Amend 0001 Revised drawings CD101 C101 C102 C103 ED101 ES101 E602.pdf

PDF 3 MB Posted

Attached to
Munitions Storage Area (MSA) Expansion Federal contract opportunity
Solicitation number
W50S87-21-B-5003
Issued by
Department of the Army North Carolina Army National Guard

About this file

This solicitation is for a munitions storage area (MSA) expansion project at the North Carolina Army National Guard facility in Charlotte, North Carolina. Key details include:

  • The project scope includes construction of a new 15' x 20' munitions and explosives (M&E) storage magazine building, a 44' x 40.5' storage magazine building, and a 44'8" x 21'4" administration building.

  • A pre-bid conference/site visit will be held on May 27, 2021 at 1:00pm EDT for interested bidders to register for and attend. Bids are due by the date specified in the solicitation.

  • The soliciting agency is the Department of the Army North Carolina Army National Guard. Construction drawings, specifications and other attachments provide additional details on the project requirements.

  • The opportunity type is a solicitation seeking bids from contractors to complete the MSA expansion project.

View the file

Other files for this federal contract opportunity

Other files attached to Munitions Storage Area (MSA) Expansion, newest first.
File Type Posted
OF 1419 - Abstract of offers - MSA Expansion.pdf PDF
Bid Opening Sign in.pdf PDF
Standard epoxy primer and binder.pdf PDF
Amend 0002 Revised drawings CD101 C101 C102 C103 S101 S102 S103 S601 ED101 ES101 E602.pdf PDF
Questions and Answers2 MSA Expansion.pdf PDF
W50S87-21-B-5003-0002.pdf PDF
Static control epoxy coating.pdf PDF
ARMAG S73.pdf PDF
Questions and Answers1 MSA Expansion.pdf PDF
W50S87-21-B-5003-0001.pdf PDF
ARMAG S74.pdf PDF
PreBidSlides W50S87-21-B-5003.pdf PDF
Pre-bid sign in W50S87-21-B-5003.pdf PDF
Solicitation Attachment 7 - Pre-Bid Conference and Site Visit - Bid Drop-Off Map.pdf PDF
Solicitation Attachment 8 - Brand name justification - MSA - Alerton_Redacted.pdf PDF
Solicitation Attachment 9 - Brand name justification - MSA - Best - Door hardware_Redacted.pdf PDF
Solicitation Attachment 7 - Pre-Bid Conference and Site Visit - Bid Drop-Off Map.pdf PDF
Solicitation Attachment 1 - Drawings Vol 1 of 2 - General - Civil - Architectural - Structural.pdf PDF
Solicitation Attachment 11 - Brand name justification - MSA - Monaco_Redacted.pdf PDF
Solicitation Attachment 4 - Statement of Work.pdf PDF
Solicitation Attachment 3 - Specifications.pdf PDF
Solicitation Attachment 2 - Drawings Vol 2 of 2 - Mechanical - Plumbing - Fire Protection - Electrical.pdf PDF
W50S87-21-B-5003.pdf PDF
Solicitation Attachment 13 - 145 AW Contractor Security Guide.pdf PDF
Solicitation Attachment 6 - Visitor Request Worksheet.pdf PDF
Solicitation Attachment 12 - 145 AW Contractor Safety Guide.pdf PDF
Solicitation Attachment 10 - Brand name justification - MSA - Interior and Exterior Finishes_Redacted.pdf PDF
Solicitation Attachment 5 - Geotechnical Report.pdf PDF
Show all 28

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SAWCUT AND REMOVE PAVEMENT FOR

TRENCH EXCAVATION FOR UTILITY SERVICES

CLEAR AND GRUB WOODED AREA

SAWCUT AND REMOVE PAVEMENT FOR

MUNITIONS STORAGE MAGAZINE CONSTRUCTION

REMOVE SECTION OF ABANDONED WATER

MAIN FOR RELOCATION WORK

MILLING OF SURFACE COURSE PAVEMENT, 2" DEPTH

REMOVE ELECTRICAL AND COMMUNICATION LINES, REMOVE

CONNECTIONS TO EXISTING STRUCTURES AND ABANDON

CONDUITS IN PLACE. REMOVE EXISTING CONDUITS AT

UTILITY CONFLICTS. ABANDON CONDUITS IN PLACE BY

CUTTING AND CAPPING AND FILLING WITH FLOWABLE FILL.

REFER TO DRAWING ED101 FOR ADDITIONAL INFORMATION

EXISTING BUILDING NO. 74 TO BE RAZED

DISCONNECT EXISTING 6"Ø FIRE WATER

SERVICE AND CAP. DISCONNECT EXISTING 2"Ø

POTABLE WATER SERVICE FOR RECONNECTION

D

WV

W

T

T

S

W

ICV

D

EV

E

E

E

S

S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S

S

U

T

PARCEL 11510205

CITY OF CHARLOTTE

PARCEL 11510205

CITY OF CHARLOTTE

PARCEL 11521103A

CITY OF CHARLOTTE

PARCEL 11521103A

CITY OF CHARLOTTE

WV

WV

WV

WV

S S

S S

S S

S S

S S

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W W

W W

W

W

W

W

W

W

W

W

W

W

W

E

E

E

E

E

E

E

E

E

E E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E E

E

E

E

E

E

E

E

TEMPORARY SILT FENCE FOR SOIL

EROSION CONTROL

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

TREELINE AND LIMITS OF CLEARING

OPTION 1: REMOVE EXISTING PAVEMENT PARKING

STRIPING WITHOUT DAMAGING EXISTING PAVEMENT

WITH WATER BLASTING OR APPROVED EQUAL

OPTION 1: EXCAVATE AND REMOVE

TOPSOIL AND SUBGRADE FOR PARKING

EXPANSION AND FOR SIDEWALK EXTENSION

SAWCUT AND REMOVE PAVEMENT FOR

TRENCH EXCAVATION FOR UTILITY SERVICES

S

S

S

S

S S

S S

S

S

S

S

S

S

SAWCUT AND REMOVE PAVEMENT FOR TRENCH

EXCAVATION FOR ELECTRICAL SERVICE

DISCONNECT AND ABANDON EXISTING COMMUNICATION

SERVICE. REMOVE CONDUIT CONNECTIONS TO EXISTING

STRUCTURES. ABANDON EXISTING CONDUITS BY CUTTING

AND CAPPING AND FILLING WITH FLOWABLE FILL.

DISCONNECT EXISTING SANITARY SERVICE AND CAP

ABANDON EXISTING COMMUNICATION SERVICE AND

REMOVE CONNECTIONS TO EXISTING STRUCTURES.

ABANDON IN PLACE BY CUTTING AND CAPPING

CONDUITS AND FILLING WITH FLOWABLE FILL.

REMOVE (8) BOLLARDS FOR MUNITIONS

STORAGE MAGAZINE CONSTRUCTION

REMOVE ELECTRICAL EQUIPMENT AND (4) BOLLARDS

FOR CONSTRUCTION OF ELECTRICAL EQUIPMENT. REFER

TO DRAWING ED101 FOR ADDITIONAL INFORMATION

SAWCUT AND REMOVE PAVEMENT FOR

TRENCH EXCAVATION FOR ELECTRICAL

AND COMMUNICATION SERVICE

REMOVE CONCRETE PAD FOR MUNITIONS

STORAGE MAGAZINE CONSTRUCTION

REMOVE PORTION OF CONCRETE SLAB FOR M&I

MAGAZINE CONSTRUCTION. SAW CUT

CONCRETE PRIOR TO REMOVAL

EXISTING STEEL BUILDING NOS. 71 AND 73 TO BE RAZED

EXISTING PAVEMENT TO BE REMOVED

WITHIN BUILDING LIMITS

TEMPORARY SILT FENCE FOR SOIL EROSION

CONTROL

OPTION 1 LIMIT OF PAVEMENT REMOVAL

OPTION 1: EXISTING PAVEMENT TO

BE REMOVED OUTSIDE OF

BUILDING LIMITS

SAWCUT AND REMOVE PAVEMENT FOR TRENCH

EXCAVATION FOR UTILITY SERVICES. REFER TO

DRAWING ED101 FOR ADDITIONAL INFORMATION

SCALE: 1" = 30'

60300

SCALE: 1" = 30'

DEMOLITION SITE PLAN

D

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

April 5, 2021

398570

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

DMR

P r o j e c t

N o

F

J R

P

C h a r l o t t e

A

N G

B a s e

C

D I A

N

C

N o r t h

C r o l i n a

A i r

N a t i o n a l

G u a r d

C

B

A

D

C

B

A

54321

1 W oo d A ve S ou th

Ise lin

, N J 0

-4

3.3

.34

| m ott ma c.c om

M

IN

UT

EM

AN

W

AY

CH

AR

LO

TT

E, N

C

C

C o n v e r s i o n

C

M

S A

E x p a n s i o n

SHEET OF 53

06/08/2021MV FEEDER & CONDUIT1

VICINITY MAP

(NOT TO SCALE)

