Base Pricing
| Base Pricing | | | |
| | INSTRUCTIONS: This pricing is for the North/South Cantonment comprises the physical area of Aberdeen Proving Ground and the Former Edgewood arsenal area. The Churchville Automotive test facility, Grace’s quarters and Carrol Island areas all fall with the region which is included in the Davis Bacon wage determinations for Aberdeen/Edgewood Areas. Please include the base unit price in column E and it will automatically calculate the total price in column F. Add the percentage escalation in the Pricing Summary tab only. | INSTRUCTIONS: This pricing is for the Adelphi Laboratory Center area as it falls within a different zone relative to the Davis Bacon wage determinations. Please include the co-efficient in cel H9 as a number (i.e., 1.21; 0.97; etc.) and it will automatically calculate the unit price in column H and the total price in column I. |
| 0000 | SUBCLINS 0001-0036 | | |
| SF/IN=Square Foot Per Inch Of Thickness | | | | | | | |
| VLF = Vertical Linear Feet | | | | | | | |
| ITEM NO. | SUPPLIES/SERVICES | UNIT | ESTIMATED 5 YEARS QUANTITY | UNIT PRICE WITHOUT ESCALATION | TOTAL | ESTIMATED QUANTITY FOR ALC | ALC COEFFICIENT | ALC TOTAL |
| | | | 0 |
| 0001 | ASBESTOS ROOFING | CLIN 0001 - APG NORTH AND SOUTH | CLIN 0002 - ALC | |
| 0001AA | REMOVE AND DISPOSE OF NON-FRIABLE | SF | 25000 | $ - 0 | $0.00 | 5,000 | $ - 0 | $ - 0 |
| ASBESTOS SHINGLE ROOFING AND FELTS | | | | | | | |
| (ONE LAYER OF SHINGLES) | | | | | | | |
| 0001AB | REMOVE AND DISPOSE OF NON-FRIABLE | SF | 20000 | $ - 0 | $0.00 | 5,000 | $ - 0 | $ - 0 |
| ASBESTOS ROLL ROOFING | | | | | | | |
| 0001AC | REMOVE AND DISPOSE OF NON-FRIABLE | SF | 40000 | $ - 0 | $0.00 | 5,000 | $ - 0 | $ - 0 |
| ASBESTOS CONTAINING BASE FLASHING/CURB | | | | | | | |
| FLASHING | | | | | | | |
| 0001AD | REMOVE AND DISPOSE OF FRIABLE OR | SF | 125000 | $ - 0 | $0.00 | 5,000 | $ - 0 | $ - 0 |
| NON-FRIABLE ASBESTOS CORRUGATED | | | | | | | |
| FIBER REINFORCED CEMENT ROOF PANELS | | | | | | | |
| 0001AE | TRANSITE REMOVAL (WALLS, CEILINGS, | SF | 10000 | $ - 0 | $0.00 | 2,000 | $ - 0 | $ - 0 |
| SOFFITS) COMPLY WITH ALL FEDERAL AND | | | | | | | |
| STATE REGULATIONS >0' UP TO 10' | | | | | | | |
| 0001AF | TRANSITE REMOVAL (WALLS, CEILINGS, | SF | 10000 | $ - 0 | $0.00 | 2,000 | $ - 0 | $ - 0 |
| SOFFITS) COMPLY WITH ALL FEDERAL AND | | | | | | | |
| STATE REGULATIONS >10' UP TO 20' | | | | | | | |
0002 ASPHALT ROOFING
| 0002AA | REMOVE AND DISPOSE OF ASPHALT | SF | 250000 | $ - 0 | $0.00 | 75,000 | $ - 0 | $ - 0 |
| SHINGLE ROOFING AND FELT UNDERLAYMENT | | | | | | | |
| (ONE LAYER OF SHINGLES) | | | | | | | |
0002AB REPLACE INDIVIDUAL ASPHALT SHINGLE EA 1500 $ - 0 $0.00 500 $ - 0 $ - 0
| 0002AC | RENAIL SHEATHING AND INSTALL | SF | 125000 | $ - 0 | $0.00 | 20,000 | $ - 0 | $ - 0 |
| ASPHALT SHINGLE ROOFING, 30 LB FELT | | | | | | | |
| AND 25 YEAR ASPHALT SHINGLES ON ALL | | | | | | | |
| SLOPES | | | | | | | |
| 0002AD | RENAIL SHEATHING AND INSTALL | SF | 250000 | $ - 0 | $0.00 | 75,000 | $ - 0 | $ - 0 |
| ASPHALT SHINGLE ROOFING, 30 LB FELT | | | | | | | |
| AND 40 YEAR ASPHALT SHINGLES ON ALL | | | | | | | |
| SLOPES | | | | | | | |
| 0002AE | INSTALL AN ADDITIONAL PLY OF THIRTY POUND | SF | 250000 | $ - 0 | $0.00 | 75,000 | $ - 0 | $ - 0 |
| ROOFING FELT, ALL SLOPES | | | | | | | |
| 0002AF | INSTALL A SINGLE LAYER OF SYNTHETIC FIBER | SF | 100000 | $ - 0 | $0.00 | 50,000 | $ - 0 | $ - 0 |
| ROOFING FELT, ALL SLOPES | | | | | | | |
| 0002AG | INSTALL AN ADDITIONAL LAYER OF SYNTHETIC | SF | 25000 | $ - 0 | $0.00 | 15,000 | $ - 0 | $ - 0 |
| FIBER ROOFING FELT, ALL SLOPES | | | | | | | |
| 0002AH | REMOVE AND DISPOSE OF ASPHALT | SF | 12500 | $ - 0 | $0.00 | 1,000 | $ - 0 | $ - 0 |
| ROLL ROOFING AND UNDERLAYMENTS | | | | | | | |
| 0002AI | RENAIL SHEATHING AND INSTALL DOUBLE | SF | 12500 | $ - 0 | $0.00 | 1,000 | $ - 0 | $ - 0 |
| COVERAGE ASPHALT ROLL ROOFING | | | | | | | |
| AND UNDERLAYMENTS | | | | | | | |
0003 BUILT UP AND IRMA ROOF SYSTEMS
| 0003AA | REMOVE AND DISPOSE OF LIGHT WEIGHT | SF/IN | 37500 | $ - 0 | $0.00 | 20,000 | $ - 0 | $ - 0 |
| GYPSUM MATERIAL | | | | | | | |
| 0003AB | REMOVE AND DISPOSE OF BUILT UP | SF | 500000 | $ - 0 | $0.00 | 100,000 | $ - 0 | $ - 0 |
| ROOFING, ASPHALT | | | | | | | |
| 0003AC | REMOVE AND DISPOSE OF BUILT UP | SF | 500000 | $ - 0 | $0.00 | 50,000 | $ - 0 | $ - 0 |
| ROOFING, COAL TAR | | | | | | | |
| 0003AD | REMOVE AND SALVAGE GRAVEL BALLAST, APPLY | SF | 500000 | $ - 0 | $0.00 | 1,000 | $ - 0 | $ - 0 |
| FLOOD COAT OF HOT ASPHALT TO ROOF | | | | | | | |
| SURFACE, COVER WITH SALVAGED GRAVEL | | | | | | | |
| 0003AE | REMOVE AND DISPOSE OF GRAVEL BALLAST | SF | 500000 | $ - 0 | $0.00 | 1,000 | $ - 0 | $ - 0 |
| APPLY FLOOD COAT OF HOT ASPHALT TO ROOF | | | | | | | |
| SURFACE, COVER WITH NEW GRAVEL | | | | | | | |
| 0003AF | REMOVE GRAVEL, APPLY FLOOD COAT OF HOT | SF | 500000 | $ - 0 | $0.00 | 1,000 | $ - 0 | $ - 0 |
| ASPHALT AND NEW PLY OF ROOFING MEMBRANE | | | | | | | |
| SET IN HOT ASPHALT, COVER WITH GRAVEL | | | | | | | |
| BALLAST | | | | | | | |
| 0003AG | REMOVE, SALVAGE AND REINSTALL ROCK | SF | 250000 | $ - 0 | $0.00 | 1,000 | $ - 0 | $ - 0 |
| BALLAST FROM ROOF SURFACE | | | | | | | |
| 0003AH | REMOVE, SALVAGE AND REINSTALL EXISTING | SF | 250000 | $ - 0 | $0.00 | 1,000 | $ - 0 | $ - 0 |
| EPS BOARD INSULATION MATERIALS | | | | | | | |
| 0003AI | REMOVE AND DISPOSE OF THE EXISTING ROOF | SF | 250000 | $ - 0 | $0.00 | 1,000 | $ - 0 | $ - 0 |
| MEMBRANE AND PROTECTION MAT FROM | | | | | | | |
| CONCRETE ROOF DECK | | | | | | | |
| 0003AJ | REMOVE AND DISPOSE OF THE EXISTING ROOF | SF | 250000 | $ - 0 | $0.00 | 1,000 | $ - 0 | $ - 0 |
| MEMBRANE, PROTECTION MAT AND GYPSUM | | | | | | | |
| BOARD FROM STEEL ROOF DECK | | | | | | | |
| 0003AK | INSTALL NEW RUBBERIZED ASPHALT ROOFING | SF | 250000 | $ - 0 | $0.00 | 1,000 | $ - 0 | $ - 0 |
| SYSTEM AND PROTECTION MAT USING | | | | | | | |
| MATERIALS COMPATIBLE WITH EXISTING ROOF | | | | | | | |
| SYSTEM | | | | | | | |
| 0003AL | INSTALL NEW 1/2 INCH THICK CEMENT BOARD | SF | 250000 | $ - 0 | $0.00 | 1,000 | $ - 0 | $ - 0 |
| TO STEEL ROOFING DECK | | | | | | | |
| 0003AM | INSTALL NEW COLD APPLIED SBS MEMBRANE | SF | 250000 | $ - 0 | $0.00 | 1,000 | $ - 0 | $ - 0 |
| PROTECTION COURSE OVER ROOF MEMBRANE | | | | | | | |
| 0003AN | INSTALL NEW DRAINAGE MAT AND GEOTEXTILE | SF | 250000 | $ - 0 | $0.00 | 1,000 | $ - 0 | $ - 0 |
| FABRIC | | | | | | | |
0004 MODIFIED BITUMEN
| 0004AA | REMOVE AND DISPOSE OF BUILT UP | SF | 1250000 | $ - 0 | $0.00 | 375,000 | $ - 0 | $ - 0 |
| ROOFING, MODIFIED BITUMEN | | | | | | | |
| 0004AB | INSTALL 150 MIL., SBS BASE AND SBS CAP | SF | 225000 | $ - 0 | $0.00 | 100,000 | $ - 0 | $ - 0 |
| FULLY ADHERED WITH TORCH WELDING | | | | | | | |
| MODIFIED BITUMEN ROOFING SYSTEM, | | | | | | | |
| FOR FIFTEEN YEAR WARRANTY, IN | | | | | | | |
| ACCORDANCE WITH MFG'S RECOMMEND- | | | | | | | |
| ATION | | | | | | | |
| 0004AC | INSTALL FULLY ADHERED TORCH APPLIED | SF | 1250000 | $ - 0 | $0.00 | 375,000 | $ - 0 | $ - 0 |
| APP 180 MIL BASE AND GRANULAR COATED | | | | | | | |
| CAP SHEET WITH A FIFTEEN YEAR | | | | | | | |
| WARRANTY, IN ACCORDANCE WITH THE | | | | | | | |
| MANUFACTURER'S RECOMMENDATION | | | | | | | |
| 0004AD | INSTALL A FULLY ADHERED, COLD APPLIED | SF | 125000 | $ - 0 | $0.00 | 75,000 | $ - 0 | $ - 0 |
| SBS 150 MOD. BIT. ROOFING SYSTEM | | | | | | | |
| CONSISTING OF AN SBS 150 BASE AND CAP | | | | | | | |
| SHEET IN ACCORDANCE WITH THE | | | | | | | |
| MANUFACTURER'S REQUIRMENTS | | | | | | | |
| 0004AE | INSTALL A FULLY ADHERED, COLD APPLIED | SF | 1250000 | $ - 0 | $0.00 | 375,000 | $ - 0 | $ - 0 |
| APP180 MOD. BIT. ROOFING SYSTEM | | | | | | | |
| CONSISTING OF AN APP 180 BASE AND CAP | | | | | | | |
| SHEET IN ACCORDANCE WITH THE | | | | | | | |
