G
C O
M P
L E
X
B A
R R
A C
K S
P
H
F Y
M C
A P
N
O P
E R
A T
IO
N
A L
R E
A D
IN
E
S S
/2 /8
/2
/8
CONC SIDEWALK
SIDE ELEVATION
SL
WATER PROOF MEMBRANE
APPROVED EQUAL
BOBRICK #B985 OR
BASIS OF DESIGN:
HANGER
STAINLESS STEEL
HEAVY DUTY
BIBB
HOSE
C M
U F
A C
E
M
O O
T H
SEE CIVIL 5'-0"
P
L
IT
F A
C E
C M
U
5'-4" AFF
0'-0" FIN. FLR
METAL FRAME
METAL FRAME
LOCKERS
AT END OF
W/END PANEL
SLOPED TOP
BASE
ENCLOSED
COAT HOOK
HANGER ROD
LK-1
METAL SHELF
1' - 3"
NOTE:
8" CMU W/ SPLIT FACE ON EXTERIOR
SIDE AND SMOOTH FINISH ON INTERIOR.
1X3 WOOD TRIM
1 1/2" METAL DECKING OVER
PRE-ENGINEERED ROOF TRUSS
FILL TOP W/
OAKUM FOR TIGHT FIT
RIGID INSULATION (R=20).
LEAVE ANY EXPOSED ROOF
SURFACES, LOOSE EDGES
OR JOINTS)
EDGES & JOINTS. (DO NOT
SECURELY TAPE ALONG
COVER BOARD OVER
BOT. OF SOFFIT
MTL SOFFIT
END TRIM
FLASHING
SHEET
LEADERS & STRAPS @
36" O.C.
DOWNSPOUT WITH
PAINT FINISH, TYP.
METAL GUTTER
ANGLE
16 GA CLIP
GYPSUM BOARD
5/8" THICK STAINLESS STEEL/
CONTINUOUS MTL
STUD TRACK
CONTINUOUS 14 GA
FACIA
METAL GUTTER,
MASONRY SCREWS
3 5/8" DEEP 20 GA MTL
STUD @ 16" O.C.
7/8" DEEP 20 GA HAT
CHANNEL @ 16" O.C.
EDGE METAL
FOLD PANEL TO
ENGAGE EDGE
METAL FLASHING
7/8" DEEP 20 GA HAT
CHANNEL @ 16" O.C.
A-505
A2
FASCIA
FLASHING
SHEET METAL
STRAP
METAL
FIN GRADE ELEV
FIN SIDEWALK WHERE OCCURS
FINISH FLOOR
T.O. WALL
(E) CONC. SLAB
CMU WALL
ELEV: 0'-0"
UNDERLAYMENT OVER
SPLASH BLOCK, TYP
DRAWINGS
STRUCTURAL
FOOTING ,SEE
TYP
PRE-FINISHED STEEL
STANDING SEAM ROOF
ELEV: 8'-1" AFF , TYP
ELEV: 8'-8" AFF, TYP
FINISH CONC. FLOOR
(SEE CIVIL)
PER CIVIL
3'-0"8"
12" WIDE MTL
PANEL SOFFIT
A1
SCALE: 3/4" = 1'-0"
TYPICAL BOOT WASH DETAIL
C1
TYPICAL LOCKER SECTION
SCALE: 1 1/2"" = 1'-0"
0 1'
SCALE: 1 1/2" = 1'-0"
2'
0 1'
SCALE: 3/4" = 1'-0"
4'2' 3'
M
IS
C
B U
IL
D
IN
G
D E
T A
IL
S
A-503 A3
SCALE: 1 1/2" = 1'-0"
TYPICAL WALL SECTION DETAIL
L
IC
IT
A
T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
F
IL
E N
U M
B E
R
S I Z
E
S U
B M
IT
T
E D
B Y
P L
O T
S C
A L
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T
N O
D A
T E
A P
P R
®of Engineers
US Army Corps
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
A N
S I
D R
H J G
-T
IT
L B
K .d g n
IS
S
U E
D A
T E
P A
C
IF
IC
O
C E
A N
H O
N O
L U
L U
H
A W
A
II
B O
W E
R S
A N
D K
U B
O T
A
M A
N A
G E
M E
N T
-4
A
K O
K I
S T
R E
E T
W A
IP
A
H U
H
I
W A
-1 -D
-0
JL
/H
D
J L
/F L
H D
JL
/H
D
A S
N O
T E
D
W A
-1 -D
-0
D
C
A
B
1 2 3 4 5
SHEET ID
IS
L
A N
D O
F H
A W
A
II
H
A W
A
II
P O
H A
K U
L O
A T
R A
IN
IN
G A
R E
A
T R
A
IN
IN
G
C O
M P
L E
X
B A
R R
A C
K S
P
H
F Y
M C
A P
N
O P
E R
A T
IO
N
A L
R E
A D
IN
E
S S
/2 /8
/2
/8
DISPENSER
MOUNT SOAP
SURFACE
MIRROR
24"x36"
CLEARANCE
TOE AND KNEE
CLEARANCE
FLOOR
LAVATORY
TYPICAL SIDE ELEVATION
TYPICAL FRONT ELEVATION
LAVATORY -
TYPICAL FLOOR PLAN
LAVATORY -
ROBE HOOK
FINISH SCHEDULE
BUILDING NO. NAME HEIGHT FLOOR FINISH CEILING FINISH COMMENTS
145, 146, 147, 148
137, 138, 139, 144, BUILDING 135, 136, BARRACKS - LARGE 8' - 8" AFF
DOOR
FRAME
DOOR
GYP-1
FINISH LEGEND
SYMBOL MATERIAL PATTERN/COLOR COMMENTS
GYPSUM BOARD
CT-1 CERAMIC TILE
SLIGHTLY BEVELED MODIFIED STRAIGHT EDGE
GRT-1 GROUT
NON-STAINING, DRY-SET GROUT FOR WALLS, COLOR TO MATCH TILE
COMMERCIAL PORTLAND CEMENT GROUT, WATER RESISTANT,
CONC-1 SEALED CONCRETE
PT-1
CMU WALL)
PAINT (INTERIOR
PT-2
PT-3
& DOOR FRAMES)
PAINT (METAL DOORS
WILLIAMS - FOGGY DAY SW 6235
SEMI-GLOSS PAINT, COLOR: SHERWIN
COLOR: SHELL WHITE SW 8917
SEMI-GLOSS INTERIOR LATEX PAINT,
GP ADMIN - SMALL 8' - 8" AFF
8' - 8" AFF
8' - 8" AFF
8' - 8" AFF
DUPLEX
SHOWER/LATRINE
LATRINE ONLY
LAUNDRY
PT-3
PT-3
PT-3
PT-3
PT-3
PT-3
PT-3
PT-3
PT-3
PT-3
CEILING (GYP-1)
GYPSUM BOARD
CEILING (GYP-1)
GYPSUM BOARD
CEILING (GYP-1)
GYPSUM BOARD
CEILING (GYP-1)
GYPSUM BOARD
CEILING (GYP-1)
GYPSUM BOARD
CL
CL
TYP FRONT VIEW
URINAL
TYP PLAN VIEW
URINAL
SPACE
CLEAR
30" X 48"
EXT. WALL FINISH INT. WALL FINISH
CMU (PT-1)
PAINT ON
CMU (PT-2)
PAINT ON
CMU (PT-2)
PAINT ON
CMU (PT-1)
PAINT ON
CMU (PT-1)
PAINT ON
CMU (CMU-1)
PAINT ON
CMU (CMU-1)
PAINT ON
CMU (CMU-1)
PAINT ON
CMU (CMU-1)
PAINT ON
CMU (CMU-1)
PAINT ON
CMU-1
SEALER AS SPECIFIED
SEALER AS SPECIFIEDSEALED CMU
(CONC-1)
WATER REPELLENT
(CONC-1)
WATER REPELLENT
(CONC-1)
WATER REPELLENT
(CONC-1)
WATER REPELLENT
(CONC-1)
WATER REPELLENT
INDUSTRIAL COATING, COLOR: SHELL WHITE SW 8917
SEMI-GLOSS INTERIOR WATERBORNE LIGHT
BRIGHT GLAZED FINISH. COLOR: 0161 "URBAN PUTTY"
4 1/4" X 4 1/4", DUST PRESSED, WHITE NON-VITREOUS BODY,
LK-1
COLOR: 028 "GRAY"
15"x15"x48" TYPE STC-1 SINGLE TIER, ATTACHED TO 6" CLOSED BASE, W/OPEN SHELF
LOCKERS (METAL)
SEMI-GLOSS INTERIOR LATEX PAINT, COLOR: SHELL WHITE SW 8917
BUILDING 140, 149
142/142A
BUILDING 131/131A,
BUILDING 133
BUILDING 121
WALL
PAINT (INTERIOR CMU
TYPICAL TOILET MOUNTING DETAILS
ELEVATION PLAN
CL
OCCURS
WHERE
PARTITION
TOILET
TPD
WC
WC
T .O
H
O O
K
M
A X
OCCURS
WHERE
SCREEN
VIEW
URINAL
1'-4"
1'-4"
HOLDER
SHOWER SOAP
HOLDER
SOAP
SSC-1
COMPARTMENTS
SOLID PLASTIC SHOWER
GLAV. FLANGED BASE
MULTIPLE BASE CONNECTIONS 36"x36"
& DRESSING COMPARTEMENT.
BASIS OF DESIGN: SCRANTON PREFAB SHOWERS
IMPACT RESISTANT GYPBOARD ON CEILING
LAVATORY -
(TPD)
DISPENSER
PAPER
TOILET
(FEC)
CABINET
EXTINGUISHER
FIRE
C1
TYPICAL MOUNTING HEIGHT
SCALE: NTS
F
IN
IS
H
S C
H E
D U
L E
L
E G
E N
D T
Y P
IC
A
L M
O U
N T
IN
G
H E
IG
H
T
A-504
L
IC
IT
A
T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
F
IL
E N
U M
B E
R
S I Z
E
S U
B M
IT
T
E D
B Y
P L
O T
S C
A L
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T
N O
D A
T E
A P
P R
®of Engineers
US Army Corps
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
A N
S I
D R
H J G
-T
IT
L B
K .d g n
IS
S
U E
D A
T E
R E
P A
IR
B
Y R
E P
L A
C E
M E
N T
V A
R
IO
U S
B U
IL
D
IN
G
S
P O
H A
K U
L O
A T
R A
IN
IN
G A
R E
A
P T
A
IS
L
A N
D O
F H
A W
A
II
H
A W
II
P
C
IF
IC
O
C E
A N
H O
N O
L U
L U
H
A W
A
II
B O
W E
R S
A N
D K
U B
O T
A
M A
N A
G E
M E
N T
-4
A
K O
K I
S T
R E
E T
W A
IP
A
H U
H
I
W
A
-1
-R -0
W
A -1
-R
-0
/0
/1
IDENTIFICATION
SHEET
JL
/H
D
JL
/H
D G
M
JL
/H
D
A S
N O
T E
D
/0
/1
EXTERIOR WALL
ASSEMBLY
4" DIA. METAL
DOWNSPOUT
2" (W) X 3/16" THICK
PAINTED METAL
STRAP W/ 1/4" OC X 2"
SST BOLT W/ BLKG
FOLD PANEL
PANS TO ENGAGE
EDGE METAL
DOWNSLOPE PERIMETER
EDGE-METAL FLASHING
UNDERLAYMENT
METAL ROOF PANEL
PANEL CLIP
METAL GUTTER
GUTTER BRACKET
SUPPORT
GUTTER SPACER
PLACED BETWEEN
BRACKETS
METAL DOWNSPOUT
CONT FASCIA
SEE STRUCT
END TRIM
CLIP ANGLE
SEE STRUCT
METAL
SOFFIT
SHEET METAL
FLASHING FASCIA
METAL ROOFING
PENTRATION
CONDUIT
RUNOFF
TO FACILITATE
SEALANT TOOLED
FLASHING
PENETRATION
PREFORMED
OF SEALANT
CONTINUOUS BEAD
RING IN
SET SCUREMENT
PENETRATION
FIX PANEL AT
DECK SO AS NOT TO
PANEL AND NOT TO
FLANGE TO ROOF
FLASHING COLLAR
FASTENERS SECURE
GASKETED
DRAWBAND
SST
1'- 4"
1'-0"
EASE ALL OF
EDGES, TYP.
