This engineering change proposal and associated notices of revision concern modifications to technical drawings and part lists for expandable ISO shelters. The changes make several shelter components optional, including closeout panels, environmental control unit access panels, cargo stowage channels, and manuals. The proposal aims to reduce costs for a long-term customer by eliminating seldom-used elements. Revisions to the drawings and part listings specify configuration details for variants with and without the optional components.

The pre-solicitation notice involves a planned requirements contract for two models of Army Standard Family ISO shelters with 60 or 100 amp electrical service. The contract would have a two-year base period and three one-year options for a total of five years. The solicitation seeks to award a single best value contract on a full and open competitive basis to provide fabricated shelters.

Attachment 0006

View the file

Other files

File Type Posted
W56HZV-18-R-0057_Conformed_Copy_14_JUN_2018.pdf PDF
W56HZV-18-R-0057_AMD_0004.pdf PDF
QAs_(3)_for_ISO_Shelter.pdf PDF
Attachment_0020_Pricing_Attachment.xlsx XLSX spreadsheet
Attachment_0002_SOW_for_ISO_Two-sided_Shelter_TM_-13&P-20180523.docx DOCX document
W56HZV18R0057-0003.pdf PDF
Attachment_0005_TWO_SIDED_Provisioning_SOW_7_June__2018.doc DOC document
Attachment_0001_SOW_for_ISO_One-Sided_Shelter_TM_-13&P-20180523.docx DOCX document
Attachment_0007_SOW_for_MERWS_TM_-13&P_20180523.docx DOCX document
Attachment_0004_One_Sided_SIDED_Provisioning_SOW_7_June__2018.doc DOC document
Attachment_0020_Pricing_Attachment.xlsx XLSX spreadsheet
Q&As_(2).pdf PDF
W56HZV18R0057-0002.pdf PDF
Q&As_(1).pdf PDF
W56HZV18R0057-0001.pdf PDF
Attachment_0010_Camouflage_Pattern,_ISO_One_Side_Exp.pdf PDF
CDRLs.zip ZIP file
Attachment_0011_Camouflage_Pattern,_ISO_Two_Side_Exp.pdf PDF
Attachment_0007_SOW_for_MERWS_TM_-13&P_20180312_HLD.DOCX DOCX document
W56HZV18R0057.pdf PDF
Attachment_0004_One_Sided_SIDED_Provisioning_SOW_5_March_2018_FINAL_(003....doc DOC document
Attachment_0001_SOW_for_ISO_One-Sided_Shelter_TM_-13&P-20180315_HLD.DOCX DOCX document
Attachment_0003_ISO_Shelter_Exp_One_Side,_Two_Side_PKG_SOW.DOCX DOCX document
Attachment_0020_Pricing_Attachment.xlsx XLSX spreadsheet
Attachment_0012_TDPL_5-4-2828_One_Side_Exp_60_amp.zip ZIP file
Attachment_0023_SBP-Certification-Subcontractor.docx DOCX document
Attachment_0002_SOW_for_ISO_Two-sided_Shelter_TM_-13&P-20180315_HLD.DOCX DOCX document
Attachment_0009_MTA_Supportability_Analysis_MERWS_14_APRIL_2017.docx DOCX document
Attachment_0015_TDPL_5-4-3201_Two_Side_Exp_100_amp.zip ZIP file
Attachment_0021_SBP-Workbook.xlsx XLSX spreadsheet
Attachment_0013_TDPL_5-4-3200_One_Side_Exp_100_amp.zip ZIP file
Attachment_0024_First-Article-Waiver-Worksheet.pdf PDF
Attachment_0008_MERWS__Provisioning_SOW_5_March_2018_FINAL_(003).doc DOC document
Attachment_0014_TDPL_5-4-3118_Two_Side_Exp_60_amp.zip ZIP file
Attachment_0022_SBP-WorkbookInstructions.docx DOCX document
Attachment_0005_TWO_SIDED_Provisioning_SOW_5_March_2018_FINAL_(003).doc DOC document
Attachment_0016_TDPL_17-2-1250_MERWS.zip ZIP file
Attachment_0019_PPQ.doc DOC document
Show all 38

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ENGINEERING CHANGE PROPOSAL

(SHORT FORM)

(See MIL-STD-481 for instructions)

DATE (YYYYMMDD)

20171106

Form Approved OMB No. 0704-0188

PROCURING ACTIVITY NUMBER

The public burden for this collection of information is estimated to average 2 hours per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing the burden, to Department of Defense, Washington Headquarters Services, Directorate for Information Operations and Reports (0704-0188), 1215 Jefferson Davis Highway, Suite 1204, Arlington, VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THIS ADDRESS.