| MANUFACTURER'S REQUIREMENTS | | | | | | | |
0004AF INSTALL AN SBS 150 INTERPLY SHEET SF 130000 $ - 0 $0.00 50,000 $ - 0 $ - 0
0004AG INSTALL AN APP 180 INTERPLY SHEET SF 220000 $ - 0 $0.00 75,000 $ - 0 $ - 0
| 0004AH | INSTALL A WHITE BUTYL ELASTOMERIC | SF | 1000000 | $ - 0 | $0.00 | 15,000 | $ - 0 | $ - 0 |
| ROOF COATING FORMULATED FOR USE ON MOD | | | | | | | |
| BIT ROOFS SYSTEMS PER MANUFACTURERS | | | | | | | |
| INSTALLATION AND TEN YEAR WARRANTY | | | | | | | |
| REQUIREMENTS | | | | | | | |
| 0004AJ | INSTALL ASPHALT BASE, FIBERED | SF | 625000 | $ - 0 | $0.00 | 20,000 | $ - 0 | $ - 0 |
| ALUMINUM COATING | | | | | | | |
0004AK REPAIR MODIFIED BITUMEN SEAMS LF 25000 $ - 0 $0.00 5,000 $ - 0 $ - 0
0004AL PATCH MODIFIED BITUMEN ROOFING SF 25000 $ - 0 $0.00 5,000 $ - 0 $ - 0
| 0004AM | INSTALL MODIFIED BITUMEN BASE | SF | 150000 | $ - 0 | $0.00 | 25,000 | $ - 0 | $ - 0 |
| FLASHING | | | | | | | |
| 0004AN | INSTALL MODIFIED BITUMEN CURB | SF | 150000 | $ - 0 | $0.00 | 25,000 | $ - 0 | $ - 0 |
| FLASHING | | | | | | | |
0004AP INSTALL PITCH POCKET->0 UP TO 50 SQ IN EA 100 $ - 0 $0.00 25 $ - 0 $ - 0
0004AQ INSTALL PITCH POCKET->50 UP TO 300 SQ IN EA 1375 $ - 0 $0.00 675 $ - 0 $ - 0
0005 METAL ROOFING AND WALL PANELS
0005AA REMOVE AND DISPOSE OF METAL ROOFING SF 125000 $ - 0 $0.00 45,000 $ - 0 $ - 0
0005AB INSTALL COPPER SHEET ROOFING SF 6000 $ - 0 $0.00 0 $ - 0 $ - 0
| 0005AC | INSTALL PLAIN PANEL METAL (STEEL) | SF | 1000 | $ - 0 | $0.00 | 1,000 | $ - 0 | $ - 0 |
| ROOFING | | | | | | | |
| 0005AD | INSTALL PLAIN PANEL METAL (ALUMINUM) | SF | 1000 | $ - 0 | $0.00 | 1,000 | $ - 0 | $ - 0 |
| ROOFING | | | | | | | |
| 0005AE | INSTALL FACTORY FINISHED PANEL | SF | 125000 | $ - 0 | $0.00 | 25,000 | $ - 0 | $ - 0 |
| METAL (STEEL) ROOFING STANDARD | | | | | | | |
| COLORS | | | | | | | |
| 0005AF | INSTALL FACTORY FINISHED PANEL | SF | 125000 | $ - 0 | $0.00 | 25,000 | $ - 0 | $ - 0 |
| METAL (ALUMINUM) ROOFING STANDARD | | | | | | | |
| COLORS | | | | | | | |
| 0005AG | INSTALL FACTORY FINSHED METAL WALL | SF | 125000 | $ - 0 | $0.00 | 25,000 | $ - 0 | $ - 0 |
| PANEL (STEEL) STANDARD MANUFACTURER | | | | | | | |
| COLORS, NON-INSULATED PANEL | | | | | | | |
| 0005AH | INSTALL FACTORY FINISHED METAL WALL | SF | 125000 | $ - 0 | $0.00 | 25,000 | $ - 0 | $ - 0 |
| PANEL (ALUMINUM) STANDARD MANUFACTURER | | | | | | | |
| COLORS, NON-INSULATED PANEL | | | | | | | |
| 0005AI | INSTALL NEW METAL HAT CHANNEL, 1.25 | LF | 4250 | $ - 0 | $0.00 | 500 | $ - 0 | $ - 0 |
| INCHES DEEP | | | | | | | |
| 0005AJ | INSTALL NEW METAL HAT CHANNEL 1.5 | LF | 6250 | $ - 0 | $0.00 | 500 | $ - 0 | $ - 0 |
| INCHES DEEP | | | | | | | |
| 0005AK | INSTALL NEW TRANSULCENT POLYCARBONATE | SF | 100000 | $ - 0 | $0.00 | 0 | $ - 0 | $ - 0 |
| HONEYCOMB STYLE WALL PANELS IN ALUMINUM | | | | | | | |
| FRAME, 1.5 INCHES IN THICKNESS TO CLERESTORY | | | | | | | |
| (EXTECH SERIES 3440 OR APPROVED EQUIVALENT | | | | | | | |
0006 SLATE ROOFING
| 0006AA | REMOVE AND DISPOSE SLATE ROOFING | SF | 75000 | $ - 0 | $0.00 | 0 | $ - 0 | $ - 0 |
| AND FELT UNDERLAYMENT | | | | | | | |
| 0006AB | REPLACE INDIVIDUAL BROKEN SLATE | EA | 250 | $ - 0 | $0.00 | 0 | $ - 0 | $ - 0 |
| SHINGLES | | | | | | | |
| 0006AC | REPLACE INDIVIDUAL BROKEN SLATE | EA | 50 | $ - 0 | $0.00 | 0 | $ - 0 | $ - 0 |
| SHINGLES WITH GOVERNMENT SUPPLIED | | | | | | | |
| SLATE SHINGLES | | | | | | | |
| 0006AD | RENAIL SHEATHING, INSTALL 30 LB FELT, | SF | 10000 | $ - 0 | $0.00 | 0 | $ - 0 | $ - 0 |
| INSTALL MANUFACTURED SLATE (NON- | | | | | | | |
| ASBESTOS FIBER CEMENT) SHINGLES | | | | | | | |
| 0006AE | RENAIL SHEATHING AND INSTALL NATURAL | SF | 75000 | $ - 0 | $0.00 | 0 | $ - 0 | $ - 0 |
| SLATE ROOOFING AND 30 LB FELT | | | | | | | |
| 0007 | CORRUGATED FIBER REINFORCED |
| CEMENT ROOF DECKING (NON-ASBESTOS) |
| 0007AA | REMOVE AND DISPOSE OF INSTALLED | SF | 125000 | $ - 0 | $0.00 | 5,000 | $ - 0 | $ - 0 |
| CORRUGATED FIBER REINFORCED | | | | | | | |
| CEMENT ROOF DECKING > 2" thick | | | | | | | |
0008 SINGLE PLY ROOFING EPDM ROOFING
0008AA REMOVE EPDM ROOFING SF 525000 $ - 0 $0.00 75,000 $ - 0 $ - 0
| 0008AB | REMOVE AND DISPOSE OF CONCRETE PAVER | SF | 7000 | $ - 0 | $0.00 | 5,000 | $ - 0 | $ - 0 |
| BALLAST FROM EPDM ROOF SYSTEMS | | | | | | | |
| 0008AC | REMOVE AND DISPOSE OF RIVER ROCK BALLAST | SF | 7000 | $ - 0 | $0.00 | 5,000 | $ - 0 | $ - 0 |
| FROM LOOSE LAID, GRAVEL BALLASTED EPDM | | | | | | | |
| ROOF SYSTEMS | | | | | | | |
| 008AD | INSTALL FULLY ADHERED EPDM | SF | 7000 | $ - 0 | $0.00 | 5,000 | $ - 0 | $ - 0 |
| ROOFING SYSTEM, INCLUDING BASE AND | | | | | | | |
| STRIP FLASHING,FASTENERS AND ADHESIVE | | | | | | | |
| 0008AE | INSTALL EPDM ROOFING SYSTEM WITH | SF | 7000 | $ - 0 | $0.00 | 5,000 | $ - 0 | $ - 0 |
| CONCRETE ROOF PAVER BALLAST, BASE | | | | | | | |
| STRIP AND PERFORATED EDGE FLASHING | | | | | | | |
0008AF REPAIR EPDM SEAMS LF 7500 $ - 0 $0.00 750 $ - 0 $ - 0
0008AG PATCH EPDM ROOFING SF 200 $ - 0 $0.00 200 $ - 0 $ - 0
0009 ROOF COATING SYSTEMS
| 0009AA | INSTALL FLUID APPLIED ELASTOMERIC | SF | 150000 | $ - 0 | $0.00 | 75,000 | $ - 0 | $ - 0 |
| ROOFING PRIMER, COVERED WITH THREE | | | | | | | |
| (3) COATS ELASTOMERIC ACRYLIC ROOF | | | | | | | |
| COATING ON EPDM ROOF SYSTEMS TO INCLUDE | | | | | | | |
| COVERING SEAMS WITH REINFORCING FABRIC | | | | | | | |
| 0009AB | INSTALL "SEAL-O-FLEX" ELASTOMERIC | SF | 160000 | $ - 0 | $0.00 | 45,000 | $ - 0 | $ - 0 |
| WATERPROOFING SYSTEM CONSISTING OF | | | | | | | |
| THREE PART SYSTEM WITH CLOTH REINFORCING | | | | | | | |
| 0009AC | INSTALL A THREE PART HYBRID URETHANE/ | SF | 250000 | $ - 0 | $0.00 | 40,000 | $ - 0 | $ - 0 |
| ELASTOMERIC ROOF COATING SYSTEM TO | | | | | | | |
| INCLUDE FABRIC PLUS THREE COATS | | | | | | | |
| 0009AD | INSTALL A POLYMETHYLMETHACRYLATE | SF | 250000 | $ - 0 | $0.00 | 40,000 | $ - 0 | $ - 0 |
| (PMMA) ROOF COATING SYSTEM OVER A | | | | | | | |
| STRUCTURAL CONCRETE DECK CONSISTING OF | | | | | | | |
| THREE PARTS TO INCLUDE FABRIC | | | | | | | |
| 0009AE | INSTALL A POLYMETHYLMETHACRYLATE | SF | 250000 | $ - 0 | $0.00 | 40,000 | $ - 0 | $ - 0 |
| (PMMA) ROOF COATING SYSTEM OVER A LIGHT | | | | | | | |
| WEIGHT CONCRETE DECK CONSISTING OF A ONE | | | | | | | |
| INCH LAYER OF ROCK WOOL INSULATION WITH | | | | | | | |
| SBS MODIFIED BITUMEN COVER BOARD SET IN | | | | | | | |
| LOW RISE ADHESIVE FOLLOWED BY THE THREE | | | | | | | |
| PART SYSTEM INCLUSIVE OF FABRIC | | | | | | | |
| 0009AF | INSTALL PMMA FLASHING TO CURBS, ROOF | SF | 125000 | $ - 0 | $0.00 | 20,000 | $ - 0 | $ - 0 |
| PENETRATIONS AND PARAPET WALLS IAW | | | | | | | |
| MANUFACTURER'S REQUIREMENTS | | | | | | | |
0010 THERMOPOLYOLEFIN (TPO) ROOFING
0010AA REMOVE AND DISPOSE OF TPO ROOFING SYSTEM SF 75000 $ - 0 $0.00 15,000 $ - 0 $ - 0
| 0010AB | INSTALL A FULLY ADHERED, FLEECE BACKED | SF | 250000 | $ - 0 | $0.00 | 75,000 | $ - 0 | $ - 0 |
| POLYESTER SCRIM REINFORCED TPO MEMBRANE | | | | | | | |
| WITH A NOMINAL THICKNESS OF 060 INCHES | | | | | | | |
| (TPO THICKNESS) | | | | | | | |
| 1010AC | INSTALL HOOK AND LOOP (VELCRO FASTENED) | SF | 250000 | $ - 0 | $0.00 | 15,000 | $ - 0 | $ - 0 |
| FLEECE BACKED 115 MIL TPO ROOF SYSTEM | | | | | | | |
| (RapidLock Membrane and Insulation or approved | | | | | | | |
| Equivalent) | | | | | | | |
| 0010AC | INSTALL FULLY ADHERED FLEECE BACKED | SF | 60000 | $ - 0 | $0.00 | 15,000 | $ - 0 | $ - 0 |
| TPO FLASHING 0.060 INCH THICKNESS | | | | | | | |
| 0010AD | INSTALL TPO VENT PIPE FLASHING, UP TO 3 | EA | 125 | $ - 0 | $0.00 | 75 | $ - 0 | $ - 0 |
| INCHES IN DIAMETER | | | | | | | |
| 0010AE | INSTALL TPO VENT PIPE FLASHING, FROM 3.1 | EA | 225 | $ - 0 | $0.00 | 75 | $ - 0 | $ - 0 |
| INCHES IN DIAMTER AND LARGER | | | | | | | |
0010AF REPAIR TPO/PVC MEMBRANE SEAMS LF 26250 $ - 0 $0.00 6,250 $ - 0 $ - 0