ELEVATION
PLAN
SECTION
METAL DOWNSPOUT,
SEE DETAIL C2/A-505
SPLASH BLOCK,
SEE DETAIL C3/A-505
FINISH FLOOR
EXHAUST DUCT
DRAFT DAMPER
SPRING LOADED BACK
SET CAP IN SEALANT
WALL CAP
CMU EXP. FASTENER, TYP
CMU WALL
STRUCTURE
UNDERSIDE OF
FINISH FLOOR
SEE STRUCT DWGS
CONC. CURB
STUDS @ 16" O.C.
BOTH SIDES OF 6" MET
5/8" GYPSUM BOARD ON
TRUSSES OR STRUCT. CEILING
EXIST ADJACENT ROOF
STRUCT. DWGS SECURE TO
METAL STUDS BRACING, SEE
CEILING
(WHERE OCCURS)
STRUCTURAL CEILING
WHERE OCCURS
8" CMU WALL
FULL HEIGHT
GYPSUM BOARD WALL
5" METAL STUD
COUNTER FLASHING
SHEET METAL
SEALANT
W/ EPOXY PAINT
CMU WALL
W/ EPOXY PAINT
CMU WALL
A-505
B3
PARTITION TYPES
SCALE: NTS
C3
CONC SPLASH BLOCK ISOMETRIC DETAIL
SCALE: 1 1/2" = 1'-0"
C1
SCALE: 1 1/2" = 1'-0"
GUTTER DETAIL
C2
GUTTER DOWNSPOUT DETAIL
SCALE: 6" = 1'-0"
A1
SCALE: NTS
EXHAUST WALL CAP
A2
EAVE WITH GUTTER DETAIL
SCALE: 3" = 1' - 0"
A4
SCALE: 3" = 1' - 0"
TYPCIAL CONDUIT PENETRATION DETAIL
B U
IL
D
IN
G
D E
T A
IL
S
G E
N E
R A
L I
N F
O A
N D
D E
T A
IL
L
IC
IT
A
T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
F
IL
E N
U M
B E
R
S I Z
E
S U
B M
IT
T
E D
B Y
P L
O T
S C
A L
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T
N O
D A
T E
A P
P R
®of Engineers
US Army Corps
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
A N
S I
D R
H J G
-T
IT
L B
K .d g n
IS
S
U E
D A
T E
P A
C
IF
IC
O
C E
A N
H O
N O
L U
L U
H
A W
A
II
B O
W E
R S
A N
D K
U B
O T
A
M A
N A
G E
M E
N T
-4
A
K O
K I
S T
R E
E T
W A
IP
A
H U
H
I
W A
-1 -D
-0
JL
/H
D
J L
/F L
H D
JL
/H
D
A S
N O
T E
D
W A
-1 -D
-0
D
C
A
B
1 2 3 4 5
SHEET ID
IS
L
A N
D O
F H
A W
A
II
H
A W
A
II
P O
H A
K U
L O
A T
R A
IN
IN
G A
R E
A
T R
A
IN
IN
G
C O
M P
L E
X
B A
R R
A C
K S
P
H
F Y
M C
A P
N
O P
E R
A T
IO
N
A L
R E
A D
IN
E
S S
/2 /8
/2
/8
ALUMINUM
HEADRAIL
(S T
D
PLASTER
SHOE
(A .F
.F
FRONT ELEVATION
FIXED
SHOWER SEAT
SOLIDPLASTIC
SHOWER/
DRESSING
COMPARTMENTS
(SSC-1)
PREFABRICATED
TERRAZO SHOWER BASE.
BASIS OF DESIGN:
ACORN TERAZZO-WARE
OR APPROVED EQUAL
(A .F
.F
CONTINUOUS
BRACKETS
S H
O W
E R
C O
R N
E B
R A
C K
E T
S
T
B
C
K W
A L
L S
P
IL
A
S T
E R
/P A
N
L
C
N N
C
O N
T B
R A
C K
E T
S
/2
H
IG
H
C O
N T
IN
U
O U
S A
L U
M
36" BASE
COMPARTMENT
SHOWER
COMPARTMENT
DRESSING
SEAL ALL
JOINTS
BETWEEN
PARTITIONS
SEALANT AT
RABBET JOINT7"3'-3"
CURTAIN AND
CURTAIN ROD
SECTION
6'-10"
SOLID PLASTIC
SHOWER/DRESSING
COMPARTMENTS
(SSC-1)
FIXED
SHOWER
SEAT
PRE FABRICATED
TERRAZO SHOWER BASE.
BASIS OF DESIGN:
ACORN TERAZZO-WARE
OR APPROVED EQUAL
A1
SHOWER & DRESSING COMPARTMENT DETAIL
AT CONC WALLS
OC, PROVIDE EXP SHIELDS
1/4" SST FASTENERS @ 16"
20 GA SST FLASHING
CAP FLASHING
SEALANT
SST CORNER JOINT
16 GA SST ANGLE
SHOWER PANEL
SCALE: 3" = 1'-0"
#8 SST SCREWS @ 6" OC
CAP FLASHING
20 GA SST
JOINT
SST CORNER
PANEL
SHOWER
END WALL - BACK CHASE PLAN -BACK
END WALL - FRONT CHASE PLAN -FRONT END WALL - CORNER
CAP
SST TOP
JOINT
SST CORNER
SEAMING
SHOWER
RECEPTOR
SHOWER
RECEPTOR
SHOWER
SST CORNER JOINT
SEALANT
SHOWER RECEPTOR
RECEPTOR BASE
SST CORNER JOINT
SHOWER PANEL
SHOWER PANEL
W/ANCHORS
W/#12 SST SCREWS
STRIP, FASTEN TO WALL
20 GA SST SEAMING
BASE
RECEPTOR
SHOWER PANEL
PANEL
SHOWER
JOINT
SST CORNER
PANEL, FASTEN TO WALL
SHOWER SEAMING
BENCH
SHOWER PANEL
PANEL, FASTEN TO WALL
SHOWER SEAMING
BENCH
SHOWER PANEL
SECTION - BACK WALL AT TOP SECTION - CHASE AT TOP
ELEVATION AT TOP
SECTION - CHASE
PANEL
SEAMING
SHOWER
SECTION - CHASE AT BASE ELEVATION - CHASE BASESECTION - BACK WALL AT BASE
BRACKET
CONTINUOUS
0 2'
SCALE: 3" = 1'-0"
1'
M
IS
C B
U
IL
D
IN
G D
E T
A
IL
S
A-506
3"
7"
L
L
L
L
DIMENSIONS SHOWN ARE TO ROUGH OPENING, TYP.
PREFINSIHED ALUMINUM STORM-RESISTANT LOUVERS, TYP.
2'-8"
3'-4" 1'-4" 2'-0"
D
D
1 3/4" THICK, HOLLOW METAL,
FLUSH PANEL METAL DOOR.
D
DIMENSIONS SHOWN ARE TO ROUGH OPENING, TYP.
1 3/4" THICK, HOLLOW METAL,
FLUSH PANEL METAL DOOR.
1 3/4" THICK, HOLLOW METAL,
FLUSH PANEL METAL DOOR.
6'-4"
UTILITY CLOSET (10)
5' 0" AT BLDG. 133
6'-0"3'-0"
3'-4"
3'-10"
3'-6"
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
F
IL
E N
U M
B E
R
S I Z
E
S U
B M
IT
T
E D
B Y
P L
O T
S C
A L
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T
N O
D A
T E
A P
P R
®of Engineers
US Army Corps
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
A N
S I
D R
H J G
-T
IT
L B
K .d g n
IS
S
U E
D A
T E
P A
C
IF
IC
O
C E
A N
H O
N O
L U
L U
H
A W
A
II
B O
W E
R S
A N
D K
U B
O T
A
M A
N A
G E
M E
N T
-4
A
K O
K I
S T
R E
E T
W A
IP
A
H U
H
I
W A
-1 -D
-0
JL
/H
D
J L
/F L
H D
JL
/H
D
A S
N O
T E
D
W A
-1 -D
-0
D
C
A
B
1 2 3 4 5
SHEET ID
IS
L
A N
D O
F H
A W
A
II
H
A W
A
II
P O
H A
K U
L O
A T
R A
IN
IN
G A
R E
A
T R
A
IN
IN
G
C O
M P
L E
X
B A
R R
A C
K S
P
H
F Y
M C
A P
N
O P
E R
A T
IO
N
A L
R E
A D
IN
E
S S
/2 /8
/2
/8
W
W
W
W
DIMENSIONS SHOWN ARE TO ROUGH OPENING, TYP.
PREFINSIHED ALUMINUM SLIDING WINDOWS, TYP.
GLASS
LOW EMISSIVITY INSULATING
NO. 4 SURFACE.
TRANSLUCENT FILM ON
AS SPECIFIED WITH
1/4" LAMINATED GLASS
GLASS
LOW EMISSIVITY INSULATING
GLASS
LOW EMISSIVITY INSULATING
NO. 4 SURFACE.
TRANSLUCENT FILM ON
AS SPECIFIED WITH
1/4" LAMINATED GLASS
GLASS
LOW EMISSIVITY INSULATING
8'-0"
8'-0" 4'-0"
SILL
BELOW
4" CMU
SILL
4" PRECAST
4'-0"
SILL
4" PRECAST
SILL
BELOW
4" CMU
SILL
BELOW
4" CMU
SILL
4" PRECAST
SILL
4" PRECAST
SILL
BELOW
4" CMU
EACH SIDE
CONT. SEALANT
DOOR
BEYOND
FRAME
OVER CMU WALL
PLASTER FINISH
SKIM COAT
AS SPECIFIED
SET IN SEALANT
THRESHOLD
METAL FRAME
PAINTED
OVER CMU WALL
ANCHORS, TYP.
