This is a solicitation for an indefinite delivery/indefinite quantity (IDIQ) construction contract to provide paving and related services at Joint Base Lewis-McChord in Washington. Work includes removal, replacement, and repair of subgrade, utilities, shoulders, curbs, gutters, sidewalks, and other real property elements associated with roadway and airfield pavements. It may also include minor new construction of roads, sidewalks, or parking lots. Services will be provided through the issuance of fixed-price task orders. The contractor must provide all necessary materials, labor, equipment, tools, transportation, and ancillary items to complete each project. The parent IDC contract is valued at $50 million over a five-year period of performance. Responses are due by February 21, 2020, and the agency is the Department of the Army Materiel Command Mission and Installation Contracting Command at Joint Base Lewis-McChord.
View the file
Other files for this federal contract opportunity
Show all 22
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SECTI ON 26 56 00
EXTERI OR LI GHTI NG
05/13
PART 1 GENERAL
1. 1 REFERENCES
The publ i cat i ons l i s t ed bel ow f or m a par t of t hi s speci f i cat i on t o t he ext ent r ef er enced. The publ i cat i ons ar e r ef er r ed t o i n t he t ext by t he basi c desi gnat i on onl y.
AMERI CAN ASSOCI ATI ON OF STATE HI GHWAY AND TRANSPORTATI ON OFFI CI ALS
(AASHTO)
AASHTO LTS ( 2013; Er r at a 2013) St andar d Speci f i cat i ons f or St r uct ur al Suppor t s f or Hi ghway Si gns, Lumi nai r es and Tr af f i c Signals
AMERI CAN SOCI ETY OF HEATI NG, REFRI GERATI NG AND AI R- CONDI TI ONI NG
ENGI NEERS ( ASHRAE)
ASHRAE 90. 1 - I P ( 2013) Ener gy St andar d f or Bui l di ngs Except Low- Ri se Resi dent i al Bui l di ngs
ASTM I NTERNATI ONAL ( ASTM)
ASTM A123/ A123M ( 2017) St andar d Speci f i cat i on f or Zi nc ( Hot - Di p Gal vani zed) Coat i ngs on I r on and St eel Pr oduct s
ASTM A153/ A153M ( 2016) St andar d Speci f i cat i on f or Zi nc Coat i ng ( Hot - Di p) on I r on and St eel Hardware
ASTM B117 ( 2016) St andar d Pr act i ce f or Oper at i ng Sal t Spr ay ( Fog) Appar at us
I LLUMI NATI NG ENGI NEERI NG SOCI ETY ( I ES)
I ES HB- 10 ( 2011; Er r at a 2015) I ES Li ght i ng Handbook
I ES LM- 79 ( 2008) El ect r i cal and Phot omet r i c Measur ement s of Sol i d- St at e Li ght i ng Products
I ES LM- 80 ( 2015) Measur i ng Lumen Mai nt enance of LED Li ght Sour ces
I ES RP- 8 ( 2018) Recommended Pr act i ce f or Li ght i ng Roadway and Par k i ng Faci l i t i es
I ES RP- 16 ( 2017) Nomencl at ur e and Def i ni t i ons f or I l l umi nat i ng Engi neer i ng
I ES TM- 15 ( 2011) Lumi nai r e Cl assi f i cat i on Syst em f or
SECTI ON 26 56 00 Page 1
Out door Lumi nai r es
I ES TM- 21 ( 2011; Addendum B 2015) Pr oj ect i ng Long Ter m Lumen Mai nt enance of LED Li ght Sour ces
I NSTI TUTE OF ELECTRI CAL AND ELECTRONI CS ENGI NEERS ( I EEE)
I EEE 100 ( 2000; Ar chi ved) The Aut hor i t at i ve Di ct i onar y of I EEE St andar ds Ter ms
I EEE C2 ( 2017; Er r at a 1- 2 2017; I NT 1 2017) Nat i onal El ect r i cal Saf et y Code
I EEE C62. 41. 2 ( 2002) Recommended Pr act i ce on Char act er i zat i on of Sur ges i n Low- Vol t age ( 1000 V and Less) AC Power Ci r cui t s
NATI ONAL ELECTRI CAL MANUFACTURERS ASSOCI ATI ON ( NEMA)
ANSI C136. 3 ( 2014) Amer i can Nat i onal St andar d f or Roadway and Ar ea Li ght i ng Equi pment Lumi nai r e At t achment s
ANSI C136. 13 ( 2014) Roadway and Ar ea Li ght i ng Equi pment
- Met al Br acket s f or Wood Pol es
ANSI C136. 21 ( 2014) Amer i can Nat i onal St andar d f or Roadway and Ar ea Li ght i ng Equi pment - Ver t i cal Tenons Used wi t h Post - Top- Mount ed Luminaires
NEMA 250 ( 2018) Encl osur es f or El ect r i cal Equi pment ( 1000 Vol t s Maxi mum)
NEMA ANSLG C78. 377 ( 2017) El ect r i c Lamps— Speci f i cat i ons f or t he Chr omat i c i t y of Sol i d St at e Li ght i ng Products
NEMA C82. 77 ( 2002) Har moni c Emi ssi on Li mi t s - Rel at ed Power Qual i t y Requi r ement s f or Li ght i ng Equipment
NEMA C136. 31 ( 2018) Roadway and Ar ea Li ght i ng Equi pment
- Lumi nai r e Vi br at i on
NEMA I CS 2 ( 2000; R 2005; Er r at a 2008) I ndust r i al Cont r ol and Syst ems Cont r ol l er s, Cont act or s, and Over l oad Rel ays Rat ed 600 V
NEMA I CS 6 ( 1993; R 2016) I ndust r i al Cont r ol and Syst ems: Encl osur es
NEMA I EC 60529 ( 2004) Degr ees of Pr ot ect i on Pr ovi ded by Encl osur es ( I P Code)
NEMA WD 7 ( 2011; R 2016) Occupancy Mot i on Sensor s Standard
SECTI ON 26 56 00 Page 2
NATI ONAL FI RE PROTECTI ON ASSOCI ATI ON ( NFPA)
NFPA 70 ( 2017; ERTA 1- 2 2017; TI A 17- 1; TI A 17- 2;
TI A 17- 3; TI A 17- 4; TI A 17- 5; TI A 17- 6;
TI A 17- 7; TI A 17- 8; TI A 17- 9; TI A 17- 10;
TI A 17- 11; TI A 17- 12; TI A 17- 13; TI A
17- 14; TI A 17- 15; TI A 17- 16; TI A 17- 17 )
Nat i onal El ect r i cal Code
U. S. DEPARTMENT OF ENERGY ( DOE)
Ener gy St ar ( 1992; R 2006) Ener gy St ar Ener gy Ef f i c i ency Label i ng Syst em ( FEMP)
U. S. NATI ONAL ARCHI VES AND RECORDS ADMI NI STRATI ON ( NARA)
47 CFR 15 Radi o Fr equency Devi ces
UNDERWRI TERS LABORATORI ES ( UL)
UL 773 ( 2016; Repr i nt Nov 2017) UL St andar d f or Saf et y Pl ug- I n, Locki ng Type Phot ocont r ol s f or Use wi t h Ar ea Li ght i ng
UL 773A ( 2016; Repr i nt May 2018) UL St andar d f or Saf et y Noni ndust r i al Phot oel ect r i c Swi t ches f or Li ght i ng Cont r ol
UL 916 ( 2015) St andar d f or Ener gy Management Equipment
UL 1310 ( 2018) UL St andar d f or Saf et y Cl ass 2 Power Uni t s
UL 1598 ( 2008; Repr i nt Oct 2012) Lumi nai r es
UL 8750 ( 2015; Repr i nt Aug 2018) UL St andar d f or Saf et y Li ght Emi t t i ng Di ode ( LED) Equi pment f or Use i n Li ght i ng Pr oduct s
1. 2 RELATED REQUI REMENTS
Mat er i al s not consi der ed t o be l umi nai r es or l i ght i ng equi pment ar e speci f i ed i n Sect i on( s) 33 71 02 UNDERGROUND ELECTRI CAL DI STRI BUTI ON .
Lumi nai r es and accessor i es i nst al l ed i n i nt er i or of bui l di ngs ar e not r el evant t o t hi s pr oj ect .
