XGFG112032 Repair B412 Alert Shelters - EPDM Roof Submittal.pdf
PDF 5 MB Posted
- Attached to
- F-35 Alter B412 Flow -Through Aircraft Shelter
- Solicitation number
- W50S9F22R0003
- Issued by
-
Department of the Army National Guard
About this file
This is a solicitation for a firm fixed-price construction contract to alter an F-35 aircraft maintenance hangar at Truax Field Air National Guard Base in Madison, Wisconsin. The project scope includes minor demolition, utility improvements, rooftop and interior fall protection systems, upgraded aircraft fire detection and suppression, specialized aircraft mechanical and electrical systems, an upgraded lightning protection system, security system upgrades, and modified technology systems. The contract value is estimated between $5-10 million. A pre-proposal conference will be held on April 8, 2022 and proposals are due April 1, 2022. The evaluation criteria are technical approach, past performance, and price. The government intends to award without discussions. Two brand name products are required: Marshall Best Security Corp. keys and cores and Monaco Vulcan fire alarm panels. At least 85% of the contract value must go to similarly situated entities, excluding materials costs. The North American Industry Classification code is 236220.
View the file
Other files
Show all 36
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
OMB NO. 9000-0062
NEW
ITEM
NO.
DATE
DATE
RECOMMEND APPROVAL
DATE
REQUEST RESUBMITTAL ON DISAPPROVED ITEMS WITHIN _______________ DAYS OF DATE SHOWN BELOW.
DATE
AF FORM 3000, 19910901 (EF-V2) PREVIOUS EDITION IS OBSOLETE
Public reporting burden for this collection of information is estimated to average 20 minutes per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden to the Department of Defense, Washington
Headquarters. Services. Directorate for information Operations and Reports. 1215 Jefferson Davis Highway, Suite 1204, Arlington VA 22202-4302, and to the Office of Management and Budget, Paperwork Reduction Project OMB No 9000-
0062, Washington DC 20503. Please DO NOT RETURN your form either of these addresses. Send your completed form to: SAF/AQCO, Pentagon, Washington DC 20330-1000.
FORM APPROVED
Expires Apr.30 1993
MATERIAL APPROVAL SUBMITTAL
(See Instructions on Reverse)
TO: ( Contracting Officer)
MSGT Katherine Pinnow
CONTRACT NUMBER
W912J2-11-D-0017-1015
SUBMISSION NUMBER
DATEFROM: (Contactor)
9/10/15Patrick Baldwin
Advanced Building Corp.
PARA NO./DRAWING NO. (Include Type, Model Number, Catalog, Mfg.,etc.)
DESCRIPTION OF MATERIALSPECIFICATION SECTION /
PREVIOUS SUBMITTAL NUMBER
TO BE COMPLETED BY CONTRACTOR
SUBMITTAL
FOR GOVERNMENT USE ONLY
APPROVED
DISAP-
PROVED
SEE
REVERSE
INITIAL
PROJECT NUMBER
RESUBMITTAL
EPDM product data
Patrick Baldwin, Business Development
07.53.23
TYPE OR PRINT NAME AND TITLE SIGNATURE
TYPE OR PRINT NAME AND GRADE SIGNATURE
TO: (AF Contracting Office)
BY COMPLETING THIS FORM, THE UNDERSIGNED CONTRACTOR CERTIFIES THAT
THE MATERIAL COMPLIES WITH ALL SPECIFICATIONS OF SUBJECT CONTRACT.
TYPE OR PRINT NAME AND GRADE
TYPE OR PRINT NAME AND GRADE
DISAPPROVAL AS INDICATED ABOVE AND SUBJECT TO ANY APPLICABLE COMMENTS ON THE REVERSE
TO: (CONTRACTOR)
FOR GOVERNMENT USE ONLY
TO: (Base Civil Engineering Officer)
For Evaluation and Action
SIGNATURE
SIGNATURE
DISAPPROVED AS INDICATED ABOVE AND SUBJECT TO ANY APPLICABLE COMMENTS ON THE REVERSE SIDE.
APPROVED
9/14/2015
XGFG112032
35 Qualification data07.53.23
37 Sample Warranty07.53.23
896BOK
Text Box
896BOK
Text Box
896BOK
Text Box
896BOK
Text Box
896BOK
Text Box
896BOK
Text Box 075323
896BOK
Text Box 075323
896BOK
Text Box 075323
896BOK
Text Box 075323
896BOK
Text Box 075323
896BOK
Text Box 1.5.E - Manufacturer's Certificates
896BOK
Text Box 1.5.F - Sample NDL Warranty
896BOK
Typewritten Text X
896BOK
Typewritten Text
896BOK
Typewritten Text
896BOK
Typewritten Text X
896BOK
Typewritten Text X
896BOK
Typewritten Text X
896BOK
Typewritten Text X
896BOK
Typewritten Text
896BOK
Typewritten Text
896BOK
Typewritten Text X
896BOK
Typewritten Text
896BOK
Typewritten Text
BOK
896BOK
Typewritten Text
BOK
896BOK
Typewritten Text
BOK
896BOK
Typewritten Text
BOK
896BOK
Typewritten Text
BOK
896BOK
Typewritten Text
896BOK
Typewritten Text
896BOK
Text Box Note to Contractor:
Item No. must match the line item on the AF Form 66 for submittals in specification section 013000.
896BOK
Line
896BOK
Line
896BOK
Text Box Note to Contractor:
Provide all Action Items in a single submittal where noted in each specification section so the A/E and Government can confirm all items required for review prior to Contractor procurement comply with the contract documents. Item No. 53, 55, and 57 where provided by the Contractor on this form. Fortunately, Item No. 54 and 56 were provided in the submittal. Mead & Hunt edited the AF Form 3000 to expedite the submittal.
896BOK
Text Box 1.5.B - Product Data
896BOK
Text Box 1.5.C - Shop Drawings
896BOK
Text Box 1.5.D - Qualification Data
896BOK
Line
896BOK
Line
896BOK
Typewritten Text 9/15/2015
896BOK
Typewritten Text Bernie Krusel, Job Captain - Mead & Hunt, Inc.
896BOK
Typewritten Text
896BOK
Bernie Krusel
1138452693N Stamp
1138452693N Typewritten Text 22 Sept 15
1138452693N Typewritten Text MICHAEL J. DUNLAP, Maj
X:\3141300\131957.01\CORR\4Const\shop dwgs\075323.001 - EPDM Roofing\001 - 075323-01 Submit'l Cvr.doc
SUBMITTAL COVER SHEET
Submittal #001 – EPDM Roofing
Contractor: Advanced Building Corp.
