03321_AE200 - BUILDING ELEVATIONS AND SECTIONS.pdf

PDF 629 KB Posted

Attached to
CONSTRUCT MUNITIONS MAINTENANCE, INSPECTION, AND ASSEMBLY (M&I) FACILITY Federal contract opportunity
Solicitation number
W50S9F-24-B-0001
Issued by
Department of the Army National Guard

About this file

This document is a set of building elevations and sections related to a federal contract opportunity for the construction of a Munitions Maintenance, Inspection, and Assembly (M&I) Facility at Truax Field in Madison, Wisconsin.

The key details of the federal contract opportunity include: the solicitation is for a firm fixed-price construction contract to build a new 3,500 sq ft earth-covered, two-bay M&I facility to support F-35 mission-specific operations; the work includes constructing a new Secure Work Area, providing new mechanical, electrical, and fire protection systems, and site work such as a Munitions Assembly Conveyor pad and a new access road. The project has a brand name requirement for specific security system, DDC software, keys/cores, and fire alarm panels. The contract duration is 273 calendar days and the project is set aside 100% for Small Businesses under NAICS code 236220. A pre-bid conference and site visit will be held, and bids will be publicly opened. Interested contractors must be registered in SAM.gov.

View the file

Other files for this federal contract opportunity

Other files attached to CONSTRUCT MUNITIONS MAINTENANCE, INSPECTION, AND ASSEMBLY (M&I) FACILITY, newest first.
File Type Posted
ABSTRACT OF OFFERS - CONSTRUCTION_24B0001.pdf PDF
Question and Answers Log_Questions 1-37 FINAL.pdf PDF
Question and Answers Log_Questions 1-37v1.pdf PDF
W50S9F-24-B-0001_00001.pdf PDF
Question and Answers Log_Questions 1-37.pdf PDF
Question and Answers Log_Questions 1-32.pdf PDF
SECTION 27 10 00 BUILDING TELECOMMUNICATIONS CABLING SYSTEM.pdf PDF
Question and Answers Log_Questions 1-26.pdf PDF
Attendance Sheet MI Pre-Bid Conference 20240502.pdf PDF
08 39 55 Sliding Metal Blast Resistant Doors.pdf PDF
Pre-Bid Conference Minutes.pdf PDF
07 14 00 Fluid-applied waterproofing.pdf PDF
03321_AE301 - WALL SECTIONS.pdf PDF
Add 3 Table of Contents.pdf PDF
Pre-Bid Conference Slides - MI.pdf PDF
ATTACHMENT 2 - Add No. 2 - PLANS AND SPECIFICATIONS Vol 2 Project No. XGFG219012.pdf PDF
ATTACHMENT 7 - XGFG 219012 MI Facility - Single Source Doc - Monaco Fire Alarm_Redacted.pdf PDF
ATTACHMENT 8 - XGFG219012 MI Facility - Single Source Doc - Schneider_Andover_Redacted.pdf PDF
ATTACHMENT 9 - SFS Form 12 - Template.xls XLS spreadsheet
ATTACHMENT 4 - GEOTECHNICAL ENGINEERING REPORT.pdf PDF
ATTACHMENT 5 - XGFG219012 MI Facility - Single Source Doc - Advantor_Redacted.pdf PDF
ATTACHMENT 1 - PLANS AND SPECIFICATIONS Vol 1 Project No. XGFG219012.pdf PDF
ATTACHMENT 2 - PLANS AND SPECIFICATIONS Vol 2 Project No. XGFG219012.pdf PDF
W50S9F-24-B-0001.pdf PDF
ATTACHMENT 3 - DRAWINGS Project No. XGFG219012 Dated 27 Oct 23.pdf PDF
ATTACHMENT 6 -XGFG219012 MI Facility - Single Source Doc - Marshall Best_Redacted.pdf PDF
Show all 26

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

GROUND FLOOR

100'-0"

T.O. ROOF

118'-0"

T.O. BACK WALL

121'-2"

CONCRETE WALLS BEYOND (EXT PT)

WALL PACK LIGHTS

SLOPED CONC.

RETAINING WALL

SELECT FILL SLOPED FOR

POSITIVE DRAINAGE

MECHANICAL EQPT.ELECTRICAL EQPT.

CONCRETE ROOF (EXT PT)

PERIMETER DRAINAGE

PREFINISHED METAL PARAPET

CAP

STRUCTURAL BRACING WALL

COVERED BY FILL (BEYOND)

STRUCTURAL

BRACING WALL

COVERED BY FILL

(BEYOND)

GROUND FLOOR

100'-0"

T.O. ROOF

118'-0"

AE301

A4

4 2 1

T.O. FRONT WALL

121'-8"

'-9

2'-6"

MECH. LOUVER LIGHT

FIXTURE

TOP OF

CONC WALL

CONCRETE RETAINING

WALL (EXT PT)

FIRE

PROTECTION

2'-6"