W

T

LEGEND

S

WV

SIGN

WATER METER

WATER VALVE

HYDRANT

SANITARY SEWER MANHOLE

TELEPHONE PEDESTAL

MONITORING WELL

UTILITY POLE

LIGHT POLE

GUY WIRE

DROP INLET

RCP REINFORCED CONCRETE PIPE

U

E

W

T

D STORM DRAINAGE MANHOLE

ELECTRIC BOX

EXISTING BOLLARD

MISC. UTILITY BOX

IRRIGATION CONTROL VALVE

BFP BACKFLOW PREVENTER

TBM TEMPORARY BENCHMARK

I-85

SITE

Exit

10A

I

Exit

U S

H W

Y

/7

W ilk in s o n B lv d

B i l l y

G r a h a m

P k w y

M o r r i s

F e l d

D r s t F li g h t

D r

M i n u t e m a n

W a y

M in u t e m a n

W a y

EMERGENCY SHUT-OFF VALVE

WATER FAUCET

GATE TELEPHONE

HAZARDOUS WASTE SATELLITE

CD101

TYPE B-3 SUBMISSION

DEMOLITION SITE PLAN

LP

LP

LP

D W

G

N

A M

E

C

U

S E

R S

V

O E

A

P P

D A

T A

L O

C A

L P

R O

J E

C T

W I S

E W

O R

K D

I R

M

O T

T U

S E

P

W D

M S

N

C A

N G

M

S A

B

R

E S

U B

D

W

V

E

D

A T

E

M

Y

V

O E

P

L O

T

D

A T

E

NOTES:

1. ALL MATERIAL SHALL BE PROPERLY DISPOSED OF AT AN APPROVED OFF-SITE LOCATION IN

ACCORDANCE WITH ALL FEDERAL, STATE, AND COUNTY AND MUNICIPAL REGULATIONS.

2. CONTRACTOR SHALL PROVIDE LEGIBLE, CLEAR COPIES OF ALL DISPOSAL TICKETS, WASTE

MANIFESTS, BILLS OF LADING, CHAINS OF CUSTODY, ETC. TO THE GOVERNMENT.

3. SEE ELECTRICAL DRAWINGS FOR ADDITIONAL TRENCHING LOCATIONS FOR CONDUITS AND

DUCT BANKS.

OVERHEAD UTILITIES

SS SANITARY SEWER LINE

W W WATER LINE

STORM SEWER LINE

GAS SERVICE LINE

COMMUNICATION LINE

TEMPORARY SILT FENCE

E ELECTRIC LINE

GAS LINE

CONSTRUCTION PHASING:

STAGE 1: CONSTRUCTION OF ADMINISTRATION BUILDING AND REQUIRED DEMOLITION WITHIN

ADMINISTRATION BUILDING EXTENTS.

STAGE 2: CONSTRUCTION OF TEMPORARY STORAGE SITE.

STAGE 3: DEMOLITION OF EXISTING BUILDINGS AND CONSTRUCTION OF 15' X 20' M&I MAGAZINE

AND CONSTRUCTION OF 44' X 40.5' STORAGE MAGAZINE.

STAGE 4: DECONSTRUCT TEMPORARY STORAGE SITE.

BOLLARD

AutoCAD SHX Text

CATCH BASIN RIM:656.93'

AutoCAD SHX Text

CATCH BASIN RIM:656.81'

AutoCAD SHX Text

CATCH BASIN RIM:659.95'

AutoCAD SHX Text

CATCH BASIN RIM:659.96'

AutoCAD SHX Text pavement edge

AutoCAD SHX Text pavement edge

AutoCAD SHX Text back of curb

AutoCAD SHX Text back of curb

AutoCAD SHX Text fence line

AutoCAD SHX Text

MINUTEMAN WAY

AutoCAD SHX Text Gate

AutoCAD SHX Text Gate

AutoCAD SHX Text Sectionalizer

AutoCAD SHX Text

MW

AutoCAD SHX Text Transformer

AutoCAD SHX Text Vault

AutoCAD SHX Text

BFP

AutoCAD SHX Text

EXISTING BUILDING

AutoCAD SHX Text

EXISTING BUILDING

AutoCAD SHX Text

FFE:689.71'

AutoCAD SHX Text asphalt

AutoCAD SHX Text asphalt

AutoCAD SHX Text asphalt

AutoCAD SHX Text asphalt

AutoCAD SHX Text asphalt

AutoCAD SHX Text asphalt

AutoCAD SHX Text concrete

AutoCAD SHX Text Concrete Sidewalk

AutoCAD SHX Text Concrete Sidewalk

AutoCAD SHX Text Concrete Sidewalk

AutoCAD SHX Text pavement edge

AutoCAD SHX Text pavement edge

AutoCAD SHX Text pavement edge

AutoCAD SHX Text pavement edge

AutoCAD SHX Text pavement edge

AutoCAD SHX Text pavement edge

AutoCAD SHX Text concrete

AutoCAD SHX Text concrete

AutoCAD SHX Text concrete

AutoCAD SHX Text concrete

AutoCAD SHX Text Fence line

AutoCAD SHX Text Fence line

AutoCAD SHX Text Tree line

AutoCAD SHX Text Tree line

AutoCAD SHX Text Tree line

AutoCAD SHX Text Tree line

AutoCAD SHX Text 10" Oak

AutoCAD SHX Text 10" Oak

AutoCAD SHX Text 10" Oak

AutoCAD SHX Text gravel

AutoCAD SHX Text

TBM FLANGE BOLT ON HYDRANT ELEV.:688.83'

AutoCAD SHX Text Curbing

AutoCAD SHX Text Curbing

AutoCAD SHX Text Curbing

AutoCAD SHX Text Curbing

AutoCAD SHX Text

24" RCP

AutoCAD SHX Text

24" RCP

AutoCAD SHX Text

INV.:681.25'

AutoCAD SHX Text

SDMH RIM:687.85' INV.IN:682.45' INV. OUT:682.02'

AutoCAD SHX Text

INV.:680.60'

AutoCAD SHX Text

RIP RAP

AutoCAD SHX Text

RIP RAP

AutoCAD SHX Text

18" RCP

AutoCAD SHX Text

INV.:685.51'

AutoCAD SHX Text

INV.:686.05'

AutoCAD SHX Text

10" PVC

AutoCAD SHX Text

SDMH RIM:689.29' INV.IN:681.19' (S) INV. IN:681.29' (SW) INV. OUT:681.04'

AutoCAD SHX Text

DROP INLET RIM:687.90' INV. OUT:682.97'

AutoCAD SHX Text

18" RCP

AutoCAD SHX Text

8" RCP

AutoCAD SHX Text

CURB INLET TOP CURB:688.46' INV. OUT:682.80'

AutoCAD SHX Text

EXISTING STEEL BUILDING

AutoCAD SHX Text

EXISTING STEEL BUILDING

AutoCAD SHX Text 40.0'

AutoCAD SHX Text 40.0'

AutoCAD SHX Text 13.4'

AutoCAD SHX Text 13.4'

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SSMH RIM:690.51' INV.IN:684.71' INV. OUT:684.41'

AutoCAD SHX Text

SSMH RIM:684.23' INV.IN:676.88' INV. OUT:676.83'

AutoCAD SHX Text

SSMH RIM:673.03' INV.IN:664.13' INV. OUT:663.93'

AutoCAD SHX Text

POSSIBLE JUNCTION BLOCK, UNFOUND

AutoCAD SHX Text 19.8'

AutoCAD SHX Text 39.8'

AutoCAD SHX Text

MW

AutoCAD SHX Text

ICV

AutoCAD SHX Text

EV

RIPRAP CONDUIT OUTLET PROTECTION

TREELINE AND LIMITS OF CLEARING

OPTION 1: 5' WIDE CONCRETE ABA SIDEWALK

(5% MAX. RUNNING SLOPE) AND CROSSWALK

44'x40.5' STORAGE MAGAZINE (AGM-1)

111' EXPLOSIVE ARC (IBD FOR AGM-1)

100' EXPLOSIVE ARC (IBD &

PTRD FOR EOL-1)

44'-8" X 21'-4" ADMINISTRATION BUILDING

F.F. ELEV.: 683.35'

D

WV

W

T

T

S

W

ICV

D

EV

E

E

E

S

S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S

S

U

T

PARCEL 11510205

CITY OF CHARLOTTE

PARCEL 11510205

CITY OF CHARLOTTE

PARCEL 11521103A

CITY OF CHARLOTTE

PARCEL 11521103A

CITY OF CHARLOTTE

WV

WV

WV

WV

S S

S S

S S

S S

S S

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W W

W W

W

W

W

W

W

W

W

W

W

W

W

E

E

E

E

E

E

E

E

E

E E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

R

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

RESTORE DRIVEWAYS FOR

UNDERGROUND SERVICES (TYP.)

CONCRETE PAD FOR MECHANICAL EQUIPMENT SET 3'

AWAY FROM BUILDING. SEE DETAIL ON MECHANICAL

DRAWINGS FOR FURTHER INFORMATION

2" THICK NCDOT S9.5C HOT MIX ASPHALT SURFACE COURSE.

CONTRACTOR SHALL SWEEP AND APPLY TACK COAT PRIOR

TO SURFACE COURSE INSTALLATION

15' LONG MODULAR BLOCK RETAINING WALL

TOP OF WALL ELEV.: 680'

BOTTOM OF WALL ELEV.: 678'

(11) CONCRETE FILLED STEEL BOLLARDS

FOR VEHICLE PROTECTION @ 5' O.C.

