AM01 DRAWINGS.pdf
PDF 13 MB Posted
- Attached to
- Cyberspace Test Group Facility, Eglin AFB, FL Federal contract opportunity
- Solicitation number
- W9127820R0057
About this file
This document provides details for a federal contract opportunity for construction services. The solicitation is for the construction of a new Cyberspace Test Group Facility at Eglin Air Force Base in Florida. The 52,003 square foot facility will include a multi-level sensitive compartmented information facility utilizing conventional design and construction methods. It will have a concrete foundation, split-faced concrete block construction over a steel frame, and a sloped standing seam metal roof. The facility will also include fire suppression systems, all utilities, pavements, communications, site improvements, and associated support facilities. The solicitation was issued by the Department of the Army Corps of Engineers Engineering District Mobile. The opportunity closing date and award date are not specified in the document.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| W9127820R0057 JA_Redacted.pdf | ||
| AM05.pdf | ||
| AM05 DRAWINGS.pdf | ||
| AM04.pdf | ||
| AM03 DRAWINGS.pdf | ||
| AM03.pdf | ||
| AM02 DRAWINGS.pdf | ||
| AM02.pdf | ||
| AM01.pdf | ||
| Site visit sign in sheet.pdf | ||
| VOL1.PDF | ||
| VOL6.PDF | ||
| VOL3.PDF | ||
| VOL4.PDF | ||
| RTA DRAWINGS VOL1.pdf | ||
| VOL5.PDF | ||
| VOL2.PDF | ||
| EM 385-1-1.pdf | ||
| RTA DRAWINGS VOL2 .pdf |
Show all 19
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
US Army Corps of Engineers
MOBILE DISTRICT
109 SAINT JOSEPH STREET
MOBILE AL 36602
CYBERSPACE TEST GROUP FACILITY
EGLIN AIR FORCE BASE, FLORIDA
OKALOOSA COUNTY
JUNE 2020
MOBILE DISTRICT PROJECT CODE: MEF19017
RFP NUMBER: W9127820R0057
AMENDMENT NO. 0001
A
SHEET
IDENTIFICATION
US Army Corps of
Engineers ®
Mobile District
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D E
S
IG
N E
D B
Y
B U
L L
O C
K T
IC
E
A S
S O
C
IA
T E
S
E
C
E R
V A
N T
E S
S T
R E
E T
P E
N S
A C
O L
A F
L O
R
ID
A
2 3 4 5
B
C
D
D R
A W
N B
Y
S B
M T
B Y
P L
O T
S C
A L
E
S
IZ
E
C K
D B
Y
P L
O T
D A
T E
D A
T E
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
P R
O J E
C T
N U
M B
E R
F
IL
E N
A M
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
:1 x
M O
B
IL
E D
IS
T
R
IC
T
M O
B
IL
E A
L A
B A
M A
M E
F
M
A Y
W
R
AMENDMENT 0001
/2
/2
:1
:2
P
M
C Y
B E
R S
P A
C E
T E
S T
G R
O U
P F
A C
IL
IT
Y
E G
L
IN
A F
B
F L
O R
ID
A
G-003
IN
D
E X
O F
D R
A W
IN
G
S
B
M A
G G
IO
R
E
T
W A
L L
IS
B
M
A G
G
IO
R E
B T
A
M
A Y
M E
F
G
FTFA 16-3007
INDEX OF DRAWINGS - VOLUME 2 OF 2
SHEET
NUMBER SHEET NAME
T-016 ENLARGED NEW MAINTENANCE HOLE 72 AND EX MH 73
T-017 ENLARGED NEW MAINTENANCE HOLE 71
T-018 ENLARGED BUILDING 90 MAINTENANCE HOLES
T-019 NON-CORE SERVICES COMMUNICATIONS SITE PLAN - BID OPTION 3
T-020 TELECOM SITE DETAILS
T-021 TELECOM SITE DETAILS
T-111 OVERALL FIRST FLOOR CONDUIT PATHWAY PLAN
T-112 OVERALL FIRST FLOOR OVERHEAD/ABOVE CEILING PATHWAY PLAN
T-113 OVERALL FIRST FLOOR BELOW FLOOR PATHWAY PLAN
T-114 OVERALL FIRST FLOOR CABLING DISTRIBUTION PLAN
T-115 ENLARGED FIRST FLOOR PLAN WEST
T-116 ENLARGED FIRST FLOOR PLAN EAST
T-121 OVERALL SECOND FLOOR CONDUIT PATHWAY PLAN
T-122 OVERALL SECOND FLOOR OVERHEAD/ ABOVE CEILING PATHWAY PLAN
T-123 OVERALL SECOND FLOOR BELOW FLOOR PATHWAY PLAN
T-124 OVERALL SECOND FLOOR CABLING DISTRIBUTION PLAN
T-125 ENLARGED SECOND FLOOR PLAN WEST
T-126 ENLARGED SECOND FLOOR PLAN EAST
T-201 TELECOM GROUNDING DETAILS
T-202 TELECOM OUTLET DETAILS
T-203 TELECOM OUTLET DETAILS
T-204 TELECOM DETAILS
T-205 TELECOM DETAILS
T-206 PROTECTIVE DISTRIBTION SYSTEM (PDS) DETAILS
T-207 PROTECTIVE DISTRIBTION SYSTEM (PDS) DETAILS
T-208 TELECOM MOUNTING DETAILS
T-301 CORE BACKBONE SINGLE LINE DIAGRAMS
T-302 NON-CORE BACKBONE AND UNCLASS SINGLE LINE DIAGRAMS
T-303 CLASS SIPR & NON CORE SINGLE LINE DIAGRAMS
T-304 NON-CORE SINGLE LINE DIAGRAMS
T-305 NON-CORE AND UNCLASS SINGLE LINE DIAGRAMS
T-306 LAB CLOSED NETWORKS SINGLE LINE DIAGAMS
T-307 OTHER, COMMERCIAL, AND LAB CLOSED NETWORK SINGLE LINE DIAGRAMS
T-308 CATV AND PA SINGLE LINE DIAGRAMS
T-401 TELECOM ENLARGED SERVER ROOM 114
T-402 TELECOM ENLARGED STORAGE ROOM 129
T-403 TELECOM ENLARGED ATL ANALYSIS ROOM 138
T-404 TELECOM ENLARGED C/EW ANALYSIS ROOM 140
T-405 TELECOM ENLARGED COMM ROOM 141 & AC SERVER ROOM 148
T-406 TELECOM ENLARGED COMM ROOM 152
T-407 TELECOM ENLARGED IDE SERVER ROOM 202
T-408 TELECOM ENLARGED 96 CTG. SEC. COMM ROOM 214
T-409 TELECOM ENLARGED COMM ROOM 234 & 240
T-501 TELECOM RACK ELEVATIONS- SERVER ROOM 114 & STORAGE ROOM 129
T-502 TELECOM RACK ELEVATIONS - ATL ANALYSIS ROOM 138
T-503 TELECOM RACK ELEVATIONS - C/EW ANALYSIS ROOM 140
T-504 TELECOM RACK ELEVATIONS - COMM. ROOM 141 & ACR SERVER ROOM 148
T-505 TELECOM RACK ELEVATIONS - COMM ROOM 152
T-506 TELECOM RACK ELEVATIONS - IDE SERVER ROOM 202
T-507 TELECOM RACK ELEVATIONS - ITS STORAGE ROOM 211 & 96 CTG. SEC, COMM ROOM 214
T-508 TELECOM RACK ELEVATIONS - COMM ROOM 234
T-509 TELECOM RACK ELEVATIONS - COMM. ROOM 240
TA001 AUDIO VISUAL LEGEND
TA111 AUDIO VISUAL FIRST FLOOR PLAN WEST
TA112 AUDIO VISUAL FIRST FLOOR PLAN EAST
TA121 AUDIO VISUAL SECOND FLOOR PLAN WEST
TA122 AUDIO VISUAL SECOND FLOOR PLAN EAST
TA201 AUDIO VISUAL DETAILS
TA301 AUDIO VISUAL DIAGRAMS
TY001 SECURITY LEGEND & NOTES
TY111 SECURITY FIRST FLOOR PLAN WEST
TY112 SECURITY FIRST FLOOR PLAN EAST
TY121 SECURITY SECOND FLOOR PLAN WEST
TY122 SECURITY SECOND FLOOR PLAN EAST
TY201 SECURITY DETAILS
TY202 SECURITY DOOR DETAILS
TY203 SECURITY DOOR DETAILS
TY204 SECURITY DOOR DETAILS
TY205 SECURITY DOOR DETAILS
TY301 SECURITY SINGLE LINE DIAGRAMS
TY302 SECURITY SINGLE LINE DIAGRAMS
INDEX OF DRAWINGS - VOLUME 2 OF 2
SHEET
NUMBER SHEET NAME
E-100 DEMO ELECTRICAL SITE PLAN
E-101 NEW WORK ELECTRICAL SITE PLAN
E-102 NEW WORK ELECTRICAL SITE LIGHTING PLAN
E-103 SITE LIGHTING DETAILS - BID OPTION 11
E-111 OVERALL FIRST FLOOR POWER PLAN & PATHWAYS
E-112 FIRST FLOOR POWER PLAN - WEST
E-113 FIRST FLOOR GROUNDING PLAN - WEST
E-114 FIRST FLOOR POWER PLAN - EAST
E-115 FIRST FLOOR GROUNDING PLAN - EAST
E-116 OVERALL SECOND FLOOR POWER PLAN
E-117 SECOND FLOOR POWER PLAN - WEST
E-118 SECOND FLOOR GROUNDING PLAN - WEST
E-119 SECOND FLOOR POWER PLAN - EAST
E-120 SECOND FLOOR GROUNDING PLAN - EAST
E-211 OVERALL FIRST FLOOR LIGHTING PLAN
E-212 FIRST FLOOR LIGHTING PLAN - WEST
E-213 FIRST FLOOR LIGHTING PLAN - EAST
E-214 OVERALL SECOND FLOOR LIGHTING PLAN
E-215 SECOND FLOOR LIGHTING PLAN - WEST
E-216 SECOND FLOOR LIGHTING PLAN - EAST
E-311 OVERALL FIRST FLOOR MECHANICAL POWER PLAN
E-312 FIRST FLOOR MECHANICAL POWER PLAN - WEST
E-313 FIRST FLOOR MECHANICAL POWER PLAN - EAST
E-314 OVERALL SECOND FLOOR MECHANICAL POWER PLAN
E-315 SECOND FLOOR MECHANICAL POWER PLAN - WEST
E-316 SECOND FLOOR MECHANICAL POWER PLAN - EAST
E-400 LIGHTNING PROTECTION PLAN
E-401 LIGHTNING PROTECTION DETAILS
E-500 DEV&RE LAB/THREAT DEVELOPMENT LAB ENLARGED 60Hz/00Hz & DC ROOM PLANS
E-501 CYBER/EW ENLARGED ROOM PLAN 60Hz
E-502 CYBER/EW ENLARGED ROOM PLAN 400Hz & DC
E-503 AVIONICS TEST LAB ENLARGED ROOM PLAN 60Hz
E-504 AVIONICS TEST LAB ENLARGED ROOM PLAN - 400Hz & DC
E-600 PANEL SCHEDULE INDEX
E-601 PANEL SCHEDULE
E-602 PANEL SCHEDULE
E-603 PANEL SCHEDULE
E-604 PANEL SCHEDULE
E-605 PANEL SCHEDULE
E-606 PANEL SCHEDULE
E-607 PANEL SCHEDULE
E-608 PANEL SCHEDULE