W/ MASONRY
METAL FRAME
PAINTED
DOOR
PERPENDICULAR WALL
TO THE ADJACENT
TYP ON THE HINGE SIDE
BITUMINOUS MATERIAL
WITH CORROSION-INHIBITING
INSIDE FACE OF FRAMES
SOLID GROUTED. COAT
DOOR FRAMES SHALL BE
NOTE:
D O
O R
S
IZ
E
4"
DOOR SIZE8" 2"
D O
O R
S
IZ
E
EQ.
EQ.
DOOR
m a x
SCREEN
REMOVABLE
WINDOW
EACH SIDE
CONT. SEALANT
SCREEN
REMOVABLE
WINDOW
SILL
CONCRETE
PRECAST
OVER CMU WALL
4" CMU UNDER
WINDOW SILL
EACH SIDE
CONT. SEALANT
FRAME
ALUMINUM
WINDOW
R .O
R .O
4"
R.O.
4"
FRAME
ALUMINUM
OVER CMU WALL
OVER CMU WALL
CONCRETE SILL
PRECAST
DRIP EDGE
SCREEN
REMOVABLE
WINDOW
EACH SIDE
CONT. SEALANT
EACH SIDE
SEALANT
CONT.
OVER CMU WALL
OVER CMU WALL
LOUVER MFR
CLIP ANGLE BY
SCREEN
BIRD/INSECT
LOUVER MFR
CLIP ANGLE BY
SCREEN
BIRD/INSECT
METAL LOUVER
SCREEN
BIRD/INSECT
LOUVER MFR
CLIP ANGLE BY
LOUVER MFR
SEALANT BY
SET ON BED OF
METAL SILL PAN
OVER CMU WALL
3 1/8"1/2"
M .O
/8
/2
M.O.
3 1/8"4"
1/2"
M .O
4"
METAL LOUVER
D
QTY MARK #
D
D
THK COMMENT
BLDG. 121 - LAUNDRY STOR INT.1
BLDG. 140, 149 - ADMIN4 4
2 9
147, 148 - BARRACKS - LARGE
BLDG. 135, 136, 137, 138, 139, 144, 145, 146, 20 7
1 3/4"
1 3/4"
1 3/4"
1 3/4"
1 3/4"
1 3/4"
HMD
HMD
HMD
HMD
HMD
HMD
DRSET
HW
FR
HMF
HMF
HMF
HMF
HMF
HMF
MODE
SGL
SGL
SGL
SGL
SGL
PR
DR INTO LAUNDRY
DR INTO CHASE SPACE
FINISH
PT-2
PT-2
PT-2
PT-2
PT-2
PT-2
BLDG. 131/131A, 142/142A- SHOWER/LATRINE 3 SGL 1 3/4" HMD HMF PT-2
3 SGL 1 3/4" HMD HMF PT-2BLDG. 133 - LATRINE ONLY
BLDG. 133 LATRINE1 10 1 3/4" HMD HMFPR DR INTO UTILITY CLOSETPT-2
MAIN ENTRANCES
MAIN ENTRANCES
1 1 1 3/4" HMD HMFSGL DR INTO STORAGEPT-2
DR INTO STORAGE ROOM
BLDG. 121 - LAUNDRY STOR INT.
BLDG. 121 - LAUNDRY STOR INT.
BLDG. 131/131A, 142/142A- SHOWER/LATRINE
BLDG. 131/131A, 142/142A- SHOWER/LATRINE
DOOR BETWEEN LAUNDRY & STOR
SCALE: 1/4" = 1'-0"
B1
WINDOW TYPES
SCALE: 1/4" = 1'-0"
A1
LOUVER TYPES
SCALE: 1/4" = 1'-0"
C1
DOOR TYPES
SCALE: 3" = 1'-0"
C3
DOOR HEAD
SCALE: 3" = 1'-0"
C4
DOOR JAMB
SCALE: 3" = 1'-0"
C5
DOOR THRESHOLD
SCALE: 3" = 1'-0"
B3
WINDOW HEAD
SCALE: 3" = 1'-0"
B4
WINDOW JAMB
SCALE: 3" = 1'-0"
B5
WINDOW SILL
SCALE: 3" = 1'-0"
A3
LOUVER HEAD
SCALE: 3" = 1'-0"
A4
LOUVER JAMB
SCALE: 3" = 1'-0"
A5
LOUVER SILL
D E
T A
IL
S
D O
O R
W
IN
D
O W
A
N D
S
IG
N A
G E
G E
N
IN
F
O A
N D
D E
T A
IL
A-510
B
C E
Z A
R
G E
O R
G E G
U T
IE
R R
E Z J
R
G
G U
T
IE
R R
E Z
K S
H
IM
O K
A W
A
S T
R U
C T
U R
A L G
E N
E R
A L N
O T
E S
R H
J S -0
.d g n
S-001
H
NO. 12107-S
WA
ZE
R J
U.
A.SIA I,
R O
E
G E
ENGINEER
PROFESSIONAL
G LICENSED
EI
RR
T.O
UG
4.30.20
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
D A
T E
A P
P R
®of Engineers
US Army Corps
A N
S I
D
IS
S
U E D
A T
E
A S N
O T
E D
SHEET ID
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
P A
C
IF
IC
O
C E
A N
H O
N O
L U
L U
H A
W A
II
B O
W E
R S A
N D K
U B
O T
A
M A
N A
G E
M E
N T
-4
A
K O
K I S
T R
E E
T
W A
IP
A H
U
H I
IS
L
A N
D O
F H
A W
A
II
H A
W A
II
P O
H A
K U
L O
A T
R A
IN
IN
G A
R E
A
T R
A
IN
IN
G C
O M
P L E
X
B A
R R
A C
K S P
H
F Y M
C A P
N O
P E
R A
T
IO
N A
L R
E A
D
IN
E S
S
/2 /8
W
A -1
-D -0
W
A -1
-D -0
/2 /8
AREA OF WORK AS NECESSARY.
DRAWINGS. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING DIMENSIONS IN
ALL EXISTING BUILDING DIMENSIONS ARE BASED ON AVAILABLE EXISTING 5.
CONCRETE AND CMU WALLS AND SLABS.
NEW PIPES AND CONDUITS SHALL NOT BE EMBEDDED IN EXISTING 4.
NEW OPENINGS IN EXISTING SLABS AND WALLS SHALL NOT BE OVERCUT.3.
TO THE CONTRACTING OFFICERS'S ATTENTION PRIOR TO STARTING WORK.
STARTING WORK. ANY DISCREPANCIES WITH DRAWINGS SHALL BE BROUGHT
DIMENSIONS SHALL BE VERIFIED BY CONTRACTOR IN FIELD PRIOR TO
SEE ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS. ALL EXISTING 2.
DEMOLITION WORK.
CONTRACTOR SHALL PROVIDE ADEQUATE SHORING AND BRACING FOR ALL 1.
DEMOLITION NOTES
REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION.4.
FIBER WRAP SYSTEM SHALL CONFORM TO ACI 440.2R.3.
AS A MINIMUM.
LOCATIONS AND FORCE DEMANDS THAT FIBER WRAP SYSTEM MUST RESIST
STRUCTURAL DRAWINGS BY NAGAMINE OKAWA ENGINEERS INC. PROVIDE 2.
FOR REVIEW AND COMMENT.
WRAP DESIGN ENGINEER SHALL BE PROVIDED TO CONTRACTING OFFICER
CALCULATIONS AND SHOP DRAWINGS STAMPED AND SIGNED BY FIBER
AND SHALL BE DESIGNED BY A LICENSED STRUCTURAL ENGINEER.
FIBER WRAP STRENGTHENING SHALL BE PROVIDED BY THE CONTRACTOR 1.
FIBER WRAP STRENGTHENING
SUSPENDED CEILINGS, MECHANICAL DUCTS, PIPING, ETC.
METAL DECKING WITHOUT TOPPING SHALL NOT BE USED TO SUPPORT 12.
ALL WELDS SHALL HAVE TOUCH-UP.
MANUFACTURER'S RECOMMENDATIONS. UPON COMPLETION OF ERECTION,
INDICATED ON THE DRAWINGS AND IN ACCORDANCE WITH
BE ATTACHED TO ALL SUPPORTING STEEL MEMBERS BY WELDING AS
MINIMUM BEARING OF DECKING ON SUPPORTS SHALL BE 2". SHEETS SHALL 11.
SHALL SPAN OVER THREE OR MORE SUPPORTS.
PROTECTIVE COATING OF ZINC (G60). SEE SPECIFICATIONS. DECK UNITS
CONFORMING TO ASTM A446, GRADE A. THE STEEL SHALL HAVE A METAL
STEEL SHEETS HAVING A MINIMUM YIELD STRENGTH OF 33,000 PSI AND
THE DRAWINGS. DECKING AND ALL ACCESSORIES SHALL BE FORMED FROM
THE STEEL DECKING SHALL BE OF THE TYPE AND GAUGE AS CALLED FOR ON 10.
5,000 PSI. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION.
CONCRETE WALLS, ETC., SHALL BE NON-SHRINK, NON-STAINING, WITH f'c =
ALL GROUT (OR DRYPACK) BELOW BASE PLATES, BEAMS BEARING ON 9.
COATED WITH TWO COATS OF ZINC RICH PRIMER.
ASTM A123 OR A153. ALL WELDS AFTER HOT DIP GALVANIZING SHALL BE
HOT DIP GALVANIZED STEEL REFERENCED ON PLAN SHALL CONFORM TO 8.
SPECIFICATIONS.
CODE AWS D1.1-04 OF THE AMERICAN WELDING SOCIETY; SEE
ALL WELDS SHALL BE IN CONFORMITY WITH THE STRUCTURAL WELDING 7.
MASONRY SHALL BE CLEAN AND LEFT UNPAINTED.
ALL STRUCTURAL STEEL SURFACES THAT ARE ENCASED IN CONCRETE OR 6.
SIZE OF BOLT USED, UNLESS OTHERWISE NOTED.
BOLT HOLES IN STEEL SHALL BE 1/16" LARGER DIAMETER THAN NOMINAL 5.
REVIEW BEFORE FABRICATION.
ALL STRUCTURAL STEEL RESPECTIVELY, FOR CONTRACTING OFFICER'S
THE STRUCTURAL STEEL FABRICATOR SHALL FURNISH SHOP DRAWINGS OF 4.
GALVANIZED.
RODS EPOXY EMBEDDED SHALL CONFORM TO ASTM A36 AND BE HOT DIP
CONFORMING TO ASTM A325 OR A490. UNLESS OTHERWISE NOTED, ANCHOR
UNLESS OTHERWISE NOTED. USE ALTERNATIVE DESIGN FASTENER
ALL BOLTS SHALL CONFORM TO ASTM A325N HIGH STRENGTH BOLTS, 3.
= A500, GRADE BTUBES
= A500, GRADE BPIPES
= A36PLATES, MISC. STEEL
CHANNELS, ANGLES, TEES,
= A992, GRADE 50WIDE FLANGES
DESIGNATIONS:
STRUCTURAL STEEL SECTIONS SHALL CONFORM TO THE FOLLOWING ASTM 2.
FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS."
ACCORDANCE WITH THE "AISC SPECIFICATION FOR THE DESIGN,
STRUCTURAL STEEL SHALL BE DETAILED, FABRICATED AND ERECTED IN 1.