1. ORIGINATOR NAME AND ADDRESS

MARK ALBANO

US ARMY NATICK SOLDIER RDEC

ROOM 238 MACGILLVARY HALL

NATICK, MA 01760

2. CONTRACT NUMBER AND LINE ITEM

3. PROCURING CONTRACTING OFFICER

CODE

TEL

4. TITLE OF CHANGE

OPTIONAL CLOSEOUT PANEL ASSEMBLIES

5. ECP NUMBER

REV

AMEND 6. CAGE CODE 7. CLASS OF ECP 8. JUST.CODE 9.PRIORITY

81337 I

10. SPECIFICATIONS AFFECTED 11. DRAWINGS AFFECTED

CAGE CODE

SPECIFICATION / DOCUMENT NO.

CAGE CODE

NUMBER

81337 5-4-3200 T

81337 PL 5-4-3200 R

(SEE SHEET 2)

12. CONFIGURATION ITEM NOMENCLATURE / TYPE DESIGNATION / WEAPON SYSTEM CODE

SHELTER ASSEMBLY ONE SIDE EXPANDABLE – 100 AMP

13. IN PRODUCTION

YES X

NO

14. LOWEST ASSEMBLY AFFECTED

NOMENCLATURE

PART NO.

NSN

FIXED FLOOR ASSY

FIXED ROOF ASSY

FIXED SIDEWALL ASSY

5-4-2829 5-4-2831 5-4-3134

15. DESCRIPTION OF CHANGE

THE FOLLOWING COMPONENTS OF THE SHELTER ASSEMBLY ONE SIDE EXPANDABLE – 100 AMP ARE MADE OPTIONAL:

THE THREE (3) CLOSEOUT PANEL ASSEMBLIES LOCATED ON THE TWO HINGED SIDEWALL ASSEMBLIES AND THE HINGED

SIDEWALL ASSEMBLY.

THE LOWER CLOSEOUT FRAME INSTALLATION AND CLOSEOUT PANEL ASSEMBLY LOCATED ON THE FIXED SIDEWALL.

THE ECU INTAKE AND ECU RETURN PANEL ASSEMBLIES STOWED ON THE FIXED ROOF.

THE FOUR (4) STOWAGE CHANNEL ASSEMBLIES LOCATED ON THE FIXED ROOF.

THE MANUAL HOLDER LOCATED NEXT TO THE PERSONNEL DOOR.

16. NEED FOR CHANGE

A LONG TERM CUSTOMER FOR THE SHELTER ASSEMBLY ONE SIDE EXPANDABLE – 100 AMP DOES NOT UTILIZE THE THREE CLOSEOUTS AND THE ADDITIONAL COMPONENTS LISTED ABOVE AND SEEKS TO MAKE THEM OPTIONAL IN ORDER TO

REDUCE THE OVERALL COST OF THE 2:1 ISO 100 AMP SHELTER.

17. EFFECT ON ASSOCIATED EQUIPMENT

18. PRODUCTION EFFECTIVITY BY SERIAL NUMBER

19. EFFECT ON PRODUCTION DELIVERY SCHEDULE

20. RECOMMENDED RETROFIT EFFECTIVITY

21. ESTIMATED KIT DELIVERY SCHEDULE

22. ESTIMATED COST/SAVINGS

23. SUBMITTING ACTIVITY AUTHORIZING SIGNATURE

23.a. TITLE

24. APPROVAL/DISAPPROVAL

a. RECOMMENDED

APPROVAL

DISAPPROVAL

b. APPROVAL

c. GOVERNMENT ACTIVITY

US ARMY NATICK SOLDIER RDEC

SIGNATURE

DATE (YYYYMMDD)

20171106 X

APPROVED

DISAPPROVED

d. APPROVAL

e. GOVERNMENT ACTIVITY

SIGNATURE

DATE (YYYYMMDD)

