SOW Attachment 8 _ DC0022 IRS Building Annual Asbestos Inspection _ Survey Report-FINAL.pdf
PDF 3 MB Posted
- Solicitation number
- 47PB5126R0029
- Issued by
- Not on record
About this file
This is an Annual Asbestos Operations and Maintenance Inspection Report for the IRS Building (DC0022) located at 1111 Constitution Avenue NW in Washington, DC, prepared by Mabbett & Associates, Inc. for the General Services Administration (GSA) National Capital Region Safety, Environmental, and Fire Protection Branch.
The inspection was conducted December 8-10, 2015 by Industrial Hygienists Andrew Faust and Rudolph Scipio in accordance with GSA and EPA Asbestos Hazard and Emergency Response Act (AHERA) protocols. The visual inspection of previously identified asbestos-containing building materials (ACBM) revealed seventeen homogenous areas in good condition. During the inspection, 42 samples of suspect ACBM were collected and analyzed by Scientific Analytical Institute Inc. using polarized light microscopy (PLM), with four materials found to contain asbestos: black tar flooring (5% chrysotile) in air shaft rooms throughout (12,000 SF with 5,000 SF damaged); 4" O.D. white fibrous pipe insulation with minor damage in Room 2560 (200 LF with 4 LF damaged, 20% chrysotile); fire door insulation throughout (60 EA, 18% chrysotile and 2% amosite); and red duct sealant in Room A611 (50 LF, 3% chrysotile). The total estimated abatement cost for all identified ACBM in the building is $4,184,183 based on 2015 RS Means unit rates with locality adjustments. The report recommends removing, enclosing, encapsulating, or repairing any currently damaged ACBM and continuing periodic inspections per AHERA guidelines. Some areas remained inaccessible due to security restrictions and were not included in liability estimates.
View the file
Other files
Show all 24
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
© 2016, Mabbett & Associates, Inc. S:\ADMINA\2012011 GSA NCR\ACM OM 2015-2016 120\DC0022 IRS Building Annual Asbestos Inspection & Survey Report-FINAL.doc
A US Department of Veterans Affairs Verified Service-Disabled Veteran-Owned Small Business Scientists | Engineers | Program Managers
Mabbett & Associates, Inc.
1442 Duke Street Alexandria, VA 22314 Tel: (703) 997-6051 info@mabbett.com www.mabbett.com
June 30, 2016
Mr. Sam Schrecongost Environmental Protection Specialist General Services Administration (GSA) Safety, Environment, & Fire Protection Branch 7th & D Streets, SW, Room 2080 Washington, DC 20407
Subject: Annual Asbestos Operations and Maintenance Inspection Report IRS Building (DC0022) Contract No.: GS-11P-12-DC-C-007Mabbett Order No.: GS-P-11-15-DC-5008 Mabbett Project No.: 2012011.120
Dear Mr. Sam Schrecongost:
Mabbett & Associates, Inc. (Mabbett®) received a Task Order request from GSA National Capital Region (NCR) Safety, Environmental, and Fire Protection Branch to conduct annual asbestos operations and maintenance (O&M) inspections for 90 GSA NCR facilities. This report summarizes the results of the inspection conducted at the IRS Building (DC0022) located at 1111 Constitution Avenue NW in Washington D.C.
The inspection was conducted between December 8, 2015 and December 10, 2015 by Mabbett Industrial Hygienists Andrew Faust and Rudolph Scipio. The inspection and sampling were performed in accordance with GSA and U.S. Environmental Protection Agency (USEPA) Asbestos Hazard and Emergency Response Act (AHERA) protocols.
Methods
Sampling documentation previously conducted in the 1111 Constitution building was provided by GSA prior to the December 2015 inspection. The locations of the previously identified asbestos-containing building materials (ACBM) were visually inspected to determine if the ACBM was still present, the estimated quantity of each material remaining, and the current condition of the materials assessed. A visual inspection of accessible portions of the main building was also conducted to identify and sample suspect materials that were not previously identified as potential ACBM or previously confirmed to be non-ACBM.
