SO-1853 EBERSOLE - BID PACK 2 - BIDS AND PERMITS.pdf
PDF 8 MB Posted
- Attached to
- School Kitchen Renovations
- Solicitation number
- RFP LSD 260000001562 3
- Issued by
- Ingham County, Michigan
About this file
This bid pack document is issued by Lansing School District for the Ebersole Center Food Service Equipment Replacement and Renovations project (SO-1853), located at 3400 2nd Street, Wayland, Michigan. The project scope includes interior renovations consisting of replacement of food service equipment and lighting, removal of a foldable partition in the multipurpose room, and repairs to existing ceilings across a 4,900 square-foot renovation area within the 7,288 square-foot facility. The project is designed by Colliers Engineering & Design (Architect), with mechanical and electrical engineering services, and food service design by JRA Food Service Consultants. The construction type is 3B non-sprinklered, classified as an "E" educational facility with "A" assembly accessory use. The document establishes that general contractors must coordinate all work across architectural, mechanical, plumbing, and electrical trades, maintain temporary protection and site cleanliness throughout construction, and perform startup testing and commissioning of all equipment and operating systems. The renovation includes replacement of food service equipment such as steamers, convection ovens, dishwashers, ice makers, and various food preparation and serving stations; the scope requires coordination between multiple engineering disciplines for utility connections and infrastructure modifications.
The bid pack requires contractors to review existing conditions and dimensions prior to commencing work and report discrepancies to the architect immediately. All work must comply with the 2021 Michigan Building Code, 2021 Michigan Rehabilitation Code, NFPA 101-2012, 2016 School Fire Safety Rules, and applicable mechanical, plumbing, and electrical codes. Contractors are responsible for providing all materials, labor, schedules, site access management, daily cleaning, final cleaning, protective measures, and equipment startup and testing. The project requires submission of closeout documents including insurance certificates, punch list certifications, maintenance manuals organized by system, operations and maintenance data, project record documents with marked-up record prints, and demonstration and training for owner personnel. Contractors must prepare shop drawings, equipment schedules, and detailed plumbing, electrical, and lighting plans coordinated with food service equipment specifications. The document specifies that substitutions require written approval and documentation of compliance, cost impacts, and manufacturer certifications. Final project submission requires all documentation on digital media in accessible formats with bookmarked PDF files.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
KITCHEN
STORAGE
SERVING
DISHWASHING
WC
MULTI-PORPOSE
ROOM
A-2
3955 SF
/15 = 264
S-1
234 SF
/300 = 1
B
587 SF
/200 = 3
B
129 SF
/200 = 1
RENOVATION SCOPE
DOES NOT INCLUDE
ANY CHANGES TO
EXISTING EGRESS
TRAVEL DISTANCE: 62' - 6"
TRAVEL DISTANCE: 50' - 6"
TRAVEL DISTANCE: 48' - 6"
TRAVEL DISTANCE: 60' - 0"
www.colliersengineering.com
GRAND RAPIDS
560 5th St. NW Suite 305 // Grand Rapids, MI 49504
Phone: 616.827.4270
Colliers Engineering
& Design A
R C
H D x
DRAWING NUMBER:
Copyright © 2025. Colliers Engineering & Design All Rights Reserved. This drawing and all the information contained herein is authorized for use only by the party for whom the services were contracted or to whom it is certified. This drawing may not be copied, reused, disclosed, distributed or relied upon for any other purpose without the express written consent of
Colliers Engineering & Design.
NOTE: DO NOT SCALE DRAWING FOR CONSTRUCTION.
MI ARCHITECTURE
FIRM LICENSE # NLP000605
DRAWING INDEXPROJECT CONTACT LIST
PROJECT LOCATION MAP
OWNER:
LANSING SCHOOL DISTRICT
519 W KALAMAZOO
LANSING, MI
CONTACT: TODD COE
ARCHITECT:
COLLIERS ENGINEERING & DESIGN
560 5TH ST, STE 305
GRAND RAPIDS, MI
CONTACT: COURTNEY NORRIS
PHONE: 616-827-4276
CONTRACTOR:
BECKERING CONSTRUCTION
650 44TH ST SE
GRAND RAPIDS, MI
CONTACT: DAVID BECKERING
MECHANICAL ENGINEER:
COLLIERS ENGINEERING & DESIGN
100 CESAR E CHAVEZ AVE SW, #400
GRAND RAPIDS, MI
CONTACT: LARRY WOOD
ELECTRICAL ENGINEER:
CLASSIC ENGINEERING
100 CESAR E CHAVEZ AVE SW, #400
GRAND RAPIDS, MI
CONTACT: CINDY LADEWIG
CONSULTANT:
JRA FOOD SERVICE CONSULTANTS
3113 W. RIVER ROAD
MUSKEGON, MI 49445
CONTACT: JIM RIEMENSCHNEIDER
PHON: 616-454-4433
CODE REVIEW
BID PACK 2
/1
/2
:4 :4
P
M
EBERSOLE CENTER FOOD SERVICE - EQUIPMENT
REPLACEMENT & RENOVATIONS SO-1853
3400 2ND STREET
WAYLAND, MI 49348
G000
03/13/26
SHEET INDEX
00 - GENERAL
G000 COVER SHEET
04 - ARCHITECTURAL
A001 GENERAL NOTES AND LEGEND
A002 GENERAL REQUIREMENTS
AD101 FIRST FLOOR DEMOLITION PLAN
A101 FIRST FLOOR AND CEILING PLANS
06 - PLUMBING
PD101 FIRST FLOOR PLAN - DEMOLITION
P101 FIRST FLOOR PLAN - PLUMBING
08 - ELECTRICAL
E100 DETAILS, SYMBOL LEGENGS & SPECIFICATIONS
E200 ONE-LINE DIAGRAM
ED101 FIRST FLOOR PLAN - DEMOLITION
EL101 FIRST FLOOR PLAN - LIGHTING / PHOTOMETRICS
EP101 FIRST FLOOR PLAN - POWER
10 - FOOD SERVICE
FSE-0 FOOD SERVICE EQUIPMENT FLOOR PLAN
FSE-1 FOOD SERVICE EQUIPMENT FLOOR PLAN
FSE-2 FOOD SERVICE EQUIPMENT FLOOR PLAN
FSE-3 FOOD SERVICE EQUIPMENT FLOOR PLAN
PROJECT SCOPE
INTERIOR RENOVATIONS CONSISTING OF REPLACEMENT OF FOOD SERVICE EQUIPMENT AND LIGHTING. ADDITIONAL SCOPE IS TO REMOVE A FOLDABLE PARTITION IN THE MULTI-PURPOSE ROOM AND MAKE REPAIRS TO EXISTING
CEILINGS.
APPLICABLE BUILDING CODES
BUILDING CODE: 2021 MICHIGAN BUILDING CODE
2021 MICHIGAN REHABILITATION CODE
MI FIRE SAFETY
STATE RULES: NFPA 101-2012
2016 SCHOOL FIRE SAFETY RULES
MECHANICAL CODE: 2021 MICHIGAN MECHANICAL CODE
PLUMBING CODE: 2021 MICHIGAN PLUMBING CODE
ELECTRICAL CODE: 2023 MICHIGAN ELECTRICAL CODE, PART 8 RULES (BY REFERENCE 2023 NEC)
ACCESSIBILITY: BARRIER FREE - ICC A117.1-2017
ENERGY CODE: 2021 MICHIGAN ENERGY CODE
BUILDING DATA
EXISTING BUILDING AREA: 7,288 SF
CONSTRUCTION TYPE= 3B
NON-SPRINKLERED
RENOVATION AREA: 4,900 SF
USE AND OCCUPANCY
BUILDING IS CLASSIFIED AS "E" EDUCATIONAL, ACCESSORY USE "A" ASSEMBLY
INTERIOR FINISH
SECTION 803 INTERIOR FINISH AND TRIM: NON-SPRINKLERED TABLE 803.11
INTERIOR FINISHES AND TRIM SHALL MEET FLAME SPREAD, SMOKE DEVELOPED AND CLASS RATINGS
AS REQUIRED FOR SPECIFIC USE AND AREA: E
PROJECT LOCATION
SCALE : 3/64" = 1'-0"
LIFE SAFETY PLAN - AREA OF WORK
REV DATE DESCRIPTION
3 03/13/26 BID PACK 2 - BIDS &PERMITS
8' - 0"
XX
CEILING HEIGHT
ELEVATION NOTATION
EQUIPMENT TAG
KEYNOTE (REMOVALS)
KEYNOTE
CAST STONE
GRAVEL OR CRUSHED STONE
CONCRETE
CONCRETE MASONRY UNIT
UNDISTURBED EARTH
BRICK
RIGID INSULATION
PLYWOOD
SAND OR GYPSUM BOARD
STEEL
WOOD FRAMING (CONTINUOUS) BATT INSULATION
WOOD BLOCKING (DISCONTIN.)
EXISTING FINISH WOOD
GENERAL ARCHITECTURAL SYMBOLS
MATERIAL INDICATORS
A101
A101
XXX
XXX
A101
SIM
1Ref
DETAIL CALLOUT
ELEVATION MARKER
DRAWING NO.
ELEVATION
NO.
BREAK MARKER
NORTH ARROW
(SHOWN IN KEYPLAN)
NEW COLUMN ID
DETAIL NO.
DRAWING NO.
EXISTING COLUMN ID
A101
1Ref
R e f
R e f
1Ref
A000
VIEW TITLE
DETAIL NO.
SECTION MARKER
SECTION NO.
DRAWING NO.
DETAIL SECTION
DRAWING NO.
ACCESSORY MARKER
DETAIL NO.
XX
EXISTING DOOR
SCHEDULED DOOR
ROOM TAG
WINDOW TYPE MARKER
DOOR MARKER
Room name
WALL STYLES
EXISTING BRICK WALL
EXISTING CMU WALL
EXISTING STUD WALL
STUD WALL
CMU WALL
BRICK WALL
EXISTING WALL REMOVAL
GENERAL NOTESGENERAL PARTITION NOTES
ALL GENERAL NOTES PERTAIN TO ALL ARCHITECTURAL (A-SERIES) DRAWINGS IN THIS SET
GENERAL
1. DEFINITIONS: “PROVIDE” MEANS FURNISH AND INSTALL. SUPPLY LABOR AND MATERIALS TO RESULT IN A FINISHED AND/OR OPERABLE SYSTEM.