APPROVED

DISAPPROVED

DD FORM 1693, AUG 96 (EG)

PREVIOUS EDITION MAY BE USED. Designed using Microsoft Word, Dec 99

DD FORM 1693 (SHEET 2)

11. DRAWINGS AFFECTED (CONTINUED)

CAGE CODE NUMBER REV

81337 5-4-2829 K

81337 PL 5-4-2829 H

81337 5-4-2831 M

81337 PL 5-4-2831 K

81337 5-4-3134 F

81337 PL 5-4-3134 B

NOTICE OF REVISION (NOR)

THIS REVISION DESCRIBED BELOW HAS BEEN AUTHORIZED FOR THE DOCUMENT LISTED

1. DATE

(YYYYMMDD)

20171103

Form Approved

The public reporting burden for this collection of information is estimated to average 2 hours per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing the burden, to Department of Defense, Washington Headquarters Services, Directorate for Information Operations and Reports (0704-0188), 1215 Jefferson Davis Highway, Suite 1204, Arlington, VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number.

PLEASE DO NOT RETURN YOUR COMPLETED FORM TO THIS ADDRESS. RETURN COMPLETED FORM TO THE GOVERNMENT ISSUING CONTRACTING

OFFICER FOR THE CONTRACT/PROCURING ACTIVITY NUMBER LISTED IN ITEM 2 OF THIS FORM

2. PROCURING

ACTIVITY NO.

3. DODAAC

4. ORIGINATOR b. ADDRESS (Street, City, State, Zip Code)

ROOM 238 MACGILLVARY HALL

GEN GREENE AVE

NATICK, MA 01760

5. CAGE CODE

81337

6. NOR NO.

N01

a. TYPED NAME (First, Middle Initial, Last)

7. CAGE CODE

8. DOCUMENT NO.

5-4-3200

9. TITLE OF DOCUMENT

SHELTER ASSEMBLY - ONE SIDE EXPANDABLE - 100 AMP

10. REVISION LETTER 11. ECP NO.

a. CURRENT

T

b. NEW

U

12. CONFIGURATION ITEM (OR SYSTEM) TO WHICH ECP APPLIES

13. DESCRIPTION OF REVISION

1. SHEET 1, ADD NEW NOTE 30 TO READ “FIND NUMBER IS NOT PROVIDED IN THE 5-4-3200-2 VARIANT.”

2. SHEET 1 ZONE A5, ADD NOTATION TO READ “-2 NOT SHOWN.”

3. SHEET 2 LEFT SIDE VIEW, ADD NOTE 30 CALLOUT TO: FN9 AND FN11 IN ZONE E8 AND TO FN10 IN ZONE D6.

4. SHEET 2 LEFT SIDE VIEW, ADD FN 198 CALLOUT AND NOTE 30 CALLOUT TO FN51 IN ZONE D6.

5. SHEET 2 CARGO END VIEW, ADD NOTE 30 CALLOUT TO CLOSEOUT PANEL ASSEMBLY IN ZONE G4.

6. SHEET 2 PERSONNEL END VIEW, ADD NOTE 30 CALLOUT TO CLOSEOUT PANEL ASSEMBLY IN ZONE B4.

7. SHEET 2 PLAN VIEW, ADD FN 196 CALLOUT AND NOTE 30 CALLOUT TO FN2 IN ZONE E6.

8. SHEET 2 PLAN VIEW, ADD NOTE 30 CALLOUT TO FN9 AND FN11 IN ZONE D4.

9. SHEET 2 PLAN VIEW, ADD NOTE 30 CALLOUT TO FN9 AND FN10 IN ZONE C4.

10. SHEET 2 RIGHT SIDE VIEW, ADD FN 195 CALLOUT AND NOTE 30 CALLOUT TO FN1 IN ZONE E1.

11. SHEET 2 RIGHT SIDE VIEW, ADD NOTE 30 CALLOUT TO FN73 IN ZONE D1.

12. SHEET 2 RIGHT SIDE VIEW, ADD FN 199 CALLOUT AND NOTE 30 CALLOUT TO FN52 IN ZONE D1.

(CONTINUED ON SHEET 2)

14. THIS SECTION FOR GOVERNMENT USE ONLY

a. (X one) (1) Existing document supplemented by this NOR may be used in manufacture.