Samples collected of suspect ACBM identified during this inspection were documented on sample forms and chain-of-custody and shipped to Scientific Analytical Institute Inc. (SAI) of Greensboro, Mr. Sam Schrecongost June 30, 2016
© 2016, Mabbett & Associates, Inc. S:\ADMINA\2012011 GSA NCR\ACM OM 2015-2016 120\DC0022 IRS Building Annual Asbestos Inspection & Survey Report-FINAL.doc
A US Department of Veterans Affairs Verified Service-Disabled Veteran-Owned Small Business Scientists | Engineers | Program Managers
North Carolina. The bulk samples were analyzed for asbestos content by polarized light microscopy (PLM). SAI is accredited by the American Industrial Hygiene Association (AIHA) and participates in the National Voluntary Laboratory Accreditation Program (NVLAP) for bulk asbestos fiber analysis.
Upon completion of the survey and receipt of laboratory results, the estimated quantities of asbestos containing materials were entered into the O&M Inventory and Surveillance Report Form Table.
Included on the Table is the estimated cost for abatement of the known ACBM to support liability estimate reporting. This liability cost provided was based on a unit cost for the removal of the known materials using current version of RS Means with locality cost adjustments, general condition, and contingency factors. It should be noted that equipment, ACBM disposal, and third party air monitoring costs were not included in the liability cost totals.
Findings
The visual inspection of the previously identified ACBM in the IRS Building revealed seventeen (17) homogenous areas i n good condition. During this inspection, forty-two (42) samples of suspect ACBM were collected and analyzed, with four (4) of these new materials found to contain asbestos. These four (4) materials consisted of black tar flooring; 4” O.D. (outside diameter) white fibrous pipe insulation with minor damage; fire door insulation; and red duct sealant. The specific descriptions, locations and condition of the ACBM inspected and newly inventoried ACBMs are included in the O&M Inventory and Surveillance Report Form in Attachment A. The Asbestos Assessment Data Forms are contained in Attachment B.
Detailed sample information is found in the Laboratory Analysis Report in Attachment C. Photographs of the newly sampled ACBM are included in Attachment D. A listing of newly sampled materials that were found not to contain asbestos is included in Attachment E.
Some areas were inaccessible during this inspection due to security restrictions. Inaccessible suspect materials not previously sampled should be assumed to contain asbestos but are not included in the liability estimates. All square and linear footage measurements are estimates only.
Conclusions & Recommendations
Consider removing, enclosing, encapsulating or repairing any ACBM that is currently damaged or may become damaged. Continue to periodically inspect existing ACBM in accordance with AHERA guidelines.
As newly identified materials are identified or materials are abated, the liabilities estimates in this report should be revised accordingly.
Mr. Sam Schrecongost
© 2016, Mabbett & Associates, Inc. S:\ADMINA\2012011 GSA NCR\ACM OM 2015-2016 120\DC0022 IRS Building Annual Asbestos Inspection & Survey Report-FINAL.doc
A US Department of Veterans Affairs Verified Service-Disabled Veteran-Owned Small Business Scientists | Engineers | Program Managers
Mabbett appreciates this opportunity to provide these asbestos consulting services for GSA-NCR.
Should you have any questions or concerns, please do not hesitate to contact us at (703) 997-6051.
Very truly yours, MABBETT & ASSOCIATES, INC.
By:
Andrew Faust Industrial Hygienist/Environmental Specialist
Reviewed by:
David A. Nelson, RPIH Senior Industrial Hygienist/Environmental Consultant
Gary Morris, CIH, CSP Senior Industrial Hygienist
Attachment A: Asbestos Inventory and Periodic Surveillance Assessment Report Attachment B: Asbestos Assessment Data Forms Attachment C: Laboratory Analysis Results and Chain-of-Custody Form Attachment D: Representative Newly Identified Asbestos Containing Building Material
Photographs Asbestos Containing Building Material Photos Attachment E: Sampled Non-Asbestos Containing Building Materials List
Annual Asbestos Operations & Maintenance Inspection Report IRS Building (DC0022)
June 30, 2016
© 2016, Mabbett & Associates, Inc. DC0022 IRS Building Annual Asbestos Inspection & Survey Report-FINAL Project No. 2012011.120 Attachment A
A US Department of Veterans Affairs Verified Service-Disabled Veteran-Owned Small Business Scientists | Engineers | Program Managers
ATTACHMENT A
Asbestos Inventory and Periodic Surveillance Assessment Report
© 2016, Mabbett Associates, Inc.