Reviewed By: Bernie Krusel
Copies to: KO & COR
Submittal documents for the above project were received and reviewed, and comments are listed below. Checking is only for conformance with the design concept of the Project and compliance with the information given in the Contract Documents. The Contractor is responsible for dimensions to be confirmed and correlated at the job site; for information that pertains solely to the fabrication processes or to techniques of construction; and for coordination of the work of all trades. Review and comment does not relieve the contractor from compliance with the requirements of the drawings and specifications.
Review Comments
Submittal Reference Review Response
Comments
Item 53 – Section 075232 EPDM Roofing 1.5.B, Product Data
Approved
Item 54 – Section 075232 EPDM Roofing 1.5.C, Shop Drawings
Approved
Item 55 – Section 075232 EPDM Roofing 1.5.D, Qualification Data
Approved
Item 56 – Section 075232 EPDM Roofing 1.5.E, Manf. Certificates
Approved See Comments
Qualification Data not submitted however manufacturer and products noted in submittal are the basis-of-design provided in the A/E’s specification; therefore accepted.
Item 57 – Section 075232 EPDM Roofing 1.5.F, Sample Warranty
Approved
Please call Kent Falligant at (608) 273-6380 with any questions regarding this submittal.
OWNER: USPFO for Wisconsin – 115 FW/MSC ARCHITECT/
ENGINEER:
Mead & Hunt, Inc.
SMSgt Katherine Pinnow, Contracting Officer Kent Falligant, Construction Administrator 3110 Mitchell Street, Bldg 510 2440 Deming Way, Middleton, WI 53562 Madison, WI 53704-2591 Ph. (608) 273-6380 Fax (608) 273-6391 Ph. (608) 245-4548
PROJECT: Repair Aircraft Shelter, B412 PROJECT NO.: 3141300-131957.01 Truax Field ANGB DATE: September 15, 2015 Madison, WI 53704
PROJECT NO.: XGFG 112032
Firestone Building Products Submittal Package
Project Name: ANG Building 412
Address: 3110 Mitchell Street
City: Madison
State/Zip: WI 53704-2529
Created For: Gary Brown Roofing Co.
Date: Wednesday, September 2, 2015
For installation of a Firestone Adhered - EPDM roofing system.
FBPCO Number: CG9124
Table of Contents Table of Contents i Sample Warranty ii Contractor Letter in Good Standing iv
1. Area 1- CG9124 1 Pre-installation Notice 2 LS-1.pdf 3 RE-23_10.22.14.pdf 4 BT-2.pdf 5 C-1.pdf 6 D-1 .pdf 7 TIS 103 EPDM LS-FR 7-15-13.pdf 8 TIS 817 Bonding Adhesive BA-2004 (T).pdf 10 TIS.1402.QuickSeam Flashing.020612.pdf 13 TIS.1412.QuickPrime Plus LVOC.021312.pdf 14 TIS.1408.QuickSeam Corner Flashing.020912.pdf 16 TIS.1409.QuickSeam Pipe Flashing.020912.pdf 17 TIS 1411 QuickPrime Plus.080213.pdf 19 TIS 901 ISO 95+ GL 7-17-2014.pdf 21 TIS 910 DensDeck Prime Roof Board 1-21-13.pdf 24 TIS_1106_InsulationPlate_01.30.2013.pdf 26 TIS 1002 Heavy Duty Fasteners 1-11-13.pdf 27 Red Shield Wty SAMPLE.pdf 29
Submittal package prepared for Gary Brown Roofing Co., Page i
RED SHIELD ROOFING SYSTEM LIMITED WARRANTY
Warranty No: FBPCO # Square Footage: s.f.
Building Owner:
Building Identification:
Building Address:
Warranty Period Of:
Roofing Contractor:
For the warranty period indicated above, Firestone Building Products Company, LLC (“Firestone”), an Indiana limited liability company, warrants to the Building Owner (“Owner”) named above that Firestone will, subject to the Terms, Conditions and Limitations set forth below, repair any leak in the Firestone Roofing System (“System”).
TERMS, CONDITIONS AND LIMITATIONS
1. Products Covered. The System shall mean only the Firestone brand roofing membranes, Firestone brand roofing insulations, Firestone brand roofing metal, and other Firestone brand roofing accessories when installed in accordance with Firestone technical specifications by a Firestone-licensed applicator.
2. Notice. In the event any leak should occur in the System, the Owner must give notice in writing or by telephone to Firestone within thirty (30) days of any occurrence of a leak. Written notice may be sent to Firestone at the street address or fax number shown on the reverse side of this Limited Warranty. Evidence of this notice shall be the receipt by Owner of a Firestone Leak Notification Acknowledgement. By so notifying Firestone, the Owner authorizes Firestone or its designee to investigate the cause of the leak.
3. Investigation. If upon investigation, Firestone determines that the leak is not excluded under the Terms, Conditions and Limitations set forth in this Red Shield Roofing System Limited Warranty (the “Limited Warranty”), the Owner’s sole and exclusive remedy and Firestone’s total liability shall be limited to the repair of the leak. Should the investigation reveal that the leak is excluded under the Terms, Conditions and Limitations, the Owner shall be responsible for payment of the investigation costs. Failure by Owner to pay for these costs shall render this Limited Warranty null and void. Firestone will advise the Owner of the type and/or extent of repairs required to be made at the Owner’s expense that will permit this Limited Warranty to remain in effect for the unexpired portion of its term. Failure by the Owner to properly make these repairs in a reasonable manner using a Firestone-licensed applicator and within 60 days shall render this Limited Warranty null and void.
4. No Dollar Limit (NDL). There is no dollar limit placed on warranted leak repairs to the extent such repairs are covered by this Limited Warranty.
5. Disputes. Any dispute, controversy or claim between the Owner and Firestone concerning this Limited Warranty shall be settled by mediation. In the event that the Owner and Firestone do not resolve the dispute, controversy or claim in mediation, the Owner and Firestone agree that neither party will commence or prosecute any suit, proceeding, or claim other than in the courts of Hamilton County in the state of Indiana or the United States District Court, Southern District of Indiana, Indianapolis Division. Each party irrevocably consents to the jurisdiction and venue of the above-identified courts.
6. Payment Required. Firestone shall have no obligation under this Limited Warranty unless and until Firestone and the licensed applicator have been paid in full for all materials, supplies, services, approved written change orders, warranty costs and other costs which are included in, or incidental to, the System. In the event that repairs not covered by this Limited Warranty are necessary in the future, Firestone reserves the right to suspend this Limited Warranty until such repairs have been completed and the licensed applicator and/or Firestone has been paid in full for such repairs.
