MDVL042061 Addendum No. 2 Drawing Mark-ups (rev sht 01FA-104).pdf

PDF 2 MB Posted

Attached to
MDVL042061 - Repair Fire Suppression Systems Bldgs 150, 151, and 160 at the 186th ARW
Solicitation number
W50S7J23B0001
Issued by

About this file

This solicitation is for construction services to repair fire suppression systems in three buildings at Mississippi Air National Guard 186th Air Refueling Wing in Meridian, Mississippi. Services include work in accordance with provided construction plans, statement of work, technical specifications, and statement of work addendum. The work is a 100% total small business set-aside for qualified offerors with a NAICS code of 236220 and size standard of $45 million average annual revenue. The project magnitude ranges from $1 million to $5 million. The pre-bid conference is scheduled for May 16, 2023 with bid opening on June 1, 2023. Interested offerors must register in the System for Award Management to access the solicitation and associated documents available only through the SAM website.

View the file

Other files

Show all 22

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

REMOVE FIRE ALARM DEVICE.

10 10

NEW FIRE ALARM AND MASS

NOTIFICATION SYSTEM

THE MASS NOTIFICATION LOCAL OPERATORS CONCOLE SHALL BE

PROVIDED AS NEW CONNECTED AND CONTROLLED BY THE FIRE

ALARM SYSTEM MONACO MAAP-X.

KEYNOTE #3 IS NO LONGER

APPLICABLE, SEE

CONTRACT ADDENDUM #1

NEW

KEYNOTE #9 IS NO LONGER

APPLICABLE, SEE

CONTRACT ADDENDUM #1

FA/ATI MNS INTERFACE JUNCTION BOX TO BE SHOWN AS BOLD

AND INSTALLED AS PART OF THIS PROJECT. SEE DETAIL #4 ON

SHEE 00FA-501 AS PART OF THIS ADDENDUM.

M

M

M

M

M

M

M

M

M

M

M

M

M

REPLACE THE SPEAKER-ONLY DEVICE WITH A COMBINATION

SPEAKER/STROBE DEVICE SHOWN. KEYNOTE #1 IS NOT

APPLICABLE TO THIS DEVICE.

M

M M

M

M

M

M

M

M

M

10 M

M

M

M

M

M

ATI MASS NOTIFICATION SYSTEM HEAD END

EQUIPMENT HAS NOT BEEN INSTALLED. THIS IS THE

PROPOSED LOCATION FOR THE FUTURE ATI HEAD

END EQUIPMENT. DO NOT PLACE ANY FIRE ALARM

PANELS IN THIS LOCATION.

M

M

M

NEW UNLESS OTHERWISE

NOTED ON THE DRAWINGS.

M

PREVIOUSLY SHOWN ATI MASS NOTIFICATION

COMBINATION A/V DEVICE

IS NOW A NEW COMBINATION DEVICE CONNECTED

AND POWERED BY THE FIRE ALARM SYSTEM.

THE NEW FIRE ALARM DEVICE SHALL BE A

COMBINATION A/V WITH A CLEAR STROBE,

MARKED WITH THE WORD 'ALERT'.

M

M

M

S

PREVIOUSLY SHOWN ATI MASS NOTIFICATION

AUDIBLE DEVICE

IS NOW A NEW AUDIBLE DEVICE CONNECTED AND

POWERED BY THE FIRE ALARM SYSTEM.

THE NEW FIRE ALARM DEVICE SHALL BE A

WEATHERPROOF SPEAKER MARKED WITH THE

WORD 'ALERT'.

S

S

FACU /

RSFACU

LOC

FAA

SPEAKER/

STROBE

WALL-MOUNTED

SPEAKER

NAC/AUX

POWER SUPPLY

FIELD OF VIEW LIMITERCOLLAR ATTACHMENT

MOUNTING ARM INSTALLATION DETAIL

11.75"

10° MIN

1.25" 4.75"

1.5"

4"

4"

3"

Ø0.42"

RIGID MOUNTING SURFACE VIBRATION FREE

3/8" MOUNTING

HARDWARE BY INSTALLING

CONTRACTOR

4 3/4" NPT CONDUIT

ENTRIES.

PLUGS REQUIRED FOR THE

UNUSED ENTRIES

COLLAR

ATTACHMENT

FOV LIMITER

1 INCH RED BLOCK

LETTERING

SIGN TO HAVE WHITE

BACKGROUND COLOR

WITH MINIMUM 1/2 INCH

WIDE BLUE BORDER

OPTICAL

FLAME

DETECTION

DISABLED

WHEN

ILLUMINATED

* PROVIDE ENGRAVED LABELS ON THE DISCONNECT SWITCH INDICATING

WHEN THE SYSTEM IS "ENABLED" OR "DISABLED" DO NOT ROUTE CONDUIT

IN FRONT OF SIGN IN A MANNER THAT OBSTRUCTS ANY LETTERING.

S O

L I C

I T

A T

I O

N

N

O

F I L E

N

A M

E

D W

N

B

Y

C K

D

B

Y

D E

S I G

N E

D

B

Y

D E

S C

R I P

T I O

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

F I L

U M

B E

R

S I Z

E

S U

B M

I T

T E

D

B

Y

P L O

T

S

C A

L E

P

L O

T

D

A T

E

D A

T E

M A

R K

D E

S C

R I P

T I O

N D

A T

E

A N

S I

D

T

H

A

I R

F

U E

L I N

G

W

I N

G

A

R W

D E

S I G

N

R

E P

A

F

R

E

S

U P

P R

E S

S I O

S

T

E D

H D

R

E n g i n e e r i n g

I n c o u t h h r e e t

O M

A H

A

N

E

M I S

S I S

S I P

P I

A

T

I O

N A

L

G

U A

R D

A P

P R

B

S

U B

M I T

T A

L J U

B

S

U B

M I T

T A

L

B U

I L

D I N

G

M E

R I D

I A

N

M

I S

S I S

S I P

P I

P R

O J E

C T

S E

E

C

O V

H E

E T

00FA-501

MOUNTING DETAIL- DET-TRONICS X3301 FLAME DETECTOR

SCALE: NTS

00FA-501

FIRE ALARM AND MNS DEVICE ELEVATION

SCALE: NTS

00FA-501

OPTICAL FLAME DETECTION BYPASS

INDICATOR LIGHT SIGNAGE DETAIL

SCALE: NTS

F

A d w g

Z S

J W

T F

T S

00FA-501

F I R

E

A

L A

M

D

T

A I L

S

J

J

DETAIL #4

00FA-501

THE ATI WIDE AREA MASS

NOTIFICATION SYSTEM

DEMARCATION.

TO FUTURE ATI WIDE

AREA MASS

NOTIFICATION SYSTEM

FACU / WAMNS SYSTEM INTERFACE

INSTALL PRE-PROGRAMMED

ADDRESSABLE CONTROL

RELAY, PRE-PROGRAMMED

ADDRESSABLE MONITOR

MODULE AND 6 ADDITIONAL

CABLES COILED UP IN A 30

FOOT LOOP.

File details come from the government source that posted it. Updated .