VOL5.PDF
PDF 29 MB Posted
- Attached to
- Cyberspace Test Group Facility, Eglin AFB, FL Federal contract opportunity
- Solicitation number
- W9127820R0057
About this file
This document provides details for a federal contract opportunity for construction services. The solicitation is for the construction of a new Cyberspace Test Group Facility at Eglin Air Force Base in Florida. The 52,003 square foot facility will include a multi-level sensitive compartmented information facility utilizing conventional construction methods. It will have a concrete foundation, split-faced concrete block and steel frame construction, and a sloped standing seam metal roof. The facility will also include fire suppression systems, all utilities, pavements, communications, site improvements and support facilities. The contract is being issued by the Department of the Army Corps of Engineers Engineering District Mobile. The solicitation number is W9127820R0057 and responses are due by the date specified in the solicitation.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| W9127820R0057 JA_Redacted.pdf | ||
| AM05.pdf | ||
| AM05 DRAWINGS.pdf | ||
| AM04.pdf | ||
| AM03 DRAWINGS.pdf | ||
| AM03.pdf | ||
| AM02 DRAWINGS.pdf | ||
| AM02.pdf | ||
| AM01.pdf | ||
| AM01 DRAWINGS.pdf | ||
| Site visit sign in sheet.pdf | ||
| VOL1.PDF | ||
| VOL6.PDF | ||
| VOL2.PDF | ||
| EM 385-1-1.pdf | ||
| RTA DRAWINGS VOL2 .pdf | ||
| VOL3.PDF | ||
| VOL4.PDF | ||
| RTA DRAWINGS VOL1.pdf |
Show all 19
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
THIS PROJECT IS ADVERTISED ON AN UNRESTRICTED BASIS
VOLUME 5 OF 6
SOLICITATION NO: W9127820R0057
CADD NO: MEF19017
SPECIFICATIONS
FOR
CYBERSPACE TEST GROUP FACILITY FTFA 163007
EGLIN AIR FORCE BASE, FLORIDA
(OKALOOSA COUNTY)
“GOOD ENGINEERING RESULTS IN A BETTER ENVIRONMENT”
U.S. ARMY ENGINEER DISTRICT, MOBILE
109 St. Joseph St
Mobile, Alabama 36602
CYBERSPACE TEST GROUP FACILITY FTFA 163007 W9127820R0057
EGLIN AIR FORCE BASE, FLORIDA MEF19017
TOC - 1
TABLE OF CONTENTS
VOLUME 1 OF 6
CHECKLIST FOR PREPARATION OF OFFERS
BIDDING REQUIREMENTS
STANDARD FORM 1442 - SOLICITATION, OFFER, AND AWARD
BIDDING SCHEDULE
EXPLANATION OF BID ITEMS
STANDARD FORM 24 - BID BOND
STANDARD FORM 28 - AFFIDAVIT OF INDIVIDUAL SURETY
STANDARD FORM LLL - DISCLOSURE OF LOBBYING ACTIVITIES
SMALL BUSINESS SUBCONTRACTING PLAN TEMPLATE
00 11 00 PROPOSAL SUBMISSION REQUIREMENTS AND INSTRUCTIONS
00 12 00 EVALUATION CRITERIA AND BASIS OF AWARD
00 21 16 INSTRUCTIONS TO PROPOSERS
00 45 00 REPRESENTATIONS AND CERTIFICATIONS
00 70 00 CONDITIONS OF THE CONTRACT
SPECIFICATIONS
DIVISION 01 - GENERAL REQUIREMENTS
01 00 00 ADDITIONAL SPECIAL CONTRACT REQUIREMENTS
BASE ACCESS FORM
EP310-1-6a PROJECT SIGNS
DD FORM 1354
DD FORM 1354 CHECKLIST
WAGE RATES
01 00 01 GENERAL CONTRACT REQUIREMENTS
CESAM FORM 1151
01 11 00 SUMMARY OF WORK
01 14 00 WORK RESTRICTIONS
01 32 01.00 10 PROJECT SCHEDULE
01 33 00 SUBMITTAL PROCEDURES
SUBMITTAL REGISTER
FORM 4025
01 33 29 SUSTAINABILITY REQUIREMENTS
01 35 26 GOVERNMENTAL SAFETY REQUIREMENTS
01 42 00 SOURCES FOR REFERENCE PUBLICATIONS
01 45 00.00 10 QUALITY CONTROL
01 45 00.15 10 RESIDENT MANAGEMENT SYSTEM CONTRACTOR MODE (RMS CM)
SAM FORM 696
01 45 35 SPECIAL INSPECTIONS
STATEMENT OF SPECIAL INSPECTIONS
SCHEDULE OF SPECIAL INSPECTIONS
01 57 19 TEMPORARY ENVIRONMENTAL CONTROLS – EGLIN STANDARD
01 74 19 CONSTRUCTION WASTE MANAGEMENT AND DISPOSAL
01 78 23 OPERATION AND MAINTENANCE DATA
01 91 00.15 TOTAL BUILDING COMMISSIONING
DIVISION 02 - EXISTING CONDITIONS
02 41 00 DEMOLITION
DIVISION 03 - CONCRETE
03 30 53 MISCELLANEOUS CAST-IN-PLACE CONCRETE
TOC - 2
DIVISION 04 - MASONRY
04 20 00 UNIT MASONRY
DIVISION 05 - METALS
05 12 00 STRUCTURAL STEEL
05 21 00 STEEL JOIST FRAMING
05 30 00 STEEL DECKS
05 40 00 COLD-FORMED METAL FRAMING
05 50 13 MISCELLANEOUS METAL FABRICATIONS
05 51 00 METAL STAIRS
05 51 33 METAL LADDERS
05 52 00 METAL RAILINGS
VOLUME 2 OF 6
DIVISION 06 - WOOD, PLASTICS, AND COMPOSITES
06 10 00 ROUGH CARPENTRY
06 41 16.00 10 LAMINATE CLAD ARCHITECTURAL CASEWORK
06 61 16 SOLID POLYMER (SOLID SURFACING) FABRICATIONS
DIVISION 07 - THERMAL AND MOISTURE PROTECTION
07 05 23 PRESSURE TESTING AN AIR BARRIER SYSTEM FOR AIR TIGHTNESS
07 13 53 ELASTOMERIC SHEET WATERPROOFING
07 21 13 BOARD AND BLOCK INSULATION
07 21 16 MINERAL FIBER BLANKET INSULATION