Exclusions. Firestone shall have no obligation under this Limited Warranty, or any other liability, now or in the future if a leak or damage is caused by:
(a) Natural forces, disasters, or acts of God including, but not limited to, fires, hurricanes, tornadoes, hail, wind-blown debris, lightning, earthquakes, volcanic activity, atomic radiation, insects or animals; (b) Winds of peak gust speed at or in excess of MPH calculated at ten(10) meters above ground using available meteorological data;(c) Act(s), conduct or omission(s) by any person, or act(s) of war, terrorism or vandalism, which damage the System or which impair the System’s ability to resist leaks; (d) Failure by the Owner to use reasonable care in maintaining the System, said maintenance to include, but not be limited to, those items listed on the reverse side of this Limited Warranty entitled “Building Envelope Care and Maintenance Guide”;
(e) Deterioration or failure of building components, including, but not limited to, the roof substrate, walls, mortar, HVAC units, skylights etc.; (f) Construction generated moisture, condensation or infiltration of moisture in, from, through, or around the walls, copings, rooftop hardware or equipment, skylights, building structure or underlying or surrounding materials; (g) Acid, oil, harmful chemicals, or the reaction between them; (h) Alterations or repairs to the System that are not completed in accordance with Firestone’s published specifications, not completed by an approved contractor, and/or not completed with proper notice to Firestone; (i) The design of the roofing system: Firestone does not undertake any analysis of the architecture or engineering required to evaluate what type of System is appropriate for a building and makes no warranty express or implied as to the suitability of its Products for any particular structure; such a determination is the responsibility of the architect, engineer or design professional; (j) Improper selection of materials for the roof assembly or the failure to accurately calculate wind uplift and/or roof loads;(k) Deterioration to metal roofing materials and accessories caused by marine salt water, atmosphere, or by regular spray of either salt or fresh water; or, (l) Change in building use or purpose.
7. Transfer. This Limited Warranty shall be transferable subject to Owner’s payment of the current transfer fee set by Firestone.
8. Term. The term of this Limited Warranty shall be for the period set forth above and such term shall not be extended under any circumstances.
9. Roof Access. During the term of this Limited Warranty, Firestone’s designated representative or employees shall have free access to the roof during regular business hours. In the event that roof access is limited due to security or other restrictions, Owner shall reimburse Firestone for all reasonable cost incurred during inspection and/or repair of the System that are due to delays associated with said restrictions. Owner shall be responsible for the damage caused by, removal and replacement of any overburdens, superstrata or overlays, either permanent or temporary, excluding accepted stone ballast or pavers, as necessary to expose the system for inspection and/or repair.
10. Waiver. Firestone’s failure to enforce any of the terms or conditions stated herein shall not be construed as a waiver of such provision or of any other terms and conditions of this Limited Warranty.
11. Governing Law. This Limited Warranty shall be governed by and construed in accordance with the laws of the State of Indiana without regard to that State’s rules on conflict of laws.
12. Severability. If any portion of this Limited Warranty is held by a court of competent jurisdiction to be invalid, void or unenforceable, the remaining provisions shall nevertheless continue in full force.
FIRESTONE DOES NOT WARRANT PRODUCTS INCORPORATED OR UTILIZED IN THIS INSTALLATION THAT WERE NOT FURNISHED BY FIRESTONE.
FIRESTONE SPECIFICALLY DISCLAIMS LIABILITY UNDER ANY THEORY OF LAW ARISING OUT OF THE INSTALLATION OF, PERFORMANCE OF, OR
DAMAGES SUSTAINED BY OR CAUSED BY, PRODUCTS NOT FURNISHED BY FIRESTONE.
THIS LIMITED WARRANTY SUPERSEDES AND IS IN LIEU OF ALL OTHER WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, AND FIRESTONE HEREBY DISCLAIMS ALL SUCH WARRANTIES. THIS LIMITED WARRANTY SHALL BE THE OWNER’S SOLE AND EXCLUSIVE REMEDY AGAINST FIRESTONE, AND FIRESTONE SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, SPECIAL, INCIDENTAL OR OTHER DAMAGES INCLUDING, BUT NOT LIMITED TO, LOSS OF PROFITS OR DAMAGES TO THE BUILDING OR ITS CONTENTS OR THE ROOF DECK. THIS LIMITED WARRANTY CANNOT BE AMENDED, ALTERED OR MODIFIED IN ANY WAY EXCEPT IN WRITING SIGNED BY AN AUTHORIZED OFFICER OF FIRESTONE. NO OTHER PERSON HAS ANY AUTHORITY TO BIND FIRESTONE WITH ANY REPRESENTATION OR WARRANTY WHETHER ORAL OR WRITTEN.
FIRESTONE BUILDING PRODUCTS COMPANY, LLC
By:
Authorized Signature: _____________________________________
Title:
Signature
040907
SAMPLE CG9124 41000
115FW/LGC Wisconsin Air National Guard
ANG Building 412 3110 Mitchell Street, Madison, WI, 53704-2529
TWENTY (20) Years, Beginning On:
GARY BROWN ROOFING COMPANY
Chris Huettig
Director, Quality Building Services
Submittal package prepared for Gary Brown Roofing Co., Page ii
250 West 96th Street – Indianapolis, IN 46260
1-800-428-4442 * 1-317-575-7000 * FAX 1-317-575-7100
www.firestonebp.com
BUILDING ENVELOPE CARE AND MAINTENANCE GUIDE
(For Red Shield Warranted Roofing Systems)
Congratulations on your purchase of a Firestone Roofing System! Your roof is a valuable asset that should be properly maintained. Firestone Building Products recommends that all roofs and roofing systems receive periodic inspections and maintenance to ensure that they perform as designed.
1. The roof should be inspected at least twice yearly and after any severe storms. A record of all inspection and maintenance activities should be maintained, including a listing of the date and time of each activity as well as the identification of the parties performing the activity.
2. Proper maintenance and good roofing practice require that ponded water (defined as water standing on the roof forty-eight hours after it stops raining) not be allowed on the roof. Roofs should have slope to drain, and all drain areas must remain clean. Bag and remove all debris from the roof since such debris can be quickly swept into drains by rain. This will allow for proper water run-off and avoid overloading the roof.
3. The Firestone Roofing System should not be exposed to acids, solvents, greases, oil, fats, chemicals and the like. If the Firestone Roofing System is in contact with any such materials, these contaminants should be removed immediately and any damaged areas should be inspected by a Firestone Licensed Applicator and repaired if necessary.
4. The Firestone Roofing System is designed to be a waterproofing membrane and not a traffic surface. Roof traffic other than periodic traffic to maintain rooftop equipment and conduct periodic inspections should be prohibited. In any areas where periodic roof traffic may be required to service rooftop equipment or to facilitate inspection of the roof, protective walkways should be installed by a Firestone Licensed Applicator as needed to protect the roof surface from damage.