OPTION 1: PAVEMENT WIDENING FOR 9' X

18' STALL PARKING IMPROVEMENTS

OPTION 1: ABA PARKING STALL WITH TRAFFIC

MARKING, SIGNAGE, AND STRIPED ACCESS

AISLE. ABA STALL WITH 2.0% MAX. SLOPES.

OPTION 1: TRAFFIC STRIPING TO

PREVENT PARKING WITHIN OFFSET

RADIUS FROM M&I BUILDING

TW 680'

BW 678'

TW 680'

BW 678'

X

685.55'

S

S

S

S

S S

S S

S

S

S

S

S

S

24'

OPTION 1: CROSSWALK

WITH TRAFFIC MARKING

7' 8"

15' X 20' M&I MAGAZINE (EOL-1)

RESTORE EXISTING FENCES, GATES, AND

ACCESS TELEMETRY/CONTROLS FOR

ANY UTILITY SERVICE WORK

OPTION 1: 9" X 6' PRECAST

CONCRETE WHEEL STOP

(8) CONCRETE FILLED STEEL

BOLLARDS FOR VEHICLE PROTECTION

E U

/C U

E U

C

U

E U

C

U

E

U

C

U

E U

C

U

E U

C

U

E U

C

U

10' X 8' CONCRETE ABA ENTRANCE

SIDEWALK (5% MAX. RUNNING SLOPE)

EMERGENCY SHOWER AND EYE/FACE WASH

UNIT WITH HEAT TRACE. SEE PLUMBING

DRAWINGS FOR FURTHER INFORMATION

R

R

103' STANDOFF (PTRD FOR AGM-1)

40.5

35'

(11) CONCRETE FILLED STEEL

BOLLARDS FOR VEHICLE PROTECTION

2" THICK NCDOT S9.5C HOT MIX ASPHALT SURFACE COURSE, WITH

5" THICK NCDOT I19.0C STABILIZED BASE COURSE WITH 6" THICK

DGA ON TOP OF SELECT BACKFILL. CONTRACTOR SHALL SWEEP

AND APPLY TACK COAT PRIOR TO INSTALLATION. MAINTAIN

POSITIVE DRAINAGE AWAY FROM BUILDING EXTENTS.

4" THICK, AIR ENTRAINED 4,500 PSI CONCRETE, SEE

SIDEWALK DETAIL. MAINTAIN POSITIVE DRAINAGE

AROUND BUILDING EXTENTS. INSTALL BITUMINOUS

EXPANSION JOINTS BETWEEN CONCRETE AND

EXISTING CONCRETE AND BUILDING. SEAL

EXPANSION JOINTS WITH SILICONE SEALANT.

(4) CONCRETE FILLED STEEL

BOLLARDS FOR VEHICLE PROTECTION

REPLACE ASPHALT PAVEMENT

FOR ELECTRICAL AND

COMMUNICATION SERVICE. (TYP.)

10'

5.5'

5.2'

REPLACE ASPHALT PAVEMENT FOR FIRE WATER

SERVICE AND POTABLE WATER SERVICE.

REPLACE ASPHALT PAVEMENT FOR

ELECTRICAL SERVICE

SCALE: 1" = 30'

60300

D

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

April 5, 2021

398570

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

DMR

P r o j e c t

N o

F

J R

P

C h a r l o t t e

A s e

C

D I A

N

C

N o r r o l i n a

A i r

N a t i o n a l

G u a r d

C

B

A

D

C

B

A

54321

1 W oo d A ve S ou th

Ise lin

, N J 0

-4

3.3

.34

| m ott ma c.c om

M

IN

UT

EM

AN

W

AY

CH

AR

LO

TT

E, N

C

C

C o n v e r s i o n

C

M p a n s i o n

SHEET OF 53

06/08/2021MV FEEDER & CONDUIT1

W

T

S

WV

SIGN

WATER METER

WATER VALVE

HYDRANT

SANITARY SEWER MANHOLE

TELEPHONE PEDESTAL

MONITORING WELL

UTILITY POLE

LIGHT POLE

GUY WIRE

DROP INLET

RCP REINFORCED CONCRETE PIPE

OVERHEAD UTILITIES

U

E

W

T

D STORM DRAINAGE MANHOLE

ELECTRIC BOX

EXISTING BOLLARD

MISC. UTILITY BOX

IRRIGATION CONTROL VALVE

BFP BACKFLOW PREVENTER

TBM TEMPORARY BENCHMARK

EMERGENCY SHUT-OFF VALVE

WATER FAUCET

GATE TELEPHONE

HAZARDOUS WASTE SATELLITE

SCALE: 1" = 30'

SITE PLAN

C101

TYPE B-3 SUBMISSION

SITE PLAN

LP/MV

LP/MV

LP

D W

G

N

A M

E

C

U

S E

R S

V

O E

A

P P

D A

T A

L O

C A

L P

R O

J E

C T

W I S

E W

O R

K D

I R

M

O T

T U

S E

P

W D

M S

N

C A

N G

M

S A

B

R

E S

U B

D

V

E

D

A T

E

V

O E

O

T

D

A T

E

SS SANITARY SEWER LINE

W W WATER LINE

STORM SEWER LINE

GAS SERVICE LINE

COMMUNICATION LINE

TEMPORARY SILT FENCE

E ELECTRIC LINE

GAS LINE

NOTE:

1. SEE DRAWING CD101 FOR PHASING SEQUENCE

2. SEE ELECTRICAL DRAWINGS FOR ADDITIONAL

TRENCHING LOCATIONS FOR CONDUITS AND DUCT

BANKS.

VICINITY MAP

(NOT TO SCALE)

I-85

SITE

Exit

10A

I

Exit

U S

H W

Y

/7

W ilk in s o n B lv d

B i l l y

G r a h a m

P k w y

M o r r e s t F li g h t

D r

M i n u t e m a n

W a y

M in u t e m a n

W a y

BOLLARD

AutoCAD SHX Text

CATCH BASIN RIM:656.93'

AutoCAD SHX Text

CATCH BASIN RIM:656.81'

AutoCAD SHX Text

CATCH BASIN RIM:659.95'

AutoCAD SHX Text

CATCH BASIN RIM:659.96'

AutoCAD SHX Text pavement edge

AutoCAD SHX Text pavement edge

AutoCAD SHX Text back of curb

AutoCAD SHX Text back of curb

AutoCAD SHX Text fence line

AutoCAD SHX Text

MINUTEMAN WAY

AutoCAD SHX Text Gate

AutoCAD SHX Text Gate

AutoCAD SHX Text Sectionalizer

AutoCAD SHX Text

MW

AutoCAD SHX Text Transformer

AutoCAD SHX Text Vault

AutoCAD SHX Text

BFP

AutoCAD SHX Text

EXISTING BUILDING

AutoCAD SHX Text

EXISTING BUILDING

AutoCAD SHX Text

FFE:689.71'

AutoCAD SHX Text asphalt

AutoCAD SHX Text asphalt

AutoCAD SHX Text asphalt

AutoCAD SHX Text asphalt

AutoCAD SHX Text asphalt

AutoCAD SHX Text asphalt

AutoCAD SHX Text concrete

AutoCAD SHX Text Concrete Sidewalk

AutoCAD SHX Text Concrete Sidewalk

AutoCAD SHX Text Concrete Sidewalk

AutoCAD SHX Text pavement edge

AutoCAD SHX Text pavement edge

AutoCAD SHX Text pavement edge

AutoCAD SHX Text pavement edge

AutoCAD SHX Text concrete

AutoCAD SHX Text concrete

AutoCAD SHX Text concrete

AutoCAD SHX Text Fence line

AutoCAD SHX Text Fence line

AutoCAD SHX Text Tree line

AutoCAD SHX Text Tree line

AutoCAD SHX Text Tree line

AutoCAD SHX Text Tree line

AutoCAD SHX Text 10" Oak

AutoCAD SHX Text 10" Oak

AutoCAD SHX Text 10" Oak

AutoCAD SHX Text gravel

AutoCAD SHX Text

TBM FLANGE BOLT ON HYDRANT ELEV.:688.83'

AutoCAD SHX Text Curbing

AutoCAD SHX Text Curbing

AutoCAD SHX Text Curbing

AutoCAD SHX Text Curbing

AutoCAD SHX Text

24" RCP

AutoCAD SHX Text

24" RCP

AutoCAD SHX Text

INV.:681.25'

AutoCAD SHX Text

SDMH RIM:687.85' INV.IN:682.45' INV. OUT:682.02'

AutoCAD SHX Text

INV.:680.60'

AutoCAD SHX Text

RIP RAP

AutoCAD SHX Text

RIP RAP

AutoCAD SHX Text

18" RCP

AutoCAD SHX Text

INV.:685.51'

AutoCAD SHX Text

INV.:686.05'

AutoCAD SHX Text

10" PVC

AutoCAD SHX Text

SDMH RIM:689.29' INV.IN:681.19' (S) INV. IN:681.29' (SW) INV. OUT:681.04'

AutoCAD SHX Text

DROP INLET RIM:687.90' INV. OUT:682.97'

AutoCAD SHX Text

18" RCP

AutoCAD SHX Text

8" RCP

AutoCAD SHX Text

CURB INLET TOP CURB:688.46' INV. OUT:682.80'

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SSMH RIM:690.51' INV.IN:684.71' INV. OUT:684.41'

AutoCAD SHX Text

SSMH RIM:684.23' INV.IN:676.88' INV. OUT:676.83'