2. CONTRACTOR RESPONSIBILITIES:
A. MATERIALS, CONSTRUCTION METHODS INCLUDING BUT NOT LIMITED TO LAYOUT, COORDINATION, SCHEDULE AND CONSTRUCTION SITE ACCESS AND WORK.
B. DAILY CLEANING: KEEP SITE FREE FROM WASTE, RUBBISH, AND DEBRIS. REMOVE DAILY. WHEN WORK IS COMPLETE, LEAVE THE PREMISES BROOM CLEAN AND CLEAN FINISHED
SURFACES, FIXTURES, GLASS, STOREFRONT, ETC.
C. FINAL CLEANING, PRIOR TO PUNCHLIST INSPECTION BROOM CLEAN ALL HARD SURFACE FLOORS, VACUUM ALL CARPETING AND WIPE DOWN ALL HORIZONTAL AND GLASS
SURFACES PROVIDING A DUST FREE SURFACE.
D. TEMPORARY PROTECTION IS REQUIRED TO MAINTAIN ONGOING BUILDING OPERATIONS, EXITING PATHS, DUST CONTROL AND OCCUPANT SAFETY. IDENTIFY THE REQUIREMENTS FOR TEMPORARY PROTECTION AND PROJECT PHASING. COORDINATE WITH OWNER FOR OTHER REQUIREMENTS.
E. COORDINATE STARTUP AND ADJUSTING OF EQUIPMENT AND OPERATING COMPONENTS. START EQUIPMENT AND OPERATING COMPONENTS AND TEST TO CONFIRM PROPER OPERATION AND CONTROL. REMOVE MALFUNCTIONING UNITS, REPLACE WITH NEW UNITS, AND RETEST.
F. CLOSEOUT DOCUMENTS, CERTIFICATE OF RELEASE FROM THE AUTHORITY OF JURISDICTION AND INSURANCE FOR CONTINUING COVERAGE, WARRANTIES, TEST & INSPECTION
RESULTS AND OPERATION, EMERGENCY & MAINTENANCE MANUALS.
3. EXISTING CONDITIONS: REVIEW EXISTING CONDITIONS AND DIMENSIONS PRIOR TO COMMENCING WORK AND REPORT DISCREPANCIES TO THE ARCHITECT IMMEDIATELY.
4. CONTRACT DOCUMENTS:
A. PLANS, ELEVATIONS, SECTIONS, DETAILS AND SCHEDULES ARE COMPLEMENTARY. PLAN DRAWINGS WILL TAKE PRECEDENCE OVER ELEVATION, SECTION AND DETAILS DRAWINGS
IN ANY CONFLICTS OF HORIZONTAL DIMENSIONS. DETAIL PLAN DRAWINGS WILL TAKE PRECEDENCE OVER LARGER SCALE PLANS IN ANY CONFLICTS WITH HORIZONTAL DIMENSIONS. WALL AND BUILDING SECTIONS WILL TAKE PRECEDENCE OVER PLAN DRAWING AND DETAILS IN ANY CONFLICTS WITH VERTICAL DIMENSIONS. DETAILS AND WALL SECTIONS WILL TAKE PRECEDENCE OVER ELEVATION AND PLAN DRAWINGS IN ANY CONFLICTS WITH MATERIAL DESCRIPTION. SCHEDULES WILL TAKE PRECEDENCE OVER OTHER ARCHITECTURAL DRAWINGS IN AND CONFLICTS WITH WALL, FLOOR AND CEILING FINISHES AND DOOR, DOOR HARDWARE AND FENESTRATION INFORMATION.
B. DRAWINGS PREPARED BY THE ARCHITECT ARE INSTRUMENTS OF THE ARCHITECT'S SERVICE FOR USE SOLELY WITH RESPECT TO THIS PROJECT AND, UNLESS OTHERWISE PROVIDED, BERGMANN SHALL BE DEEMED THE AUTHOR OF THESE DOCUMENTS AND RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE
COPYRIGHT.
C. WHERE REFERENCE IS MADE TO VARIOUS TEST STANDARDS FOR MATERIALS, SUCH STANDARDS SHALL BE THE LATEST EDITION AND/OR ADDENDUM.
FIELD CONDITIONS
1. REPAIR: EXISTING SURFACES TO REMAIN IMPACTED BY DEMOLITION TO MATCH EXISTING ADJACENT SURFACES.
2. DISCREPANCIES: NOTIFY ARCHITECT OF EXISTING DAMAGED OR DETERIORATED BUILDING ELEMENTS REVEALED DURING DEMOLITION OR CONSTRUCTION PRIOR TO PROCEEDING
WITH ADDITIONAL WORK IN THE AREA.
3. SAFETY: FOLLOW THE OCCUPATIONAL SAFETY & HEALTH ADMINISTRATION (OSHA) 29 CFR 1926.62, LEAD EXPOSURE IN CONSTRUCTION REGULATION. MATERIALS HAVING A CONCENTRATION EQUAL OR GREATER THAN 0.5% BY WEIGHT IN LEAD ARE CONSIDERED TO BE LEAD BASED. HOWEVER, OSHA CONSIDERS ANY AMOUNT OF LEAD ENCOUNTERED DURING CONSTRUCTION TO BE OF CONCERN. THE REGULATION STATES THAT THE EMPLOYER SHALL ASSURE THAT NO EMPLOYEE IS EXPOSED TO LEAD AT CONCENTRATIONS GREATER THAN FIFTY MICROGRAMS PER CUBIC METER OF AIR (50 MG/M^3) AVERAGED OVER AN 8-HOUR PERIOD. CONTRACTORS SHALL DETERMINE AND TAKE APPROPRIATE
MEASURES IF THEY SUSPECT THE PRESENCE OF LEAD.
FINISHES
A. GENERAL: FINISHED FLOORS EXTEND INTO TOE SPACES,UNDER CASEWORK ON LAB PROJECTS, CLOSETS, DOOR REVEALS AND SIMILAR OPENINGS.
B. PRODUCTS:
A. INSTALL MATERIALS USING MANUFACTURER'S APPROVED ADHESIVES AND METHODS, U.N.O.
B. PAINT DESIGNATIONS INDICATE COLOR ONLY, REFER TO SPECIFICATION FOR FINISH TYPE.
C. PROVIDE SELF LEVELING TROWELABLE UNDERLAYMENT WHERE REQUIRED TO OBTAIN FINISH MANUFACTURER'S REQUIRED SUBFLOOR CONDITION.
C. EXECUTION:
A. ADHERE TO MATERIAL OR SYSTEM MANUFACTURER’S WRITTEN INSTALLATION INSTRUCTIONS AND TOLERANCES. ANY VARIATIONS FROM WRITTEN INSTALLATION AND
INSTRUCTIONS MUST RECEIVE WRITTEN APPROVAL FROM THE MANUFACTURER AND MAINTAIN MANUFACTURER’S WARRANTIES.
B. PRIOR TO STARTING THE INSTALLATION OF A MATERIAL OR SYSTEM, VERIFY THE SUBSTRATE IS WITHIN THE MANUFACTURER’S REQUIRED TOLERANCES AND REQUIRED CLEARANCES ARE PROVIDED. NOTIFY THE CONSTRUCTION MANAGER OR GENERAL CONTRACTOR AND DEIGN PROFESSIONAL IN WRITING WHEN THE SUBSTRATE IS NOT WITHIN MANUFACTURER’S TOLERANCE OR REQUIRED CLEARANCES ARE NOT PROVIDED. PROCEEDING WITH INSTALLATION SIGNIFIES ACCEPTANCE OF THE SUBSTRATE AND
CLEARANCES.
C. PROVIDE MANUFACTURER’S REQUIRED ENVIRONMENTAL TESTS FOR MOISTURE, VAPOR DRIVE, RELATIVE HUMIDITY AND TEMPERATURE TO VERIFY THESE ARE WITHIN THE
MATERIAL MANUFACTURER’S TOLERANCE PRIOR TO INSTALLING MATERIALS.
D. MATERIAL AND INSTALLATION SHALL CONFORM WITH LOCAL, STATE AND NATIONAL BUILDING CODES AND CONSTRUCTION STANDARDS ENFORCED BY THE AUTHORITY HAVING
JURISDICTION.
E. REQUIRED DOCUMENTATION:
1. SAFETY DATA SHEETS.
2. PROVIDE SAMPLES FOR ALL FINISH MATERIALS.
3. PROVIDE SHOP DRAWINGS OF MATERIALS AND SYSTEMS, WHICH WILL BE BUILT INTO AND MUST BE COORDINATED WITH OTHER CONSTRUCTION. SHOP DRAWINGS SHALL
CONSIST OF PLAN, ELEVATION, SECTION VIEWS AND DETAILS AS REQUIRED TO COMMUNICATE FINAL APPEARANCE AND CONNECTION TO ADJOINING CONSTRUCTION.
F. PROTECT ADJACENT SURFACES DURING WORK.
G. REMOVE ADHESIVE OR PAINT SPOTS FROM FINISHED FLOORS, WALLS, GLASS OR OTHER SURFACES. FINISHES TO MEET OR EXCEED CODE REQUIREMENTS.
H. FILL MINOR DRYWALL IRREGULARITIES WITH SPACKLING COMPOUND AND SAND TO A SMOOTH LEVEL SURFACE. EXERCISE CARE TO AVOID RAISING THE NAP OF PAPER.
I. DO NOT PERFORM PAINTING AND OTHER FINISHING WORK UNDER CONDITIONS UNSUITABLE FOR EXECUTION OF PAINTING WORK. AIR SHALL BE FREE FROM DUST AND DIRT TO PREVENT LODGING OF FOREIGN MATTER IN FRESH PAINT. FLOORS TO BE BROOM CLEAN BEFORE PAINTING IS STARTED.