5. Firestone recommends periodic maintenance for some roofing membranes:
a. Smooth-surfaced Firestone APP membranes should be coated with an approved liquid coating, such as Firestone Aluminum Roof Coating or Firestone AcryliTop applied in accordance with Firestone specifications, in order to maximize the service life of the membrane. If this coating is not applied as part of the initial roofing installation, it should be applied within the first five years after the roof is installed to help protect the membrane from surface crazing and cracking. In addition, this coating should be maintained as needed to re-coat any areas that have blistered, peeled or worn through.
b. Granule-surfaced Firestone APP and SBS membranes do not normally need surface maintenance other than periodic inspection for contaminants, cuts or punctures. If areas of granular loss are discovered during inspection, these areas should be coated with Firestone AcryliTop or other Firestone-approved coating applied in accordance with Firestone specifications.
c. Gravel-surfaced Firestone BUR membranes do not normally need surface maintenance other than periodic inspection for contaminants or damage. If areas of gravel loss are discovered during inspection, gravel shall be reinstalled into hot asphalt to protect the surface of the membrane. Coatings on smooth surface BUR membranes shall be maintained as needed to re-coat any areas that have blistered, peeled or worn through.
d. Firestone EPDM and TPO roofing membranes do not normally need surface maintenance other than periodic inspection for contaminants, cuts or punctures. Occasionally, approved liquid roof coatings, such as Firestone AcryliTop, are applied to the surface of EPDM membranes in order to provide a lighter surface color. Such coatings do not need to be maintained to assure the performance of the underlying EPDM roof membrane, but some maintenance and re-coating may be necessary in order to maintain a uniform surface appearance.
e. Firestone Una-Clad metal roofing panels and trim do not normally need surface maintenance other than periodic inspection for contaminants or damage. In addition, periodic cleaning of the surface may be needed to remove dirt and maintain the aesthetic appearance of the coated metal. Simple washing with plain water using hoses or pressure spray equipment is usually adequate. If cleaning with agents other than water is contemplated, several precautions should be observed: (1) do not use wire brushes, abrasives, or similar cleaning tools which will mechanically abrade the coating surface, and (2) cleaning agents should be tested in an inconspicuous area before use on a large scale.
6. All metal work, including counter-flashings, drains, skylights, equipment curbs and supports, and other Firestone brand rooftop accessories should be properly maintained at all times. Particular attention should be paid to sealants at joints in metal work and flashings. If cracking or shrinkage is observed, the joint sealant should be removed and replaced with new sealant.
7. Any alterations to the roof, including but not limited to roof curbs, pipe penetrations, roof-mounted accessories, and tie-ins to building additions must be performed by a licensed Firestone Licensed Applicator and reported to Firestone.
Additional information and reporting forms for roof alterations are available at www.firestonebpco.com.
8. Should you experience a leak:
(a) Check for the obvious: clogged roof drains, loose counterflashings, broken skylights, open grills or vents, broken water pipes.
(b) Note conditions resulting in leakage. Heavy or light rain, wind direction, temperature and time of day that the leak occurs are all-important clues to tracing roof leaks. Note whether the leak stops shortly after each rain or continues to drip until the roof is dry. If you are prepared with the facts, the diagnosis and repair of the leak can proceed more rapidly.
(c) Contact Firestone Warranty Claims at 1-800-830-5612 as soon as possible...but please don't call until you are reasonably sure that the Firestone Roofing System is the cause of the leak.
Firestone feels that the preceding requirements will assist you, the building owner, in maintaining a watertight roof for many years. Your roof is an investment, and maintenance is essential to maximize your return on this important investment.
Submittal package prepared for Gary Brown Roofing Co., Page iii
September 02, 2015
GARY BROWN ROOFING COMPANY
4227 Triangle St
Mc Farland, WI 535589444
To Whom It May Concern:
Please be advised that GARY BROWN ROOFING COMPANY is a licensed Red Shield applicator in good standing with Firestone Building Products Company.
GARY BROWN ROOFING COMPANY is authorized with Firestone for EPDM effective 04/20/85, APP effective 04/20/85, ULTRAPLY effective 04/20/85, SBS/BUR effective 07/02/01 under license #03033.
Firestone is proud to include GARY BROWN ROOFING COMPANY into our family of Red Shield applicators.
If I may be of further assistance, please feel free to call my office.
Sincerely, Phil LaDuke
Director, Quality Assurance
9/2/2015
250 West 96th Street - Indianapolis, IN 46260
1-800-428-4442 * 1-317-575-7000 * FAX 1-317-575-7100
Submittal package prepared for Gary Brown Roofing Co., Page iv
1. Area 1- CG9124
Submittal package prepared for Gary Brown Roofing Co., Page 1
BUILDING PRODUCTS
PRE-INSTALLATION NOTICE
RubberGard EPDM/UltraPly 78+/UltraPly TPO
Start Date:
FBPCO No: (Firestone File Number)
STATUS:
Firestone License No:
Address:
Firestone Contractor (Firm Name):
E-Mail addressphone countryzipstate
Fax No.
city
Owner (company): Contact Name:
Owner Address:
state zip
Specifier Firm/Owner state zip
WARRANTY DATA The warranty will be printed using the information as submitted on this form.
INSTALLATION DATA
System / Construction / Decks / Insulation / Membrane Information
Building Name:
Building Address: zip cntry ph
Warranty Request
Roof Height Parapet Height
Roof Slope Increased Wind Speed Warranty
Warranty Length Membrane Warranty
Dimensions X
MPH
Note: Must be completed 2 weeks prior to start of project.
Pending
Pending verification
GARY BROWN ROOFING COMPANY
4227 Triangle St Mc Farland WI US
ANG Building 412
3110 Mitchell Street Madison WIstate 53704-2529 ph ph ph
US
cntry
115FW/LGC Wisconsin Air National Guard
3110 Mitchell Street
Madison WI 53704-2529 US
AK
Red Shield 20 Yr. No
No1/4 in. (6.4 mm)
System Type: Construction Type: Number of Decks:
03033
Adhered - EPDM
Roof Slope Other
Existing 1
September 14, 2015
(608) 838 - 0066 (608) 838 - 0508
535589444
Membrane Warranty Length
41000 40 12
NOTE: Only information entered in PIN is shown on this report
Warranted Sq. Ft.
Ground
Roughness
Viewable
Exposure Opening > 10 feet. Opening < 10 feet.