(2) Revised document must be received before manufacturer may incorporate this change.

(3) Custodian of master document shall make above revision and furnish revised document.

b. ACTIVITY AUTHORIZED TO APPROVE CHANGE FOR GOVERNMENT

US ARMY NATICK SOLDIER RDEC

c. TYPED NAME (First, Middle Initial, Last)

d. TITLE

e. SIGNATURE

f. DATE SIGNED

(YYYYMMDD)

15a. ACTIVITY ACCOMPLISHING REVISION

b. REVISION COMPLETED (Signature) c. DATE SIGNED

DD FORM 1695, AUG 96 (EG) PREVIOUS EDITION MAY BE USED. Designed using Microsoft Word, Dec 99

DD FORM 1695 (SHEET 2)

13. DESCRIPTION OF REVISION (CONTINUED):

13. SHEET 3 VIEW A, ADD FN 200 CALLOUT AND NOTE 30 CALLOUT TO FN116 IN ZONE F8.

14. SHEET 3 VIEW A, ADD NOTE 30 CALLOUT TO FN73 IN ZONE C7.

15. SHEET 4 VIEW J, ADD FN 197 CALLOUT AND NOTE 30 CALLOUT TO FN49 IN ZONE F4.

16. SHEET 4 VIEW J, ADD NOTE 30 CALLOUT TO FN73 IN ZONE C5.

17. SHEET 4 VIEW F-F, ADD NOTE 30 CALLOUT TO FN35 IN ZONE C3.

18. SHEET 4 VIEW F-F, ADD NOTE 30 CALLOUT TO FN175 IN ZONE C3.

The public reporting burden for this collection of information is estimated to average 2 hours per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing the burden, to Department of Defense, Washington Headquarters Services, Directorate for Information Operations and Reports (0704-0188), 1215 Jefferson Davis Highway, Suite 1204, Arlington, VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number.

PLEASE DO NOT RETURN YOUR COMPLETED FORM TO THIS ADDRESS. RETURN COMPLETED FORM TO THE GOVERNMENT ISSUING CONTRACTING

ROOM 238 MACGILLVARY HALL

GEN GREENE AVE

N02

PL 5-4-3200

R

S

13. DESCRIPTION OF REVISION

1. PAGE 2, ADD A NEW “-2 COLUMN” AND COPY ALL -1 COLUMN QTY RQD (FOR FN3-FN8 AND FN12-FN21) INTO THE -2 COLUMN.

FOR FN1 AND FN2, MAKE -2 COLUMN QTY RQD “0”. FOR FN9, MAKE -2 COLUMN QTY RQD “1”. FN10 AND FN11, MAKE -2 COLUMN

QTY RQD “0”.

2. PAGE 3, ADD A NEW “-2 COLUMN” AND COPY ALL -1 COLUMN QTY RQD (FOR FN22-FN34 AND FN36-FN42) INTO THE -2 COLUMN.

FOR FN35, MAKE -2 COLUMN QTY RQD “0”.

3. PAGE 4, ADD A NEW “-2 COLUMN” AND COPY ALL -1 COLUMN QTY RQD (FOR FN43-FN48, FN50, AND FN53-FN63) INTO THE -2

COLUMN. FOR FN49, FN51 AND FN52, MAKE -2 COLUMN QTY RQD “0”.

4. PAGE 5, ADD A NEW “-2 COLUMN” AND COPY ALL -1 COLUMN QTY RQD (FOR FN64-FN72 AND FN74-FN84) INTO THE -2 COLUMN.

FOR FN73, MAKE -2 COLUMN QTY RQD “0”.

5. PAGE 6, ADD A NEW “-2 COLUMN” AND COPY ALL -1 COLUMN QTY RQD (FOR FN85-FN105) INTO THE -2 COLUMN.

6. PAGE 7, ADD A NEW “-2 COLUMN” AND COPY ALL -1 COLUMN QTY RQD (FOR FN106-FN115 AND FN117-FN126) INTO THE -2

COLUMN. FOR FN116, MAKE -2 COLUMN QTY RQD “0”.