1. 3 DEFINITIONS
a. Unl ess ot her wi se speci f i ed or i ndi cat ed, el ect r i cal and el ect r oni cs t er ms used i n t hese speci f i cat i ons, and on t he dr awi ngs shal l be as def i ned i n I EEE 100 and I ES RP- 16.
c. For LED l umi nai r e l i ght sour ces, " Usef ul Li f e" i s t he oper at i ng hour s bef or e r eachi ng 70 per cent of t he i ni t i al r at ed l umen out put ( L70) wi t h no cat ast r ophi c f ai l ur es under nor mal oper at i ng condi t i ons. Thi s i s al so known as 70 per cent " Rat ed Lumen Mai nt enance Li f e" as def i ned i n
I ES LM- 80.
SECTI ON 26 56 00 Page 3
1. 4 SUBMITTALS
Gover nment appr oval i s r equi r ed f or submi t t al s wi t h a " G" desi gnat i on;
submi t t al s not havi ng a " G" desi gnat i on ar e f or i nf or mat i on onl y. When used, a desi gnat i on f ol l owi ng t he " G" desi gnat i on i dent i f i es t he of f i ce t hat wi l l r evi ew t he submi t t al f or t he Gover nment . Submi t t al s wi t h an " S" ar e f or i ncl usi on i n t he Sust ai nabi l i t y eNot ebook, i n conf or mance wi t h Sect i on 01 33 29 SUSTAI NABI LI TY REPORTI NG. Submi t t he f ol l owi ng i n accor dance wi t h Sect i on 01 33 00 SUBMI TTAL PROCEDURES:
SD- 01 Pr econst r uct i on Submi t t al s
Phot omet r i c Pl an; G
LED Lumi nai r e War r ant y; G
SD- 02 Shop Dr awi ngs
Lumi nai r e Dr awi ngs; G
Pol es; G
SD- 03 Pr oduct Dat a
Ener gy St ar Label f or LED Lumi nai r e Pr oduct ; S
Lumi nai r e Li ght Sour ces; G
Lumi nai r e Power Suppl y Uni t s ( Dr i ver s) ; G
Li ght i ng Cont act or ; G
Ti me Swi t ch; G
Li ght i ng Cont r ol Rel ay Panel ; G
Mot i on Sensor ; G
Phot ocel l ; G
Concr et e Pol es; G
Al umi num Pol es; G
St eel Pol es; G
Brackets
Obst r uct i on Mar ker Lumi nai r es; G
SD- 04 Sampl es
SECTI ON 26 56 00 Page 4
LED, Lumi nai r es; G
Submi t one sampl e of each l umi nai r e t ype, compl et e wi t h l i ght sour ce and bal l ast , gener at or or power suppl y uni t . Submi t one sampl e f or each i t em ot her t han l umi nai r es. Sampl e wi l l be r et ur ned t o t he Cont r act or f or i nst al l at i on i n t he pr oj ect wor k.
SD- 05 Desi gn Dat a
Desi gn Dat a f or Lumi nai r es; G
SD- 06 Test Repor t s
LED Lumi nai r e - I ES LM- 79 Test Repor t ; G
LED Li ght Sour ce - I ES LM- 80 Test Repor t ; GOper at i ng Test
Submi t oper at i ng t est r esul t s as st at ed i n par agr aph ent i t l ed " Fi el d Qual i t y Cont r ol . "
SD- 07 Cer t i f i cat es
Lumi nai r e Usef ul Li f e Cer t i f i cat e; G
Submi t cer t i f i cat i on f r om t he manuf act ur er i ndi cat i ng t he expect ed usef ul l i f e of t he l umi nai r es pr ovi ded. The usef ul l i f e shal l be di r ect l y cor r el at ed f r om t he I ES LM- 80 t est dat a usi ng pr ocedur es out l i ned i n I ES TM- 21. Ther mal pr oper t i es of t he speci f i c l umi nai r e and l ocal ambi ent oper at i ng t emper at ur e and condi t i ons shal l be t aken i nt o consi der at i on.
SD- 08 Manuf act ur er ' s I nst r uct i ons
Concr et e Pol es
Submi t i nst r uct i ons pr i or t o i nst al l at i on.
Fi ber gl ass Pol es
Submi t i nst r uct i ons pr i or t o i nst al l at i on.
SD- 10 Oper at i on and Mai nt enance Dat a
El ect r oni c Bal l ast War r ant y
Oper at i onal Ser v i ce
Submi t document at i on t hat i ncl udes cont act i nf or mat i on, summar y of pr ocedur es, and t he l i mi t at i ons and condi t i ons appl i cabl e t o t he pr oj ect . I ndi cat e manuf act ur er ' s commi t ment t o r ecl ai m mat er i al s f or r ecycl i ng and/ or r euse.
1. 5 QUALI TY ASSURANCE
1. 5. 1 Dr awi ng Requi r ement s
1. 5. 1. 1 Lumi nai r e Dr awi ngs
I ncl ude di mensi ons, ef f ect i ve pr oj ect ed ar ea ( EPA) , accessor i es, and
SECTI ON 26 56 00 Page 5 i nst al l at i on and const r uct i on det ai l s . Phot omet r i c dat a, i ncl udi ng zonal l umen dat a, aver age and mi ni mum r at i o, ai mi ng di agr am, and comput er i zed candl epower di st r i but i on dat a shal l accompany shop dr awi ngs.
1. 5. 1. 2 Poles
I ncl ude di mensi ons, wi nd l oad det er mi ned i n accor dance wi t h AASHTO LTS, pol e def l ect i on, pol e c l ass, and ot her appl i cabl e i nf or mat i on.
1. 5. 2 Phot omet r i c Pl an
For LED and al l ot her t ypes of l umi nai r es, t he submi t t al shal l i ncl ude t he following:
Hor i zont al i l l umi nance measur ement s at f i ni shed gr ade, t aken at a maxi mum of ever y 10 f eet .
Ver t i cal i l l umi nance measur ement s at 5 f eet above f i ni shed gr ade.
Mi ni mum and maxi mum f oot candl e l evel s.
Aver age mai nt ai ned f oot candl e l evel .
Maxi mum t o mi ni mum r at i o f or hor i zont al i l l umi nance onl y.
1. 5. 3 Desi gn Dat a f or Lumi nai r es
a. Pr ovi de di st r i but i on dat a accor di ng t o I ES cl assi f i cat i on t ype as def i ned i n I ES HB- 10.
b. Shi el di ng as def i ned by I ES RP- 8 or B. U. G. r at i ng f or t he i nst al l ed posi t i on as def i ned by I ES TM- 15.
c. Pr ovi de saf et y cer t i f i cat i on and f i l e number f or t he l umi nai r e f ami l y.
I ncl ude l i s t i ng, l abel i ng and i dent i f i cat i on per NFPA 70 ( NEC) .
Appl i cabl e t est i ng bodi es ar e det er mi ned by t he US Occupat i onal Saf et y Heal t h Admi ni st r at i on ( OSHA) as Nat i onal l y Recogni zed Test i ng Labor at or i es ( NRTL) and i ncl ude: CSA ( Canadi an St andar ds Associ at i on) , ETL ( Edi son Test i ng Labor at or y) , and UL ( Under wr i t er s Labor at or i es) .
d. Pr ovi de l ong t er m l umen mai nt enance pr oj ect i ons f or each LED l umi nai r e i n accor dance wi t h I ES TM- 21. Dat a used f or pr oj ect i ons shal l be obt ai ned f r om t est i ng i n accor dance wi t h I ES LM- 80.
e. Pr ovi de wi nd l oadi ng cal cul at i ons f or l umi nai r es mount ed on pol es.
Wei ght and ef f ect i ve pr oj ect ed ar ea ( EPA) of l umi nai r es and mount i ng br acket s shal l not exceed maxi mum r at i ng of pol e as i nst al l ed i n par t i cul ar wi nd zone ar ea.
1. 5. 4 LED Lumi nai r e - I ES LM- 79 Test Repor t
Submi t t est r epor t on manuf act ur er ' s st andar d pr oduct i on model l umi nai r e.
Submi t t al shal l i ncl ude al l phot omet r i c and el ect r i cal measur ement s, as wel l as al l ot her per t i nent dat a out l i ned under " 14. 0 Test Repor t " i n
I ES LM- 79.