Vapor Retarder: Other
Hail Warranty No
Deck Type 1: Other:Steel Gauge 20
Number of Layers of Insulation: 3
Base Layer:
Attachment: Rate:Length / Type: App. Layout:
ISO 95+
None/Loose-laid Other:
Thickness Other Thickness2.0 in. (50.8 mm)
Attachment: Rate:Length / Type: App. Layout: Other:None/Loose-laid
Intermediate Layer: ISO 95+ Thickness Other Thickness1.5 in. (38.1 mm)
Attachment: Rate:Length / Type: App. Layout: Other:Firestone Fasteners 16 Per Board6 in (152.4 mm)/Heavy Duty Fastener
Top Layer: DensDeck™ Prime Thickness Other Thickness1/2 in. (25 mm)
Rate Surfacing Type:
Design Layout NO.:
Type:
Other:
Gauge:
Fasteners: Length:
None
EPDM NonRein. LSFR .060
Expected Foot Traffic:WindowCleaning Equipment:
Color:Membrane Information: Adhesive: Bonding Adhesive BA-2004 (T)
Invisiweld Att. Rate:
Above Membrane Components:
SkyScape System: SkyScape Warranty: PhotoVoltaic:None None
SunWave: Number Of
SunWaves:
No
Existing Roof Membrane:Existing Roof Construction: Complete Tear Off Other:
Edge Metal Information:
Firestone AnchorGard: No Firestone Coping: No Firestone Edging: No
Firestone UnaEdge: Firestone Coil or Flat Stock Metal:No Yes
Specification Requires Final Inspection: No TotalGard Maintenance Agreement: No
Sales rep pre-approval of any special considerations for this project: No
Additional Information:
Date: Submitted By:
I certify to the best of my knowledge the above information is accurate.Certification:
Forman Name:
Roof Accessibility: Ladder Length:
Kurt Knbole
Company: Gary Brown Roofing
Roof Hatch ARD with PIN
Reviewed by:
Tech Rep assigned is:
09/02/2015
Yes
Derek Westrum
Fax: 800-242-0504
Jesse Riesen -- 7000
Address: Phone: 800-428-4511250 West 96th Street
Indianapolis, IN 46260
Submittal package prepared for Gary Brown Roofing Co., Page 2
Submittal package prepared for Gary Brown Roofing Co., Page 3
Submittal package prepared for Gary Brown Roofing Co., Page 4
Submittal package prepared for Gary Brown Roofing Co., Page 5
Submittal package prepared for Gary Brown Roofing Co., Page 6
Submittal package prepared for Gary Brown Roofing Co., Page 7
TECHNICAL INFORMATION SHEET
Firestone Building Products 250 W. 96th Street, Indianapolis, IN 46260 Sales: (800) 428-4442 Technical (800) 428-4511 www.firestonebpco.com
S723-RFS-003
7.15.2013
Low-Slope Fire Retardant (LS FR) RubberGard™ EPDM Membrane
Preparation of Substrate:
1. Substrates must be clean, dry, smooth, and free of sharp edges, fins, loose or foreign materials, oil, grease, and other materials that may damage the membrane.
2. All roughened surfaces that can damage the membrane shall be repaired as specified to offer a smooth substrate.
3. All surface voids greater than 1/4" (6.3 mm) wide shall be properly filled with an acceptable fill material.
Method of Application:
1. RubberGard Non-Reinforced FR EPDM Membrane must be installed in accordance with current RubberGard specifications, details and workmanship requirements.
Storage:
Store away from sources of punctures and physical damage.
Assure that structural decking will support the loads incurred by material when stored on rooftop. The deck load limitations should be specified by the project designer.
Store away from ignition sources as membrane will burn when exposed to open flame.
Precautions:
Take care when moving, transporting, handling, etc. to avoid sources of punctures and physical damage.
Isolate waste products, such as petroleum products, greases, oils (mineral and vegetable) and animal fats from the RubberGard membrane.
Refer to Material Safety Data Sheets (MSDS) for safety information.
¹Available sizes vary by product. Contact your Firestone Customer Service Representative for availability and packaging information.
Packaging: Widths¹ Lengths Weight
.045” LS-FR 7.5’ (2.3 m) 100’ (30.5 m) 0.31 lb/sf (1.5 kg/m²) 10’ (3.05 m) 100’ (30.5 m) 16.7’ (5.09 m)
20‘ (6.1 m) 30‘ (9.14 m) 40‘ (12.19 m) 50‘ (15.24 m)
100’ (30.5 m) 100’ (30.5 m) 100’ (30.5 m) 100’ (30.5 m)
.060” LS-FR 7.5’ (2.3 m) 100’ (30.5 m) 0.43 lb/sf (2.1 kg/m²) 10’ (3.05 m) 100’ (30.5 m) 16.7’ (5.09 m)
20‘ (6.1 m) 30‘ (9.14 m) 40‘ (12.19 m) 50‘ (15.24 m)
100’ (30.5 m) 100’ (30.5 m) 100’ (30.5 m)
Description:
Firestone FR RubberGard™ EPDM is a non-reinforced, cured, single-ply roofing membrane that can be used in ballasted, fully adhered and mechanically attached systems.
TIS #103
Submittal package prepared for Gary Brown Roofing Co., Page 8
Firestone Building Products 250 W. 96th Street, Indianapolis, IN 46260 Sales: (800) 428-4442 Technical (800) 428-4511 www.firestonebpco.com
S723-RFS-003
7.15.2013
Compliance:
Post Consumer Recycled Content: 0% Pre Consumer Recycled Content: 0% Manufacturing Location: Prescott, AR CCMC 13266-L
Physical Properties: ASTM Standard Units Performance Minimum
Typical Values 45 mil
Typical Values 60 mil
Thickness, minimum Sheet-overall
D 412 In. (mm) 0.0405 (1.016)
0.0504 (1.372)
0.0405 (1.092) 0.059 (1.499)
Tensile Strength, minimum D 412 (Die C) psi(MPa) 1305 (9.0) 1435 (9.9) 1454 (10.0) Elongation, Ultimate, minimum D 412 (Die C) % 300 450 622 Tensile set, maximum D 412, Method A (Die C) % 10 5 2.18 Tear Resistance, minimum D 624 (Die C) Lbf/in (kN/m) 159
26.3 33.2
38.4
Brittleness point, maximum D 2137 °F(°C) -49(45) -62(-52) -49(-45) Ozone resistance, no cracks D 1149 - - Pass Pass Heat Aging: D 573
Tensile Strength, min. D 412 (Die C) psi(MPa) 1205(8.3) 1425(9.8) 1490(10.3) Elongation, ultimate, min.
Tear resistance, min.