REVISED 5/31/2016
INSPECTOR: Mabbett AF RS ASBESTOS PROGRAM MANAGER: Samuel Schrecongost
LOCATION(S) OF IDENTIFIED ACBM
FLOOR/ROOM HOMOGENEOUS MATERIAL
NEWLY IDENTIFIED
DURING THIS
INSPECTION/SAMPLE #
EST.
QUANTITY OF
ACBM UNITS
FRIABLE
YES/NO CONDITION1 AVAILABLE RESULTS
EST. QUANTITY OF
DAMAGE (S.F./L.F.)
RECOMMENDED
RESPONSE ACTION(S)3
EST. ABATEMENT
COST (USD 2015)
Throughout Fire door insulation Yes / IRS-12915-14,15 60 EA No Good 18% chrysotile, 2% Amosite N/A O&M $1,317 Air shaft rooms throughout Black tar flooring Yes / IRS-12815-12,13,14 12,000 S.F. No Minor damage 5% chyrsotile 5,000 S.F. Repair / O&M $33,346
Room 2560 Interstitial Space 4" white fibrous insulation Yes / IRS-12915-11,12,13 200 L.F. No Minor damage 20% chrysotile 4 L.F. Repair / O&M $1,672 A611 Red duct sealant Yes / IRS-12815-08,09 50 L.F Yes Good 3% chrysotile N/A O&M $329
Throughout Black adhesive on fiberglass duct No 40,000 S.F. No Good 15% chrysotile N/A O&M $263,130 Stairwell 53 - behind radiators Gray corrugated asbestos paper No 42 S.F. Yes Good 40% chrysotile N/A O&M $351
Attic Canvas wrapped AHU Duct Insulation No 48,000 S.F. Yes Good 25% chrysotile, 25% amosite N/A O&M $401,335 Attic - AHU4 Mudded patching on AHU Duct No 1 S.F. No Good 40% chrysotile N/A O&M $22
Throughout offices - under floor tile and carpet Black mastic associated with 9X9 Floor Tile No 673,230 S.F. No Good Assumed N/A O&M Inculded in Floor tile Throughout offices - under carpet 9"x9" floor tile (all colors/patterns) No 673,230 S.F. No Good 2% chrysotile N/A O&M $1,870,806
Attic Off white mudded joints No 5,670 EA Yes Good 25% chrysotile N/A O&M $124,445 Attic Gray mudded joints No 1,120 EA Yes Good 20% chrysotile N/A O&M $24,582
Library Gray mudded joints No 3 EA Yes Good 90% chrysotile N/A O&M $66 Attic Brown/white pipe hanger No 990 EA Yes Good 10% chrysotile, 25% amosite N/A O&M $21,729 Attic Gray pipe hanger No 930 EA Yes Good 8% chrysotile, 20% amosite N/A O&M $20,412
Attic and risers in walls throughout White mag insulation No 16,600 L.F. Yes Good 45% chrysotile N/A O&M $138,795 Room G330 Gray mudded insulation in wall penetration No 150 L.F. Yes Good 40% chrysotile N/A O&M $1,254
Attic White mag insulation No 136,000 L.F. Yes Good 30% amosite N/A O&M $1,137,116 Attic Gray/white fibrous pipe insulation No 8,200 L.F. Yes Good 40% amosite N/A O&M $68,561 Attic White fibrous insulation with metal jackets No 6,300 L.F. Yes Good 35% amosite N/A O&M $52,675
Attic White fibrous insulation on hot water lines No 2,660 L.F. Yes Good 20% chrysotile, 30% amosite, 5% crocidolite N/A O&M $22,241
