A0002 SHEET A407.pdf

PDF 107 KB Posted

Attached to
AIT Barracks Fort Eustis VA (Amendment 0004) Federal contract opportunity
Solicitation number
W9123620B0015
Issued by
Department of the Army Corps of Engineers Engineering District Norfolk

About this file

This document contains drawings and specifications for accessibility details in toilet rooms for a construction project at Fort Eustis, Virginia. The solicitation is to construct AIT Barracks at Fort Eustis and includes details for toilet fixture mounting heights and clearances, typical accessibility details, and enlarged toilet room details. The opportunity is issued by the Department of the Army Corps of Engineers Norfolk District for solicitation number W9123620B0015 with an amended date of July 13, 2020. Drawings can be requested by emailing the points of contact provided. The restroom details cover dimensions for toilet and urinal placement and clearances to ensure accessibility compliance.

View the file

Other files for this federal contract opportunity

Other files attached to AIT Barracks Fort Eustis VA (Amendment 0004), newest first.
File Type Posted
B.01.02_ KO signed IFB Abstract of Offerors.pdf PDF
Amendment 4.pdf PDF
W9123620B0015 Amendment 0003.pdf PDF
A0002 SHEET A423.pdf PDF
A0002 SPEC 09 30 10.pdf PDF
A0002 SPEC 06 61 16.pdf PDF
A0002 SHEET I002.pdf PDF
A0002 SHEET F103.pdf PDF
A0002 SHEET A401.pdf PDF
W91236-20-B-0015 Amend 0002.pdf PDF
A0002 SPECS TOC.pdf PDF
A0002 Revised FFE Package.pdf PDF
A0002 SPEC 08 33 23.pdf PDF
A0002 SPEC 07 26 30.pdf PDF
A0002 SHEET F104.pdf PDF
A0002 SHEET A402.pdf PDF
A0002 SHEET A406.pdf PDF
A0002 SHEET A006.pdf PDF
A0002 SPEC 12 31 00.pdf PDF
A0002 SHEET A331.pdf PDF
A0002 SHEET A405.pdf PDF
A0002 SUBMITTAL REGISTER.pdf PDF
A0002 SHEET A404.pdf PDF
A0002 SHEET A114.pdf PDF
A0002 SHEET A002.pdf PDF
A0002 SPEC 10 11 00 .pdf PDF
A0002 SHEET A605.pdf PDF
A0002 SHEET MI802.pdf PDF
A0002 SHEET A611.pdf PDF
A0002 SHEET A601.pdf PDF
A0001 SHEET C516.pdf PDF
A0001 SHEET A401.pdf PDF
A0001 SPEC 28 31 76.pdf PDF
A0001 SHEET EG501.pdf PDF
A0001 SHEET A602.pdf PDF
A0001 SHEET LP501.pdf PDF
A0001 SHEET A406.pdf PDF
A0001 SHEET A402.pdf PDF
A0001 SHEET A114.pdf PDF
A0001 SHEET A121 THRU A151.pdf PDF
A0001 SHEET A601.pdf PDF
Amendment 1.pdf PDF
A0001 SHEET I002 AND I221.pdf PDF
A0001 SHEET A322.pdf PDF
A0001 SPEC 07 61 1400 20.pdf PDF
A0001 SHEET A611.pdf PDF
H.01.01 794_AIT_PH4_SID_RTA_SUBMITTAL.pdf PDF
H.01.01 794_AIT_PH4_SPEC_RTA_SUBMITTAL.pdf PDF
H.01.01 794_AIT_PH4_FFE_RTA_SUBMITTAL.pdf PDF
20-B-0015 Barracks AIT.pdf PDF
Show all 50

AIT Barracks Fort Eustis VA (Amendment 0004) has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TTD

2'

4"

O

PE

N

IN

G 1'

7"

T O

9"

3'

0"

TO

C

O N

TR

O

LS

4'

0" M

AX

PTD

MG

MIN

1' - 0" 3' - 6" MIN

" M

AX

" M

IN

NOTE: DIMENSIONS ARE FROM

FACE OF WALL FINISH

SD

TO

B

O

TT

O M

E D

G E

3'

4"

UON

2" TYP

SND

5'

0" N

O N

A C

C

ES

SI

BL

E H

T

4'

0" A

C C

ES

SI

BL

E

H T

RH

6'

6"

SCR

4"

FI

XT

U R

E

" M

IN

" M

AX

H

T O

F

AC

C

ES

SI

BL

E

ALIGN TOP

EDGE OF SND W/ TTD

2'

" M

AX

2'

3" M

IN

2'

5" M

IN

6" MAX

9" M

IN

" M

AX

2'

3"

8" MIN

3'

4" 1'

6"

M

IN

3' - 4"

1' - 0" MAX 3' - 6" MIN

2'

0" M

IN

1'

0"

M

IN

4' - 6" MIN

R

EF

LE

C

TI

V E

S U

R F A

C E

3'

4" T

O

LAVATORY FRONT ELEVATION & ACCESSORY ELEVATIONSWATER CLOSET & ACCESSORY ELEVATION

WATER CLOSET PLAN

FI

XT

U R

E

1'