07 22 00 ROOF AND DECK INSULATION
07 27 26 FLUID-APPLIED MEMBRANE AIR BARRIERS
07 41 13 METAL ROOF PANELS
07 42 13 METAL WALL PANELS
07 52 00 MODIFIED BITUMINOUS MEMBRANE ROOFING
07 60 00 FLASHING AND SHEET METAL
07 72 00 ROOFTOP FALL PROTECTION AND ACCESSORIES
07 84 00 FIRESTOPPING
07 92 00 JOINT SEALANTS
DIVISION 08 - OPENINGS
08 11 13 STEEL DOORS AND FRAMES
08 14 00 WOOD DOORS
08 31 00 ACCESS DOORS AND PANELS
08 33 23 OVERHEAD COILING DOORS
08 34 73 SOUND CONTROL DOOR ASSEMBLIES
08 41 13 ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS
08 44 00 CURTAIN WALL AND GLAZED ASSEMBLIES
08 51 13 ALUMINUM WINDOWS
08 71 00 DOOR HARDWARE
HARDWARE SETS
08 81 00 GLAZING
08 91 00 METAL WALL LOUVERS
DIVISION 09 - FINISHES
09 06 00 SCHEDULES FOR FINISHES
09 22 00 SUPPORTS FOR PLASTER AND GYPSUM BOARD
TOC - 3
DIVISION 09 – FINISHES (CONTINUED)
09 29 00 GYPSUM BOARD
09 30 10 CERAMIC, QUARRY, AND GLASS TILING
09 51 00 ACOUSTICAL CEILINGS
09 62 38 STATIC-CONTROL FLOORING
09 65 00 RESILIENT FLOORING
09 66 16 TERRAZZO FLOOR TILE
09 67 23.13 STANDARD RESINOUS FLOORING
09 68 00 CARPETING
09 69 13 RIGID GRID ACCESS FLOORING
09 72 00 WALLCOVERINGS
09 90 00 PAINTS AND COATINGS
DIVISION 10 - SPECIALTIES
10 14 00.10 EXTERIOR SIGNAGE
10 14 02 INTERIOR SIGNAGE
10 21 13 TOILET COMPARTMENTS
10 26 00 WALL AND DOOR PROTECTION
10 28 13 TOILET ACCESSORIES
10 73 16 CANTILEVERED ENTRANCE CANOPY
DIVISION 11 – EQUIPMENT
11 13 19.13 LOADING DOCK LEVELERS
DIVISION 12 - FURNISHINGS
12 24 13 ROLLER WINDOW SHADES
12 48 13 ENTRANCE FLOOR MATS AND FRAMES
12 59 00 SYSTEMS FURNITURE
12 70 00 FURNITURE, FIXTURES AND EQUIPMENT
DIVISION 13 – SPECIAL CONSTRUCTION
13 12 20 EXTRUDED ALUMINUM CANOPY SYSTEM
DIVISION 14 - CONVEYING EQUIPMENT
14 24 23 HYDRAULIC PASSENGER ELEVATORS
VOLUME 3 OF 6
DIVISION 21 - FIRE SUPPRESSION
21 13 13.00 10 WET PIPE SPRINKLER SYSTEM, FIRE PROTECTION
21 30 00 FIRE PUMPS
DIVISION 22 - PLUMBING
22 00 00 PLUMBING, GENERAL PURPOSE
DIVISION 23 - HEATING, VENTILATING, AND AIR CONDITIONING (HVAC)
23 00 00 AIR SUPPLY, DISTRIBUTION, VENTILATION, AND EXHAUST SYSTEMS
23 05 93 TESTING, ADJUSTING, AND BALANCING FOR HVAC
23 07 00 THERMAL INSULATION FOR MECHANICAL SYSTEMS
23 09 23.13 20 BACnet DIRECT DIGITAL CONTROL SYSTEMS FOR HVAC
TOC - 4
23 64 10 WATER CHILLERS, VAPOR COMPRESSION TYPE
DIVISION 23 - HEATING, VENTILATING, AND AIR CONDITIONING (HVAC) (CONTINUED)
23 64 26 CHILLED, CHILLED-HOT, AND CONDENSER WATER PIPING SYSTEMS
23 73 13 MODULAR INDOOR CENTRAL-STATION AIR-HANDLING UNITS
23 81 23.00 20 COMPUTER ROOM AIR CONDITIONING UNITS
DIVISION 26 - ELECTRICAL
26 00 00.00 20 BASIC ELECTRICAL MATERIALS AND METHODS
26 08 00 APPARATUS INSPECTION AND TESTING
26 20 00 INTERIOR DISTRIBUTION SYSTEM
26 24 13 SWITCHBOARDS
26 28 01.00 10 COORDINATED POWER SYSTEM PROTECTION
26 32 15.00 10 DIESEL-GENERATOR SET STATIONARY 100-2500 KW, WITH
AUXILIARIES
26 33 53 STATIC UNINTERRUPTIBLE POWER SUPPLY (UPS)
26 35 43 400-HERTZ (HZ) SOLID STATE FREQUENCY CONVERTER
26 36 00.00 10 AUTOMATIC TRANSFER SWITCH AND BY-PASS/ISOLATION SWITCH
26 41 00 LIGHTNING PROTECTION SYSTEM
26 42 14.00 10 CATHODIC PROTECTION SYSTEM (SACRIFICIAL ANODE)
26 51 00 INTERIOR LIGHTING
26 56 00 EXTERIOR LIGHTING
DIVISION 27 - COMMUNICATIONS
27 05 28.36 40 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS
27 05 29.00 10 PROTECTIVE DISTRIBUTION SYSTEM (PDS) FOR SIPRNET
COMMUNICATION SYSTEMS
27 10 00 BUILDING TELECOMMUNICATIONS CABLING SYSTEM
27 51 16 RADIO AND PUBLIC ADDRESS SYSTEMS
27 54 00.00 20 COMMUNITY ANTENNA TELEVISION (CATV) SYSTEMS
DIVISION 28 - ELECTRONIC SAFETY AND SECURITY
28 08 10 ELECTRONIC SECURITY SYSTEM ACCEPTANCE TESTING
28 10 05 ELECTRONIC SECURITY SYSTEMS (ESS)
28 31 76 INTERIOR FIRE ALARM AND MASS NOTIFICATION SYSTEM
VOLUME 4 OF 6
DIVISION 31 - EARTHWORK
31 00 00 EARTHWORK
31 11 00 CLEARING AND GRUBBING
31 31 16.13 CHEMICAL TERMITE CONTROL
DIVISION 32 - EXTERIOR IMPROVEMENTS
32 01 19 FIELD MOLDED SEALANTS FOR SEALING JOINTS IN RIGID PAVEMENTS
32 05 33 LANDSCAPE ESTABLISHMENT
32 11 23 AGGREGATE BASE COURSES
32 12 13 BITUMINOUS TACK AND PRIME COATS
32 12 16 HOT-MIX ASPHALT (HMA) FOR ROADS
32 13 13.06 PORTLAND CEMENT CONCRETE PAVEMENT FOR ROADS AND SITE
FACILITIES
32 13 14.13 CONCRETE PAVING FOR AIRFIELDS AND OTHER HEAVY DUTY PAVEMENTS
32 13 73.19 COMPRESSION CONCRETE PAVING JOINT SEALANT