STRUCTURAL STEEL
STEEL" OF THE AMERICAN WELDING SOCIETY.
CONFORM TO AWS D1.4 "AWS STRUCTURAL WELDING CODE - REINFORCING
SHOWN ON THE DRAWINGS. WELDING OF REINFORCING STEEL SHALL
WELDING OF REINFORCING STEEL IS NOT PERMITTED UNLESS OTHERWISE 8.
FROM REVIEWED DRAWINGS ONLY.
CONTRACTING OFFICER'S REVIEW PRIOR TO FABRICATION. FABRICATE
CONTRACTOR SHALL SUBMIT REINFORCING BAR LAYOUTS AND DETAILS FOR 7.
MODIFIED BY THE PROJECT DRAWINGS AND SPECIFICATIONS.
CONFORMANCE WITH THE "ACI DETAILING MANUAL - 2004" (SP-66) AS
ALL REINFORCING STEEL SHALL BE DETAILED AND PLACED IN 6.
ALL REINFORCING BAR BENDS SHALL BE MADE COLD.5.
SECURELY TIED IN PLACE BEFORE CONCRETE IS POURED.
ANCHOR BOLTS, DOWELS AND OTHER EMBEDDED ITEMS ARE TO BE 4.
DRAWINGS.
REINFORCING SPLICES SHALL BE MADE ONLY WHERE INDICATED ON THE 3.
U.O.N.
AND SPACING OR NUMBERS AS THE VERTICAL REINFORCING RESPECTIVELY,
DOWELS BETWEEN FOOTING AND WALL SHALL BE THE SAME GRADE, SIZE 2.
REQUIREMENTS OR ASTM A706 WHERE WELDING IS REQUIRED.
REINFORCING BARS SHALL CONFORM TO ASTM A-615 GRADE 60 1.
REINFORCING STEEL
SUPPLIER.
FOR RETARDATION BY THE ADMIXTURE MANUFACTURER OR THE CONCRETE
MINUTES PER SPECIFICATIONS MAY BE INCREASED BY THE TIME SPECIFIED
IF A RETARDING ADMIXTURE IS USED, THE DISCHARGE TIME LIMIT OF 90 12.
AMPLITUDE OF 1/4".
ALL ROUGHENED SURFACES IN CONCRETE SHALL BE MADE WITH A MINIMUM 11.
SHALL NOT BE USED.
CONCRETE ADMIXTURES CONTAINING CHLORIDE OR CHLORIDE SALTS 10.
SPECIFYING CONCRETE POURS IN UPCOMING THREE WEEKS.
CONTRACTOR SHALL PROVIDE THE CONTRACTING OFFICER A SCHEDULE 9.
BEFORE USE.
ARCHITECTURAL FINISH SHALL BE APPROVED BY THE FINISH SUPPLIER
CURING COMPOUNDS USED ON CONCRETE THAT IS TO RECEIVE AN 8.
SHOWN ON THE DRAWINGS.
NOTIFY THE CONTRACTING OFFICER IN ADVANCE OF CONDITIONS NOT
CONFLICT. CORING IN CONCRETE IS NOT PERMITTED EXCEPT AS SHOWN.
CONCRETE BEFORE PLACING. DO NOT CUT ANY REINFORCING WHICH MAY
PROVIDE SLEEVES FOR PLUMBING AND ELECTRICAL OPENINGS IN 7.
SHALL BE WELL SECURED IN POSITION PRIOR TO PLACING CONCRETE.
ALL REINFORCING BARS, ANCHOR BOLTS AND OTHER CONCRETE INSERTS 6.
1" CLEAR TO REINFORCINGWALLSC.
1 1/2" CLEAR AT TOP (EXTERIOR)
1" CLEAR AT TOP (INTERIOR)SLAB ON GRADEB.
3" CLEAR TO REINFORCING AGAINST EARTH
CONCRETE DIRECTLY A.
BE AS FOLLOWS (U.O.N.):
CLEAR COVERAGE OF CONCRETE OVER OUTER REINFORCING BARS SHALL 5.
PROJECT SITE.
SHALL ACCOUNT FOR TRAVEL TIME AND TEMPERATURE CONDITIONS AT THE
OFFICER FOR REVIEW PRIOR TO CONSTRUCTION. CONCRETE MIX DESIGN
WHERE MIX IS USED. MIX DESIGN SHALL BE SUBMITTED TO CONTRACTING
CONCRETE MIX DESIGN SUBMITTAL SHALL STATE LOCATION OF STRUCTURE 4.
4,000 PSIMISC CONCRETE
3,000 PSIFOUNDATIONS, CURBS & SLAB ON GRADE
SCHEDULE OF STRUCTURAL CONCRETE 28-DAY STRENGTH AND TYPES:3.
CONTRACTING OFFICER FOR REVIEW.
QUALIFIED TESTING LABORATORY AND SHALL BE SUBMITTED TO THE
ASTM C-150 TYPE I OR II. CONCRETE MIXES SHALL BE DESIGNED BY A
HARD ROCK TYPE (150#/CU. FT.) PORTLAND CEMENT SHALL CONFORM TO
ALL CONCRETE UNLESS OTHERWISE NOTED SHALL BE NORMAL WEIGHT 2.
CONCRETE WORK SHALL BE IN ACCORDANCE WITH ACI 301, UON.1.
CONCRETE
UNTIL PERMANENT STRUCTURAL FRAMING IS INSTALLED.
CONTRACTOR SHALL PROVIDE BRACING/SHORING OF CMU CONSTRUCTION 11.
TYPE.
FOR SURFACE TEXTURE AND HEIGHT OF UNITS, LAYING PATTERN AND JOINT
CONVENTIONAL RUNNING BOND. REFER TO ARCHITECTURAL DRAWINGS
UNLESS NOTED OTHERWISE, ALL WALLS SHALL BE CONSTRUCTED IN 10.
SETTING BLOCKS.
CONCRETE SURFACES SHALL BE CLEANED OF ALL LAITANCE PRIOR TO 9.
VERT. BARS WITH POSITIONERS AT 8'-0" MAX.
SET TO ALIGN WITH CORES CONTAINING REINFORCING STEEL. SECURE
CELL SHALL BE IN VERTICAL ALIGNMENT. DOWELS IN FOOTING SHALL BE 8.
PROVIDE CLEANOUT AT BASE FOR CELL CONTAINING REINFORCING.
IF BLOCK IS LAYED TO A HEIGHT EXCEEDING 5'-4" FOR EACH GROUT LIFT, 7.
GROUT SOLID ALL CELLS IN CONCRETE BLOCKS.6.
MASONRY UNITS.
PROVIDE A MINIMUM OF 1/2" GROUT BETWEEN MAIN REINFORCING AND 5.
REQUIREMENTS.
REINFORCING BARS - SEE NOTE UNDER REINFORCING STEEL FOR 4.
SEGREGATION. COMPRESSIVE STRENGTH AT 28 DAYS = 3,000 PSI.
GROUT SHALL FLOW INTO ALL JOINTS OF THE MASONRY WITHOUT 3.
ATTAIN COMPRESSIVE STRENGTH OF 1,800 PSI AT 28 DAYS.
ALL WALLS SHALL BE CONSTRUCTED WITH TYPE S MORTAR. MORTAR SHALL 2.
UNIT CONFORMING TO ASTM C 90, NORMAL WEIGHT, f'm = 1,500 PSI.
CONCRETE BLOCK SHALL BE HOLLOW LOAD-BEARING CONCRETE MASONRY 1.
CONCRETE MASONRY (CMU)
ENGINEER'S SHORING DESIGN AS REQUIRED FOR INFORMATION ONLY.
BE PROVIDED AND INSTALLED BY THE CONTRACTOR. SUBMIT STRUCTURAL
PROPERTY FREE FROM THE DAMAGE RESULTING FROM THE WORK, SHALL
THE EXCAVATIONS, EARTH BANKS AND ADJACENT STRUCTURES AND
SHORING, SHEETING, CRIBBING AND LAGGING, AS REQUIRED TO PRESERVE 13.
TO EM 385-1-1 SAFETY AND HEALTH REQUIREMENTS MANUAL.
CONTRACTOR AGAINST DANGER TO LIFE, LIMB AND PROPERTY. CONFORM
ALL EXCAVATIONS SHALL BE PROTECTED AND GUARDED BY THE 12.
BACKFILL MATERIAL SHALL CONSIST OF NON-EXPANSIVE GRANULAR SOIL.11.
DENSITY AS DETERMINED BY ASTM D 1557.
COMPACTION EQUAL TO OR BETTER THAN 95 PERCENT OF MAXIMUM
WHICH SHALL BE COMPACTED AT OPTIMUM MOISTURE CONTENT TO
FILL SHALL BE PLACED IN SUCCESSIVE LOOSE LAYERS 8 INCHES DEEP 10.
LAYERS BY PNEUMATIC TAMPER INTO A DENSE MASS.
BACKFILL AROUND FOOTINGS AND FOUNDATIONS SHALL BE COMPACTED IN 9.
ASTM C33, NO. 67 GRADATION.
USING A VIBRATORY COMPACTOR. CUSHION LAYER SHALL CONFORM TO
CUSHION LAYER OF CLEAN GRAVEL AND COMPACT TO A LEVEL SURFACE
UNLESS OTHERWISE NOTED, FOR FILL UNDER SLAB ON GRADE, USE A 4 INCH 8.
PERCENT RELATIVE COMPACTION.
ABOVE THE OPTIMUM MOISTURE CONTENT AND COMPACTED TO AT LEAST 95
EXCEEDING 8 INCHES IN LOOSE THICKNESS, MOISTURE-CONDITIONED TO
STRUCTURAL FILL MATERIALS SHOULD BE PLACED IN LEVEL LIFTS NOT 7.
A WELL-GRADED MATERIAL.
TO PROVIDE THE REQUIRED GRADATION AND PARTICLE SIZES TO DEVELOP
LARGE-SIZED ROCK FRAGMENTS OR BOULDERS SHOULD BE CONSIDERED
TO PRODUCE A WELL-GRADED MATERIAL, OFF-SITE CRUSHING OF
IF THE EXCAVATED ON-SITE MATERIALS DO NOT CONTAIN SUFFICIENT FINES 6.
REQUIREMENTS.
PROCESSED TO MEET MAXIMUM PARTICLE SIZE AND GRADATION
STRUCTURAL FILL MATERIALS, PROVIDED THAT THE MATERIALS ARE
EXCAVATED ON-SITE MATERIALS MAY BE RE-USED AS A SOURCE OF
PREVENT THE OCCURRENCE OF VOIDS IN THE COMPACTED MASS. THE
MATERIALS 1-1/2 INCHES IN LARGEST DIMENSION WITH SUFFICIENT FINES TO
STRUCTURAL FILL MATERIALS SHALL CONSIST OF WELL-GRADE GRANULAR 5.
STRUCTURAL FILL AS REQUIRED.
