A0002 SHEET A402.pdf

PDF 180 KB Posted

Attached to
AIT Barracks Fort Eustis VA (Amendment 0004) Federal contract opportunity
Solicitation number
W9123620B0015
Issued by
Department of the Army Corps of Engineers Engineering District Norfolk

About this file

This document contains drawings and specifications for a construction project. The U.S. Army Corps of Engineers is soliciting proposals to construct AIT Barracks at Fort Eustis in Virginia. Drawings include floor plans, elevations, and details for typical 3PN rooms. Construction will be performed in accordance with the specifications and drawings provided. Proposals are due by contacting the contracting officers via email. The solicitation number is W9123620B0015 and amendments provide additional details for offerors.

View the file

Other files for this federal contract opportunity

Other files attached to AIT Barracks Fort Eustis VA (Amendment 0004), newest first.
File Type Posted
Amendment 4.pdf PDF
W9123620B0015 Amendment 0003.pdf PDF
A0002 SHEET A423.pdf PDF
A0002 SPEC 09 30 10.pdf PDF
A0002 SPEC 06 61 16.pdf PDF
A0002 SHEET I002.pdf PDF
A0002 SHEET F103.pdf PDF
A0002 SHEET A407.pdf PDF
A0002 SHEET A401.pdf PDF
W91236-20-B-0015 Amend 0002.pdf PDF
A0002 SPECS TOC.pdf PDF
A0002 Revised FFE Package.pdf PDF
A0002 SPEC 08 33 23.pdf PDF
A0002 SPEC 07 26 30.pdf PDF
A0002 SHEET F104.pdf PDF
A0002 SHEET A406.pdf PDF
A0002 SHEET A006.pdf PDF
A0002 SPEC 23 65 00.pdf PDF
A0002 SHEET A602.pdf PDF
A0002 SPEC 14 21 23.pdf PDF
A0002 SHEET A332.pdf PDF
A0002 SHEET LP501.pdf PDF
A0002 SHEET F102.pdf PDF
A0002 SHEET A403.pdf PDF
A0002 SPEC 23 81 47.pdf PDF
A0002 SHEET T114.pdf PDF
A0002 SHEET F101.pdf PDF
A0002 SPEC 12 31 00.pdf PDF
A0001 SHEET C516.pdf PDF
A0001 SHEET A401.pdf PDF
A0001 SPEC 28 31 76.pdf PDF
A0001 SHEET EG501.pdf PDF
A0001 SHEET A602.pdf PDF
A0001 SHEET LP501.pdf PDF
A0001 SHEET A406.pdf PDF
A0001 SPEC 07 61 1400 20.pdf PDF
A0001 SHEET A611.pdf PDF
A0001 SHEET A407.pdf PDF
A0001 SHEET A403.pdf PDF
A0001 SHEET A202.pdf PDF
A0001 SHEET A405.pdf PDF
A0001 SHEET A402.pdf PDF
A0001 SHEET A114.pdf PDF
A0001 SHEET A121 THRU A151.pdf PDF
A0001 SHEET A601.pdf PDF
Amendment 1.pdf PDF
A0001 SHEET I002 AND I221.pdf PDF
H.01.01 794_AIT_PH4_SID_RTA_SUBMITTAL.pdf PDF
H.01.01 794_AIT_PH4_SPEC_RTA_SUBMITTAL.pdf PDF
H.01.01 794_AIT_PH4_FFE_RTA_SUBMITTAL.pdf PDF
Show all 50

AIT Barracks Fort Eustis VA (Amendment 0004) has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

OS1 OS1

F

J

H

J.2

A-402 46

A-406 6

3PN

3PN

LAV

1045A

LAV

1043A

CLO

1043B

CLO

1043C

CLO

1043D

CLO

1045D

CLO

1045C

CLO

1045B

1043D1045D

1045C 1043C

1043B1045B

1043A

1045A

MECH CLO

1112F

F

3' - 1 3/4" 2' - 4 1/4" 4' - 2" 2' - 4" 6" 2' - 8" 4' - 2" 2' - 0 1/4" 3' - 1 3/4"

3'

0" 3'

0"

3'

0"

3'

6"

12' - 0" 12' - 0"

S6B

S6B

S6B

S6B

S6BS6B

S4B

S4

S4

S4

S4A

S4A S4A

F6A

F4A

S4

S4

S4

S4

S4A

S4A

S4A

F6A

F4A

S4

S6

F4A

S6

F4A

S6B

A-502

TYP

A-408

G

F

J

H

J.2

A.F.F.

GWB

9' - 0" A.F.F.

GWB

9' - 0"

A.F.F.

GWB

9' - 0" A.F.F.

GWB

9' - 0"

A.F.F.

GWB

8' - 0"A.F.F.

GWB

8' - 0"

A.F.F.

GWB

9' - 0"

A.F.F.

GWB

9' - 0"

A.F.F.

GWB

9' - 0" A.F.F.

GWB

9' - 0"

A.F.F.

GWB

9' - 0"

A.F.F.

GWB

9' - 0"

OPEN TO ABOVE

G

3PN

3PN

2 TYP

8 TYP

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S D

R

AW

N B

Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

'D

D

AT

E

TI

M

E

ST

AM

P:

IS

SU

E D

AT

E:

N

AO

F

IL

E N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

SO

LI

C

IT

AT

IO

N N

O

C O

N

TR

AC

T

N O

7/

/2

1:

:4

PM

A-402

BCOF

N O

R

FO

LK

D

IS

TR

IC

T

N O

R

FO

LK

, V

A

S.

H

EN

D

R

IC

K

S.

H

EN

D

R

IC

K

D . G

EB

LE

R

D . G

EB

LE

R

FE

BR

U

AR

Y

R

TA

S U

BM

IT

TA

L

EN

LA

RG

ED

D

RA

W

IN

G S

-3

PN

R O

O M

S

JB

LE

FO

R T

EU

ST

IS

, V

IR

G

IN

IA

AI

T

BA

R

R

AC

KS

C

O M

PL

EX

P H

AS

E

-B

C O

F

PN

SCALE: 3/8" = 1'-0"

A-111

1 ENLARGED FLOOR PLAN - TYPICAL 3PN ROOM

SCALE: 3/8" = 1'-0"2 ENLARGED RCP - TYPICAL 3PN ROOM

SCALE: 1/4" = 1'-0"

A-402

3 3PN - NORTH ELEVATION

SCALE: 1/4" = 1'-0"

A-402

4 3PN - EAST ELEVATION

SCALE: 1/4" = 1'-0"

A-402

5 3PN - SOUTH ELEVATION

SCALE: 1/4" = 1'-0"

A-402

6 3PN - WEST ELEVATION

NOTE: REFER TO A-001 & A-161 FOR REFLECTED CEILING SYMBOLS.

0'

SCALE: 3/8" = 1' - 0"

2' 4' 6' 8'

4'0' 8' 12'

SCALE: 1/4" = 1' - 0"

NOTE: REFER TO TOILET ACCESSORY SCHEDULE ON A-405 FOR KEY NOTES.

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

AM

E N D

M

EN

T #1

J

U L

NOTE:

1. REFER TO TOILET ACCESSORY SCHEDULE ON A-405 FOR KEY NOTES

2. FOR TOILET ACCESSORY LOCATIONS, REFER TO 7/A-401

Sheets
A-402 - ENLARGED DRAWINGS - 3PN ROOMS

File details come from the government source that posted it. Updated .