32 16 19 CONCRETE CURBS, GUTTERS AND SIDEWALKS
32 17 23 PAVEMENT MARKINGS
TOC - 5
32 31 13.53 HIGH-SECURITY CHAIN LINK FENCES AND GATES
DIVISION 32 - EXTERIOR IMPROVEMENTS (CONTINUED)
32 92 19 SEEDING
32 92 23 SODDING
32 93 00 EXTERIOR PLANTS
DIVISION 33 - UTILITIES
33 11 00 WATER UTILITY DISTRIBUTION PIPING
33 30 00 SANITARY SEWERAGE
33 40 00 STORM DRAINAGE UTILITIES
33 71 02 UNDERGROUND ELECTRICAL DISTRIBUTION
33 82 00 TELECOMMUNICATIONS OUTSIDE PLANT (OSP)
DIVISION 41 – MATERIAL PROCESSING AND HANDLING EQUIPMENT
41 22 23.19 MONORAIL HOISTS
VOLUME 5 OF 6
APPENDICES
APPENDIX A FURNITURE, FIXTURES, AND EQUIPMENT (FFE) PACKAGE
APPENDIX B BORING LOGS AND RESISTIVITY TEST DATA
APPENDIX C AIR FORCE FORMS 813
AF 813 PRIMARY SITE AREA NORTH OF DAYTONA ROAD
& AF 813 UTILITY SITES AND NEW PARKING LOT SITE SOUTH
OF DAYTONA ROAD
APPENDIX D AF FORM 103, BASE CIVIL ENGINEERING WORK CLEARANCE REQUEST
APPENDIX E EGLIN AIR FORCE BASE
PRE-CONSTRUCTION (PRECON) ENVIRONMENTAL MANAGEMENT CHECKLIST
(V12) EFFECTIVE: 6 MARCH 2019
APPENDIX F EXISTING COMM MANHOLE BUTTERFLY DIAGRAMS
APPENDIX G EGLIN BEST PRACTICE 1 – TEMPLATE FOR SMS BUILDER
APPENDIX H 96TH COMMUNICATIONS SQUADRON CYBER INFRASTRUCTURE DESIGN
GUIDE APRIL 2019
APPENDIX I AMERICAN STATES UTILITY SERVICES, INC. (ASUS)
STANDARD DETAILS AND SPECIFICATIONS - WATER AND SEWER
VOLUME 6 OF 6
APPENDICES (CONTINUED)
APPENDIX J CHELCO STANDARDS
APPENDIX K TECHNICAL SPECIFICATIONS FOR CONSTRUCTION AND MANAGEMENT OF
SENSITIVE COMPARTMENTED INFORMATION FACILITIES (VERSION 1.4)
IC TECH SPEC-FOR ICD/ICS 705, DATED SEPTEMBER 28, 2017
and UFC 4-010-05 (1 February 2013, Change 1, 1 October 2013)
SENSITIVE COMPARTMENTED INFORMATION FACILITIES PLANNING,
DESIGN, AND CONSTRUCTION
and
DODM 5200.01 VOL 3, APPENDIX TO ENCLOSURE 3 PHYSICAL
SECURITY
STANDARDS, DATED FEBRUARY 24, 2012
APPENDIX L EXISTING BUILDING 85 FIRST FLOOR PLAN (For Information Only)
-- End of Project Table of Contents --
This page was intentionally left blank for duplex printing.
APPENDIX A
FURNITURE, FIXTURES, AND EQUIPMENT (FFE) PACKAGE
This page left blank.
US Army Corps of Engineers Mobile District
14 MAY 2020
FY19
Cyberspace Test
Group Facility Eglin AFB, Florida
FTFA163007
100% RTA FF&E SUBMITTAL100% RTA FF&E SUBMITTAL
Prepared by
Bullock Tice Associates Pensacola, Florida
FY19 Cyberspace Test Group Facility Eglin AFB, Florida
FTFA163007
FFE/Comprehensive Interior Design 100% RTA Submittal
Design Analysis………………………………………………………………………..1
Specification Section 12 59 00………………………………………………………4
Specification Section 12 70 00……………………………..………………………20
Order Data Sheets
• Accessories……………………………….……………………………………24
• Audio-Visual……………………………………………………………………46
• Demountable Partitions…………………….…………………………………48
• Desking…………………………………………………………………………52
• Equipment…………………………………………………..………………….61
• Files & Storage………………….……………………………………………..70
• Seating………………………………………………………………………….84
• Tables………………..…….………………………………………………….101
• Workstations………………………………………………………………….112
Drawings
• I-109 thru I-112 Furniture Plans
• I-140 thru I-143 Workstation Groups and Individual Workstation Typicals
• I-201 thru I-203 Elevations
Color Boards
Chapter 7 - FF&E Comprehensive Interior Design (FF&E/CID)
A. Design Criteria
The following is a list of DoD, Air Force and Eglin AFB specific criteria that shall be utilized for the design of this facility. Refer to other chapters for additional criteria specific to each design element.
1. Engineering Design Manual Eglin AFB, Florida, February 2019 with referenced:
a. Eglin AFB Architectural Compatibility Plan – 2012
b. 96th Communications Squadron Cyber Infrastructure Design Guide 10 April 2019
c. CHELCO Design and Construction Standards, December 1, 2008
d. American States Utility Services, Inc. (ASUS) Standard Details Water and Sewer
2. US Army Corps of Engineers Mobile District Design Manual, March 2007
3. UFC 1-200-01 General Building Design, Change 2, 1 November 2018
4. UFC 3-600-01 Fire Protection, Change 1, 28 Nov 2016
5. UFC 4-010-01 DoD Minimum Antiterrorism Standards for Buildings, 12 December 2018
6. UFC 4-021-01 Mass Notification System, Change 1, Jan 2010
7. International Building Code 2015
8. NFPA 101 2018
9. ABA Accessibility Guidelines, Current Version
10. UFC 1-200-02 High Performance Sustainable Building Requirements, 1 Dec 2016, Change 3, 7 Sept
2018.