Linear dimensional change, maximum Water absorption, max, mass % Factory Seam Strength, minimum
Weather Resistance:
Visual inspection PRFSE, minimum Elongation, ultimate, min
D 412
D 624
D 1204 D 471 D 816 Method B
(Modified)
D 518 D 518 D 412 (Die C)
Lbf/in (kN/m) Lbf/in (kN/m)
21.9 ±1.0 +8,-2 50 (8.8) or Sheet Failure
Pass
31.5 -0.5 +1.8
31.3 -.32 +1.51
RubberGard LS-FR membrane meets or exceeds the minimum requirements set forth by ASTM D 4637 for Type I non-reinforced EPDM single-ply roofing membranes.
Please Contact your Firestone Technical Coordinator at 1-800-428-4511 for further information.
This sheet is meant to highlight Firestone products and specifications and is subject to change without notice. Firestone takes responsibility for furnishing quality materials which meet published Firestone product specifications. Neither Firestone nor its representatives practice architecture. Firestone offers no opinion on and exp ressly disclaims any responsibility for the soundness of any structure. Firestone accepts no liability for structural failure or re sultant damages. Consult a competent structural engineer prior to installation if the structural soundness or structural ability to properly support a planned installation is in question. No Firestone representative is authorized to vary this disclaimer.
Submittal package prepared for Gary Brown Roofing Co., Page 9
EPDM Bonding Adhesive BA-2004(T)
Firestone Building Products | Sales: (800) 428-4442 | Technical (800) 428-4511 | www.firestonebpco.com
S723-RFS-054 TIS # 817 03/06/2014
Firestone EPDM Bonding Adhesive BA-2004 (T) is a solvent based contact adhesive designed specifically for bonding
Firestone RubberGard™ membranes and flashings to ISO 95+™ Insulation, wood, metal, masonry and other acceptable substrates.
1. Surfaces to receive EPDM Bonding Adhesive BA-2004 (T) shall be clean, smooth, dry, free of sharp edges, loose and foreign materials, oil, grease, and other contaminants. Sweep the mating surface of the membrane with a stiff broom to remove excess dusting agent, if present, or other contaminants from the mating surface.
2. Stir the adhesive thoroughly before and during use, achieving a uniform mix with no sediment on the bottom and no marbling evident.
3. Apply adhesive at about the same time to both the exposed underside of the sheet and the substrate to allow approximately the same flash-off time.
4. EPDM Bonding Adhesive BA-2004(T) may be applied with a solvent-resistant paint roller or mechanical equipment designed to apply flammable solvent based adhesives.
5. Apply by rolling the adhesive on both mating surfaces. EPDM Bonding Adhesive BA-2004(T) should be applied evenly so as to avoid globs or puddles.
6. As an option, spray EPDM Bonding Adhesive BA-2004(T) and back-roll the adhesive uniformly and evenly with a solvent-resistant paint roller. Care must be taken not to apply EPDM Bonding Adhesive BA-2004(T) over any area that will later be cleaned and spliced to another sheet or flashing.
7. Allow EPDM Bonding Adhesive BA-2004(T) to flash off until tacky. Touch the EPDM Bonding Adhesive BA-2004(T) surface with a clean, dry finger to be certain that the adhesive is dry and does not stick or string. While pushing straight down to check for stringing, also push forward on the adhesive at an angle to ensure that the adhesive is ready (flashed off) throughout its thickness. If either motion exposes wet or stringy adhesive when the finger is lifted, then it is not ready for mating. Flash-off time will vary depending on ambient air conditions.
8. Starting at the fold, roll the previously coated portion of the sheet into the coated substrate slowly and evenly so as to minimize wrinkles.
9. To ensure proper contact, compress the bonded half of the sheet to the substrate with a stiff push broom using heavy pressure.
Store in original unopened containers at temperatures between 60 °F (15.6 °C) and 80 °F (26.7 °C) until ready for use.
For optimum results, rotate your stock to ensure stored material has not exceeded the shelf life of one year.
Shelf life of one year can be expected if stored in original sealed container at temperatures between 60 °F (15.6 °C) and 80 °F (26.7 °C). If exposed to lower temperatures, restore to room temperature prior to use.
Shelf life will be shortened if exposed to elevated temperatures. Rotate stock to insure stored material will not go beyond the shelf life of one year.
Item Number
W563587052
Product Information
Submittal package prepared for Gary Brown Roofing Co., Page 10
Firestone Building Products | Sales: (800) 428-4442 | Technical (800) 428-4511 | www.firestonebpco.com
Flammable. Keep away from fire and open flame and other possible ignition sources during storage and use. Do not smoke when using.
Harmful or fatal if swallowed.
Avoid prolonged inhalation.
Avoid prolonged contact with skin. Gloves should be worn (OSHA approved).
Avoid eye contact by wearing safety glasses with side shields or safety goggles.
For professional use only.
Keep out of reach of children.
Thinning is not allowed.
Do not use for splicing.
Do not use with TPO.
Use only in well ventilated areas.
Cover tightly when not in use.
Review Safety Data Sheet specified on the Bonding Adhesive container label.
Recommended cleaner is Firestone Splice Wash SW-100 Cleaner.
LEED® Information:
Post Consumer Recycled Content: 0% Post Industrial Recycled Content: 0% Manufacturing Location: South Bend, IN
Base: A blend of Polychloroprene and SBR rubbers
Color: Yellow
Solvents: A blend of Acetone, Hexane, Toluene and Xylene
Viscosity: 3,300-3,800 cps, with R.V.F. #3 spindle @ 10 rpm
Weight/Gallon: 6.6-7.4 lb/gal
Specific Gravity: 0.7909-0.8868
V.O.C. Content: 5.282 lb/gal (633 g/L)
Pail: 5 gal (18.9 L)
Weight: 41 lb (18.6 kg)
Coverage:
A coverage rate of 45 - 60 ft²/gal (1.10 – 1.47 m²/L) may be obtained depending on the substrate. Some insulation surfaces are more uneven and porous and will result in a lower coverage rate while smooth non-porous substrates will result in higher coverage rates. Rates are based on roller application to both mating surfaces.
Very porous substrates (rough wood, concrete block) may require two coats of EPDM Bonding Adhesive BA-2004(T), to ensure proper adhesion. This can be determined by adhering a small piece of membrane to the porous substrate to verify the bonding strength.
substrate. Some insulation surfaces are more uneven and porous and will result in a lower coverage rate while smooth non-porous substrates will result in higher coverage rates. Rates are based on roller application to both mating surfaces.