1 GOOD, DAMAGED OR SIGNIFICANTLY DAMAGED BUILDING TOTAL $4,184,183
2 AIR EROSION, VANDALISM, VIBRATION, WATER, ETC.
3 REPAIR, REMOVE, ENCAPSULATE, ENCLOSE, OR O&M
EA-Each S.F.-Square Feet -L.F.-Linear Feet
RS Means Basis of Abatement Cost Estimates Cost per Unit Locality Adjustment
General Conditions Adjustment
Contingency Adjustment
Total Estimated Unit Price
Flooring $2.26 0.972 1.15 1.1 2.78$ Pipe Insulation $6.80 0.972 1.15 1.1 8.36$
Pipe Fittings $17.85 0.972 1.15 1.1 21.95$ Caulking $5.35 0.972 1.15 1.1 6.58$
Ceiling Tile/Wall Board $1.46 0.972 1.15 1.1 1.80$ Thermal Insulation $11.40 0.972 1.15 1.1 14.02$
Notes: Miscellaneous materials identified which do not fall into one of the categories above are not included in the liability estimate due to the high variability of cost and the lack of proper RS Means estimations. The estimated abatement unit costs provided above are based on current industry unit rate estimates and are intended to be inclusive of all abatement contractor costs. They do not include costs for waste disposal, design, monitoring, sampling, and other consultant fees.
Attachment A - Asbestos Inventory and Periodic Surveillance Assessment Report
GSA BUILDING NUMBER: DC0022
DATE OF INSPECTION: 12/8/2015/-12/10/2015
DATE SUBMITTED TO WPMACB:
BUILDING NAME: IRS Building BUILDING ADDRESS: 1111 Constitution Avenue
Annual Asbestos Operations & Maintenance Inspection Report IRS Building (DC0022)
June 30, 2016
© 2016, Mabbett & Associates, Inc. DC0022 IRS Building Annual Asbestos Inspection & Survey Report-FINAL Project No. 2012011.120 Attachment B
A US Department of Veterans Affairs Verified Service-Disabled Veteran-Owned Small Business Scientists | Engineers | Program Managers
ATTACHMENT B
Asbestos Assessment Data Form
June 30, 2016
© 2016, Mabbett & Associates, Inc. DC0022 IRS Building Annual Asbestos Inspection & Survey Report-FINAL Project No. 2012011.120 Attachment C
A US Department of Veterans Affairs Verified Service-Disabled Veteran-Owned Small Business Scientists | Engineers | Program Managers
ATTACHMENT C
Laboratory Analysis Results and Chain-of-Custody Forms
Bulk Asbestos Analysis By Polarized Light Microscopy
EPA Method: 600/R-93/116 and 600/M4-82-020
LAB #173190
2015 O&M - IRS BuildingProject:
Sample ID
Lab Sample ID
Description
Lab Notes Asbestos Fibrous
Components Non-Fibrous Components
Attributes
Treatment
David NelsonAttn:Customer: Mabbett & Associates 1442 Duke St Alexandria VA 22314
Analysis ID: 1524299_PLM
Date Reported: 12/15/2015
Date Received: 12/15/2015
Lab Order ID: 1524299
None Detected
IRS-12815-
Gray fireproofing Gray Fibrous Heterogeneous
Teased1524299PLM_1
Fiber Glass Cellulose
Other 90% 5%
5%
None Detected
IRS-12815-
Gray fireproofing Gray Fibrous Heterogeneous
Teased1524299PLM_2
Fiber Glass Cellulose
Other 90% 5%
5%
None Detected
IRS-12815-
Gray fireproofing Gray Fibrous Heterogeneous
Teased1524299PLM_3
Fiber Glass Cellulose
Other 90% 5%
5%
None Detected
IRS-12815-
Gray fireproofing Gray Fibrous Heterogeneous
Teased1524299PLM_4
Fiber Glass Cellulose
Other 90% 5%
5%
None Detected
IRS-12815-
Gray fireproofing Gray Fibrous Heterogeneous
Teased1524299PLM_5
Fiber Glass Cellulose
Other 90% 5%
5%
None Detected
IRS-12815-
Gray fireproofing Gray Fibrous Heterogeneous
Teased1524299PLM_6
Fiber Glass Cellulose
Other 90% 5%
5%
None Detected
IRS-12815-
Gray fireproofing Gray Fibrous Heterogeneous
Teased1524299PLM_7
Fiber Glass Cellulose
Other 90% 5%
5%
3% Chrysotile
IRS-12815-
Red duct sealant Red Non Fibrous Homogeneous
Ashed1524299PLM_8
Other 97%
Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program. Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.