11. AGRAM 17-01 Change to AF New Construction and Major Renovation Certification Requirements
(February 2017) changes guidance for 3rd Party Validation.
a. Air Force Sustainable Design & Development (SDD) Implementation Guidance, memorandum dated 2 June 2011
b. Air Force Sustainable Design and Development (SDD) Policy letter (31 July 2007)
12. E.O. 13423 Strengthening Federal Environmental, Energy & Transportation Management (Jan 2007)
13. E.O.13514 Federal Leadership in Environmental, Energy and Economic Performance (Oct 2009)
14. FLHPSB - Federal Leadership in High Performance and Sustainable Buildings MOU (HPSB) (Issued
2006)
15. EPAct2005 - Energy Policy Act Of 2005
16. EISA 2007 - Energy Independence Security Act Of 2007
17. UFC 4-010-05 Sensitive Compartmented Information Facilities Planning, Design and Construction, Dated 1 Feb 2013, Including Change 1, Dated 1 Oct 2013.
18. Technical Specifications for Construction and Management of Sensitive Compartmented Information
Facilities (Version 1.4) IC Tech Spec-For ICD/ICS 705, Dated September 28, 2017.
B. Design Statement
The 96CTG is a unique mission for Eglin Air Force Base. There are no existing facilities on Eglin AFB with the capability to collocate the number of personnel that the 96CTG will need to support the necessary testing equipment and laboratory space needed for the new missions Having this facility near Building 85 provides operational and staffing synergies critical to the success of the mission. Test and Evaluation is one of AFMC’s core mission areas. The AFTC mission to conduct DT&E of air, space, and cyberspace systems, and provide timely, objective, and accurate information to acquisition decision makers is critical. This facility will be a 21st Century design to respond to current and future needs.
C. FF&E/CID Design Statement
The Furniture, Fixtures & Equipment (FFE) effort includes all moveable furniture and furnishings layouts, the selection and specification of all furniture, furnishings, finishes, fabrics and accessories and the preparation of all procurement data. Furnishings are selected for functionality, performance, appearance retention and aesthetic qualities. Warranties are an important consideration for selection.
The interior design concept is to develop an aesthetic that reflects the technically advanced mission of the group yet is professional, polished and sophisticated. The FF&E selections and finish and color scheme will enhance the architectural design elements while delivering a visually dynamic space. The color palette is designed to reflect the 21st Century design aesthetic. The design team is committed to delivering a durable, easily maintained facility with high appearance retention factor. Every effort will be made to provide a smart sustainable facility using low-emitting adhesives, sealants and paints, with composite wood or agri-fiber materials and high-performance materials.
The design concept intent is to incorporate workstation designs that respond to the physical technical requirements that support the technology in use by individual users. The agreed direction was to maximize the available space to support the use of three computer monitors and one laptop. To be able to accommodate the number of personnel for each group, a 6’x8’ workstation module will be the standard used throughout. Each workstation will have an electric height-adjustable worksurface, a storage tower with box, file at the base and storage shelving above. Eliminating overhead storage cabinets and replacing them with slide out storage towers will allow adequate space for computer equipment and allow use of height adjust work surfaces for sit/stand functional environments. The 6’ dimension is the spine with the 8’ in the perpendicular direction and panels are 64” tall. The inside face of the workstation panels will consist of marker board and tackable surfaces for each. Some areas in the second floor will have the workstations arranged in teaming pods of four. Each open office area with multiple workstations will have a separate collaboration area created by using glass demountable partitions and doors, collaboration tables and seating and video walls. Areas for double and triple high computer stations with shredders and coffee cabinets will be interspersed throughout for efficiency.
E. Individual Room Requirements
GENERAL
Typical Workstation - Based on a 6’ x 8’ module with height adjustable and fixed height work surfaces.
Desktop shelving and slide-out style storage pedestal. Task chair, task light and marker boards will be included. Systems panels will surround the worksurfaces and be 64” high. Panels will have an acoustic core insert and sound transmission septum insert to provide enhanced acoustics. The tiles will provide a Noise Reduction Coefficient (NRC) of .80 and a Sound Transmission Class (STC) of 26.
Typical Office – Modular desk unit in L-shape with overhead storage, tack surfaces, fixed and height adjustable worksurfaces and file and book storage. One desk surface will be height adjustable to provide a sit/stand environment. Single task chair with two guest chairs.
Breakroom – First floor breakroom will have collaboration type high top tables and chairs. Cabinet, counter and equipment area provide coffee, microwaves, vending machines and refrigeration. Second floor breakroom will have sit-down height tables with casters and seating that is flexible and easy to reconfigure for various functions. Second floor breakroom will also have space for coffee, microwaves, snacks and refrigeration.
Test Suites – Each test suite will be set up with perimeter free standing worktables with casters and ganging mechanisms. The perimeter of each room will have a power strip just above desk height. The free-standing tables will give the users the flexibility to reconfigure each room for current or future needs.
Each table will have an ergonomic task chair. All furniture in the test suites will have electrostatic dissipative (ESD) properties.
Conference Rooms - The facility is designed with multiple conference and meeting rooms, each with various layouts but based on similar types of furniture for efficiency. 47CTS, NCR and ACR Conference Rooms are designed with rectangular interlocking training tables that can be reconfigured as needed. Event Design Collaboration Rooms 203 & 204 are designed to have joined tables that can function as a single collaboration space or separately for training or other functions. Each large conference room has task chairs at the table and armchair seating at the perimeter of the room. Conference rooms will have a video wall and glass marker boards at each side wall. The glass marker boards will be installed to be easily removable and installed away from the wall, clearing the face of the exposed conduit.
Cyber/EW Lab 139, Avionics Test Lab 136, Threat Development Lab 144 –The lab facilities in this building are the technical heart of this building. Each hot desk is 30” x 60”, each with 30” high worksurfaces.
Workbenches in this area are either 30” x 60” or 30” x 72” each with a worksurface 36” high. Final components to the hot desks and work benches must be coordinated with the user at time of placing order.
All hot desks, workbenches, cabinets and seating will have ESD characteristics, and will be on casters for flexibility. Placement of each item will be directed by the users. In the EW and Avionics Labs, each will have a fold up conference table, marker board on casters and stackable or nesting seating.
Miscellaneous Items - Laptop charging stations will be in Test Tool 218 and It Mission Prep 212. Each GFGI Crash cart in server rooms will have a small task chair added in the FFE package. The Classroom 221 will have training tables with folding nesting top, casters and wire way. Classroom task seating will be a task chair. The classroom will also have a smart podium, glass marker boards and video walls. Cell phone and laptop/tablet storage will be added at the main lobby and the east stair entrance.
