This document package contains construction drawings and details for a federal solicitation seeking masonry and structural work. The drawings depict exterior wall sections, window details, shelf angles, scupper details, and air barrier transitions for new barracks at Fort Eustis, Virginia. Relevant specifications include standard face brick, through-wall flashing, closed cell spray foam insulation, gypsum sheathing and metal roof deck. The related solicitation seeks masonry, framing and roofing services for AIT Barracks at Fort Eustis, with an issuance date of February 2020. The Army Corps of Engineers Norfolk District is the contracting agency.
View the file
Other files for this federal contract opportunity
Show all 50
AIT Barracks Fort Eustis VA (Amendment 0004) has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FIRST FLOOR
0"
M
4" SPLIT FACE CMU
REFERENCE FINISH
SCHEDULE FOR
WALL BASE AND
FLOOR FINISH.
5/8" GWB
THROUGH-WALL
FLASHING
APPROX. GRADE
ADJUSTABLE
WALL TIE
3/8" MORTAR
JOINT, TYP.
3" (R-20) CLOSED
CELL SPRAY FOAM
INSULATION
WEEP @ 24" O.C.
5/8" GYPSUM
SHEATHING
GROUT SOLID
PROVIDE SILL SEAL
UNDER BOTTOM OF
STUD TRACK
MORTAR MESH
2" PERIMETER
INSULATION 24" EACH WAY TYP.
9" 3" 3"
1' - 3" M
SUSPENDED GWB CEILING
ON 1-5/8" METAL FRAMING
WITH RESILIENT
ISOLATION HANGARS @
4'-0" O.C. EACH WAY TYP.
(REF. CEILING PLANS FOR
CEILING TYPE AND HEIGHT
IN EACH SPACE)
RECESSED
SOLDIER COURSE
STEEL LINTEL
FLASHING WITH
BACKER
ROD +
SEALANT
CFMF HEADER, REF
STRUCTURAL.
WEEP @ 24" O.C.
THROUGH-WALL
FLASHING
MORTAR NET
STANDARD
FACE BRICK
ADJUSTABLE
WALL TIE
BACKER ROD + SEALANT
5/8" GWB
6" CFMF WITH CONT. R-21
BATT INSULATION
5/8" GWB SHEATHING
SHIM AS REQUIRED
CONT GWB EDGE BEAD
3/4"
9" 3" 3"
1' - 3"
FOURTH FLOOR
36' - 0"
M
SPRAY FOAM INSUL.
CONT. AT PERIMETER
AND AT ALL GAPS IN
CONSTRUCTION. REFER
TO AIR BARRIER REQS
AND DETAILS
REFERENCE FINISH
SCHEDULE FOR WALL
BASE AND FLOOR FINISH.
5/8" GWB
EXTEND GWB TO
UNDERSIDE OF DECK
METAL
ANGLE -
REFER TO
STRUCTURAL
DWGS
3" (R-20) CLOSED
CELL SPRAY
FOAM
INSULATION
STANDARD FACE
BRICK
PROVIDE SILL SEAL UNDER
BOTTOM OF STUD TRACK
BENT PLATE, REFER TO
STRUCTURAL DWGS
MORTAR MESH
THRU WALL
FLASHING W/
WEEP @ 24" O.C.
SEALANT &
BACKER ROD
MIN 1/4" THICK
COMPRESSIBLE
MATERIAL
A-611
AIR SPACE
3" 3"
ROOF BRG.
48' - 0"
6"
12"
SSMR
VAPOR PERMEABLE ROOF UNDERLAYMENT
5/8" GYPSUM SHEATHING
1 1/2" METAL ROOF DECK
R-50 BATT INSULATION
CFMF ROOF TRUSS
BRICK SOLDER COURSE
STEEL LINTEL
HSS 6X6 @ ROOF BRG.
REF STRUCTURAL
PERFORATED METAL
PANEL SOFFIT ON 2 1/2"
CFMF @ 12" O.C.
PRE-FINISHED CLOSURE
TRIM WITH CONT.
SEALANT
STANDARD FACE BRICK
MASONRY TIES
MORTAR MESH
THRU WALL FLASHING
WITH WEEP HOLE @ 24"
O.C.