MATERIAL, INCLUDING ASH AND ORGANICS AND REPLACE WITH COMPACTED
CONTRACTOR'S GEOTECHNICAL ENGINEER. REMOVE UNSATISFACTORY
SHALL BE NOTIFIED. FOOTINGS MAY BE ALTERED AS REQUIRED BY THE
EXPECTED CONDITIONS, THE CONTRACTOR'S GEOTECHNICAL ENGINEER
SOIL ENCOUNTERED AT THESE DEPTHS APPEAR UNSTABLE AND VARY FROM
FOOTINGS SHALL BE PLACED ON UNDISTURBED EXISTING SOIL. SHOULD 4.
ARE FOUND AND GROUTING IS REQUIRED.
PSI). CONTRACTOR SHALL PROVIDE UNIT PRICE PER CUBIC YARD IF VOIDS
FOOTING). IF VOIDS ARE FOUND, FILL VOID WITH LEAN CONCRETE (f'c = 1,500
GREATER (FOR EXAMPLE, MINIMUM 24'-0" DEEP PROBE AT 12'-0" WIDE
MINIMUM DEPTH OF 2 TIMES THE FOOTING WIDTH OR 10 FEET WHICHEVER IS
FOOTING AND EVERY 20 FEET OF WALL FOOTING. PROBE SHALL EXTEND A
PROVIDE A MINIMUM OF ONE PROBE FOR VOIDS BELOW EACH COLUMN
VOIDS THAT MAY BE ENCOUNTERED DURING FOUNDATION CONSTRUCTION.
SPECIAL CONSIDERATION SHALL BE GIVEN TO LAVA TUBES AND OTHER
= 0.25COEFFICIENT OF FRICTION
PCF= 150LATERAL PASSIVE PRESSURE
= 75 PCF (ASSUMED)AT-REST PRESSURE
= 50 PCF (ASSUMED)ACTIVE PRESSURE
AS WIND OR SEISMIC (ASSUMED)
SHORT DURATION LOADS SUCH
= 2,000 PSF W/ 1/3 INCREASE FOR ALLOWABLE BEARING PRESSURE
FOUNDATION DESIGN PARAMETERS:3.
CONTRACTOR SHALL HIRE AND PAY FOR A GEOTECHNICAL ENGINEER.2.
CODE, TABLE 1806.2, ITEM 4.
THE FOUNDATION DESIGN IS BASED ON THE 2015 INTERNATIONAL BUILDING 1.
FOUNDATION
SHALL APPLY.
DRAWINGS AND SPECIFICATIONS, THE MORE STRINGENT REQUIREMENT
SHOULD THERE BE CONFLICTS IN THE REQUIREMENTS BETWEEN THE 13.
SUBMITTED TO CONTRACTING OFFICER WITHIN 72 HOURS.
SPECIAL INSPECTION. ALL SPECIAL INSPECTION REPORTS SHALL BE
LEAST 2 DAYS IN ADVANCE FOR WORK TO BE PERFORMED REQUIRING
SAFETY ON SITE. CONTRACTOR SHALL NOTIFY SPECIAL INSPECTOR AT
ACCORDANCE WITH THE DRAWINGS AND SPECIFICATIONS AND TO PROVIDE
CONTRACTOR OF HIS RESPONSIBILITIES TO COMPLETE THE PROJECT IN
AND TESTING SERVICES. SPECIAL INSPECTION SHALL NOT RELIEVE THE
CONTRACTOR SHALL HIRE AND PAY FOR THIRD-PARTY SPECIAL INSPECTION
REQUIREDUPLIFT TIESG.
REQUIREDMASONRY (LEVEL B)F.
REQUIREDEPOXY EMBEDSE.
REQUIREDANCHOR BOLTSD.
REQUIREDHIGH-STRENGTH BOLTSC.
REQUIREDREINFORCING STEEL B.
REQUIREDCONCRETE A.
STRUCTURAL DRAWINGS.
GOVERNING PORTIONS OF THE STRUCTURAL WORK SHOWN IN THE
PROVISIONS OF SECTION 1704 OF THE 2015 INTERNATIONAL BUILDING CODE
ALL SPECIAL INSPECTION SHALL BE DONE PER IBC SPECIAL INSPECTIONS
STRUCTURAL SPECIAL INSPECTION REQUIREMENTS:12.
= BALANCED DESIGNDESIGN METHOD
= 6 DEGREESEND ROTATION LIMIT
= 7DUCTILITY RATIO LIMIT
4-010-01
PER TABLE 2-1 OF UFC
ACCORDING TO ASTM F1642
= “VERY LOW HAZARD” GLASS PERFORMANCE RATING
= 55.4 PSI-MSECFULLY REFLECTED POSITIVE IMPULSE
= 15.8 PSIPEAK REFLECTED POSITIVE PRESSURE
THAT IS NOT CONTROLLED
PARAMETERS APPLYING TO WINDOWS 50 FEET OR MORE FROM PARKING
WINDOW DYNAMIC BLAST PARAMETERS
= D SEISMIC DESIGN CATEGORY
= 0.60g D1
S = 1.00g
DS
S
= DSITE CLASS
= 0.60g
S
= 1.50g S
S
II =RISK CATEGORY
= 1.00 IMPORTANCE FACTOR
D. SEISMIC (ASCE 7-10)
= 1.5
ZT
K
= CWIND EXPOSURE
II= RISK CATEGORY
= 130 MPHBASIC WIND SPEED
C. WIND (ASCE 7-10)
FLOOR LOADS TYPICALLY SUPPORTED BY SLAB ON GRADE.
ALL LIVE LOADS REDUCIBLE, UON
= 20 PSFROOF (FLAT TO LESS THAN 4:12)
= 100 PSFLAUNDRY
= 100 PSFLATRINE
= 100 PSFSHOWER
= 100 PSFGP ADMIN (SMALL)
= 100 PSFBARRACKS (LARGE)
B. LIVE LOADS
UFC 3-301-01A. GENERAL STRUCTURAL DESIGN
DESIGN CRITERIA11.
FLOORS OR ROOF.
CONSTRUCTION MATERIALS SHALL BE SPREAD OUT IF PLACED ON FRAMED 10.
STRUCTURAL MEMBERS.
NOT SHOWN ON THE STRUCTURAL DRAWINGS, BUT WHICH ARE LOCATED IN
DRAWINGS BY OTHERS SHOW OPENINGS, POCKETS, ETC., LARGER THAN 6"
STRUCTURAL DRAWINGS. NOTIFY THE CONTRACTING OFFICER WHEN
SLABS, BEAMS, WALLS, ETC., UNLESS SPECIFICALLY DETAILED ON THE
OPENINGS, POCKETS, ETC. LARGER THAN 6" SHALL NOT BE PLACED IN
CONCRETE OR OTHERWISE INCORPORATED IN STRUCTURAL WORK
SLEEVES, ELECTRICAL CONDUITS AND OTHER ITEMS TO BE EMBEDDED IN
LOCATION OF ALL OPENINGS REQUIRED FOR DUCTS, PIPES AND ALL PIPE
SEE MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS FOR SIZE AND 9.
AND WALL OPENINGS, FLOOR FINISHES, ETC.
SEE ARCHITECTURAL DRAWINGS FOR SIZE AND LOCATION OF ALL FLOOR 8.
SHOP DRAWINGS WILL BE REJECTED.
PHOTOCOPIES OR DUPLICATES OF CONTRACT DOCUMENTS SUBMITTED AS
TO THE CONTRACTING OFFICER FOR REVIEW PRIOR TO FABRICATION.
SHOP DRAWINGS REQUIRED BY THE SPECIFICATIONS SHALL BE SUBMITTED 7.
DIMENSIONS.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING ALL 6.
GENERAL NOTES AND TYPICAL DETAILS.
NOTES AND DETAILS ON DRAWINGS SHALL TAKE PRECEDENCE OVER 5.
PROCEEDING WITH THE WORK.
ATTENTION OF THE CONTRACTING OFFICER AND BE RESOLVED BEFORE
EXISTING STRUCTURES. ALL DISCREPANCIES SHALL BE CALLED TO THE
THE WORK OF ALL TRADES AND SHALL CHECK ALL DIMENSIONS INCLUDING
THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR COORDINATING 4.
PROPERTY AND UTILITIES.
PROCEDURES INCLUDING LAGGING, SHORING AND PROTECTION OF
THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL EXCAVATION 3.
RESPONSIBILITIES.
NOR RELIEVE THE CONTRACTOR OF HIS/HER OBLIGATIONS, DUTIES AND
GOVERNMENT'S A/E SHALL NOT INCLUDE INSPECTION OF THE ABOVE ITEMS
OBSERVATION VISITS TO THE SITE BY THE CONTRACTING OFFICER AND
STRUCTURAL ENGINEER HIRED AND PAID FOR BY THE CONTRACTOR.
SHORING AND BRACING SYSTEMS SHALL BE DESIGNED BY A LICENSED
DUE TO CONSTRUCTION EQUIPMENT, WIND AND SEISMIC LOADING. ALL
SHALL INCLUDE, BUT NOT BE LIMITED TO BRACING, SHORING FOR LOADS
PROTECT THE STRUCTURE DURING CONSTRUCTION. SUCH MEASURES
SHALL BE RESPONSIBLE FOR AND PROVIDE ALL MEASURES NECESSARY TO
DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR
THE STRUCTURAL DRAWINGS REPRESENT THE FINISHED STRUCTURE AND 2.
AND SPECIFICATIONS.
ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE DRAWINGS 1.
GENERAL
AREA OF WORK AS NECESSARY.
DRAWINGS. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING DIMENSIONS IN
ALL EXISTING BUILDING DIMENSIONS ARE BASED ON AVAILABLE EXISTING 5.
CONCRETE AND CMU WALLS AND SLABS.
NEW PIPES AND CONDUITS SHALL NOT BE EMBEDDED IN EXISTING 4.
NEW OPENINGS IN EXISTING SLABS AND WALLS SHALL NOT BE OVERCUT.3.
TO THE CONTRACTING OFFICERS'S ATTENTION PRIOR TO STARTING WORK.
STARTING WORK. ANY DISCREPANCIES WITH DRAWINGS SHALL BE BROUGHT
DIMENSIONS SHALL BE VERIFIED BY CONTRACTOR IN FIELD PRIOR TO
SEE ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS. ALL EXISTING 2.
DEMOLITION WORK.
CONTRACTOR SHALL PROVIDE ADEQUATE SHORING AND BRACING FOR ALL 1.
DEMOLITION NOTES
REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION.4.
FIBER WRAP SYSTEM SHALL CONFORM TO ACI 440.2R.3.
AS A MINIMUM.
LOCATIONS AND FORCE DEMANDS THAT FIBER WRAP SYSTEM MUST RESIST
STRUCTURAL DRAWINGS BY NAGAMINE OKAWA ENGINEERS INC. PROVIDE 2.
FOR REVIEW AND COMMENT.
WRAP DESIGN ENGINEER SHALL BE PROVIDED TO CONTRACTING OFFICER
CALCULATIONS AND SHOP DRAWINGS STAMPED AND SIGNED BY FIBER
AND SHALL BE DESIGNED BY A LICENSED STRUCTURAL ENGINEER.
FIBER WRAP STRENGTHENING SHALL BE PROVIDED BY THE CONTRACTOR 1.
FIBER WRAP STRENGTHENING
SUSPENDED CEILINGS, MECHANICAL DUCTS, PIPING, ETC.