J. EDGES OF PAINT ADJOINING OTHER COLORS OR MATERIALS TO BE SHARP AND CLEAN WITHOUT OVERLAP.
K. WHENEVER NECESSARY TO OBTAIN REQUIRED RESULTS, REFINISH AN ENTIRE WALL RATHER THAN SPOT FINISHING WHERE A PORTION OF THE FINISH HAS BEEN DAMAGED OR IS
UNSATISFACTORY.
WALLS
A. DIMENSIONS:
a. STUD WALLS ARE TO FACE OF STUD, UNLESS OTHERWISE INDICATED IN A.c. OR A.d. BELOW.
b. MASONRY WALLS ARE TO FACE OF MASONRY.
c. EXISTING CONSTRUCTION ARE TO FINISHED FACE OF CONSTRUCTION.
d. WHERE NOTED AS “CLR” DIMENSIONS ARE TO FINISHED SURFACE AND ARE CRITICAL FOR ACCESSIBILITY
REQUIREMENTS OR BUILT-IN FURNISHINGS.
B. RATINGS:
a. SMOKE WALLS AND SMOKE BARRIERS: SMOKE WALLS AND SMOKE BARRIERS MUST FORM A COMPLETE BARRIER TO
LIMIT THE TRANSFER OF SMOKE, INCLUDING PERIMETER DETAILS, PENETRATIONS, AND AS REQUIRED BETWEEN WALLS AND DOOR JAMBS, OR SIDELIGHT FRAMES. THE MEMBRANE IS TO BE CONTINUOUS THROUGH ALL CONCEALED
SPACES.
1. RECESSED CABINETS, OUTLET BOXES, AND OTHER PENETRATIONS MUST BE SEALED
2. OPENINGS AROUND PENETRATIONS ARE TO BE SEALED.
3. ALL EXPOSED JOINTS, ANGLES, AND ABUTMENTS IN THE SYSTEM, INCLUDING FLOOR AND ABOVE CEILING MUST BE
TAPED AND FINISHED.
4. SEAL THE INTERFACE BETWEEN WALLS AND DOOR JAMBS, OR SIDELIGHT FRAMES.
b. FIRE WALLS AND FIRE BARRIERS: FIRE WALLS AND FIRE BARRIERS MUST BE SIMILARLY CONSTRUCTED AS A COMPLETE BARRIER TO RESIST THE SPREAD OF SMOKE AND FIRE. PENETRATIONS MUST BE SEALED AND LABELED WITH AN APPROVED FIRE RESISTANT JOINT SYSTEM. INSTALL A FIRE RESISTANT JOINT SYSTEM AT THE HEAD AND
FLOOR CONDITION OF FIRE RATED WALLS AND BARRIERS.
c. FIRE AND SMOKE WALL / BARRIER / WALLS LABELING:
1. WHERE THERE IS AN ACCESSIBLE CONCEALED FLOOR, FLOOR-CEILING, OR ATTIC SPACE, FIRE WALLS, FIRE
BARRIERS, FIRE PARTITIONS, SMOKE BARRIERS, AND SMOKE PARTITIONS OR ANY OTHER WALL REQUIRED TO HAVE PROTECTED OPENINGS OR PENETRATIONS SHALL BE EFFECTIVELY AND PERMANENTLY IDENTIFIED WITH
SIGNS OR STENCILING IN THE CONCEALED SPACE. SUCH IDENTIFICATION SHALL:
A. BE LOCATED WITHIN 15 FEET (4572 MM) OF THE END OF EACH WALL AND AT INTERVALS NOT EXCEEDING 30
FEET (9144 MM) MEASURED HORIZONTALLY ALONG THE WALL OR PARTITION.
B. INCLUDE LETTERING NOT LESS THAN 3 INCHES (76 MM) IN HEIGHT WITH A MINIMUM 3/8-INCH (9.5 MM) STROKE IN A CONTRASTING COLOR INCORPORATING THE SUGGESTED WORDING, “FIRE AND/OR SMOKE BARRIER –
PROTECT ALL OPENEINGS,” OR OTHER WORDING.
d. ACOUSTICAL WALLS: WALLS INDICATED WITH ACOUSTICAL BATT, AND/OR A GIVEN AN STC RATING, SHALL BE
CONSTRUCTED TO MINIMIZE SOUND TRANSMISSION AS FOLLOWS:
1. PROVIDE ACOUSTICAL SEALANT AT ALL FLOOR AND HEAD LEVELS, EACH SIDE OF THE WALLS.
2. SET TRACK IN 3 CONTINUOUS BEADS OF ACOUSTICAL SEALANT.
3. EXTEND SOUND BATTS THOROUGH ANY INTERSECTING WALLS.
4. STAGGER OUTLETS A MINIMUM OF 24 INCHES HORIZONTAL. DO NOT INSTALL MORE THAN ONE OUTLET IN A
COMMON STUD CAVITY. SEAL JOINTS AROUND OUTLETS WITH ACOUSTICAL SEALANT.
Colliers Engineering & Design, Architecture, Landscape Architecture, Surveying, CT P.C.
Colliers
Engineering & Design
Colliers
Engineering & Design
GRAND RAPIDS
560 5th St. NW
Suite 305
Grand Rapids, MI 49504
Phone: 616.827.4270
A R
C H
D x
PROJECT MANAGER:
DESIGNER: REVIEWER:
DISCIPLINE LEAD:
DRAWING NUMBER:
DATE ISSUED: PROJECT NUMBER:
SHEET NAME:
Copyright © 2024. Colliers Engineering & Design All Rights Reserved. This drawing and all the information contained herein is authorized for use only by the party for whom the services were contracted or to whom it is certified. This drawing may not be copied, reused, disclosed, distributed or relied upon for any other purpose without the express written consent of
Colliers Engineering & Design.
www.colliersengineering.com
NOTE: DO NOT SCALE DRAWING FOR CONSTRUCTION.
MI ARCHITECTURE
FIRM LICENSE # NLP000605
BID PACK 2
/1
/2
:4 :4
P
M
EBERSOLE CENTER FOOD
SERVICE - EQUIPMENT
REPLACEMENT &
RENOVATIONS SO-1853
3400 2ND STREET
WAYLAND, MI 49348
C NORRIS
E. POST
B. HUYLER
A001
GENERAL NOTES AND
LEGEND
LANSING SCHOOL
DISTRICT
03/13/26 26000750A
QUALITY REQUIREMENTS:
A. CONFLICTING STANDARDS AND OTHER REQUIREMENTS: IF COMPLIANCE WITH TWO OR MORE STANDARDS OR REQUIREMENTS IS SPECIFIED AND THE STANDARDS OR REQUIREMENTS ESTABLISH DIFFERENT OR CONFLICTING REQUIREMENTS FOR MINIMUM QUANTITIES OR QUALITY LEVELS, INFORM THE ARCHITECT REGARDING THE CONFLICT AND OBTAIN CLARIFICATION PRIOR TO PROCEEDING WITH THE WORK. REFER CONFLICTING REQUIREMENTS THAT ARE DIFFERENT, BUT APPARENTLY EQUAL, TO ARCHITECT FOR CLARIFICATION BEFORE PROCEEDING.
B. PREPARE AND SUBMIT CERTIFIED WRITTEN REPORTS REQUIRED. INCLUDE THE FOLLOWING:
1. PROJECT TITLE AND NUMBER AND DATE OF ISSUE. RECORD OF TEMPERATURE AND WEATHER CONDITIONS AT TIME OF SAMPLE TAKING AND
TESTING AND INSPECTION. NAME AND SIGNATURE OF LABORATORY INSPECTOR.
2. NAME, ADDRESS, TELEPHONE NUMBER, AND EMAIL ADDRESS OF TESTING AGENCY
3. DATES AND LOCATIONS OF SAMPLES AND TESTS OR INSPECTIONS.
4. TEST AND INSPECTION RESULTS AND AN INTERPRETATION OF TEST RESULTS. COMMENTS OR PROFESSIONAL OPINION ON WHETHER TESTED OR INSPECTED WORK COMPLIES WITH THE CONTRACT DOCUMENT REQUIREMENTS. RECOMMENDATIONS ON RETESTING AND REINSPECTING.
C. MANUFACTURER QUALIFICATIONS: A FIRM EXPERIENCED IN MANUFACTURING PRODUCTS OR SYSTEMS SIMILAR TO THOSE INDICATED FOR THIS PROJECT AND WITH A RECORD OF SUCCESSFUL IN-SERVICE PERFORMANCE, AS WELL AS SUFFICIENT PRODUCTION CAPACITY TO PRODUCE REQUIRED UNITS. AS APPLICABLE, PROCURE PRODUCTS FROM MANUFACTURERS ABLE TO MEET QUALIFICATION REQUIREMENTS, WARRANTY REQUIREMENTS, AND TECHNICAL OR FACTORY-AUTHORIZED SERVICE REPRESENTATIVE REQUIREMENTS.
D. FABRICATOR QUALIFICATIONS: A FIRM EXPERIENCED IN PRODUCING PRODUCTS SIMILAR TO THOSE INDICATED FOR THIS PROJECT AND WITH A RECORD OF SUCCESSFUL IN-SERVICE PERFORMANCE, AS WELL AS SUFFICIENT PRODUCTION CAPACITY TO PRODUCE REQUIRED UNITS.
E. INSTALLER QUALIFICATIONS: A FIRM OR INDIVIDUAL EXPERIENCED IN INSTALLING, ERECTING, APPLYING, OR ASSEMBLING WORK SIMILAR IN MATERIAL, DESIGN, AND EXTENT TO THAT INDICATED FOR THIS PROJECT, WHOSE WORK HAS RESULTED IN CONSTRUCTION WITH A RECORD OF
SUCCESSFUL IN-SERVICE PERFORMANCE.
F. TESTING AND INSPECTING AGENCY QUALIFICATIONS: AN NRTL, AN NVLAP, OR AN INDEPENDENT AGENCY WITH THE EXPERIENCE AND CAPABILITY TO CONDUCT TESTING AND INSPECTION INDICATED, AS DOCUMENTED ACCORDING TO [ASTM E329] <INSERT STANDARD>; AND WITH ADDITIONAL QUALIFICATIONS REQUIRED BY THE CONSTRUCTION DOCUMENTS; AND, WHERE REQUIRED BY AUTHORITIES HAVING JURISDICTION, THAT IS
ACCEPTABLE TO AUTHORITIES.