E-609 PANEL SCHEDULE
E-610 PANEL SCHEDULE
E-611 PANEL SCHEDULE
E-612 PANEL SCHEDULE
E-613 PANEL SCHEDULE
E-614 PANEL SCHEDULE
E-615 PANEL SCHEDULE
E-616 PANEL SCHEDULE
E-617 400Hz PANEL SCHEDULE
E-618 400Hz PANEL SCHEDULE
E-619 400Hz PANEL SCHEDULE
E-620 270VDC PANEL SCHEDULES
E-621 28VDC PANEL SCHEDULES
E-622 28VDC PANEL SCHEDULES
E-623 28VDC PANEL SCHEDULES
E-624 PANEL SCHEDULE
E-625 PANEL SCHEDULE
E-626 BUS DUCT PLUG SCHEDULES
E-627 BUS DUCT PLUG SCHEDULES
TELECOMMUNICATIONS
T-001 TELECOM LEGEND
T-002 GENERAL NOTES
T-003 TELECOM SITE NOTES
T-004 PARTIAL CORE SERVICES COMMUNICATIONS SITE PLAN
T-005 PARTIAL CORE SERVICES COMMUNICATIONS SITE PLAN
T-006 PARTIAL CORE SERVICES COMMUNICATIONS SITE PLAN
T-007 PARTIAL CORE SERVICES COMMUNICATIONS SITE PLAN
T-008 ENLARGED EXISTING MANHOLE 73 AREA
T-009 ENLARGED EXISTING MANHOLE 7C AREA
T-010 ENLARGED EXISTING MANHOLE 8C AND NEW MANHOLE 2E-1 AREA
T-011 ENLARGED EXISTING MANHOLE 2E AREA
T-012 ENLARGED EXISTING MANHOLE 2X AND 3X
T-013 ENLARGED EXISTING MANHOLE 17, 18, & 19
T-014 ENLARGED EXISTING MANHOLE 2B2
T-015 ENLARGED EXISTING MANHOLE 2B1
INDEX OF DRAWINGS - VOLUME 2 OF 2
SHEET
NUMBER SHEET NAME
FIRE PROTECTION
FA101 OVERALL FIRST FLOOR FIRE ALARM PLAN
FA102 PARTIAL FIRST FLOOR FIRE ALARM PLAN - WEST
FA103 PARTIAL FIRST FLOOR FIRE ALARM PLAN - EAST
FA104 OVERALL SECOND FLOOR FIRE ALARM PLAN
FA105 PARTIAL SECOND FLOOR FIRE ALARM PLAN - WEST
FA106 PARTIAL SECOND FLOOR FIRE ALARM PLAN - EAST
FA501 DETAILS - FIRE ALARM
FA502 FIRE ALARM SEQUENCE OF OPERATION
FX101 OVERALL FIRST FLOOR FIRE PROTECTION PLAN
FX102 PARTIAL FIRST FLOOR FIRE PROTECTION PLAN - WEST
FX103 PARTIAL FIRST FLOOR FIRE PROTECTION PLAN - EAST
FX104 OVERALL SECOND FLOOR FIRE PROTECTION PLAN
FX105 PARTIAL SECOND FLOOR FIRE PROTECTION PLAN - WEST
FX106 PARTIAL SECOND FLOOR FIRE PROTECTION PLAN - EAST
FX401 ENLARGED FIRE PUMP ROOM
FX501 DETAILS - FIRE PROTECTION
PLUMBING
P-001 PLUMBING LEGENDS, NOTES & ABBREVIATION
P-101 PARTIAL FIRST FLOOR PLAN WEST - PLUMBING BELOW SLAB
P-102 PARTIAL FIRST FLOOR PLAN EAST - PLUMBING BELOW SLAB
P-103 PARTIAL FIRST FLOOR PLAN WEST - PLUMBING ABOVE SLAB
P-104 PARTIAL FIRST FLOOR PLAN EAST - PLUMBING ABOVE SLAB
P-105 PARTIAL SECOND FLOOR PLAN WEST - PLUMBING BELOW SLAB
P-106 PARTIAL SECOND FLOOR PLAN EAST - PLUMBING BELOW SLAB
P-107 PARTIAL SECOND FLOOR PLAN WEST - PLUMBING ABOVE SLAB
P-108 PARTIAL SECOND FLOOR PLAN EAST - PLUMBING ABOVE SLAB
P-401 ENLARGED FIRST FLOOR PLAN - PLUMBING WASTE, VENT AND WATER
P-402 ENLARGED SECOND FLOOR PLAN - PLUMBING WASTE, VENT AND WATER
P-501 PLUMBING DETAILS-1
P-502 PLUMBING DETAILS-2
P-503 PLUMBING DETAILS-3
P-601 PLUMBING SCHEDULES-1
P-901 PLUMBING RISER EAST - WASTE AND VENT
P-902 PLUMBING RISER WEST - WASTE AND VENT
P-903 PLUMBING RISER - COMPRESSED AIR
P-904 PLUMBING RISER EAST - DOMESTIC WATER
P-905 PLUMBING RISER WEST - DOMESTIC WATER
MECHANICAL
M-001 HVAC LEGENDS, NOTES & ABBREVIATION
M-101 OVERALL FIRST FLOOR PLAN - HVAC
M-102 PARTIAL FIRST FLOOR PLAN - HVAC WEST
M-103 PARTIAL FIRST FLOOR PLAN - HVAC EAST
M-104 OVERALL SECOND FLOOR PLAN - HVAC
M-105 PARTIAL SECOND FLOOR PLAN - HVAC WEST
M-106 PARTIAL SECOND FLOOR PLAN - HVAC EAST
M-107 PARTIAL FIRST FLOOR PLAN - HVAC PIPING WEST
M-108 PARTIAL FIRST FLOOR PLAN - HVAC PIPING EAST
M-109 PARTIAL SECOND FLOOR PLAN - HVAC PIPING WEST
M-110 PARTIAL SECOND FLOOR PLAN - HVAC PIPING EAST
M-401 ENLARGED PLAN - HVAC
M-501 HVAC DETAILS-1
M-502 HVAC DETAILS-2
M-503 HVAC DETAILS-3
M-504 HVAC DETAILS-4
M-601 HVAC SCHEDULES-1
M-602 HVAC SCHEDULES-2
M-603 HVAC SCHEDULES-3
M-701 CHILLED WATER PIPING DIAGRAM - PRIMARY LOOP
M-702 CHILLED WATER PIPING DIAGRAM - SECONDARY LOOP
M-703 HVAC CONTROLS-1
M-704 HVAC CONTROLS-2
M-705 HVAC CONTROLS-3
ELECTRICAL
E-001 LEGEND AND ABBREVIATIONS
E-002 LIGHTING FIXTURE SCHEDULE
E-003 ELECTRICAL PRIMARY RISER
E-004 ELECTRICAL ONE-LINE DIAGRAM (277/480V) - BASE BID
E-005 BID OPTIONS ELECTRICAL ONE-LINE DIAGRAM (227/480V)
E-006 ELECTRICAL ONE-LINE DIAGRAM (120/280V)
E-007 400Hz, 28VDC, ONE LINE DIAGRAMS
E-008 GROUNDING SYSTEM RISER DIAGRAM
E-009 PENETRATION DETAILS
E-010 LIGHTING DETAILS
E-011 LIGHTING DETAILS
INDEX OF DRAWINGS THIS SHEET
INCLUDE VOLUME 2 DRAWINGS
A
M E
N D
M E
N T
/2
/2
WORK OF THIS CONTRACT INCLUDES THE CONSTRUCTION OF MULTIPLE SECURE AREAS IN ACCORDANCE WITH UFC 4-010-05 SENSITIVE COMPARTMENT INFORMATION FACILITIES PLANNING, DESIGN, CONSTRUCTION (1 FEB 2013, CHANGE 1 OCT 2013) AND TECHNICAL SPECIFICATIONS FOR THE CONSTRUCTION AND MANAGEMENT OF SENSITIVE COMPARTMENTED INFORMATION FACILITIES, VERSION 1.4 IC TECH SPEC-FOR ICD/ICS 705 (SEPTEMBER 28, 2017). THE RELATED BUILDING SYSTEMS AND ASSEMBLIES HAVE BEEN DESIGNED TO MEET THIS CRITERIA AND SHALL BE CONSTRUCTED AND INSTALLED BY THIS CONTRACT IN ACCORDANCE WITH THIS SAME CRITERIA. REFER TO SPECIFICATION SECTION 01 00 00 AND 01 11 00 FOR ADDITIONAL REQUIREMENTS. THE FOLLOWING PROVIDES ADDITIONAL GENERAL REQUIREMENTS AND DETAILED INFORMATION TO SUPPLEMENT THE DRAWING AND TECHNICAL SPECIFICATION REQUIREMENTS RELATED TO THE CONSTRUCTION OF THE SECURE AREAS OF THIS CONTRACT.
1. CONTRACTOR SHALL SCHEDULE AND COORDINATE THE SEQUENCE OF INSTALLATION OF ALL SECURE AREA PERIMETER WITH THE CONTRACTING OFFICER TECHNICAL REPRESENTATIVE (COTR) TO PROVIDE ADVANCE NOTIFICATION AND ACCESS TO BUILDING ASSEMBLIES AND SYSTEMS THAT ARE PART OF THE DESIGNATED SECURE AREA(S) FOR GOVERNMENT SECURITY INSPECTORS TO PERFORM REQUIRED INSPECTIONS, DOCUMENTATION AND TESTING DURING VARIOUS STAGES OF CONSTRUCTION OF SECURE AREA CONSTRUCTION BEFORE BEING CONCEALED BY OTHER WORK OF THIS CONTRACT. THESE ASSEMBLIES INCLUDE, BUT NOT LIMITED TO; SECURITY PERIMETER WALLS, FLOOR/CEILING, ROOF/CEILING, AND ALL PENETRATIONS THROUGH THE SECURE PERIMETER.
2. SECURITY STC RATED WALLS, FLOOR/CEILING, AND ROOF/CEILING ASSEMBLIES SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE TESTED ASSEMBLY IDENTIFIED ON THE DRAWINGS AS THE “BASIS OF DESIGN” (OR APPROVED EQUAL) AND OTHER ADDITIONAL REQUIREMENTS IDENTIFIED ON THE DRAWINGS AND SPECIFICATIONS THAT MAY NOT BE SPECIFICALLY ADDRESSED IN THE TEST DATA SUCH AS; SEALING OF THE ASSEMBLY PERIMETER AT JUNCTION WITH OTHER SOUND RATED AND NON-SOUND RATED ASSEMBLIES, SEALING ALL PENETRATIONS, AND MODIFICATIONS TO ENHANCE PHYSICAL SECURITY PERFORMANCE (IE: STUD GAGE AND
SPACING, ETC.).
3. WHERE INDICATED FOR CONSTRUCTION TO BE SEALED, SEALING SHALL BE ACCOMPLISHED USING ACOUSTICAL SEALANT TO FILL ALL GAPS, HOLES AND SPACES AT ALL JUNCTIONS, PERIMETER AND PENETRATIONS THROUGH THE SECURITY ASSEMBLIES (WALL, FLOOR, AND CEILING – 6 SIDED BOX). FIRE SEALANT AT FIRE RATED CONSTRUCTION CONDITIONS WHEN REQUIRED, OTHERWISE SHALL BE ACOUSTICAL SEALANT. ALL
OTHER MATERIALS ARE UNACCEPTABLE.
4. STC RATED ASSEMBLIES SHALL BE INSTALLED FOLLOWING MANUFACTURER’S INSTALLATION INSTRUCTIONS, REQUIREMENTS AND DETAILS FOR SOUND RATED AND FIRE RATED ASSEMBLIES.
5. STC RATED ASSEMBLIES IDENTIFIED ON THE DRAWINGS INDICATE “MINIMUM” STC RATINGS WHICH ARE THE REQUIRED MINIMUMS TO MEET PHYSICAL SECURITY STANDARDS, BUT HAVE BEEN DESIGNED USING HIGHER STC RATED ASSEMBLIES AS INDICATED ON THE DRAWINGS WITH TEST NUMBERS. THE CONTRACTOR SHALL CONSTRUCT THE STC RATED ASSEMBLIES TO MEET THE STATED “MINIMUM” STC RATING THAT WILL BE FIELD
TESTED BY THE GOVERNMENT TO VERIFY THE MINIMUM STC RATING IS ACHIEVED.