Approved SignatoryAnalyst
Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
Bobby Wheatley (42)
P-F-002 r15 1/15/2018
EPA Method: 600/R-93/116 and 600/M4-82-020
LAB #173190
2015 O&M - IRS BuildingProject:
Sample ID
Lab Sample ID
Description
Lab Notes Asbestos Fibrous
Components Non-Fibrous Components
Attributes
Treatment
David NelsonAttn:Customer: Mabbett & Associates 1442 Duke St Alexandria VA 22314
Analysis ID: 1524299_PLM
Date Reported: 12/15/2015
Date Received: 12/15/2015
Lab Order ID: 1524299
3% Chrysotile
IRS-12815-
Red duct sealant Red Non Fibrous Homogeneous
Ashed1524299PLM_9
Other 97%
None Detected
IRS-12815-
Black tar paper on fiberglass sheet vinyl only
Black, Tan Fibrous Heterogeneous
Teased, Dissolved1524299PLM_10
Cellulose Other 80% 20%
None Detected
IRS-12815-
Black tar paper on fiberglass sheet vinyl only
Black, Tan Fibrous Heterogeneous
Teased, Dissolved1524299PLM_11
Cellulose Other 80% 20%
5% Chrysotile
IRS-12815-
Black tar roofing Black Non Fibrous Heterogeneous
Dissolved1524299PLM_12
Other 95%
5% Chrysotile
IRS-12815-
Black tar roofing Black Non Fibrous Heterogeneous
Dissolved1524299PLM_13
Other 95%
5% Chrysotile
IRS-12815-
Black tar roofing Black Non Fibrous Heterogeneous
Dissolved1524299PLM_14
Other 95%
None Detected
IRS-12915-
Red fire stop Red Non Fibrous Heterogeneous
Ashed1524299PLM_15
Fiber Glass Other 3% 97%
None Detected
IRS-12915-
Red fire stop Red Non Fibrous Heterogeneous
Ashed1524299PLM_16
Fiber Glass Other 3% 97%
Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program. Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.
Approved SignatoryAnalyst
Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
EPA Method: 600/R-93/116 and 600/M4-82-020
LAB #173190
2015 O&M - IRS BuildingProject:
Sample ID
Lab Sample ID
Description
Lab Notes Asbestos Fibrous
Components Non-Fibrous Components
Attributes
Treatment
David NelsonAttn:Customer: Mabbett & Associates 1442 Duke St Alexandria VA 22314
Analysis ID: 1524299_PLM
Date Reported: 12/15/2015
Date Received: 12/15/2015
Lab Order ID: 1524299
None Detected
IRS-12915-
Gray fire proofing Gray Fibrous Heterogeneous
Teased1524299PLM_17
Fiber Glass Other 95% 5%
None Detected
IRS-12915-
Gray fire proofing Gray Fibrous Heterogeneous
Teased1524299PLM_18
Fiber Glass Other 95% 5%
None Detected
IRS-12915-
Gray fire proofing Gray Fibrous Heterogeneous
Teased1524299PLM_19
Fiber Glass Other 95% 5%
None Detected
IRS-12915-
Cementitious 1'x1' wall tile Gray Fibrous Heterogeneous
Teased1524299PLM_20
Fiber Glass Other 95% 5%
None Detected
IRS-12915-
Cementitious 1'x1' wall tile Gray Fibrous Heterogeneous
Teased1524299PLM_21
Fiber Glass Other 95% 5%
None Detected
IRS-12915-
Cementitious 1'x1' wall tile Gray Fibrous Heterogeneous
Teased1524299PLM_22
Fiber Glass Other 95% 5%
None Detected
IRS-12915-
Brown sheet vinyl sheet vinyl only
Brown Fibrous Heterogeneous
Teased, Dissolved1524299PLM_23
Cellulose Other 40% 60%
None Detected
IRS-12915-
Brown sheet vinyl sheet vinyl only
Brown Fibrous Heterogeneous
Teased, Dissolved1524299PLM_24
Cellulose Other 40% 60%
Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program. Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.