End of Chapter
FY19 CYBERSPACE TEST GROUP FACILITY W9127820R0057
EGLIN AFB, FLORIDA MEF19017
SECTION 12 59 00
SYSTEMS FURNITURE
08/17
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI)
ANSI Z97.1 (2015) Safety Glazing Materials Used in Buildings - Safety Performance Specifications and Methods of Test
AMERICAN SOCIETY OF HEATING, REFRIGERATING AND AIR-CONDITIONING
ENGINEERS (ASHRAE)
ASHRAE 90.1 - IP (2016; ERTA 1-4 2017; INT 1-2 2017) Energy Standard for Buildings Except Low-Rise Residential Buildings
ASTM INTERNATIONAL (ASTM)
ASTM C1048 (2018) Standard Specification for Heat-Strengthened and Fully Tempered Flat Glass
ASTM C423 (2009a) Sound Absorption and Sound Absorption Coefficients by the Reverberation Room Method
ASTM E290 (2014) Bend Testing of Material for Ductility
ASTM E84 (2018a) Standard Test Method for Surface Burning Characteristics of Building Materials
BIFMA INTERNATIONAL (BIFMA)
ANSI/BIFMA M7.1 (2011; R 2016) Test Method for Determining VOC Emissions from Office Furniture Systems, Components and Seating
ANSI/BIFMA X5.5 (2014) American National Standards For Office Furnishings -Desk Products
ANSI/BIFMA X5.6 (2016) American National Standards For Office Furnishings -Panel Systems
SECTION 12 59 00 Page 1
NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA)
NEMA WD 1 (1999; R 2015) Standard for General Color Requirements for Wiring Devices
NEMA WD 6 (2016) Wiring Devices Dimensions Specifications
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)
NFPA 101 (2018; TIA 18-1; TIA 18-2; TIA 18-3) Life Safety Code
NFPA 265 (2015) Standard Methods of Fire Tests for Evaluating Room Fire Growth Contribution of Textile Coverings on Full Height Panels and Walls
NFPA 70 (2017) National Electrical Code
SCIENTIFIC CERTIFICATION SYSTEMS (SCS)
SCS SCS Global Services (SCS) Indoor Advantage
TELECOMMUNICATIONS INDUSTRY ASSOCIATION (TIA)
TIA-568-C.2 (2009; Errata 2010; Add 2 2014; Add 1 2016) Balanced Twisted-Pair Telecommunications Cabling and Components Standards
TIA-569 (2015d) Commercial Building Standard for Telecommunications Pathways and Spaces
U.S. NATIONAL ARCHIVES AND RECORDS ADMINISTRATION (NARA)
36 CFR 1191 Americans with Disabilities Act (ADA) Accessibility Guidelines for Buildings and Facilities; Architectural Barriers Act (ABA) Accessibility Guidelines
UNDERWRITERS LABORATORIES (UL)
UL 1286 (2008; Reprint Jan 2018) Office Furnishings
UL 2818 (2013) GREENGUARD Certification Program For Chemical Emissions For Building Materials, Finishes And Furnishings
UL 723 (2018) UL Standard for Safety Test for Surface Burning Characteristics of Building Materials
1.2 SUBMITTALS
Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are for Contractor Quality Control approval. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. Submit the
SECTION 12 59 00 Page 2 following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:
SD-02 Shop Drawings
Detail Drawings; G
SD-03 Product Data
Warranty; G
Workstations
Power and Communications
Communications
SD-04 Samples
Workstations; G
Samples
SD-06 Test Reports
Selected Components; G
Panel Acoustics; G
Fire Safety; G
Electrical System; G
SD-07 Certificates
Workstations
Indoor Air Quality
SD-08 Manufacturer's Instructions
SD-10 Operation and Maintenance Data
Assembly Manuals; G
Maintenance Manuals; G
Cleaning; G
Electrical System; G
Maintenance Agreements
Installation; G
SD-11 Closeout Submittals
Certified Sustainably Harvested door panels; S
Energy Efficient Equipment; S
SECTION 12 59 00 Page 3
Reduced VOC's for Furniture; S
Recycled Content of Furniture; S
Bio-Based Content of Furniture; S
Indoor Air Quality for Office Furniture Systems and Seating; S
Recycled Content for system furniture components; S
1.3 CERTIFICATIONS
1.3.1 Indoor Air Quality Certifications
1.3.1.1 Office Furniture Systems and Seating
Provide products certified to meet indoor air quality requirements by UL 2818 (Greenguard) Gold, SCS Global Services Indoor Advantage Gold, ANSI/BIFMA M7.1 Certification or provide certification or validation by other third-party program that products meet the requirements of this Section. Provide current product certification documentation from certification body. Provide documentation that products are Level 2 certified as a minimum.
1.4 QUALITY ASSURANCE
1.4.1 General Safety
Provide workstation products free of rough or sharp edges. Provide panel supported components with a positive, integral locking device which secures components without the use of additional screws or clamps to prevent the components from being accidentally pulled or knocked off the panels.
1.4.2 Fire Safety
Components must meet requirements for flame spread and smoke development as specified by NFPA 101 except as follows. Conduct testing in accordance with either ASTM E84 or UL 723 on the entire assembled panel of the worst case (most combustible) combination of fabric and interior construction.
In addition, fabric must meet the requirements of NFPA 265. Do not exceed 25 for Class A for panel flame spread and 450 for Class A, B and C panel smoke development.
1.4.3 Electrical System
Task lights are required to be UL listed and installation of task lighting must meet the requirements of NFPA 70. The electrical system must meet the requirements of UL 1286. Submit three sets of electrical system manuals describing the functions, configuration, and maintenance of the electrical system (power , communications, data). This material may be included in the Assembly or Maintenance manuals at the Contractor's option.
1.4.4 Detail Drawings
Submit detail drawings showing communications, electronic data processing (EDP) and local area network (LAN); locations may be provided as a separate submittal from remaining workstation drawings. Provide drawing requirements, which are the furniture manufacturer's responsibility, as a
SECTION 12 59 00 Page 4 single submittal. Provide electronic drawings to the user for future re-configuration in the software package requested by the user. Include in the electronic drawings all modifications made during installation. As a minimum, submit the following:
a. Overall reference drawings: Drawings showing workstation locations and overall plan view within each floor in a scale of 1/8 inch = 1 foot.