1. 5. 5 LED Li ght Sour ce - I ES LM- 80 Test Repor t
Submi t r epor t on manuf act ur er ' s st andar d pr oduct i on LED package, ar r ay, or
SECTI ON 26 56 00 Page 6 modul e. Submi t t al shal l i ncl ude:
a. Test i ng agency, r epor t number , dat e, t ype of equi pment , and LED l i ght sour ce bei ng t est ed.
b. Al l dat a r equi r ed by I ES LM- 80.
1. 5. 5. 1 Test Labor at or i es
Test l abor at or i es f or t he I ES LM- 79 and I ES LM- 80 t est r epor t s shal l be one of t he f ol l owi ng:
a. Nat i onal Vol unt ar y Labor at or y Accr edi t at i on Pr ogr am ( NVLAP) accr edi t ed f or sol i d- st at e l i ght i ng t est i ng as par t of t he Ener gy- Ef f i c i ent Li ght i ng Pr oduct s l abor at or y accr edi t at i on pr ogr am.
b. One of t he qual i f i ed l abs l i s t ed on t he Depar t ment of Ener gy - Ener gy Ef f i c i ency & Renewabl e Ener gy, Sol i d- St at e Li ght i ng web si t e.
c. A manuf act ur er ' s i n- house l ab t hat meet s t he f ol l owi ng cr i t er i a:
1. Manuf act ur er has been r egul ar l y engaged i n t he desi gn and pr oduct i on of hi gh i nt ensi t y di schar ge r oadway and ar ea l umi nai r es and t he manuf act ur er ' s l ab has been successf ul l y cer t i f y i ng t hese f i x t ur es f or a mi ni mum of 15 year s.
2. Annual equi pment cal i br at i on i ncl udi ng phot omet er cal i br at i on i n accor dance wi t h Nat i onal I nst i t ut e of St andar ds and Technol ogy.
1. 5. 6 Regul at or y Requi r ement s
I n each of t he publ i cat i ons r ef er r ed t o her ei n, consi der t he advi sor y pr ovi s i ons t o be mandat or y, as t hough t he wor d, " shal l " had been subst i t ut ed f or " shoul d" wher ever i t appear s. I nt er pr et r ef er ences i n t hese publ i cat i ons t o t he " aut hor i t y havi ng j ur i sdi ct i on, " or wor ds of s i mi l ar meani ng, t o mean t he Cont r act i ng Of f i cer . Equi pment , mat er i al s, i nst al l at i on, and wor kmanshi p shal l be i n accor dance wi t h t he mandat or y and advi sor y pr ovi s i ons of NFPA 70 unl ess mor e st r i ngent r equi r ement s ar e speci f i ed or i ndi cat ed.
1. 5. 7 St andar d Pr oduct s
Pr ovi de mat er i al s and equi pment t hat ar e pr oduct s of manuf act ur er s r egul ar l y engaged i n t he pr oduct i on of such pr oduct s whi ch ar e of equal mat er i al , desi gn and wor kmanshi p. Pr oduct s shal l have been i n sat i sf act or y commer ci al or i ndust r i al use f or 2 year s pr i or t o bi d openi ng. The 2- year per i od shal l i nc l ude appl i cat i ons of equi pment and mat er i al s under s i mi l ar c i r cumst ances and of s i mi l ar s i ze. The pr oduct shal l have been on sal e on t he commer ci al mar ket t hr ough adver t i sement s, manuf act ur er s ' cat al ogs, or br ochur es dur i ng t he 2- year per i od. Wher e t wo or mor e i t ems of t he same cl ass of equi pment ar e r equi r ed, t hese i t ems shal l be pr oduct s of a s i ngl e manuf act ur er ; however , t he component par t s of t he i t em need not be t he pr oduct s of t he same manuf act ur er unl ess st at ed i n t hi s sect i on.
1. 5. 7. 1 Al t er nat i ve Qual i f i cat i ons
Pr oduct s havi ng l ess t han a 2- year f i el d ser vi ce r ecor d wi l l be accept abl e i f t he manuf act ur er has been r egul ar l y engaged i n t he desi gn and pr oduct i on of hi gh i nt ensi t y di schar ge r oadway and ar ea l umi nai r es f or a mi ni mum of 15
SECTI ON 26 56 00 Page 7 year s. Pr oduct s shal l have been i n sat i sf act or y commer ci al or i ndust r i al use f or 15 year s pr i or t o bi d openi ng. The pr oduct shal l have been on sal e on t he commer ci al mar ket t hr ough adver t i sement s, manuf act ur er s ' cat al ogs, or br ochur es dur i ng t he 15- year per i od.
1. 5. 7. 2 Mat er i al and Equi pment Manuf act ur i ng Dat e
Pr oduct s manuf act ur ed mor e t han 1 year pr i or t o dat e of del i ver y t o s i t e shal l not be used, unl ess speci f i ed ot her wi se.
1. 6 WARRANTY
The equi pment i t ems shal l be suppor t ed by ser vi ce or gani zat i ons whi ch ar e r easonabl y conveni ent t o t he equi pment i nst al l at i on i n or der t o r ender sat i sf act or y ser vi ce t o t he equi pment on a r egul ar and emer gency basi s dur i ng t he war r ant y per i od of t he cont r act .
1. 6. 1 LED Lumi nai r e War r ant y
Pr ovi de Lumi nai r e Usef ul Li f e Cer t i f i cat e.
The equi pment i t ems shal l be suppor t ed by ser vi ce or gani zat i ons whi ch ar e r easonabl y conveni ent t o t he equi pment i nst al l at i on i n or der t o r ender sat i sf act or y ser vi ce t o t he equi pment on a r egul ar and emer gency basi s dur i ng t he war r ant y per i od of t he cont r act .
a. Pr ovi de a wr i t t en f i ve year on- si t e r epl acement war r ant y f or mat er i al , f i x t ur e f i ni sh, and wor kmanshi p. On- si t e r epl acement i ncl udes t r anspor t at i on, r emoval , and i nst al l at i on of new pr oduct s.
1. Fi ni sh war r ant y shal l i ncl ude war r ant y agai nst f ai l ur e and agai nst subst ant i al det er i or at i on such as bl i s t er i ng, cr acki ng, peel i ng, chal k i ng, or f adi ng.
2. Mat er i al war r ant y shal l i ncl ude:
( a) Al l power suppl y uni t s ( dr i ver s) .
( b) Repl acement when mor e t han 10 per cent of LED sour ces i n any l i ght bar or subassembl y( s) ar e def ect i ve or non- st ar t i ng.
b. War r ant y per i od must begi n on dat e of benef i c i al occupancy. Cont r act or shal l pr ovi de t he Cont r act i ng Of f i cer s i gned war r ant y cer t i f i cat es pr i or t o f i nal payment .
1. 6. 2 El ect r oni c Bal l ast War r ant y
Fur ni sh t he el ect r oni c bal l ast s manuf act ur er ' s war r ant y. The war r ant y per i od shal l not be l ess t han f i ve ( 5) year s f r om t he dat e of manuf act ur e.
Bal l ast assembl y i n t he l i ght i ng f i x t ur e, t r anspor t at i on, and on- si t e st or age shal l not exceed t wel ve ( 12) mont hs, t her eby per mi t t i ng f our ( 4) year s of t he f i ve ( 5) year war r ant y t o be i n ser vi ce and ener gi zed. The war r ant y shal l s t at e t hat t he mal f unct i oni ng bal l ast shal l be exchanged by t he manuf act ur er and pr ompt l y shi pped t o t he usi ng Gover nment f aci l i t y .
The r epl acement bal l ast shal l be i dent i cal t o, or an i mpr ovement upon, t he or i gi nal desi gn of t he mal f unct i oni ng bal l ast .
SECTI ON 26 56 00 Page 8
1. 7 OPERATI ONAL SERVI CE
Coor di nat e wi t h manuf act ur er f or mai nt enance agr eement . Col l ect i nf or mat i on f r om t he manuf act ur er about mai nt enance agr eement opt i ons, and submi t t o Cont r act i ng Of f i cer . Ser vi ces shal l r ec l ai m mat er i al s f or r ecycl i ng and/ or r euse. Ser vi ces shal l not deposi t mat er i al s i n l andf i l l s or bur n r ecl ai med mat er i al s. I ndi cat e pr ocedur es f or compl i ance wi t h r egul at i ons gover ni ng di sposal of mer cur y. When such a ser vi ce i s not avai l abl e, l ocal r ecycl er s shal l be sought af t er t o r ecl ai m t he mat er i al s.