Approved SignatoryAnalyst
Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
EPA Method: 600/R-93/116 and 600/M4-82-020
LAB #173190
2015 O&M - IRS BuildingProject:
Sample ID
Lab Sample ID
Description
Lab Notes Asbestos Fibrous
Components Non-Fibrous Components
Attributes
Treatment
David NelsonAttn:Customer: Mabbett & Associates 1442 Duke St Alexandria VA 22314
Analysis ID: 1524299_PLM
Date Reported: 12/15/2015
Date Received: 12/15/2015
Lab Order ID: 1524299
20% Chrysotile
IRS-12915-
4" mag insulation White Fibrous Heterogeneous
Teased1524299PLM_25
Other 80%
20% Chrysotile
IRS-12915-
4" mag insulation White Fibrous Heterogeneous
Teased1524299PLM_26
Other 80%
20% Chrysotile
IRS-12915-
4" mag insulation White Fibrous Heterogeneous
Teased1524299PLM_27
Other 80%
18% Chrysotile 2% Amosite
IRS-12915-
Fire door insulation White Fibrous Heterogeneous
Teased1524299PLM_28
Other 80%
18% Chrysotile 2% Amosite
IRS-12915-
Fire door insulation White Fibrous Heterogeneous
Teased1524299PLM_29
Other 80%
None Detected
IRS-121015-
Pink fire stop Pink Non Fibrous Heterogeneous
Crushed1524299PLM_30
Other 100%
None Detected
IRS-121015-
Pink fire stop Pink Non Fibrous Heterogeneous
Crushed1524299PLM_31
Other 100%
None Detected
IRS-121015-
Plaster patch single layer plaster
Gray Non Fibrous Heterogeneous
Crushed1524299PLM_32
Other 100%
Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program. Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.
Approved SignatoryAnalyst
Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
EPA Method: 600/R-93/116 and 600/M4-82-020
LAB #173190
2015 O&M - IRS BuildingProject:
Sample ID
Lab Sample ID
Description
Lab Notes Asbestos Fibrous
Components Non-Fibrous Components
Attributes
Treatment
David NelsonAttn:Customer: Mabbett & Associates 1442 Duke St Alexandria VA 22314
Analysis ID: 1524299_PLM
Date Reported: 12/15/2015
Date Received: 12/15/2015
Lab Order ID: 1524299
None Detected
IRS-121015-
Plaster patch single layer plaster
Gray Non Fibrous Heterogeneous
Crushed1524299PLM_33
Other 100%
None Detected
IRS-121015-
Plaster patch single layer plaster
Gray Non Fibrous Heterogeneous
Crushed1524299PLM_34
Other 100%
None Detected
IRS-121015-
1'x2' wall tile Gray Fibrous Heterogeneous
Teased1524299PLM_35
Fiber Glass Other 80% 20%
None Detected
IRS-121015-
1'x2' wall tile Gray Fibrous Heterogeneous
Teased1524299PLM_36
Fiber Glass Other 80% 20%
None Detected
IRS-121015-
Adhesive Brown Non Fibrous Homogeneous
Dissolved1524299PLM_37
Other 100%
None Detected
IRS-121015-
Adhesive Brown Non Fibrous Homogeneous
Dissolved1524299PLM_38
Other 100%
None Detected
IRS-121015-
1'x1' wall tile White, Yellow Fibrous Heterogeneous
Teased, Dissolved1524299PLM_39
Fiber Glass Cellulose
Other 75% 5%
20%
None Detected
IRS-121015-
1'x1' wall tile White, Yellow Fibrous Heterogeneous
Teased, Dissolved1524299PLM_40
Fiber Glass Cellulose
Other 75% 5%
20%
Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program. Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.
