This document package contains construction drawings and details for a federal solicitation seeking masonry and structural work. The drawings depict exterior wall sections, window details, shelf angles, scupper details, and air barrier transitions for new barracks at Fort Eustis, Virginia. Relevant specifications include standard face brick, through-wall flashing, closed cell spray foam insulation, gypsum sheathing and metal roof deck. The related solicitation seeks masonry, framing and roofing services for AIT Barracks at Fort Eustis, with an issuance date of February 2020. The Army Corps of Engineers Norfolk District is the contracting agency.

View the file

Other files for this federal contract opportunity

Other files attached to AIT Barracks Fort Eustis VA (Amendment 0004), newest first.
File Type Posted
B.01.02_ KO signed IFB Abstract of Offerors.pdf PDF
Amendment 4.pdf PDF
W9123620B0015 Amendment 0003.pdf PDF
A0002 SHEET A423.pdf PDF
A0002 SPEC 09 30 10.pdf PDF
A0002 SPEC 06 61 16.pdf PDF
A0002 SHEET I002.pdf PDF
A0002 SHEET F103.pdf PDF
A0002 SHEET A407.pdf PDF
A0002 SHEET A401.pdf PDF
W91236-20-B-0015 Amend 0002.pdf PDF
A0002 SPECS TOC.pdf PDF
A0002 Revised FFE Package.pdf PDF
A0002 SPEC 08 33 23.pdf PDF
A0002 SPEC 07 26 30.pdf PDF
A0002 SHEET F104.pdf PDF
A0002 SHEET A402.pdf PDF
A0002 SHEET A406.pdf PDF
A0002 SHEET A006.pdf PDF
A0002 SPEC 12 31 00.pdf PDF
A0002 SHEET A405.pdf PDF
A0002 SUBMITTAL REGISTER.pdf PDF
A0002 SHEET A404.pdf PDF
A0002 SHEET A114.pdf PDF
A0002 SHEET A002.pdf PDF
A0002 SPEC 10 11 00 .pdf PDF
A0002 SHEET A605.pdf PDF
A0002 SHEET MI802.pdf PDF
A0002 SHEET A611.pdf PDF
A0002 SHEET A601.pdf PDF
A0001 SHEET C516.pdf PDF
A0001 SHEET A401.pdf PDF
A0001 SPEC 28 31 76.pdf PDF
A0001 SHEET EG501.pdf PDF
A0001 SHEET A602.pdf PDF
A0001 SHEET LP501.pdf PDF
A0001 SHEET A406.pdf PDF
A0001 SHEET A402.pdf PDF
A0001 SHEET A114.pdf PDF
A0001 SHEET A121 THRU A151.pdf PDF
A0001 SHEET A601.pdf PDF
Amendment 1.pdf PDF
A0001 SHEET I002 AND I221.pdf PDF
A0001 SHEET A322.pdf PDF
A0001 SPEC 07 61 1400 20.pdf PDF
A0001 SHEET A611.pdf PDF
H.01.01 794_AIT_PH4_SID_RTA_SUBMITTAL.pdf PDF
H.01.01 794_AIT_PH4_SPEC_RTA_SUBMITTAL.pdf PDF
H.01.01 794_AIT_PH4_FFE_RTA_SUBMITTAL.pdf PDF
20-B-0015 Barracks AIT.pdf PDF
Show all 50

AIT Barracks Fort Eustis VA (Amendment 0004) has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FIRST FLOOR

0"

M

4" SPLIT FACE CMU

REFERENCE FINISH

SCHEDULE FOR

WALL BASE AND

FLOOR FINISH.

5/8" GWB

THROUGH-WALL

FLASHING

APPROX. GRADE

ADJUSTABLE

WALL TIE

3/8" MORTAR

JOINT, TYP.

3" (R-20) CLOSED

CELL SPRAY FOAM

INSULATION

WEEP @ 24" O.C.

5/8" GYPSUM

SHEATHING

GROUT SOLID

PROVIDE SILL SEAL

UNDER BOTTOM OF

STUD TRACK

MORTAR MESH

2" PERIMETER

INSULATION 24" EACH WAY TYP.

9" 3" 3"

1' - 3" M

SUSPENDED GWB CEILING

ON 1-5/8" METAL FRAMING

WITH RESILIENT

ISOLATION HANGARS @

4'-0" O.C. EACH WAY TYP.

(REF. CEILING PLANS FOR

CEILING TYPE AND HEIGHT

IN EACH SPACE)

RECESSED

SOLDIER COURSE

STEEL LINTEL

FLASHING WITH

BACKER

ROD +

SEALANT

CFMF HEADER, REF

STRUCTURAL.

WEEP @ 24" O.C.

THROUGH-WALL

FLASHING

MORTAR NET

STANDARD

FACE BRICK

ADJUSTABLE

WALL TIE

BACKER ROD + SEALANT

5/8" GWB

6" CFMF WITH CONT. R-21

BATT INSULATION

5/8" GWB SHEATHING

SHIM AS REQUIRED

CONT GWB EDGE BEAD

3/4"

9" 3" 3"

1' - 3"

FOURTH FLOOR

36' - 0"

M

SPRAY FOAM INSUL.

CONT. AT PERIMETER

AND AT ALL GAPS IN

CONSTRUCTION. REFER

TO AIR BARRIER REQS

AND DETAILS

REFERENCE FINISH

SCHEDULE FOR WALL

BASE AND FLOOR FINISH.