PART 2 PRODUCTS
2. 1 LED, LUMI NAI RES
UL 1598, NEMA C82. 77 and UL 8750. Pr ovi de l umi nai r es as i ndi cat ed i n l umi nai r e schedul e and XL pl at es or det ai l s on pr oj ect pl ans. Pr ovi de l umi nai r es compl et e wi t h l i ght sour ces of quant i t y , t ype, and wat t age i ndi cat ed. Al l l umi nai r es of t he same t ype shal l be pr ovi ded by t he same manuf act ur er . Pr ovi de Ener gy St ar l abel ed LED l umi nai r e pr oduct . Pr ovi de pr oof of Ener gy St ar l abel f or LED l umi nai r e pr oduct .
2. 1. 1 Gener al Requi r ement s
a. LED l umi nai r e housi ngs shal l be di e cast or ext r uded al umi num.
b. LED l umi nai r es shal l be r at ed f or oper at i on wi t hi n an ambi ent t emper at ur e r ange of mi nus 22 degr ees F t o 122 degr ees F.
c. Lumi nai r es shal l be UL l i s t ed f or wet l ocat i ons per UL 1598. Opt i cal compar t ment f or LED l umi nai r es shal l be seal ed and r at ed a mi ni mum of I P65 per NEMA I EC 60529.
d. LED l umi nai r es shal l pr oduce a mi ni mum ef f i cacy as shown i n t he f ol l owi ng t abl e, t est ed per I ES LM- 79. Theor et i cal model s of i ni t i al r aw LED l umens per wat t ar e not accept abl e.
Application Lumi nai r e Ef f i cacy i n Lumens per Wat t
Ext er i or Pol e/ Ar m- Mount ed Ar ea and Roadway Luminaires
Ext er i or Pol e/ Ar m- Mount ed Decor at i ve Luminaires
Ext er i or Wal l - Mount ed Ar ea Lumi nai r es 102
Bollards 45
Par ki ng Gar age Lumi nai r es 106
e. Lumi nai r es shal l have I ES di st r i but i on and NEMA f i el d angl e c l assi f i cat i ons as i ndi cat ed i n l umi nai r e schedul e on pr oj ect pl ans per
I ES HB- 10.
f . Housi ng f i ni sh shal l be baked- on enamel , anodi zed, or baked- on powder coat pai nt . Fi ni sh shal l be capabl e of sur vi v i ng ASTM B117 sal t f og
SECTI ON 26 56 00 Page 9 envi r onment t est i ng f or 2500 hour s mi ni mum wi t hout bl i s t er i ng or peeling.
g. Lumi nai r es shal l not exceed t he f ol l owi ng I ES TM- 15 Backl i ght , Upl i ght and Gl ar e ( B. U. G. ) r at i ngs:
1. Maxi mum Backl i ght ( B) r at i ng shal l be det er mi ned by l i ght i ng zone i n whi ch l umi nai r e i s pl aced.
2. Maxi mum Upl i ght ( U) r at i ng shal l be U0.
3. Maxi mum Gl ar e ( G) r at i ng shal l be det er mi ned by l i ght i ng zone i n whi ch l umi nai r e i s pl aced.
h. Lumi nai r es shal l be f ul l y assembl ed and el ect r i cal l y t est ed pr i or t o shi pment f r om f act or y.
i . The f i ni sh col or shal l be as i ndi cat ed i n t he l umi nai r e schedul e or det ai l on t he pr oj ect pl ans.
j . Lumi nai r e ar m bol t s shal l be 304 st ai nl ess st eel or z i nc- pl at ed st eel .
k. Lumi nai r e l enses shal l be const r uct ed of c l ear t emper ed gl ass or UV- r esi st ant acr yl i c . Pr ovi de pol ycar bonat e vandal - r esi st ant l enses as indicated.
l . The wi r i ng compar t ment on pol e- mount ed, st r eet and ar ea l umi nai r es must be accessi bl e wi t hout t he use of hand t ool s t o mani pul at e smal l scr ews, bol t s, or har dwar e.
m. I ncor por at e modul ar el ect r i cal connect i ons, and const r uct l umi nai r es t o al l ow r epl acement of al l or any par t of t he opt i cs, heat s i nks, power suppl y uni t s, bal l ast s, sur ge suppr essor s and ot her el ect r i cal component s usi ng onl y a s i mpl e t ool , such as a manual or cor dl ess el ect r i c scr ewdr i ver .
n. Lumi nai r es shal l have a namepl at e bear i ng t he manuf act ur er ' s name, addr ess, model number , dat e of manuf act ur e, and ser i al number secur el y af f i xed i n a conspi cuous pl ace. The namepl at e of t he di st r i but i ng agent wi l l not be accept abl e.
o. Roadway and ar ea l umi nai r es shal l have an i nt egr al t i l t adj ust ment of pl us or mi nus 5 degr ees t o al l ow t he uni t t o be l evel ed i n accor dance with ANSI C136. 3.
p. Lumi nai r e must pass 3G vi br at i on t est i ng i n accor dance wi t h NEMA C136. 31.
q. Al l f act or y el ect r i cal connect i ons shal l be made usi ng cr i mp, l ocki ng, or l at chi ng st y l e connect or s. Twi st - st y l e wi r e nut s ar e not accept abl e.
2. 1. 2 Lumi nai r e Li ght Sour ces
2. 1. 2. 1 LED Li ght Sour ces
a. Cor r el at ed Col or Temper at ur e ( CCT) shal l be i n accor dance wi t h
NEMA ANSLG C78. 377:
SECTI ON 26 56 00 Page 10
Nomi nal CCT: 4000 degr ees K: 3985 pl us or mi nus 275 degr ees K
b. Col or Render i ng I ndex ( CRI ) shal l be:
Gr eat er t han or equal t o 70 f or 4000 degr ees K l i ght sour ces.
c. Col or Consi st ency:
Manuf act ur er shal l ut i l i ze a maxi mum 4- st ep MacAdam el l i pse bi nni ng t ol er ance f or col or consi st ency of LEDs used i n l umi nai r es.
2. 1. 3 Lumi nai r e Power Suppl y Uni t s ( Dr i ver s)
2. 1. 3. 1 LED Power Suppl y Uni t s ( Dr i ver s)
UL 1310. LED Power Suppl y Uni t s ( Dr i ver s) shal l meet t he f ol l owi ng requirements:
a. Mi ni mum ef f i c i ency shal l be 85 per cent .
b. Dr i ve cur r ent t o each i ndi v i dual LED shal l not exceed 600 mA, pl us or mi nus 10 per cent .
c. Shal l be r at ed t o oper at e bet ween ambi ent t emper at ur es of mi nus 22 degr ees F and 104 degr ees F.
d. Shal l be desi gned t o oper at e on t he vol t age syst em t o whi ch t hey ar e connect ed, t ypi cal l y r angi ng f r om 120 V t o 480 V nomi nal .
e. Oper at i ng f r equency shal l be: 50 or 60 Hz.
f . Power Fact or ( PF) shal l be gr eat er t han or equal t o 0. 90.
g. Tot al Har moni c Di st or t i on ( THD) cur r ent shal l be l ess t han or equal t o 20 per cent .
h. Shal l meet r equi r ement s of 47 CFR 15, Cl ass B.
i . Shal l be RoHS- compl i ant .
j . Shal l be mount ed i nt egr al t o l umi nai r e. Remot e mount i ng of power suppl y i s not al l owed.
k. Power suppl i es i n l umi nai r es mount ed under a cover ed st r uct ur e, such as a canopy, or wher e ot her wi se appr opr i at e shal l be UL l i s t ed wi t h a sound r at i ng of A.
l . Shal l be di mmabl e, and compat i bl e wi t h a st andar d di mmi ng cont r ol c i r cui t of 0 - 10V or ot her appr oved di mmi ng syst em.
m. Shal l be equi pped wi t h over - t emper at ur e pr ot ect i on c i r cui t t hat t ur ns l i ght sour ce of f unt i l nor mal oper at i ng t emper at ur e i s achi eved.