AutoCAD SHX Text

SSMH RIM:673.03' INV.IN:664.13' INV. OUT:663.93'

AutoCAD SHX Text

POSSIBLE JUNCTION BLOCK, UNFOUND

AutoCAD SHX Text

MW

AutoCAD SHX Text

LEGEND

AutoCAD SHX Text

ICV

OPTION 1: RESTORE AREA WITH

TOPSOIL, FERTILIZER, SEED, AND

STRAW MULCH

RESTORE AREA WITH TOPSOIL,

FERTILIZER, SEED, AND STRAW MULCH

RESTORE AREA WITH TOPSOIL,

FERTILIZER, SEED, AND STRAW MULCH

RESTORE AREA WITH TOPSOIL, FERTILIZER,

SEED, AND STRAW MULCH

D

WV

W

T

T

S

W

ICV

D

EV

E

E

E

S

S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S

S

U

T

PARCEL 11510205

CITY OF CHARLOTTE

PARCEL 11510205

CITY OF CHARLOTTE

PARCEL 11521103A

CITY OF CHARLOTTE

PARCEL 11521103A

CITY OF CHARLOTTE

WV

WV

WV

WV

S S

S S

S S

S S

S S

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W W

W W

W

W

W

W

W

W

W

W

W

W

W

E

E

E

E

E

E

E

E

E

E E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

S

S

S

S

S S

S S

S

S

S

S

S

S

RESTORE AREA WITH TOPSOIL,

FERTILIZER, SEED, AND STRAW MULCH

RIPRAP CONDUIT OUTLET PROTECTION

RESTORE AREA WITH TOPSOIL,

FERTILIZER, SEED, AND STRAW MULCH

RESTORE AREA WITH TOPSOIL, FERTILIZER,

SEED, AND STRAW MULCH

SCALE: 1" = 30'

60300

D

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

April 5, 2021

398570

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

DMR

P r o j e c t

N o

F

J R

P

C h a r l o t t e

A s e

C

D I A

N

C

N o r r o l i n a

A i r

N a t i o n a l

G u a r d

C

B

A

D

C

B

A

54321

1 W oo d A ve S ou th

Ise lin

, N J 0

-4

3.3

.34

| m ott ma c.c om

M

IN

UT

EM

AN

W

AY

CH

AR

LO

TT

E, N

C

C

C o n v e r s i o n

C

M p a n s i o n

SHEET OF 53

06/08/2021MV FEEDER & CONDUIT1

W

T

S

WV

SIGN

WATER METER

WATER VALVE

HYDRANT

SANITARY SEWER MANHOLE

TELEPHONE PEDESTAL

MONITORING WELL

UTILITY POLE

LIGHT POLE

GUY WIRE

DROP INLET

RCP REINFORCED CONCRETE PIPE

U

E

W

T

D STORM DRAINAGE MANHOLE

ELECTRIC BOX

EXISTING BOLLARD

MISC. UTILITY BOX

IRRIGATION CONTROL VALVE

BFP BACKFLOW PREVENTER

TBM TEMPORARY BENCHMARK

EMERGENCY SHUT-OFF VALVE

WATER FAUCET

GATE TELEPHONE

HAZARDOUS WASTE SATELLITE

SCALE: 1" = 30'

LANDSCAPE PLAN

C102

TYPE B-3 SUBMISSION

LANDSCAPE PLAN

LP

LP

LP

D W

G

N

A M

E

C

U

S E

R S

V

O E

A

P P

D A

T A

L O

C A

L P

R O

J E

C T

W I S

E W

O R

K D

I R

M

O T

T U

S E

P

W D

M S

N

C A

N G

M

S A

B

R

E S

U B

D

V

E

D

A T

E

V

O E

O

T

D

A T

E

OVERHEAD UTILITIES

SS SANITARY SEWER LINE

W W WATER LINE

STORM SEWER LINE

GAS SERVICE LINE

COMMUNICATION LINE

TEMPORARY SILT FENCE

E ELECTRIC LINE

GAS LINE

NOTE:

1. SEE DRAWING CD101 FOR PHASING SEQUENCE

2. RESTORE ALL DISTURBED AREAS WITH TOPSOIL, FERTILIZER, SEED AND

STRAW MULCH

VICINITY MAP

(NOT TO SCALE)

I-85

SITE

Exit

10A

I

Exit

U S

H W

Y

/7

W ilk in s o n B lv d

B i l l y

G r a h a m

P k w y

M o r r e s t F li g h t

D r

M i n u t e m a n

W a y

M in u t e m a n

W a y

BOLLARD

AutoCAD SHX Text

CATCH BASIN RIM:656.93'

AutoCAD SHX Text

CATCH BASIN RIM:656.81'

AutoCAD SHX Text

CATCH BASIN RIM:659.95'

AutoCAD SHX Text

CATCH BASIN RIM:659.96'

AutoCAD SHX Text pavement edge

AutoCAD SHX Text pavement edge

AutoCAD SHX Text back of curb

AutoCAD SHX Text back of curb

AutoCAD SHX Text fence line

AutoCAD SHX Text

MINUTEMAN WAY

AutoCAD SHX Text Gate

AutoCAD SHX Text Gate

AutoCAD SHX Text Sectionalizer

AutoCAD SHX Text

MW

AutoCAD SHX Text Transformer

AutoCAD SHX Text Vault

AutoCAD SHX Text

BFP

AutoCAD SHX Text

EXISTING BUILDING

AutoCAD SHX Text

EXISTING BUILDING

AutoCAD SHX Text

FFE:689.71'

AutoCAD SHX Text asphalt

AutoCAD SHX Text asphalt

AutoCAD SHX Text asphalt

AutoCAD SHX Text asphalt

AutoCAD SHX Text asphalt

AutoCAD SHX Text asphalt

AutoCAD SHX Text concrete

AutoCAD SHX Text Concrete Sidewalk

AutoCAD SHX Text Concrete Sidewalk

AutoCAD SHX Text Concrete Sidewalk

AutoCAD SHX Text pavement edge

AutoCAD SHX Text pavement edge

AutoCAD SHX Text pavement edge

AutoCAD SHX Text pavement edge

AutoCAD SHX Text concrete

AutoCAD SHX Text concrete

AutoCAD SHX Text concrete

AutoCAD SHX Text Fence line

AutoCAD SHX Text Fence line

AutoCAD SHX Text Tree line

AutoCAD SHX Text Tree line

AutoCAD SHX Text Tree line

AutoCAD SHX Text Tree line

AutoCAD SHX Text 10" Oak

AutoCAD SHX Text 10" Oak

AutoCAD SHX Text 10" Oak

AutoCAD SHX Text gravel

AutoCAD SHX Text

TBM FLANGE BOLT ON HYDRANT ELEV.:688.83'

AutoCAD SHX Text Curbing

AutoCAD SHX Text Curbing

AutoCAD SHX Text Curbing

AutoCAD SHX Text Curbing

AutoCAD SHX Text

24" RCP

AutoCAD SHX Text

24" RCP

AutoCAD SHX Text

INV.:681.25'

AutoCAD SHX Text

SDMH RIM:687.85' INV.IN:682.45' INV. OUT:682.02'

AutoCAD SHX Text

INV.:680.60'

AutoCAD SHX Text

RIP RAP

AutoCAD SHX Text

RIP RAP

AutoCAD SHX Text

18" RCP

AutoCAD SHX Text

INV.:685.51'

AutoCAD SHX Text

INV.:686.05'

AutoCAD SHX Text

10" PVC

AutoCAD SHX Text

SDMH RIM:689.29' INV.IN:681.19' (S) INV. IN:681.29' (SW) INV. OUT:681.04'

AutoCAD SHX Text

DROP INLET RIM:687.90' INV. OUT:682.97'

AutoCAD SHX Text

18" RCP

AutoCAD SHX Text

8" RCP

AutoCAD SHX Text

CURB INLET TOP CURB:688.46' INV. OUT:682.80'

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SSMH RIM:690.51' INV.IN:684.71' INV. OUT:684.41'

AutoCAD SHX Text

SSMH RIM:684.23' INV.IN:676.88' INV. OUT:676.83'

AutoCAD SHX Text

SSMH RIM:673.03' INV.IN:664.13' INV. OUT:663.93'

AutoCAD SHX Text

POSSIBLE JUNCTION BLOCK, UNFOUND

AutoCAD SHX Text

MW

AutoCAD SHX Text

LEGEND

AutoCAD SHX Text

ICV

0+00 1+00

CATCHBASIN

RIM 682.8'

CATCHBASIN

RIM 682.5'

HEADWALL OUTLET

INV. 677.3'

23 LF - 15"

Reinforced Concrete Pipe

@ 0.44%

I N

V

I N

V

30 LF - 15"

Reinforced Concrete Pipe

@ 1.00%

I N

V

I N

V

EXISTING

GRADE

NOTE:

REINFORCED CONCRETE PIPE SHALL BE ASTM CLASS III PIPE.