G. PRECONSTRUCTION TESTING: WHERE TESTING AGENCY IS INDICATED TO PERFORM PRECONSTRUCTION TESTING FOR COMPLIANCE WITH SPECIFIED REQUIREMENTS FOR PERFORMANCE AND TEST METHODS, COMPLY WITH THE FOLLOWING:
1. CONTRACTOR RESPONSIBILITIES INCLUDE THE FOLLOWING: PROVIDE TEST SPECIMENS REPRESENTATIVE OF PROPOSED PRODUCTS AND CONSTRUCTION. SUBMIT SPECIMENS IN A TIMELY MANNER WITH SUFFICIENT TIME FOR TESTING AND ANALYZING RESULTS TO PREVENT DELAYING THE WORK. WHEN TESTING IS COMPLETE, REMOVE TEST SPECIMENS AND TEST ASSEMBLIES, AND MOCKUPS UNLESS NOTED
OTHERWISE; DO NOT REUSE PRODUCTS ON PROJECT.
2. TESTING AGENCY RESPONSIBILITIES: SUBMIT A CERTIFIED WRITTEN REPORT OF EACH TEST, INSPECTION, AND SIMILAR QUALITY-ASSURANCE SERVICE TO ARCHITECT, CONTRACTOR OR CONSTRUCTION MANAGER AND COMMISSIONING AUTHORITY. INTERPRET TESTS AND INSPECTIONS AND STATE IN EACH REPORT WHETHER TESTED AND INSPECTED WORK COMPLIES WITH OR DEVIATES FROM THE CONTRACT DOCUMENTS.
H. MOCKUPS: BEFORE INSTALLING PORTIONS OF THE WORK REQUIRING MOCKUPS, BUILD MOCKUPS FOR EACH FORM OF CONSTRUCTION AND FINISH REQUIRED TO COMPLY WITH THE FOLLOWING REQUIREMENTS, USING MATERIALS INDICATED FOR THE COMPLETED WORK, TO SIZE AND LOCATION INDICATED. DEMONSTRATE THE PROPOSED RANGE OF AESTHETIC EFFECTS AND WORKMANSHIP. NOTIFY ARCHITECT, CONTRACTOR AND CONSTRUCTION MANAGER 7 DAYS IN ADVANCE OF DATES AND TIMES WHEN MOCKUPS WILL BE CONSTRUCTED AND ALLOW 7 DAYS FOR REVIEW
AND APPROVAL. OBTAIN THE APPROVAL FROM ARCHITECT, CONTRACTOR AND CONSTRUCTION MANAGER BEFORE STARTING CORRESPONDING WORK, FABRICATION, OR CONSTRUCTION. MAINTAIN MOCKUPS DURING CONSTRUCTION IN AN UNDISTURBED CONDITION AS A STANDARD FOR JUDGING THE COMPLETED WORK. DEMOLISH AND REMOVE MOCKUPS WHEN DIRECTED UNLESS OTHERWISE INDICATED.
I. QUALITY CONTROL:
1. CONTRACTOR RESPONSIBILITIES: TESTS AND INSPECTIONS ARE CONTRACTOR'S RESPONSIBILITY. PERFORM ADDITIONAL QUALITY-CONTROL ACTIVITIES, WHETHER SPECIFIED OR NOT, TO VERIFY AND DOCUMENT THAT THE WORK COMPLIES WITH REQUIREMENTS. ENGAGE A QUALIFIED TESTING AGENCY TO PERFORM QUALITY-CONTROL SERVICES. NOTIFY TESTING AGENCIES AT LEAST [72] HOURS IN ADVANCE OF TIME WHEN WORK THAT REQUIRES TESTING OR INSPECTION WILL BE PERFORMED. COOPERATE WITH AGENCIES AND REPRESENTATIVES PERFORMING REQUIRED TESTS, INSPECTIONS, AND SIMILAR QUALITY-CONTROL SERVICES, AND PROVIDE REASONABLE AUXILIARY SERVICES AS REQUESTED.
2. TESTING AGENCY RESPONSIBILITIES: COOPERATE WITH ARCHITECT, CONTRACTOR OR CONSTRUCTION MANAGER AND COMMISSIONING
AUTHORITY IN PERFORMANCE OF DUTIES. PROVIDE QUALIFIED PERSONNEL TO PERFORM REQUIRED TESTS AND INSPECTIONS. INTERPRET TESTS AND INSPECTIONS AND STATE IN EACH REPORT WHETHER TESTED AND INSPECTED WORK COMPLIES WITH OR DEVIATES FROM REQUIREMENTS. NOTIFY ARCHITECT, CONTRACTOR OR CONSTRUCTION MANAGER AND COMMISSIONING AUTHORITY PROMPTLY OF IRREGULARITIES OR DEFICIENCIES OBSERVED IN THE WORK DURING PERFORMANCE OF ITS SERVICES.
3. CONTRACTOR AND TESTING AGENCY SHALL COORDINATE SEQUENCE OF ACTIVITIES TO ACCOMMODATE REQUIRED QUALITY-ASSURANCE AND QUALITY-CONTROL SERVICES WITH A MINIMUM OF DELAY AND TO AVOID NECESSITY OF REMOVING AND REPLACING CONSTRUCTION TO
ACCOMMODATE TESTING AND INSPECTION.
J. SPECIAL TESTS AND INSPECTIONS: OWNER WILL ENGAGE A QUALIFIED TESTING AGENCY OR SPECIAL INSPECTOR TO CONDUCT SPECIAL TESTS AND INSPECTIONS REQUIRED BY AUTHORITIES HAVING JURISDICTION AS THE RESPONSIBILITY OF OWNER AS INDICATED IN THE STATEMENT OF
SPECIAL INSPECTIONS, AND AS FOLLOWS:
1. VERIFYING THAT MANUFACTURER MAINTAINS DETAILED FABRICATION AND QUALITY-CONTROL PROCEDURES AND REVIEWING THE
COMPLETENESS AND ADEQUACY OF THOSE PROCEDURES TO PERFORM THE WORK.
2. NOTIFY ARCHITECT, CONTRACTOR OR CONSTRUCTION MANAGER AND COMMISSIONING AUTHORITY PROMPTLY OF IRREGULARITIES OR
DEFICIENCIES OBSERVED IN THE WORK DURING PERFORMANCE OF ITS SERVICES.
3. SUBMITTING A CERTIFIED WRITTEN REPORT OF EACH TEST, INSPECTION, AND SIMILAR QUALITY-CONTROL SERVICE TO ARCHITECT, CONTRACTOR OR CONSTRUCTION MANAGER AND COMMISSIONING AUTHORITY WITH COPY TO CONTRACTOR AND TO AUTHORITIES HAVING JURISDICTION. SUBMIT A FINAL REPORT OF SPECIAL TESTS AND INSPECTIONS AT SUBSTANTIAL COMPLETION, WHICH INCLUDES A LIST OF
UNRESOLVED DEFICIENCIES.
4. RETESTING AND REINSPECTING CORRECTED WORK.
K. ALL RETESTING/REINSPECTING: REGARDLESS OF WHETHER ORIGINAL TESTS OR INSPECTIONS WERE CONTRACTOR'S RESPONSIBILITY OR THE OWNER’S SPECIAL INSPECTIONS, PROVIDE QUALITY-CONTROL SERVICES, INCLUDING RETESTING AND REINSPECTING, FOR CONSTRUCTION THAT
REPLACED WORK THAT FAILED TO COMPLY WITH THE CONTRACT DOCUMENTS.
CONSTRUCTION WASTE MANAGEMENT:
A. DEVELOP A WASTE MANAGEMENT PLAN AND SUBMIT PLAN FOR APPROVAL WITHIN 14 DAYS OF DATE ESTABLISHED FOR COMMENCEMENT OF THE
WORK.
B. DISTRIBUTE AND IMPLEMENT APPROVED WASTE MANAGEMENT PLAN. PROVIDE HANDLING, CONTAINERS, STORAGE, SIGNAGE, TRANSPORTATION, AND OTHER ITEMS AS REQUIRED TO IMPLEMENT WASTE MANAGEMENT PLAN DURING THE ENTIRE DURATION OF THE CONTRACT.
C. TRAIN WORKERS, SUBCONTRACTORS, AND SUPPLIERS ON PROPER WASTE MANAGEMENT PROCEDURES, AS APPROPRIATE FOR THE WORK.
D. SITE ACCESS AND TEMPORARY CONTROLS: CONDUCT WASTE MANAGEMENT OPERATIONS TO ENSURE MINIMUM INTERFERENCE WITH ROADS, STREETS, WALKS, WALKWAYS, AND OTHER ADJACENT OCCUPIED AND USED FACILITIES. DESIGNATE AND LABEL SPECIFIC AREAS ON PROJECT SITE
NECESSARY FOR SEPARATING MATERIALS THAT ARE TO BE SALVAGED AND RECYCLED.
CLOSEOUT PROCEDURES:
A. CONTRACTOR'S LIST OF INCOMPLETE ITEMS: PREPARE AND SUBMIT A LIST OF ITEMS TO BE COMPLETED AND CORRECTED (CONTRACTOR'S "PUNCH LIST"), INDICATING THE VALUE OF EACH ITEM ON THE LIST AND REASONS WHY THE WORK IS INCOMPLETE.
B. SUBMITTALS PRIOR TO SUBSTANTIAL COMPLETION: COMPLETE THE FOLLOWING A MINIMUM OF 10 DAYS PRIOR TO REQUESTING INSPECTION FOR
DETERMINING DATE OF SUBSTANTIAL COMPLETION.