2. 1. 4 LED Lumi nai r e Sur ge Pr ot ect i on
Pr ovi de sur ge pr ot ect i on i nt egr al t o l umi nai r e t o meet C Low wavef or ms as def i ned by I EEE C62. 41. 2, Scenar i o 1, Locat i on Cat egor y C.
SECTI ON 26 56 00 Page 11
2. 2 OBSTRUCTI ON MARKER LUMI NAI RES
Pr ovi de obst r uct i on mar ker l umi nai r es f or f aci l i t i es as r equi r ed by t he FAA and i n accor dance wi t h Sect i on 26 56 20 AI RFI ELD AND HELI PORT LI GHTI NG AND
VI SUAL NAVI GATI ON AI DS.
2. 3 EXTERI OR LUMI NAI RE CONTROLS
Cont r ol s shal l compl y wi t h Sect i on 9 of ASHRAE 90. 1 - I P . Pr ovi de a cont r ol syst em i nt er f ace wi t hi n each l umi nai r e t hat i s compat i bl e wi t h t he ener gy management or cont r ol syst em used by t he ut i l i t y depar t ment i n char ge of t he pr oj ect ar ea f or cont r ol of s i t e l i ght i ng.
2. 3. 1 Photocell
UL 773 or UL 773A. Phot ocel l s shal l be her met i cal l y seal ed, s i l i con di ode l i ght sensor t ype, r at ed at 3000 wat t s, 277 vol t s, 50/ 60 Hz wi t h s i ngl e- pol e, s i ngl e- t hr ow cont act s. Phot ocel l shal l be desi gned t o f ai l t o t he ON posi t i on. Housi ng shal l be const r uct ed of pol ycar bonat e , r at ed t o oper at e wi t hi n a t emper at ur e r ange of mi nus 40 t o 158 degr ees F. Phot ocel l shal l have a 1/ 2 i n t hr eaded base f or mount i ng t o a j unct i on box or condui t . Pr ovi de f i xed base t ype housi ng. Phot ocel l shal l t ur n on at 1- 3 f oot candl es and t ur n of f at 3 t o 15 f oot candl es. A t i me del ay shal l pr event acci dent al swi t chi ng f r om t r ansi ent l i ght sour ces. Pr ovi de a di r ect i onal l ens i n f r ont of t he cel l t o pr event f i xed l i ght sour ces f r om cr eat i ng a t ur nof f condi t i on.
2. 3. 2 Timeswitch
Ti meswi t ch shal l be an el ect r oni c t ype wi t h a 7 day pr ogr ammi ng f unct i on t hat changes on/ of f set t i ngs accor di ng t o seasonal var i at i ons of sunset and sunr i se, pr ovi di ng a t ot al of 56 on/ of f set poi nt s. Di gi t al c l ock di spl ay f or mat shal l be24 hour t ype. Pr ovi de power out age backup f or swi t ch ut i l i z i ng a al kal i ne bat t er i es whi ch pr ovi des cover age f or a mi ni mum of 7 days. Ti meswi t ch shal l pr ovi de cont r ol t o 2 channel s or l oads. Cont act s shal l be r at ed f or 30 amps at 120- 277 VAC r esi st i ve l oad i n a SPST conf i gur at i on. Pr ovi de swi t ch wi t h f unct i on t hat al l ows aut omat i c cont r ol t o be ski pped on cer t ai n sel ect ed days of t he weekdayl i ght savi ngs t i me aut omat i c adj ust ment abi l i t y f or phot osensor i nput .
Ti meswi t ch shal l be housed i n a sur f ace- mount ed, l ockabl e NEMA 3R encl osur e const r uct ed of pai nt ed st eel or pl ast i c pol ymer conf or mi ng t o NEMA I CS 6.
2. 3. 3 Li ght i ng Cont act or
NEMA I CS 2. Pr ovi de a el ect r i cal l y- hel d l i ght i ng cont act or housed i n a NEMA 3R encl osur e conf or mi ng t o NEMA I CS 6. Cont act or shal l have 4 pol es, conf i gur ed as nor mal l y open ( NO) . Cont act s shal l be r at ed 600 vol t s, 30 amper es f or a r esi st i ve l oad. Coi l oper at i ng vol t age shal l be 277 vol t s.
Cont act or shal l have s i l ver cadmi um oxi de doubl e- br eak cont act s and coi l c l ear i ng cont act s f or mechani cal l y hel d cont act or s and shal l r equi r e no ar ci ng cont act s. Pr ovi de cont act or wi t h hand- of f - aut omat i c on- of f sel ect or swi t ch.
2. 3. 4 Li ght i ng Cont r ol Rel ay Panel
Panel shal l consi st of a s i ngl e NEMA 3R - mount ed encl osur e wi t h t wo
SECTI ON 26 56 00 Page 12 separ at e i nt er i or sect i ons; one f or Cl ass 1 ( br anch ci r cui t ) and one f or Cl ass 2 ( l ow vol t age) wi r i ng. Pr ovi de panel wi t h 16 r el ays. Panel shal l be desi gned as an aut omat ed cont r ol syst em i nt er f ace t ype. The Cl ass 1 sect i on shal l cont ai n t he l oad s i de of al l r el ays and t he i ncomi ng br anch ci r cui t wi r i ng. The Cl ass 2 sect i on shal l cont ai n t he cont r ol power t r ansf or mer ( 24 vol t out put ) , r el ays, r el ay cont r ol modul es, and cont r ol wi r i ng, and nat i ve BACnet f i el d- pr ogr ammabl e appl i cat i on cont r ol l er f or panel s connect ed t o t he f aci l i t y aut omat ed cont r ol syst em. Panel encl osur e shal l be const r uct ed of 16 gauge col d- r ol l ed st eel wi t h baked- on enamel f i ni sh. Panel shal l meet r equi r ement s of UL 916, ASHRAE 90. 1 - I P, and
47 CFR 15.
Rel ays shal l be 1- pol e, r at ed at 20 amper es 300 VAC wi t h r at ed l i f e of 120, 000 mechani cal oper at i ons mi ni mum.
Rel ay cont r ol modul e shal l be 24 vol t , el ect r oni c t ype and cont r ol up t o 16 separ at e r el ays ( 16 channel ) or pr ogr ammed gr oups of r el ays. Pr ovi de wi t h i nput s f or s i gnal s f r om devi ces such as phot ocel l s , t i mecl ocks, and mot i on sensor s. Rel ay cont r ol modul e wi t h i nt egr al t i mecl ock f unct i on shal l be 24 vol t , el ect r oni c t ype wi t h LCD di spl ay and cont r ol up t o 8 separ at e r el ays ( 8 channel ) .
2. 3. 5 Mot i on Sensor
NEMA WD 7, UL 773A. Pr ovi de dual t echnol ogy passi ve i nf r ar ed/ mi cr owave t ype sensor s wi t h 270 degr ee cover age, t i me del ay t hat can be adj ust ed f r om 15 seconds t o 15 mi nut es, and " f ai l t o ON posi t i on" def aul t st at e. Sensor s shal l be l ocat ed t o achi eve cover age of ar eas as i ndi cat ed on pr oj ect pl ans. Cover age pat t er ns shal l be der at ed as r ecommended by manuf act ur er based on mount i ng hei ght of sensor and any obst r uct i ons such as t r ees. Do not use gr oss r at ed cover age i n manuf act ur er ' s pr oduct l i t er at ur e. Sensor s i nst al l ed i nt egr al t o t he l umi nai r e must be pr ovi ded by t he l umi nai r e manuf act ur er . Sensor s shal l have an i nt egr al l i ght l evel sensor t hat does not al l ow l umi nai r es t o oper at e dur i ng dayl i ght hour s and shal l be desi gned t o oper at e on a vol t age of 120/ 277 VAC. Pr ovi de sensor s t o oper at e i n conj unct i on wi t h bi - l evel cont r ol l er s t hat l ower HI D or LED l umi nai r es t o a 50 per cent out put . Sensor shal l be mount ed di r ect l y t o l umi nai r e.