METAL DECKING WITHOUT TOPPING SHALL NOT BE USED TO SUPPORT 12.
ALL WELDS SHALL HAVE TOUCH-UP.
MANUFACTURER'S RECOMMENDATIONS. UPON COMPLETION OF ERECTION,
INDICATED ON THE DRAWINGS AND IN ACCORDANCE WITH
BE ATTACHED TO ALL SUPPORTING STEEL MEMBERS BY WELDING AS
MINIMUM BEARING OF DECKING ON SUPPORTS SHALL BE 2". SHEETS SHALL 11.
SHALL SPAN OVER THREE OR MORE SUPPORTS.
PROTECTIVE COATING OF ZINC (G60). SEE SPECIFICATIONS. DECK UNITS
CONFORMING TO ASTM A446, GRADE A. THE STEEL SHALL HAVE A METAL
STEEL SHEETS HAVING A MINIMUM YIELD STRENGTH OF 33,000 PSI AND
THE DRAWINGS. DECKING AND ALL ACCESSORIES SHALL BE FORMED FROM
THE STEEL DECKING SHALL BE OF THE TYPE AND GAUGE AS CALLED FOR ON 10.
5,000 PSI. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION.
CONCRETE WALLS, ETC., SHALL BE NON-SHRINK, NON-STAINING, WITH f'c =
ALL GROUT (OR DRYPACK) BELOW BASE PLATES, BEAMS BEARING ON 9.
COATED WITH TWO COATS OF ZINC RICH PRIMER.
ASTM A123 OR A153. ALL WELDS AFTER HOT DIP GALVANIZING SHALL BE
HOT DIP GALVANIZED STEEL REFERENCED ON PLAN SHALL CONFORM TO 8.
SPECIFICATIONS.
CODE AWS D1.1-04 OF THE AMERICAN WELDING SOCIETY; SEE
ALL WELDS SHALL BE IN CONFORMITY WITH THE STRUCTURAL WELDING 7.
MASONRY SHALL BE CLEAN AND LEFT UNPAINTED.
ALL STRUCTURAL STEEL SURFACES THAT ARE ENCASED IN CONCRETE OR 6.
SIZE OF BOLT USED, UNLESS OTHERWISE NOTED.
BOLT HOLES IN STEEL SHALL BE 1/16" LARGER DIAMETER THAN NOMINAL 5.
REVIEW BEFORE FABRICATION.
ALL STRUCTURAL STEEL RESPECTIVELY, FOR CONTRACTING OFFICER'S
THE STRUCTURAL STEEL FABRICATOR SHALL FURNISH SHOP DRAWINGS OF 4.
GALVANIZED.
RODS EPOXY EMBEDDED SHALL CONFORM TO ASTM A36 AND BE HOT DIP
CONFORMING TO ASTM A325 OR A490. UNLESS OTHERWISE NOTED, ANCHOR
UNLESS OTHERWISE NOTED. USE ALTERNATIVE DESIGN FASTENER
ALL BOLTS SHALL CONFORM TO ASTM A325N HIGH STRENGTH BOLTS, 3.
= A500, GRADE BTUBES
= A500, GRADE BPIPES
= A36PLATES, MISC. STEEL
CHANNELS, ANGLES, TEES,
= A992, GRADE 50WIDE FLANGES
DESIGNATIONS:
STRUCTURAL STEEL SECTIONS SHALL CONFORM TO THE FOLLOWING ASTM 2.
FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS."
ACCORDANCE WITH THE "AISC SPECIFICATION FOR THE DESIGN,
STRUCTURAL STEEL SHALL BE DETAILED, FABRICATED AND ERECTED IN 1.
STRUCTURAL STEEL
STEEL" OF THE AMERICAN WELDING SOCIETY.
CONFORM TO AWS D1.4 "AWS STRUCTURAL WELDING CODE - REINFORCING
SHOWN ON THE DRAWINGS. WELDING OF REINFORCING STEEL SHALL
WELDING OF REINFORCING STEEL IS NOT PERMITTED UNLESS OTHERWISE 8.
FROM REVIEWED DRAWINGS ONLY.
CONTRACTING OFFICER'S REVIEW PRIOR TO FABRICATION. FABRICATE
CONTRACTOR SHALL SUBMIT REINFORCING BAR LAYOUTS AND DETAILS FOR 7.
MODIFIED BY THE PROJECT DRAWINGS AND SPECIFICATIONS.
CONFORMANCE WITH THE "ACI DETAILING MANUAL - 2004" (SP-66) AS
ALL REINFORCING STEEL SHALL BE DETAILED AND PLACED IN 6.
ALL REINFORCING BAR BENDS SHALL BE MADE COLD.5.
SECURELY TIED IN PLACE BEFORE CONCRETE IS POURED.
ANCHOR BOLTS, DOWELS AND OTHER EMBEDDED ITEMS ARE TO BE 4.
DRAWINGS.
REINFORCING SPLICES SHALL BE MADE ONLY WHERE INDICATED ON THE 3.
U.O.N.
AND SPACING OR NUMBERS AS THE VERTICAL REINFORCING RESPECTIVELY,
DOWELS BETWEEN FOOTING AND WALL SHALL BE THE SAME GRADE, SIZE 2.
REQUIREMENTS OR ASTM A706 WHERE WELDING IS REQUIRED.
REINFORCING BARS SHALL CONFORM TO ASTM A-615 GRADE 60 1.
REINFORCING STEEL
SUPPLIER.
FOR RETARDATION BY THE ADMIXTURE MANUFACTURER OR THE CONCRETE
MINUTES PER SPECIFICATIONS MAY BE INCREASED BY THE TIME SPECIFIED
IF A RETARDING ADMIXTURE IS USED, THE DISCHARGE TIME LIMIT OF 90 12.
AMPLITUDE OF 1/4".
ALL ROUGHENED SURFACES IN CONCRETE SHALL BE MADE WITH A MINIMUM 11.
SHALL NOT BE USED.
CONCRETE ADMIXTURES CONTAINING CHLORIDE OR CHLORIDE SALTS 10.
SPECIFYING CONCRETE POURS IN UPCOMING THREE WEEKS.
CONTRACTOR SHALL PROVIDE THE CONTRACTING OFFICER A SCHEDULE 9.
BEFORE USE.
ARCHITECTURAL FINISH SHALL BE APPROVED BY THE FINISH SUPPLIER
CURING COMPOUNDS USED ON CONCRETE THAT IS TO RECEIVE AN 8.
SHOWN ON THE DRAWINGS.
NOTIFY THE CONTRACTING OFFICER IN ADVANCE OF CONDITIONS NOT
CONFLICT. CORING IN CONCRETE IS NOT PERMITTED EXCEPT AS SHOWN.
CONCRETE BEFORE PLACING. DO NOT CUT ANY REINFORCING WHICH MAY
PROVIDE SLEEVES FOR PLUMBING AND ELECTRICAL OPENINGS IN 7.
SHALL BE WELL SECURED IN POSITION PRIOR TO PLACING CONCRETE.
ALL REINFORCING BARS, ANCHOR BOLTS AND OTHER CONCRETE INSERTS 6.
1" CLEAR TO REINFORCINGWALLSC.
BE AS FOLLOWS (U.O.N.):
CLEAR COVERAGE OF CONCRETE OVER OUTER REINFORCING BARS SHALL 5.
PROJECT SITE.
SHALL ACCOUNT FOR TRAVEL TIME AND TEMPERATURE CONDITIONS AT THE
OFFICER FOR REVIEW PRIOR TO CONSTRUCTION. CONCRETE MIX DESIGN
WHERE MIX IS USED. MIX DESIGN SHALL BE SUBMITTED TO CONTRACTING
CONCRETE MIX DESIGN SUBMITTAL SHALL STATE LOCATION OF STRUCTURE 4.
4,000 PSIMISC CONCRETE
3,000 PSIFOUNDATIONS, CURBS & SLAB ON GRADE
SCHEDULE OF STRUCTURAL CONCRETE 28-DAY STRENGTH AND TYPES:3.
CONTRACTING OFFICER FOR REVIEW.
QUALIFIED TESTING LABORATORY AND SHALL BE SUBMITTED TO THE
ASTM C-150 TYPE I OR II. CONCRETE MIXES SHALL BE DESIGNED BY A
HARD ROCK TYPE (150#/CU. FT.) PORTLAND CEMENT SHALL CONFORM TO
ALL CONCRETE UNLESS OTHERWISE NOTED SHALL BE NORMAL WEIGHT 2.
CONCRETE WORK SHALL BE IN ACCORDANCE WITH ACI 301, UON.1.
CONCRETE
UNTIL PERMANENT STRUCTURAL FRAMING IS INSTALLED.
CONTRACTOR SHALL PROVIDE BRACING/SHORING OF CMU CONSTRUCTION 11.
TYPE.
FOR SURFACE TEXTURE AND HEIGHT OF UNITS, LAYING PATTERN AND JOINT
CONVENTIONAL RUNNING BOND. REFER TO ARCHITECTURAL DRAWINGS
UNLESS NOTED OTHERWISE, ALL WALLS SHALL BE CONSTRUCTED IN 10.
SETTING BLOCKS.
CONCRETE SURFACES SHALL BE CLEANED OF ALL LAITANCE PRIOR TO 9.
VERT. BARS WITH POSITIONERS AT 8'-0" MAX.
SET TO ALIGN WITH CORES CONTAINING REINFORCING STEEL. SECURE
CELL SHALL BE IN VERTICAL ALIGNMENT. DOWELS IN FOOTING SHALL BE 8.
PROVIDE CLEANOUT AT BASE FOR CELL CONTAINING REINFORCING.
IF BLOCK IS LAYED TO A HEIGHT EXCEEDING 5'-4" FOR EACH GROUT LIFT, 7.
GROUT SOLID ALL CELLS IN CONCRETE BLOCKS.6.
MASONRY UNITS.
PROVIDE A MINIMUM OF 1/2" GROUT BETWEEN MAIN REINFORCING AND 5.
REQUIREMENTS.
REINFORCING BARS - SEE NOTE UNDER REINFORCING STEEL FOR 4.
SEGREGATION. COMPRESSIVE STRENGTH AT 28 DAYS = 3,000 PSI.
GROUT SHALL FLOW INTO ALL JOINTS OF THE MASONRY WITHOUT 3.
ATTAIN COMPRESSIVE STRENGTH OF 1,800 PSI AT 28 DAYS.
ALL WALLS SHALL BE CONSTRUCTED WITH TYPE S MORTAR. MORTAR SHALL 2.
UNIT CONFORMING TO ASTM C 90, NORMAL WEIGHT, f'm = 1,500 PSI.
CONCRETE BLOCK SHALL BE HOLLOW LOAD-BEARING CONCRETE MASONRY 1.
CONCRETE MASONRY (CMU)
ENGINEER'S SHORING DESIGN AS REQUIRED FOR INFORMATION ONLY.
BE PROVIDED AND INSTALLED BY THE CONTRACTOR. SUBMIT STRUCTURAL
PROPERTY FREE FROM THE DAMAGE RESULTING FROM THE WORK, SHALL
THE EXCAVATIONS, EARTH BANKS AND ADJACENT STRUCTURES AND
SHORING, SHEETING, CRIBBING AND LAGGING, AS REQUIRED TO PRESERVE 13.
