CLIN 002_Elect RFI_2024.0529.pdf

PDF 855 KB Posted

Attached to
BLDG 32 Renovation Natick Massachusetts
Solicitation number
W911QY24R0005
Issued by

About this file

This document appears to be a Reflected Ceiling Plan and Electrical Lighting Plan related to the renovation of Building 32 at the US Army Natick Soldier Systems Center in Natick, Massachusetts. The Solicitation Number is W911QY24R0005, and the requirement is 100% set-aside for small businesses.

The renovation project includes two contract line items (CLINs) - CLIN 0001 and CLIN 0002. Presently, funding is available for CLIN 0001 but not CLIN 0002. Offerors are asked to propose on both CLINs in case the Government obtains additional funding for CLIN 0002. The work involves providing all labor, materials, and equipment necessary to complete the renovation of Building 32, including electrical and lighting systems. Offerors will be required to attend a site visit. The contracting agency is the Department of the Army Materiel Command Army Contracting Command Aberdeen Proving Ground.

View the file

Other files

Show all 17

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1 62 3 4 5

D

A

B

C

E

'-0

EX

IS

TI

N G

'-0

EX

IS

TI

N G

'-0

EX

IS

TI

N G

'-0

EX

IS

TI

N G

16'-0"±

EXISTING

16'-0"±

EXISTING

16'-0"±

EXISTING

16'-0"±

EXISTING

16'-0"±

EXISTING

SD

SP

SP SP

SP

SP SP

SP SP

SPSP

SP

SP SP

SP SP

SP SP

SP SPSP SP

SP SPSPSP SPSP

SP SP SP

SPSP

SD SD

SDSD

SD

SD

SD

SD

SP

SP

SP SP

EF EF EF EF EF

SP

SPSP

SP

SPSP

SP

SPSP

SPSPSPSP

SPSPSPSP

E

E

E

KITCHEN

STAGE AREA

RESTROOM

BALL ROOM

CONF

ENTRY

LOBBY

ST-1

ST-2

EGRESS

LOBBY

CL CL CL

L2 L2

L2 L2

L2 L2

L2 L2

L2 L2 L2 L2 L2 L2 L2

L2

L2

L2

L2

L2L2

L2

L2L2L2

L2 L2 L2

L2 L2 L2 L2

L2

L2

L2

L2 L2

L1 L1

L1

L1 L1

L1

L1

L1L1

L1 L1

L1

ELECTRICAL GENERAL NOTES

1.

2.

3.

4.

ELECTRICAL CONTRACTOR SHALL BE

RESPONSIBLE FOR COORDINATING AND

CONFIRMING LOCATIONS AND MOUNTING

HEIGHTS OF ALL RELOCATED FIXTURES,

SWITCHES AND OTHER DEVICES WITH

ARCHITECT.

ALL EXIT SIGNS AND EMERGENCY BATTERY

BOXES SHALL BE UNSWITCHED AND

POWERED FROM CONSTANT POWER SOURCE.

ALL LIFE SAFETY DEVICES ARE SHOWN NEW

UNLESS NOTED WITH (E).

ALL LIGHTING INDICATED LIGHTING IS

RELOCATED FROM SALVAGED LIGHTS FROM

DEMOLITION PHASE.

E

REFLECTIVE CEILING PLAN LEGEND

EXISTING 2 X 2 RECESSED LIGHT

TO REMAIN

EXISTING LINEAR PENDENT LIGHT

TO REMAIN

LITHONIA 2BLT2 40L ADP EZ1 LP835

RECESSED LED LIGHT

LITHONIA LBR6 19 WATT DOWNLIGHT

LED EXIT SIGN LITHONIA #EXR LED EL 6,

WITH UNVERSAL MOUNTING, SEALED

MAINTENCE FREE NICKEL CADMIUM

BATTERY, HOUSING COLOR-WHITE,

DIRECTIONAL CHEVRON ARROW WHERE

INDICATED.

DUAL HEAD EMERGENCY BATTERY

BACKUP LITHONIA #EU2 LED M12

EXISTING / NEW HVAC SUPPLY

DIFFUSER. SEE MECHANICAL DRAWINGS

FOR MORE INFORMATION.

EXISTING / NEW HVAC RETURN

DIFFUSER. SEE MECHANICAL DRAWINGS

FOR MORE INFORMATION.

FIRE SPRINKLER HEAD. SEE FIRE

PROTECTION DRAWINGS FOR MORE

INFORMATION.

SMOKE DETECTOR. SEE FIRE ALARM

DRAWINGS FOR MORE INFORMATION.

ELECTRICAL LIGHTING KEY NOTES

ROOM 103 LIGHTING. ALL LIGHTING TO REMAIN

IN PLACE.

ROOM 107 LIGHTING. ALL LIGHTING TO REMAIN

IN PLACE.

L1

E

SP

SD

L2

E-103

SE

C

O N

D F

LO

O

R

EL

EC

T

LI

G

H

TI

N G

P

LA

N

1/4" = 1'-0"

1 SECOND FLOOR ELECTRICAL LIGHTING PLAN

E-103

A

B

C

D

D

ES

C R

IP

TI

O N

M

AR

K D

AT

E

SHEET ID

SO

LI

C

IT

AT

IO

N N

O

D

ES

IG

N

ED

B

Y:

SI

ZE

SU

BM

IT

TE

D B

Y:

C O

N

TR

AC

T

N O

AR

C

H D

C H

EC

KE

D B

Y:

D R

AW

N

B Y:

IS

SU

E D

AT

E:

PR

O

JE

C

T N

U M

BE

R

FI

LE

N

AM

E:

D R

W

D R

W

N O

V

El ec tri ca l S er ie s.

dw g

BU

IL

D

IN

G

IN

TE

R

IO

R

R

EN

O

VA

TI

O

N S

N

AT

IC

K

SY

ST

EM

S

O

LD

IE

R

C

EN

TE

R

N

AT

IC

K, M

AS

SA

C

H U

SE

TT

S

U .S

. A R

M Y

N A

TI

C

K

SO

LD

IE

R S

YS

TE

M S

C

EN

TE

R

D

IR

EC

TO

R A

TE

O

F

PU

B

LI

C W

O R

K S

G

EN

ER

A

L G

R

EE

N E

A

VE

N U

E N

A

TI

C K

, M A

TB

D

D R

W

TB

D

TB

D

FI

N

AL

C

O N

ST

R

U C

TI

O

N D

O C

U M

EN

TS

N

O V

D R

W

FI

N

AL

C O

N

ST

R U

C

TI

O N

D O

C U

M

EN

TS

C

LI

N B

R

EA

KD

O

W N

D

EC

EL

EC

TR

IC

AL

R

FI

G

O

VE

R N

M

EN

T R

ES

PO

N

SE

M

AY

Sheets and Views
E-103 Elect Light 2nd Pln

File details come from the government source that posted it. Updated .