Layouts must reflect field verified conditions and clearly illustrate the overall space planning concept and intent.
b. Installation drawings: Drawings showing workstations, panels, components, and plan view within each floor. Identify workstations by workstation type; submit drawings showing the proposed workstation installation at a scale of 1/4 inch = 1 foot, unless otherwise specified. Installation drawings must reflect field verified conditions.
c. Workstation elevations: Dimensioned workstation elevations showing each type of workstation with panel frame configurations and all components identified with manufacturer's catalog numbers. Draw elevations at 1/2 inch = 1 foot scale.
d. Panel drawings: Panel drawings showing locations and critical dimensions from finished face of walls, columns, panels, including clearances and aisle widths. Key assemblies to a legend which includes width, height, configuration and composition of frame covers finishes and fabrics (if different selections exist within a project), power or nonpower, connectors and wall mount hardware. Coordinate panel placement with location of electrical, voice/date LAN, SIPRNet, NIPERNet, mechanical and fire protection fixtures. Drawings must reflect field verified conditions.
e. Electrical drawings: Drawings showing power provisions including type and location of feeder components (service entry poles, base or ceiling feeds), activated power receptacles and other electrical components.
Wiring configuration (circuiting, switching, internal and external connections) identified and a legend provided as applicable. Identify which receptacles in typical furniture configurations will be connected to controlled building power circuits as applicable to meet ASHRAE 90.1 - IPASHRAE 90.1 - SI requirements. Coordinate with electrical drawings.
f. Wire management capacity drawings.
g. Communication drawings showing telephone provisions: Drawings indicating the type and location of feeder components and communications jacks with wiring configuration identified where applicable.
h. Communication drawings showing electronic data processing provisions:
Drawings indicating the type and location of feeder components, communications jacks, or accessories with wiring configuration identified where applicable.
i. Communication drawings showing local area network provisions: Drawings indicating the type and location of feeder components and data jacks with extra ports for future expansion with wiring configuration identified where applicable.
SECTION 12 59 00 Page 5
j. Communications drawings indicating the TIA-568-C.2 pin/pair assignment that will be used for communications outlet as coordinated with the COR.
k. Reflected ceiling plan for projects specified with power poles.
l. Drawings indicating cabling is protected at all transition points, and that metallic separation is provided between telecommunication and power wiring in the utility columns and systems furniture track in accordance with TIA-569 and NFPA 70.
1.5 DELIVERY, STORAGE, AND HANDLING
Deliver components to the jobsite in the manufacturer's original packaging with the brand, item identification, and project reference clearly marked.
Remove furniture from packaging and store in an unoccupied, dry location that is ventilated. Storage shall be free from dirt and dust, water, and other contaminants, and in a manner that permits easy access for inspection and handling.
1.6 WARRANTY
Warrant the systems furniture for a minimum period of lifetime with the following exceptions: fabrics and other covering materials, and paper handling products for 3 years, LED drivers/power supplies for 5 years, and electromagnetic ballasts for 3 years. Warranties must be signed by the authorized representative of the manufacturer. Present warranties, accompanied by document authenticating the signer as an authorized representative of the guarantor, to the Contracting Officer upon the completion of the project. Guarantee that the workstation products and installation are free from any defects in material and workmanship from the date of delivery. Submit two copies of the warranty.
PART 2 PRODUCTS
2.1 MATERIALS
Provide System Furniture Components with a minimum of 55 percent recycled content. Provide data identifying percentage of recycled content for system furniture components.
Provide certification of indoor air quality for Office Furniture Systems and Seating.
2.2 PRODUCT SUSTAINABILITY CRITERIA
For products in this section, where applicable and to extent allowed by performance criteria, provide and document the following:
2.2.1 Energy Efficient Equipment
Coordinate requirement for energy efficient equipment, such as lighting, and provide documentation.
2.2.2 Reduced VOC's for Furniture
Coordinate requirement for reduced VOC requirements for furniture and provide documentation.
SECTION 12 59 00 Page 6
2.2.3 Recycled Content of Furniture
Coordinate requirement for recycled content for furniture and provide documentation.
2.1.4 Bio-Based Content of Furniture
Coordinate requirement for biobased content for furniture and provide documentation.
2.3 SYSTEM DESCRIPTION
2.3.1 Workstations
This specification establishes the minimum requirements for the acquisition and installation of a complete and usable system of workstations composed of panels, freestanding work surfaces or base units, supporting components, electrical hardware, communications, special electrical features, and accessories. Provide workstation requirements and configurations in accordance with the furniture layout and typical workstation types shown in drawings and specified herein. Provide components and hardware from a single manufacturer that are standard products as shown in the most recent published price lists or amendments. Proposed product must be part of the manufacturer's current line with no intent to discontinue within two years. Submit complete listing of part/model numbers for all components to be provided, including names and codes of components referenced on updated drawings. Provide electrical components from a single manufacturer to the extent practicable (different types of components may be of different manufacturers, but all units of a given component must be from a single source). Conformance with NFPA 70, UL 1286, NFPA 101, and 36 CFR 1191 (height and ADA pulls) is required. Coordinate the work of this section with that to be performed under other sections. This specification may include items which are not manufactured by the furniture manufacturer;
provide any such items under this section. Submit two complete sets of certificates attesting that the proposed workstation meets specified requirements. Date the certificate after the award of the contract, include the name of the project, and list specific requirements being certified.
2.3.2 Samples
Submit samples as required to obtain final approval. The Government reserves the right to reject any finish samples that do not satisfy the technical or color requirements. Work can not proceed without sample approval in writing from the Contracting Officer. Submit four sets of the finish samples listed below:
a. Panel, tackboard and overhead door fabric. Minimum 6 by 6 inches with label designating the manufacturer, pattern, color, fiber content, fabric width, fabric weight, fire rating, and use (panel and/or tackboard).
b. Workstation component finishes. Minimum 2-1/2 by 3 inches with label designating the manufacturer, material composition, thickness, color, and finish.
c. Personal Task lights (Not overhead task lights).
d. Panel glazing. Glazing samples with label designating the material and
SECTION 12 59 00 Page 7 safety ratings.
2.3.3 Performance Requirements
Panels, frames and frame covers, connection system, work surfaces, pedestals, shelf units, overhead door cabinets, lateral files, locks, accessories, and miscellaneous hardware must meet testing as specified.
ISO 9001 certified manufacturers may perform in-house testing.
Manufacturers not ISO 9001 qualified will be required to produce testing by an independent testing laboratory. Component specific requirements are listed in appropriate paragraphs.
2.3.3.1 Selected Components
Workstation conformance to ANSI/BIFMA X5.5 and ANSI/BIFMA X5.6 is required with the following exceptions: Panels, or panel supported components conformance to ANSI/BIFMA X5.6 is required. Representative items will be selected for testing based on worst case situations (i.e., the deepest and widest work surface or shelf). Perform the keyboard drawer or shelf test applying a 50 lb load to the center of the keyboard shelf for a period of 5 minutes. Any loosening of attachments or damage to the operation of the drawer or shelf will be cause for rejection.