0010AG PATCH TPO/PVC ROOFING SF 37500 $ - 0 $0.00 3,750 $ - 0 $ - 0
| 0010AH | INSTALL FULLY ADHERED 12 INCH WIDE | LF | 7500 | $ - 0 | $0.00 | 300 | $ - 0 | $ - 0 |
| PERIMETER WARNING TAPE TEN FEET FROM | | | | | | | |
| ROOF EDGE | | | | | | | |
0011 ROOF WALKS
| 0011AA | INSTALL COMPOSITION TYPE TRAFFIC | SF | 5000 | $ - 0 | $0.00 | 50 | $ - 0 | $ - 0 |
| SURFACE (MINERAL SURFACE ASPHALT | | | | | | | |
| PLANK) FOR BUILT UP ROOFS | | | | | | | |
| 0011AB | INSTALL ADDITIONAL PLY OF TORCHED | SF | 11000 | $ - 0 | $0.00 | 3,300 | $ - 0 | $ - 0 |
| APPLIED MODIFIED BITUMEN CAP SHEET | | | | | | | |
| WITH CONTRASTING GRANULAR COATING | | | | | | | |
| TO MODIFIED BITUMEN ROOFING SYSTEM | | | | | | | |
| 0011AC | INSTALL ADDITIONAL PLY OF COLD APPLIED | SF | 11000 | $ - 0 | $0.00 | 3,300 | $ - 0 | $ - 0 |
| MODIFIED BITUMEN CAP SHEET WITH | | | | | | | |
| CONTRASTING GRANULAR COATING TO | | | | | | | |
| MODIFIED BITUMEN ROOFING SYSTEM | | | | | | | |
| 0011AD | INSTALL FULLY ADHERED, TPO COMPATIBLE | SF | 17500 | $ - 0 | $0.00 | 5,000 | $ - 0 | $ - 0 |
| FLEXIBLE WALK PATH WITH EMBOSSED | | | | | | | |
| DIAMOND PLATE TREAD DESIGN OF A | | | | | | | |
| CONTRASTING COLOR AND HIGH VISIBILITY | | | | | | | |
| EDGES ON TPO ROOF SYSTEMS | | | | | | | |
| 0012 | ROOF INSULATION / SHEETS, VENTING |
| NONVENTING BASE SHEETS |
0012AA REMOVE AND DISPOSE OF ROOF INSULATION SF/IN 2500000 $ - 0 $0.00 425,000 $ - 0 $ - 0
| 0012AB | INSTALL FLAT STOCK RIGID INSULATION | SF/IN | 2100000 | $ - 0 | $0.00 | 425,000 | $ - 0 | $ - 0 |
| BOARD, POLYISOCYANURATE FOAM | | | | | | | |
| 0012AC | INSTALL TAPER STOCK INSULATION TO | SF/IN | 625000 | $ - 0 | $0.00 | 62,500 | $ - 0 | $ - 0 |
| SPECIFIED TAPER | | | | | | | |
| 0012AD | INSTALL EXPANDED POLYSTYRENE BOARD (EPS) | SF/IN | 250000 | $ - 0 | $0.00 | 50,000 | $ - 0 | $ - 0 |
| INSULATION (Dow Blu-Board or equivalent) | | | | | | | |
| 0012AE | INSTALL MODIFIED BITUMEN ASPHALT FACED | SF/IN | 125000 | $ - 0 | $0.00 | 25,000 | $ - 0 | $ - 0 |
| ROCK WOOL INSULATION BOARD (SMART BOARD) | | | | | | | |
| 0012AF | INSTALL RIGID POLYISOCYANURATE COVER | SF | 125000 | $ - 0 | $0.00 | 25,000 | $ - 0 | $ - 0 |
| BOARD, 1/2 INCH THICKNESS (SecurShield HD RL | | | | | | | |
| or an approved equivalent) with attached VELCRO | | | | | | | |
| 0012AF | INSTALL FIBERGLASS FACED, HIGH DENSITY | SF | 125000 | $ - 0 | $0.00 | 25,000 | $ - 0 | $ - 0 |
| GYPSUM BOARD 1/2 INCH THICKNESS OVER | | | | | | | |
| INSULATION AS A COVERBOARD (DENS-DECK | | | | | | | |
| PRIME OR EQUIVALENT) | | | | | | | |
| 0012AG | INSTALL VENTED BASE SHEET WITH | SF | 225000 | $ - 0 | $0.00 | 25,000 | $ - 0 | $ - 0 |
| GRID WAFFLE PATTERN | | | | | | | |
| 0012AH | INSTALL NONVENTED BASE SHEET WITH | SF | 190000 | $ - 0 | $0.00 | 15,000 | $ - 0 | $ - 0 |
| GRID WAFFLE PATTERN | | | | | | | |
| 0012AJ | INSTALL SNOW/ICE SHIELD (WINTER | SF | 125000 | $ - 0 | $0.00 | 40,000 | $ - 0 | $ - 0 |
| GUARD WATERPROOFING SHINGLE UNDER- | | | | | | | |
| LAYMENT) ON ROOF EAVES, VALLEYS | | | | | | | |
| AND SLOPE ROOF AREAS. | | | | | | | |
0013 SHEET METAL
| 0013AA | REMOVE, DISPOSE AND REPLACE OR | SF | 30000 | $ - 0 | $0.00 | 15,000 | $ - 0 | $ - 0 |
| INSTALL NEW FLASHING, FASCIA, | | | | | | | |
| SOFFIT, OR GRAVEL STOP ON MINOR | | | | | | | |
| FLAT, PITCHED OR CURVED SURFACES | | | | | | | |
| WITH ALUMINUM | | | | | | | |
| 0013AB | REMOVE, DISPOSE AND REPLACE OR | SF | 1000 | $ - 0 | $0.00 | 0 | $ - 0 | $ - 0 |
| INSTALL NEW FLASHING, FASCIA, | | | | | | | |
| SOFFIT, OR GRAVEL STOP ON MINOR | | | | | | | |
| FLAT, PITCHED OR CURVED SURFACES | | | | | | | |
| WITH COPPER | | | | | | | |
| 0013AC | REMOVE, DISPOSE AND REPLACE OR | SF | 1000 | $ - 0 | $0.00 | 1,000 | $ - 0 | $ - 0 |
| INSTALL NEW FLASHING, FASCIA, | | | | | | | |
| SOFFIT OR GRAVEL STOP ON MINOR | | | | | | | |
| FLAT, PITCHED OR CURVED SURFACES | | | | | | | |
| WITH STAINLESS STEEL | | | | | | | |
| 0013AD | REMOVE, DISPOSE, AND REPLACE OR | SF | 30000 | $ - 0 | $0.00 | 5,000 | $ - 0 | $ - 0 |
| INSTALL NEW FLASHING, FASCIA, | | | | | | | |
| SOFFIT, OR GRAVEL STOP ON MINOR | | | | | | | |
| FLAT, PITCHED OR CURVED SURFACES | | | | | | | |
| USING ALUMINUM SIDING | | | | | | | |
| 0013AE | REMOVE, DISPOSE, AND REPLACE OR | SF | 3750 | $ - 0 | $0.00 | 750 | $ - 0 | $ - 0 |
| INSTALL NEW FLASHING, FASCIA, | | | | | | | |
| SOFFIT OR GRAVEL STOP ON MINOR | | | | | | | |
| FLAT, PITCHED OR CURVED SURFACES | | | | | | | |
| USING VINYL SIDING AS FLASHING | | | | | | | |
| GRAVEL STOP, EIGHT (8) INCH HIGH | | | | | | | |
| 0013AF | REMOVE, DISPOSE AND REPLACE OR | LF | 3000 | $ - 0 | $0.00 | 750 | $ - 0 | $ - 0 |
| INSTALL NEW 8" HIGH GRAVEL STOP | | | | | | | |
| ALUMINUM | | | | | | | |
| 0013AG | REMOVE, DISPOSE AND REPLACE OR | LF | 1500 | $ - 0 | $0.00 | 0 | $ - 0 | $ - 0 |
| INSTALL NEW 8" HIGH GRAVEL STOP | | | | | | | |
| COPPER | | | | | | | |
| 0013AH | REMOVE, DISPOSE AND REPLACE OR | LF | 21250 | $ - 0 | $0.00 | 15,000 | $ - 0 | $ - 0 |
| INSTALL NEW ALUMINUM DRIP EDGE | | | | | | | |
0014 BASE FLASHING
| 0014AA | REMOVE, DISPOSE AND REPLACE OR | SF | 3000 | $ - 0 | $0.00 | 500 | $ - 0 | $ - 0 |
| INSTALL NEW BASE FLASHING ALUMINUM | | | | | | | |
| 0014AB | REMOVE, DISPOSE AND REPLACE OR | SF | 300 | $ - 0 | $0.00 | 0 | $ - 0 | $ - 0 |
| INSTALL NEW BASE FLASHING COPPER | | | | | | | |
| 0014AC | REMOVE, DISPOSE AND REPLACE OR | SF | 3000 | $ - 0 | $0.00 | 500 | $ - 0 | $ - 0 |
| INSTALL NEW BASE FLASHING | | | | | | | |
| STAINLESS STEEL | | | | | | | |
| 0015 | REMOVAL, DISPOSAL AND REPLACEMENT |
| OF REGLETS |
| 0015AA | REMOVAL, DISPOSAL AND REPLACE OR | LF | 1100 | $ - 0 | $0.00 | 250 | $ - 0 | $ - 0 |
| INSTALL NEW METAL REGLETS ALUMINUM | | | | | | | |
| 0015AB | REMOVAL, DISPOSAL AND REPLACE OR | LF | 750 | $ - 0 | $0.00 | 0 | $ - 0 | $ - 0 |
| INSTALL NEW METAL REGLETS COPPER | | | | | | | |
0016 COUNTER AND VALLEY FLASHING
| 0016AA | REMOVAL, DISPOSAL AND REPLACE OR | SF | 17500 | $ - 0 | $0.00 | 7,500 | $ - 0 | $ - 0 |
| INSTALL NEW STEPPED, CAP, COUNTER | | | | | | | |
| OR VALLEY FLASHING WITH ALUMINUM | | | | | | | |
| 0016AB | REMOVAL, DISPOSAL AND REPLACE OR | SF | 1000 | $ - 0 | $0.00 | 0 | $ - 0 | $ - 0 |
| INSTALL NEW STEPPED, CAP, COUNTER | | | | | | | |
| OR VALLEY FLASHING WITH COPPER | | | | | | | |
| 0016AC | REMOVAL, DISPOSAL AND REPLACE OR | SF | 750 | $ - 0 | $0.00 | 750 | $ - 0 | $ - 0 |
| INSTALL NEW STEPPED, CAP, COUNTER | | | | | | | |
| OR VALLEY FLASHING WITH STAINLESS | | | | | | | |
| STEEL | | | | | | | |
0017 VENT PIPE FLASHING
| 0017AA | REMOVAL, DISPOSE AND REPLACE OR | EA | 750 | $ - 0 | $0.00 | 45 | $ - 0 | $ - 0 |
| INSTALL NEW VENT PIPE FLASHING | | | | | | | |
| ALUMINUM WITH LEAD RING > 0"UP TO | | | | | | | |
| 2" PIPE | | | | | | | |
| 0017AB | REMOVAL, DISPOSE AND REPLACE OR | EA | 250 | $ - 0 | $0.00 | 45 | $ - 0 | $ - 0 |
| INSTALL NEW VENT PIPE FLASHING | | | | | | | |
| ALUMINUM WITH LEAD RING >2" UP TO | | | | | | | |
| 4" PIPE | | | | | | | |
0018 COPPER WITH LEAD RING
| 0018AA | REMOVAL, DISPOSE AND REPLACE OR | EA | 10 | $ - 0 | $0.00 | 10 | $ - 0 | $ - 0 |
| INSTALL NEW VENT PIPE FLASHING | | | | | | | |
| COPPER WITH LEAD RING UP TO 2" PIPE | | | | | | | |
| 0018AB | REMOVAL, DISPOSE AND REPLACE OR | EA | 50 | $ - 0 | $0.00 | 10 | $ - 0 | $ - 0 |
| INSTALL NEW VENT PIPE FLASHING | | | | | | | |
| COPPER WITH LEAD RING >2" UP TO 3" PIPE | | | | | | | |
| 0018AC | REMOVAL, DISPOSE AND REPLACE OR | EA | 150 | $ - 0 | $0.00 | 25 | $ - 0 | $ - 0 |
| INSTALL NEW VENT PIPE FLASHING | | | | | | | |
| COPPER WITH LEAD RING >3" UP TO 4" PIPE | | | | | | | |
0019 GUTTERS AND SCUPPER LINING
| 0019AA | REMOVAL, DISPOSE AND REPLACE OR | LF | 17500 | $ - 0 | $0.00 | 7,500 | $ - 0 | $ - 0 |
| INSTALL NEW "K" TYPE OR HALF ROUND | | | | | | | |
