CLIN 002_Elect RFI_2024.0529.pdf
PDF 855 KB Posted
- Attached to
- BLDG 32 Renovation Natick Massachusetts
- Solicitation number
- W911QY24R0005
About this file
This document appears to be a Reflected Ceiling Plan and Electrical Lighting Plan related to the renovation of Building 32 at the US Army Natick Soldier Systems Center in Natick, Massachusetts. The Solicitation Number is W911QY24R0005, and the requirement is 100% set-aside for small businesses.
The renovation project includes two contract line items (CLINs) - CLIN 0001 and CLIN 0002. Presently, funding is available for CLIN 0001 but not CLIN 0002. Offerors are asked to propose on both CLINs in case the Government obtains additional funding for CLIN 0002. The work involves providing all labor, materials, and equipment necessary to complete the renovation of Building 32, including electrical and lighting systems. Offerors will be required to attend a site visit. The contracting agency is the Department of the Army Materiel Command Army Contracting Command Aberdeen Proving Ground.
View the file
Other files
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1 62 3 4 5
D
A
B
C
E
'-0
EX
IS
TI
N G
'-0
EX
IS
TI
N G
'-0
EX
IS
TI
N G
'-0
EX
IS
TI
N G
16'-0"±
EXISTING
16'-0"±
EXISTING
16'-0"±
EXISTING
16'-0"±
EXISTING
16'-0"±
EXISTING
SD
SP
SP SP
SP
SP SP
SP SP
SPSP
SP
SP SP
SP SP
SP SP
SP SPSP SP
SP SPSPSP SPSP
SP SP SP
SPSP
SD SD
SDSD
SD
SD
SD
SD
SP
SP
SP SP
EF EF EF EF EF
SP
SPSP
SP
SPSP
SP
SPSP
SPSPSPSP
SPSPSPSP
E
E
E
KITCHEN
STAGE AREA
RESTROOM
BALL ROOM
CONF
ENTRY
LOBBY
ST-1
ST-2
EGRESS
LOBBY
CL CL CL
L2 L2
L2 L2
L2 L2
L2 L2
L2 L2 L2 L2 L2 L2 L2
L2
L2
L2
L2
L2L2
L2
L2L2L2
L2 L2 L2
L2 L2 L2 L2
L2
L2
L2
L2 L2
L1 L1
L1
L1 L1
L1
L1
L1L1
L1 L1
L1
ELECTRICAL GENERAL NOTES
1.
2.
3.
4.
ELECTRICAL CONTRACTOR SHALL BE
RESPONSIBLE FOR COORDINATING AND
CONFIRMING LOCATIONS AND MOUNTING
HEIGHTS OF ALL RELOCATED FIXTURES,
SWITCHES AND OTHER DEVICES WITH
ARCHITECT.
ALL EXIT SIGNS AND EMERGENCY BATTERY
BOXES SHALL BE UNSWITCHED AND
POWERED FROM CONSTANT POWER SOURCE.
ALL LIFE SAFETY DEVICES ARE SHOWN NEW
UNLESS NOTED WITH (E).
ALL LIGHTING INDICATED LIGHTING IS
RELOCATED FROM SALVAGED LIGHTS FROM
DEMOLITION PHASE.
E
REFLECTIVE CEILING PLAN LEGEND
EXISTING 2 X 2 RECESSED LIGHT
TO REMAIN
EXISTING LINEAR PENDENT LIGHT
TO REMAIN
LITHONIA 2BLT2 40L ADP EZ1 LP835
RECESSED LED LIGHT
LITHONIA LBR6 19 WATT DOWNLIGHT
LED EXIT SIGN LITHONIA #EXR LED EL 6,
WITH UNVERSAL MOUNTING, SEALED
MAINTENCE FREE NICKEL CADMIUM
BATTERY, HOUSING COLOR-WHITE,
DIRECTIONAL CHEVRON ARROW WHERE
INDICATED.
DUAL HEAD EMERGENCY BATTERY
BACKUP LITHONIA #EU2 LED M12
EXISTING / NEW HVAC SUPPLY
DIFFUSER. SEE MECHANICAL DRAWINGS
FOR MORE INFORMATION.
EXISTING / NEW HVAC RETURN
DIFFUSER. SEE MECHANICAL DRAWINGS
FOR MORE INFORMATION.
FIRE SPRINKLER HEAD. SEE FIRE
PROTECTION DRAWINGS FOR MORE
INFORMATION.
SMOKE DETECTOR. SEE FIRE ALARM
DRAWINGS FOR MORE INFORMATION.
ELECTRICAL LIGHTING KEY NOTES
ROOM 103 LIGHTING. ALL LIGHTING TO REMAIN
IN PLACE.
ROOM 107 LIGHTING. ALL LIGHTING TO REMAIN
IN PLACE.
L1
E
SP
SD
L2
E-103
SE
C
O N
D F
LO
O
R
EL
EC
T
LI
G
H
TI
N G
P
LA
N
1/4" = 1'-0"
1 SECOND FLOOR ELECTRICAL LIGHTING PLAN
E-103
A
B
C
D
D
ES
C R
IP
TI
O N
M
AR
K D
AT
E
SHEET ID
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
SI
ZE
SU
BM
IT
TE
D B
Y:
C O
N
TR
AC
T
N O
AR
C
H D
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
PR
O
JE
C
T N
U M
BE
R
FI
LE
N
AM
E:
D R
W
D R
W
N O
V
El ec tri ca l S er ie s.
dw g
BU
IL
D
IN
G
IN
TE
R
IO
R
R
EN
O
VA
TI
O
N S
N
AT
IC
K
SY
ST
EM
S
O
LD
IE
R
C
EN
TE
R
N
AT
IC
K, M
AS
SA
C
H U
SE
TT
S
U .S
. A R
M Y
N A
TI
C
K
SO
LD
IE
R S
YS
TE
M S
C
EN
TE
R
D
IR
EC
TO
R A
TE
O
F
PU
B
LI
C W
O R
K S
G
EN
ER
A
L G
R
EE
N E
A
VE
N U
E N
A
TI
C K
, M A
TB
D
D R
W
TB
D
TB
D
FI
N
AL
C
O N
ST
R
U C
TI
O
N D
O C
U M
EN
TS
N
O V
D R
W
FI
N
AL
C O
N
ST
R U
C
TI
O N
D O
C U
M
EN
TS
C
LI
N B
R
EA
KD
O
W N
D
EC
EL
EC
TR
IC
AL
R
FI
G
O
VE
R N
M
EN
T R
ES
PO
N
SE
M
AY
| Sheets and Views |
| E-103 Elect Light 2nd Pln |
File details come from the government source that posted it. Updated .