2. 4 POLES
Pr ovi de pol es desi gned f or wi nd l oadi ng of 100 mi l es per hour det er mi ned i n accor dance wi t h AASHTO LTS whi l e suppor t i ng l umi nai r es and al l ot her appur t enances i ndi cat ed. The ef f ect i ve pr oj ect ed ar eas of l umi nai r es and appur t enances used i n cal cul at i ons shal l be speci f i c f or t he act ual pr oduct s pr ovi ded on each pol e. Pol es shal l be embedded- base t ype desi gned f or use wi t h under gr ound suppl y conduct or s. Pol es shal l have oval - shaped handhol e havi ng a mi ni mum cl ear openi ng of 2. 5 by 5 i nches. Handhol e cover shal l be secur ed by st ai nl ess st eel capt i ve scr ews. Met al pol es shal l have an i nt er nal gr oundi ng connect i on accessi bl e f r om t he handhol e near t he bot t om of each pol e. Scr at ched, st ai ned, chi pped, or dent ed pol es shal l not be i nst al l ed.
2. 4. 1 St eel Pol es
AASHTO LTS. Pr ovi de st eel pol es havi ng mi ni mum 11- gage st eel wi t h mi ni mum yi el d/ st r engt h of 48, 000 psi and hot - di pped gal vani zed i n accor dance wi t h ASTM A123/ A123M f act or y f i ni sh. Pr ovi de a pol e gr oundi ng connect i on desi gned t o pr event el ect r ol ysi s when used wi t h copper gr ound wi r e. Pol e shal l be di r ect set t ype. Pol es shal l have t aper ed t ubul ar member s, ei t her
SECTI ON 26 56 00 Page 13 r ound i n cr oss sect i on or pol ygonal . Pol e shaf t s shal l be one pi ece.
Pol es shal l be wel ded const r uct i on wi t h no bol t s, r i vet s, or ot her means of f ast eni ng except as speci f i cal l y appr oved. Pol e mar ki ngs shal l be appr oxi mat el y 3 t o 4 f eet above gr ade and shal l i ncl ude manuf act ur er , year of manuf act ur e, t op and bot t om di amet er s, and l engt h. Base cover s f or st eel pol es shal l be st r uct ur al qual i t y hot - r ol l ed car bon st eel pl at e havi ng a mi ni mum yi el d of 36, 000 psi .
2. 5 BRACKETS AND SUPPORTS
ANSI C136. 3, ANSI C136. 13, and ANSI C136. 21, as appl i cabl e. Pol e br acket s shal l be not l ess t han 1 1/ 4 i nch gal vani zed st eel pi pe secur ed t o pol e.
Sl i p- f i t t er or pi pe- t hr eaded br acket s may be used, but br acket s shal l be coor di nat ed t o l umi nai r es pr ovi ded, and br acket s f or use wi t h one t ype of l umi nai r e shal l be i dent i cal . Br acket s f or pol e- mount ed st r eet l i ght s shal l cor r ect l y posi t i on l umi nai r e no l ower t han mount i ng hei ght i ndi cat ed. Mount br acket s not l ess t han 24 f eet above st r eet . Speci al mount i ngs or br acket s shal l be as i ndi cat ed and shal l be of met al whi ch wi l l not pr omot e gal vani c r eact i on wi t h l umi nai r e head.
2. 6 POLE FOUNDATI ONS
Anchor bol t s shal l be st eel r od havi ng a mi ni mum yi el d st r engt h of 50, 000 psi ; t he t op 12 i nches of t he r od shal l be gal vani zed i n accor dance wi t h ASTM A153/ A153M. Concr et e shal l be as speci f i ed i n Sect i on 03 30 00
CAST- I N- PLACE CONCRETE.
2. 7 EQUI PMENT I DENTI FI CATI ON
2. 7. 1 Manuf act ur er ' s Namepl at e
Each i t em of equi pment shal l have a namepl at e bear i ng t he manuf act ur er ' s name, addr ess, model number , and ser i al number secur el y af f i xed i n a conspi cuous pl ace; t he namepl at e of t he di st r i but i ng agent wi l l not be acceptable.
2. 7. 2 Labels
Pr ovi de l abel ed l umi nai r es i n accor dance wi t h UL 1598 r equi r ement s.
Lumi nai r es shal l be c l ear l y mar ked f or oper at i on of speci f i c l i ght sour ces and bal l ast s accor di ng t o pr oper l i ght sour ce t ype. The f ol l owi ng l i ght sour ce char act er i st i cs shal l be not ed i n t he f or mat " Use Onl y _____" :
a. Li ght sour ce t ube di amet er code ( e. g. T- 5, T- 8) , t ube quant i t y conf i gur at i on ( e. g. t wi n, quad, t r i pl e) , base t ype ( e. g. G24q- 2, GX 24 q- 4) , and nomi nal wat t age f or f l uor escent and compact f l uor escent luminaires.
b. Li ght sour ce t ype, wat t age, bul b t ype ( e. g. ED17, BD56) and coat i ng ( c l ear or coat ed) f or HI D l umi nai r es.
c. St ar t t ype ( e. g. pr ogr ammed- st ar t , r api d- st ar t , i nst ant - st ar t ) f or f l uor escent and compact f l uor escent l umi nai r es.
d. ANSI bal l ast t ype ( e. g. M98, M57) f or HI D l umi nai r es.
e. Cor r el at ed col or t emper at ur e ( CCT) and col or r ender i ng i ndex ( CRI ) f or al l l umi nai r es.
SECTI ON 26 56 00 Page 14
Mar ki ngs r el at ed t o l amp t ype shal l be c l ear and l ocat ed t o be r eadi l y v i s i bl e t o ser vi ce per sonnel , but unseen f r om nor mal v i ewi ng angl es when l amps ar e i n pl ace.
2. 8 FACTORY APPLI ED FI NI SH
El ect r i cal equi pment shal l have f act or y- appl i ed pai nt i ng syst ems whi ch shal l , as a mi ni mum, meet t he r equi r ement s of NEMA 250 cor r osi on- r esi st ance test.
PART 3 EXECUTI ON
3. 1 INSTALLATION
El ect r i cal i nst al l at i ons shal l conf or m t o I EEE C2, NFPA 70, and t o t he r equi r ement s speci f i ed her ei n.
3. 1. 1 St eel Pol es
Pr ovi de pol e f oundat i ons wi t h gal vani zed st eel anchor bol t s, t hr eaded at t he t op end and bent 90 degr ees at t he bot t om end. Pr ovi de or nament al cover s t o mat ch pol e and gal vani zed nut s and washer s f or anchor bol t s.
Concr et e f or anchor bases, pol yvi nyl chl or i de ( PVC) condui t el l s , and gr ound r ods shal l be as speci f i ed i n Sect i on 33 71 02 UNDERGROUND ELECTRI CAL DI STRI BUTI ON. Thor oughl y compact backf i l l wi t h compact i ng ar r anged t o pr event pr essur e bet ween conduct or , j acket , or sheat h and t he end of condui t el l . Adj ust pol es as necessar y t o pr ovi de a per manent ver t i cal posi t i on wi t h t he br acket ar m i n pr oper posi t i on f or l umi nai r e location.
3. 1. 2 Pol e Set t i ng
Pol es i n st r ai ght r uns shal l be i n a st r ai ght l i ne. Di g hol es l ar ge enough t o per mi t t he pr oper use of t amper s t o t he f ul l dept h of t he hol e. Pl ace backf i l l i n t he hol e i n 6 i nch maxi mum l ayer s and t hor oughl y t amp. Pl ace sur pl us ear t h ar ound t he pol e i n a coni cal shape and pack t i ght l y t o dr ai n wat er away.
3. 1. 3 Phot ocel l Swi t ch Ai mi ng
Ai m swi t ch accor di ng t o manuf act ur er ' s r ecommendat i ons. Mount swi t ch on or besi de each l umi nai r e when swi t ch i s pr ovi ded i n cast weat her pr oof al umi num housi ng wi t h swi vel ar m.
3. 1. 4 GROUNDING
Gr ound noncur r ent - car r y i ng par t s of equi pment i ncl udi ng met al pol es, l umi nai r es, mount i ng ar ms, br acket s, and met al l i c encl osur es as speci f i ed i n Sect i on 33 71 02 UNDERGROUND ELECTRI CAL DI STRI BUTI ON. Wher e copper gr oundi ng conduct or i s connect ed t o a met al ot her t han copper , pr ovi de speci al l y t r eat ed or l i ned connect or s sui t abl e f or t hi s pur pose.