7. PAGE 8, ADD A NEW “-2 COLUMN” AND COPY ALL -1 COLUMN QTY RQD (FOR FN127-FN147) INTO THE -2 COLUMN.

8. PAGE 9, ADD A NEW “-2 COLUMN” AND COPY ALL -1 COLUMN QTY RQD (FOR FN148-FN173) INTO THE -2 COLUMN.

9. PAGE 10, ADD A NEW “-2 COLUMN” AND COPY ALL -1 COLUMN QTY RQD (FOR FN174 AND FN176-FN194) INTO THE -2 COLUMN.

FOR FN175, MAKE -2 COLUMN QTY RQD “0”.

(CONTINUED ON SHEET 2)

(2) Revised document must be received before manufacturer may incorporate this change.

(3) Custodian of master document shall make above revision and furnish revised document.

b. ACTIVITY AUTHORIZED TO APPROVE CHANGE FOR GOVERNMENT

US ARMY NATICK SOLDIER RDEC

c. TYPED NAME (First, Middle Initial, Last)

f. DATE SIGNED

(YYYYMMDD)

DD FORM 1695 (SHEET 2)

13. DESCRIPTION OF REVISION (CONTINUED):

10. CREATE A NEW SHEET 11 AND ADD THE FOLLOWING NEW FN’S:

FN195, QTY RQD -1=0, QTY RQD -2=1, CAGE=81337, DWG=5-4-2829, DWG SIZE=E, PART=5-4-2829-2, NOM=FIXED FLOOR ASSY.

FN196, QTY RQD -1=0, QTY RQD -2=1, CAGE=81337, DWG=5-4-2831, DWG SIZE=E, PART=5-4-2831-2, NOM=FIXED ROOF ASSY.

FN197, QTY RQD -1=0, QTY RQD -2=1, CAGE=81337, DWG=5-4-4596, DWG SIZE=E, PART=5-4-4596-1, NOM=HINGED ENDWALL ASSY.

FN198, QTY RQD -1=0, QTY RQD -2=1, CAGE=81337, DWG=5-4-3134, DWG SIZE=E, PART=5-4-3134-2, NOM=FIXED SIDEWALL ASSY.

FN199, QTY RQD -1=0, QTY RQD -2=1, CAGE=81337, DWG=5-4-2835, DWG SIZE=E, PART=5-4-2835-1, NOM=HINGED SIDEWALL ASSY.

FN200, QTY RQD -1=0, QTY RQD -2=1, CAGE=81337, DWG=5-4-2845, DWG SIZE=E, PART=5-4-2845-1, NOM=HINGED END PANEL ASSY.

The public reporting burden for this collection of information is estimated to average 2 hours per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing the burden, to Department of Defense, Washington Headquarters Services, Directorate for Information Operations and Reports (0704-0188), 1215 Jefferson Davis Highway, Suite 1204, Arlington, VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number.

PLEASE DO NOT RETURN YOUR COMPLETED FORM TO THIS ADDRESS. RETURN COMPLETED FORM TO THE GOVERNMENT ISSUING CONTRACTING

ROOM 238 MACGILLVARY HALL

GEN GREENE AVE

N03

5-4-2829

FIXED FLOOR ASSY - ONE SIDE EXPANDABLE

K

L

13. DESCRIPTION OF REVISION

1. SHEET 1, ADD NEW NOTE 12 TO READ “FIND NUMBER IS NOT PROVIDED IN THE 5-4-3200-2 VARIANT.”

2. SHEET 1 ZONE B3, ADD NOTATION TO READ “-2 NOT SHOWN.”

3. SHEET 2 VIEW F-F, ADD NOTE 12 CALLOUT TO: FN15 AND FN17 IN ZONE F7.

(2) Revised document must be received before manufacturer may incorporate this change.

(3) Custodian of master document shall make above revision and furnish revised document.

b. ACTIVITY AUTHORIZED TO APPROVE CHANGE FOR GOVERNMENT

US ARMY NATICK SOLDIER RDEC

c. TYPED NAME (First, Middle Initial, Last)

f. DATE SIGNED

(YYYYMMDD)

The public reporting burden for this collection of information is estimated to average 2 hours per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing the burden, to Department of Defense, Washington Headquarters Services, Directorate for Information Operations and Reports (0704-0188), 1215 Jefferson Davis Highway, Suite 1204, Arlington, VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number.