Very porous substrates (rough wood, concrete block) may require two coats of Bonding
Units per Pallet: 45 – 5 gal pails
Typical Properties
Packaging Data
Submittal package prepared for Gary Brown Roofing Co., Page 11
Firestone Building Products | Sales: (800) 428-4442 | Technical (800) 428-4511 | www.firestonebpco.com
Approved Power Application Equipment:
Garlock 25ST Roller Boss Power Roller
4 hp Honda Engine,4 CFM Compressor,25 gal pressurized supply tank (20 gal for material; 60-80 psi), up to 100 psi rating, 2 – ¾" x 30' supply hoses with swivels, 2 – 18" roller head assemblies
Garlock 2120 Commander Sprayer
18 hp Kohler Engine,4500 psi Rating, 5 gallon per minute flow, 1200 psi pressure (minimum), Pump Displacement 45:1, GPM Rating: up to 5 GPM, ½" x 100' hose, 2" Intake pipe with screen, 5 or 55 gal drum containers, Graco Spray Tips:
.023 to .031 diameter hose
Garlock Twin Gun Airless Sprayer
6.5 hp Honda Engine, 3000 psi Rating, Pump Displacement 30:1, GPM Rating: up to 1 gpm, Up to 400’ of single ½" diameter hose, Up to 200' of dual ½" diameter hose, ¾" Intake pipe with screen, 5 or 55 gal drum containers, Bulk tank containers, Graco Spray Tips: .019 to .025 diameter hose (1850 psi operating pressure)
Graco Spray Equipment:
P70EC4-70 – 70:1 Xtreme Sprayer Package w/Heavy Duty car, Hopper package, w/NXT motor and Data Track, Xtreme-
Duty high pressure hose, 3/8" x 50', 7250 psi, with ¼" x 6' whip hose, XTR-7 applicator with XHD821-825 tips.
Please contact your Building System Advisor at 1-800-428-4511 for further information.
This sheet is meant to highlight Firestone products and specifications and is subject to change without notice. Firestone takes responsibility for furnishing quality materials which meet published Firestone product specifications. Neither Firestone nor its representatives practice architecture.
Firestone offers no opinion on and expressly disclaims any responsibility for the soundness of any structure. Firestone accepts no liability for structural failure or resultant damages. Consult a competent structural engineer prior to installation if the structural soundness or structural ability to properly support a planned installation is in question. No Firestone representative is authorized to vary this disclaimer.
Submittal package prepared for Gary Brown Roofing Co., Page 12
Firestone Building Products 250 W. 96th Street, Indianapolis, IN 46260 Sales: (800) 428-4442 Technical (800) 428-4511 www.firestonebpco.com
S723-RFS-117 2.6.2012
QuickSeam™ Flashing
ITEM NUMBER:
5” x 100’ W56RAC1615
Description:
QuickSeam Flashing is a semi-cured EPDM flashing laminated to cured seam tape. QuickSeam Flashing is used to flash gravel stops and other details as specified in the Firestone Specifications and Details.
1. Use QuickPrime™ Plus and QuickScrubber™ or QuickScrubber Plus pad and handle to clean and prime membrane and metal mating surfaces.
2. Refer to Firestone Specifications and Details.
3. Refer to application instructions for specifics: Technical Database, www.firestonebpco.com.
Store in original unopened containers indoors at temperatures between 60 °F (15.6 °C) and 80 °F (26.7 °C).
Do not store on roof in direct sunlight or at temperatures above 80 °F (26.7 °C).
When exposed to lower temperatures; restore to room temperature prior to use.
Shelf life of one year can be expected when stored in original container at temperatures between 60 °F (15.6 °C) and 80 °F (26.7 °C).
Shelf life will be shortened if exposed to elevated temperatures.
Refer to Material Safety Data Sheet (MSDS).
QuickSeam Flashing is semi-cured. Do not stretch.
Compliance:
Manufacturing Location: Prescott, AR
NOTE: QuickScrubber and/or QuickScrubber Plus pads and handles are included in each carton. Quantities vary depending on the QuickSeam product.
Physical Properties: Value
QuickSeam Tape:
Base Color Solvents Solids Cured State Thickness Width Length
Rubber Polymers Black None 100% Cured 0.045” (1.14 mm) ± 0.005” (0.13 mm) 5-1/4” (133.3 mm) + o, - 1/16”
Please Contact your Firestone Roof Systems Advisor at 1-800-428-4511 for further information.
This sheet is meant to highlight Firestone products and specifications and is subject to change without notice. Firestone takes responsibility for furnishing quality materials which meet published Firestone product specifications. Neither Firestone nor its representatives practice architecture. Firestone offers no opinion on and expressly disclaims any responsibility for the soundness of any structure. Firestone accepts no liability for structural failure or resultant damages . Consult a competent structural engineer prior to installation if the structural soundness or structural ability to properly support a planned installation is in question. No Firestone representative is authorized to vary this disclaimer.
Packaging:
Roll
Pallet
5” (76.3 mm) x 100’ (30.48 m) roll, 2 rolls per carton Rolls may consist of two separate sections of QuickSeam Flashing to make 100’ (30.5 m) total length.
36 cartons per pallet
TIS #1402
EPDM Flashing:
Base Color Solvents Solids Cured State Thickness Width Length
EPDM
None 100% Semi-Cured 0.045” (1.14 mm) ± 10% 5” (133.3 mm) + 0, - 1/8”
Submittal package prepared for Gary Brown Roofing Co., Page 13
Firestone Building Products 250 W. 96th Street, Indianapolis, IN 46260 Sales: (800) 428-4442 Technical (800) 428-4511 www.firestonebpco.com
S723-RFS-127 2.13.2012
QuickPrime™ Plus LVOC
ITEM NUMBER: W563587043
Description:
QuickPrime Plus LVOC is designed to clean and prime RubberGard™ EPDM membrane and RubberGard EcoWhite™ EPDM prior to application of QuickSeam™ products where required by Firestone Specifications and Details.
QuickPrime Plus LVOC must be applied with a QuickScrubber™ or QuickScrubber Plus pad and handle when preparing RubberGard membrane to receive QuickSeam Tape products. It may also be used to clean membrane prior to the application of Firestone Lap Sealant LVOC.
1. Splice surfaces must be clean, dry, and free of foreign materials and excess dusting agent. Clean with broom or rags to remove contaminates.
2. Stir QuickSeam Plus LVOC thoroughly before and during use. Apply QuickPrime Plus LVOC using the QuickScrubber or QuickScrubber Plus pad and handle.
3. Use back and forth strokes with heavy pressure along the length of the splicing area, until membrane surfaces become black in color with no streaking or puddling.
4. Allow the QuickPrime Plus LVOC surfaces to flash off completely according to the touch-push test (usually less than 30 minutes) before applying QuickSeam products or Lap Sealant LVOC.
5. Complete QuickSeam product installation or Lap Sealant LVOC application in accordance with Firestone Specifications and Details.
Store in original unopened containers indoors at temperatures between 60 °F (15.6 °C) and 80 °F (26.7 °C).