1. SUBMIT A FINAL APPLICATION FOR PAYMENT.
2. CERTIFICATE OF INSURANCE: SUBMIT EVIDENCE OF FINAL, CONTINUING INSURANCE COVERAGE.
3. CERTIFIED LIST OF INCOMPLETE ITEMS: SUBMIT CERTIFIED COPY OF ARCHITECT'S SUBSTANTIAL COMPLETION INSPECTION LIST OF ITEMS TO BE COMPLETED OR CORRECTED (PUNCH LIST), ENDORSED AND DATED BY ARCHITECT. CERTIFIED COPY OF THE LIST SHALL STATE THAT EACH ITEM
HAS BEEN COMPLETED OR OTHERWISE RESOLVED FOR ACCEPTANCE.
4. CERTIFICATES OF RELEASE: OBTAIN AND SUBMIT RELEASES FROM AUTHORITIES HAVING JURISDICTION, PERMITTING OWNER UNRESTRICTED USE OF THE WORK AND ACCESS TO SERVICES AND UTILITIES. INCLUDE OCCUPANCY PERMITS, OPERATING CERTIFICATES, AND SIMILAR
RELEASES.
5. SUBMIT CLOSEOUT SUBMITTALS AS REQUIRED, INCLUDING SPECIFIC WARRANTIES, WORKMANSHIP BONDS, MAINTENANCE SERVICE
AGREEMENTS, FINAL CERTIFICATIONS, AND SIMILAR DOCUMENTS.
6. SUBMIT MAINTENANCE MATERIAL SUBMITTALS SPECIFIED IN INDIVIDUAL SECTIONS, INCLUDING TOOLS, SPARE PARTS, EXTRA MATERIALS, AND SIMILAR ITEMS, AND DELIVER TO LOCATION DESIGNATED BY OWNER OR OWNER’S AGENT. LABEL WITH MANUFACTURER'S NAME AND MODEL
NUMBER.
7. SUBMIT TESTING, ADJUSTING, AND BALANCING RECORDS.
8. SUBMIT CHANGEOVER INFORMATION RELATED TO OWNER'S OCCUPANCY, USE, OPERATION, AND MAINTENANCE.
9. ALL CLOSE OUT DOCUMENTS TO BE SUBMITTED TO OWNER BY SINGLE THUMB DRIVE
C. FINAL CLEANING
1. EMPLOY EXPERIENCED WORKERS OR PROFESSIONAL CLEANERS FOR FINAL CLEANING. CLEAN EACH SURFACE OR UNIT TO CONDITION EXPECTED IN AN AVERAGE COMMERCIAL BUILDING CLEANING AND MAINTENANCE PROGRAM. COMPLY WITH
MANUFACTURER'S WRITTEN INSTRUCTIONS.
2. USE CLEANING PRODUCTS THAT COMPLY WITH GREEN SEAL'S GS-37, OR IF GS-37 IS NOT APPLICABLE, USE PRODUCTS THAT
COMPLY WITH THE CALIFORNIA CODE OF REGULATIONS MAXIMUM ALLOWABLE VOC LEVELS.
3. CLEAN EXPOSED EXTERIOR AND INTERIOR HARD-SURFACED FINISHES TO A DIRT-FREE CONDITION, FREE OF STAINS, FILMS, AND
SIMILAR FOREIGN
SUBSTANCES. AVOID DISTURBING NATURAL WEATHERING OF EXTERIOR SURFACES. RESTORE REFLECTIVE SURFACES TO THEIR
ORIGINAL CONDITION.
4. VACUUM CARPET AND SIMILAR SOFT SURFACES, REMOVING DEBRIS AND EXCESS NAP; CLEAN ACCORDING TO MANUFACTURER'S
RECOMMENDATIONS IF VISIBLE SOIL OR STAINS REMAIN.
5. CLEAN TRANSPARENT MATERIALS, INCLUDING MIRRORS AND GLASS IN DOORS AND WINDOWS. REMOVE GLAZING COMPOUNDS AND OTHER NOTICEABLE, VISION-OBSCURING MATERIALS. POLISH MIRRORS AND GLASS, TAKING CARE NOT TO SCRATCH
SURFACES.
6. CLEAN PLUMBING FIXTURES TO A SANITARY CONDITION, FREE OF STAINS, INCLUDING STAINS RESULTING FROM WATER
EXPOSURE.
OPERATIONS AND MAINTENANCE DATA:
A. SUBMIT EACH MANUAL IN FINAL FORM PRIOR TO REQUESTING INSPECTION FOR SUBSTANTIAL COMPLETION AND AT LEAST 10 DAYS
BEFORE COMMENCING DEMONSTRATION AND TRAINING.
B. CORRECT OR REVISE EACH MANUAL TO COMPLY WITH ARCHITECT'S AND COMMISSIONING AUTHORITY'S COMMENTS. SUBMIT COPIES
OF EACH CORRECTED MANUAL WITHIN 10 DAYS OF RECEIPT OF ARCHITECT'S AND COMMISSIONING AUTHORITY'S COMMENTS AND
PRIOR TO COMMENCING DEMONSTRATION AND TRAINING.
C. SUBMIT ON DIGITAL MEDIA ACCEPTABLE TO ARCHITECT BY UPLOADING TO WEB-BASED PROJECT SOFTWARE SITE OR BY EMAIL TO
ARCHITECT, IF WEB-BASED SOFTWARE IS NOT UTILIZED. ENABLE REVIEWER COMMENTS ON DRAFT SUBMITTALS.
1. ELECTRONIC FILES: USE ELECTRONIC FILES PREPARED BY MANUFACTURER WHERE AVAILABLE. WHERE SCANNING OF PAPER
DOCUMENTS IS REQUIRED, CONFIGURE SCANNED FILE FOR MINIMUM READABLE FILE SIZE.
2. BOOKMARK INDIVIDUAL DOCUMENTS BASED ON FILE NAMES. NAME DOCUMENT FILES TO CORRESPOND TO SYSTEM, SUBSYSTEM, AND EQUIPMENT NAMES USED IN MANUAL DIRECTORY AND TABLE OF CONTENTS. GROUP DOCUMENTS FOR EACH SYSTEM AND SUBSYSTEM INTO INDIVIDUAL COMPOSITE BOOKMARKED FILES, THEN CREATE COMPOSITE MANUAL, SO THAT RESULTING BOOKMARKS REFLECT THE SYSTEM, SUBSYSTEM, AND EQUIPMENT NAMES IN A READILY NAVIGATED FILE TREE. CONFIGURE
ELECTRONIC MANUAL TO DISPLAY BOOKMARK PANEL ON OPENING FILE.
D. ORGANIZATION OF MANUALS: UNLESS OTHERWISE INDICATED, ORGANIZE EACH MANUAL INTO A SEPARATE SECTION FOR EACH SYSTEM AND SUBSYSTEM, AND A SEPARATE SECTION FOR EACH PIECE OF EQUIPMENT NOT PART OF A SYSTEM. PROVIDE A TITLE
PAGE AND TABLE OF CONTENTS.
1. TITLE PAGE SHALL INCLUDE:
a. SUBJECT MATTER INCLUDED IN MANUAL.
b. DATE OF SUBMITTAL.
c. NAME AND CONTACT INFORMATION FOR CONTRACTOR AND CONSTRUCTION MANAGER WHEN APPLICABLE.
d. NAME AND CONTACT INFORMATION FOR COMMISSIONING AUTHORITY.
2. EMERGENCY MANUAL: ASSEMBLE A COMPLETE SET OF EMERGENCY INFORMATION INDICATING PROCEDURES FOR USE BY EMERGENCY PERSONNEL AND BY OWNER'S OPERATING PERSONNEL FOR TYPES OF EMERGENCIES INDICATED.
3. SYSTEMS AND EQUIPMENT OPERATION MANUAL: ASSEMBLE A COMPLETE SET OF DATA INDICATING OPERATION OF EACH SYSTEM, SUBSYSTEM, AND PIECE OF EQUIPMENT NOT PART OF A SYSTEM. INCLUDE INFORMATION REQUIRED FOR DAILY OPERATION AND MANAGEMENT, OPERATING STANDARDS, AND ROUTINE AND SPECIAL OPERATING PROCEDURES.
4. SYSTEMS AND EQUIPMENT MAINTENANCE MANUALS: ASSEMBLE A COMPLETE SET OF DATA INDICATING MAINTENANCE OF EACH SYSTEM, SUBSYSTEM, AND PIECE OF EQUIPMENT NOT PART OF A SYSTEM. INCLUDE MANUFACTURERS' MAINTENANCE DOCUMENTATION, PREVENTIVE MAINTENANCE PROCEDURES AND FREQUENCY, REPAIR PROCEDURES, WIRING AND SYSTEMS
DIAGRAMS, LISTS OF SPARE PARTS, AND WARRANTY INFORMATION.
5. PRODUCT MAINTENANCE MANUAL: ASSEMBLE A COMPLETE SET OF MAINTENANCE DATA INDICATING CARE AND MAINTENANCE OF
EACH PRODUCT, MATERIAL, AND FINISH INCORPORATED INTO THE WORK.
PROJECT RECORD DOCUMENTS:
A. RECORD PRINTS: MAINTAIN ONE SET OF MARKED-UP PAPER COPIES OF THE CONTRACT DRAWINGS AND SHOP DRAWINGS, INCORPORATING NEW AND REVISED DRAWINGS AS MODIFICATIONS ARE ISSUED.
B. MAINTAIN ONE COPY OF EACH SUBMITTAL DURING THE CONSTRUCTION PERIOD FOR PROJECT RECORD DOCUMENT PURPOSES.
POST CHANGES AND REVISIONS TO PROJECT RECORD DOCUMENTS AS THEY OCCUR; DO NOT WAIT UNTIL END OF PROJECT.
C. RECORD DIGITAL DATA FILES: IMMEDIATELY BEFORE INSPECTION FOR CERTIFICATE OF SUBSTANTIAL COMPLETION, REVIEW MARKED-UP RECORD DOCUMENTS WITH ARCHITECT, CONTRACTOR. WHEN AUTHORIZED, PREPARE A FULL SET OF CORRECTED DIGITAL DATA FILES OF THE CONTRACT DOCUMENTS. SEE OPERATIONS AND MAINTENANCE DATA SECTION ABOVE FOR SUBMISSION
FORMAT REQUIREMENTS.