Approved SignatoryAnalyst
Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
EPA Method: 600/R-93/116 and 600/M4-82-020
LAB #173190
2015 O&M - IRS BuildingProject:
Sample ID
Lab Sample ID
Description
Lab Notes Asbestos Fibrous
Components Non-Fibrous Components
Attributes
Treatment
David NelsonAttn:Customer: Mabbett & Associates 1442 Duke St Alexandria VA 22314
Analysis ID: 1524299_PLM
Date Reported: 12/15/2015
Date Received: 12/15/2015
Lab Order ID: 1524299
None Detected
IRS-121015-
Adhesive Brown Non Fibrous Homogeneous
Dissolved1524299PLM_41
Other 100%
None Detected
IRS-121015-
Adhesive Brown Non Fibrous Homogeneous
Dissolved1524299PLM_42
Other 100%
Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program. Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.
Approved SignatoryAnalyst
Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
Scientific Analytical Institute 4604 Dundas Dr. Greensboro, NC 27407
Phone: 336•.292.3888 Fax:336.292.3313 www.sallab.comlab@sailab.com
~:t~d~;~: 16BY)99
Client Code: ______
Company: Mabbett & Associates
Address: 1442 Duke Street Phone : (703) 963-5540
Alexandria, VA Fax 0:
22314 Email 0:Dne1son@mabbett.com
.~.I:~~~_~99~:?~{!!?-<'~~ML ___ ...
6 Hours 96 Hours 0Address: 5 Alfred Circle
Bedford, MA 12 Hours 120Hours 0 01730 24 Hours 144"'Hours 0
Company: Mabbett & Associates 90 Min. 48 Hours
Contact: Kathleen Davis 3 Hours 72 Hours
PO Number: 2012011.120
Project NameINumber: 2015 O&M - IRS Building
Positive stop o nM Point Count 400 (PT4) 0 PLM Point Count 1000 (PTM) 0 PCM mOSH 74O(l-~Rules (PCM) 0 B Rules (PCB) 0 TWA (PTA) 0
TEM AHERA (ABE) 0
TEM Level II(U1) 0 TEM mOSH 7402 (TNI) 0 TEM Bulk Qualitative (TBL) 0 TEM Bulk Chatfield (lBS) 0 TEM Bulk Quantitative (TBQ) 0 TEM Wipe ASTM 06480-05 0 TEM Microvac ASTM D5755-02 0 TEMWaterEPA 100.2 (TWl) 0 Other:
IRS-1281S-02
IRS-1281S-03
IRS-1281S-04
IRS-12815-0S
IRS-1281S-06
IRS-1281S-07
IRS-1281S-08 Red Duct Sealant
RS-1281S-09
lRS-1281S-10 Black tar paper on fiberglass
IR5-1281S-11
Total # ofSamp1es __
Page__of__
A-F-017 EXP; 12-1-13
mailto:www.sallab.comlab@sailab.com
I
Scientific Analytical Institute 4604 Dundas Dr. Greensboro, NC 27407
Phone: 336.292.3888 Fa
Lab Use Only Lab Order ill: ______
·3B.t~~...~loh1af-----www.sailab.comlab@Sailab.com
, ... ",.~.•. 2~. ]D~~c,:·I'··""""'·;ft!_? ..~;.~J··· 'ts. '. ;1";': :.;:;;.... . ;. ,., IRS-1281S-12 Black tar flooring
IRS-1281S-13 1
IRS-1281S-14
IRS-1291S-01 "'"Red fire stop
IRS-1291S-02 ...v IRS-1291S-03 IGray fire proofing
IRS-1291S-04 I
IRS-1291S-QS ~
lRS-1291S-Q6 Cementitious l'xl' Wall Tile
IRS-1291S-07 I
IRS-1291S-08 'V'
IRS-1291S-09 Brown sheet vinyl
IRS-1291S-10 ¥
IRS-1291S-11 4" mag insulation
IRS-1291S-12 I
IRS-1291S~13 W
IRS-1291S-14 Fire door insulation
IRS-1291S-1S .J.,
IRS-121D1S-Dl Pink fire stop
IRS-12101S-02 ~
IRS-12101S-03
IRS-12101S-04
IRS-12101S-QS
IRS-12101S-Q6
I RS-12101S-07
I RS-12101S-08
IRS-12101S-09
I RS-12101S-10
IRS-12101S-11
IRS-12101S-12
iIRS-12101S-13
Plaster patch
I l'x2' wall tile
J/ IAdhesive
Jt. .' l'xl' waif tile
Adhesive
I
I
I
I mailto:www.sailab.comlab@Sailab.com
June 30, 2016
© 2016, Mabbett & Associates, Inc. DC0022 IRS Building Annual Asbestos Inspection & Survey Report-FINAL Project No. 2012011.120 Attachment D
A US Department of Veterans Affairs Verified Service-Disabled Veteran-Owned Small Business Scientists | Engineers | Program Managers
ATTACHMENT D
Representative Newly Identified Asbestos Containing Building Material Photographs
Photo #1: White Fibrous 4” Pipe Interstitial Space (Sample # IRS-12915-11,12&13)
IRS Building (DC0022)
June 30, 2016
© 2016, Mabbett & Associates, Inc.
