SSC_-_SS-1-5_-_Product_Report.pdf

PDF 34 KB Posted

Attached to
Computer Room HVAC Upgrade
Solicitation number
Quote- 26 - 205
Issued by
Pinellas County, Florida

About this file

This file contains a product specification report and a related state and local contract opportunity for the City of St. Petersburg, Florida, regarding HVAC system upgrades. The City is requesting quotes from qualified vendors for the installation of a conventional split-style air conditioning system sized for 3.5 tons to replace an existing 5-ton Libert unit in a computer room application. The project, identified as "COSP - City Hall HVAC Renovations," requires installation of a new outdoor condenser unit, indoor air handler unit, and associated refrigerant piping, with the vendor responsible for uninstallation and disposal of the existing equipment. Additionally, a standalone humidifier system with a capacity of 5 pounds per hour must be installed separately, as conventional split-style AC units lack humidifier capability. The specification document provided details a 1.5-5 ton unitary split system unit (model SS-1-5) with cooling capacity of 39,000 Btuh at AHRI rating and 35,873 Btuh net cooling capacity, featuring R-454B refrigerant and a SEER2 rating of 14.30.

This is a sheltered bid contract opportunity, which requires that at least 20 percent of the contracting effort, including the cost of supplies, be self-performed by the SBE (Small Business Enterprise) prime contractor. No specific response deadline, due date, site visit requirements, bidder's conference, or award date is provided in the available documentation. The contract pricing terms, funding sources, total contract value, and term length are not specified in the materials reviewed. The project location is the City of St. Petersburg, Florida.

View the file

Other files

File Type Posted
Computer_Room_HVAC_Upgrade.pdf PDF
1937.08_City_Hall_Computer_Room_HVAC_Drawings.pdf PDF
Subcontractor_Summary_Spreadsheet.xlsx XLSX spreadsheet
SSC_-_SS-1-5_-_As_Built_Drawings.pdf PDF
Light_Construction_Agreement.docx DOCX document
Public_Construction_Bond.docx DOCX document
1937.08_City_Hall_-_Computer_Room_HVAC_-_Drawings_100%_CD's_Review.pdf PDF
Subcontractor_Summary_-_Sheltered_.xlsx XLSX spreadsheet
Quote_Addendum.docx DOCX document
Subcontractor_Utilization_Plan.docx DOCX document
Performance_&_Payment_Bond_.DOCX DOCX document
Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1.5 - 5 Ton Unitary Split System Unit Overview

System Type A/C with Air Handler Outdoor Unit Model 1.5-5 Ton Split Sys Clg R-454B

Outdoor Unit Nominal Capacity 042 Indoor Unit Model

Indoor Unit Nominal Capacity 36 - 48K Cooling Capacity

AHRI Data AHRI Reference Number 215440465

Airflow @ AHRI 1155 cfm Capacity @ AHRI 39000.00 Btuh

EER2 @ AHRI 12

SEER2 @ AHRI 14.30

Unit Electrical Outdoor Unit 5TTR4042A1

Power Supply 200-230/60/1 Indoor Unit 5TEM4D05AC41

Power Supply 208- 230/60/1

Cooling Performance Cooling Airflow 1375 cfm

Cooling EDB 72.00 F Cooling EWB 59.00 F

Cooling Outdoor Temp. 95.00 F

Net Cooling Capacity 35873.00 Btuh Net Sensible Capacity 29370.00 Btuh

Net Latent Capacity 6503.00 Btuh Cooling LDB 52.20 F Cooling LWB 49.10 F

Job Name: COSP - City Hall HVAC Renovations Prepared For:

Unit Tag: SS-1-5 Quantity: 1

2026/04/08 10:27:40 Page 1 of 1