DEMONSTRATION AND TRAINING:
A. FACILITATOR: CONTRACTOR OR CONSTRUCTION MANAGER SHALL PREPARE INSTRUCTION PROGRAM AND TRAINING MODULES, TO COORDINATE INSTRUCTORS, AND TO COORDINATE BETWEEN CONTRACTOR AND OWNER FOR NUMBER OF PARTICIPANTS, INSTRUCTION TIMES, AND LOCATION.
B. ENGAGE QUALIFIED INSTRUCTORS TO INSTRUCT OWNER'S PERSONNEL TO ADJUST, OPERATE, AND MAINTAIN SYSTEMS, SUBSYSTEMS, AND EQUIPMENT NOT PART OF A SYSTEM.
C. PROVIDE INSTRUCTION AT MUTUALLY AGREED-ON TIMES. FOR EQUIPMENT THAT REQUIRES SEASONAL OPERATION, PROVIDE
SIMILAR INSTRUCTION AT START OF EACH SEASON.
D. TRAINING LOCATION AND REFERENCE MATERIAL: CONDUCT TRAINING ON-SITE IN THE COMPLETED AND FULLY OPERATIONAL FACILITY USING THE ACTUAL EQUIPMENT IN-PLACE. CONDUCT TRAINING USING FINAL OPERATION AND MAINTENANCE DATA
SUBMITTALS.
E. EVALUATION: AT CONCLUSION OF EACH TRAINING MODULE, ASSESS AND DOCUMENT EACH PARTICIPANT'S MASTERY OF MODULE BY
USE A DEMONSTRATION PERFORMANCE-BASED TEST.
F. COLLECT USED AND LEFTOVER EDUCATIONAL MATERIALS AND GIVE TO OWNER. REMOVE INSTRUCTIONAL EQUIPMENT. RESTORE
SYSTEMS AND EQUIPMENT TO CONDITION EXISTING BEFORE INITIAL TRAINING USE.
GENERAL REQUIREMENTS:
SUBSTITUTION PROCEDURES:
A. SUBSTITUTIONS FOR CAUSE: CHANGES PROPOSED BY CONTRACTOR THAT ARE REQUIRED DUE TO CHANGED PROJECT CONDITIONS, SUCH AS UNAVAILABILITY OF PRODUCT, REGULATORY CHANGES, OR UNAVAILABILITY OF REQUIRED WARRANTY TERMS.
B. SUBSTITUTIONS FOR CONVENIENCE: CHANGES PROPOSED BY CONTRACTOR OR OWNER THAT ARE NOT REQUIRED IN ORDER TO MEET OTHER PROJECT REQUIREMENTS BUT MAY OFFER ADVANTAGE TO CONTRACTOR OR OWNER. SUBSTITUTIONS FOR CONVENIENCE ARE ALLOWED ONLY BY APPROVAL OF
THE OWNER OR OWNER’S AGENT.
C. SUBMIT REQUEST FOR CONSIDERATION. IDENTIFY PRODUCT OR FABRICATION OR INSTALLATION METHOD TO BE REPLACED. INCLUDE PRODUCT, MATERIAL
OR SYSTEM NAME AND AFFECTED DRAWING NUMBERS AND TITLES.
D. EXECUTE ACCEPTED SUBSTITUTIONS UNDER THE SAME CONDITIONS AS OTHER WORK OF THE CONTRACT.
E. DOCUMENTATION: SHOW COMPLIANCE WITH REQUIREMENTS FOR SUBSTITUTIONS AND THE FOLLOWING, AS APPLICABLE:
1. COST INFORMATION, INCLUDING A PROPOSAL OF CHANGE, IF ANY, IN THE CONTRACT SUM.
2. CONTRACTOR'S CERTIFICATION THAT PROPOSED SUBSTITUTION COMPLIES WITH REQUIREMENTS IN THE CONTRACT DOCUMENTS, EXCEPT AS INDICATED IN SUBSTITUTION REQUEST, IS COMPATIBLE WITH RELATED MATERIALS AND IS APPROPRIATE FOR APPLICATIONS INDICATED.
3. STATEMENT INDICATING WHY SPECIFIED PRODUCT OR FABRICATION, OR INSTALLATION METHOD CANNOT BE PROVIDED, IF APPLICABLE.
4. COORDINATION OF INFORMATION, INCLUDING A LIST OF CHANGES OR REVISIONS NEEDED TO OTHER PARTS OF THE WORK AND TO CONSTRUCTION PERFORMED BY OWNER AND SEPARATE CONTRACTORS THAT WILL BE NECESSARY TO ACCOMMODATE PROPOSED SUBSTITUTION.
5. PRODUCT DATA, INCLUDING DRAWINGS AND DESCRIPTIONS OF PRODUCTS AND FABRICATION AND INSTALLATION PROCEDURES. INCLUDE DETAILED COMPARISON OF SIGNIFICANT QUALITIES OF PROPOSED SUBSTITUTIONS WITH THOSE OF THE WORK SPECIFIED. SIGNIFICANT QUALITIES MAY INCLUDE ATTRIBUTES, SUCH AS PERFORMANCE, WEIGHT, SIZE, DURABILITY, VISUAL EFFECT, SUSTAINABLE DESIGN CHARACTERISTICS, WARRANTIES, AND SPECIFIC FEATURES AND REQUIREMENTS INDICATED. INDICATE DEVIATIONS, IF ANY, FROM THE WORK SPECIFIED
6. CONTRACTOR'S WAIVER OF RIGHTS TO ADDITIONAL PAYMENT OR TIME THAT MAY SUBSEQUENTLY BECOME NECESSARY BECAUSE OF FAILURE OF
PROPOSED SUBSTITUTION TO PRODUCE INDICATED RESULTS.
F. ARCHITECT'S ACTION: IF NECESSARY, ARCHITECT WILL REQUEST ADDITIONAL INFORMATION OR DOCUMENTATION FOR EVALUATION WITHIN 7 DAYS OF RECEIPT OF A REQUEST FOR SUBSTITUTION. ARCHITECT WILL NOTIFY CONTRACTOR OF ACCEPTANCE OR REJECTION OF PROPOSED SUBSTITUTION WITHIN 14 DAYS OF RECEIPT OF REQUEST, OR 7 DAYS OF RECEIPT OF ADDITIONAL INFORMATION OR DOCUMENTATION.
G. ARCHITECT WILL CONSIDER CONTRACTOR'S REQUEST FOR SUBSTITUTION WHEN THE LISTED REQUIREMENTS ARE SATISFIED. IF THE LISTED REQUIREMENTS ARE NOT SATISFIED, ARCHITECT WILL RETURN REQUESTS WITHOUT ACTION, EXCEPT TO RECORD NONCOMPLIANCE WITH LISTED
REQUIREMENTS.
H. FORMS OF ACCEPTANCE: CHANGE ORDER, CONSTRUCTION CHANGE DIRECTIVE, OR ARCHITECT'S SUPPLEMENTAL INSTRUCTIONS FOR MINOR CHANGES IN
THE WORK.
SUBMITTAL REQUIREMENTS:
A. PREPARE SUBMITTAL SCHEDULE: SUBMIT, AS AN ACTION SUBMITTAL, A LIST OF SUBMITTALS, ARRANGED IN CHRONOLOGICAL ORDER BY DATES REQUIRED BY CONSTRUCTION SCHEDULE. INCLUDE TIME REQUIRED FOR REVIEW, ORDERING, MANUFACTURING, FABRICATION, AND DELIVERY WHEN ESTABLISHING DATES. INCLUDE ADDITIONAL TIME REQUIRED FOR MAKING CORRECTIONS OR REVISIONS TO SUBMITTALS NOTED BY ARCHITECT AND CONTRACTOR OR CONSTRUCTION MANAGER AND ADDITIONAL TIME FOR HANDLING AND REVIEWING SUBMITTALS REQUIRED BY THOSE CORRECTIONS.
B. PREPARE AND SUBMIT SUBMITTALS AS INCLUDED IN THE SUBMITTAL SCHEDULE.
C. EMAIL: PREPARE SUBMITTALS AS PDF PACKAGE AND TRANSMIT TO ARCHITECT BY SENDING VIA EMAIL. INCLUDE PDF TRANSMITTAL FORM.
D. WEB-BASED PROJECT MANAGEMENT SOFTWARE: PREPARE SUBMITTALS IN PDF FORM, AND UPLOAD TO WEB-BASED PROJECT MANAGEMENT SOFTWARE WEBSITE. ENTER REQUIRED DATA IN WEB-BASED SOFTWARE SITE TO FULLY IDENTIFY SUBMITTAL.
E. ACTION SUBMITTALS AND INFORMATIONAL SUBMITTALS: REVIEW EACH SUBMITTAL AND CHECK FOR COORDINATION WITH OTHER WORK OF THE CONTRACT AND FOR COMPLIANCE WITH THE CONTRACT DOCUMENTS. NOTE CORRECTIONS AND FIELD DIMENSIONS. MARK WITH APPROVAL STAMP
BEFORE SUBMITTING TO ARCHITECT.
F. USE FOR CONSTRUCTION: RETAIN COMPLETE COPIES OF SUBMITTALS ON PROJECT SITE. USE ONLY FINAL ACTION SUBMITTALS THAT ARE MARKED WITH
NOTATION FROM ARCHITECT'S AND CONTRACTOR’S ACTION STAMP.
G. SUBMITTAL INFORMATION: INCLUDE THE FOLLOWING INFORMATION IN EACH SUBMITTAL:
1. PROJECT NAME, DATE AND INDICATION OF FULL OR PARTIAL SUBMITTAL.
2. ARCHITECT’S AND CONTRACTOR’S AND/OR CONSTRUCTION MANAGER’S, FIRM OR ENTITY THAT PREPARED SUBMITTAL AND SUBCONTRACTOR, MANUFACTURER, AND SUPPLIER NAMES.