3. 1. 5 FI ELD APPLI ED PAI NTI NG
Pai nt el ect r i cal equi pment as r equi r ed t o mat ch f i ni sh of adj acent sur f aces or t o meet t he i ndi cat ed or speci f i ed saf et y cr i t er i a. Pai nt i ng shal l be
SECTI ON 26 56 00 Page 15 as speci f i ed i n Sect i on 09 90 00 PAI NTS AND COATI NGS.
3. 2 FI ELD QUALI TY CONTROL
Upon compl et i on of i nst al l at i on, ver i f y t hat equi pment i s pr oper l y i nst al l ed, connect ed, and adj ust ed. Conduct an oper at i ng t est af t er 100 hour s of bur n- i n t i me t o show t hat t he equi pment oper at es i n accor dance wi t h t he r equi r ement s of t hi s sect i on.
- - End of Sect i on - -
SECTI ON 26 56 00 Page 16
SECTI ON 26 56 13. 00 40
LI GHTI NG POLES AND STANDARDS
11/14
PART 1 GENERAL
1. 1 REFERENCES
The publ i cat i ons l i s t ed bel ow f or m a par t of t hi s speci f i cat i on t o t he ext ent r ef er enced. The publ i cat i ons ar e r ef er r ed t o wi t hi n t he t ext by t he basi c desi gnat i on onl y.
AMERI CAN ASSOCI ATI ON OF STATE HI GHWAY AND TRANSPORTATI ON OFFI CI ALS
(AASHTO)
AASHTO LTS ( 2013; Er r at a 2013) St andar d Speci f i cat i ons f or St r uct ur al Suppor t s f or Hi ghway Si gns, Lumi nai r es and Tr af f i c Signals
ASTM I NTERNATI ONAL ( ASTM)
ASTM A36/ A36M ( 2014) St andar d Speci f i cat i on f or Car bon St r uct ur al St eel
ASTM A153/ A153M ( 2016) St andar d Speci f i cat i on f or Zi nc Coat i ng ( Hot - Di p) on I r on and St eel Hardware
ASTM A575 ( 1996; E 2013; R 2013) St andar d Speci f i cat i on f or St eel Bar s, Car bon, Mer chant Qual i t y , M- Gr ades
ASTM A576 ( 2017) St andar d Speci f i cat i on f or St eel Bar s, Car bon, Hot - Wr ought , Speci al Qual i t y
I LLUMI NATI NG ENGI NEERI NG SOCI ETY ( I ES)
I ES HB- 10 ( 2011; Er r at a 2015) I ES Li ght i ng Handbook
I NSTI TUTE OF ELECTRI CAL AND ELECTRONI CS ENGI NEERS ( I EEE)
I EEE 81 ( 2012) Gui de f or Measur i ng Ear t h Resi st i v i t y, Gr ound I mpedance, and Ear t h Sur f ace Pot ent i al s of a Gr ound Syst em
I EEE C2 ( 2017; Er r at a 1- 2 2017; I NT 1 2017) Nat i onal El ect r i cal Saf et y Code
I EEE C135. 1 ( 1999) St andar d f or Zi nc- Coat ed St eel Bol t s and Nut s f or Over head Li ne Construction
I EEE St ds Di ct i onar y ( 2009) I EEE St andar ds Di ct i onar y: Gl ossar y of Ter ms & Def i ni t i ons
SECTI ON 26 56 13. 00 40 Page 1
NATI ONAL ELECTRI CAL MANUFACTURERS ASSOCI ATI ON ( NEMA)
ANSI C136. 3 ( 2014) Amer i can Nat i onal St andar d f or Roadway and Ar ea Li ght i ng Equi pment Lumi nai r e At t achment s
ANSI C136. 13 ( 2014) Roadway and Ar ea Li ght i ng Equi pment
- Met al Br acket s f or Wood Pol es
ANSI C136. 21 ( 2014) Amer i can Nat i onal St andar d f or Roadway and Ar ea Li ght i ng Equi pment - Ver t i cal Tenons Used wi t h Post - Top- Mount ed Luminaires
NEMA C136. 20 ( 2012) Amer i can Nat i onal St andar d f or Roadway and Ar ea Li ght i ng Equi pment - Fi ber Rei nf or ced Composi t e ( FRC) Li ght i ng Poles
NATI ONAL FI RE PROTECTI ON ASSOCI ATI ON ( NFPA)
NFPA 70 ( 2017; ERTA 1- 2 2017; TI A 17- 1; TI A 17- 2;
TI A 17- 3; TI A 17- 4; TI A 17- 5; TI A 17- 6;
TI A 17- 7; TI A 17- 8; TI A 17- 9; TI A 17- 10;
TI A 17- 11; TI A 17- 12; TI A 17- 13; TI A
17- 14; TI A 17- 15; TI A 17- 16; TI A 17- 17 )
Nat i onal El ect r i cal Code
SOCI ETY FOR PROTECTI VE COATI NGS ( SSPC)
SSPC SP 10/ NACE No. 2 ( 2007) Near - Whi t e Bl ast Cl eani ng
U. S. GENERAL SERVI CES ADMI NI STRATI ON ( GSA)
FS TT- P- 38 ( Rev E; Not i ce 1) Pai nt , Al umi num, Ready-Mixed
FS TT- P- 645 ( Rev C) Pr i mer , Pai nt , Zi nc- Mol ybdat e, Al kyd Type
UNDERWRI TERS LABORATORI ES ( UL)
UL 467 ( 2013; Repr i nt Jun 2017) UL St andar d f or Saf et y Gr oundi ng and Bondi ng Equi pment
1. 2 DEFINITIONS
Gr oundl i ne sect i on i s t hat por t i on bet ween one f oot above and 2 f eet bel ow t he gr oundl i ne. Ref er t o I EEE St ds Di ct i onar y f or addi t i onal r el at ed def i ni t i ons and t er mi nol ogy.
1. 3 ADMI NI STRATI VE REQUI REMENTS
1. 3. 1 Sust ai nabl e Desi gn Requi r ement s
Use mat er i al s or pr oduct s ext r act ed, har vest ed, or r ecover ed, as wel l as manuf act ur ed, wi t hi n a 500 mi l e r adi us f r om t he pr oj ect s i t e, i f avai l abl e f r om a mi ni mum of t hr ee sour ces.
SECTI ON 26 56 13. 00 40 Page 2
Submi t document at i on i ndi cat i ng di st ance bet ween manuf act ur i ng f aci l i t y and t he pr oj ect s i t e. I ndi cat e di st ance of r aw mat er i al or i gi n f r om t he pr oj ect s i t e. I ndi cat e r el at i ve dol l ar val ue of l ocal / r egi onal mat er i al s t o t ot al dol l ar val ue of pr oduct s i ncl uded i n pr oj ect .
a. Local / Regi onal Mat er i al s
b. Sust ai nabl e acqui s i t i on
c. Envi r onment al Dat a
Submi t document at i on t hat i ncl udes cont act i nf or mat i on, summar y of pr ocedur es, and t he l i mi t at i ons and condi t i ons appl i cabl e t o t he pr oj ect .
I ndi cat e manuf act ur er ' s commi t ment t o r ecl ai m mat er i al s f or r ecycl i ng and/ or r euse.
a. Oper at i onal Ser vi ce
Coor di nat e wi t h manuf act ur er f or mai nt enance agr eement . Col l ect i nf or mat i on f r om t he manuf act ur er about mai nt enance agr eement opt i ons, and submi t t o t he Cont r act i ng Of f i cer . Mai nt enance agr eement f or ser vi ces t o r ecl ai m mat er i al s f or r ecycl i ng and/ or r euse may not be used f or l andf i l l or bur ned. I ndi cat e pr ocedur es f or compl i ance wi t h r egul at i ons gover ni ng di sposal of mer cur y. When such a ser vi ce i s not avai l abl e, seek l ocal r ecycl er s t o r ecl ai m t he mat er i al s.