4" Ø PVC SDR- 35

SANITARY LATERAL

SLOPE GRADE TO

CATCHBASIN

2" Ø GAS SERVICE

2" Ø WATER SERVICE

6" Ø FIRE WATER SERVICE

COMMUNICATION

DUCT BANK

EU/C

U

E U

C

U

E U

C

U

E

U

C

U

E U

C

U

E U

C

U

E U

C

U

RELOCATE EXISTING 8" Ø C900 PVC WATER MAIN

15"Ø RCP STORM SEWER

CORE AND SEAL MANHOLE FOR LATERAL CONNECTION

AND RECONSTRUCT CHANNEL AND BENCHING

2"Ø WATER SERVICE

ELECTRICAL AND COMMUNICATION SERVICES,

SEE SHEET ES101 FOR CONTINUATION

REMOVE EXISTING UNDERGROUND

COMMUNICATION LINES AS NECESSARY

D

WV

W

T

T

S

W

ICV

D

EV

E

E

E

S

S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S

S

U

T

PARCEL 11510205

CITY OF CHARLOTTE

PARCEL 11510205

CITY OF CHARLOTTE

PARCEL 11521103A

CITY OF CHARLOTTE

PARCEL 11521103A

CITY OF CHARLOTTE

WV

WV

WV

WV

S S

S S

S S

S S

S S

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W W

W W

W

W

W

W

W

W

W

W

W

W

W

E

E

E

E

E

E

E

E

E

E E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E E

E

E

E

E

E

E

E

W

W

W

S

S

S

S

SS

W

W

W

INV.

677.0'

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

4"Ø SDR-35 PVC SANITARY SEWER LATERAL

@ 3.08% SLOPE WITH (2) CLEANOUTS

GRT

682.8'

INV.

677.6'

INV.:

680.70'

6" Ø PVC ROOF DRAIN HEADER PIPE SYSTEM WITH DISCHARGE

TO RIPRAP INCLUDING CLEANOUT ASSEMBLIES AS NECESSARY

AND DOWNSPOUTS WITH CLEANOUTS

2" Ø NATURAL GAS SERVICE

COMMUNICATION LINE SERVICE

S

S

S

S

S S

S S

S

S

S

S

S

S

CONTRACTOR SHALL PERFORM TEST PIT TO VERIFY

MATERIAL AND SIZE OF EXISTING WATER MAIN

ELECTRICAL SERVICE, SEE SHEET ES101

FOR CONTINUATION

PRECAST CONCRETE

FLAT GRATE STORM

SEWER INLETS

GRT 682.5'

INV. 677.5'

3: STONE RIPRAP CONDUIT OUTLET

PROTECTION WITH FILTER FABRIC, 9"

THICK

F.F. ELEV.:

683.35'

X

683.00'

8" Ø C900 PVC 45° FITTING WITH CONCRETE THRUST BLOCK

8" Ø PLUG WITH CONCRETE THRUST BLOCK

2-1/2"Ø FIRE WATER SERVICE FOR SPRINKLER

SYSTEM AND 2"Ø POTABLE WATER SERVICE TO

EMERGENCY EYEWASH AND SHOWER AT M&I

MAGAZINE. WET TAP EXISTING 6"Ø WATERMAIN

FOR FIRE WATER SERVICE AND POTABLE WATER

SERVICE. SEE WET TAP CONNECTION DETAIL.

COMMUNICATION SERVICE, SEE SHEET

ES101 FOR CONTINUATION

W

2" x1-1/4" REDUCER AND NPT CONNECTION

TO EMERGENCY EYEWASH AND SHOWER

CONTRACTOR TO COORDINATE UTILITY LOCATIONS

PRECAST CONCRETE HEADWALL

TOW 680.0'

INV. 677.2'

W

W W

6"Ø FIRE WATER SERVICE FOR SPRINKLER SYSTEM

WITH (3) 90° FITTINGS AND CONCRETE THRUST BLOCKS

CO

CO

ELECTRICAL AND COMMUNICATION SERVICES,

SEE SHEET ES101 FOR CONTINUATION

0+00 1+00 1+72

72 LF - 4"

@ 3.08%

I N

V

I N

V

EXISTING GRADE

48 LF - 4"

@ 3.09%

I N

V

I N

V

PVC SDR-35 PVC SDR-35

EXISTING MANHOLE

CORE AND SEAL MANHOLE FOR NEW

LATERAL CONNECTION AND RECONSTRUCT

CHANNEL AS NECESSARY

PROPOSED BUILDING

SANITARY LATERAL

S S

M H

R I M

CLEANOUT (TYP.)

15" Ø RCP STORM

DRAINAGE LINE

2" Ø WATER SERVICE

6" Ø FIRE WATER SERVICE

EXISTING 8" Ø WATER MAIN

VERIFY LOCATION IN FIELD

EXISTING (2) 3" DUCT BANK

VERIFY LOCATION IN FIELD

EXISTING 8"Ø WATER MAIN

VERIFY LOCATION IN FIELD

EXISTING 4"Ø GAS VERIFY

LOCATION IN FIELD

SCALE: 1" = 30'

60300

NOTE:

CONTRACTOR SHALL RESTORE ALL DISTURBED BURIED UTILITIES AND SURFACES TO

EXISTING CONDITIONS.

SCALE: 1" = 30'

GRADING, DRAINAGE, AND UTILITY PLAN

ADMINISTRATION BUILDING SANITARY LATERAL PROFILE

SCALE: 1" = 20'-0" H, 1" = 5' V

STORM DRAINAGE PROFILE

SCALE: 1" = 20'-0" H, 1" = 5' V

C103

TYPE B-3 SUBMISSION

GRADING, DRAINAGE, AND

UTILITY PLAN

LP

LP

LP

D W

G

N

A M

E

C

U

S E

R S

V

O E

A

P P

D A

T A

L O

C A

L P

R O

J E

C T

W I S

E W

O R

K D

I R

M

O T

T U

S E

P

W D

M S

R

E C

U

P D

A T

E D

U

T I L I T

Y

P

L A

N

W

I T

H

P

R O

F I L E

D

V

E

D

A T

E

V

O E

O

T

D

A T

E

A

M

VICINITY MAP

(NOT TO SCALE)

I-85

SITE

Exit

10A

I

Exit

U S

H W

Y

/7

W ilk in s o n B lv d

B i l l y

G r a h a m

P k w y

M o r r e s t F li g h t

D r

M i n u t e m a n

W a y

M in u t e m a n

W a y

D

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

April 5, 2021

398570

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

DMR

P r o j e c t

N o

F

J R

P

C h a r l o t t e

A s e

C

D I A

N

C

N o r r o l i n a

A i r

N a t i o n a l

G u a r d

C

B

A

D

C

B

A

54321

1 W oo d A ve S ou th

Ise lin

, N J 0

-4

3.3

.34

| m ott ma c.c om

M

IN

UT

EM

AN

W

AY

CH

AR

LO

TT

E, N

C

C

C o n v e r s i o n

C

M p a n s i o n

SHEET OF 53

06/08/2021MV FEEDER & CONDUIT1

W

T

S

WV

SIGN

WATER METER

WATER VALVE

HYDRANT

SANITARY SEWER MANHOLE

TELEPHONE PEDESTAL

MONITORING WELL

UTILITY POLE

LIGHT POLE

GUY WIRE

DROP INLET

RCP REINFORCED CONCRETE PIPE

U

E

W

ICV

T

D STORM DRAINAGE MANHOLE

ELECTRIC BOX

EXISTING BOLLARD

MISC. UTILITY BOX

IRRIGATION CONTROL VALVE

BFP BACKFLOW PREVENTER

TBM TEMPORARY BENCHMARK

EV EMERGENCY SHUT-OFF VALVE

WATER FAUCET

GATE TELEPHONE

HAZARDOUS WASTE SATELLITE

OVERHEAD UTILITIES

SS SANITARY SEWER LINE/CLEAN OUT

W W WATER LINE

STORM SEWER LINE

GAS SERVICE LINE

COMMUNICATION LINE

TEMPORARY SILT FENCE

E ELECTRIC LINE

GAS LINE

THRUST BLOCK

BOLLARD

CO

AutoCAD SHX Text Gate

AutoCAD SHX Text Gate

AutoCAD SHX Text Sectionalizer

AutoCAD SHX Text

MW

AutoCAD SHX Text Transformer

AutoCAD SHX Text Vault

AutoCAD SHX Text

BFP

AutoCAD SHX Text

EXISTING BUILDING

AutoCAD SHX Text

EXISTING BUILDING

AutoCAD SHX Text

FFE:689.71'

AutoCAD SHX Text asphalt

AutoCAD SHX Text asphalt

AutoCAD SHX Text asphalt

AutoCAD SHX Text asphalt

AutoCAD SHX Text asphalt

AutoCAD SHX Text asphalt

AutoCAD SHX Text concrete

AutoCAD SHX Text Concrete Sidewalk

AutoCAD SHX Text Concrete Sidewalk

AutoCAD SHX Text Concrete Sidewalk

AutoCAD SHX Text pavement edge

AutoCAD SHX Text pavement edge

AutoCAD SHX Text pavement edge

AutoCAD SHX Text pavement edge

AutoCAD SHX Text pavement edge

AutoCAD SHX Text pavement edge

AutoCAD SHX Text concrete

AutoCAD SHX Text concrete

AutoCAD SHX Text concrete

AutoCAD SHX Text Fence line

AutoCAD SHX Text Fence line

AutoCAD SHX Text Tree line

AutoCAD SHX Text Tree line

AutoCAD SHX Text Tree line

AutoCAD SHX Text Tree line

AutoCAD SHX Text 10" Oak

AutoCAD SHX Text 10" Oak

AutoCAD SHX Text 10" Oak

AutoCAD SHX Text gravel

AutoCAD SHX Text

TBM FLANGE BOLT ON HYDRANT ELEV.:688.83'