6. EVALUATION OF STC RATED ASSEMBLIES THAT ARE DIFFERENT FROM THE “BASIS OF DESIGN” STC ASSEMBLIES SHALL BE TESTED IN ACCORDANCE WITH ASTM E90 AND ASTM E413 TO ESTABLISH THE STC RATING OF THE
ASSEMBLY.
7. PROJECT INCLUDES WALLS THAT ARE COMPOSED OF SEVERAL WALL ASSEMBLY TYPES THAT REQUIRE THE CONTRACTOR TO SEQUENCE THE INSTALLATION WITH THE FOLLOWING ORDER OF PRECEDENCE FOR TERMINATIONS AT INTERSECTIONS AND PERIMETERS AND SEALING OF PENETRATIONS; FIRE, SOUND, AND NON-FIRE OR SOUND RATED ASSEMBLIES.
8. STC RATED DOOR ASSEMBLIES SHALL MEET SPECIFIED TESTING CRITERIA AND INSTALLED IN ACCORDANCE WITH THE TEST DATA AND MANUFACTURER’S INSTRUCTION AND CRITERIA.
9. ALL PENETRATIONS THROUGH SECURE AREA SECURITY WALLS AND STC RATED WALLS SHALL BE COMPLETELY SEALED ON BOTH SIDES OF THE PENETRATION WITH ACOUSTICAL SEALANT AT NON-FIRE RATED
CONDITIONS AND FIRE CAULK AT FIRE RATED ASSEMBLIES. PENETRATIONS INCLUDE BUT NOT LIMITED TO; CONDUITS, PIPING, DUCTWORK, RACEWAYS, STRUCTURAL COMPONENTS, ETC. IF SEALING OF PENETRATIONS THROUGH FIRE RATED ASSEMBLIES ONLY REQUIRES FIRE CAULKING ON ONE SIDE OF THE PENETRATION THE OTHER SIDE SHALL BE SEALED WITH ACOUSTICAL SEALANT.
10. SEAL BOTH SIDES OF THE STC RATED GYPSUM WALL BOARD AND METAL STUD PERIMETER WALLS WITH ACOUSTICAL SEALANT AT JUNCTURE WITH FLOOR SLAB, ADJACENT WALLS, STC FLOOR/CEILING AND STC ROOF/CEILING ASSEMBLIES. STC AND FIRE RATED WALL ASSEMBLIES SHALL EXTEND TO THE METAL FLOOR DECK OR ROOF DECK AND SEALED WITH FIRE SEALANT.
11. GYPSUM WALL BOARD / METAL STUD SECURITY WALL ASSEMBLY ADDITIONAL REQUIREMENTS:
A. METAL WALL STUDS, BOTTOM TRACK AND TOP TRACK SHALL BE MINIMUM 16 GAUGE STEEL. STUDS SHALL BE INSTALLED AT 16” O.C. MAXIMUM.
B. METAL WALL STUD FRAMING BOTTOM TRACK AND TOP TRACKS SHALL BE ATTACHED WITH ANCHORS AT 32” O.C. MAXIMUM (CLOSER IF REQUIRED BY TESTING) AND SET IN TWO ROWS OF CONTINUOUS
ACOUSTICAL SEALANT. COMPLETELY FILL VOIDS BETWEEN TOP TRACK AND DECK WITH FIRE SAFING MATERIAL OR NON-SHRINK GROUT.
C. ACOUSTIC INSULATION SHALL BE INSTALLED TIGHT BETWEEN METAL STUDS AND FASTENED IN A MANNER TO KEEP THE INSULATION FROM SLIDING DOWN LEAVING A VOID AT THE TOP OF THE WALL
ASSEMBLY.
12. GYPSUM WALL BOARD SHAFTWALL SECURITY WALL ASSEMBLY ADDITIONAL REQUIREMENTS:
A. METAL FRAMING SHALL BE MINIMUM 20 GAUGE STEEL (0.0329 INCH THICK BARE METAL).
B. BOTTOM TRACK AND TOP TRACK RUNNERS SHALL BE ATTACHED WITH ANCHORS AT 32” O.C. MAXIMUM (CLOSER IF REQUIRED BY TESTING) AND SET IN TWO ROWS OF CONTINUOUS ACOUSTICAL SEALANT
(FIRE CAULK IF A FIRE RATED ASSEMBLY). PROVIDE FIRE SAFING MATERIAL TO FILL VOIDS BETWEEN TRACK AND CORRUGATION OF DECK.
C. ACOUSTIC INSULATION SHALL BE INSTALLED TIGHT BETWEEN STUDS AND FASTENED IN A MANNER TO KEEP THE INSULATION FROM SLIDING DOWN LEAVING A VOID AT THE TOP OF THE WALL ASSEMBLY.
13. ALL WALL AND CEILING SURFACES THAT FORM THE SECURE AREA PERIMETER SHALL BE FINISHED, PAINTED TO PROVIDE A UNIFORM APPEARANCE, INCLUDING AT LOCATIONS BELOW ACCESS FLOORS AND ABOVE LAY-IN ACOUSTICAL CEILINGS. GYPSUM WALL BOARD SURFACES SHALL HAVE JOINTS TAPED, FINISHED AND PAINTED.
14. ALL WALLS AND CEILING SURFACES WITHIN THE SECURE AREA PERIMETER SHALL BE PAINTED, INCLUDING AT LOCATIONS BELOW ACCESS FLOORS AND ABOVE LAY-IN ACOUSTICAL CEILINGS. GYPSUM WALL BOARD
SURFACES SHALL HAVE JOINTS TAPED, FINISHED AND PAINTED.
15. UTILITIES AT SECURITY WALLS (SECURE AREAS A & B) - ALL ELECTRICAL SYSTEM PATHWAYS (CONDUITS AND BOXES), PIPING, AND OTHER BUILDING SYSTEMS SHALL BE SURFACE MOUNTED TO THE SECURITY WALL ASSEMBLY (DO NOT INSTALL WITHIN THE SECURITY WALL ASSEMBLY). WHERE ADDITIONAL GYPSUM BOARD / METAL STUD WALLS ("FRANGIBLE") ARE TO BE INSTALLED DIRECTLY OUT-BOARD OF THE SECURITY WALL ASSEMBLY, INSTALL CONDUITS, BOXES AND OTHER BUILDING SYSTEMS TO BE CONCEALED WITHIN THE OUTER FRANGIBLE WALL (UNLESS SHOWN OTHERWISE ON DRAWINGS). PAINT ALL SURFACE MOUNTED ITEMS.
16. UTILITIES AT SECURITY CEILING ASSEMBLIES - ALL ELECTRICAL AND COMMUNICATIONS SYSTEM PATHWAYS (CONDUITS AND BOXES), PIPING, AND OTHER BUILDING SYSTEMS SHALL ONLY BE SURFACE MOUNTED BELOW OR SUSPENDED BELOW THE STC SECURITY CEILING ASSEMBLY (DO NOT INSTALL WITHIN OR ABOVE THE SECURITY CEILING ASSEMBLY). THE ONLY ITEMS PERMITTED TO BE INSTALLED WITHIN THE STC SECURITY CEILING ASSEMBLY ARE LIMITED TO; STRUCTURAL FLOOR AND ROOF COMPONENTS, UTILITY SUSPENSION SYSTEM COMPONENTS (IE: UNI-STRUT) TO SUPPORT UTILITIES BELOW THE STC SECURITY CEILING. ALL PENETRATIONS THROUGH THE SECURITY CEILING ASSEMBLY SHALL BE COMPLETELY SEALED WITH ACOUSTICAL SEALANT.
17. SOUND ATTENUATION FOR SECURE AREA PERIMETER (FLOORS, WALLS, CEILINGS, DOORS, AND PENETRATIONS) - SOUND GROUP 4 (FIELD STC 50 (FSTC 50), MINIMUM. GOVERNMENT ACCREDITATION PROCESS WILL PERFORM FIELD TESTING TO VERIFY ACOUSTIC RATING IS ACHIEVED. CONTRACTOR TO PERFORM FIELD TESTING AND MAKE NECESSARY IMPROVEMENTS TO ACHIEVE THE REQUIRED MINIMUM FSTC RATING.
CONTRACTOR ACOUSTIC TESTING SHALL BE PERFORMED IN ACCORDANCE WITH ICD/ICS 705 CHAPTER 9 INSTRUMENTAL ACOUSTIC TESTS FOR SECURE AREA PERIMETER (FLOOR, WALLS, AND CEILING) AND PROVIDE TEST REPORT WITH RESULTS. THE GOVERNMENT WILL PERFORM ACOUSTIC TESTING INDEPENDENT OF THE CONTRACTORS ACOUSTIC TESTING. CONTRACTOR SHALL MAKE NECESSARY CHANGES OR IMPROVEMENTS TO THE INSTALLED WORK TO REMEDY AREAS OR COMPONENTS OF THE NEW CONSTRUCTION IDENTIFIED BY THE CONTRACTOR TESTING AND GOVERNMENT TESTING BEING DEFICIENT.