| GUTTERS, 21" TO 25" GIRTH | | | | | | | |
| ALUMINUM | | | | | | | |
| 0019AB | REMOVAL, DISPOSE AND REPLACE OR | LF | 12500 | $ - 0 | $0.00 | 0 | $ - 0 | $ - 0 |
| INSTALL NEW "K" TYPE OR HALF ROUND | | | | | | | |
| GUTTERS, 21" TO 25" GIRTH | | | | | | | |
| COPPER | | | | | | | |
| 0019AC | REMOVAL, DISPOSE AND REPLACE OR | LF | 1000 | $ - 0 | $0.00 | 1,000 | $ - 0 | $ - 0 |
| INSTALL NEW "K" TYPE OR HALF ROUND | | | | | | | |
| GUTTERS, 21" TO 25" GIRTH | | | | | | | |
| STAINLESS STEEL | | | | | | | |
| 0019AD | REMOVAL, DISPOSE AND REPLACE OR | LF | 6000 | $ - 0 | $0.00 | 1,000 | $ - 0 | $ - 0 |
| INSTALL NEW "K" TYPE OR HALF ROUND | | | | | | | |
| GUTTERS, 26" TO 30" GIRTH | | | | | | | |
| ALUMINUM | | | | | | | |
| 0019AE | REMOVAL, DISPOSE AND REPLACE OR | LF | 2500 | $ - 0 | $0.00 | 0 | $ - 0 | $ - 0 |
| INSTALL NEW "K" TYPE OR HALF ROUND | | | | | | | |
| GUTTERS, 26" TO 30" GIRTH | | | | | | | |
| COPPER | | | | | | | |
| 0019AF | REMOVAL, DISPOSE AND REPLACE OR | LF | 75 | $ - 0 | $0.00 | 75 | $ - 0 | $ - 0 |
| INSTALL NEW "K" TYPE OR HALF ROUND | | | | | | | |
| GUTTERS, 26" TO 30" GIRTH | | | | | | | |
| STAINLESS STEEL | | | | | | | |
| 0019AG | REMOVAL, DISPOSE AND REPLACE OR | SF | 400 | $ - 0 | $0.00 | 400 | $ - 0 | $ - 0 |
| INSTALL NEW BUILT IN GUTTER AND | | | | | | | |
| SCUPPER LINING ALUMINUM | | | | | | | |
| 0019AH | REMOVAL, DISPOSE AND REPLACE OR | SF | 250 | $ - 0 | $0.00 | 0 | $ - 0 | $ - 0 |
| INSTALL NEW BUILT IN GUTTER AND | | | | | | | |
| SCUPPER LINING COPPER | | | | | | | |
| 0019AI | REMOVE DISPOSE AND REPLACE OR | LF | 12500 | $ - 0 | $0.00 | 2,500 | $ - 0 | $ - 0 |
| INSTALL NEW 6 INCH BOX STYLE GUTTERS | | | | | | | |
| ALUMINUM | | | | | | | |
0020 DOWNSPOUTS AND LEADERS
| 0020AA | REMOVAL, DISPOSE AND REPLACE OR | LF | 10500 | $ - 0 | $0.00 | 5,000 | $ - 0 | $ - 0 |
| INSTALL NEW DOWNSPOUTS OR LEADERS; | | | | | | | |
| 3"x4" RECTANGULAR ALUMINUM | | | | | | | |
| 0020AB | REMOVAL, DISPOSE AND REPLACE OR | LF | 1100 | $ - 0 | $0.00 | 0 | $ - 0 | $ - 0 |
| INSTALL NEW DOWNSPOUTS OR LEADERS; | | | | | | | |
| 3"x4" RECTANGULAR COPPER | | | | | | | |
| 0020AC | REMOVAL, DISPOSE AND REPLACE OR | LF | 8000 | $ - 0 | $0.00 | 3,000 | $ - 0 | $ - 0 |
| INSTALL NEW DOWNSPOUTS OR LEADERS; | | | | | | | |
| 5" X 4" RECTANGULAR ALUMINUM | | | | | | | |
| 0020AD | REMOVAL, DISPOSE AND REPLACE OR | LF | 3000 | $ - 0 | $0.00 | 1,000 | $ - 0 | $ - 0 |
| INSTALL NEW DOWNSPOUTS OR LEADERS; | | | | | | | |
| 5" X 4" RECTANGULAR STAINLESS STEEL | | | | | | | |
| 0020AE | REMOVAL, DISPOSE AND REPLACE OR | LF | 500 | $ - 0 | $0.00 | 100 | $ - 0 | $ - 0 |
| INSTALL NEW DOWNSPOUTS OR LEADERS; | | | | | | | |
| 4" ROUND TYPE ALUMINUM | | | | | | | |
| 0020AF | REMOVAL, DISPOSE AND REPLACE OR | LF | 250 | $ - 0 | $0.00 | 0 | $ - 0 | $ - 0 |
| INSTALL NEW DOWNSPOUTS OR LEADERS; | | | | | | | |
| 4" ROUND TYPE COPPER | | | | | | | |
0021 ROOF DRAINS AND CONDUCTOR HEADS
| 0021AA | REMOVAL, DISPOSE AND REPLACE OR | EA | 25 | $ - 0 | $0.00 | 8 | $ - 0 | $ - 0 |
| INSTALL NEW ROOF DRAINS AND | | | | | | | |
| CONDUCTOR HEAD, CAST IRON 10" TOP | | | | | | | |
| >0" UP TO 3" PIPE | | | | | | | |
| 0021AB | REMOVAL, DISPOSE AND REPLACE OR | EA | 30 | $ - 0 | $0.00 | 15 | $ - 0 | $ - 0 |
| INSTALL NEW ROOF DRAINS AND | | | | | | | |
| CONDUCTOR HEAD, CAST IRON 10" TOP | | | | | | | |
| >3" UP TO 5" PIPE | | | | | | | |
| 0021AC | REMOVE, DISPOSE AND INSTALL NEW | SF | 1250 | $ - 0 | $0.00 | 250 | $ - 0 | $ - 0 |
| SHEET LEAD ON DRAIN BOWLS BEING | | | | | | | |
| REPLACED UNDER CLINS AA OR AB ABOVE | | | | | | | |
| 0021AD | REMOVE, DISPOSE AND INSTALL NEW | LF | 250 | $ - 0 | $0.00 | 75 | $ - 0 | $ - 0 |
| DRAIN PIPING INTERNAL TO BUILDING, 4" TO | | | | | | | |
| 6" PIPING | | | | | | | |
0022 CONDUCTOR HEADS
| 0022AA | REMOVAL, DISPOSE AND REPLACE OR | SF | 20 | $ - 0 | $0.00 | 5 | $ - 0 | $ - 0 |
| INSTALL NEW CONDUCTOR HEAD | | | | | | | |
| ALUMINUM | | | | | | | |
| 0022AB | REMOVAL, DISPOSE AND REPLACE OR | SF | 100 | $ - 0 | $0.00 | 20 | $ - 0 | $ - 0 |
| INSTALL NEW CONDUCTOR HEAD | | | | | | | |
| COPPER | | | | | | | |
| 0023 | CLEANING DOWNSPOUTS, GUTTERS, ROOF |
| DRAINS AND CONDUCTOR HEADS |
| 0023AA | DOWNSPOUTS AND LEADER CLEANING | LF | 49000 | $ - 0 | $0.00 | 5,000 | $ - 0 | $ - 0 |
| ALL SIZES | | | | | | | |
| 0023AB | GUTTER AND SCUPPER CLEANING (BUILT | LF | 89250 | $ - 0 | $0.00 | 5,000 | $ - 0 | $ - 0 |
| IN, K AND HALF ROUND) ALL SIZES | | | | | | | |
| 0023AC | ROOF DRAIN CLEANING- INTERIOR TO | EA | 160 | $ - 0 | $0.00 | 60 | $ - 0 | $ - 0 |
| BUILDING | | | | | | | |
0024 MISCELLANEOUS METAL/VINYL WORK
| 0024AA | REMOVAL, DISPOSE AND REPLACE OR | LF | 250 | $ - 0 | $0.00 | 0 | $ - 0 | $ - 0 |
| INSTALL NEW COPPER RIDGE ROLL | | | | | | | |
| CAPPING | | | | | | | |
| 0024AB | REMOVAL, DISPOSE AND REPLACE OR | SF | 12600 | $ - 0 | $0.00 | 1,200 | $ - 0 | $ - 0 |
| INSTALL NEW PREFINISHED ALUMINUM | | | | | | | |
| COVERING ON RAKE AND OR FASCIA | | | | | | | |
| BOARD | | | | | | | |
| 0024AC | REMOVAL, DISPOSE AND REPLACE OR | LF | 1500 | $ - 0 | $0.00 | 75 | $ - 0 | $ - 0 |
| INSTALL NEW VENTED VINYL SOFFIT | | | | | | | |
| 0024AD | REMOVE, DISPOSE AND REPLACE OR | LF | 1500 | $ - 0 | $0.00 | 75 | $ - 0 | $ - 0 |
| INSTALL NEW NON-VENTED VINYL SOFFIT | | | | | | | |
0025 ROOF DECK REPAIR
| 0025AA | REMOVE AND DISPOSE LIGHT WEIGHT | SF/IN | 42500 | $ - 0 | $0.00 | 24,000 | $ - 0 | $ - 0 |
| CONCRETE OR GYPSUM ROOF DECK | | | | | | | |
0025AB PRIME CONCRETE DECK WITH HOT ASPHALT SF 42500 $ - 0 $0.00 24,000 $ - 0 $ - 0
0025AC PRIME CONCRETE DECK WITH ASPHALT PRIMER SF 42500 $ - 0 $0.00 24,000 $ - 0 $ - 0
| 0025AD | PATCHING OF LIGHT WEIGHT CONCRETE | SF/IN | 20000 | $ - 0 | $0.00 | 500 | $ - 0 | $ - 0 |
| ROOF DECK | | | | | | | |
| 0025AE | REMOVE AND DISPOSE ROOF DECKING | SF | 20000 | $ - 0 | $0.00 | 5,000 | $ - 0 | $ - 0 |
| (WOOD PLANKS) | | | | | | | |
0025AF INSTALL ROOF DECKING (WOOD PLANKS) SF 20000 $ - 0 $0.00 5,000 $ - 0 $ - 0
| 0025AG | REMOVE AND DISPOSE PLYWOOD | SF | 3000 | $ - 0 | $0.00 | 1,000 | $ - 0 | $ - 0 |
| SHEATHING | | | | | | | |
| 0025AH | INSTALL PLYWOOD SHEATHING 1/2" | SF | 275000 | $ - 0 | $0.00 | 45,000 | $ - 0 | $ - 0 |
| SCREWED IN PLACE | | | | | | | |
| 0025AJ | INSTALL PLYWOOD SHEATHING 3/4" | SF | 17500 | $ - 0 | $0.00 | 1,250 | $ - 0 | $ - 0 |
| SCREWED IN PLACE | | | | | | | |
| 0025AK | INSTALL PLYWOOD SHEATHING 1" | SF | 17500 | $ - 0 | $0.00 | 1,250 | $ - 0 | $ - 0 |
| SCREWED IN PLACE | | | | | | | |
| 0025AL | REMOVE AND DISPOSE OF EXISITNG | SF | 5000 | $ - 0 | $0.00 | 500 | $ - 0 | $ - 0 |
| CORRUGATED METAL ROOF DECK | | | | | | | |
| 0025AM | INSTALL NEW OPEN TYPE, GALVANIZED, | SF | 15625 | $ - 0 | $0.00 | 5,265 | $ - 0 | $ - 0 |
| 1-1/2 INCH DEEP WIDE RIB, 20 GAGE METAL | | | | | | | |
| DECKING | | | | | | | |
| 0025AN | PATCH CORRUGATED METAL DECKING | SF | 4500 | $ - 0 | $0.00 | 450 | $ - 0 | $ - 0 |
| WITH 20 GAGE GALVANIZED METAL | | | | | | | |
| DECKING, 1-1/2 INCH DEEP WIDE RIB PANEL | | | | | | | |
0026 MISCELLANEOUS WOOD
| 0026AA | REMOVE, DISPOSE AND REPLACE WOOD | BF | 12500 | $ - 0 | $0.00 | 1,250 | $ - 0 | $ - 0 |
| RAFTERS AND LOOKOUTS | | | | | | | |
| 0026AB | REMOVE, DISPOSE AND REPLACE WOOD | LF | 2500 | $ - 0 | $0.00 | 250 | $ - 0 | $ - 0 |
| CANTS | | | | | | | |
| 0026AC | REMOVE, DISPOSE AND REPLACE FIBER | LF | 20000 | $ - 0 | $0.00 | 2,000 | $ - 0 | $ - 0 |
| CANTS | | | | | | | |
| 0026AD | REMOVE, DISPOSE, AND REPLACE OR INSTALL | LF | 20000 | $ - 0 | $0.00 | 2,000 | $ - 0 | $ - 0 |
| NEW ROCK WOOL/MINERAL WOOL CANT STRIP | | | | | | | |
0026AE REMOVE, DISPOSE AND REPLACE NAILERS BF 75000 $ - 0 $0.00 4,500 $ - 0 $ - 0
| 0026AF | REMOVE, DISPOSE AND REPLACE WOOD | SF | 10000 | $ - 0 | $0.00 | 1,000 | $ - 0 | $ - 0 |
| SOFFIT | | | | | | | |