Do not store on roof in direct sunlight or at temperatures above 80 °F (26.7 °C).
When exposed to lower temperatures; restore to room temperature prior to use.
Shelf life of one year can be expected when stored in original container at temperatures between 60 °F (15.6 °C) and 80 °F (26.7 °C).
Thinning is not allowed.
Flammable. Keep away from fires (open flame) and other possible ignition sources during storage and use. Do not smoke when using.
Use only in well-ventilated areas.
Use of neoprene or nitrile gloves and eye protection with side shield is recommended.
Use only in conjunction with QuickScrubber or QuickScrubber Plus. Do not apply with rollers, brushes or rags.
Mix thoroughly before and during use.
TIS #1412
Submittal package prepared for Gary Brown Roofing Co., Page 14
Firestone Building Products 250 W. 96th Street, Indianapolis, IN 46260 Sales: (800) 428-4442 Technical (800) 428-4511 www.firestonebpco.com
S723-RFS-127 2.13.2012
Base Color Solvents Percent Solids Viscosity Weight (Nominal) Specific Gravity Flash Point V.O.C. Content
Synthetic Rubber Polymers Black Hydrocarbon and Halogenated Solvents
9-10% Very thin, free flowing
9.95 lb/gal (1.14 kg/L) 1.146 57.2°F (14°C) Not to exceed 2.1 lb/Gal (250 g/L)
This sheet is meant to highlight Firestone products and specifications and is subject to change without notice. Firestone takes responsibility for furnishing quality materials which meet published Firestone product specifications. Neither Firestone nor its representatives practice architecture. Firestone offers no opinion on and expressly disclaims any responsibility for the soundness of any structure. Firestone accepts no liability for structural failure or resultant damages. Consult a competent structural engineer prior to installation if the structural soundness or structural ability to properly support a planned installation is in question. No Firestone representative is authorized to vary this disclaimer.
Packaging: Weight
Container:
3 Gallon (11.4 liter) pail
75-3 Gallon pails/pallet
1658.25 lb/ 753.35 kg
Coverage Rates:
General
150 - 225 square feet per gallon (3.68-5.52 square meter per liter) for a one side application
Submittal package prepared for Gary Brown Roofing Co., Page 15
Firestone Building Products 250 W. 96th Street, Indianapolis, IN 46260 Sales: (800) 428-4442 Technical (800) 428-4511 www.firestonebpco.com
S723-RFS-123 2.9.2012
QuickSeam™ Corner Flashing
ITEM NUMBER: W56RAC1646
Description:
QuickSeam Corner Flashing consists of Firestone FormFlash™ factory laminated to QuickSeam Tape. It is 8.5” (216 mm) in diameter and is designed to flash inside and outside corners of RubberGard™ EPDM roof systems.
1. Use QuickPrime™ Plus and a QuickScrubber™ or QuickScrubber Plus pad and handle to clean and prime mating surfaces.
2. When cloudy conditions below 60 °F (15.6 °C) occur, use heat guns (without ignition sources) to heat
QuickSeam Corner Flashing. This will ensure good formability of the QuickSeam Corner Flashing to the primed substrate.
3. On sunny days less that 70 °F (21.1 °C), place QuickSeam Corner Flashing on roof (prior to application) with flashing side up to allow
QuickSeam Corner Flashing to warm to ensure good formability.
4. On sunny days greater than 70 °F (21.1 °C), place QuickSeam Corner Flashing on roof (prior to application) with release paper side up to prevent QuickSeam Corner Flashing from gaining too much heat and to ensure good formability.
5. Refer to Firestone Specifications and Details. Refer to application instructions for specifics: Technical Database, www.firestonebpco.com.
Storage:
Store in original unopened containers indoors at temperatures between 60 °F (15.6 °C) and 80 °F (26.7 °C).
Do not store on roof in direct sunlight or at temperatures above 80 °F (26.7 °C).
When exposed to lower temperatures; restore to room temperature prior to use.
Shelf life of one year can be expected when stored in original container at temperatures between 60 °F (15.6 °C) and 80 °F (26.7 °C).
Manufacturing Location: Prescott, AR
Base Color Solvents Solids Cured State Thickness
Rubber Polymers
None 100% Cured 0.025” (0.64 mm) ± 0.005” (0.127 mm)
This sheet is meant to highlight Firestone products and specifications and is subject to change without notice. Firestone takes responsibility for furnishing quality materials which meet published Firestone product specifications. Neither Firestone nor its representatives practice architecture. Firestone offers no opinion on and expressly disclaims any responsibility for the soundness of any structure. Firestone accepts no liability for structural failure or resultant damages . Consult a competent structural engineer prior to installation if the structural soundness or structural ability to properly support a planned installation is in question. No Firestone representative is authorized to vary this disclaimer.
Packaging:
Units
20 units per carton 100 cartons per pallet
TIS #1408
FormFlash:
Base Color Solvents Solids
None 100% Uncured 0.065” (1.59 mm) ± 0.005” (0.127mm)
Submittal package prepared for Gary Brown Roofing Co., Page 16
Firestone Building Products 250 W. 96th Street, Indianapolis, IN 46260 Sales: (800) 428-4442 Technical (800) 428-4511 www.firestonebpco.com
S723-RFS-124 2.9.2012
QuickSeam™ Pipe Flashing
ITEM NUMBER: W563581063
Description:
QuickSeam Pipe Flashings are specifically designed to be used in roofing applications for flashing of round penetrations. QuickSeam Pipe Flashings will fit various penetrations and must be cut to correct pipe diameter before installation.
QuickSeam Pipe Flashings may be used to flash penetrations for both RubberGard™ EPDM as well as APP and SBS Modified Bitumen systems.
1. Clean the Rubbergard membrane using QuickPrime™ Plus and a QuickScrubber™ or QuickScrubber Plus pad and handle to remove all dusting agents, dirt and other contaminants that will affect the finished bond.
2. Allow to dry according to the touch-push test.
3. Cut along the top edge of the ring on the QuickSeam Pipe Flashing corresponding to the size of the pipe.
4. Remove the release paper.
5. Install the pipe flashing and roll the flange with a silicone hand roller.
6. Install the clamping ring and Lap Sealant per Firestone Specifications and Details.
7. Install per specific requirements as outlined on the QuickSeam Pipe Flashing Technical Information Sheet located in the Firestone
Asphalt Technical Manual.
Store in original unopened containers indoors at temperatures between 60 °F (15.6 °C) and 80 °F (26.7 °C).
Do not store on roof in direct sunlight or at temperatures above 80 °F (26.7 °C).
When exposed to lower temperatures; restore to room temperature prior to use.
Shelf life of…
This is the start of the file's text. The full file is on GovTribe.