2.3.3.2 Panel Acoustics
Provide high acoustic panels with a minimum noise reduction coefficient (NRC) of 0.80 when tested in accordance with ASTM C423 and a minimum sound transfer coefficient (STC) of 26 when tested in accordance with ASTM E290.
Conduct the test on the entire assembled panel, full face area (the complete core, adhesive, decorative fabric, frame and joining components).
2.3.3.3 Panel Glazing
Tempered glass must conform to ANSI Z97.1 and ASTM C1048, Kind FT, Condition A, Type I, Class 1 Transparent.
2.3.4 Pattern and Color
Provide pattern and color of finishes and fabrics for panel systems, components, and trim in accordance with Section 09 06 00 SCHEDULES FOR FINISHES as shown on the order data sheets.
2.4 SYSTEMS FURNITURE
2.4.1 Panel System Components
Supply aaccessories and appurtenances for a completely finished panel assembly with the system. Provide a system capable of structurally supporting cantilevered work surfaces, shelves, files, overhead cabinets, and other components in the configurations shown on the drawings plus more than one fully loaded component per panel per side. Provide panels that are tackable or capable of accommodating fabric covered tackboards, acoustical, stackable with a system capable of lowering or raising the overall panel assembly height at horizontal connections by removing or adding panel-frames on-site without disturbing adjacent panel components, segmented as designated on the drawings. Segments will be field removable from both sides of the panel. Provide adjustment of the worksurface at a minimum, within 7 inch range, from 28 inches - 35 inches (to top of surface). Provide a spine wall system where electrical and data management
SECTION 12 59 00 Page 8 will be easily accessible by removable wall covers that can be removed while workstation components are still attached. Provide a panel system that is available in a variety of nominal widths and heights as designated on the drawings. Measure heights from the finished floor to the top of the panel. Supply powered and nonpowered panels that are compatible in height. Coordinate panel heights with the HVAC and electrical designs.
Minimum panel thickness is 3 inches thick. System to have 100 percent off-modular capability with no defacement of any element caused by components when used in an off-modular application. Unique panel frames must not be required for off modular connections. Submit three sets of Assembly Manuals describing assembly and reconfiguration procedures.
2.4.2 Panel Finishes
Provide panels in the following options: safety glazed, open frame, tackable fabric, acoustical fabric, wood veneer, marker surface, paint, slat tile. Frame covers may have different options on either side of the frame. Exposed panel trim to have a factory baked enamel or epoxy powder finish. Filler trim will either match the panel trim or be fabric covered to match the panel fabric. Provide each fabric-faced panel with a seamless width of fabric stretched over the entire face of the panel. The fabric color throughout the installation must be consistent. Attach the fabric securely and continuously along the entire perimeter of the panel and allow for easy removal and replacement in the field (with the exception of curved panels). Fabric must be factory installed with panel fabric content.
2.4.3 Raceways
Provide metal raceways and covers as an integral part of the panel whether powered or nonpowered. Magnet held base covers will not be accepted.
2.4.4 Leveling Glides
Provide precise alignment of adjacent panels and include leveling glides to compensate for uneven floors. Provide quantity and location of leveling glides as recommended by the manufacturer. A minimum 1 inch adjustment range is required.
2.4.5 Connection System
Provide connectors which accommodate a variety of configurations as indicated on the drawings to include: a straight line connection of 2 panels (180 degrees), corner connection of 2 panels (90 degrees), T connection of 3 panels (90 degrees), cross connection of 4 panels (all 90 degrees). Provide tight connections with continuous visual and acoustical seals. Painted metal finish connections are required to match system.
Provide connector system that allows removal of a single panel within a typical workstation configuration, without requiring disassembly of the workstation or removal of adjacent panels. Provide for connection of similar or dissimilar heights to include trim pieces to finish the exposed edge. Right angle (90 degree) connections between panels must not interfere with the capability to hang work surfaces and other components on any adjacent panel. Provide, as required, the continuation of electrical and communications wiring within workstations and from workstation to workstation. Filler posts must be level with the top rail.
2.4.6 Wall Mounted Panels
Use wall-mount components when it is necessary to attach panels or vertical
SECTION 12 59 00 Page 9 panel-frame assemblies to the building walls. Provide structural support for wall panels as required. Panels and other systems furniture components are not be wall mounted unless they are included in the original design.
2.4.7 Glazed Panel Inserts
Provide safety glass glazed panel inserts in accordance with ANSI Z97.1 and ASTM C1048. Acrylic glazing will not be accepted.
2.5 WORK SURFACES
2.5.1 Construction
Construct work surfaces to prevent warpage. Fully support work surfaces from the panels or support jointly by the panels and supplemental legs, pedestals, or furniture end panels where indicated on drawings. Use supplemental end supports only under work surfaces when the work station configuration does not permit full support by the panels. Use metal support brackets to support work surfaces from the panels, provide metal-to-metal fitting to the vertical uprights of the panels, vertically adjustable, to lock the work surfaces in place without panel modifications. Support work surfaces with legs, pedestals, or furniture end panels. Abutting work surfaces must line up closely and be at equal heights when used in side-by-side configurations in order to provide a continuous and level work surface. Provide work surfaces in sizes and configurations shown on the drawings. Provide work surfaces in nominal depths of 24 inches, and 30 inches, nominal lengths from 24 to 96 inches, and a nominal thickness from 1 to 1-3/4 inches. Provide height adjustable work surfaces from 25 to 52 inches above the finished floor with an electrical control. Provide corner, peninsula, and counter/transaction work surfaces as shown on the drawings and include hardware necessary to provide firm and rigid support. Work surfaces must have 100 percent off-modular capability with no defacement of any element caused by components when used in an off-modular application.
2.5.2 Finishes
Provide work surfaces with a finished top surface of high pressure plastic laminate, and a smoothly finished underside. The work surface must not be damaged by ordinary household solvents, acids, alcohols, or salt solutions. Provide metal support brackets that match the color and finish of trim. Provide PVC or ABS edges.
2.6 PEDESTALS
Provide drawer configurations and pedestal height as shown on the drawings. Provide the deepest possible pedestal for each work surface size specified. Free standing mobile pedestals to include an attached upholstered seat cushion, a handle for moving, and casters. Mobile pedestals must be load bearing and equipped with counterbalance as standard. Provide appropriate height of mobile pedestal so it can be stored under a standard height worksurface.
2.6.1 Construction
Provide pedestals and drawers of steel construction with the exception of drawer fronts. Securely attach drawer faces to the drawer front.
SECTION 12 59 00 Page 10
2.6.2 Finishes
Provide a factory baked enamel finish or powder coated for steel surfaces.