1. 3. 2 Pr e- I nst al l at i on Meet i ngs
Wi t hi n 30 cal endar days af t er dat e of awar d , submi t f or t he appr oval of t he Cont r act i ng Of f i cer s i x ( 6) copi es of speci f i ed dr awi ngs of al l equi pment t o be f ur ni shed under t hi s cont r act , t oget her wi t h wei ght s and over al l di mensi ons. Submi t t he f ol l owi ng dat a and dr awi ngs:
a. Pol es
b. I nst al l at i on det ai l s
e. St eel pol es
h. Br acket s i . Anchor age syst ems
Af t er submi t t al s ar e r ecei ved and appr oved t he Cont r act i ng Of f i cer wi l l hol d a pr e- wor k conf er ence t o r evi ew t he f ol l owi ng:
a. The dr awi ngs, i ncl udi ng pol es, showi ng compl et e I nst al l at i on Det ai l s , and speci f i cat i ons. I ncl ude det ai l s f or t he f ol l owi ng f or r evi ew:
( 1) Foundat i on r equi r ement s ( 2) Anchor age syst ems ( 3) Manuf act ur er ' s cat al og dat a i ncl udi ng mount i ng and br acket det ai l s ( 4) Fact or y col or f i ni sh
b. Fi nal i ze const r uct i on schedul e and ver i f y avai l abi l i t y of mat er i al s, I nst al l er ' s per sonnel , equi pment , and f aci l i t i es needed t o make pr ogr ess and avoi d del ays.
c. Met hods and pr ocedur es r el at ed t o pol e and l umi nai r e i nst al l at i on, SECTI ON 26 56 13. 00 40 Page 3 i nc l udi ng manuf act ur er ' s wr i t t en i nst r uct i ons and ver i f i cat i on of pol e syst em assembl y wi nd l oad c l assi f i cat i on l i s t i ngs.
d. Gover ni ng r egul at i ons and r equi r ement s f or i nsur ance, cer t i f i cat es, t est s and i nspect i ons i f appl i cabl e. I ncl ude cer t i f i cat i on f or sust ai nabl e acqui s i t i on and pol e syst em assembl y wi nd l oad r at i ng c l assi f i cat i on. Saf et y pl an r evi ew i ncl udes appl i cabl e Saf et y Dat a Sheets.
e. Tempor ar y pr ot ect i on r equi r ement s f or pol e assembl y dur i ng and af t er installation.
f . Pol e syst em obser vat i on and r epai r pr ocedur es af t er compl et e i nst al l at i on. I ncl ude r evi ew of sampl e Al umi ni zed St eel Repai r Pai nt .
g. Sampl e War r ant y.
1. 4 SUBMITTALS
Gover nment appr oval i s r equi r ed f or submi t t al s wi t h a " G" desi gnat i on;
submi t t al s not havi ng a " G" desi gnat i on ar e f or Cont r act or Qual i t y Cont r ol appr oval . Submi t t al s wi t h an " S" ar e f or i ncl usi on i n t he Sust ai nabi l i t y eNot ebook, i n conf or mance t o Sect i on 01 33 29 SUSTAI NABI LI TY REPORTI NG.
Submi t t he f ol l owi ng i n accor dance wi t h Sect i on 01 33 00 SUBMI TTAL
PROCEDURES:
SD- 02 Shop Dr awi ngs
Pol es; G
I nst al l at i on Det ai l s ; G
SD- 03 Pr oduct Dat a
Local / Regi onal Mat er i al s; G
St eel Pol es; G
Br acket s; G
Anchor age Syst ems; G
SD- 05 Desi gn Dat a; G
Li ght i ng St andar ds; G
Soi l Test s; G
Sei smi c Desi gn Dat a; G
Manuf act ur er ' s Cat al og Dat a; G
Manuf act ur er ' s Col or Char t s and Chi ps; G
Saf et y Dat a Sheet s; G
SECTI ON 26 56 13. 00 40 Page 4
SD- 07 Cer t i f i cat es
Sust ai nabl e Acqui s i t i on; G
SD- 08 Manuf act ur er ' s I nst r uct i ons
Foundat i on Requi r ement s; G
Mount i ng Det ai l s ; G
SD- 10 Oper at i on and Mai nt enance Dat a
Oper at i onal Ser v i ce; G
SD- 11 Cl oseout Submi t t al s
War r ant y; G
Recor d Dr awi ngs; G
1. 5 QUALI TY CONTROL
1. 5. 1 Dr awi ng Requi r ement s
1. 5. 1. 1 Poles
I ncl ude di mensi ons, wi nd l oad det er mi ned i n accor dance wi t h AASHTO LTS, pol e def l ect i on, pol e c l ass, and ot her appl i cabl e i nf or mat i on conf or mi ng t o I ES HB- 10. Submi t soi l t est s t o t he Cont r act i ng Of f i cer pr i or t o t he commencement of wor k
1. 5. 2 Regul at or y Requi r ement s
I n each of t he publ i cat i ons r ef er r ed t o her ei n, consi der t he advi sor y pr ovi s i ons t o be mandat or y, f or " shoul d" wher ever i t appear s. I nt er pr et r ef er ences i n t hese publ i cat i ons t o t he " aut hor i t y havi ng j ur i sdi ct i on, " or wor ds of s i mi l ar meani ng, t o mean t he Cont r act i ng Of f i cer . Pr ovi de equi pment , mat er i al s, i nst al l at i on, and wor kmanshi p i n accor dance wi t h t he mandat or y and advi sor y pr ovi s i ons of NFPA 70 unl ess mor e st r i ngent r equi r ement s ar e speci f i ed or i ndi cat ed.
1. 5. 3 Al t er nat i ve Qual i f i cat i ons
Pr oduct s havi ng l ess t han a 2- year f i el d ser vi ce r ecor d wi l l be accept abl e i f a cer t i f i ed r ecor d of sat i sf act or y f i el d oper at i on f or not l ess t han 6000 hour s, excl usi ve of t he manuf act ur er s ' f act or y or l abor at or y t est s, i s furnished.
1. 5. 3. 1 Mat er i al and Equi pment Manuf act ur i ng Dat e
Pr oduct s manuf act ur ed mor e t han 3 year s pr i or t o dat e of del i ver y t o s i t e ar e not al l owed, unl ess speci f i ed ot her wi se.
1. 5. 4 Manuf act ur er ' s Col or Char t s and Chi ps
Submi t manuf act ur er ' s col or char t s and chi ps, appr oxi mat el y 4 by 4 i nches, showi ng f ul l r ange of col or s, t ext ur es and pat t er ns avai l abl e f or al umi num pol es wi t h f act or y appl i ed f i ni shes.
SECTI ON 26 56 13. 00 40 Page 5
1. 6 DELI VERY, STORAGE, AND HANDLI NG
Del i ver , st or e, and handl e pol es, and al l r el at ed accessor i es and ot her manuf act ur ed i t ems i n a manner t o pr event damage or def or mat i on.
1. 6. 1 St eel Pol es
Do not st or e pol es on gr ound. Suppor t pol es so t hey ar e at l east one f oot above gr ound l evel and gr owi ng veget at i on. Do not r emove f act or y- appl i ed pol e wr appi ngs unt i l j ust bef or e i nst al l i ng pol e.
1. 7 WARRANTY
Pr ovi de suppor t f or t he equi pment i t ems by ser vi ce or gani zat i ons whi ch ar e r easonabl y conveni ent t o t he equi pment i nst al l at i on i n or der t o r ender sat i sf act or y ser vi ce t o t he equi pment on a r egul ar and emer gency basi s dur i ng t he war r ant y per i od of t he cont r act .
PART 2 PRODUCTS
2. 1 SYSTEM DESCRI PTI ON
Pr ovi de mat er i al s and equi pment t hat ar e pr oduct s of manuf act ur er s r egul ar l y engaged i n t he pr oduct i on of such pr oduct s whi ch ar e of equal mat er i al , desi gn and wor kmanshi p, whi ch have been i n sat i sf act or y commer ci al or i ndust r i al use f or 2 year s pr i or t o bi d openi ng under s i mi l ar c i r cumst ances and of s i mi l ar s i ze, and have been on sal e on t he commer ci al mar ket t hr ough adver t i sement s, manuf act ur er s ' cat al ogs, or br ochur es dur i ng t he 2- year per i od.