This document outlines points of demarcation for utility services at federal facilities. It provides guidance on where responsibility transfers between the utility provider and customer for water, electrical, and natural gas connections. For water, the point of demarcation is typically the water meter, backflow device or valve located within 25 feet of the structure. For electrical, the demarcation depends on factors like transformer location and presence of a meter, but includes the transformer terminals, meter, weatherhead or isolation device. The natural gas demarcation is the downstream side of the pressure regulator or closest apparatus to the exterior of the structure. The related federal contract opportunity is a presolicitation for installation support services at US Army facilities in Huntsville, Alabama. The services include maintenance, utilities operations, supply, transportation and administration to support missions. Questions must be submitted by email to the specified POC by the listed date.
View the file
Other files
Show 40 more
Latest 50 of 59 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Water
Point of Demarcation Applicable Scenario Sketch
Water Meter or Backflow
Device, or Valve (closest apparatus to the exterior of the structure).
Water meter, backflow device, or valve is located on the service line entering the structure within 25 feet of the exterior of the structure.
Structure
Service
Line
Point of
Demarcation
Distribution
Pipe
Distribution
Pipe
Water Meter
Point 10 feet from where the service line enters the structure.
No water meter, backflow device, or valve exists on the service line entering the structure.
Structure
Service
Line
Point of
Demarcation
Distribution
Pipe
Distribution
Pipe
Please Note: If any service is privatized, demarcations could change.
Technical Exhibit #30 Points of Demarcation 10 Sep 19
Electrical
Point of demarcation is the transformer secondary terminal spade.
Pad Mounted Transformer located outside of structure with underground service to the structure and no meter exists.
Down current side of the meter
Residential service (less than 200 amps and 240V 1-Phase), and three phase self contained meter installations. Electric Meter exists within five feet of the exterior of the building on an underground secondary line.
Point of demarcation is the meter.
Three Phase CT metered service.
Secondary terminal of the transformer inside of the structure
Transformer located inside of structure and an isolation device is in place with or without a meter
Note: Utility Owner is granted 24-hour access to transformer room.
Secondary terminal of the transformer inside of the structure
Transformer located inside of structure with no isolation device in place.
Note: Utility Owner is granted 24-hour access to transformer room.
Structure
Service
Line
Point of
Demarcation
Distribution Line
Distribution Line
S P
Structure
Pad Mounted
Transformer
Point of
Demarcation
Distribution Line
Distribution Line
S P
Meter
Structure
Pad Mounted
Transformer
Point of
Demarcation
Distribution Line
Distribution Line
S P
Meter
Structure
Service
LinePoint of Demarcation
Distribution Line
Distribution Line
S P
Isolation
Device
Structure
Service
LinePoint of Demarcation
Distribution Line
Distribution Line
S P
Please Note: If any service is privatized, demarcations could change.
Electrical (Cont’d)
Point of demarcation is the meter.
Electric meter is connected to the exterior of the building on an overhead secondary line.
Point of demarcation is the point where the overhead conductor is connected to the weather head.
Pole Mounted Transformer located outside of structure with secondary attached to outside of structure with no meter.
Service
Line
Point of
Demarcation
Utility
Pole
Pole Mounted
Transformer
Structure
Point of demarcation is the point where the overhead conductor is connected to the weather head.
Service may be overhead or underground. A disconnect switch or junction box is mounted to the exterior of the structure with no meter.
Service
Line
Point of
Demarcation
Utility
Pole
Pole Mounted
Transformer
Structure
Meter
Service
Line
Point of
Demarcation
Utility
Pole
Pole Mounted
Transformer
Structure
Disconnect or
Junction Box
Please Note: If any service is privatized, demarcations could change.
Natural Gas
The point of demarcation is the downstream side of the pressure regulator.
Natural gas service to the structure is regulated but not metered.
Structure
Service Line
Point of
Demarcation
Distribution
Line
Distribution
Line
Pressure
Regulator
The point of demarcation is the downstream side of the closest apparatus to the exterior of the structure.
More than one apparatus is connected to the service line feeding the structure.
Structure
Service
Line
Point of Demarcation Distribution Line
Distribution Line
Meter
Pressure Regulator
Please Note: If any service is privatized, demarcations could change.