TO EM 385-1-1 SAFETY AND HEALTH REQUIREMENTS MANUAL.
CONTRACTOR AGAINST DANGER TO LIFE, LIMB AND PROPERTY. CONFORM
ALL EXCAVATIONS SHALL BE PROTECTED AND GUARDED BY THE 12.
BACKFILL MATERIAL SHALL CONSIST OF NON-EXPANSIVE GRANULAR SOIL.11.
DENSITY AS DETERMINED BY ASTM D 1557.
COMPACTION EQUAL TO OR BETTER THAN 95 PERCENT OF MAXIMUM
WHICH SHALL BE COMPACTED AT OPTIMUM MOISTURE CONTENT TO
FILL SHALL BE PLACED IN SUCCESSIVE LOOSE LAYERS 8 INCHES DEEP 10.
LAYERS BY PNEUMATIC TAMPER INTO A DENSE MASS.
BACKFILL AROUND FOOTINGS AND FOUNDATIONS SHALL BE COMPACTED IN 9.
ASTM C33, NO. 67 GRADATION.
USING A VIBRATORY COMPACTOR. CUSHION LAYER SHALL CONFORM TO
CUSHION LAYER OF CLEAN GRAVEL AND COMPACT TO A LEVEL SURFACE
UNLESS OTHERWISE NOTED, FOR FILL UNDER SLAB ON GRADE, USE A 4 INCH 8.
PERCENT RELATIVE COMPACTION.
ABOVE THE OPTIMUM MOISTURE CONTENT AND COMPACTED TO AT LEAST 95
EXCEEDING 8 INCHES IN LOOSE THICKNESS, MOISTURE-CONDITIONED TO
STRUCTURAL FILL MATERIALS SHOULD BE PLACED IN LEVEL LIFTS NOT 7.
A WELL-GRADED MATERIAL.
TO PROVIDE THE REQUIRED GRADATION AND PARTICLE SIZES TO DEVELOP
LARGE-SIZED ROCK FRAGMENTS OR BOULDERS SHOULD BE CONSIDERED
TO PRODUCE A WELL-GRADED MATERIAL, OFF-SITE CRUSHING OF
IF THE EXCAVATED ON-SITE MATERIALS DO NOT CONTAIN SUFFICIENT FINES 6.
REQUIREMENTS.
PROCESSED TO MEET MAXIMUM PARTICLE SIZE AND GRADATION
STRUCTURAL FILL MATERIALS, PROVIDED THAT THE MATERIALS ARE
EXCAVATED ON-SITE MATERIALS MAY BE RE-USED AS A SOURCE OF
PREVENT THE OCCURRENCE OF VOIDS IN THE COMPACTED MASS. THE
MATERIALS 1-1/2 INCHES IN LARGEST DIMENSION WITH SUFFICIENT FINES TO
STRUCTURAL FILL MATERIALS SHALL CONSIST OF WELL-GRADE GRANULAR 5.
STRUCTURAL FILL AS REQUIRED.
MATERIAL, INCLUDING ASH AND ORGANICS AND REPLACE WITH COMPACTED
CONTRACTOR'S GEOTECHNICAL ENGINEER. REMOVE UNSATISFACTORY
SHALL BE NOTIFIED. FOOTINGS MAY BE ALTERED AS REQUIRED BY THE
EXPECTED CONDITIONS, THE CONTRACTOR'S GEOTECHNICAL ENGINEER
SOIL ENCOUNTERED AT THESE DEPTHS APPEAR UNSTABLE AND VARY FROM
FOOTINGS SHALL BE PLACED ON UNDISTURBED EXISTING SOIL. SHOULD 4.
ARE FOUND AND GROUTING IS REQUIRED.
PSI). CONTRACTOR SHALL PROVIDE UNIT PRICE PER CUBIC YARD IF VOIDS
FOOTING). IF VOIDS ARE FOUND, FILL VOID WITH LEAN CONCRETE (f'c = 1,500
GREATER (FOR EXAMPLE, MINIMUM 24'-0" DEEP PROBE AT 12'-0" WIDE
MINIMUM DEPTH OF 2 TIMES THE FOOTING WIDTH OR 10 FEET WHICHEVER IS
FOOTING AND EVERY 20 FEET OF WALL FOOTING. PROBE SHALL EXTEND A
PROVIDE A MINIMUM OF ONE PROBE FOR VOIDS BELOW EACH COLUMN
VOIDS THAT MAY BE ENCOUNTERED DURING FOUNDATION CONSTRUCTION.
SPECIAL CONSIDERATION SHALL BE GIVEN TO LAVA TUBES AND OTHER
= 0.25COEFFICIENT OF FRICTION
PCF= 150LATERAL PASSIVE PRESSURE
= 75 PCF (ASSUMED)AT-REST PRESSURE
= 50 PCF (ASSUMED)ACTIVE PRESSURE
AS WIND OR SEISMIC (ASSUMED)
SHORT DURATION LOADS SUCH
= 2,000 PSF W/ 1/3 INCREASE FOR ALLOWABLE BEARING PRESSURE
FOUNDATION DESIGN PARAMETERS:3.
CONTRACTOR SHALL HIRE AND PAY FOR A GEOTECHNICAL ENGINEER.2.
CODE, TABLE 1806.2, ITEM 4.
THE FOUNDATION DESIGN IS BASED ON THE 2015 INTERNATIONAL BUILDING 1.
FOUNDATION
SHALL APPLY.
DRAWINGS AND SPECIFICATIONS, THE MORE STRINGENT REQUIREMENT
SHOULD THERE BE CONFLICTS IN THE REQUIREMENTS BETWEEN THE 13.
SUBMITTED TO CONTRACTING OFFICER WITHIN 72 HOURS.
SPECIAL INSPECTION. ALL SPECIAL INSPECTION REPORTS SHALL BE
LEAST 2 DAYS IN ADVANCE FOR WORK TO BE PERFORMED REQUIRING
SAFETY ON SITE. CONTRACTOR SHALL NOTIFY SPECIAL INSPECTOR AT
ACCORDANCE WITH THE DRAWINGS AND SPECIFICATIONS AND TO PROVIDE
CONTRACTOR OF HIS RESPONSIBILITIES TO COMPLETE THE PROJECT IN
AND TESTING SERVICES. SPECIAL INSPECTION SHALL NOT RELIEVE THE
CONTRACTOR SHALL HIRE AND PAY FOR THIRD-PARTY SPECIAL INSPECTION
REQUIREDUPLIFT TIESG.
REQUIREDMASONRY (LEVEL B)F.
REQUIREDEPOXY EMBEDSE.
REQUIREDANCHOR BOLTSD.
REQUIREDHIGH-STRENGTH BOLTSC.
REQUIREDREINFORCING STEEL B.
REQUIREDCONCRETE A.
STRUCTURAL DRAWINGS.
GOVERNING PORTIONS OF THE STRUCTURAL WORK SHOWN IN THE
PROVISIONS OF SECTION 1704 OF THE 2015 INTERNATIONAL BUILDING CODE
ALL SPECIAL INSPECTION SHALL BE DONE PER IBC SPECIAL INSPECTIONS
STRUCTURAL SPECIAL INSPECTION REQUIREMENTS:12.
= BALANCED DESIGNDESIGN METHOD
= 6 DEGREESEND ROTATION LIMIT
= 7DUCTILITY RATIO LIMIT
4-010-01
PER TABLE 2-1 OF UFC
ACCORDING TO ASTM F1642
= “VERY LOW HAZARD” GLASS PERFORMANCE RATING
= 55.4 PSI-MSECFULLY REFLECTED POSITIVE IMPULSE
= 15.8 PSIPEAK REFLECTED POSITIVE PRESSURE
THAT IS NOT CONTROLLED
PARAMETERS APPLYING TO WINDOWS 50 FEET OR MORE FROM PARKING
WINDOW DYNAMIC BLAST PARAMETERS
= D SEISMIC DESIGN CATEGORY
= 0.60g D1
S = 1.00g
DS
S
= DSITE CLASS
= 0.60g
S
= 1.50g S
S
II =RISK CATEGORY
= 1.00 IMPORTANCE FACTOR
D. SEISMIC (ASCE 7-10)
= 1.5
ZT
K
= CWIND EXPOSURE
II= RISK CATEGORY
= 130 MPHBASIC WIND SPEED
C. WIND (ASCE 7-10)
FLOOR LOADS TYPICALLY SUPPORTED BY SLAB ON GRADE.
ALL LIVE LOADS REDUCIBLE, UON
= 20 PSFROOF (FLAT TO LESS THAN 4:12)
= 100 PSFLAUNDRY
= 100 PSFLATRINE
= 100 PSFSHOWER
= 100 PSFGP ADMIN (SMALL)
= 100 PSFBARRACKS (LARGE)
B. LIVE LOADS
UFC 3-301-01A. GENERAL STRUCTURAL DESIGN
DESIGN CRITERIA11.
FLOORS OR ROOF.
CONSTRUCTION MATERIALS SHALL BE SPREAD OUT IF PLACED ON FRAMED 10.
STRUCTURAL MEMBERS.
NOT SHOWN ON THE STRUCTURAL DRAWINGS, BUT WHICH ARE LOCATED IN
DRAWINGS BY OTHERS SHOW OPENINGS, POCKETS, ETC., LARGER THAN 6"
STRUCTURAL DRAWINGS. NOTIFY THE CONTRACTING OFFICER WHEN
SLABS, BEAMS, WALLS, ETC., UNLESS SPECIFICALLY DETAILED ON THE
OPENINGS, POCKETS, ETC. LARGER THAN 6" SHALL NOT BE PLACED IN
CONCRETE OR OTHERWISE INCORPORATED IN STRUCTURAL WORK
SLEEVES, ELECTRICAL CONDUITS AND OTHER ITEMS TO BE EMBEDDED IN
LOCATION OF ALL OPENINGS REQUIRED FOR DUCTS, PIPES AND ALL PIPE
SEE MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS FOR SIZE AND 9.
AND WALL OPENINGS, FLOOR FINISHES, ETC.
SEE ARCHITECTURAL DRAWINGS FOR SIZE AND LOCATION OF ALL FLOOR 8.
SHOP DRAWINGS WILL BE REJECTED.
PHOTOCOPIES OR DUPLICATES OF CONTRACT DOCUMENTS SUBMITTED AS
TO THE CONTRACTING OFFICER FOR REVIEW PRIOR TO FABRICATION.
SHOP DRAWINGS REQUIRED BY THE SPECIFICATIONS SHALL BE SUBMITTED 7.
DIMENSIONS.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING ALL 6.
GENERAL NOTES AND TYPICAL DETAILS.
NOTES AND DETAILS ON DRAWINGS SHALL TAKE PRECEDENCE OVER 5.
PROCEEDING WITH THE WORK.
ATTENTION OF THE CONTRACTING OFFICER AND BE RESOLVED BEFORE
EXISTING STRUCTURES. ALL DISCREPANCIES SHALL BE CALLED TO THE
THE WORK OF ALL TRADES AND SHALL CHECK ALL DIMENSIONS INCLUDING
THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR COORDINATING 4.