5/8" GWB

EXTEND GWB TO

UNDERSIDE OF DECK

METAL

ANGLE -

REFER TO

STRUCTURAL

DWGS

3" (R-20) CLOSED

CELL SPRAY

FOAM

INSULATION

STANDARD FACE

BRICK

PROVIDE SILL SEAL UNDER

BOTTOM OF STUD TRACK

BENT PLATE, REFER TO

STRUCTURAL DWGS

MORTAR MESH

THRU WALL

FLASHING W/

WEEP @ 24" O.C.

SEALANT &

BACKER ROD

MIN 1/4" THICK

COMPRESSIBLE

MATERIAL

A-611

AIR SPACE

3" 3"

ROOF BRG.

48' - 0"

6"

12"

SSMR

VAPOR PERMEABLE ROOF UNDERLAYMENT

5/8" GYPSUM SHEATHING

1 1/2" METAL ROOF DECK

R-50 BATT INSULATION

CFMF ROOF TRUSS

BRICK SOLDER COURSE

STEEL LINTEL

HSS 6X6 @ ROOF BRG.

REF STRUCTURAL

PERFORATED METAL

PANEL SOFFIT ON 2 1/2"

CFMF @ 12" O.C.

PRE-FINISHED CLOSURE

TRIM WITH CONT.

SEALANT

STANDARD FACE BRICK

MASONRY TIES

MORTAR MESH

THRU WALL FLASHING

WITH WEEP HOLE @ 24"

O.C.

THIRD FLOOR

24' - 0"

3" (R-20) CLOSED

CELL SPRAY FOAM

INSULATION

CONCRETE SLAB

ON METAL DECK

FLOOR SYSTEM

SPRAY FOAM INSUL.

CONT. AT PERIMETER

AND AT ALL GAPS IN

CONSTRUCTION.

REFER TO AIR BARRIER

REQS AND DETAILS

EXTEND GWB TO

UNDERSIDE OF DECK

5/8" GYPSUM

SHEATHING

A-331

A-331

SIM.

9" 3" 3" 1' - 3"

BENT PLATE - REFER

TO STRUCTURAL

DWGS

MIN 1/4" THICK

COMPRESSIBLE

MATERIAL

SEALANT &

BACKER ROD

MANUFACTURE

D LIPPED BRICK

SHELF ANGLE - REFER

TO STRUCTURAL DWGS

THRU WALL

FLASHING WEEP @

24" OC

MORTAR MESH

TYP. @ 3RD - 4TH

FLOOR

9" 3" 3"

1' - 3"

BITUMINOUS ROOFING

PER SPECS.

R-36

POLYISOCYANURATE

ROOF INSULATION TYP.

EXTEND ROOFING UP BACKSIDE OF

PARAPET PER ROOFING DETAILS.

FASTEN PRE-FORMED METAL SCUPPER

PER MFR.

SHINGLE FLEXIBLE FLASHING OVER

METAL DRIP FLASHING

FASTEN PRE-FINISHED METAL

SCUPPER TO PARAPET THRU

BLOCKING, CONCEAL FASTENERS

WITH DRIP FLASHING

WRAP OPENING WITH

FLEXIBLE FLASHING, ALL

AROUND

PRE-FINISHED

METAL

CONDUCTOR

HEAD (SM-1)

6"X8" RECTANGULAR

DOWNSPOUT (SM-1)

SEALANT JOINT TYP.

6"

1" 8"

6"

FLASHING OVERLAPS SCUPPER

AND FASTENERS

ROOF FLASHING

AIR BARRIER

TRANSITION MEMBRANE

SHALL OVERLAP

ROOFING MEMBRANE OR

ROOF FLASHING

MINIMUM 3".

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S D

R

AW

N B

Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

'D

D

AT

E

TI

M

E

ST

AM

P:

IS

SU

E D

AT

E:

N

AO

F

IL

E N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

SO

LI

C

IT

AT

IO

N N

O

C O

N

TR

AC

T

N O

7/

/2

:0 7:

P

M

A-331

BCOF

N O

R

FO

LK

D

IS

TR

IC

T

N O

R

FO

LK

, V

A

S.

H

EN

D

R

IC

K

S.

H

EN

D

R

IC

K

D . G

EB

LE

R

D . G

EB

LE

R

FE

BR

U

AR

Y

R

TA

S U

BM

IT

TA

L

SE

CT

IO

N

DE

TA

IL

S

JB

LE

FO

R T

EU

ST

IS

, V

IR

G

IN

IA

AI

T

BA

R

R

AC

KS

C

O M

PL

EX

P H

AS

E

-B

C O

F

PN

SCALE: 1 1/2" = 1'-0"

A-311

1 SECTION DETAIL

SCALE: 1 1/2" = 1'-0"

A-311

2 TYP. WINDOW HEAD DETAIL

SCALE: 1 1/2" = 1'-0"

A-311

4 SECTION DETAIL

SCALE: 1 1/2" = 1'-0"

A-311

6 SECTION DETAIL

SCALE: 1 1/2" = 1'-0"

A-311

5 SECTION DETAIL

SCALE: 3" = 1'-0"3 TYP. SHELF ANGLE DETAIL

A-331

0'

SCALE: 1-1/2" = 1' - 0"

1' 2'

0'

SCALE: 3" = 1' - 0"

6' 12'SCALE: 3" = 1'-0"7 TYP. SCUPPER W/CONDUCTOR HEAD DETAIL

A-316

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

AM

E N D

M

EN

T #2

J

U L

Sheets
A-006 - AIR BARRIER DETAILS
A-331 - SECTION DETAILS
A-332 - SECTION DETAILS
A-423 - STAIR DETAILS
A-605 - DOOR DETAILS

File details come from the government source that posted it. Updated .