3. NUMBER AND TITLE OF SPECIFICATION SECTION, WITH PARAGRAPH NUMBER AND GENERIC NAME FOR EACH OF MULTIPLE ITEMS
4. MATERIAL OR SYSTEM NAME AND DRAWING NUMBER AND DETAIL REFERENCES, AS APPROPRIATE.
5. IDENTIFY OPTIONS REQUIRING SELECTION BY ARCHITECT.
6. LOCATION(S) WHERE PRODUCT IS TO BE INSTALLED, AS APPROPRIATE AND OTHER NECESSARY INFORMATION.
7. ON EACH SUBMITTAL, CLEARLY INDICATE DEVIATIONS FROM REQUIREMENTS IN THE CONTRACT DOCUMENTS, INCLUDING MINOR VARIATIONS AND LIMITATIONS; INCLUDE RELEVANT ADDITIONAL INFORMATION AND REVISIONS, OTHER THAN THOSE REQUESTED BY ARCHITECT AND CONTRACTOR ON PREVIOUS SUBMITTALS. INDICATE BY HIGHLIGHTING ON EACH SUBMITTAL OR NOTING ON ATTACHED SEPARATE SHEET.
H. INCOMPLETE SUBMITTALS ARE UNACCEPTABLE, WILL BE CONSIDERED NONRESPONSIVE, AND WILL BE RETURNED FOR RESUBMITTAL WITHOUT REVIEW.
I. ARCHITECT'S ACTION: ARCHITECT WILL REVIEW INFORMATION OR DOCUMENTATION NOTIFY CONTRACTOR OF ACCEPTANCE REQUEST FOR MORE INFORMATION OR REJECTION WITHIN 14 DAYS OF RECEIPT. ARCHITECT WILL REVIEW RESUBMITTAL WITHIN 14 DAYS OF RECEIPT.
J. SUBMITTALS NOT REQUIRED BY THE CONTRACT DOCUMENTS WILL BE RETURNED BY ARCHITECT WITHOUT ACTION.
Colliers Engineering & Design, Architecture, Landscape Architecture, Surveying, CT P.C.
Colliers
Engineering & Design
Colliers
Engineering & Design
GRAND RAPIDS
560 5th St. NW
Suite 305
Grand Rapids, MI 49504
Phone: 616.827.4270
A R
C H
D x
PROJECT MANAGER:
DESIGNER: REVIEWER:
DISCIPLINE LEAD:
DRAWING NUMBER:
DATE ISSUED: PROJECT NUMBER:
SHEET NAME:
Copyright © 2024. Colliers Engineering & Design All Rights Reserved. This drawing and all the information contained herein is authorized for use only by the party for whom the services were contracted or to whom it is certified. This drawing may not be copied, reused, disclosed, distributed or relied upon for any other purpose without the express written consent of
Colliers Engineering & Design.
www.colliersengineering.com
NOTE: DO NOT SCALE DRAWING FOR CONSTRUCTION.
MI ARCHITECTURE
FIRM LICENSE # NLP000605
BID PACK 2
/1
/2
:4 :4
P
M
EBERSOLE CENTER FOOD
SERVICE - EQUIPMENT
REPLACEMENT &
RENOVATIONS SO-1853
3400 2ND STREET
WAYLAND, MI 49348
C NORRIS
E POST
B HUYLER
A002
GENERAL
REQUIREMENTS
LANSING SCHOOL
DISTRICT
03/13/26 26000750A
DISHWASHING
SERVING
MULTI-PORPOSE
ROOM
STORAGE
DEMO MOVEABLE
PARTITION AND TRACK IN
BULKHEAD ABOVE.
BULKHEAD TO REMAIN
COORDINATE REMOVAL OF
FOOD SERVICE EQUIPMENT
WITH FOOD SERVICE
DRAWINGS
COOLER/FREEZER
TO REMAIN
ROLLING
SHUTTER TO
REMAIN
EXIST
EQUIPMENT
TO REMAIN
(LIGHT GRAY)
1A
1A
DISCONNECT AND REMOVE
EXISTING EQUIPMENT PER
FOOD SERVICE PLANS
DISCONNECT AND REMOVE
EXISTING EQUIPMENT PER
FOOD SERVICE PLANS
CEILING FANS TO REMAIN, TYP
REMOVE SURFACE
MOUNTED LIGHT
FIXTURES, REFER TO
ELECTRICAL
REMOVE TRACK LIGHT
FIXTURES, REFER TO
ELECTRICAL
COMPLETELY REMOVE
PARTITION TRACK. BULKHEAD
TO REMAIN
COMPLETELY REMOVE
PARTITION TRACK. BULKHEAD
TO REMAIN
REMOVE SURFACE
MOUNTED LIGHT
FIXTURES, REFER TO
ELECTRICAL
REMOVE SURFACE
MOUNTED LIGHT
FIXTURES, REFER TO
ELECTRICAL
EXIST RANGE
VENT HOOD TO
REMAIN.
REMOVE FIRE
SUPPRESSION
HEADS
EXIST CEILING
TO REMAIN, TYP
HEATER TO REMAIN
A101
A. CONTRACTOR SHALL COORDINATE REMOVAL OF FLOORS, WALLS
AND CEILINGS WITH MECHANICAL, ELECTRICAL AND PLUMBING
TRADES. ALL POWER, MECHANICAL AND PLUMBING LINES SHALL BE
REMOVED BACK TO NEAREST MAIN BRANCH LINE OR PANEL.
B. CONTRACTOR SHALL PROTECT EXISTING CONSTRUCTION AND
EQUIPMENT NOTED TO REMAIN FROM DAMAGE RESULTING FROM
DEMOLITION ACTIVITIES. ANY DAMAGE TO EXISTING PROPERTY
RESULTING FROM DEMOLITION SHALL BE REPAIRED IMMEDIATELY AT
THE CONTRACTOR'S EXPENSE.
C. CONTRACTOR SHALL PROTECT ADJACENT SURFACES IN
PREPARATION OF SAW CUTTING REQUIRED FOR DEMOLITION
ACTIVITIES.
GENERAL DEMOLITION NOTES
Colliers Engineering & Design, Architecture, Landscape Architecture, Surveying, CT P.C.
Colliers
Engineering & Design
Colliers
Engineering & Design
GRAND RAPIDS
560 5th St. NW
Suite 305
Grand Rapids, MI 49504
Phone: 616.827.4270
A R
C H
D x
PROJECT MANAGER:
DESIGNER: REVIEWER:
DISCIPLINE LEAD:
DRAWING NUMBER:
DATE ISSUED: PROJECT NUMBER:
SHEET NAME:
Copyright © 2024. Colliers Engineering & Design All Rights Reserved. This drawing and all the information contained herein is authorized for use only by the party for whom the services were contracted or to whom it is certified. This drawing may not be copied, reused, disclosed, distributed or relied upon for any other purpose without the express written consent of
Colliers Engineering & Design.
www.colliersengineering.com
NOTE: DO NOT SCALE DRAWING FOR CONSTRUCTION.
MI ARCHITECTURE
FIRM LICENSE # NLP000605
BID PACK 2
/1
/2
:4 :4
P
M
EBERSOLE CENTER FOOD
SERVICE - EQUIPMENT
REPLACEMENT &
RENOVATIONS SO-1853
3400 2ND STREET
WAYLAND, MI 49348
C NORRIS
E POST
B HUYLER
AD101
FIRST FLOOR
DEMOLITION PLAN
LANSING SCHOOL
DISTRICT
03/13/26 26000750A
SCALE : 1/8" = 1'-0"
FIRST FLOOR DEMOLITION PLAN
SCALE : 1/8" = 1'-0"
FIRST FLOOR REFLECTED CEILING DEMOLITION PLAN
N
1A SAWCUT EXISTING MOSAIC CERAMIC TILE AND SLAB AS REQ'D FOR
MEP. COORDINATE LOCATIONS WITH MEP & FS DRAWINGS.
DEMO PLAN KEYNOTES #
1009A
WALK-IN
COOLER
1009B
WALK-IN
FREEZER
MULTI-PORPOSE
ROOM
KITCHEN
SERVING
DISHWASHING
STORAGE
WC
COORDINATE ALL NEW
EQUIPMENT WITH FOOD
SERVICE AND MEP
DRAWINGS
V
IF
EXIST BULKHEAD ABOVE
EXIST BULKHEAD ABOVE
COORDINATE ALL NEW
EQUIPMENT WITH FOOD
SERVICE AND MEP
DRAWINGS
EXIST
EQUIPMENT TO
REMAIN (LIGHT
GRAY)
A1
A1
A2 A2
A2
A2
A3
A4
A5
A4
A3
A101
A101
Sim
A101
Sim
A101
Sim
REMOVE EXISTING TRACK
AND WOOD TRIM. WRAP
COLUMN WITH NEW 1x
POPULAR TRIM AND PAINT.
COORDINATE
NEW EQUIPMENT
WITH EXISTING
VENTING TO
ROOF
NEW SURFACE
MOUNTED LIGHT
FIXTURES. REFER TO
ELECTRICAL DWGS
A101
C1
C2C2
C1
C3
C4
C4
C4
NEW SURFACE
MOUNTED LIGHT
FIXTURES. REFER TO
ELECTRICAL DWGS
CEILING LEGEND
NOTE: SEE OTHER DISCIPLINE DRAWINGS (E.G. MECHANICAL, PLUMBING
AND ELECTRICAL DRAWINGS) FOR ASSOCIATED SYSTEMS AND
INFORMATION ABOUT SYMBOLS NOT INDICATED IN THIS LEGEND.
4' x 8' TECTUM CEILING
GYPSUM BOARD CEILING/SOFFIT
OPEN TO DECK
REMOVE PARTITION
AND WOOD TRIM,
ENTIRE EXTENT OF
BULKHEAD EA SIDE
8' - 7 3/4"
B.O. TRIM VIF
(B.O. TRIM
7'-11 1/4" AT
SERVING, VIF)
REPLACE TRIM W/ NEW
NOMINAL 1x10 CONTINUOUS
POPULAR WOOD TRIM,
PAINTED
PROPOSED CONDUIT
LOCATION, REFER TO
ELEC. DWGS
NEW PAINTED TRIM AT
JAMB, BEYOND
A
REMOVE PARTITION
TRACK FROM WALL
AND EXISTING WOOD
JAMB TRIM, EA SIDE
PROVIDE NEW NOMINAL
1x10 CONTINUOUS POPULAR
WOOD , PAINTED.