'-9

LIGHT

FIXTURE

LIGHT

FIXTURE

LIGHTNING

PROTECTION

VHF

ANTENNA

OUTLINE OF SELECT FILL

EARTH ON OPPOSITE

SIDE OF WALL

MECH. LOUVER

HM DOOR AND FRAMESLIDING BLAST- RESISTANT

HANGAR DOOR

LINE OF FINISHED ROOF

LIGHTNING

PROTECTIONLIGHTNING

PROTECTION

'-0

PREFINISHED METAL

PARAPET CAP

3A

SLIDING BLAST-

RESISTANT HANGAR

DOOR

2A

CJ CJ CJ CJ

6" STEEL PIPE

BOLLARD - TYP

CJ

CJ

CJ CJ

CJ

20'-0" 11'-6" 8'-6" 16'-0" 4'-6" 12'-9" 12'-9" 4'-6" 16'-0" 8'-6" 11'-6" 20'-0"

'-0

GROUND FLOOR

100'-0"

T.O. ROOF

118'-0"

AE200

C1 A2

AE301

A2

AE301

Sim

MECH & COMP

COMM

VEST

VEST

A B

GROUND COVER

CONCRETE

WALL BEYOND

(EXT PT)

B.O. DBL T BEAM

115'-4"

T.O. FRONT WALL

121'-8"

T.O. BACK WALL

121'-2"

DRAINAGE BOARD

WATER PROOFING

2" INSULATION

SELECT FILL, 12"

MIN.

1/8" / 1'-0"

LIGHT FIXTURE

MECH. EQPT.

A1

AE301

Sim A1

AE301

Sim

CONCRETE

WALL (EXT PT)

PREFINISHED

METAL PARAPET

CAP

LIGHT FIXTURE

CLAY TOPPING,

16" MIN.

GROUND FLOOR

100'-0"

T.O. ROOF

118'-0"

AE200

C1A3

AE301 A1

AE301

Sim

MISSILE BAY 2

100SLIDING BLAST-

RESISTANT

HANGAR DOOR

CONCRETE WALL

(EXT PT)

A B

T.O. FRONT WALL

121'-8"

T.O. BACK WALL

121'-2"

LIGHT FIXTURE

GROUND COVER

DRAINAGE BOARD

WATER PROOFING

2" INSULATION

SELECT FILL, 12" MIN.

SELECT FILL

CONCRETE WALL BEYOND

DOUBLE TEE - RE:

STRUCTURE

0A

STRUCTURAL FOOTING

CONC. RETAINING WALL BEYOND

2' -0

PERIMETER DRAINAGE

PREFINISHED

METAL PARAPET

CAP

CLAY TOPPING,

16" MIN

GROUND FLOOR

100'-0"

T.O. ROOF

118'-0"

AE200

D3

AE200

D1

A1

AE301

A1

AE301

Sim

MISSILE BAY 2

ELEC.

MISSILE BAY 1

SECURED

WORK AREA

CONCRETE DECK

B.O. DBL T BEAM

115'-4"

T.O. BACK WALL

121'-2"

DRAINAGE BOARD

WATER PROOFING

2" INSULATION

SELECT FILL, 12" MIN.

RUNWAY BEAM

CONCRETE WALL

STRUCTURAL FOOTING

PERFORATED DRAINAGE PIPE

PERIMETER DRAINAGE PIPE

COMM

CLAY TOPPING, 16" MIN.

RUNWAY BEAM

B

4" MIN. PERFORATED PIPE W/

WOVEN FABRIC MESH

WRAPPED COMPLETELY

AROUND PIPE

DRAINAGE BOARD

CONC. WALL

GRANULAR FILL

(#57 STONE MIN)

CONC. WALL

BACK FILL

WOVEN FABRIC

GEOTEXTILE

MESH

DRAINAGE

BOARD

FLUID-APPLIED

WATERPROOFING

ON ALL BEOLOW

GRADE CONCRETE

SURFACES

FILTER LAYER FABRIC

FLUID-APPLIED

WATERPROOFING

WATERSTOP -

TYP.

WATERSTOP -

TYP.

2" RIGID INSULATION

BOARD

2" RIGID

INSULATION

BOARD

5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436

405.840.2931 | fsb-ae.com

D

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

C

B

A

D

C

B

A

54321

FSB2020-332-01

MJT

M un iti on s M &I

F ac ilit y

Tr ua x F ie ld , M ad iso n, W is co ns in

F-

B ed do wn

OCTOBER 27, 2023

C :\U sers\bkg\D o cum ents\M y R evit\03321_Arch_B G allagher5S

B23.rvt

5/9/2024 10:03: 25 AM

BUILDING ELEVATIONS AND

SECTIONS

AE200

CKG

BKG

MJT

SCALE: 1/8" = 1'-0"

EAST ELEVATIONB1

SCALE: 1/8" = 1'-0"

WEST ELEVATIONA1

0 4' 8' 16'

1/8" = 1'-0"

SCALE: 1/8" = 1'-0"

BUILDING SECTIOND1 SCALE: 1/8" = 1'-0"

BUILDING SECTIOND3

SCALE: 1/8" = 1'-0"

BUILDING SECTIONC1 SCALE: 3/4" = 1'-0"

DETAILC4

1' 3'2'0

3/4" = 1'-0"

1 ADDENDUM #2 02/12/2024

2 ADDENDUM #3 05/09/2024

File details come from the government source that posted it. Updated .