Fort Campbell Summary List of Suspect Asbestos Materials Site: Ft. Campbell Bldg ID: Building 39, New York Ave.
Ft. Campbell, KY 42223-5130
HM Material Description Floor Location(s) Contains Asbestos Lab Results
1 Transite Board, 1 Crawlspace Yes 55% Chrysotile
2 Wallboard, Drywall 1 Boiler Room No No ACM Detected
3 Wallboard, Drywall 1,2 Throughout No No ACM Detected
4 Pipe Insulation, Cal Block 1 Boiler Room No No ACM Detected
5 Pipe Insulation, Cal Block 1,2 1st & 2nd Floor Utility Rooms No No ACM Detected
6 Pipe Insulation, Cal Block 1 Crawlspace No No ACM Detected
7 Ceiling Tile, 2x2 Fissures 1,2 1st & 2nd Floors No No ACM Detected
8 Ceiling Tile, 2x2 Pinhole 1,2 1st & 2nd Floors No No ACM Detected
9 Flexible Duct, 1 1st Floor Utility Room Yes 60% Chrysotile
10 Flashing, Roofing Roof Attic Yes 10% Chrysotile
11 Floor Tile, 1X1 Green 1 1st Floor Under Carpet Yes 2% Chrysotile
12 Linoleum, Dark FL- Sheeting 1 Under Carpet in Stairwel No No ACM Detected
13 Linoleum, FS Dark 2 Under Carpet No No ACM Detected
14 Pipe Insulation, Pipe Tape Wrap 2 2nd Floor Utility Room No No ACM Detected
15 Flexible Duct, 2 2nd Floor Utility Room Yes 60% Chrysotile
16 Linoleum, Gray FL Sheeting 1 1st Floor Under Carpet No No ACM Detected
17 Mudded Joint Fittings, Mud on Cal 1,2 Utility / Boiler Rooms No No ACM Detected
18 Floor Tile, 1x1 White 1 Under Admin Carpet Yes 10% Chrysotile
19 Floor Tile, 9X9 Green w/ streaks 1 1st Floor Under Carpet Yes 10% Chrysotile
Summary List of Suspect Asbestos Materials Site: Ft. Campbell Bldg ID: Building 39, New York Ave.
Ft. Campbell, KY 42223-5130
HM Material Description Floor Location(s) Contains Asbestos Lab Results
20 Floor Tile, 9x9 Maroon 1 1st Floor Under Rug Yes 10% Chrysotile
21 Miscellaneous , Stair Tread 1,2 Stairwells No No ACM Detected
22 Floor Tile, 1x1 Whte 2 Under Conf. Room Yes 10% Chrysotile
23 Roofing Felt, Roof Roof No No ACM Detected
24 Drywall And Joint Compound, Tape and Mud
1,2 Throughout No No ACM Detected
25 Ceiling Tile, 2x4 Fissures 2 2ND Floor Hallway No No ACM Detected
26 Linoleum, Cream W/ Blu&Gry St 1,2 Scattered T/O No No ACM Detected
27 Wall Acoustic Tile, Acoustical panel uniform perforations
1 Southwest portion of building No No ACM Detected
28 Wall Acoustic Tile, Acoustical panel no perforations
1 Soutwest portion of building No No ACM Detected
29 Wall Acoustic Tile, Acoustical panel irregular perforations
1 Southwest portion of building No No ACM Detected
30 Floor Tile, White 9X9 with green streaks & 2 mastics
1 Small portion of southwest portion of building
Yes 10% Chrysotile
31 Floor Tile, 1x1 Beige w/ brown & gold fleck 1 Southwest portion of building in office for Sp 2008 renovation
No No ACM Detected
32 Floor Tile, White w/ green streaks size uncertain
1 Southwest portion of building under some walls
Yes 10% Chrysotile
Details for Suspect Asbestos Materials Site: Ft. Campbell Bldg ID: Building 39, New York Ave.
Ft. Campbell, KY 42223-5130
HM
Transite Board, Material Description
Floor
Crawlspace Location(s)
Yes
Contains Asbestos
55% Chrysotile
Content
Quantity 300 Square Feet
Friability Non-Friable
EPA Category Category II
Assessment Material with potential damage
Rec. Response Manage In Place
Good 1CONDITION
HM
Wallboard, Drywall
Material Description
Floor
Boiler Room Location(s)
No
Contains Asbestos
No ACM Detected
Content
Quantity Square Feet
Friability Non-Friable
EPA Category Category II
Assessment Material with potential damage
Rec. Response No response Required
Good 1CONDITION
HM
Wallboard, Drywall
Material Description
1,2 Floor
Throughout Location(s)
No
Contains Asbestos
No ACM Detected
Content
Quantity Square Feet
Friability Non-Friable
EPA Category Category II
Assessment Material with potential damage
Rec. Response No response Required
Good 1CONDITION
6/15/2015 Page 1
Site: Ft. Campbell Bldg ID: Building 39, New York Ave.