AutoCAD SHX Text Curbing

AutoCAD SHX Text Curbing

AutoCAD SHX Text Curbing

AutoCAD SHX Text Curbing

AutoCAD SHX Text

24" RCP

AutoCAD SHX Text

24" RCP

AutoCAD SHX Text

INV.:681.25'

AutoCAD SHX Text

SDMH RIM:687.85' INV.IN:682.45' INV. OUT:682.02'

AutoCAD SHX Text

INV.:680.60'

AutoCAD SHX Text

RIP RAP

AutoCAD SHX Text

RIP RAP

AutoCAD SHX Text

18" RCP

AutoCAD SHX Text

INV.:685.51'

AutoCAD SHX Text

INV.:686.05'

AutoCAD SHX Text

10" PVC

AutoCAD SHX Text

SDMH RIM:689.29' INV.IN:681.19' (S) INV. IN:681.29' (SW) INV. OUT:681.04'

AutoCAD SHX Text

DROP INLET RIM:687.90' INV. OUT:682.97'

AutoCAD SHX Text

18" RCP

AutoCAD SHX Text

8" RCP

AutoCAD SHX Text

CURB INLET TOP CURB:688.46' INV. OUT:682.80'

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SSMH RIM:690.51' INV.IN:684.71' INV. OUT:684.41'

AutoCAD SHX Text

SSMH RIM:684.23' INV.IN:676.88' INV. OUT:676.83'

AutoCAD SHX Text

SSMH RIM:673.03' INV.IN:664.13' INV. OUT:663.93'

AutoCAD SHX Text

POSSIBLE JUNCTION BLOCK, UNFOUND

AutoCAD SHX Text

MW

LEGEND

ICV

E

E

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

U

T

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

E

E

E

E E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

S

S

S

S

S

S

S

S

S

S

S

S

S S

S S

S S

S S

S S

S

S

S

S

S

S

S

S

S

S

S

S

37.5KVA TRANSFORMER

15KV SECTIONALIZER

"SC-D"

MEDIUM VOLTAGE CABLE FROM

15KV SECTIONALIZER TO 37.5KVA

TRANSFORMER

200A DISCONNECT

SWITCH AND

METER ASSEMBLY

FEEDER CABLE FROM 37.5KVA

TRANSFORMER TO 200A

DISCONNECT SWITCH

CONDUIT AND WIRING FOR SITE

LIGHTING TO REMAIN (TYP.)

PANELBOARD "DP" TO REMAIN

BOLLARD (TYP.)

SITE LIGHTING FIXTURE

TO REMAIN

BUILDING 71 AND 73,

MAGAZINEE STORAGE

UNITS TO BE DEMOLISHED

BUILDING 74 M&I UNIT TO

BE DEMOLISHED

FEEDERS FROM

PANELBOARD "DP"

TO BUILDINGS 71

AND 73 MAGAZINE

STORAGE UNITS

TELEPHONE LINE, SECURITY

WIRES, AND FIRE ALARM

WIRES FOR BUILDINGS 71 AND

73 MAGAZINE STORAGE UNITS

SCALE: 1" = 30'

60300

SCALE: 1" = 30'

DEMOLITION SITE PLAN

ED101

TYPE B-3 SUBMISSION

ELECTRICAL DEMOLITION PLAN

EJC

EJC

IB

6/4/21MV FEEDER REVISION1

D W

G

N

A M

E

C

P

W W

O R

K I N

G H

M M

F

E D

F

U E

L I N

G C

O N

D

M S

N

C A

N G

M

S A

B

R

E

D D

V

E

D

A T

E

C

O N

O

T

D

A T

E

A

M

GENERAL NOTES:

1. REFER TO DRAWING E001 FOR NOTES, ABBREVIATIONS, AND LEGEND.

2. DEMOLITION, REMOVALS, AND UNDERGROUND CONDUITS TO REMAIN

SHALL BE CAPPED AND FILLED. SITE RESTORATION REQUIREMENTS

SHALL BE COORDINATED WITH CIVIL DRAWINGS.

DEMOLITION NOTES:

DISCONNECT AND REMOVE MEDIUM VOLTAGE CABLE FROM 15KV

SECTIONALIZER "SC-D" TO 37.5KVA TRANSFORMER. ABANDON

ASSOCIATED 2" CONDUIT AFTER CABLE REMOVAL.

DISCONNECT AND REMOVE 37.5KVA TRANSFORMER INCLUDING ALL

STRUCTURAL SUPPORTS AND PADS SERVING THE STORAGE AREA

ELECTRICAL LOADS.

DISCONNECT AND REMOVE FEEDER CABLE AND CONDUIT FROM

37.5KVA TRANSFORMER TO 200A DISCONNECT SWITCH AND METER

ASSEMBLY.

DISCONNECT AND REMOVE METER ASSEMBLY AFTER FEEDER CABLE

DISCONNECTION.

DISCONNECT AND REMOVE 200A DISCONNECT SWITCH SERVING

PANELBOARD "DP."

DEMOLISH BOLLARDS SURROUNDING PANELBOARD "DP," 200A

DISCONNECT SWITCH, AND METER ASSEMBLY.

DISCONNECT AND REMOVE EXTERIOR LIGHT FIXTURES FOR

BUILDINGS 71 AND 73 MAGAZINE STORAGE UNITS.

DISCONNECT AND REMOVE FEEDER CABLES AND ASSOCIATED

CONDUIT FOR BUILDING 71, 73, AND 74 FROM PANELBOARD "DP."

DISCONNECT AND REMOVE TELEPHONE LINE, SECURITY WIRES, AND

FIRE ALARM WIRES FOR BUILDINGS 71, 73, AND 74. ABANDON

CONDUIT IN PLACER. REFER TO CIVIL DRAWINGS FOR ADDITIONAL

INFORMATION.

CONTRACTOR SHALL MAINTAIN POWER TO BUILDINGS 71, 73, AND 74

UNTIL COMPLETION OF STAGE 2 LISTED ON SHEET CD101, ALL

MUNITIONS ARE REMOVED FROM THE SITE, AND THE MSA IS

DECOMMISSIONED.

D

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

April 5, 2021

398570

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

DMR

P r o j e c t

N o

F

J R

P

C h a r l o t e s e

C

D I A

N

C

N o r r o l i n a

A i r

N a t i o n a l

G u a r d

C

B

A

D

C

B

A

54321

1 W oo d A ve S ou th

Ise lin

, N J 0

-4

3.3

.34

| m ott ma c.c om

M

IN

UT

EM

AN

W

AY

CH

AR

LO

TT

E, N

C

C

C o n v e r s i o n

C

M p a n s i o n

SHEET OF 53

AutoCAD SHX Text Gate

AutoCAD SHX Text Gate

AutoCAD SHX Text asphalt

AutoCAD SHX Text asphalt

AutoCAD SHX Text pavement edge

AutoCAD SHX Text pavement edge

AutoCAD SHX Text pavement edge

AutoCAD SHX Text pavement edge

AutoCAD SHX Text Fence line

AutoCAD SHX Text

EXISTING STEEL BUILDING

AutoCAD SHX Text

EXISTING STEEL BUILDING

AutoCAD SHX Text 40.0'

AutoCAD SHX Text 40.0'

AutoCAD SHX Text 13.4'

AutoCAD SHX Text 13.4'

AutoCAD SHX Text 19.8'

39.8'

T

T

S

D

S

S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S

S

U

T

S S

S S

S S

S S

S S

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W W

W W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

S

S

S

S

SS

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

S

S

S

S

S S

S S

S

S

S

S

S

S

W

W

W W

EU

/C

U

E U

C

U

E U

C

U

E

U

C

U

E U

C

U

ADMIN BUILDING

EXISTING 15KV

SECTIONALIZER

REFER TO DRAWING E101 FOR

ADMIN BUILDING ELECTRICAL PLANS

SEE ENLARGED PLAN ON THIS

DRAWING FOR POWER AND

COMMUNICATIONS DISTRIBUTIONS

FOR BUILDINGS

2-4"

EXISTING 2" CONDUIT

EXISTING COMMUNICATIONS

MANHOLE

HHC-4

R-011 R-012

2-4"

R-013 R-014

EXISTING COMMUNICATIONS

DUCTBANK TO BUILDING 72

(APPROX. 1100')

E U

C

U

E U

C

U

HHE-3

HHC-3

2-4"

R-056 R-057

ICV

U

T

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S S

S S

S S

S S

S S

S S

S

S

S

S

S

S

S S

S S

W

W

W

W W

W

W

W

R-001

R-002

R-004

R-005

EU

/C

U

EU

/C

U

EU

/C

U

E U

C

U

STORAGE BUILDING

225KVA UTILITY

TRANSFORMER

EXISTING

PANELBOARD "DP"

HHE-2

M&I BUILDING

BOLLARDS

(TYP)

MAIN DISTRIBUTION

PANELBOARD "MDP"

REFER TO SITE PLAN FOR

CONDUIT CONTINUATION

HHC-2

R-016

HHC-1

R-029

R-038

R-039

R-033

HHE-1

R-017

6-4"