Project No. 2012011.120
DC0022 IRS Building Annual Asbestos Inspection & Survey Report-FINAL Attachment D
Photo #2: Black Tar Flooring (Sample # IRS-12815-12,13&14)
IRS Building (DC0022)
June 30, 2016
© 2016, Mabbett & Associates, Inc.
Project No. 2012011.120
DC0022 IRS Building Annual Asbestos Inspection & Survey Report-FINAL
Photo #3: Fire Door Core Insulation (Sample # IRS-12915-14&15)
IRS Building (DC0022)
June 30, 2016
© 2016, Mabbett & Associates, Inc.
Project No. 2012011.120
DC0022 IRS Building Annual Asbestos Inspection & Survey Report-FINAL
Photo #4: Red Duct Sealant (Sample # IRS-12815-08&09)
IRS Building (DC0022)
June 30, 2016
© 2016, Mabbett & Associates, Inc.
Project No. 2012011.120
DC0022 IRS Building Annual Asbestos Inspection & Survey Report-FINAL
June 30, 2016
© 2016, Mabbett & Associates, Inc. DC0022 IRS Building Annual Asbestos Inspection & Survey Report-FINAL Project No. 2012011.120 Attachment E
A US Department of Veterans Affairs Verified Service-Disabled Veteran-Owned Small Business Scientists | Engineers | Program Managers
ATTACHMENT E
Newly Sampled Non-Asbestos Containing Building Materials List
© 2016, Mabbett Associates, Inc. Page 1 of 1
Material Sample Location Sample Number Color Results Sample Date
Fire proofing Attic - Annex Façade IRS-12815-01,02,03,04,05,06,07 Gray None Detected 12/8/2015
Tar Paper on fiberglass Room A410 IRS-12815-10,11 Black None Detected 12/8/2015
Red Fire stop Mechanical space penetrations IRS-12915-01,02 Red None Detected 12/9/2015
Fire proofing Exposed beams in basement to 7th floor near 700 corridor IRS-12915-03,04,05 Gray None Detected 12/9/2015
Cementitious 1'x1' wall tile Room 3208 IRS-12915-06,07,08 White None Detected 12/9/2015
Brown Sheet vinyl flooring Room 3208 IRS-12915-09,10 Brown None Detected 12/9/2015
Pink Fire stop 1st floor wire closet by stairwell 41 IRS-121015-01,02 Pink None Detected 12/10/2015
Plaster patch Room 1021 IRS-121015-03,04,05 White None Detected 12/10/2015
1'x2' Wall tile Room 1017 IRS-121015-06,07 White None Detected 12/10/2015
Wall Tile adhesive Room 1017 IRS-121015-08,09 Yellow None Detected 12/10/2015
1'x1' Wall tile Room 1017 IRS-121015-10,11 White None Detected 12/10/2015 Wall Tile adhesive Room 1017 IRS-121015-12,13 Yellow None Detected 12/10/2015
Attachment E - Newly Sampled Non-Asbestos Containing Building Materials List IRS Building
Annual Asbestos Operations & Maintenance Inspection Report IRS Building (DC0022)
| Copy of OM INVENTORY_SURVEILLANCE REPORT FORM - IRS Building.pdf |
| Asbestos Inventory |
| Copy of Sampled Non ACM Materials List - IRS Building.pdf |
| Sheet1 |
File details come from the government source that posted it. Updated .