| 0026AG | REMOVE, DISPOSE AND REPLACE CORNICE | LF | 625 | $ - 0 | $0.00 | 125 | $ - 0 | $ - 0 |
| TRIM | | | | | | | |
| 0026AH | REMOVE, DISPOSE AND REPLACE RAKE | BF | 22500 | $ - 0 | $0.00 | 2,250 | $ - 0 | $ - 0 |
| TRIM | | | | | | | |
| 0026AJ | REMOVE, DISPOSE AND REPLACE FASCIA | BF | 25000 | $ - 0 | $0.00 | 2,500 | $ - 0 | $ - 0 |
| BOARD | | | | | | | |
| 0026AK | REMOVE, DISPOSE AND REPLACE WOOD | BF | 2500 | $ - 0 | $0.00 | 250 | $ - 0 | $ - 0 |
| TRUSS MEMBERS | | | | | | | |
| 0027 | CAULKING, BACKER ROD AND EXPANSION |
| JOINTS |
0027AA INSTALL CAULKING LF 25000 $ - 0 $0.00 2,500 $ - 0 $ - 0
0027AB INSTALL BACKER ROD LF 25000 $ - 0 $0.00 2,500 $ - 0 $ - 0
| 0027AC | REMOVE, DISPOSE, AND REPLACE OR INSTALL | LF | 15000 | $ - 0 | $0.00 | 1,500 | $ - 0 | $ - 0 |
| NEW PRE-MANUFACTURED EXPANSION JOINT | | | | | | | |
| COVERS (EXPANDA-FLASH OR APPROVED | | | | | | | |
| EQUIVALENT) ALUMINUM | | | | | | | |
| 0027AD | REMOVE, DISPOSE, AND REPLACE OR INSTALL | LF | 15000 | $ - 0 | $0.00 | 1,500 | $ - 0 | $ - 0 |
| NEW PRE-MANUFACTURED EXPANSION JOINT | | | | | | | |
| COVERS (EXPANDA-FLASH OR APPROVED | | | | | | | |
| EQUIVALENT) STAINLESS STEEL | | | | | | | |
| 0027AE | REMOVE, DISPOSE, AND REPLACE OR INSTALL | LF | 15000 | $ - 0 | $0.00 | 1,500 | $ - 0 | $ - 0 |
| NEW CLOSED CELL RESILIENT FOAM TUBE INSIDE | | | | | | | |
| ROOF EXPANSION JOINTS ( 1 INCH TO 4 | | | | | | | |
| INCHES IN DIAMETER) | | | | | | | |
0028 PAINTING
| 0028AA | PREPARE SURFACE, PRIME AND PAINT | SF | 1250 | $ - 0 | $0.00 | 500 | $ - 0 | $ - 0 |
| FERROUS SURFACES | | | | | | | |
| 0028AB | PREPARE SURFACE, PRIME AND PAINT | SF | 600 | $ - 0 | $0.00 | 100 | $ - 0 | $ - 0 |
| GALVANIZED SURFACES | | | | | | | |
| 0028AC | PREPARE SURFACE, PRIME AND PAINT | SF | 3000 | $ - 0 | $0.00 | 300 | $ - 0 | $ - 0 |
| WOOD SURFACES | | | | | | | |
| 0028AD | PREPARE SURFACE, PRIME AND PAINT | SF | 600 | $ - 0 | $0.00 | 100 | $ - 0 | $ - 0 |
| ALUMINUM AND ALUMINUM ALLOY SURFACES | | | | | | | |
0029 SPLASH BLOCKS
| 0029AA | INSTALL PRECAST CONCRETE SPLASH | EA | 500 | $ - 0 | $0.00 | 50 | $ - 0 | $ - 0 |
| BLOCKS AT DOWNSPOUTS | | | | | | | |
0030 ROOF INSPECTION AND TESTING
| 0030AA | THERMOGRAPHIC TESTING | SF | 400000 | $ - 0 | $0.00 | 125,000 | $ - 0 | $ - 0 |
| (INFRARED SCANNING)-INITIAL OR DIAGNOSTIC | | | | | | | |
| INSEPCTION FOR WATER INFILTRATION | | | | | | | |
| 0030AB | THERMOGRAPHIC TESTING (IR SCAN) EIGHT | SF | 250000 | $ - 0 | $0.00 | 75,000 | $ - 0 | $ - 0 |
| MONTH WARRANTY INSPECTION | | | | | | | |
| 0030AC | INSULATION INSPECTION | EA | 125 | $ - 0 | $0.00 | 75 | $ - 0 | $ - 0 |
| (CORE SAMPLES) | | | | | | | |
| 0030AD | TEST FOR ASBESTOS CONTAINING | EA | 75 | $ - 0 | $0.00 | 45 | $ - 0 | $ - 0 |
| ROOFING MATERIALS | | | | | | | |
| 0030AE | TCLP TESTING FOR LEAD-48 HR | EA | 5 | $ - 0 | $0.00 | 2 | $ - 0 | $ - 0 |
| TURNAROUND | | | | | | | |
| 0030AF | TCLP TESTING FOR LEAD-96 HR | EA | 25 | $ - 0 | $0.00 | 15 | $ - 0 | $ - 0 |
| TURNAROUND | | | | | | | |
| 0030AG | TCLP TESTING FOR LEAD-120 HR | EA | 75 | $ - 0 | $0.00 | 25 | $ - 0 | $ - 0 |
| TURNAROUND | | | | | | | |
| 0030AH | CONDUCT LOW VOLTAGE ELECTRONIC LEAK | SF | 250000 | $ - 0 | $0.00 | 50,000 | $ - 0 | $ - 0 |
| DETECTION TESTING ON MEMBRANE ROOF | | | | | | | |
| SYSTEMS | | | | | | | |
0031 MISCELLANEOUS
0031AA DRYVIT CUT/PATCH SF 5000 $ - 0 $0.00 1,000 $ - 0 $ - 0
| 0031AB | CUT AND REPOINT MASONRY (BRICK | LF | 4750 | $ - 0 | $0.00 | 1,750 | $ - 0 | $ - 0 |
| AND BLOCK) | | | | | | | |
0031AC CUT AND REPOINT MASONRY (STONE) LF 2500 $ - 0 $0.00 250 $ - 0 $ - 0
| 0031AD | CUT AND PATCH COATED FOAM ROOF TO 1" | SF | 6250 | $ - 0 | $0.00 | 625 | $ - 0 | $ - 0 |
| DEEP | | | | | | | |
| 0031AE | INSTALL "RIDGE-IT" ANCHOR SYSTEM ON | EA | 1125 | $ - 0 | $0.00 | 50 | $ - 0 | $ - 0 |
| SLOPED ROOF SYSTEMS | | | | | | | |
0032 TEMPORARY SCAFFOLDING
| 0032AA | CONSTRUCT FREE STANDING TEMPORARY | VLF | 500 | $ - 0 | $0.00 | 100 | $ - 0 | $ - 0 |
| SCAFFOLDING STAIR TOWER TO PROVIDE SAFE | | | | | | | |
| ACCESS TO ROOF (Vertical linear feet) | | | | | | | |
| UP TO 25 VERTICAL LINEAR FEET | | | | | | | |
| 0032AB | CONSTRUCT FREE STANDING TEMPORARY | VLF | 500 | $ - 0 | $0.00 | 100 | $ - 0 | $ - 0 |
| SCAFFOLDING STAIR TOWER FOR ROOF | | | | | | | |
| ACCESS 26 TO 35 VERTICAL LINEAR FEET | | | | | | | |
| 0032AC | CONSTRUCT FREE STANDING TEMPORARY | VLF | 500 | $ - 0 | $0.00 | 100 | $ - 0 | $ - 0 |
| SCAFFOLDING STAIR TOWER FOR ROOF | | | | | | | |
| ACCESS 36 TO 45 VERTICAL LINEAR FEET | | | | | | | |
| 0032AD | CONSTRUCT FREE STANDING TEMPORARY | VLF | 500 | $ - 0 | $0.00 | 100 | $ - 0 | $ - 0 |
| SCAFFOLDING STAIR TOWER FOR ROOF ACCESS | | | | | | | |
| ACCESS 46 VLF AND GREATER | | | | | | | |
| 0032AE | CONSTRUCT FIXED TEMPORARY SCAFFOLDING | VLF | 500 | $ - 0 | $0.00 | 100 | $ - 0 | $ - 0 |
| STAIR TOWER FOR ROOF ACCESS | | | | | | | |
| UP TO 25 VERTICAL LINEAR FEET | | | | | | | |
| 0032AF | CONSTRUCT FIXED TEMPORARY SCAFFOLDING | VLF | 500 | $ - 0 | $0.00 | 100 | $ - 0 | $ - 0 |
| STAIR TOWER FOR ROOF ACCESS | | | | | | | |
| 26 VLF TO 35 VLF | | | | | | | |
| 0032AG | CONSTRUCT FIXED TEMPORARY SCAFFOLDING | VLF | 500 | $ - 0 | $0.00 | 100 | $ - 0 | $ - 0 |
| STAIR TOWER FOR ROOF ACCESS | | | | | | | |
| 36 VLF TO 45 VLF | | | | | | | |
| 0032AH | CONSTRUCT FIXED TEMPORARY SCAFFOLDING | VLF | 500 | $ - 0 | $0.00 | 100 | $ - 0 | $ - 0 |
| STAIR TOWER FOR ROOF ACCESS | | | | | | | |
| 46 VLF AND GREATER | | | | | | | |
| 0032AI | CONSTRUCT FREE STANDING, TEMPORARY | CSF | 500 | $ - 0 | $0.00 | 100 | $ - 0 | $ - 0 |
| SCAFFOLDING AROUND BUILDING PERIMETER | | | | | | | |
| TO SUPPORT ROOF WORK. Price to include | | | | | | | |
| walk boards, rails, toe boards and outriggers (as | | | | | | | |
| required) | | | | | | | |
| 0032AJ | CONSTRUCT FIXED (ATTACHED TO BUILDING ) | CSF | 500 | $ - 0 | $0.00 | 100 | $ - 0 | $ - 0 |
| TEMPORARY SCAFFOLDING AROUND BUILDING | | | | | | | |
| PERIMETER TO SUPPORT ROOF WORK. Price to | | | | | | | |
| include walk boards, rails, toe boards and out riggers | | | | | | | |
| (as required) | | | | | | | |
0033 SNOW GUARDS & VENTILATORS
| 0033AA | COPPER SNOW GUARD, NO. 100 BB | EA | 500 | $ - 0 | $0.00 | 0 | $ - 0 | $ - 0 |
| INSTALLED IN CONJUNCTION WITH | | | | | | | |
| INSTALLATION OF NEW SLATE OR | | | | | | | |
| MANUFACTURED SLATE 630 LBS. EA, | | | | | | | |
| BRASS CLEAT .O80 THICK 1/2 HARD | | | | | | | |
| COPPER CLEAT (SHOE) .050 THICK | | | | | | | |
| 0033AB | INSTALL MECHANICALLY FASTENED, CLEAR | EA | 3500 | $ - 0 | $0.00 | 50 | $ - 0 | $ - 0 |
| POLYCARBONATE SNOW AND ICE GUARDS ON | | | | | | | |
| SLOPED ROOF SYSTEMS (SNO-BLX™ , SNO-JAX™ | | | | | | | |
| OR AN APPROVED EQUIVALENT) | | | | | | | |
| 0033AC | INSTALL MECHANICALLY FASTENED ALUMINUM | EA | 1500 | $ - 0 | $0.00 | 500 | $ - 0 | $ - 0 |
| SNOW AND ICE GUARDS ON SLOPED ROOF | | | | | | | |
| SYSTEMS | | | | | | | |
| 0033AD | INSTALL MECHANICALLY FASTENED STAINLESS | EA | 1500 | $ - 0 | $0.00 | 500 | $ - 0 | $ - 0 |
| STEEL SNOW AND ICE GUARDS ON SLOPED ROOF | | | | | | | |
| SYSTEMS | | | | | | | |
| 0033AE | INSTALL DOUBLE RAIL SNOW FENCE WITH ICE | LF | 10000 | $ - 0 | $0.00 | 500 | $ - 0 | $ - 0 |
| CLIPS TO METAL ROOF SYSTEMS 3/12 PITCH OR | | | | | | | |
| GREATER (S-5! CLIPS ANF TWO RAIL SNOW-FENCE | | | | | | | |
| ™ WITH SNO-CLIPS ™ OR APPROVED EQUIVALENT) | | | | | | | |
| 0033AF | INSTALL S-5! BRACKET (OR EQUIVALENT) WITH | EA | 10000 | $ - 0 | $0.00 | 500 | $ - 0 | $ - 0 |
| RAM-GUARD ™ SNOW RETENTION DEVICE (OR | | | | | | | |
| EQUIVALENT) TO METAL ROOF SYSTEMS 3/12 | | | | | | | |
| PITCH OR GREATER | | | | | | | |
| 0033AG | REMOVAL, DISPOSE AND REPLACE OR | LF | 3250 | $ - 0 | $0.00 | 325 | $ - 0 | $ - 0 |
| INSTALL NEW ROOF RIDGE VENTILATOR | | | | | | | |
| 0033AH | REMOVE AND DISPOSE OF METAL ROOF | CF | 5000 | $ - 0 | $0.00 | 500 | $ - 0 | $ - 0 |