Provide plastic laminate drawer fronts.
2.6.3 Drawer Requirements
Design pedestals to protect wires from being damaged by drawer operation.
Provide pedestals that are support work surfaces,. Drawers must stay securely closed when in the closed position and provide each drawer with a safety catch to prevent accidental removal when fully open. File drawers to be provided with full extension ball bearing drawer slides or rack and pinion suspension. File drawers to be provided with hanging folder frames or rails and capable of hanging side-to-side or front-to-back. Provide dividers with vertical files. Provide box drawers with pencil trays.
2.7 STORAGE
Provide storage units in the sizes and configurations shown on the drawings. Depth to accommodate a standard three ring binder. Panel attached storage is required to have 100 percent off-modular compatibility with no defacement of any element caused by components when used in an off-modular application. Provide wood veneer fronts.
2.7.1 Shelf Unit Construction
Provide metal construction shelf pan with formed edges. Provide shelf supporting end panels of metal, high density particle board, molded phenolic resin, or molded melamine. Provide relocatable shelf dividers with shelf units.
2.7.2 Overhead Cabinet Construction
Provide metal construction overhead cabinets. Provide doors with a suspension system. Provide sliding doors on overheads. Overhead cabinet must be ADA accessible.
2.7.3 Lateral File, Vertical File and Book Case Construction
Provide units and file fronts, top and end panels of steel construction.
File drawers to be provided with full extension ball bearing drawer slides or rack and pinion suspension. File drawers to be provided with hanging folder frames or rails and capable of hanging side-to-side or front-to-back. Provide dividers with vertical files.
2.7.4 Personal Storage Tower Construction
Provide personal storage tower and components of steel construction.
Height of the unit to be the same height as the surrounding panels. The personal storage tower will include one full height wardrobe unit with coat rod, two file drawers, bookcase with two adjustable shelves, and hinged lockable doors. Fronts must be plastic laminate.
2.7.5 Finish
Provide a factory baked enamel or epoxy powder coat finish for shelves, dividers and top dust cover. Provide either a factory baked enamel, epoxy powder coat or laminate finish for shelf supporting end panels. Shelf bottom is required to match end panel color. Provide metal doors with an
SECTION 12 59 00 Page 11 exterior finish of factory baked enamel and an interior finish of factory baked enamel or epoxy powder coat. Provide a factory baked enamel finish or epoxy powder coat on metal drawers. Provide a plastic laminate surface on overhead cabinets, pedestals, towers, and lateral files.
2.8 ACCESSORIES
2.8.1 Coat Hook
Provide one mounted coat hook per workstation.
2.8.2 Keyboard Tray
Provide work surfaces that are capable of accepting an articulating keyboard in locations as shown on the drawings. The keyboard tray must be capable of fully recessing under the work surface and extending to give the user full access to the keyboard. Provide height adjustability, 180-degree swing side travel rotation and negative tilting capability. Include a wrist support and a mouse pad at the same level as the keyboard tray to accommodate either right or left-handed users.
2.8.3 Erasable Marker Boards
Provide marker boards with a white writing surface that can be easily written on and erased and unaffected by common marker board cleaning/conditioning agents. Include a storage tray and minimum two markers with the markerboard. Size and location as shown on the drawings.
2.8.4 Paper Management Unit
Provide slatwall mounted paper management units as indicated for each workstation. Construct these units of coated steel or injection molded plastic to accommodate either legal or letter size lengths. Provide as a minimum utensil storge, 2 flat letter trays, one tackstrip.
2.8.5 CPU Holder
Provide a mounting to support the computer hard drive. Desk top and floor locations are not acceptable.
2.8.6 Signage
Provide panel mounted signage composed, at a minimum, of aluminum frame, back panel, clear plastic cover, and hanging device. Provide signage approximately 3 by 8 inches and capable of receiving a replaceable standard white paper insert. Match text type. Provide software for creating text in PC computers for owner production of replacement paper inserts after project completion.
2.8.7 Slat Tile
Provide slat tile with channels to accommodate attachments such as monitor arm, task light and organizer accessories. Provide maximum slat tile height and a length as shown on the drawings. Slat tile must be integral to the panel and not attached to the surface of the panel.
2.9 MISCELLANEOUS HARDWARE
Provide brackets, supports, hangers, clips, panel supported legs, SECTION 12 59 00 Page 12 connectors, adjustable feet, cover plates, stabilizers, and other miscellaneous hardware that contribute to a complete and operable furniture system.
2.10 LOCKS AND KEYING
Provide overhead cabinets, vertical files, personal storage towers, pedestals and lateral files with keyed locks, unless otherwise noted.
Provide field changeable lock cylinders with a minimum of 100 different key options. Key each workstation individually, and key locks alike within a workstation. Provide lockable drawers within a pedestal either by a central lock that controls all pedestals under one work surface or an individual keyed lock in each pedestal. Key alike central file and storage units which are grouped together but are not a part of a workstation unless otherwise specified. Provide two keys for each lock or two keys per workstation when keyed alike, and provide three master keys per area as indicated. Number keys and lock cylinders for ease of replacement. Clearly label locks with a key number, except for those manufacturers who have removable format locks.
2.11 POWER AND COMMUNICATIONS
Provide both powered and nonpowered panels with base raceways capable of distributing power circuits, communication cables and data lines. Provide nonpowered bases that are capable of easy field conversion to powered base without requiring the panel to be dismantled or removed from the workstation. Provide panels able to support lay-in cabling and having a large capacity for power and data. Provide ample space for storing excess wires and fiber optic cables in the interior of the spine wall frame.
Provide easy access to power and data systems in the spine wall without having to move return panels or components. Provide the ability for the spine wall system to supply power to a wall-attached panel system and/or an adjacent desk system. System must meet the requirements of UL 1286 and NFPA 70, Article 605. Provide conductors with 20 amp, #12 AWG wires (unless indicated otherwise) or the equivalent in the bus configuration. A single circuit must not serve more than two (2) cubicles or workstations under any circumstances. The label or listing of Underwriter's Laboratories, Inc. will be accepted as evidence that the material or equipment conforms to the applicable standards of that agency. Electrical work not addressed in this section must conform to the requirements of Section 26 20 00 INTERIOR DISTRIBUTION SYSTEM.
2.11.1 Panel Raceways
Provide panels that have hinged or removable covers that permit easy access to the raceway when required but are securely mounted and cannot be accidentally dislodged under normal conditions. Place raceways in locations such as the base, beltline, and below and above the beltline.
The raceway must not extend past either panel face by more than 1/2 inch.
Provide metal covers which attach securely to the raceway as required and match the finish and color of the panel trim.