SECURE AREA CONSTRUCTION - GENERAL NOTES - SECURE USE AREAS A & B
A
SHEET
IDENTIFICATION
US Army Corps of
Engineers ®
Mobile District
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D E
S
IG
N E
D B
Y
B U
L L
O C
K T
IC
E
A S
S O
C
IA
T E
S
E
C
E R
V A
N T
E S
S T
R E
E T
P E
N S
A C
O L
A F
L O
R
ID
A
2 3 4 5
B
C
D
D R
A W
N B
Y
S B
M T
B Y
P L
O T
S C
A L
E
S
IZ
E
C K
D B
Y
P L
O T
D A
T E
D A
T E
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
P R
O J E
C T
N U
M B
E R
F
IL
E N
A M
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
:1 x
M O
B
IL
E D
IS
T
R
IC
T
M O
B
IL
E A
L A
B A
M A
M E
F
M
A Y
W
R
AMENDMENT 0001
/2
/2
:5
:4
P
M
C Y
B E
R S
P A
C E
T E
S T
G R
O U
P F
A C
IL
IT
Y
E G
L
IN
A F
B
F L
O R
ID
A
G-004
S E
C U
R
IT
Y A
N D
S T
C C
O N
S T
R U
C T
IO
N
N O
T E
S
B
M A
G G
IO
R
E
R .F
IV
E
A S
H B
M
A G
G
IO
R E
B T
A
M
A Y
M E
F
G
FTFA 16-3007
A
M E
N D
M E
N T
/2
/2
BL
BL
BL
BLBL
BL
BL BL
BLBL
BLBL
BL
BL
BL
BL
BLBL
BL
BL
BL BL
BLBL
BL
BL
BL
BL
BL
BL
CRK
CRK
CRK
C R
K
C R
K
C R
K
C R
K
C R
K
C R
K
CRK
CRK
CRK
C R
K
CRKH
S
S H
S S
H S
S H
S S
C A
M C
C T
V ,E
X T
IDS
C R
K
C R
K
H S
S
KS
MON
S
CAM
S
K S
C R
K
KS
KS
M O
N S
K S
M O
N S
HSS
MD
MD
K S
HSS
HSS K
S
HSSHSS
KS
HSS
C R
K
KS
H S
S
MD
HSS
MD
K S
K S
K S
K S
C R
K
KS
K S
H S
S H
S S
HSS
K S
CRKKP
K P
ID
S IDS
KP
K P
K P
KP
KP
K P
IDS IDS
ID
S
IDSK
P
K P
IDS
ID
S
ID
S
K P
ID
S
M D
MD MD
MD
C R
K
ID
S
CAM
S
M D
M D
M D
M D
MON
S
C R
K
HSS
H S
S H
S S
H S
S
C A
M S C
A M
S
CAM
S
C A
M S
C A
M S
K S
M O
N S
C R
K K
S
MON
S
M O
N S
M O
N S
M O
N S
M O
N S
MON
S
A C
S
CAM
CCTV,360
CAM
CCTV
CAM
CCTV
S
S
S S
S
S
S
S
WN
MD
S S S
S
ID
S
CAM
S
K P
S S
S
WN
S
WN
S
WN
S
WN
S
WN
S
WN
S
WN
S
WN
S
WN
S
WN
S
WN
S
WN
S
WN
S
WN
S
WN
S
WN
S
WN
M O
N S
C A
M S
K S
M O
N S
M O
N S
M O
N S
MON
S
HSS
S
S
CAM
S
M O
N S
GRAPHIC SECURITY LEGEND
ROOM NUMBER DESIGNATION
SECURE USE (HIGH) STC 50
(MINIMUM) (DESIGNED TO
ICD/ICS 705)
S STC 53 RATED DOOR
SECURE USE (MEDIUM) STC 50
(MINIMUM) (COLLATERAL USE
DESIGNED TO ICD/ICS 705)
SW STC 37 RATED WINDOWS
101A
SECURE USE (LOW) NON-STC
(COLLATERAL USE DESIGNED
TO DoD 5200.01 VOL 3)
CAM
CAM
CCTV
KS
CRK
ACS
MD
HSS
KP
IDS
WALL MOUNTED CAMERA - INTERIOR POINT TO
POINT SECURITY MONITORING SYSTEM
CCTV WALL MOUNTED CAMERA - EXTERIOREXT
CCTV SYSTEM - EQUIPMENT
KILL SWITCH - INTERIOR
CARD READER KEYPAD - INTERIOR
ACS PANEL
CEILING MOUNTED MOTION DETECTOR
WALL MOUNTED MOTION DETECTOR
HIGH SECURITY SWITCH
WALL MOUNTED KEY PAD
IDS CONTROL PANEL
SECURITY MONITORING SYSTEM POINT TO
POINT VIDEO DISPLAY - WALL MOUNTED
MON
NON-SECURE CONTROLLED
ACCESS USE (NON STC)
A
B
C
D
CAM CCTV CEILING MOUNTED CAMERA - INTERIOR
IDS ZONE
IDS ZONE
CCTV
S
MD
S
S ABOVE CEILING WHITE NOISE SPEAKER
BL ROTATING BEACON TYPE BLUE LIGHT
WHITE NOISE SURFACE MOUNTED SPEAKER
(MOUNT ON SECURE SIDE OF DOOR)
S
S
CCTV SECURITY MONITORMON
CCTV
S CEILING MOUNTED WHITE NOISE SPEAKER
WN
WHITE NOISE SURFACE MOUNTED TRANSDUCER
(MOUNT ON SECURE SIDE OF WINDOW)
S W
WHITE NOISE GENERATORWN
SOUND MASKING GENERATORWN
S
A B C
C.2
D
D.4
E F
2.7
5.3
2.2
3.3
3.7
3.8
4.1
4.4
6.5
7.4
130B
144C
145 146 147
MECHANICAL
YARD
144B
S
S
S
S
S
S
SS
SS
S
S
S
S
S
S
S
S
144A
S
S S
S
#1-5
#1-18 #1-17
#1-20
#1-16
#1-15
#1-12
#1-6
#1-11
#1-7
#1-10
#1-7
#1-12
#1-14
130A
S
A
A A
A
A
A
A A
A
A
AA
A
A A
A
A
C
D D
A
B
#1-12
#1-15
#1-7
#1-14
#1-16
#1-16 #1-16
#1-16
#1-17
#1-11
#1-6
#1-5
A #1-5
#1-5 #1-5
#1-5
#1-5
#1-10
#1-18
G-107/G-109
G-108/G-110
KEYPLAN - WEST - 1st FLOOR
GENERAL NOTES
1. REFER TO "TY" DRAWINGS FOR SPECIFIC REQUIREMENTS
FOR SECURITY SYSTEMS, ACCESS CONTROL SYSTEM,
CCTV SYSTEM AND SOUND MASKING SYSTEM.
A
SHEET
IDENTIFICATION
US Army Corps of
Engineers ®
Mobile District
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D E
S
IG
N E
D B
Y
B U
L L
O C
K T
IC
E
A S
S O
C
IA
T E
S
E
C
E R
V A
N T
E S
S T
R E
E T
P E
N S
A C
O L
A F
L O
R
ID
A
2 3 4 5
B
C
D
D R
A W
N B
Y
S B
M T
B Y
P L
O T
S C
A L
E
S
IZ
E
C K
D B
Y
P L
O T
D A
T E
D A
T E
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
P R
O J E
C T
N U
M B
E R
F
IL
E N
A M
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
:1 x
M O
B
IL
E D
IS
T
R
IC
T
M O
B
IL
E A
L A
B A
M A
M E
F
M
A Y
W
R
AMENDMENT 0001
/2
/2
:5
:0
P
M
C Y
B E
R S
P A
C E
T E
S T
G R
O U
P F
A C
IL
IT
Y
E G
L
IN
A F
B
F L
O R
ID
A
G-107
F
IR
S T
F L
O O
R S
E C
U R
IT
Y
P L
A N
W
E S
T
B
M A
G G
IO
R
E
T
W A
L L
IS
B
M
A G
G
IO
R E
B T
A
M
A Y
M E
F
G
FTFA 16-3007
FIRST FLOOR
ROOM
NUMBER ROOM NAME Area
100 LOBBY 300 SF
101 BREAKROOM 407 SF
102 CORR. 1409 SF
103 ELEV. 58 SF
104 JANITOR 70 SF
105 ELEC. 474 SF
106 MEN 221 SF
106A SHOWER 76 SF
107 WOMENS 221 SF
107A SHOWER 76 SF
108 ELEVATOR EQUIPMENT 127 SF
109 SERVICE ELEVATOR 88 SF
110 LOGISTICS/CE REP 844 SF
110A RECYCLE ROOM 79 SF
111 COMSEC 146 SF
112 VESTIBULE 111 SF
113 STAIR 2 239 SF
114 NCR SERVER ROOM 1108 SF
115 SECURE STORAGE 167 SF
116 SECURE CORRIDOR 123 SF
117 CORR. 321 SF
118 TEST SUITE 269 SF
119 NCR SECURITY MGRS 198 SF
120 RANGE OPS CENTER 337 SF
121 TEST SUITE 208 SF
122 TEST SUITE 213 SF
123 TEST SUITE 423 SF
124 TEST SUITE 426 SF
125 TEST SUITE 238 SF
126 TEST SUITE 239 SF
127 NCR CONFERENCE ROOM 690 SF
128 ACR GSSO 186 SF
129 ACR STORAGE 202 SF
130A CORR. 65 SF
130B ACR ISSO 932 SF
132 ACR ISSM 177 SF
133 ACR SYSADM 433 SF
134 CORRIDOR 623 SF
135 ACR CONF. RM 689 SF
136 AVIONICS TEST LAB 2534 SF
137 ATL STORAGE 175 SF
138 ATL ANALYSIS 347 SF
139 CYBER/EW LAB 2364 SF
140 C/EW ANALYSIS 276 SF
141 COMM RM 94 SF
142 CORR. 246 SF
143 STAIR 1 254 SF
144A POWER VESTIBULE MANTRAP 194 SF
144B DEV & RE LAB 466 SF
144C THREAT DEVELOPMENT LAB 764 SF
145 REPORT WRITING 1 192 SF
146 REPORT WRITING 2 192 SF
147 THREAT RESEARCH ROOM 215 SF
148 ACR SERVER 392 SF
149 COLLATERAL SECURITY 231 SF
150 COLLATERAL SECURITY LEAD 116 SF
151 BADGE 275 SF
152 COMM RM 304 SF
153 MECH. 555 SF
154 FIRE PUMP 130 SF
SCALE: 1/8" = 1'-0"
0 4' 8' 16'
1/8" = 1'-0"G-107
1 FIRST FLOOR SECURITY PLAN - WEST
PLAN
NORTH
A
M E
N D
M E
N T
/2
/2
BLBL
BL
BL BL
BL
BL
BL
BL
BL
BL
BL
BL
BL
BL
BL
BL
BL
HSS
HSS
CRK
C R
K
C R
K
C R
K
C R
K
C R
K
CRK
CRK
CRK
C R
K
C R
K
CRK
CRK
CRK
CRK
IDS
MD
MD
CAM
S
HSSHSS
C R
KA
C
S
K P
CAM
CCTV,EXT
K S
M O
N S
MON
S
MON MON
S
C A
M S
MH
HSS
CRK
MON
S
M O
N S
KS
KS
K S
K S
K S
K S
K S
K S
CRK
MD
H S
S
K S
KS
C R
K
HSS HSS
MD
MD
C R
K
M O
N S
K P
IDS
IDS
IDS
KP
K P
K P
ID
S
C R
K
CAM
S
CRK
MD
C A
M S
CAM
S
C R
K
WN
C A
M S
KP
C R
K CAM
S
H S
S
MD
MON
S
M O
N S
ACS
CAM
CCTV,360
CAM
CCTV
CAM
CCTV
CAM
CCTV
S
S
WN
MON
CCTV
CRK
C R
K C
R K
S
S
S
S
S S
S S
S S
S
MON
S
KPMD
H S
S M
O N
S
S
S
C R
K
S S
S
CRK
HSSKP
MD
S
WN
S
WN
S
WN
S
WN
S
WN
S
WN
S
WN
S
WN
S
WN
S
WN
S
WN
S
WN
S
WN
S
WN
ID
S
CAM
S
CAM
S
S
WN
S
WN
S
WN
MON
CCTV
GRAPHIC SECURITY LEGEND
ROOM NUMBER DESIGNATION
SECURE USE (HIGH) STC 50
(MINIMUM) (DESIGNED TO
ICD/ICS 705)
S STC 53 RATED DOOR
SECURE USE (MEDIUM) STC 50
(MINIMUM) (COLLATERAL USE
DESIGNED TO ICD/ICS 705)
SW STC 37 RATED WINDOWS
101A
SECURE USE (LOW) NON-STC
(COLLATERAL USE DESIGNED
TO DoD 5200.01 VOL 3)
CAM
CAM
CCTV
KS
CRK
ACS
MD
HSS
KP
IDS
WALL MOUNTED CAMERA - INTERIOR POINT TO
POINT SECURITY MONITORING SYSTEM
CCTV WALL MOUNTED CAMERA - EXTERIOREXT
CCTV SYSTEM - EQUIPMENT
KILL SWITCH - INTERIOR
CARD READER KEYPAD - INTERIOR
ACS PANEL
CEILING MOUNTED MOTION DETECTOR
WALL MOUNTED MOTION DETECTOR
HIGH SECURITY SWITCH
WALL MOUNTED KEY PAD
IDS CONTROL PANEL
SECURITY MONITORING SYSTEM POINT TO
POINT VIDEO DISPLAY - WALL MOUNTED
MON
NON-SECURE CONTROLLED
ACCESS USE (NON STC)
A
B
C
D
CAM CCTV CEILING MOUNTED CAMERA - INTERIOR
IDS ZONE
IDS ZONE
CCTV
S
MD
S
S ABOVE CEILING WHITE NOISE SPEAKER
BL ROTATING BEACON TYPE BLUE LIGHT
WHITE NOISE SURFACE MOUNTED SPEAKER
(MOUNT ON SECURE SIDE OF DOOR)
S
S
CCTV SECURITY MONITORMON
CCTV
S CEILING MOUNTED WHITE NOISE SPEAKER
WN
WHITE NOISE SURFACE MOUNTED TRANSDUCER
(MOUNT ON SECURE SIDE OF WINDOW)
S W
WHITE NOISE GENERATORWN
SOUND MASKING GENERATORWN
S
F G H J K M N P
2.7
5.3
M.2
2.2
3.3
3.7
3.8
4.1
4.4
6.5
7.4
103 104
106 107
121122
125 116
108 110A
GENERATOR YARD
S
S
S
SS
SS
S
S
S
106A 107A
S
S
S
S
S
S
#1-3A
#1-2
#1-1
#1-19
#1-4 #1-3.2
#1-3.1
S
D
A
A A A A
A
A
A A
A
A
A A
C C
D D D
D D
B
D
PUBLIC AREA
D
B
#1-3A
#1-3A
#1-3A
#1-3
#1-3A#1-3A#1-3A
#1-3A
#1-3A
#1-1
#1-4
#1-19
#1-2
#1-3.2
#1-3.1
G-107/G-109
G-108/G-110
KEYPLAN - EAST - 1st FLOOR
GENERAL NOTES
1. REFER TO "TY" DRAWINGS FOR SPECIFIC REQUIREMENTS
FOR SECURITY SYSTEMS, ACCESS CONTROL SYSTEM,
CCTV SYSTEM AND SOUND MASKING SYSTEM.