| VENTILATORS. REMOVE VENTILATOR | | | | | | | |
| AND ALL ASSOCIATED HARDWARE. TURN | | | | | | | |
| ALL METAL INTO METAL SALVAGE | | | | | | | |
| 0033AJ | DISCONNECT AND RECONNECT HVAC UNIT | EA | 250 | $ - 0 | $0.00 | 25 | $ - 0 | $ - 0 |
| (1-3 TON) TO RAISE 18" MINIMUM TO | | | | | | | |
| INCLUDE ALL PIPING, ELECTRICAL, | | | | | | | |
| CURBING AND STEEL | | | | | | | |
| 0033AK | PROVIDE GALVANIZED RAIN HOOD | SF | 500 | $ - 0 | $0.00 | 50 | $ - 0 | $ - 0 |
| AROUND STACKS | | | | | | | |
0033AL 8" TURBINE VENTILATOR EA 100 $ - 0 $0.00 10 $ - 0 $ - 0
0033AM 14" TURBINE VENTILATOR EA 225 $ - 0 $0.00 25 $ - 0 $ - 0
| 0033AN | REMOVE AND DISPOSE OF ABANDONED ROOF | CF | 2500 | $ - 0 | $0.00 | 500 | $ - 0 | $ - 0 |
| MOUNTED EQUIPMENT AND CURBS TO INCLUDE | | | | | | | |
| ELECTRICAL ISOLATION AND DISCONNECT FROM | | | | | | | |
| SOURCE PANEL AS APPLICABLE. | | | | | | | |
0034 LIGHTENING PROTECTION SYSTEMS
| 0034AA | REMOVE, SALVAGE AND REINSTALL LIGHTENING | EA | 2500 | $ - 0 | $0.00 | 500 | $ - 0 | $ - 0 |
| PROTECTION SYSTEM (LPS) AIR TERMINAL | | | | | | | |
| COPPER AND/OR ALUMINUM | | | | | | | |
| 0034AB | REMOVE, SALVAGE AND REINSTALL LIGHTENING | EA | 3750 | $ - 0 | $0.00 | 500 | $ - 0 | $ - 0 |
| PROTECTION SYSTEM (LPS) MOUNTING BRACKET | | | | | | | |
| COPPER AND/OR ALUMINUM | | | | | | | |
| 0034AC | REMOVE, SALVAGE AND REINSTALL LIGHTENING | EA | 6250 | $ - 0 | $0.00 | 1,250 | $ - 0 | $ - 0 |
| PROTECTION SYSTEM (LPS) COMPONENTS AND | | | | | | | |
| CONDUCTORS, COPPER AND/OR ALUMINUM | | | | | | | |
| 0034AD | PERFORM CONTINUITY AND ACCEPTANCE | EA | 25 | $ - 0 | $0.00 | 15 | $ - 0 | $ - 0 |
| TESTING FOR LIGHTENING PROTECTION SYSTEM | | | | | | | |
| AFTER REINSTALLATION | | | | | | | |
0035 ROOF HATCHES AND LADDERS
| 0035AA | REMOVE, DISPOSE AND REPLACE OR INSTALL | EA | 25 | $ - 0 | $0.00 | 10 | $ - 0 | $ - 0 |
| NEW LOCKABLE, INSULATED ALUMINUM ROOF | | | | | | | |
| ACCESS HATCH, (BILCO TYPE "S", TYPE "E", | | | | | | | |
| VERSA-MOUNT ™ OR EQUIVALENT), | | | | | | | |
| 2.5 FT BY 3 FT OPENING | | | | | | | |
| 0035AB | INSTALL NEW BILCO LADDER-UP ™ SAFETY POST | EA | 40 | $ - 0 | $0.00 | 10 | $ - 0 | $ - 0 |
| ON NEW OR EXISTING ROOF ACCESS HATCH | | | | | | | |
| LADDERS | | | | | | | |
| 0035AC | INSTALL OSHA COMPLIANT GUARD RAIL | EA | 50 | $ - 0 | $0.00 | 10 | $ - 0 | $ - 0 |
| SYSTEM TO NEW AND/OR EXISTING ROOF ACCESS | | | | | | | |
| HATCHES (BILCO BIL-GUARD ™ OR EQUIVALENT) | | | | | | | |
| 0035AD | INSTALL OSHA COMPLIANT FALL PROTECTION | LF | 500 | $ - 0 | $0.00 | 10 | $ - 0 | $ - 0 |
| CAGE ON EXISTING VERTICAL ROOF ACCESS | | | | | | | |
| LADDERS | | | | | | | |
| 0035AE | INSTALL NEW FIXED, ROOF ACCESS LADDER | LF | 500 | $ - 0 | $0.00 | 100 | $ - 0 | $ - 0 |
| ALUMINUM | | | | | | | |
| 0035AF | INSTALL NEW FIXED, ROOF ACCESS LADDER | LF | 500 | $ - 0 | $0.00 | 100 | $ - 0 | $ - 0 |
| STEEL | | | | | | | |
| 0035AG | PROCURE AND INSTALL NEW STAIRS (INCLUSIVE | Riser | 500 | $ - 0 | $0.00 | 10 | $ - 0 | $ - 0 |
| OF RISERS, TREADS AND SIDE RAILS FOR ACCESS | | | | | | | |
| TO ROOF MOUNTED EQUIPMENT/PENTHOUSES | | | | | | | |
| 3 FT WIDE, GRATED TREADS, 2 LINE PIPE RAIL | | | | | | | |
0036 ROOF SAFETY RAIL SYSTEMS
| 0036AA | POST, PERMANENT RAIL SYSTEM, STEEL TUBE | EA | 250 | $ - 0 | $0.00 | 25 | $ - 0 | $ - 0 |
| POWDER COATED SAFETY YELLOW, WALL | | | | | | | |
| MOUNT, MASONRY WALL (BRICK), 42 INCH HGT | | | | | | | |
| 0036AB | POST, PERMANENT RAIL SYSTEM, STEEL TUBE | EA | 250 | $ - 0 | $0.00 | 25 | $ - 0 | $ - 0 |
| POWDER COATED SAFETY YELLOW, WALL | | | | | | | |
| MOUNT, MASONRY WALL (CMU), 42 INCH HGT | | | | | | | |
| 0036AC | POST, PERMANENT RAIL SYSTEM, STEEL TUBE | EA | 250 | $ - 0 | $0.00 | 25 | $ - 0 | $ - 0 |
| POWDER COATED SAFETY YELLOW, WALL | | | | | | | |
| MOUNT, CONCRETE WALL, 42 INCH HGT | | | | | | | |
| 0036AD | POST, PERMANENT RAIL SYSTEM, STEEL TUBE | EA | 250 | $ - 0 | $0.00 | 25 | $ - 0 | $ - 0 |
| POWDER COATED SAFETY YELLOW, PARAPET | | | | | | | |
| MOUNT, BRICK PARAPET, 15-30 INCH POST HGT | | | | | | | |
| 0036AE | POST, PERMANENT RAIL SYSTEM, STEEL TUBE | EA | 250 | $ - 0 | $0.00 | 25 | $ - 0 | $ - 0 |
| POWDER COATED SAFETY YELLOW,PARAPET | | | | | | | |
| MOUNT, BRICK PARAPET, 31-42 INCH POST HGT | | | | | | | |
| 0036AF | POST, PERMANENT RAIL SYSTEM, STEEL TUBE | EA | 250 | $ - 0 | $0.00 | 25 | $ - 0 | $ - 0 |
| POWDER COATED SAFETY YELLOW, PARAPET | | | | | | | |
| MOUNT, CMU PARAPET, 15-30 INCH POST HGT | | | | | | | |
| 0036AG | POST, PERMANENT RAIL SYSTEM, STEEL TUBE | EA | 250 | $ - 0 | $0.00 | 25 | $ - 0 | $ - 0 |
| POWDER COATED SAFETY YELLOW, PARAPET | | | | | | | |
| MOUNT, CMU PARAPET, 31-42 INCH POST HGT | | | | | | | |
| 0036AH | POST, PERMANENT RAIL SYSTEM, STEEL TUBE | EA | 250 | $ - 0 | $0.00 | 25 | $ - 0 | $ - 0 |
| POWDER COATED SAFETY YELLOW, PARAPET | | | | | | | |
| MOUNT, CONCRETE PARAPET, 15-30 INCH POST | | | | | | | |
| HEIGHT | | | | | | | |
| 0036AI | POST, PERMANENT RAIL SYSTEM, STEEL TUBE | EA | 250 | $ - 0 | $0.00 | 25 | $ - 0 | $ - 0 |
| POWDER COATED SAFETY YELLOW, PARAPET | | | | | | | |
| MOUNT, CONCRETE PARAPET, 31-42 INCH POST | | | | | | | |
| HEIGHT | | | | | | | |
| 0036AJ | BASE PLATE FOR NON-PENETRATING SAFETY | EA | 250 | $ - 0 | $0.00 | 25 | $ - 0 | $ - 0 |
| RAIL SYSTEM | | | | | | | |
| 0036AK | POST FOR BASE PLATES, STEEL POWDER COATED | EA | 250 | $ - 0 | $0.00 | 25 | $ - 0 | $ - 0 |
| SAFETY YELLOW, 42 INCH HGT | | | | | | | |
| 0036AL | TOP AND MID RAILS, STEEL POWDER COATED | PR | 250 | $ - 0 | $0.00 | 25 | $ - 0 | $ - 0 |
| SAFETY YELLOW, 10 FT FIXED LENGTH | | | | | | | |
| 0036AM | TOP AND MID RAILS, STEEL POWDER COATED | PR | 250 | $ - 0 | $0.00 | 25 | $ - 0 | $ - 0 |
| SAFETY YELLOW, 8 FT FIXED LENGTH | | | | | | | |
| 0036AN | TOP AND MID RAILS, STEEL POWDER COATED | PR | 250 | $ - 0 | $0.00 | 25 | $ - 0 | $ - 0 |
| SAFETY YELLOW, ADJUSTABLE LENGTH 70-43 | | | | | | | |
| INCHES | | | | | | | |
| 0036AO | TOP AND MID RAILS, STEEL POWDER COATED | PR | 250 | $ - 0 | $0.00 | 25 | $ - 0 | $ - 0 |
| SAFETY YELLOW, ADJUSTABLE LENGTH 43-29 | | | | | | | |
| INCHES | | | | | | | |
| 0036AP | OUTSIDE CORNER RAILS, 20.5 INCH O.C., POWDER | EA | 125 | $ - 0 | $0.00 | 15 | $ - 0 | $ - 0 |
| COATED STEEL, SAFETY YELLOW | | | | | | | |
| 0036AQ | INSIDE CORNER RAILS, 12.5 INCH O.C, POWDER | EA | 125 | $ - 0 | $0.00 | 15 | $ - 0 | $ - 0 |
| COATED STEEL, SAFETY YELLOW. | | | | | | | |
| TOTAL | $0.00 | TOTAL | $ - 0 |
| TOTAL AMOUNT BASED ON A 5 YEAR CONTRACT WITHOUT ESCALATION FOR CLIN 0001 - APG NORTH AND SOUTH | $0.00 | | |
| AVERAGE BASE YEAR (YEAR 1) WITHOUT ESCALATION FOR CLIN 0001 - APG NORTH AND SOUTH | $0.00 | | |
| TOTAL AMOUNT BASED ON A 5 YEAR BASE WITHOUT ESCALATION FOR CLIN 0002 - ALC | $0.00 | | |
| AVERAGE BASE YEAR (YEAR 1) WITHOUT ESCALATION FOR CLIN 0002 - ALC | $0.00 | | |
6 Month Extension Pricing
| 6 Month Extension Pricing | | | |
| | INSTRUCTIONS: This pricing is for the North/South Cantonment comprises the physical area of Aberdeen Proving Ground and the Former Edgewood arsenal area. The Churchville Automotive test facility, Grace’s quarters and Carrol Island areas all fall with the region which is included in the Davis Bacon wage determinations for Aberdeen/Edgewood Areas. Please include the base unit price in column E and it will automatically calculate the total price in column F. Add the percentage escalation in the Pricing Summary tab only. | INSTRUCTIONS: This pricing is for the Adelphi Laboratory Center area as it falls within a different zone relative to the Davis Bacon wage determinations. Please include the co-efficient in cel H9 as a number (i.e., 1.21; 0.97; etc.) and it will automatically calculate the unit price in column H and the total price in column I. |
| 0000 | SUBCLINS 0001-0036 | | |