PROPERTY AND UTILITIES.
PROCEDURES INCLUDING LAGGING, SHORING AND PROTECTION OF
THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL EXCAVATION 3.
RESPONSIBILITIES.
NOR RELIEVE THE CONTRACTOR OF HIS/HER OBLIGATIONS, DUTIES AND
GOVERNMENT'S A/E SHALL NOT INCLUDE INSPECTION OF THE ABOVE ITEMS
OBSERVATION VISITS TO THE SITE BY THE CONTRACTING OFFICER AND
STRUCTURAL ENGINEER HIRED AND PAID FOR BY THE CONTRACTOR.
SHORING AND BRACING SYSTEMS SHALL BE DESIGNED BY A LICENSED
DUE TO CONSTRUCTION EQUIPMENT, WIND AND SEISMIC LOADING. ALL
SHALL INCLUDE, BUT NOT BE LIMITED TO BRACING, SHORING FOR LOADS
PROTECT THE STRUCTURE DURING CONSTRUCTION. SUCH MEASURES
SHALL BE RESPONSIBLE FOR AND PROVIDE ALL MEASURES NECESSARY TO
DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR
THE STRUCTURAL DRAWINGS REPRESENT THE FINISHED STRUCTURE AND 2.
AND SPECIFICATIONS.
ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE DRAWINGS 1.
GENERAL
AREA OF WORK AS NECESSARY.
DRAWINGS. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING DIMENSIONS IN
ALL EXISTING BUILDING DIMENSIONS ARE BASED ON AVAILABLE EXISTING 5.
CONCRETE AND CMU WALLS AND SLABS.
NEW PIPES AND CONDUITS SHALL NOT BE EMBEDDED IN EXISTING 4.
NEW OPENINGS IN EXISTING SLABS AND WALLS SHALL NOT BE OVERCUT.3.
TO THE CONTRACTING OFFICERS'S ATTENTION PRIOR TO STARTING WORK.
STARTING WORK. ANY DISCREPANCIES WITH DRAWINGS SHALL BE BROUGHT
DIMENSIONS SHALL BE VERIFIED BY CONTRACTOR IN FIELD PRIOR TO
SEE ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS. ALL EXISTING 2.
DEMOLITION WORK.
CONTRACTOR SHALL PROVIDE ADEQUATE SHORING AND BRACING FOR ALL 1.
DEMOLITION NOTES
REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION.4.
FIBER WRAP SYSTEM SHALL CONFORM TO ACI 440.2R.3.
AS A MINIMUM.
LOCATIONS AND FORCE DEMANDS THAT FIBER WRAP SYSTEM MUST RESIST
STRUCTURAL DRAWINGS BY NAGAMINE OKAWA ENGINEERS INC. PROVIDE 2.
FOR REVIEW AND COMMENT.
WRAP DESIGN ENGINEER SHALL BE PROVIDED TO CONTRACTING OFFICER
CALCULATIONS AND SHOP DRAWINGS STAMPED AND SIGNED BY FIBER
AND SHALL BE DESIGNED BY A LICENSED STRUCTURAL ENGINEER.
FIBER WRAP STRENGTHENING SHALL BE PROVIDED BY THE CONTRACTOR 1.
FIBER WRAP STRENGTHENING
SUSPENDED CEILINGS, MECHANICAL DUCTS, PIPING, ETC.
METAL DECKING WITHOUT TOPPING SHALL NOT BE USED TO SUPPORT 12.
ALL WELDS SHALL HAVE TOUCH-UP.
MANUFACTURER'S RECOMMENDATIONS. UPON COMPLETION OF ERECTION,
INDICATED ON THE DRAWINGS AND IN ACCORDANCE WITH
BE ATTACHED TO ALL SUPPORTING STEEL MEMBERS BY WELDING AS
MINIMUM BEARING OF DECKING ON SUPPORTS SHALL BE 2". SHEETS SHALL 11.
SHALL SPAN OVER THREE OR MORE SUPPORTS.
PROTECTIVE COATING OF ZINC (G60). SEE SPECIFICATIONS. DECK UNITS
CONFORMING TO ASTM A446, GRADE A. THE STEEL SHALL HAVE A METAL
STEEL SHEETS HAVING A MINIMUM YIELD STRENGTH OF 33,000 PSI AND
THE DRAWINGS. DECKING AND ALL ACCESSORIES SHALL BE FORMED FROM
THE STEEL DECKING SHALL BE OF THE TYPE AND GAUGE AS CALLED FOR ON 10.
5,000 PSI. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION.
CONCRETE WALLS, ETC., SHALL BE NON-SHRINK, NON-STAINING, WITH f'c =
ALL GROUT (OR DRYPACK) BELOW BASE PLATES, BEAMS BEARING ON 9.
COATED WITH TWO COATS OF ZINC RICH PRIMER.
ASTM A123 OR A153. ALL WELDS AFTER HOT DIP GALVANIZING SHALL BE
HOT DIP GALVANIZED STEEL REFERENCED ON PLAN SHALL CONFORM TO 8.
SPECIFICATIONS.
CODE AWS D1.1-04 OF THE AMERICAN WELDING SOCIETY; SEE
ALL WELDS SHALL BE IN CONFORMITY WITH THE STRUCTURAL WELDING 7.
MASONRY SHALL BE CLEAN AND LEFT UNPAINTED.
ALL STRUCTURAL STEEL SURFACES THAT ARE ENCASED IN CONCRETE OR 6.
SIZE OF BOLT USED, UNLESS OTHERWISE NOTED.
BOLT HOLES IN STEEL SHALL BE 1/16" LARGER DIAMETER THAN NOMINAL 5.
REVIEW BEFORE FABRICATION.
ALL STRUCTURAL STEEL RESPECTIVELY, FOR CONTRACTING OFFICER'S
THE STRUCTURAL STEEL FABRICATOR SHALL FURNISH SHOP DRAWINGS OF 4.
GALVANIZED.
RODS EPOXY EMBEDDED SHALL CONFORM TO ASTM A36 AND BE HOT DIP
CONFORMING TO ASTM A325 OR A490. UNLESS OTHERWISE NOTED, ANCHOR
UNLESS OTHERWISE NOTED. USE ALTERNATIVE DESIGN FASTENER
ALL BOLTS SHALL CONFORM TO ASTM A325N HIGH STRENGTH BOLTS, 3.
= A500, GRADE BTUBES
= A500, GRADE BPIPES
= A36PLATES, MISC. STEEL
CHANNELS, ANGLES, TEES,
= A992, GRADE 50WIDE FLANGES
DESIGNATIONS:
STRUCTURAL STEEL SECTIONS SHALL CONFORM TO THE FOLLOWING ASTM 2.
FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS."
ACCORDANCE WITH THE "AISC SPECIFICATION FOR THE DESIGN,
STRUCTURAL STEEL SHALL BE DETAILED, FABRICATED AND ERECTED IN 1.
STRUCTURAL STEEL
STEEL" OF THE AMERICAN WELDING SOCIETY.
CONFORM TO AWS D1.4 "AWS STRUCTURAL WELDING CODE - REINFORCING
SHOWN ON THE DRAWINGS. WELDING OF REINFORCING STEEL SHALL
WELDING OF REINFORCING STEEL IS NOT PERMITTED UNLESS OTHERWISE 8.
FROM REVIEWED DRAWINGS ONLY.
CONTRACTING OFFICER'S REVIEW PRIOR TO FABRICATION. FABRICATE
CONTRACTOR SHALL SUBMIT REINFORCING BAR LAYOUTS AND DETAILS FOR 7.
MODIFIED BY THE PROJECT DRAWINGS AND SPECIFICATIONS.
CONFORMANCE WITH THE "ACI DETAILING MANUAL - 2004" (SP-66) AS
ALL REINFORCING STEEL SHALL BE DETAILED AND PLACED IN 6.
ALL REINFORCING BAR BENDS SHALL BE MADE COLD.5.
SECURELY TIED IN PLACE BEFORE CONCRETE IS POURED.
ANCHOR BOLTS, DOWELS AND OTHER EMBEDDED ITEMS ARE TO BE 4.
DRAWINGS.
REINFORCING SPLICES SHALL BE MADE ONLY WHERE INDICATED ON THE 3.
U.O.N.
AND SPACING OR NUMBERS AS THE VERTICAL REINFORCING RESPECTIVELY,
DOWELS BETWEEN FOOTING AND WALL SHALL BE THE SAME GRADE, SIZE 2.
REQUIREMENTS OR ASTM A706 WHERE WELDING IS REQUIRED.
REINFORCING BARS SHALL CONFORM TO ASTM A-615 GRADE 60 1.
REINFORCING STEEL
SUPPLIER.
FOR RETARDATION BY THE ADMIXTURE MANUFACTURER OR THE CONCRETE
MINUTES PER SPECIFICATIONS MAY BE INCREASED BY THE TIME SPECIFIED
IF A RETARDING ADMIXTURE IS USED, THE DISCHARGE TIME LIMIT OF 90 12.
AMPLITUDE OF 1/4".
ALL ROUGHENED SURFACES IN CONCRETE SHALL BE MADE WITH A MINIMUM 11.
SHALL NOT BE USED.
CONCRETE ADMIXTURES CONTAINING CHLORIDE OR CHLORIDE SALTS 10.
SPECIFYING CONCRETE POURS IN UPCOMING THREE WEEKS.
CONTRACTOR SHALL PROVIDE THE CONTRACTING OFFICER A SCHEDULE 9.
BEFORE USE.
ARCHITECTURAL FINISH SHALL BE APPROVED BY THE FINISH SUPPLIER
CURING COMPOUNDS USED ON CONCRETE THAT IS TO RECEIVE AN 8.
SHOWN ON THE DRAWINGS.
NOTIFY THE CONTRACTING OFFICER IN ADVANCE OF CONDITIONS NOT
CONFLICT. CORING IN CONCRETE IS NOT PERMITTED EXCEPT AS SHOWN.
CONCRETE BEFORE PLACING. DO NOT CUT ANY REINFORCING WHICH MAY
PROVIDE SLEEVES FOR PLUMBING AND ELECTRICAL OPENINGS IN 7.
SHALL BE WELL SECURED IN POSITION PRIOR TO PLACING CONCRETE.
ALL REINFORCING BARS, ANCHOR BOLTS AND OTHER CONCRETE INSERTS 6.
1" CLEAR TO REINFORCINGWALLSC.
BE AS FOLLOWS (U.O.N.):
CLEAR COVERAGE OF CONCRETE OVER OUTER REINFORCING BARS SHALL 5.
PROJECT SITE.
SHALL ACCOUNT FOR TRAVEL TIME AND TEMPERATURE CONDITIONS AT THE
OFFICER FOR REVIEW PRIOR TO CONSTRUCTION. CONCRETE MIX DESIGN
WHERE MIX IS USED. MIX DESIGN SHALL BE SUBMITTED TO CONTRACTING
CONCRETE MIX DESIGN SUBMITTAL SHALL STATE LOCATION OF STRUCTURE 4.
4,000 PSIMISC…