Ft. Campbell, KY 42223-5130
HM
Pipe Insulation, Cal Block
Material Description
Floor
Boiler Room Location(s)
No
Contains Asbestos
No ACM Detected
Content
Quantity Linear Feet
Friability Friable
EPA Category Friable
Assessment Material with potential damage
Rec. Response No response Required
Good 1CONDITION
HM
Pipe Insulation, Cal Block
Material Description
1,2 Floor
1st & 2nd Floor Utility Rooms Location(s)
No
Contains Asbestos
No ACM Detected
Content
Quantity Linear Feet
Friability Friable
EPA Category Friable
Assessment Material with potential damage
Rec. Response No response Required
Good 1CONDITION
HM
Pipe Insulation, Cal Block
Material Description
Floor
Crawlspace Location(s)
No
Contains Asbestos
No ACM Detected
Content
Quantity Linear Feet
Friability Friable
EPA Category Friable
Assessment Material with potential damage
Rec. Response No response Required
6/15/2015 Page 2
Site: Ft. Campbell Bldg ID: Building 39, New York Ave.
Ft. Campbell, KY 42223-5130
HM
Ceiling Tile, 2x2 Fissures
Material Description
1,2 Floor
1st & 2nd Floors Location(s)
No
Contains Asbestos
No ACM Detected
Content
Quantity Square Feet
Friability Friable
EPA Category Friable
Assessment Material with potential damage
Rec. Response No response Required
Good 1CONDITION
HM
Ceiling Tile, 2x2 Pinhole
Material Description
1,2 Floor
1st & 2nd Floors Location(s)
No
Contains Asbestos
No ACM Detected
Content
Quantity Square Feet
Friability Friable
EPA Category Friable
Assessment Material with potential damage
Rec. Response No response Required
Good 1CONDITION
HM
Flexible Duct, Material Description
Floor
1st Floor Utility Room Location(s)
Yes
Contains Asbestos
60% Chrysotile
Content
Quantity 8 Linear Feet
Friability Non-Friable
EPA Category Category II
Assessment Material with potential damage
Rec. Response Manage In Place
6/15/2015 Page 3
Site: Ft. Campbell Bldg ID: Building 39, New York Ave.
Ft. Campbell, KY 42223-5130
HM
Flashing, Roofing
Material Description
Roof Floor
Attic Location(s)
Yes
Contains Asbestos
10% Chrysotile
Content
Quantity 25 Square Feet
Friability Non-Friable
EPA Category Categpry I
Assessment Material with potential damage
Rec. Response Manage In Place
Good 1CONDITION
HM
Floor Tile, 1X1 Green
Material Description
Floor
1st Floor Under Carpet Location(s)
Yes
Contains Asbestos
2% Chrysotile
Content
Quantity 49 Square Feet
Friability Non-Friable
EPA Category Category I
Assessment Nonfriable material with potential for damage
Rec. Response Manage In Place
Good 1CONDITION
Mastic Only Positive
HM
Linoleum, Dark FL- Sheeting
Material Description
Floor
Under Carpet in Stairwel Location(s)
No
Contains Asbestos
No ACM Detected
Content
Quantity Square Feet
Friability Non-Friable
EPA Category Category I
Assessment Nonfriable material with potential for damage
Rec. Response No response Required
6/15/2015 Page 4
Site: Ft. Campbell Bldg ID: Building 39, New York Ave.
Ft. Campbell, KY 42223-5130
HM
Linoleum, FS Dark
Material Description
Floor
Under Carpet Location(s)
No
Contains Asbestos
No ACM Detected
Content
Quantity Square Feet
Friability Non-Friable
EPA Category Category I
Assessment Nonfriable material with potential for damage
Rec. Response No response Required
Good 1CONDITION
HM
Pipe Insulation, Pipe Tape Wrap
Material Description
Floor
2nd Floor Utility Room Location(s)
No
Contains Asbestos
No ACM Detected
Content
Quantity Linear Feet
Friability Friable
EPA Category Friable
Assessment Material with potential damage
Rec. Response No response Required
Good 1CONDITION
HM
Flexible Duct, Material Description
Floor
2nd Floor Utility Room Location(s)
Yes
Contains Asbestos
60% Chrysotile
Content
Quantity 8 Linear Feet
Friability Non-Friable
EPA Category Category II
Assessment Material with potential damage
Rec. Response Manage In Place
6/15/2015 Page 5
Site: Ft. Campbell Bldg ID: Building 39, New York Ave.