| SF/IN=Square Foot Per Inch Of Thickness |
| VLF = Vertical Linear Feet |
| ITEM NO. | SUPPLIES/SERVICES | UNIT | ESTIMATED 6 MONTH QUANTITY | UNIT PRICE WITHOUT ESCALATION | TOTAL | ESTIMATED QUANTITY FOR ALC | ALC COEFFICIENT | ALC TOTAL |
| | | | | | | 0 | |
| 0001 | ASBESTOS ROOFING | | | | | | | |
| 0001AA | REMOVE AND DISPOSE OF NON-FRIABLE | SF | 2500 | $ - 0 | $0.00 | 50 | $ - 0 | $ - 0 |
| ASBESTOS SHINGLE ROOFING AND FELTS | | | | | | | |
| (ONE LAYER OF SHINGLES) | | | | | | | |
| 0001AB | REMOVE AND DISPOSE OF NON-FRIABLE | SF | 2000 | $ - 0 | $0.00 | 50 | $ - 0 | $ - 0 |
| ASBESTOS ROLL ROOFING | | | | | | | |
| 0001AC | REMOVE AND DISPOSE OF NON-FRIABLE | SF | 4000 | $ - 0 | $0.00 | 50 | $ - 0 | $ - 0 |
| ASBESTOS CONTAINING BASE FLASHING/CURB | | | | | | | |
| FLASHING | | | | | | | |
| 0001AD | REMOVE AND DISPOSE OF FRIABLE OR | SF | 12500 | $ - 0 | $0.00 | 50 | $ - 0 | $ - 0 |
| NON-FRIABLE ASBESTOS CORRUGATED | | | | | | | |
| FIBER REINFORCED CEMENT ROOF PANELS | | | | | | | |
| 0001AE | TRANSITE REMOVAL (WALLS, CEILINGS, | SF | 1000 | $ - 0 | $0.00 | 20 | $ - 0 | $ - 0 |
| SOFFITS) COMPLY WITH ALL FEDERAL AND | | | | | | | |
| STATE REGULATIONS >0' UP TO 10' | | | | | | | |
| 0001AF | TRANSITE REMOVAL (WALLS, CEILINGS, | SF | 1000 | $ - 0 | $0.00 | 20 | $ - 0 | $ - 0 |
| SOFFITS) COMPLY WITH ALL FEDERAL AND | | | | | | | |
| STATE REGULATIONS >10' UP TO 20' | | | | | | | |
0002 ASPHALT ROOFING
| 0002AA | REMOVE AND DISPOSE OF ASPHALT | SF | 25000 | $ - 0 | $0.00 | 7500 | $ - 0 | $ - 0 |
| SHINGLE ROOFING AND FELT UNDERLAYMENT | | | | | | | |
| (ONE LAYER OF SHINGLES) | | | | | | | |
0002AB REPLACE INDIVIDUAL ASPHALT SHINGLE EA 150 $ - 0 $0.00 20 $ - 0 $ - 0
| 0002AC | RENAIL SHEATHING AND INSTALL | SF | 12500 | $ - 0 | $0.00 | 2000 | $ - 0 | $ - 0 |
| ASPHALT SHINGLE ROOFING, 30 LB FELT | | | | | | | |
| AND 25 YEAR ASPHALT SHINGLES ON ALL | | | | | | | |
| SLOPES | | | | | | | |
| 0002AD | RENAIL SHEATHING AND INSTALL | SF | 25000 | $ - 0 | $0.00 | 7500 | $ - 0 | $ - 0 |
| ASPHALT SHINGLE ROOFING, 30 LB FELT | | | | | | | |
| AND 40 YEAR ASPHALT SHINGLES ON ALL | | | | | | | |
| SLOPES | | | | | | | |
| 0002AE | INSTALL AN ADDITIONAL PLY OF THIRTY POUND | SF | 25000 | $ - 0 | $0.00 | 7500 | $ - 0 | $ - 0 |
| ROOFING FELT, ALL SLOPES | | | | | | | |
| 0002AF | INSTALL A SINGLE LAYER OF SYNTHETIC FIBER | SF | 20000 | $ - 0 | $0.00 | 5000 | $ - 0 | $ - 0 |
| ROOFING FELT, ALL SLOPES | | | | | | | |
| 0002AG | INSTALL AN ADDITIONAL LAYER OF SYNTHETIC | SF | 2500 | $ - 0 | $0.00 | 500 | $ - 0 | $ - 0 |
| FIBER ROOFING FELT, ALL SLOPES | | | | | | | |
| 0002AH | REMOVE AND DISPOSE OF ASPHALT | SF | 1750 | $ - 0 | $0.00 | 50 | $ - 0 | $ - 0 |
| ROLL ROOFING AND UNDERLAYMENTS | | | | | | | |
| 0002AI | RENAIL SHEATHING AND INSTALL DOUBLE | SF | 1750 | $ - 0 | $0.00 | 50 | $ - 0 | $ - 0 |
| COVERAGE ASPHALT ROLL ROOFING | | | | | | | |
| AND UNDERLAYMENTS | | | | | | | |
0003 BUILT UP AND IRMA ROOF SYSTEMS
| 0003AA | REMOVE AND DISPOSE OF LIGHT WEIGHT | SF/IN | 3750 | $ - 0 | $0.00 | 200 | $ - 0 | $ - 0 |
| GYPSUM MATERIAL | | | | | | | |
| 0003AB | REMOVE AND DISPOSE OF BUILT UP | SF | 50000 | $ - 0 | $0.00 | 5000 | $ - 0 | $ - 0 |
| ROOFING, ASPHALT | | | | | | | |
| 0003AC | REMOVE AND DISPOSE OF BUILT UP | SF | 50000 | $ - 0 | $0.00 | 5000 | $ - 0 | $ - 0 |
| ROOFING, COAL TAR | | | | | | | |
| 0003AD | REMOVE AND SALVAGE GRAVEL BALLAST, APPLY | SF | 50000 | $ - 0 | $0.00 | 5000 | $ - 0 | $ - 0 |
| FLOOD COAT OF HOT ASPHALT TO ROOF | | | | | | | |
| SURFACE, COVER WITH SALVAGED GRAVEL | | | | | | | |
| 0003AE | REMOVE AND DISPOSE OF GRAVEL BALLAST | SF | 50000 | $ - 0 | $0.00 | 5000 | $ - 0 | $ - 0 |
| APPLY FLOOD COAT OF HOT ASPHALT TO ROOF | | | | | | | |
| SURFACE, COVER WITH NEW GRAVEL | | | | | | | |
| 0003AF | REMOVE GRAVEL, APPLY FLOOD COAT OF HOT | SF | 50000 | $ - 0 | $0.00 | 5000 | $ - 0 | $ - 0 |
| ASPHALT AND NEW PLY OF ROOFING MEMBRANE | | | | | | | |
| SET IN HOT ASPHALT, COVER WITH GRAVEL | | | | | | | |
| BALLAST | | | | | | | |
| 0003AG | REMOVE, SALVAGE AND REINSTALL ROCK | SF | 25000 | $ - 0 | $0.00 | 2500 | $ - 0 | $ - 0 |
| BALLAST FROM ROOF SURFACE | | | | | | | |
| 0003AH | REMOVE, SALVAGE AND REINSTALL EXISTING | SF | 25000 | $ - 0 | $0.00 | 2500 | $ - 0 | $ - 0 |
| EPS BOARD INSULATION MATERIALS | | | | | | | |
| 0003AI | REMOVE AND DISPOSE OF THE EXISTING ROOF | SF | 25000 | $ - 0 | $0.00 | 2500 | $ - 0 | $ - 0 |
| MEMBRANE AND PROTECTION MAT FROM | | | | | | | |
| CONCRETE ROOF DECK | | | | | | | |
| 0003AJ | REMOVE AND DISPOSE OF THE EXISTING ROOF | SF | 25000 | $ - 0 | $0.00 | 2500 | $ - 0 | $ - 0 |
| MEMBRANE, PROTECTION MAT AND GYPSUM | | | | | | | |
| BOARD FROM STEEL ROOF DECK | | | | | | | |
| 0003AK | INSTALL NEW RUBBERIZED ASPHALT ROOFING | SF | 25000 | $ - 0 | $0.00 | 2500 | $ - 0 | $ - 0 |
| SYSTEM AND PROTECTION MAT USING | | | | | | | |
| MATERIALS COMPATIBLE WITH EXISTING ROOF | | | | | | | |
| SYSTEM | | | | | | | |
| 0003AL | INSTALL NEW 1/2 INCH THICK CEMENT BOARD | SF | 25000 | $ - 0 | $0.00 | 2500 | $ - 0 | $ - 0 |
| TO STEEL ROOFING DECK | | | | | | | |
| 0003AM | INSTALL NEW COLD APPLIED SBS MEMBRANE | SF | 25000 | $ - 0 | $0.00 | 2500 | $ - 0 | $ - 0 |
| PROTECTION COURSE OVER ROOF MEMBRANE | | | | | | | |
| 0003AN | INSTALL NEW DRAINAGE MAT AND GEOTEXTILE | SF | 25000 | $ - 0 | $0.00 | 2500 | $ - 0 | $ - 0 |
| FABRIC | | | | | | | |
0004 MODIFIED BITUMEN
| 0004AA | REMOVE AND DISPOSE OF BUILT UP | SF | 125000 | $ - 0 | $0.00 | 75000 | $ - 0 | $ - 0 |
| ROOFING, MODIFIED BITUMEN | | | | | | | |
| 0004AB | INSTALL 150 MIL., SBS BASE AND SBS CAP | SF | 22500 | $ - 0 | $0.00 | 50000 | $ - 0 | $ - 0 |
| FULLY ADHERED WITH TORCH WELDING | | | | | | | |
| MODIFIED BITUMEN ROOFING SYSTEM, | | | | | | | |
| FOR FIFTEEN YEAR WARRANTY, IN | | | | | | | |
| ACCORDANCE WITH MFG'S RECOMMEND- | | | | | | | |
| ATION | | | | | | | |
| 0004AC | INSTALL FULLY ADHERED TORCH APPLIED | SF | 125000 | $ - 0 | $0.00 | 75000 | $ - 0 | $ - 0 |
| APP 180 MIL BASE AND GRANULAR COATED | | | | | | | |
| CAP SHEET WITH A FIFTEEN YEAR | | | | | | | |
| WARRANTY, IN ACCORDANCE WITH THE | | | | | | | |
| MANUFACTURER'S RECOMMENDATION | | | | | | | |
| 0004AD | INSTALL A FULLY ADHERED, COLD APPLIED | SF | 12500 | $ - 0 | $0.00 | 7500 | $ - 0 | $ - 0 |
| SBS 150 MOD. BIT. ROOFING SYSTEM | | | | | | | |
| CONSISTING OF AN SBS 150 BASE AND CAP | | | | | | | |
| SHEET IN ACCORDANCE WITH THE | | | | | | | |
| MANUFACTURER'S REQUIRMENTS | | | | | | | |
| 0004AE | INSTALL A FULLY ADHERED, COLD APPLIED | SF | 125000 | $ - 0 | $0.00 | 75000 | $ - 0 | $ - 0 |
| APP180 MOD. BIT. ROOFING SYSTEM | | | | | | | |
| CONSISTING OF AN APP 180 BASE AND CAP | | | | | | | |
| SHEET IN ACCORDANCE WITH THE | | | | | | | |
| MANUFACTURER'S REQUIREMENTS | | | | | | | |
0004AF INSTALL AN SBS 150 INTERPLY SHEET SF 13000 $ - 0 $0.00 10000 $ - 0 $ - 0
0004AG INSTALL AN APP 180 INTERPLY SHEET SF 22000 $ - 0 $0.00 15000 $ - 0 $ - 0
| 0004AH | INSTALL A WHITE BUTYL ELASTOMERIC | SF | 100000 | $ - 0 | $0.00 | 5000 | $ - 0 | $ - 0 |
| ROOF COATING FORMULATED FOR USE ON MOD | | | | | | | |
| BIT ROOFS SYSTEMS PER MANUFACTURERS | | | | | | | |
| INSTALLATION AND TEN YEAR WARRANTY | | | | | | | |
| REQUIREMENTS | | | | | | | |
| 0004AJ | INSTALL ASPHALT BASE, FIBERED | SF | 62500 | $ - 0 | $0.00 | 5000 | $ - 0 | $ - 0 |
| ALUMINUM COATING | | | | | | | |
0004AK REPAIR MODIFIED BITUMEN SEAMS LF 2500 $ - 0 $0.00 500 $ - 0 $ - 0
0004AL PATCH MODIFIED BITUMEN ROOFING SF 2500 $ - 0 $0.00 500 $ - 0 $ - 0
| 0004AM | INSTALL MODIFIED BITUMEN BASE | SF | 15000 | $ - 0 | $0.00 | 2500 | $ - 0 | $ - 0 |
| FLASHING | | | | | | | |
| 0004AN | INSTALL MODIFIED BITUMEN CURB | SF | 15000 | $ - 0 | $0.00 | 2500 | $ - 0 | $ - 0 |
| FLASHING | | | | | | | |
0004AP INSTALL PITCH POCKET->0 UP TO 50 SQ IN EA 10 $ - 0 $0.00 5 $ - 0 $ - 0