THIRD FLOOR
24' - 0"
3" (R-20) CLOSED
CELL SPRAY FOAM
INSULATION
CONCRETE SLAB
ON METAL DECK
FLOOR SYSTEM
SPRAY FOAM INSUL.
CONT. AT PERIMETER
AND AT ALL GAPS IN
CONSTRUCTION.
REFER TO AIR BARRIER
REQS AND DETAILS
EXTEND GWB TO
UNDERSIDE OF DECK
5/8" GYPSUM
SHEATHING
A-331
A-331
SIM.
9" 3" 3" 1' - 3"
BENT PLATE - REFER
TO STRUCTURAL
DWGS
MIN 1/4" THICK
COMPRESSIBLE
MATERIAL
SEALANT &
BACKER ROD
MANUFACTURE
D LIPPED BRICK
SHELF ANGLE - REFER
TO STRUCTURAL DWGS
THRU WALL
FLASHING WEEP @
24" OC
MORTAR MESH
TYP. @ 3RD - 4TH
FLOOR
9" 3" 3"
1' - 3"
BITUMINOUS ROOFING
PER SPECS.
R-36
POLYISOCYANURATE
ROOF INSULATION TYP.
EXTEND ROOFING UP BACKSIDE OF
PARAPET PER ROOFING DETAILS.
FASTEN PRE-FORMED METAL SCUPPER
PER MFR.
SHINGLE FLEXIBLE FLASHING OVER
METAL DRIP FLASHING
FASTEN PRE-FINISHED METAL
SCUPPER TO PARAPET THRU
BLOCKING, CONCEAL FASTENERS
WITH DRIP FLASHING
WRAP OPENING WITH
FLEXIBLE FLASHING, ALL
AROUND
PRE-FINISHED
METAL
CONDUCTOR
HEAD (SM-1)
6"X8" RECTANGULAR
DOWNSPOUT (SM-1)
SEALANT JOINT TYP.
6"
1" 8"
6"
FLASHING OVERLAPS SCUPPER
AND FASTENERS
ROOF FLASHING
AIR BARRIER
TRANSITION MEMBRANE
SHALL OVERLAP
ROOFING MEMBRANE OR
ROOF FLASHING
MINIMUM 3".
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S D
R
AW
N B
Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
'D
D
AT
E
TI
M
E
ST
AM
P:
IS
SU
E D
AT
E:
N
AO
F
IL
E N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
7/
/2
:0 7:
P
M
A-331
BCOF
N O
R
FO
LK
D
IS
TR
IC
T
N O
R
FO
LK
, V
A
S.
H
EN
D
R
IC
K
S.
H
EN
D
R
IC
K
D . G
EB
LE
R
D . G
EB
LE
R
FE
BR
U
AR
Y
R
TA
S U
BM
IT
TA
L
SE
CT
IO
N
DE
TA
IL
S
JB
LE
FO
R T
EU
ST
IS
, V
IR
G
IN
IA
AI
T
BA
R
R
AC
KS
C
O M
PL
EX
P H
AS
E
-B
C O
F
PN
SCALE: 1 1/2" = 1'-0"
A-311
1 SECTION DETAIL
SCALE: 1 1/2" = 1'-0"
A-311
2 TYP. WINDOW HEAD DETAIL
SCALE: 1 1/2" = 1'-0"
A-311
4 SECTION DETAIL
SCALE: 1 1/2" = 1'-0"
A-311
6 SECTION DETAIL
SCALE: 1 1/2" = 1'-0"
A-311
5 SECTION DETAIL
SCALE: 3" = 1'-0"3 TYP. SHELF ANGLE DETAIL
A-331
0'
SCALE: 1-1/2" = 1' - 0"
1' 2'
0'
SCALE: 3" = 1' - 0"
6' 12'SCALE: 3" = 1'-0"7 TYP. SCUPPER W/CONDUCTOR HEAD DETAIL
A-316
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AM
E N D
M
EN
T #2
J
U L
| Sheets |
| A-006 - AIR BARRIER DETAILS |
| A-331 - SECTION DETAILS |
| A-332 - SECTION DETAILS |
| A-423 - STAIR DETAILS |
| A-605 - DOOR DETAILS |
File details come from the government source that posted it. Updated .