Ft. Campbell, KY 42223-5130
HM
Linoleum, Gray FL Sheeting
Material Description
Floor
1st Floor Under Carpet Location(s)
No
Contains Asbestos
No ACM Detected
Content
Quantity Square Feet
Friability Non-Friable
EPA Category Category I
Assessment Nonfriable material with potential for damage
Rec. Response No response Required
Good 1CONDITION
HM
Mudded Joint Fittings, Mud on Cal
Material Description
1,2 Floor
Utility / Boiler Rooms Location(s)
No
Contains Asbestos
No ACM Detected
Content
Quantity Each
Friability Friable
EPA Category Friable
Assessment Material with potential damage
Rec. Response No response Required
Good 1CONDITION
HM
Floor Tile, 1x1 White
Material Description
Floor
Under Admin Carpet Location(s)
Yes
Contains Asbestos
10% Chrysotile
Content
Quantity 210 Square Feet
Friability Non-Friable
EPA Category Category I
Assessment Nonfriable material with potential for damage
Rec. Response Operations and Maintenance 1
Good 1CONDITION
Overlaid on a 9x9 Green Floor Tile
6/15/2015 Page 6
Site: Ft. Campbell Bldg ID: Building 39, New York Ave.
Ft. Campbell, KY 42223-5130
HM
Floor Tile, 9X9 Green w/ streaks
Material Description
Floor
1st Floor Under Carpet Location(s)
Yes
Contains Asbestos
10% Chrysotile
Content
Quantity 509 Square Feet
Friability Non-Friable
EPA Category Category I
Assessment Nonfriable material with potential for damage
Rec. Response Manage In Place
Good 1CONDITION
Tile and Mastic Positive
HM
Floor Tile, 9x9 Maroon
Material Description
Floor
1st Floor Under Rug Location(s)
Yes
Contains Asbestos
10% Chrysotile
Content
Quantity 480 Square Feet
Friability Non-Friable
EPA Category Category I
Assessment Nonfriable material with potential for damage
Rec. Response Manage In Place
Good 1CONDITION
Tile Only Positive
HM
Miscellaneous , Stair Tread
Material Description
1,2 Floor
Stairwells Location(s)
No
Contains Asbestos
No ACM Detected
Content
Quantity Each
Friability Non-Friable
EPA Category Categpry I
Assessment Nonfriable material with potential for damage
Rec. Response No response Required
6/15/2015 Page 7
Site: Ft. Campbell Bldg ID: Building 39, New York Ave.
Ft. Campbell, KY 42223-5130
HM
Floor Tile, 1x1 Whte
Material Description
Floor
Under Conf. Room Location(s)
Yes
Contains Asbestos
10% Chrysotile
Content
Quantity 519 Square Feet
Friability Non-Friable
EPA Category Category I
Assessment Nonfriable material with potential for damage
Rec. Response Manage In Place
Good 1CONDITION
Tile Only Positive
HM
Roofing Felt, Material Description
Roof Floor
Roof Location(s)
No
Contains Asbestos
No ACM Detected
Content
Quantity Square Feet
Friability Non-Friable
EPA Category Category I
Assessment Material with potential damage
Rec. Response No response Required
Good 1CONDITION
HM
Drywall And Joint Compound, Tape and Mud
Material Description
1,2 Floor
Throughout Location(s)
No
Contains Asbestos
No ACM Detected
Content
Quantity Square Feet
Friability Non-Friable
EPA Category Category II
Assessment Material with potential damage
Rec. Response No response Required
6/15/2015 Page 8
Site: Ft. Campbell Bldg ID: Building 39, New York Ave.
Ft. Campbell, KY 42223-5130
HM
Ceiling Tile, 2x4 Fissures
Material Description
Floor
2ND Floor Hallway Location(s)
No
Contains Asbestos
No ACM Detected
Content
Quantity Square Feet
Friability Friable
EPA Category Friable
Assessment Material with potential damage
Rec. Response No response Required
Good 1CONDITION
HM
Linoleum, Cream W/ Blu&Gry St
Material Description
1,2 Floor
Scattered T/O Location(s)
No
Contains Asbestos
No ACM Detected
Content
Quantity Square Feet
Friability Non-Friable
EPA Category Category I
Assessment Material with potential damage
Rec. Response No response Required
Good 1CONDITION
HM
Wall Acoustic Tile, Acoustical panel uniform perforations
Material Description
Floor
Southwest portion of building Location(s)
No
Contains Asbestos
No ACM Detected
Content
Quantity Square Feet
Friability Friable
EPA Category Category II
Assessment Potential for Damage
Rec. Response No response Required
FairCONDITION
Removed during Spring 2008 renovation
6/15/2015 Page 9
Site: Ft. Campbell Bldg ID: Building 39, New York Ave.
