Roof_System_data.pdf
PDF 278 KB Posted
- Solicitation number
- W91248-17-R-0001
About this file
Roof system
View the file
Other files
Show 40 more
Latest 50 of 60 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Attributes Advantages
Gauge 24 gauge (standard) 22 gauge (available on special request)
Length 55' maximum is standard but longer lengths available by special request
Dimensions 24" wide by 3" high (standard) 18" and 12" also available
Finish Galvalume Plus® Signature® 200 Colors Signature® 300 Colors
Fasteners Concealed fastening system. The clips are available as sliding or fixed. Two different clip heights are available to allow for thermal blocks.
Usage This panel is a structural panel that spans up to five feet on purlins, or can be used as an architectural panel over solid deck. This flat panel is designed with striations as an option to minimize oil-canning.
Limitations Recommended for roof slopes of ¼:12 or greater.
When using the fixed clip, we recommend for symmetrical double slope buildings 200' wide or less and single slope buildings 100' wide or less. (May vary upon extreme weather conditions.) Oil-canning is not a reason for rejection.
Description Ultra-Dek® is a metal standing seam roofing product attached by using a variety of concealed, interlocking clips that provide for minimum panel penetrations. The Ultra-Dek® panel can be used on new construction as well as retrofit on existing structures. This panel is designed to provide a high degree of weather tightness and has been tested by independent laboratories in accordance with ASTM E1680 and E1646 (for air infiltration and water penetration).
Ultra-Dek® Standing Seam Roof System
In su la te d Pa ne l
Sy st em s
St an di ng
S ea m
Ro of
S ys te m
Ro of a nd
W al l Sy st em s
1. No panel penetration is required over the building envelope other than at the end laps, and panel ends which are connected by a compression joint
2. Panel side laps arrive at the job site containing a sealant
3. Factory notched at both ends with pre-punched holes
4. End laps have a 16 gauge backup plate with pre-punched holes
5. High or low clips
6. UL® 90
7. Panels interlock by snapping together
1. Specially designed to seal out the elements
2. Contributes to the system’s weather tight construction and ease of installation
3. Field installation can commence or finish from either end of the building
4. Solid connection at end laps and proper fastener spacing, the pre-punched holes improve installation and ensure proper panel placement
5. Accommodates variety of insulation systems including 1" thermal spacers at the purlin
6. Lower insurance costs
7. No need for seaming equipment and ease of installation
BTerzo Highlight
Roof and W all
System s
Standing Seam
Roof System s
Insulated Panel System s
The engineering data contained herein is for the expressed use of customers and design professionals.
Along with this data, it is recommended that the design professional have a copy of the most current version of the North American Specification of Cold-Formed Steel Structural Members published by the
American Iron and Steel Institute to facilitate design. This specification contains the design criteria for cold-formed steel components. Along with the specification, the designer should reference the most current building code applicable to the project jobsite in order to determine environmental loads. If fur ther information or guidance regarding cold-formed design practices is desired, please contact the manufacturer.
EFFECTIVE noVEmbEr 3, 2004 SUbJECT To CHAnGE WITHoUT noTICE
Ultra-Dek® is a registered trademark of the NCI Group, Inc.
Galvalume Plus® is a registered trademark of BIEC International, Inc.
Signature® is a registered trademark of the NCI Group, Inc.
Allowable Uniform Loads In Pounds Per Square Foot - 24" Coverage
UltraDek® - Section Properties - 24” Coverage
Ultra-Dek® Standing Seam Roof System
24 Gauge (Fy = 50 Ksi)
SPAN
TYPE
LOAD
TYPE
SUPPORT SPACING
2.5 3.0 3.5 4.0 4.5 5.0 5.5
SINGLE LIvE LOAD 204.0 170.0 145.7 127..5 113.3 92.1 76.1
2-SPAN LIvE LOAD 204.0 170.0 145.7 118.7 93.8 75.9 62.8
3-SPAN LIvE LOAD 204.0 170.0 145.7 127.5 113.3 94.9 78.4
4-SPAN LIvE LOAD 204.0 170.0 145.7 127.5 109.4 88.6 73.2
22 Gauge (Fy = 50 Ksi)
SPAN
TYPE
LOAD
TYPE
SUPPORT SPACING
2.5 3.0 3.5 4.0 4.5 5.0 5.5
SINGLE LIvE LOAD 296.9 247.5 212.1 185.6 148.2 120.1 99.2
2-SPAN LIvE LOAD 296.9 247.5 212.1 166.2 131.3 106.3 87.9
3-SPAN LIvE LOAD 296.9 247.5 212.1 185.6 164.1 132.9 109.9
4-SPAN LIvE LOAD 296.9 247.5 212.1 185.6 152.3 124.1 102.6
NEGATIVE BENDING POSITIVE BENDING
PANEL
GAUGE
Fy
(KSI)
WEIGHT
(PSF)
Ixe
(IN.4/FT.)
Sxe
(IN.3/FT.)
Maxo
(KIP-IN.)
Ixe
(IN.4/FT.)
Sxe
(IN.3/FT.)
Maxo
(KIP-IN.)
24 50 1.23 0.135 0.0951 2.8477 0.2798 0.1153 3.4524
22 50 1.56 0.1837 0.1332 3.9877 0.39877 0.1504 4.502
8600 South I-35, Oklahoma City, OK 73149 star.marketing@starbuildings.net www.StarBuildings.com
Proper ties Notes:
1. All calculations for the properties of
Ultra-Dek® panels are calculated in accordance with the 2001 edition of the North American Specification of Cold-Formed Steel Structural Members.
2. Ixe is for deflection determination.
3. Sxe is for bending.
4. Maxo is allowable bending moment.
5. All values are for one foot of panel width.
Allowable Uniform Loads Notes:
1. Allowable loads are based on uniform span lengths and Fy = 50 ksi.
2. LIVE LOAD is limited by bending, shear, combined shear and bending.
3. Allowable loads consider a maximum deflection ratio of L/180.
4. The weight of the panel has not been deducted from the allowable loads.
5. THE ALLOWABLE UNIFORM LOADS ARE
NOT FOR USE WHEN DESIGNING PANELS
TO RESIST WIND UPLIFT.
6. Please contact manufacturer or manufacturer’s website for most current allowable wind uplift loads.