R-007

R-008

R-009

R-010 R-034

12-4"

R-041

R-042

R-003 R-006 R-040 R-043

HHC-5

HHE-4

R-044

R-045

R-047

R-048

R-050

R-051

12-4"

R-053

R-054

R-046 R-049 R-052 R-055

REFER TO DRAWING E102

FOR M&I BUILDING

ELECTRICAL PLANS

E U

C

U

E U

C

U

E U

C

U

E U

C

U

E U

C

U E

U C

U E

U C

U E

U C

U E

U C

U

REFER TO DRAWING E102

FOR STORAGE BUILDING

ELECTRICAL PLANS

SCALE: 1" = 30'

60300

SCALE: 1" = 30'

SITE PLAN

ES101

TYPE B-3 SUBMISSION

ELECTRICAL SITE PLAN

EJC

EJC

IB

6/4/21MV FEEDER REVISION1

D W

G

N

A M

E

C

P

W W

O R

K I N

G H

M M

F

E D

F

U E

L I N

G C

O N

D

M S

N

C A

N G

M

S A

B

R

E

S D

V

E

D

A T

E

C

O N

O

T

D

A T

E

A

M

SCALE: 1" = 10'

ENLARGED ELECTRICAL SITE PLAN

SCALE: 1" = 10'

20100

GENERAL NOTES:

1. REFER TO DRAWING E001 FOR NOTES, ABBREVIATIONS, AND LEGEND.

DEMOLITION NOTES:

FURNISH AND INSTALL 225KVA UTILITY TRANSFORMER INCLUDING SUPPORTS AND PAD IN LOCATION MADE AVAILABLE DURING EXISTING

TRANSFORMER DEMOLITION.

FURNISH AND INSTALL METER ASSEMBLY AND 600A, 3ɸ, 4W MAIN DISTRIBUTION PANELBOARD "MDP." METER ASSEMBLY SHALL BE CONNECTED TO

BUILDING MANAGEMENT SYSTEM FOR MONITORING PURPOSES.

FURNISH AND INSTALL 15KV FEEDER CABLE FROM EXISTING 15KV SECTIONALIZER "SC-D" TO 225KVA UTILITY TRANSFORMER. UTILIZE PROPOSED

DUCTBANK FROM EXISTING 15KV SECTIONALIZER TO TRANSFORMER.

RECONNECT EXISTING PANELBOARD "DP" TO MAIN DISTRIBUTION PANELBOARD "MDP."

REFER TO CIVIL DRAWINGS FOR BOLLARD INSTALLATION AROUND UTILITY TRANSFORMER, MAIN DISTRIBUTION PANELBOARD, AND EXISTING

PANELBOARD "DP."

NOT USED.

NOT USED.

FURNISH AND INSTALL 12 STRAND SINGLE MODE FIBER OPTIC CABLE AND 50 PAIR PE89 COPPER FROM THE ADMIN BUILDING MECH/ELEC/COMM

ROOM TO BUILDING #72 UTILIZING EXISTING/PROPOSED COMMUNICATIONS DUCTBANKS, HANDHOLES, AND EXISTING COMMUNICATIONS MANHOLE

FOR AUTOMATIC ACCESS CONTROL SYSTEM AND TELECOM BOARD, RESPECTIVELY.

D

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

April 5, 2021

398570

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

DMR

P r o j e c t

N o

F

J R

P

C h a r l o t s e

C

D I A

N

C

N o r r o l i n a

A i r

N a t i o n a l

G u a r d

C

B

A

D

C

B

A

54321

1 W oo d A ve S ou th

Ise lin

, N J 0

-4

3.3

.34

| m ott ma c.c om

M

IN

UT

EM

AN

W

AY

CH

AR

LO

TT

E, N

C

C

C o n v e r s i o n

C

M p a n s i o n

SHEET OF 53

AutoCAD SHX Text Gate

AutoCAD SHX Text Gate

AutoCAD SHX Text Fence line

AutoCAD SHX Text Fence line

AutoCAD SHX Text Tree line

AutoCAD SHX Text Tree line

AutoCAD SHX Text Tree line

AutoCAD SHX Text Tree line

AutoCAD SHX Text 10" Oak

AutoCAD SHX Text 10" Oak

AutoCAD SHX Text 10" Oak

AutoCAD SHX Text gravel

AutoCAD SHX Text Curbing

AutoCAD SHX Text Curbing

AutoCAD SHX Text Curbing

AutoCAD SHX Text Curbing

AutoCAD SHX Text

RIP RAP

AutoCAD SHX Text

RIP RAP

AutoCAD SHX Text Gate

AutoCAD SHX Text asphalt

AutoCAD SHX Text pavement edge

AutoCAD SHX Text pavement edge

Fence line

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

April 5, 2021

398570

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

DMR

P r o j e c t

N o

F

J R

P

C h a r l o t s e

C

D I A

N

C

N o r r o l i n a

A i r

N a t i o n a l

G u a r d

C

B

A

D

C

B

A

54321

1 W oo d A ve S ou th

Ise lin

, N J 0

-4

3.3

.34

| m ott ma c.c om

M

IN

UT

EM

AN

W

AY

CH

AR

LO

TT

E, N

C

C

C o n v e r s i o n

C

M p a n s i o n

SHEET OF 53

E602

TYPE B-3 SUBMISSION

CABLE AND CONDUIT

SCHEDULES

EJC

EJC

IB

6/4/21MV FEEDER REVISION1

D W

G

N

A M

E

C

P

W W

O R

K I N

G H

M M

F

E D

F

U E

L I N

G C

O N

D

M S

N

C A

N G

M

S A

B

R

E

D

V

E

D

A T

E

C

O N

O

T

D

A T

E

A

M

CONDUIT SCHEDULE

CONDUIT NUMBER FROM TO SIZE TYPE DESCRIPTION

R-001

MAIN DISTRIBUTION PANELBOARD "MDP" HANDHOLE "HHE-2"

4" PVC

ROUTED THROUGH HHE-1

R-002

MAIN DISTRIBUTION PANELBOARD "MDP" HANDHOLE "HHE-2"

4" PVC

ROUTED THROUGH HHE-1

R-003

MAIN DISTRIBUTION PANELBOARD "MDP" HANDHOLE "HHE-2"

4" PVC

ROUTED THROUGH HHE-1

R-004

MAIN DISTRIBUTION PANELBOARD "MDP" HANDHOLE "HHE-2"

4" PVC

ROUTED THROUGH HHE-1

R-005

HANDHOLE "HHC-1" HANDHOLE "HHC-2"

4" PVC

R-006

HANDHOLE "HHC-1" HANDHOLE "HHC-2"

4" PVC SPARE

R-007

HANDHOLE "HHE-2" HANDHOLE "HHE-3"

4" PVC

R-008

HANDHOLE "HHC-2" HANDHOLE "HHC-3"

4" PVC

R-009

HANDHOLE "HHE-2" HANDHOLE "HHE-3"

4" PVC SPARE

R-010

HANDHOLE "HHC-2" HANDHOLE "HHC-3"

4" PVC

R-011

HANDHOLE "HHC-3" HANDHOLE "HHC-4"

4" PVC

R-012

HANDHOLE "HHC-3" HANDHOLE "HHC-4"

4" PVC SPARE

R-013

HANDHOLE "HHC-4" EXISTING COMMUNICATIONS MANHOLE

2" RGS

R-014

HANDHOLE "HHC-4" EXISTING COMMUNICATIONS MANHOLE

2" RGS SPARE

R-015

HANDHOLE "HHE-4" PANELBOARD "PP-ST"

2" RGS DIRECT BURIAL CONDUIT

R-016

MAIN DISTRIBUTION PANELBOARD "MDP" EXISTING PANELBOARD "DP"

2" RGS DIRECT BURIAL CONDUIT

R-017

EXISTING DISTRIBUTION PANELBOARD "DP" HANDHOLE "HHE-1"

2" RGS DIRECT BURIAL CONDUIT

R-018

HANDHOLE "HHE-3" 200A DOUBLE THROW MANUAL TRANSFER SWITCH

4" RGS

R-019

200A DOUBLE THROW MANUAL TRANSFER SWITCH PANELBOARD "PP-A"

4" RGS

R-020

HANDHOLE "HHC-3" AUTOMATIC ACCESS CONTROL PANEL

2" RGS DIRECT BURIAL CONDUIT

R-021

HANDHOLE "HHC-3" WALL MOUNTED TELECOM BOARD

2" RGS DIRECT BURIAL CONDUIT

R-022

GENERATOR RECEPTACLE 200A DOUBLE THROW MANUAL TRANSFER SWITCH

4" RGS BUILDING PENETRATION BETWEEN RECEPTACLE AND MTS

R-023

HANDHOLE "HHE-2" M&I MAGAZINE BUILDING JUNCTION BOX "JB-1"

2" RGS DIRECT BURIAL CONDUIT

R-024

HANDHOLE "HHE-2" M&I MAGAZINE BUILDING JUNCTION BOX "JB-2"