A
SHEET
IDENTIFICATION
US Army Corps of
Engineers ®
Mobile District
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D E
S
IG
N E
D B
Y
B U
L L
O C
K T
IC
E
A S
S O
C
IA
T E
S
E
C
E R
V A
N T
E S
S T
R E
E T
P E
N S
A C
O L
A F
L O
R
ID
A
2 3 4 5
B
C
D
D R
A W
N B
Y
S B
M T
B Y
P L
O T
S C
A L
E
S
IZ
E
C K
D B
Y
P L
O T
D A
T E
D A
T E
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
P R
O J E
C T
N U
M B
E R
F
IL
E N
A M
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
:1 x
M O
B
IL
E D
IS
T
R
IC
T
M O
B
IL
E A
L A
B A
M A
M E
F
M
A Y
W
R
AMENDMENT 0001
/2
/2
:5
:3
P
M
C Y
B E
R S
P A
C E
T E
S T
G R
O U
P F
A C
IL
IT
Y
E G
L
IN
A F
B
F L
O R
ID
A
G-108
F
IR
S T
F L
O O
R S
E C
U R
IT
Y
P L
A N
E
A S
T
B
M A
G G
IO
R
E
T
W A
L L
IS
B
M
A G
G
IO
R E
B T
A
M
A Y
M E
F
G
FTFA 16-3007
FIRST FLOOR
ROOM
NUMBER ROOM NAME Area
100 LOBBY 300 SF
101 BREAKROOM 407 SF
102 CORR. 1409 SF
103 ELEV. 58 SF
104 JANITOR 70 SF
105 ELEC. 474 SF
106 MEN 221 SF
106A SHOWER 76 SF
107 WOMENS 221 SF
107A SHOWER 76 SF
108 ELEVATOR EQUIPMENT 127 SF
109 SERVICE ELEVATOR 88 SF
110 LOGISTICS/CE REP 844 SF
110A RECYCLE ROOM 79 SF
111 COMSEC 146 SF
112 VESTIBULE 111 SF
113 STAIR 2 239 SF
114 NCR SERVER ROOM 1108 SF
115 SECURE STORAGE 167 SF
116 SECURE CORRIDOR 123 SF
117 CORR. 321 SF
118 TEST SUITE 269 SF
119 NCR SECURITY MGRS 198 SF
120 RANGE OPS CENTER 337 SF
121 TEST SUITE 208 SF
122 TEST SUITE 213 SF
123 TEST SUITE 423 SF
124 TEST SUITE 426 SF
125 TEST SUITE 238 SF
126 TEST SUITE 239 SF
127 NCR CONFERENCE ROOM 690 SF
128 ACR GSSO 186 SF
129 ACR STORAGE 202 SF
130A CORR. 65 SF
130B ACR ISSO 932 SF
132 ACR ISSM 177 SF
133 ACR SYSADM 433 SF
134 CORRIDOR 623 SF
135 ACR CONF. RM 689 SF
136 AVIONICS TEST LAB 2534 SF
137 ATL STORAGE 175 SF
138 ATL ANALYSIS 347 SF
139 CYBER/EW LAB 2364 SF
140 C/EW ANALYSIS 276 SF
141 COMM RM 94 SF
142 CORR. 246 SF
143 STAIR 1 254 SF
144A POWER VESTIBULE MANTRAP 194 SF
144B DEV & RE LAB 466 SF
144C THREAT DEVELOPMENT LAB 764 SF
145 REPORT WRITING 1 192 SF
146 REPORT WRITING 2 192 SF
147 THREAT RESEARCH ROOM 215 SF
148 ACR SERVER 392 SF
149 COLLATERAL SECURITY 231 SF
150 COLLATERAL SECURITY LEAD 116 SF
151 BADGE 275 SF
152 COMM RM 304 SF
153 MECH. 555 SF
154 FIRE PUMP 130 SF
1/8" = 1'-0"G-108
1 FIRST FLOOR SECURITY PLAN - EAST
PLAN
NORTH
SCALE: 1/8" = 1'-0"
0 4' 8' 16'
A
M E
N D
M E
N T
/2
/2
BL BL
BLBL
BLBL
BL
BLBL
BLBL
BL
BL
BL
BL
BL BL
BL BL
BL
BL
BL BL
BL
BL
BL
C R
K
C R
K
CRK
CRK
CRK
C R
K
C R
K
C R
K
C R
K
C R
K
C R
K
H S
S
H S
S
H S
S
HSS HSS
M D
MD
MD
MD MD
HSS
MD
C R
K
KP
K P
KP
ID
S
ID
S
ID
S
ID
S
KP
C R
K
MD
H S
S
C A
M S
ID
S
CAM
S
S S
C A
M S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
S S
C R
K
MON
S
MON
S
CAM
CCTV,360
CAM
CCTV
CAM
CCTV
CAM
CCTV,180,EXT
CAM CCTV,E
XT
CAM
CCTV,EXT
S
W S
W S
W S
W S
W S
W
S W
S W
S W
S W
S W
S W
S W
S W
S W
S W
S W
S W
S
S
S
S
S
S
M O
N S
S
C A
M C
C T
V
GRAPHIC SECURITY LEGEND
ROOM NUMBER DESIGNATION
SECURE USE (HIGH) STC 50
(MINIMUM) (DESIGNED TO
ICD/ICS 705)
S STC 53 RATED DOOR
SECURE USE (MEDIUM) STC 50
(MINIMUM) (COLLATERAL USE
DESIGNED TO ICD/ICS 705)
SW STC 37 RATED WINDOWS
101A
SECURE USE (LOW) NON-STC
(COLLATERAL USE DESIGNED
TO DoD 5200.01 VOL 3)
CAM
CAM
CCTV
KS
CRK
ACS
MD
HSS
KP
IDS
WALL MOUNTED CAMERA - INTERIOR POINT TO
POINT SECURITY MONITORING SYSTEM
CCTV WALL MOUNTED CAMERA - EXTERIOREXT
CCTV SYSTEM - EQUIPMENT
KILL SWITCH - INTERIOR
CARD READER KEYPAD - INTERIOR
ACS PANEL
CEILING MOUNTED MOTION DETECTOR
WALL MOUNTED MOTION DETECTOR
HIGH SECURITY SWITCH
WALL MOUNTED KEY PAD
IDS CONTROL PANEL
SECURITY MONITORING SYSTEM POINT TO
POINT VIDEO DISPLAY - WALL MOUNTED
MON
NON-SECURE CONTROLLED
ACCESS USE (NON STC)
A
B
C
D
CAM CCTV CEILING MOUNTED CAMERA - INTERIOR
IDS ZONE
IDS ZONE
CCTV
S
MD
S
S ABOVE CEILING WHITE NOISE SPEAKER
BL ROTATING BEACON TYPE BLUE LIGHT
WHITE NOISE SURFACE MOUNTED SPEAKER
(MOUNT ON SECURE SIDE OF DOOR)
S
S
CCTV SECURITY MONITORMON
CCTV
S CEILING MOUNTED WHITE NOISE SPEAKER
WN
WHITE NOISE SURFACE MOUNTED TRANSDUCER
(MOUNT ON SECURE SIDE OF WINDOW)
S W
WHITE NOISE GENERATORWN
SOUND MASKING GENERATORWN
S
A B C
C.2
D
D.4
E F
2.7
5.3
2.2
3.3
3.7
3.8
4.1
4.4
6.5
7.4
234 239
231 230 229 228
227 226
224A
SW
SW
S
S
S
S
S S
S
#2-11
#2-10
#2-13
SW
SW
SW
SW
SW
SW SW SW SW SW SW SW SW SW SW
#2-12
S
B
B
B
B
C
C C
#2-11
#2-12
#2-13
#2-10
G-107/G-109
G-108/G-110
KEYPLAN - WEST - 2nd FLOOR
GENERAL NOTES
1. REFER TO "TY" DRAWINGS FOR SPECIFIC REQUIREMENTS
FOR SECURITY SYSTEMS, ACCESS CONTROL SYSTEM,
CCTV SYSTEM AND SOUND MASKING SYSTEM.