Ft. Campbell, KY 42223-5130
HM
Wall Acoustic Tile, Acoustical panel no perforations
Material Description
Floor
Soutwest portion of building Location(s)
No
Contains Asbestos
No ACM Detected
Content
Quantity Square Feet
Friability Friable
EPA Category Category II
Assessment Potential for Damage
Rec. Response No response Required
FairCONDITION
To be removed in Spring 2008 renovation
HM
Wall Acoustic Tile, Acoustical panel irregular perforations
Material Description
Floor
Southwest portion of building Location(s)
No
Contains Asbestos
No ACM Detected
Content
Quantity Square Feet
Friability Friable
EPA Category Category II
Assessment Potential for Damage
Rec. Response No response Required
Good 1CONDITION
To be removed during Spring 2008 renovation
HM
Floor Tile, White 9X9 with green streaks & 2 mastics
Material Description
Floor
Small portion of southwest portion of building Location(s)
Yes
Contains Asbestos
10% Chrysotile
Content
Quantity 1500 Square Feet
Friability Non-Friable
EPA Category Category I
Assessment Potential for Damage
Rec. Response Manage In Place
FairCONDITION
Checkerboard with green 9x9; Black mastic is ACM
6/15/2015 Page 10
Site: Ft. Campbell Bldg ID: Building 39, New York Ave.
Ft. Campbell, KY 42223-5130
HM
Floor Tile, 1x1 Beige w/ brown & gold fleck
Material Description
Floor
Southwest portion of building in office for Sp 2008 renovation Location(s)
No
Contains Asbestos
No ACM Detected
Content
Quantity Square Feet
Friability Non-Friable
EPA Category Category I
Assessment Potential for Damage
Rec. Response No response Required
Good 1CONDITION
Overlays green & white 9X9
HM
Floor Tile, White w/ green streaks size uncertain
Material Description
Floor
Southwest portion of building under some walls Location(s)
Yes
Contains Asbestos
10% Chrysotile
Content
Quantity 1500 Square Feet
Friability Non-Friable
EPA Category Category I
Assessment Potential for Damage
Rec. Response Manage In Place
FairCONDITION
6/15/2015 Page 11
Building Occupant Notification Site: Ft. Campbell Bldg ID: Building 39, New York Ave.
Ft. Campbell, KY 42223-5130
HM Material Description Location(s) Contains Asbestos ContentQuantity Floor(s)
1 Transite Board, 1 Crawlspace Yes 55% Chrysotile
Square Feet
9 Flexible Duct, 1 1st Floor Utility Room Yes 60% Chrysotile
Linear Feet
10 Flashing, Roofing Roof Attic Yes 10% Chrysotile
Square Feet
11 Floor Tile, 1X1 Green 1 1st Floor Under Carpet Yes 2% Chrysotile
Square Feet
15 Flexible Duct, 2 2nd Floor Utility Room Yes 60% Chrysotile
Linear Feet
18 Floor Tile, 1x1 White 1 Under Admin Carpet Yes 10% Chrysotile
Square Feet
19 Floor Tile, 9X9 Green w/ streaks 1 1st Floor Under Carpet Yes 10% Chrysotile
Square Feet
20 Floor Tile, 9x9 Maroon 1 1st Floor Under Rug Yes 10% Chrysotile
Square Feet
22 Floor Tile, 1x1 Whte 2 Under Conf. Room Yes 10% Chrysotile
Square Feet
30 Floor Tile, White 9X9 with green streaks & 2 mastics
1 Small portion of southwest portion of building Yes 10% Chrysotile
1,500
Square Feet
32 Floor Tile, White w/ green streaks size uncertain
1 Southwest portion of building under some walls Yes 10% Chrysotile
1,500
Square Feet
6/15/2015 Page 1
BAT
BAT Associates, Inc.
*Engineers* *Scientists* *Planners*
*Engineers*
*Engineers*
*Engineers*
*Engineers*
*Engineers*
*Engineers*
*Engineers*
*Engineers*
| 39-1-2015 |
| 39-2-2015 |
| 39-3-2015 |
| 39-4-2015 |
| 39-d-1-2015 |
| 39-d-2-2015 |
| 39-d-3-2015 |
| 39-d-4-2015 |
| 39-d-5-2015 |
| 39-d-6-2015 |
| 39-d-7-2015 |
| 39-d-8-2015 |
| 39-d-9-2015 |