2" RGS DIRECT BURIAL CONDUIT

R-025

M&I MAGAZINE BUILDING JUNCTION BOX "JB-1" M&I EYEWASH WATER HEATER DISCONNECT SWITCH

2" RGS WALL MOUNTED CONDUIT

R-026

M&I MAGAZINE BUILDING JUNCTION BOX "JB-1" M&I EYEWASH WATER HEATER SIGNALING DEVICE

2" RGS WALL MOUNTED CONDUIT

R-027

M&I MAGAZINE BUILDING JUNCTION BOX "JB-2" 120/240V M&I MAGAZINE BUILDING PANELBOARD

2" RGS WALL MOUNTED CONDUIT

R-028

M&I MAGAZINE BUILDING JUNCTION BOX "JB-2" M&I MAGAZINE BUILDING EYEWASH HEAT TRACE CABLES

2" RGS WALL MOUNTED CONDUIT

R-029

HANDHOLE "HHC-1" METER ASSEMBLY

2" RGS EMPTY CONDUIT DESIGNATED FOR METER CONNECTION TO BMS

R-030

HANDHOLE "HHC-5" STORAGE BUILDING "COMMUNICATIONS JUNCTION BOX"

2" RGS

EMPTY CONDUIT DESIGNATED FOR SITE COMMUNICATIONS, DIRECT BURIAL

R-031

HANDHOLE "HHC-2" M&I MAGAZINE BULDING "COMMUNICATIONS JUNCTION BOX"

2" RGS

R-032

UTILITY TRANSFORMER "T-1" MAIN DISTRIBUTION PANELBOARD "MDP"

4" RGS DIRECT BURIAL CONDUIT

R-033

HANDHOLE "HHE-2" HANDHOLE "HHE-3"

4" PVC SPARE

R-034

HANDHOLE "HHC-2" HANDHOLE "HHC-3"

4" PVC EMPTY CONDUIT DESIGNATED FOR SITE COMMUNICATIONS

R-035

HANDHOLE "HHC-2" M&I MAGAZINE BULDING "SECURITY JUNCTION BOX"

2" RGS EMPTY CONDUIT DESIGNATED FOR SECURITY

R-036

MONOCO "FAMN-1" HANDHOLE "HHC-3"

2" RGS DIRECT BURIAL CONDUIT

R-037

HANDHOLE "HHC-2" M&I MAGAZINE UNIT "FIRE ALARM JUNCTION BOX"

2" RGS

DIRECT BURIAL CONDUIT, FIRE ALARM

R-038

HANDHOLE "HHC-1" HANDHOLE "HHC-2"

4" PVC

R-039

HANDHOLE "HHC-1" HANDHOLE "HHC-2"

4" PVC EMPTY CONDUIT DESIGNATED FOR SITE COMMUNICATIONS

R-040

HANDHOLE "HHC-1" HANDHOLE "HHC-2"

4" PVC

R-041

HANDHOLE "HHC-1" HANDHOLE "HHC-2"

4" PVC SPARE

R-042

HANDHOLE "HHC-1" HANDHOLE "HHC-2"

4" PVC SPARE

R-043

HANDHOLE "HHC-1" HANDHOLE "HHC-2"

4" PVC SPARE

R-044

HANDHOLE "HHE-1" HANDHOLE "HHE-4"

4" PVC

ROUTED THROUGH HHE-1

R-045

HANDHOLE "HHE-1" HANDHOLE "HHE-4"

4" PVC

ROUTED THROUGH HHE-1

R-046

HANDHOLE "HHE-1" HANDHOLE "HHE-4"

4" PVC

ROUTED THROUGH HHE-1

R-047

HANDHOLE "HHE-1" HANDHOLE "HHE-4"

4" PVC SPARE

R-048

HANDHOLE "HHE-1" HANDHOLE "HHE-4"

4" PVC SPARE

R-049

HANDHOLE "HHE-1" HANDHOLE "HHE-4"

4" PVC SPARE

R-050

HANDHOLE "HHC-1" HANDHOLE "HHC-5"

4" PVC

R-051

HANDHOLE "HHC-1" HANDHOLE "HHC-5"

4" PVC EMPTY CONDUIT DESIGNATED FOR SITE COMMUNICATIONS

R-052

HANDHOLE "HHC-1" HANDHOLE "HHC-5"

4" PVC

R-053

HANDHOLE "HHC-1" HANDHOLE "HHC-5"

4" PVC SPARE

R-054

HANDHOLE "HHC-1" HANDHOLE "HHC-5"

4" PVC SPARE

R-055

HANDHOLE "HHC-1" HANDHOLE "HHC-5"

4" PVC SPARE

R-056

EXISTING 15KV SECTIONALIZER

UTILITY TRANSFORMER "T-1" 4" PVC MEDIUM VOLTAGE FEEDER

R-057

EXISTING 15KV SECTIONALIZER

UTILITY TRANSFORMER "T-1" 4" PVC SPARE

R-058 NOT USED

R-059 NOT USED

R-060 NOT USED

R-061 NOT USED

R-062 NOT USED

R-063 NOT USED

R-064

HANDHOLE "HHC-5" STORAGE BUILDING "SECURITY JUNCTION BOX"

2" RGS

R-065

HANDHOLE "HHC-5" STORAGE BUILDING UNIT "FIRE ALARM JUNCTION BOX"

2" RGS DIRECT BURIAL CONDUIT

CABLE SCHEDULE

CABLE TAG CABLE DESCRIPTION FROM TO CONDUIT ROUTING NOTES

P-001

15KV 3#2, 1#6G

EXISTING 15KV SECTIONALIZER UTILITY TRANSFORMER "T-1" R-056 - - - TO BE RUN IN DUCTBANK

P-002

(2) SETS 4#350KCMIL, 1#1/0G

UTILITY TRANSFORMER "T-1" MAIN DISTRIBUTION PANELBOARD "MDP" R-032 - - -

P-003

4#300KCMIL, 1#1G

MAIN DISTRIBUTION PANELBOARD "MDP" 200A DOUBLE THROW MANUAL TRANSFER SWITCH R-001 R-007 R-018 -

P-004

4#300KCMIL, 1#1G

200A DOUBLE THROW MANUAL TRANSFER SWITCH PANELBOARD "PP-A" R-019 - - -

P-005 3#1, 1#6G

MAIN DISTRIBUTION PANELBOARD "MDP" PANELBOARD "PP-M&I" R-002 R-024 R-027 -

P-006 3#1, 1#6G

MAIN DISTRIBUTION PANELBOARD "MDP" PANELBOARD "PP-ST" R-044 R-015 - -

P-007 3#4/0, 1#4G

MAIN DISTRIBUTION PANELBOARD "MDP" EXISTING PANELBOARD "DP" R-016 - - -

P-008 4#4/0, 1#4G

GENERATOR RECEPTACLE 200A DOUBLE THROW MANUAL TRANSFER SWITCH R-022 - - -

P-009 3#1, 1#6G

MAIN DISTRIBUTION PANELBOARD "MDP" M&I BUILDING EYEWASH WATER HEATER R-003 R-023 R-025 -

P-010 2#12, 1#12G

EXISTING DISTRIBUTION PANELBOARD "DP" M&I BUILDING UNIT EYEWASH HEAT TRACE R-017 R-004 R-024 R-028

P-011 2#12, 1#12G

EXISTING DISTRIBUTION PANELBOARD "DP" M&I BUILDING UNIT EYEWASH SIGNALING DEVICE R-017 R-004 R-023 R-026

P-012 12/C FIBER OPTIC CABLE M&I BUILDING AUTOMATIC ACCESS CONTROL PANEL STORAGE BUILDING AUTOMATIC ACCESS CONTROL PANEL R-031 R-040 R-052 R-064

P-013 12/C FIBER OPTIC CABLE ADMIN BUILDING AUTOMATIC ACCESS CONTROL PANEL M&I BUILDING AUTOMATIC ACCESS CONTROL PANEL R-020 R-010 R-031 -

C-001 12/C FIBER OPTIC CABLE BUILDING #72 ADMIN BUILDING AUTOMATIC ACCESS CONTROL PANEL R-013 R-011 R-020 -

C-002 50 PAIR PE89 COPPER WIRE BUILDING #72 ADMINISTRATION BUILDING TELECOM BOARD R-013 R-011 R-021 -

F-001 #14 FIRE ALARM WIRE MONOCO "FAMN-1" M&I AND STORAGE BUILDINGS

R-036 R-008 R-037 R-038

FIRE DETECTION CIRCUIT, ROUTED TO PROPOSED BUILDINGS

R-050 R-065 - -

F-002 #14 FIRE ALARM WIRE MONOCO "FAMN-1" M&I AND STORAGE BUILDINGS

R-036 R-008 R-037 R-038

FIRE NOTIFICATION CIRCUIT, ROUTED TO PROPOSED BUILDINGS

R-050 R-065 - -

MSA Expansion_Revision 1_Civil
01_CD101 - DEMOLTION SITE PLAN
Sheets and Views
CD101 - DEMOLTION SITE PLAN
03_C101 - SITE PLAN
Sheets and Views
C101 - SITE PLAN
04_C102 - LANDSCAPE PLAN
Sheets and Views
C102 - LANDSCAPE PLAN
05_C103 - Utility Plan
Sheets and Views
C103
2021-06-04_NCANG-MSA-Expansion_MV Feeder Revision
Sheets and Views
398570_NCANG-MSA_B3R_ED101-ELECTRICAL DEMOLITION PLAN
398570_NCANG-MSA_B3R_ES101-ELECTRICAL SITE PLAN
398570_NCANG-MSA_B3R_E602-CABLE AND CONDUIT SCHEDULES