5" M

AX

H

T O

F

AC

C

ES

SI

BL

E

URINAL ELEVATION

2'

6" M

IN

4' - 0" MIN

URINAL PLAN

ABBREVIATIONS:

GB GRAB BAR

HC ACCESSIBLE

LAV LAVATORY

MC MEDICINE CABINET

MG MIRROR GLASS

MHU MOP HOLDER WITH UTILITY SHELF

PTD PAPER TOWEL DISPENSER

PTDR PAPER TOWEL DISPENSER &

WASTE RECEPTACLE

RH ROBE HOOK

SCR SHOWER CURTAIN ROD

SD SOAP DISPENSER

SH SOAP HOLDER

SHWR HD SHOWER HEAD

SMSD SURFACE MOUNTED SOAP DISPENSER

SND SANITARY NAPKIN DISPOSAL

STD STANDARD

TB TOWELBAR

TSCD TOILET SEAT COVER DISPENSER

TTD TOILET TISSUE DISPENSER

UR URINAL

URS URINAL SCREEN

4'

0" M

IN

1' -3

" M

IN

5" M

AX

TWO STATION WATER COOLER

1'

1/

2"

1' - 6 3/8"

1' - 6 3/8"

2'

3"

2'

5/

O R

I F

IC

E H

T

2'

7/

8"

O R

I F

IC

E H

T

3'

3/

8"

2' - 6" MIN

2' - 6" MIN

3'

MC

MIN 12"

ABOVE TOP

OF

COUNTER

20 2223

M

AX

4'

0"

M

AX

4'

0"

M

AX

3'

6"

FIG. 404.2.4.1

MANEUVERING CLEARANCE AT SWINGING DOORS

(B) FRONT APPROACH, PUSH SIDE (C) HINGE APPROACH, PULL SIDE (D) HINGE APPROACH, PULL SIDE (E) HINGE APPROACH, PUSH SIDE (G) LATCH APPROACH, PUSH SIDE(F) LATCH APPROACH, PULL SIDE

(445) (305) (915) (1065) (610)

(1370)

(1

5)

(1

0)

(1

5)

(1

5)

(1

5)

(1

0)

(1

0)

(610)

(A) CIRCULAR (B) T-SHAPED

(A) FORWARD (B) PARALLEL

FIG. 304.3

SIZE OF WHEELCHAIR TURNING SPACE

FIG. 405.5

POSITION OF CLEAR FLOOR OR GROUND SPACE

(1525) (1525)

(305) (915) (305)

(760) (1220)

(9

(1

5)

(7

(1

0)

(A) FORWARD APPROACH (B) PARALLEL APPROACH

FIG. 305.7

MANEUVERING CLEARANCE IN AN ALCOVE

(915) (1525)

(1

0) (7

(X

(X

FIG. 306.3

KNEE CLEARANCE

(205)

(280)

(6

(2

FIG. 306.2

TOE CLEARANCE

(430)

(2

(A) FRONT APPROACH, PULL SIDE

DOORS AND DOORWAYS

" M

IN

. 18" MIN.

" M

IN

36" MIN.

" M

IN

. 42" MIN.

" M

IN

" M

IN

54" MIN.

" M

IN

. 24" MIN.12" MIN.

24" MIN.

" M

IN

CLEAR FLOOR SPACE

60" MIN. 60" MIN.

" M

IN

48" MIN.

" M

IN

30" MIN.

" M

IN

" M

IN

12" MIN. 36" MIN. 12" MIN.

" M

IN

36" MIN. 60" MIN.

" M

IN

X

X

" M

IN

9" M

IN

8" MIN.

11" MIN.

9" M

IN

.17" MIN.

2' - 9 123/128"

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S D

R

AW

N B

Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

'D

D

AT

E

TI

M

E

ST

AM

P:

IS

SU

E D

AT

E:

N

AO

F

IL

E N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

SO

LI

C

IT

AT

IO

N N

O

C O

N

TR

AC

T

N O

7/

/2

1:

:0

PM

A-407

BCOF

N O

R

FO

LK

D

IS

TR

IC

T

N O

R

FO

LK

, V

A

S.

H

EN

D

R

IC

K

S.

H

EN

D

R

IC

K

D . G

EB

LE

R

D . G

EB

LE

R

FE

BR

U

AR

Y

R

TA

S U

BM

IT

TA

L

EN

LA

R G

ED

T

O

IL

ET

R

O O

M D

ET

AI

LS

JB

LE

FO

R T

EU

ST

IS

, V

IR

G

IN

IA

AI

T

BA

R

R

AC

KS

C

O M

PL

EX

P H

AS

E

-B

C O

F

PN

SCALE: NTS1 TOILET FIXTURE MOUNTING HEIGHTS AND CLEARANCES

SCALE: NTS2 TYPICAL ACCESSIBILITY DETAILS

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

AM

E N D

M

EN

T #1

J

U L

Sheets
A-407 - ENLARGED TOILET ROOM DETAILS

File details come from the government source that posted it. Updated .