PLEASE DO NOT RETURN YOUR COMPLETED FORM TO THIS ADDRESS. RETURN COMPLETED FORM TO THE GOVERNMENT ISSUING CONTRACTING

ROOM 238 MACGILLVARY HALL

GEN GREENE AVE

N04

PL 5-4-2829

FIXED FLOOR ASSEMBLY - ONE SIDE EXPANDABLE

H

J

13. DESCRIPTION OF REVISION

1. PAGE 2, ADD A NEW “-2 COLUMN” AND COPY ALL -1 COLUMN QTY RQD (FOR FN1-FN14, FN16 AND FN18-FN21) INTO THE -2

COLUMN. FOR FN15 AND FN17, MAKE -2 COLUMN QTY RQD “0”.

2. PAGE 3, ADD A NEW “-2 COLUMN” AND COPY ALL -1 COLUMN QTY RQD (FOR FN22-FN30) INTO THE -2 COLUMN.

(2) Revised document must be received before manufacturer may incorporate this change.

(3) Custodian of master document shall make above revision and furnish revised document.

b. ACTIVITY AUTHORIZED TO APPROVE CHANGE FOR GOVERNMENT

US ARMY NATICK SOLDIER RDEC

c. TYPED NAME (First, Middle Initial, Last)

f. DATE SIGNED

(YYYYMMDD)

The public reporting burden for this collection of information is estimated to average 2 hours per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing the burden, to Department of Defense, Washington Headquarters Services, Directorate for Information Operations and Reports (0704-0188), 1215 Jefferson Davis Highway, Suite 1204, Arlington, VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number.

PLEASE DO NOT RETURN YOUR COMPLETED FORM TO THIS ADDRESS. RETURN COMPLETED FORM TO THE GOVERNMENT ISSUING CONTRACTING

ROOM 238 MACGILLVARY HALL

GEN GREENE AVE

N05

5-4-2831

FIXED ROOF ASSY - ONE SIDE EXPANDABLE

M

N

13. DESCRIPTION OF REVISION

1. SHEET 1, ADD NEW NOTE 12 TO READ “FIND NUMBER IS NOT PROVIDED IN THE 5-4-3200-2 VARIANT.”

2. SHEET 1 ZONE A5, ADD NOTATION TO READ “-2 NOT SHOWN.”

3. SHEET 1, ADD NOTE 12 CALLOUT TO: FN34, FN46, FN60 AND FN65 IN ZONE D7.

4. SHEET 1, ADD NOTE 12 CALLOUT TO: FN21 IN ZONE E6, FN12 IN ZONE E5, FN21 IN ZONE E5, AND FN12 IN ZONE E4.

(2) Revised document must be received before manufacturer may incorporate this change.

(3) Custodian of master document shall make above revision and furnish revised document.

b. ACTIVITY AUTHORIZED TO APPROVE CHANGE FOR GOVERNMENT

US ARMY NATICK SOLDIER RDEC

c. TYPED NAME (First, Middle Initial, Last)

f. DATE SIGNED

(YYYYMMDD)

The public reporting burden for this collection of information is estimated to average 2 hours per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing the burden, to Department of Defense, Washington Headquarters Services, Directorate for Information Operations and Reports (0704-0188), 1215 Jefferson Davis Highway, Suite 1204, Arlington, VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number.

PLEASE DO NOT RETURN YOUR COMPLETED FORM TO THIS ADDRESS. RETURN COMPLETED FORM TO THE GOVERNMENT ISSUING CONTRACTING

ROOM 238 MACGILLVARY HALL

GEN GREENE AVE

N06

PL 5-4-2831

FIXED ROOF ASSEMBLY - ONE SIDE EXPANDABLE

K

L

13. DESCRIPTION OF REVISION

1. PAGE 2, ADD A NEW “-2 COLUMN” AND COPY ALL -1 COLUMN QTY RQD (FOR FN1-FN11 AND FN13-FN20) INTO THE -2 COLUMN.

FOR FN12 AND FN21, MAKE -2 COLUMN QTY RQD “0”.

2. PAGE 3, ADD A NEW “-2 COLUMN” AND COPY ALL -1 COLUMN QTY RQD (FOR FN22-FN33 AND FN35-FN42) INTO THE -2 COLUMN.

FOR FN34, MAKE -2 COLUMN QTY RQD “59”.