A
SHEET
IDENTIFICATION
US Army Corps of
Engineers ®
Mobile District
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D E
S
IG
N E
D B
Y
B U
L L
O C
K T
IC
E
A S
S O
C
IA
T E
S
E
C
E R
V A
N T
E S
S T
R E
E T
P E
N S
A C
O L
A F
L O
R
ID
A
2 3 4 5
B
C
D
D R
A W
N B
Y
S B
M T
B Y
P L
O T
S C
A L
E
S
IZ
E
C K
D B
Y
P L
O T
D A
T E
D A
T E
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
P R
O J E
C T
N U
M B
E R
F
IL
E N
A M
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
:1 x
M O
B
IL
E D
IS
T
R
IC
T
M O
B
IL
E A
L A
B A
M A
M E
F
M
A Y
W
R
AMENDMENT 0001
/2
/2
:5
:0
P
M
C Y
B E
R S
P A
C E
T E
S T
G R
O U
P F
A C
IL
IT
Y
E G
L
IN
A F
B
F L
O R
ID
A
G-109
S E
C O
N D
F L
O O
R S
E C
U R
IT
Y
P L
A N
W
E S
T
B
M A
G G
IO
R
E
T
W A
L L
IS
B
M
A G
G
IO
R E
B T
A
M
A Y
M E
F
G
FTFA 16-3007
SECOND FLOOR
ROOM
NUMBER ROOM NAME Area
200 CORR. 1587 SF
201 VESTIBULE 126 SF
202 IDE SERVER RM 475 SF
203 EVENT DESIGN COLLABORATION 299 SF
204 EVENT DESIGN COLLABORATION 321 SF
205 ELEV. 58 SF
206 ELECTRICAL 202 SF
207 BREAKROOM 358 SF
208 47 CTS CONFERENCE 633 SF
209 SERVICE ELEVATOR 88 SF
210 ITS WORKSTATIONS/WORK
BENCH/TRAINING
551 SF
211 ITS STORAGE 221 SF
212 ITS MISSION PREP 162 SF
213 STAIRS 354 SF
214 96 CTG. SEC. COMM. 297 SF
215 WORK AREA 1974 SF
216 OFFICE 124 SF
217 OFFICE 124 SF
218 TEST TOOL/EQUIP. STAGING 183 SF
219 MEN 286 SF
220 WOMEN 220 SF
220A LACTATION RM 67 SF
221 GROUP CLASSROOM 920 SF
221A STORAGE 226 SF
222 INVESTMENT GROUP 858 SF
223 INVESTMENT LEAD 118 SF
224 WORK AREA 3037 SF
224A OFFICE 165 SF
225 WORK AREA 4416 SF
226 OFFICE 164 SF
227 OFFICE 167 SF
228 OFFICE 122 SF
229 OFFICE 122 SF
230 OFFICE 122 SF
231 OFFICE 180 SF
232 CORR. 228 SF
233 STAIRS 260 SF
234 COMM RM 110 SF
235 IDE OFFICE 116 SF
236 IDE OFFICE 116 SF
237 IDE OFFICE 116 SF
238 IDE OFFICE 183 SF
239 MECH. 350 SF
240 COMM RM 239 SF
241 JANITOR 51 SF
242 STOR. 60 SF
243 EVENT DESIGN CENTER 1986 SF
SCALE: 1/8" = 1'-0"
0 4' 8' 16'
1/8" = 1'-0"G-109
1 SECOND FLOOR SECURITY PLAN - WEST
PLAN
NORTH
A
M E
N D
M E
N T
/2
/2
BLBL
BL
BLBL
BL
BL
BL
BL
BL
BL
BL
BLBLBL
BL
BL
BL
BL
BL
BL
BL
BL
BL
ID
S
C R
K
C R
K
C R
K
C R
K
C R
K
HSS
HSS
MD
MD
CAM
S
C R
K
C R
K
C R
K
C R
K
C R
K
C R
K
CRK
CRK
C R
K
C R
K
CCTV
ID
S
IDS
ID
S
K S
K S
MD
MD
ID
S
CAM
S
M O
N S
M O
N S
M O
N S
S S
S S
HSS
CRK
C R
K
HSS
MD
C R
K
HSS
CRK
CRK
HSS
K P
K P K P
IDS
ID
S
K P
KP
K P
K P
K P
C R
K
CRK
M D
CAM
S
CAM
S
MON
S
MD
ID
S
M O
N S
MON
S
CAM
S
CAM
S
S S
S S
S S
WN
S
M O
N S
MON
S
M O
N S
HSS
M D
CAM
S
CAM
CCTV
CAM
CCTV
CAM
CCTV
CAM
CCTV
CAM
CCTV,180,EXT
CAM
CCTV,180,EXT
CAM
CCTV,E
XT
CAM
CCTV,EXT
S W
S W
S W
S W
S W
S W
S W
S W
S W
S S
S
S
S
S
S
S
HSS
S
S
GRAPHIC SECURITY LEGEND
ROOM NUMBER DESIGNATION
SECURE USE (HIGH) STC 50
(MINIMUM) (DESIGNED TO
ICD/ICS 705)
S STC 53 RATED DOOR
SECURE USE (MEDIUM) STC 50
(MINIMUM) (COLLATERAL USE
DESIGNED TO ICD/ICS 705)
SW STC 37 RATED WINDOWS
101A
SECURE USE (LOW) NON-STC
(COLLATERAL USE DESIGNED
TO DoD 5200.01 VOL 3)
CAM
CAM
CCTV
KS
CRK
ACS
MD
HSS
KP
IDS
WALL MOUNTED CAMERA - INTERIOR POINT TO
POINT SECURITY MONITORING SYSTEM
CCTV WALL MOUNTED CAMERA - EXTERIOREXT
CCTV SYSTEM - EQUIPMENT
KILL SWITCH - INTERIOR
CARD READER KEYPAD - INTERIOR
ACS PANEL
CEILING MOUNTED MOTION DETECTOR
WALL MOUNTED MOTION DETECTOR
HIGH SECURITY SWITCH
WALL MOUNTED KEY PAD
IDS CONTROL PANEL
SECURITY MONITORING SYSTEM POINT TO
POINT VIDEO DISPLAY - WALL MOUNTED
MON
NON-SECURE CONTROLLED
ACCESS USE (NON STC)
A
B
C
D
CAM CCTV CEILING MOUNTED CAMERA - INTERIOR
IDS ZONE
IDS ZONE
CCTV
S
MD
S
S ABOVE CEILING WHITE NOISE SPEAKER
BL ROTATING BEACON TYPE BLUE LIGHT
WHITE NOISE SURFACE MOUNTED SPEAKER
(MOUNT ON SECURE SIDE OF DOOR)
S
S
CCTV SECURITY MONITORMON
CCTV
S CEILING MOUNTED WHITE NOISE SPEAKER
WN
WHITE NOISE SURFACE MOUNTED TRANSDUCER
(MOUNT ON SECURE SIDE OF WINDOW)
S W
WHITE NOISE GENERATORWN
SOUND MASKING GENERATORWN
S
F G H J K M N P
2.7
5.3
M.2
2.2
3.3
3.7
3.8
4.1
4.4
6.5
7.4
208204
220 219
237236235
241 242
SW
S
S
SS
S
S
S S
221A
S
S
#2-9
#2-8
#2-14
#2-1
#2-4
#2-7 #2-6
#2-5
S
220A
SW SW SW SW SW
SW
SW
SW
S
B
C
B B B B
B
BBBB
C
C
D
B
C
#2-9 #2-8
#2-14
#2-13
#2-1
#2-1 #2-1 #2-4
#2-5
#2-6 #2-7
G-107/G-109
G-108/G-110
KEYPLAN - EAST - 2nd FLOOR
GENERAL NOTES
1. REFER TO "TY" DRAWINGS FOR SPECIFIC REQUIREMENTS
FOR SECURITY SYSTEMS, ACCESS CONTROL SYSTEM,
CCTV SYSTEM AND SOUND MASKING SYSTEM.
A
SHEET
IDENTIFICATION
US Army Corps of
Engineers ®
Mobile District
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D E
S
IG
N E
D B
Y
B U
L L
O C
K T
IC
E
A S
S O
C
IA
T E
S
E
C
E R
V A
N T
E S
S T
R E
E T
P E
N S
A C
O L
A F
L O
R
ID
A
2 3 4 5
B
C
D
D R
A W
N B
Y
S B
M T
B Y
P L
O T
S C
A L
E
S
IZ
E
C K
D B
Y
P L
O T
D A
T E
D A
T E
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
P R
O J E
C T
N U
M B
E R
F
IL
E N
A M
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
:1 x
M O
B
IL
E D
IS
T
R
IC
T
M O
B
IL
E A
L A
B A
M A
M E
F
M
A Y
W
R
AMENDMENT 0001
/2
/2
:5
:1
P
M
C Y
B E
R S
P A
C E
T E
S T
G R
O U
P F
A C
IL
IT
Y
E G
L
IN
A F
B
F L
O R
ID
A
G-110
S E
C O
N D
F L
O O
R S
E C
U R
IT
Y
P L
A N
E
A S
T
B
M A
G G
IO
R
E
T
W A
L L
IS
B
M
A G
G
IO
R E
B T
A
M
A Y
M E
F
G
FTFA 16-3007
SECOND FLOOR
ROOM
NUMBER ROOM NAME Area
200 CORR. 1587 SF
201 VESTIBULE 126 SF
202 IDE SERVER RM 475 SF
203 EVENT DESIGN COLLABORATION 299 SF
204 EVENT DESIGN COLLABORATION 321 SF
205 ELEV. 58 SF
206 ELECTRICAL 202 SF
207 BREAKROOM 358 SF
208 47 CTS CONFERENCE 633 SF
209 SERVICE ELEVATOR 88 SF
210 ITS WORKSTATIONS/WORK
BENCH/TRAINING
551 SF
211 ITS STORAGE 221 SF
212 ITS MISSION PREP 162 SF
213 STAIRS 354 SF
214 96 CTG. SEC. COMM. 297 SF
215 WORK AREA 1974 SF
216 OFFICE 124 SF
217 OFFICE 124 SF
218 TEST TOOL/EQUIP. STAGING 183 SF
219 MEN 286 SF
220 WOMEN 220 SF
220A LACTATION RM 67 SF
221 GROUP CLASSROOM 920 SF
221A STORAGE 226 SF
222 INVESTMENT GROUP 858 SF
223 INVESTMENT LEAD 118 SF
224 WORK AREA 3037 SF
224A OFFICE 165 SF
225 WORK AREA 4416 SF
226 OFFICE 164 SF
227 OFFICE 167 SF
228 OFFICE 122 SF
229 OFFICE 122 SF
230 OFFICE 122 SF
231 OFFICE 180 SF
232 CORR. 228 SF
233 STAIRS 260 SF
234 COMM RM 110 SF
235 IDE OFFICE 116 SF
236 IDE OFFICE 116 SF
237 IDE OFFICE 116 SF
238 IDE OFFICE 183 SF
239 MECH. 350 SF
240 COMM RM 239 SF
241 JANITOR 51 SF
242 STOR. 60 SF
243 EVENT DESIGN CENTER 1986 SF
1/8" = 1'-0"G-110
1 SECOND FLOOR SECURITY PLAN - EAST
PLAN
NORTH
SCALE: 1/8" = 1'-0"
0 4' 8' 16'
A
M E
N D
M E
N T
/2
/2
GENERAL NOTES
1. DRAWINGS ON THIS SHEET ARE
PROVIDED TO SHOW DIAGRAMMATIC
LOCATION OF AIR BARRIER.
2. SEE SHEET A-002 THRU A-005 FOR
SPECIFIC WALL CONSTRUCTION
INFORMATION.
3. SEE WALL SECTIONS AND DETAILS
FOR ADDITIONAL AIR BARRIER
INFORMATION.
GRAPHIC LEGEND
AIR BARRIER LOCATION
KEYNOTES
PAINTED GYPSUM WALLBOARD
PERFORMS AS AIR BARRIER.
CONCRETE SLAB PERFORMS AS AIR
BARRIER.
ROOFING UNDERLAYMENT PERFORMS
AS AIR BARRIER
FLUID APPLIED AIR/MOISTURE
BARRIER PERFORMS AS AIR BARRIER.
A
B
C
D
SURFACE AREA
TEST ZONE 1:
TEST ZONE 2:
TEST ZONE 3:
TEST ZONE 4:
125,326 SF
2,873 SF
1,442 SF
1,002 SF
MEN
WORK AREA
OFFICE
CORR.
BREAKROOM
47 CTS
CONFERENCE
ELEC.
CORR.
SECURE
CORRIDOR
CORR.
TEST SUITE
C C
D
B B
D
D
D
WORK AREA
CORR.
MECH.
EVENT DESIGN
CENTER
IDE OFFICE
ACR ISSO
130B
ACR STORAGE
CORRIDOR
ACR SERVER
MECH.
C
D
B B B
B
DA
C
D
A
SHEET
IDENTIFICATION
US Army Corps of
Engineers ®
Mobile District
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D E
S
IG
N E
D B
Y
B U
L L
O C
K T
IC
E
A S
S O
C
IA
T E
S
E
C
E R
V A
N T
E S
S T
R E
E T
P E
N S
A C
O L
A F
L O
R
ID
A
2 3 4 5
B
C
D
D R
A W
N B
Y
S B
M T
B Y
P L
O T
S C
A L
E
S
IZ
E
C K
D B
Y
P L
O T
D A
T E
D A
T E
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
P R
O J E
C T
N U
M B
E R
F
IL
E N
A M
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
:1 x
M O
B
IL
E D
IS
T
R
IC
T
M O
B
IL
E A
L A
B A
M A
M E
F
M
A Y
W
R
AMENDMENT 0001
/2
/2
:5
:0
P
M
C Y
B E
R S
P A
C E
T E
S T
G R
O U
P F
A C
IL
IT
Y
E G
L
IN
A F
B
F L
O R
ID
A
G-113
A
IR
B A
R R
IE
R
B U
IL
D
IN
G
S E
C T
IO
N
S
B
M A
G G
IO
R
E
R .F
IV
E
A S
H B
M
A G
G
IO
R E
B T
A
M
A Y
M E
F
G
FTFA 16-3007
1/8" = 1'-0"G-113
1 SECTION - AIR BARRIER DIAGRAM
1/8" = 1'-0"G-113
2 SECTION - AIR BARRIER DIAGRAM
MECHANICL
YARD
SCALE: 1/8" = 1'-0"
0 4' 8' 16'
A
M E
N D
M E
N T
/2
/2
INVESTMENT
GROUP
CORR.
COMM RM
IDE OFFICE
COMM RM
NCR
CONFERENCE
ROOM
CORR.
COLLATERAL
SECURITY
C C
D
D
A
B
A
B
D
D
B
ACR CONF. RM
CORRIDOR
REPORT WRITING
POWER
VESTIBULE
MANTRAP
144A
DEV & RE LAB
144B
EVENT DESIGN
CENTER
CORR.
WORK AREA
OFFICE
224A
GRAPHIC LEGEND
AIR BARRIER LOCATION
GENERAL NOTES
1. DRAWINGS ON THIS SHEET ARE
PROVIDED TO SHOW DIAGRAMMATIC
LOCATION OF AIR BARRIER.
2. SEE SHEET A-002 THRU A-005 FOR
SPECIFIC WALL CONSTRUCTION
INFORMATION.
3. SEE WALL SECTIONS AND DETAILS
FOR ADDITIONAL AIR BARRIER
INFORMATION.