0004AQ INSTALL PITCH POCKET->50 UP TO 300 SQ IN EA 138 $ - 0 $0.00 18 $ - 0 $ - 0
0005 METAL ROOFING AND WALL PANELS
0005AA REMOVE AND DISPOSE OF METAL ROOFING SF 12500 $ - 0 $0.00 4500 $ - 0 $ - 0
0005AB INSTALL COPPER SHEET ROOFING SF 600 $ - 0 $0.00 0 $ - 0 $ - 0
| 0005AC | INSTALL PLAIN PANEL METAL (STEEL) | SF | 100 | $ - 0 | $0.00 | 500 | $ - 0 | $ - 0 |
| ROOFING | | | | | | | |
| 0005AD | INSTALL PLAIN PANEL METAL (ALUMINUM) | SF | 100 | $ - 0 | $0.00 | 500 | $ - 0 | $ - 0 |
| ROOFING | | | | | | | |
| 0005AE | INSTALL FACTORY FINISHED PANEL | SF | 12500 | $ - 0 | $0.00 | 2500 | $ - 0 | $ - 0 |
| METAL (STEEL) ROOFING STANDARD | | | | | | | |
| COLORS | | | | | | | |
| 0005AF | INSTALL FACTORY FINISHED PANEL | SF | 12500 | $ - 0 | $0.00 | 2500 | $ - 0 | $ - 0 |
| METAL (ALUMINUM) ROOFING STANDARD | | | | | | | |
| COLORS | | | | | | | |
| 0005AG | INSTALL FACTORY FINSHED METAL WALL | SF | 12500 | $ - 0 | $0.00 | 2500 | $ - 0 | $ - 0 |
| PANEL (STEEL) STANDARD MANUFACTURER | | | | | | | |
| COLORS, NON-INSULATED PANEL | | | | | | | |
| 0005AH | INSTALL FACTORY FINISHED METAL WALL | SF | 12500 | $ - 0 | $0.00 | 2500 | $ - 0 | $ - 0 |
| PANEL (ALUMINUM) STANDARD MANUFACTURER | | | | | | | |
| COLORS, NON-INSULATED PANEL | | | | | | | |
| 0005AI | INSTALL NEW METAL HAT CHANNEL, 1.25 | LF | 425 | $ - 0 | $0.00 | 50 | $ - 0 | $ - 0 |
| INCHES DEEP | | | | | | | |
| 0005AJ | INSTALL NEW METAL HAT CHANNEL 1.5 | LF | 625 | $ - 0 | $0.00 | 50 | $ - 0 | $ - 0 |
| INCHES DEEP | | | | | | | |
| 0005AK | INSTALL NEW TRANSULCENT POLYCARBONATE | SF | 10000 | $ - 0 | $0.00 | 0 | $ - 0 | $ - 0 |
| HONEYCOMB STYLE WALL PANELS IN ALUMINUM | | | | | | | |
| FRAME, 1.5 INCHES IN THICKNESS TO CLERESTORY | | | | | | | |
| (EXTECH SERIES 3440 OR APPROVED EQUIVALENT | | | | | | | |
0006 SLATE ROOFING
| 0006AA | REMOVE AND DISPOSE SLATE ROOFING | SF | 7500 | $ - 0 | $0.00 | 0 | $ - 0 | $ - 0 |
| AND FELT UNDERLAYMENT | | | | | | | |
| 0006AB | REPLACE INDIVIDUAL BROKEN SLATE | EA | 25 | $ - 0 | $0.00 | 0 | $ - 0 | $ - 0 |
| SHINGLES | | | | | | | |
| 0006AC | REPLACE INDIVIDUAL BROKEN SLATE | EA | 5 | $ - 0 | $0.00 | 0 | $ - 0 | $ - 0 |
| SHINGLES WITH GOVERNMENT SUPPLIED | | | | | | | |
| SLATE SHINGLES | | | | | | | |
| 0006AD | RENAIL SHEATHING, INSTALL 30 LB FELT, | SF | 1000 | $ - 0 | $0.00 | 0 | $ - 0 | $ - 0 |
| INSTALL MANUFACTURED SLATE (NON- | | | | | | | |
| ASBESTOS FIBER CEMENT) SHINGLES | | | | | | | |
| 0006AE | RENAIL SHEATHING AND INSTALL NATURAL | SF | 7500 | $ - 0 | $0.00 | 0 | $ - 0 | $ - 0 |
| SLATE ROOOFING AND 30 LB FELT | | | | | | | |
| 0007 | CORRUGATED FIBER REINFORCED |
| CEMENT ROOF DECKING (NON-ASBESTOS) |
| 0007AA | REMOVE AND DISPOSE OF INSTALLED | SF | 1250 | $ - 0 | $0.00 | 50 | $ - 0 | $ - 0 |
| CORRUGATED FIBER REINFORCED | | | | | | | |
| CEMENT ROOF DECKING > 2" thick | | | | | | | |
0008 SINGLE PLY ROOFING EPDM ROOFING
0008AA REMOVE EPDM ROOFING SF 52500 $ - 0 $0.00 7500 $ - 0 $ - 0
| 0008AB | REMOVE AND DISPOSE OF CONCRETE PAVER | SF | 700 | $ - 0 | $0.00 | 500 | $ - 0 | $ - 0 |
| BALLAST FROM EPDM ROOF SYSTEMS | | | | | | | |
| 0008AC | REMOVE AND DISPOSE OF RIVER ROCK BALLAST | SF | 700 | $ - 0 | $0.00 | 500 | $ - 0 | $ - 0 |
| FROM LOOSE LAID, GRAVEL BALLASTED EPDM | | | | | | | |
| ROOF SYSTEMS | | | | | | | |
| 008AD | INSTALL FULLY ADHERED EPDM | SF | 700 | $ - 0 | $0.00 | 500 | $ - 0 | $ - 0 |
| ROOFING SYSTEM, INCLUDING BASE AND | | | | | | | |
| STRIP FLASHING,FASTENERS AND ADHESIVE | | | | | | | |
| 0008AE | INSTALL EPDM ROOFING SYSTEM WITH | SF | 700 | $ - 0 | $0.00 | 500 | $ - 0 | $ - 0 |
| CONCRETE ROOF PAVER BALLAST, BASE | | | | | | | |
| STRIP AND PERFORATED EDGE FLASHING | | | | | | | |
0008AF REPAIR EPDM SEAMS LF 75 $ - 0 $0.00 75 $ - 0 $ - 0
0008AG PATCH EPDM ROOFING SF 20 $ - 0 $0.00 20 $ - 0 $ - 0
0009 ROOF COATING SYSTEMS
| 0009AA | INSTALL FLUID APPLIED ELASTOMERIC | SF | 15000 | $ - 0 | $0.00 | 7500 | $ - 0 | $ - 0 |
| ROOFING PRIMER, COVERED WITH THREE | | | | | | | |
| (3) COATS ELASTOMERIC ACRYLIC ROOF | | | | | | | |
| COATING ON EPDM ROOF SYSTEMS TO INCLUDE | | | | | | | |
| COVERING SEAMS WITH REINFORCING FABRIC | | | | | | | |
| 0009AB | INSTALL "SEAL-O-FLEX" ELASTOMERIC | SF | 16000 | $ - 0 | $0.00 | 4500 | $ - 0 | $ - 0 |
| WATERPROOFING SYSTEM CONSISTING OF | | | | | | | |
| THREE PART SYSTEM WITH CLOTH REINFORCING | | | | | | | |
| 0009AC | INSTALL A THREE PART HYBRID URETHANE/ | SF | 25000 | $ - 0 | $0.00 | 4000 | $ - 0 | $ - 0 |
| ELASTOMERIC ROOF COATING SYSTEM TO | | | | | | | |
| INCLUDE FABRIC PLUS THREE COATS | | | | | | | |
| 0009AD | INSTALL A POLYMETHYLMETHACRYLATE | SF | 25000 | $ - 0 | $0.00 | 4000 | $ - 0 | $ - 0 |
| (PMMA) ROOF COATING SYSTEM OVER A | | | | | | | |
| STRUCTURAL CONCRETE DECK CONSISTING OF | | | | | | | |
| THREE PARTS TO INCLUDE FABRIC | | | | | | | |
| 0009AE | INSTALL A POLYMETHYLMETHACRYLATE | SF | 25000 | $ - 0 | $0.00 | 4000 | $ - 0 | $ - 0 |
| (PMMA) ROOF COATING SYSTEM OVER A LIGHT | | | | | | | |
| WEIGHT CONCRETE DECK CONSISTING OF A ONE | | | | | | | |
| INCH LAYER OF ROCK WOOL INSULATION WITH | | | | | | | |
| SBS MODIFIED BITUMEN COVER BOARD SET IN | | | | | | | |
| LOW RISE ADHESIVE FOLLOWED BY THE THREE | | | | | | | |
| PART SYSTEM INCLUSIVE OF FABRIC | | | | | | | |
| 0009AF | INSTALL PMMA FLASHING TO CURBS, ROOF | SF | 25000 | $ - 0 | $0.00 | 2000 | $ - 0 | $ - 0 |
| PENETRATIONS AND PARAPET WALLS IAW | | | | | | | |
| MANUFACTURER'S REQUIREMENTS | | | | | | | |
0010 THERMOPOLYOLEFIN (TPO) ROOFING
0010AA REMOVE AND DISPOSE OF TPO ROOFING SYSTEM SF 7500 $ - 0 $0.00 1500 $ - 0 $ - 0
| 0010AB | INSTALL A FULLY ADHERED, FLEECE BACKED | SF | 25000 | $ - 0 | $0.00 | 7500 | $ - 0 | $ - 0 |
| POLYESTER SCRIM REINFORCED TPO MEMBRANE | | | | | | | |
| WITH A NOMINAL THICKNESS OF 060 INCHES | | | | | | | |
| (TPO THICKNESS) | | | | | | | |
| 1010AC | INSTALL HOOK AND LOOP (VELCRO FASTENED) | SF | 25000 | $ - 0 | $0.00 | 1500 | $ - 0 | $ - 0 |
| FLEECE BACKED 115 MIL TPO ROOF SYSTEM | | | | | | | |
| (RapidLock Membrane and Insulation or approved | | | | | | | |
| Equivalent) | | | | | | | |
| 0010AC | INSTALL FULLY ADHERED FLEECE BACKED | SF | 6000 | $ - 0 | $0.00 | 1500 | $ - 0 | $ - 0 |
| TPO FLASHING 0.060 INCH THICKNESS | | | | | | | |
| 0010AD | INSTALL TPO VENT PIPE FLASHING, UP TO 3 | EA | 12 | $ - 0 | $0.00 | 10 | $ - 0 | $ - 0 |
| INCHES IN DIAMETER | | | | | | | |
| 0010AE | INSTALL TPO VENT PIPE FLASHING, FROM 3.1 | EA | 22 | $ - 0 | $0.00 | 10 | $ - 0 | $ - 0 |
| INCHES IN DIAMTER AND LARGER | | | | | | | |
0010AF REPAIR TPO/PVC MEMBRANE SEAMS LF 2625 $ - 0 $0.00 600 $ - 0 $ - 0
0010AG PATCH TPO/PVC ROOFING SF 3750 $ - 0 $0.00 300 $ - 0 $ - 0
| 0010AH | INSTALL FULLY ADHERED 12 INCH WIDE | LF | 800 | $ - 0 | $0.00 | 30 | $ - 0 | $ - 0 |
| PERIMETER WARNING TAPE TEN FEET FROM | | | | | | | |
| ROOF EDGE | | | | | | | |
0011 ROOF WALKS
| 0011AA | INSTALL COMPOSITION TYPE TRAFFIC | SF | 500 | $ - 0 | $0.00 | 50 | $ - 0 | $ - 0 |
| SURFACE (MINERAL SURFACE ASPHALT | | | | | | | |
| PLANK) FOR BUILT UP ROOFS | | | | | | | |
| 0011AB | INSTALL ADDITIONAL PLY OF TORCHED | SF | 1100 | $ - 0 | $0.00 | 300 | $ - 0 | $ - 0 |
| APPLIED MODIFIED BITUMEN CAP SHEET | | | | | | | |
| WITH CONTRASTING GRANULAR COATING | | | | | | | |
| TO MODIFIED BITUMEN ROOFING SYSTEM | | | | | | | |
| 0011AC | INSTALL ADDITIONAL PLY OF COLD APPLIED | SF | 1100 | $ - 0 | $0.00 | 300 | $ - 0 | $ - 0 |
| MODIFIED BITUMEN CAP SHEET WITH | | | | | | | |
| CONTRASTING GRANULAR COATING TO | | | | | | | |
| MODIFIED BITUMEN ROOFING SYSTEM | | | | | | | |
| 0011AD | INSTALL FULLY ADHERED, TPO COMPATIBLE | SF | 1750 | $ - 0 | $0.00 | 500 | $ - 0 | $ - 0 |
| FLEXIBLE WALK PATH WITH EMBOSSED | | | | | | | |
| DIAMOND PLATE TREAD DESIGN OF A | | | | | | | |
| CONTRASTING COLOR AND HIGH VISIBILITY | | | | | | | |