3. PAGE 4, ADD A NEW “-2 COLUMN” AND COPY ALL -1 COLUMN QTY RQD (FOR FN43-FN45, FN47-FN59 AND FN61-FN63) INTO THE -2 COLUMN. FOR FN46, MAKE -2 COLUMN QTY RQD “42”. FOR FN60, MAKE -2 COLUMN QTY RQD “0”.

4. PAGE 5, ADD A NEW “-2 COLUMN” AND COPY ALL -1 COLUMN QTY RQD (FOR FN64 AND FN66-FN73) INTO THE -2 COLUMN.

FOR FN65, MAKE -2 COLUMN QTY RQD “42”.

(2) Revised document must be received before manufacturer may incorporate this change.

(3) Custodian of master document shall make above revision and furnish revised document.

b. ACTIVITY AUTHORIZED TO APPROVE CHANGE FOR GOVERNMENT

US ARMY NATICK SOLDIER RDEC

c. TYPED NAME (First, Middle Initial, Last)

f. DATE SIGNED

(YYYYMMDD)

The public reporting burden for this collection of information is estimated to average 2 hours per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing the burden, to Department of Defense, Washington Headquarters Services, Directorate for Information Operations and Reports (0704-0188), 1215 Jefferson Davis Highway, Suite 1204, Arlington, VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number.

PLEASE DO NOT RETURN YOUR COMPLETED FORM TO THIS ADDRESS. RETURN COMPLETED FORM TO THE GOVERNMENT ISSUING CONTRACTING

ROOM 238 MACGILLVARY HALL

GEN GREENE AVE

N07

5-4-3134

FIXED SIDEWALL ASSY – W/ ENVIR CONTR UNIT OPENINGS

F

G

13. DESCRIPTION OF REVISION

1. SHEET 1, ADD NEW NOTE 2 TO READ “FIND NUMBER IS NOT PROVIDED IN THE 5-4-3200-2 VARIANT.”

2. SHEET 1 ZONE B4, ADD NOTATION TO READ “-2 NOT SHOWN.”

3. SHEET 1, ADD NOTE 2 CALLOUT TO THE LOWER ENVIRONMENTAL CONTROL UNIT OPENING IN ZONE D4.

(2) Revised document must be received before manufacturer may incorporate this change.

(3) Custodian of master document shall make above revision and furnish revised document.

b. ACTIVITY AUTHORIZED TO APPROVE CHANGE FOR GOVERNMENT

US ARMY NATICK SOLDIER RDEC

c. TYPED NAME (First, Middle Initial, Last)

f. DATE SIGNED

(YYYYMMDD)

The public reporting burden for this collection of information is estimated to average 2 hours per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing the burden, to Department of Defense, Washington Headquarters Services, Directorate for Information Operations and Reports (0704-0188), 1215 Jefferson Davis Highway, Suite 1204, Arlington, VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number.

PLEASE DO NOT RETURN YOUR COMPLETED FORM TO THIS ADDRESS. RETURN COMPLETED FORM TO THE GOVERNMENT ISSUING CONTRACTING

ROOM 238 MACGILLVARY HALL

GEN GREENE AVE

N08

PL 5-4-3134

FIXED SIDEWALL ASSY – W/ ECU OPENINGS

B

C

13. DESCRIPTION OF REVISION

1. PAGE 2, ADD A NEW “-2 COLUMN” AND FOR BOTH FN1 AND FN2 MAKE -2 COLUMN QTY RQD “1”.

(2) Revised document must be received before manufacturer may incorporate this change.