SURFACE AREA
TEST ZONE 1:
TEST ZONE 2:
TEST ZONE 3:
TEST ZONE 4:
125,326 SF
2,873 SF
1,442 SF
1,002 SF
KEYNOTES
PAINTED GYPSUM WALLBOARD
PERFORMS AS AIR BARRIER.
CONCRETE SLAB PERFORMS AS AIR
BARRIER.
ROOFING UNDERLAYMENT PERFORMS
AS AIR BARRIER
FLUID APPLIED AIR/MOISTURE
BARRIER PERFORMS AS AIR BARRIER.
A
B
C
D
A
SHEET
IDENTIFICATION
US Army Corps of
Engineers ®
Mobile District
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D E
S
IG
N E
D B
Y
B U
L L
O C
K T
IC
E
A S
S O
C
IA
T E
S
E
C
E R
V A
N T
E S
S T
R E
E T
P E
N S
A C
O L
A F
L O
R
ID
A
2 3 4 5
B
C
D
D R
A W
N B
Y
S B
M T
B Y
P L
O T
S C
A L
E
S
IZ
E
C K
D B
Y
P L
O T
D A
T E
D A
T E
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
P R
O J E
C T
N U
M B
E R
F
IL
E N
A M
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
:1 x
M O
B
IL
E D
IS
T
R
IC
T
M O
B
IL
E A
L A
B A
M A
M E
F
M
A Y
W
R
AMENDMENT 0001
/2
/2
:5
:2
P
M
C Y
B E
R S
P A
C E
T E
S T
G R
O U
P F
A C
IL
IT
Y
E G
L
IN
A F
B
F L
O R
ID
A
G-114
A
IR
B A
R R
IE
R
B U
IL
D
IN
G
S E
C T
IO
N
S
B
M A
G G
IO
R
E
R .F
IV
E
A S
H B
M
A G
G
IO
R E
B T
A
M
A Y
M E
F
G
FTFA 16-3007
1/8" = 1'-0"G-114
1 SECTION - AIR BARRIER DIAGAM
1/8" = 1'-0"G-114
2 SECTION - AIR BARRIER DIAGRAM
C C
D
A
BB
D
D
D
C
SCALE: 1/8" = 1'-0"
0 4' 8' 16'
A
M E
N D
M E
N T
/2
/2
B
SHEET
IDENTIFICATION
US Army Corps of
Engineers ®
Mobile District
U S
A
R M
Y
C
O R
P S
O
F
E
N G
I N
E E
R S
D E
S I G
N E
D
B
Y
B U
L L
O C
K
T
I C
E
A
S S
O C
I A
T E
S
E
C
E R
V A
N T
E
T R
E E
T
S
U I T
E
B
P E
N S
A C
O L
A
F
L O
R I D
A
2 3 4 5
B
C
D
D R
A W
N
B
Y
S B
M
B
Y
P L
C A
L E
S I Z
E
C K
D
B
Y
P L
D
T
E
D A
T E
S O
L I C
I T
A T
I O
N
N
O
C O
N T
R A
N
P R
O J E
U M
B E
R
F I L
E
N
A M
E
M A
R K
D E
S C
R I P
T I O
N D
A T
E A
P P
R x
M O
B I L
E
D
I S
T R
I C
T
M O
B I L
E
A
L A
B A
M A
M E
F
C Y
B E
R S
P A
S
T
G
R O
C
I L
I T
Y
E G
L I
B
F
L O
R I D
A
V:
\2
6\ ac tiv e\
4\ ci vil
\d ra w in g\
_d sg n\ sh ee t_ file s\
M
EF
7C I0
.d w g
/0 7/
:3
PM B
y:
G er th , J am es
W R
CI001FTFA 163007
G E
N E
R A
L
C
I V
L
T
E S
C
B
R O
C K
M E
I E
R
J
G
E R
T H
S T
A N
T E
C
A
M
O R
A L E
S
M E
F C
I D
W G
M
M
GENERAL CIVIL NOTES
GENERAL:
1. BENCHMARK FOR CONSTRUCTION HAS BEEN PROVIDED ON SHEET V-102.
2. ALL LABOR, MATERIALS, AND METHODS OF CONSTRUCTION SHALL BE IN
STRICT ACCORDANCE WITH THE MINIMUM ENGINEERING AND
CONSTRUCTION STANDARDS ADOPTED BY THE U.S, ARMY CORPS OF
ENGINEERS (USACE) MOBILE DISTRICT. WHERE CONFLICTS OR OMISSIONS
EXIST, THE USACE (MOBILE DISTRICT) STANDARDS SHALL DICTATE.
SUBSTITUTIONS AND DEVIATION FROM PLANS AND SPECIFICATIONS SHALL
BE PERMITTED ONLY WHEN WRITTEN APPROVAL HAS BEEN ISSUED BY
THE CONTRACTING OFFICER'S REPRESENTATIVE (COR).
3. SHOP DRAWINGS OF ALL MATERIALS BEING USED SHALL BE SUBMITTED
AS PER SPECIFICATI0NS (SUBMITTALS).
4. ANY PENALTIES, STOP WORK ORDERS OR ADDITIONAL WORK RESULTING
FROM THE CONTRACTOR BEING IN VIOLATION OF THE REQUIREMENTS
ABOVE, SHALL BE FULLY BORNE BY THE CONTRACTOR.
5. PRIOR TO THE START OF ANY CONSTRUCTION ACTIVITY IT SHALL BE THE
CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE VARIOUS UTILITIES AND
TO MAKE THE NECESSARY ARRANGEMENTS FOR ANY RELOCATION OF
THESE UTILITIES WITH THE OWNER OF THE UTILITY. THE CONTRACTOR
SHALL EXERCISE CAUTION WHEN CROSSING UNDERGROUND UTILITIES,
WHETHER SHOWN ON THE PLAN OR LOCATED BY THE UTILITY COMPANY.
ALL UTILITIES WHICH INTERFERE WITH THE PROPOSED CONSTRUCTION
SHALL BE BROUGHT TO THE ATTENTION OF THE COR FIRST.
6. THE SEQUENCE OF CONSTRUCTION SHALL BE SUCH THAT ALL
UNDERGROUND INSTALLATIONS OF EVERY KIND, INCLUDING LANDSCAPE
SPRINKLERS LINES, SHALL BE PLACED BENEATH THE PAVEMENT AND ITS
EDGES PRIOR TO THE CONSTRUCTION OF THE PAVEMENT. THE
PAVEMENT SHALL NOT BE CUT WITHOUT PRIOR APPROVAL OF THE COR.
7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PREVENTING ANY
CONSTRUCTION ACTIVITIES FROM TAKING PLACE OUTSIDE OF THE LIMITS
OF CONSTRUCTION SHOWN ON THE PLANS. ANY ON-SITE OR OFFSITE
AREAS DISTURBED BY CONTRACTOR OR SUB CONTRACTOR (EQUIPMENT
AND/OR PERSONNEL VEHICLES) SHALL BE RESTORED TO ORIGINAL
CONDITION OR BETTER.
8. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE EXISTING SITE
CONDITIONS OF SOIL PRIOR TO NOTICE TO PROCEED. CONTRACTOR TO
DETERMINE IF ANY OFF SITE MATERIALS WILL NEED TO BE IMPORTED TO
ACHIEVE THE GRADES SPECIFIED ON THE PLANS.
9. CONTRACTOR TO PERFORM FIRE FLOW TEST ON ALL ADJACENT FIRE
HYDRANTS. FINAL FLOW TESTS AT THE END OF THE PROJECT WILL BE
REQUIRED ON ALL NEW FIRE HYDRANTS INSTALLED.
10. ALL PERMITTING AND REGULATORY COORDINATION MUST BE
CONDUCTED THROUGH THE EGLIN AFB CIVIL ENGINEER WITH THE
EXCEPTION OF THE NPDES CONSTRUCTION PERMIT, WHICH THE
CONTRACTOR MUST COORDINATE DIRECTLY WITH FDEP, SEE EROSION
CONTROL NOTE 6, THIS SHEET, AND SPECIFICATION SECTION 01 00 00.
ADDITIONAL SPECIAL CONTRACT REQUIREMENTS AND 01 57 19
TEMPORARY ENVIRONMENTAL CONTROLS. THE CONTRACTOR IS NOT TO
CONTACT OR COORDINATE ANY OTHER PERMITTING / REGULATORY
ACTIVITY WITHOUT PRIOR APPROVAL BY EGLIN AFB.
DEMOLITION:
1. THE CONTRACTOR SHALL OBTAIN NECESSARY PERMITS AND LICENSES
FOR PERFORMING THE DEMOLITION WORK AND SHALL FURNISH A COPY
OF SAME TO THE COR PRIOR TO COMMENCING THE WORK. THE
CONTRACTOR SHALL COMPLY WITH THE REQUIREMENTS OF THE PERMITS.
2. THE CONTRACTOR SHALL NOTIFY ALL UTILITY COMPANIES OR LOCAL
AUTHORITIES FURNISHING ELECTRICAL, POWER SERVICE SO THEY CAN
REMOVE, RELOCATE, DISCONNECT, CAP OR PLUG THEIR EQUIPMENT IN
ORDER TO FACILITATE DEMOLITION. ALL OTHER UTILITIES (WATER,
TELEPHONE OR SEWER) SHALL BE DISCONNECTED, CAPPED OR PLUGGED
BY THE CONTRACTOR AS DIRECTED BY COR REPRESENTATIVE.
3. THE PAVING MARKED FOR DEMOLITION WHICH INCLUDES ALL ASPHALT,
CONCRETE, BASE, AND RETAINING WALLS (INCLUDING THE FOOTERS)
SHALL BE REMOVED.
4. ANY TREES MARKED FOR DEMOLITION, WHICH INCLUDES THE ROOTS
ASSOCIATED WITH THE TREE SHALL BE FULLY REMOVED. TREES NOT
MARKED FOR REMOVAL SHALL BE PROTECTED FROM DAMAGE.
5. SAW-CUT A SMOOTH STRAIGHT EDGE ON ANY PAVEMENT PROPOSED FOR
DEMOLITION PRIOR TO ITS REMOVAL. PRIOR TO CONNECTING PROPOSED
PAVEMENT TO EXISTING PAVEMENT, THE CONTRACTOR SHALL ENSURE
THAT THE EDGE OF THE EXISTING PAVEMENT IS STRAIGHT AND UNIFORM
PRIOR TO REPAVING.
6. CONTRACTOR TO DIVERT A MINIMUM OF 50%, AND PREFERABLY 75% IF
POSSIBLE, OF THE SOLID WASTE FROM THE LANDFILL. RECYCLE MATERIAL
TO BE SEPARATED AND DIVERTED TO RECYCLING FACILITY.
7. ALL MATERIAL SUCH AS ASPHALT AND CONCRETE SHALL BE STOCKPILED
AND REUSED ON SITE WHERE PRACTICAL. ALL EXCESS WASTE /
RECYCLED MATERIAL NOT RE-USED SHALL BE PROPERLY DISPOSED OF
OFF BASE AT AN APPROVED FACILITY.
OTHER UTILITY INFORMATION:
1. CONTRACTOR SHALL APPLY FOR AN EGLIN AFB DIG PERMIT BEFORE ANY
EXCAVATION IS BEGUN ON THE PROJECT.
2. LANDSCAPING SHALL NOT BE LOCATED WITHIN 3 FEET OF ANY FIRE
HYDRANT AND/OR FIRE DEPARTMENT CONNECTION.
3. WATER FOR FIRE FIGHTING PURPOSES SHALL BE AVAILABLE PRIOR TO
COMBUSTIBLES BEING BROUGHT ON SITE.
STORM DRAINAGE CONSTRUCTION NOTES:
1. UNLESS OTHERWISE NOTED, ALL STORM STRUCTURES SHALL MEET FDOT
STANDARDS.
2. UNLESS OTHERWISE NOTED ON THE PLANS STORM INLETS, MANHOLES,
AND CATCH BASINS SHALL BE PRE-CAST REINFORCED CONCRETE
STRUCTURES OR APPROPRIATE HDPE STRUCTURES SHALL BE REQUIRED
AT EACH CHANGE OF PIPE SIZE, CHANGE IN PIPE DIRECTION, OR PIPE
MATERIAL.