(3) Custodian of master document shall make above revision and furnish revised document.

b. ACTIVITY AUTHORIZED TO APPROVE CHANGE FOR GOVERNMENT

US ARMY NATICK SOLDIER RDEC

c. TYPED NAME (First, Middle Initial, Last)

f. DATE SIGNED

(YYYYMMDD)

ECP 5-4-3200
ENGINEERING CHANGE PROPOSAL
PROCURING ACTIVITY NUMBER
OPTIONAL CLOSEOUT PANEL ASSEMBLIES
I
YES
NO
FIXED FLOOR ASSY
THE FOLLOWING COMPONENTS OF THE SHELTER ASSEMBLY ONE SIDE EXPANDABLE – 100 AMP ARE MADE OPTIONAL:
THE THREE (3) CLOSEOUT PANEL ASSEMBLIES LOCATED ON THE TWO HINGED SIDEWALL ASSEMBLIES AND THE HINGED
SIDEWALL ASSEMBLY.
THE LOWER CLOSEOUT FRAME INSTALLATION AND CLOSEOUT PANEL ASSEMBLY LOCATED ON THE FIXED SIDEWALL.
THE ECU INTAKE AND ECU RETURN PANEL ASSEMBLIES STOWED ON THE FIXED ROOF.
THE FOUR (4) STOWAGE CHANNEL ASSEMBLIES LOCATED ON THE FIXED ROOF.
THE MANUAL HOLDER LOCATED NEXT TO THE PERSONNEL DOOR.
A LONG TERM CUSTOMER FOR THE SHELTER ASSEMBLY ONE SIDE EXPANDABLE – 100 AMP DOES NOT UTILIZE THE THREE CLOSEOUTS AND THE ADDITIONAL COMPONENTS LISTED ABOVE AND SEEKS TO MAKE THEM OPTIONAL IN ORDER TO REDUCE THE OVERALL COST OF THE 2:1 ISO 100 AMP SHELTER.

X

6NOV ECP
ECP 5-4-3200
ENGINEERING CHANGE PROPOSAL
PROCURING ACTIVITY NUMBER
OPTIONAL CLOSEOUT PANEL ASSEMBLIES
I
YES
NO
FIXED FLOOR ASSY
THE THREE (3) CLOSEOUT PANEL ASSEMBLIES LOCATED ON THE TWO HINGED SIDEWALL ASSEMBLIES AND THE HINGED SIDEWALL ASSEMBLY ARE MADE OPTIONAL. THE LOWER CLOSEOUT FRAME INSTALLATION AND CLOSEOUT PANEL ASSEMBLY LOCATED ON THE FIXED SIDEWALL ARE MADE OPTIONAL. THE ECU INTAKE AND ECU RETURN PANEL ASSEMBLIES ARE MADE OPTIONAL ALONG WITH THE FOUR (4) STOWAGE CHANNEL ASSEMBLIES LOCATED ON THE FIXED ROOF. THE MANUAL HOLDER IS MADE OPTIONAL.
A LONG TERM CUSTOMER FOR THE SHELTER ASSEMBLY ONE SIDE EXPANDABLE – 100 AMP DOES NOT UTILIZE THE THREE CLOSEOUTS AND THE ADDITIONAL COMPONENTS LISTED ABOVE AND SEEKS TO MAKE THEM OPTIONAL IN ORDER TO REDUCE THE OVERALL COST OF THE 2:1 ISO 100 AMP SHELTER.

X

NOR N01 5-4-3200
THIS REVISION DESCRIBED BELOW HAS BEEN AUTHORIZED FOR THE DOCUMENT LISTED
Form Approved
NOR N02 PL5-4-3200
THIS REVISION DESCRIBED BELOW HAS BEEN AUTHORIZED FOR THE DOCUMENT LISTED
Form Approved
NOR N03 5-4-2829
THIS REVISION DESCRIBED BELOW HAS BEEN AUTHORIZED FOR THE DOCUMENT LISTED
Form Approved
NOR N04 PL5-4-2829
THIS REVISION DESCRIBED BELOW HAS BEEN AUTHORIZED FOR THE DOCUMENT LISTED
Form Approved
NOR N05 5-4-2831
THIS REVISION DESCRIBED BELOW HAS BEEN AUTHORIZED FOR THE DOCUMENT LISTED
Form Approved
NOR N06 PL5-4-2831
THIS REVISION DESCRIBED BELOW HAS BEEN AUTHORIZED FOR THE DOCUMENT LISTED
Form Approved
NOR N07 5-4-3134
THIS REVISION DESCRIBED BELOW HAS BEEN AUTHORIZED FOR THE DOCUMENT LISTED
Form Approved
NOR N08 PL5-4-3134
THIS REVISION DESCRIBED BELOW HAS BEEN AUTHORIZED FOR THE DOCUMENT LISTED
Form Approved