3. ALL SWALES, DITCHES MAXIMUM SIDE AND BACK SLOPES MUST NOT BE
GREATER THAN 4 TO 1, UNLESS OTHERWISE SPECIFIED ON THE PLAN
SHEETS AND SUFFICIENT STABILIZATION IS PROVIDED.
4. CONCRETE CURBS SHALL BE SAW CUT 1/4" AT INTERVALS OF TEN FEET
(10') WITH EXPANSION JOINTS AT STREET INTERSECTIONS, STRUCTURES,
AND ALONG CURVES AT SIXTY FEET (60') INTERVALS. ALL EXPANSION
JOINT MATERIAL IS REQUIRED TO BE INSTALLED THROUGH THE ENTIRE
DEPTH OF THE CONCRETE CURB.
5. ORDER OF CONSTRUCTION ACTIVITIES SHALL BE APPROVED BY COR
PRIOR TO CONSTRUCTION.
EARTHWORK, GRADING, STABILIZATION, PAVING AND DRAINAGE:
1. ALL ORGANIC SOILS BELOW UTILITY TRENCHES, PAVEMENT AND
BUILDINGS, SHALL BE REMOVED AND REPLACED WITH SUITABLE MATERIAL
AND COMPACTED TO NO LESS THAN 95% OF THE MODIFIED PROCTOR
MAXIMUM DENSITY (ASTM D-1557).
2. ALL PAVEMENT MARKINGS SHALL BE NON-REFLECTORIZED PAINT UNLESS
OTHER WISE NOTED.
3. THE REINFORCED CONCRETE PIPE SHALL BE CLASS III WITH WALL
THICKNESS "B" CONFORMING TO ASTM C - 76 OR AWWA 302 - 74 AND
GASKETS SHALL BE IN ACCORDANCE WITH ASTM C - 443 OR ASTM D - 412.
4. ALL PIPE CALL OUTS ARE MEASURED CENTER LINE TO CENTER LINE FOR
MANHOLES AND INLETS AND FROM THE END OF THE PIPE FOR MITERED
END SECTIONS.
5. DEWATERING MAY BE REQUIRED. SPECIAL CONDITIONS WILL BE
NECESSARY FOR DEWATERING IF REQUIRED (SEE SPECIFICATIONS).
6. ALL UTILITY PIPES SHALL HAVE 3 FEET MINIMUM COVER UNLESS
OTHERWISE SPECIFIED IN PLANS.
7. PLANS AND SPECIFICATIONS REQUIRE THAT COMPACTED BACKFILL BE
PLACED ALONG SIDE OF AND OVER ALL UTILITIES. TESTING SHALL BE PER
ASUS SPECIFICATIONS AND DETAILS AND CONTRACT SPECIFICATION
SECTION 31 00 00 - EARTHWORK .
8. INSTALL AND MAINTAIN GRASS OR SOD ON EXPOSED SLOPES WITHIN 48
HOURS OF COMPLETED FINAL GRADES, AS NOTED ON PLANS, AND AT ANY
OTHER TIME AS NECESSARY TO PREVENT EROSION, SEDIMENTATION OR
TURBID DISCHARGES TO ANY DOWNSTREAM WATER BODY, WETLAND, OR
OFF-SITE PROPERTY. SODDING ON SLOPES 3:1 AND STEEPER SHALL BE
STAKED.
9. THE CONTRACTOR SHALL TAKE ALL MEASURES NECESSARY TO CONTROL
TURBIDITY AND SEDIMENT INCLUDING, BUT NOT LIMITED TO, THE
INSTALLATION OF TURBIDITY BARRIERS AND SILT FENCES AT ALL
LOCATIONS WHERE THE POSSIBILITY OF TRANSFERRING SUSPENDED
SOLIDS INTO THE RECEIVING WATER BODY EXISTS DUE TO THE
PROPOSED WORK. TURBIDITY AND SEDIMENT BARRIERS MUST BE
MAINTAINED AT ALL LOCATIONS UNTIL CONSTRUCTION IS COMPLETED
AND DISTURBED SOIL AREAS ARE STABILIZED. THE CONTRACTOR SHALL
ALSO BE RESPONSIBLE FOR REMOVING THE BARRIERS. AT NO TIME
SHALL THERE BE ANY OFFSITE DISCHARGE WHICH VIOLATES THE WATER
QUALITY STANDARDS IN CHAPTERS 62-302 AND 62-4, FLORIDA
ADMINISTRATIVE CODE.
EROSION CONTROL NOTES:
1. TEMPORARY STABILIZATION IS REQUIRED OF ALL SOIL LEFT BARE.
MAXIMUM TIME FOR BARE SOIL WITHOUT COVER WILL BE 14 DAYS.
2. PERMANENT SOIL STABILIZATION REQUIRED FOR ALL DISTURBED AREAS
OF THE SITE.
3. STORMWATER INLETS AND STRUCTURES SHOULD BE PROTECTED FROM
SOIL DEPOSITION FIRST, TO PREVENT SOIL LOSS DURING THE
CONSTRUCTION PROCESS.
4. REQUIRED INSPECTIONS BY CONTRACTOR DURING CONSTRUCTION:
a. ONCE EACH WEEK OR WITHIN 24 HRS OF A STORM EVENT
(GREATER THAN 1/2 IN.) INSPECT ALL CONTROL MEASURES.
b. REPAIR ALL DAMAGED AREAS WITHIN 24 HRS OF
DISCOVERY.
c. REMOVE ANY BUILT-UP SEDIMENT AROUND FENCES THAT
REACHES 1/3 OF THE SILT FENCE HEIGHT, REMOVE
SEDIMENT THAT COLLECTS IN DRAINAGE BASINS AND
EXFILTRATION TRENCHES.
d. SILT FENCES SHOULD BE INSPECTED FOR DEPTH OF
SEDIMENT AND TEARS TO INSURE FABRIC HAS NOT PULLED
AWAY FROM POSTS.
e. INSPECT ALL TEMPORARY AND PERMANENT SOIL
STABILIZATION FOR WASHOUTS OR BARE SPOTS.
f. INSPECTION REPORTS MUST BE AVAILABLE FOR
INSPECTION AT ALL TIMES. THE SITE SUPERINTENDENT OR
QUALIFIED STORMWATER INSPECTOR SHALL CONDUCT ALL
INSPECTIONS AND MAINTAIN REPORTS.
g. DATES OF ALL MAJOR GRADING ACTIVITIES MUST BE
RECORDED AND MAINTAINED WITH SITE INSPECTIONS WHEN
MAJOR GRADING HAS CEASED IN ANY AREA, THE DATE
MUST ALSO BE RECORDED.
h. INSPECTION AND RECORD KEEPING SHALL BE IN
ACCORDANCE WITH THE PROJECT NPDES PERMIT
REQUIRED TO BE OBTAINED THROUGH FDEP.
5. GOOD HOUSEKEEPING. THE SITE SHOULD BE KEPT IN AN ORDERLY
FASHION, THE CONTRACTOR SHALL INSURE THE FOLLOWING ITEMS ARE
ADDRESSED.
a. AN EFFORT TO STORE ONLY WHAT IS NEEDED ON THE SITE.
b. KEEP ALL STORED MATERIALS IN A NEAT AND ORDERLY
FASHION IN THE ORIGINAL CONTAINERS WHEN POSSIBLE.
c. FOLLOW ALL MANUFACTURERS RECOMMENDED
PROCEDURES FOR DISPOSAL OF WASTE MATERIAL.
d. INSPECT DAILY TO ENSURE WASTE MATERIAL IS DISPOSED
OF PROPERLY.
6. THIS PROJECT HAS GREATER THAN ONE ACRE OF DISTURBED SOIL AND
REQUIRES AN NPDES PERMIT. SWPPP WILL BE PREPARED BY THE
CONTRACTOR AND MUST BE SIGNED BY THE CONTRACTOR AND
SUB-CONTRACTORS FOR COMPLIANCE BEFORE THE NTP IS APPROVED.
CONTRACTOR WILL PREPARE THE NOI APPLICATION, SHALL BE THE
SIGNATORY AUTHORITY / APPLICANT AND SHALL SUBMIT FOR THE NPDES
PERMIT THROUGH FDEP, ONCE APPROVED BY COR REPRESENTATIVE.
CONTRACTOR TO VERIFY THE PROJECT SWPPP IS IN ACCORDANCE WITH
(IAW) THE OVERALL EGLIN AFB SWPPP.
SPILL CONTROL NOTES:
1. IN ADDITION TO THE GOOD HOUSEKEEPING AND MATERIAL MANAGEMENT
PRACTICES DISCUSSED IN THE PREVIOUS NOTES OF THIS PLAN, THE
FOLLOWING PRACTICES WILL BE FOLLOWED FOR SPILL PREVENTION AND
CLEANUP IAW PROJECT SPECIFICATION SECTION 01 57 19.
a. ALL SPILLS WILL BE REPORTED TO THE AIR FORCE
IMMEDIATELY TO EGLIN AFB ENVIRONMENTAL DEPARTMENT
(850.240.1628) PRIOR TO ANY CLEAN UP, AND IF AN
IMMEDIATE EMERGENCY CALL 911 FIRST. POINT OF
CONTACT IS ROBERT (BRUCE) STIPPICH.
b. ALL SPILL PREVENTION, CONTROL, CLEAN UP AND/OR
DISPOSAL SHALL BE IAW PROJECT SPECIFICATION SECTION
01 57 19.
SURVEY:
1. HORIZONTAL COORDINATES BASED ON FLORIDA STATE PLANE - NORTH
ZONE (NAD83), US SURVEY FEET. SURVEY PERFORMED BY SAM, LLC.
2. ELEVATIONS ARE BASED ON NORTH AMERICAN VERTICAL DATUM OF 1988
(NAVD88) UNITED STATES COASTAL AND GEODETIC SURVEY (U.S.C. & G.S.),
AS DETERMINED BY SAM, LLC.
3. CONTRACTOR IS RESPONSIBLE FOR PROTECTION OF ALL SURVEY AND
PROPERTY MONUMENTS. IF A MONUMENT IS DISTURBED, THE
CONTRACTOR SHALL CONTRACT WITH THE SURVEYOR OF RECORD FOR
REINSTALLATION OF THE MONUMENT.
4. ALL CONSTRUCTION LINES AND GRADES SHALL BE ESTABLISHED AND
MAINTAINED BY THE CONTRACTOR.
OUTAGES:
1. CONTRACTOR SHALL COORDINATE ALL UTILITY OUTAGES A MINIMUM OF 14
WORKING DAYS PRIOR TO THE SCHEDULED EVENT WITH COR
REPRESENTATIVE AND ASUS.
2. TEMPORARY UTILITY TIE-INS: FOR TEMPORARY UTILITY TIE-INS, (I.E.
CONTRACT'S TRAILER) ELECTRICITY AND POTABLE WATER ARE USUALLY
AVAILABLE ON EGLIN AND THE CONTRACTOR MAY TIE INTO THESE. BOTH
TIE-INS MUST MEET CODE REQUIREMENTS, MUST BE METERED WITH
APPROVED REMOTE READABLE METERS, AND THE CONTRACTOR SHALL
PROVIDE ALL MANPOWER/EQUIPMENT FOR THESE TIE-INS. EGLIN WILL
ONLY PERFORM THE FINAL ELECTRICAL TIE-IN TO BASE LINES; ALL OTHER
WORK WILL BE ACCOMPLISHED BY THE CONTRACTOR.
3. CONTRACTOR AWARDED THIS PROJECT IS RESPONSIBLE FOR
MONITORING CONSTRUCTION AND SUBMITTING TO THE DISTRICT/FDEP
NOTICE OF CONSTRUCTION COMMENCEMENT AND AS-BUILT
CERTIFICATIONS FOR THE PROJECT WHEN COMPLETED THE CONTRACTOR
SHALL UTILIZE A…