TRIM AT JAMB TO BE FLUSH
WITH TRIM AT HEAD
SCALE : 1/8" = 1'-0"
FIRST FLOOR PLAN
SCALE : 1/8" = 1'-0"
FIRST FLOOR REFLECTED CEILING PLAN
Colliers Engineering & Design, Architecture, Landscape Architecture, Surveying, CT P.C.
Colliers
Engineering & Design
Colliers
Engineering & Design
GRAND RAPIDS
560 5th St. NW
Suite 305
Grand Rapids, MI 49504
Phone: 616.827.4270
A R
C H
D x
PROJECT MANAGER:
DESIGNER: REVIEWER:
DISCIPLINE LEAD:
DRAWING NUMBER:
DATE ISSUED: PROJECT NUMBER:
SHEET NAME:
Copyright © 2024. Colliers Engineering & Design All Rights Reserved. This drawing and all the information contained herein is authorized for use only by the party for whom the services were contracted or to whom it is certified. This drawing may not be copied, reused, disclosed, distributed or relied upon for any other purpose without the express written consent of
Colliers Engineering & Design.
www.colliersengineering.com
NOTE: DO NOT SCALE DRAWING FOR CONSTRUCTION.
MI ARCHITECTURE
FIRM LICENSE # NLP000605
BID PACK 2
/1
/2
:4 :4
P
M
EBERSOLE CENTER FOOD
SERVICE - EQUIPMENT
REPLACEMENT &
RENOVATIONS SO-1853
3400 2ND STREET
WAYLAND, MI 49348
C NORRIS
E POST
B HUYLER
A101
FIRST FLOOR AND
CEILING PLANS
LANSING SCHOOL
DISTRICT
03/13/26 26000750A
N
SCALE : 1" = 1'-0"
PARTITION HEAD DTL
CEILING PLAN KEYNOTES #
C1 EXISTING CEILING TO REMAIN. PAINT TOUCH UP AS REQUIRED FOR
NEW LIGHT INSTALLATION.
C2 EXISTING TECTUM CEILING TO REMAIN. PAINT TOUCH UP AS
REQUIRED FOR NEW LIGHT INSTALLATION.
C3 EXISTING PLASTERED CEILING TO REMAIN. PATCH AND REPAIR
WATER DAMAGE AREAS AND PAINT ENTIRE CEILING.
C4 EXISTING PLASTERED CEILING TO REMAIN. PATCH AS REQUIRED
AND PAINT TOUCH UP AS REQUIRED FOR NEW LIGHT
INSTALLATION.
FLOOR PLAN KEYNOTES #
A1 EXISTING VCT FLOORING TO REMAIN. NO WORK ANTICIPATED.
A2 BULKHEAD AT FOLDING PARTITIONS TO BE PAINTED BOTH SIDES IN
ITS ENTIRETY. ALL OTHER WALLS TO REMAIN AS IS.
A3 EXISTING MOSAIC FLOOR TILING TO REMAIN. PATCH AS REQUIRED
FOR NEW POWER, DRAINS AND WATER LINES.
A4 PROVIDE PAINT TOUCH UP WHERE EQUIPMENT IS BEING REMOVED.
A5 EXISTING EXPOSED CONCRETE FLOORING TO REMAIN.
REV DATE DESCRIPTION
3 03/13/26 BID PACK 2 - BIDS &PERMITS
SCALE : 1" = 1'-0"
PARTITION JAMB DTL
DISHWASHING
SERVING
MULTI-PORPOSE
ROOM
STORAGE
PD101
FIRST FLOOR PLAN -
DEMOLITION
1/
/2
4:
:5
P
M
EBERSOLE CENTER FOOD
SERVICE - EQUIPMENT
REPLACEMENT &
3400 2ND STREET
WAYLAND, MI 49348
26000750A
REV DATE DESCRIPTION
Colliers Engineering & Design, Architecture, Landscape Architecture, Surveying, CT P.C.
Colliers
Engineering & Design
Colliers
Engineering & Design
GRAND RAPIDS
560 5th St. NW
Suite 305 Grand Rapids, MI 49504
Phone: 616.827.4270
PROJECT MANAGER:
DESIGNER: REVIEWER:
DISCIPLINE LEAD:
DRAWING NUMBER:
DATE ISSUED: PROJECT NUMBER:
SHEET NAME:
www.colliersengineering.com
NOTE: DO NOT SCALE DRAWING FOR CONSTRUCTION.
MI ARCHITECTURE
FIRM LICENSE # NLP000605
Copyright © 2024. Colliers Engineering & Design All Rights Reserved. This drawing and all the information contained herein is authorized for use only by the party for whom the services were contracted or to whom it is certified. This drawing may not be copied, reused, disclosed, distributed or relied upon for any other purpose without the express written consent of Colliers Engineering & Design.
BID PACK 2
DATE DESCRIPTION
100 Cesar E Chavez Ave SW Grand Rapids, Michigan 49503
(616) 742-2810 www.classicengineering.com Project # 2026021
Classic Engineering, LLC
03/16/2026
1 03/16/26 BID PACK 2 - BIDS & PERMITS
LANSING SCHOOL
DISTRICT
RENOVATIONS SO-1853
SCALE: 1/8" = 1'-0"
L WOOD L WOOD
J FEISTRITZER L WOOD
03.13.26
LANSING SCHOOL
DISTRICT
BID PACK 2
EBERSOLE CENTER FOOD
SERVICE - EQUIPMENT
REPLACEMENT &
RENOVATIONS SO-1853
3400 2ND STREET
WAYLAND, MI 49348
COOLER
1009B
WALK-IN
FREEZER
MULTI-PORPOSE
ROOM
KITCHEN
SERVING
DISHWASHING
STORAGE
WC
P101
FIRST FLOOR PLAN -
PLUMBING
1/
/2
4:
:5
P
M
EBERSOLE CENTER FOOD
SERVICE - EQUIPMENT
REPLACEMENT &
3400 2ND STREET
WAYLAND, MI 49348
26000750A
REV DATE DESCRIPTION
Colliers Engineering & Design, Architecture, Landscape Architecture, Surveying, CT P.C.
Colliers
Engineering & Design
Colliers
Engineering & Design
GRAND RAPIDS
560 5th St. NW
Suite 305 Grand Rapids, MI 49504
Phone: 616.827.4270
PROJECT MANAGER:
DESIGNER: REVIEWER:
DISCIPLINE LEAD:
DRAWING NUMBER:
DATE ISSUED: PROJECT NUMBER:
SHEET NAME:
www.colliersengineering.com
NOTE: DO NOT SCALE DRAWING FOR CONSTRUCTION.
MI ARCHITECTURE
FIRM LICENSE # NLP000605
Copyright © 2024. Colliers Engineering & Design All Rights Reserved. This drawing and all the information contained herein is authorized for use only by the party for whom the services were contracted or to whom it is certified. This drawing may not be copied, reused, disclosed, distributed or relied upon for any other purpose without the express written consent of Colliers Engineering & Design.
BID PACK 2
DATE DESCRIPTION
100 Cesar E Chavez Ave SW Grand Rapids, Michigan 49503
(616) 742-2810 www.classicengineering.com Project # 2026021
Classic Engineering, LLC
03/16/2026
1 03/16/26 BID PACK 2 - BIDS & PERMITS
LANSING SCHOOL
DISTRICT
RENOVATIONS SO-1853
SCALE: 1/8" = 1'-0"
L WOOD L WOOD
J FEISTRITZER L WOOD
03.13.26
LANSING SCHOOL
DISTRICT
BID PACK 2
EBERSOLE CENTER FOOD
SERVICE - EQUIPMENT
REPLACEMENT &
RENOVATIONS SO-1853
SYMBOL NOTES:
1. "AC" DENOTES ABOVE COUNTER. COORDINATE HEIGHT WITH ARCHITECT.
2. "H" DENOTES HORIZONTAL MOUNTING OF DEVICE.
3. "B" DENOTES MOUNTED IN BASE.
4. "F" DENOTES MOUNTED IN FACE OF CABINETS.
D
S
SECURITY INTERCOM
SECURITY DOOR CONTACT
CEILING SPEAKER
AUDIO ONLY ALARM
VISUAL ONLY ALARM
FIRE ALARM CONTROL RELAY
REMOTE ALARM KEY TEST SWITCH
WATER FLOW SWITCH
O,S,&Y TAMPER SWITCH
HEAT DETECTOR
DUCT SMOKE DETECTOR
AREA SMOKE DETECTOR-PHOTOELECTRIC
FIRE ALARM PULL STATION
CEILING SPEAKER
SPEAKER/STROBE LIGHT
LMTG. HT. TO CDESCRIPTIONSYMBOL
SYSTEMS SYMBOL LEGEND
FIRE ALARM ANNUNCIATOR PANEL
FIRE ALARM CONTROL PANEL
F
CO
CR
FS
D
TS
RT
F.A.A.
F.A.C.P.
F.A. NOTES:
1. MATCH EXISTING SYSTEM.
SECURITY DOOR REQUEST TO EXIT
CO
R CARD READER
MAGNETIC DOOR HOLD OPENDH
CARBON MONOXIDE SENSOR. E.C TO ROUGH-IN SINGLE
GANG BOX AND 1/2"C. TO ACCESSIBLE CEILING SPACE.
46"
80"
80"
46"
46"
AT DOOR HEAD
46"
AT DOOR HEAD
TYPICALLY CLG
MOUNTED
SMOKE/HORN BASE
CO-DENOTES COMBO CARBON MONOXIDE/SMOKE
I
C
X
H
FIRE/SMOKE DAMPER
BEAM DETECTOR
F/SD
BD ---
SECURITY CAMERA - "W" DENOTES WALL MOUNTED
CHEVRON INDICATES AIM LINE
WP FIRE ALARM HORN/STROBE LIGHT
(WP-DENOTES WEATHER PROOF)
T THERMOSTAT. E.C TO ROUGH-IN SINGLE GANG BOX AND
1/2"C. TO ACCESSIBLE CEILING SPACE.
TRANSFORMER
SURFACE OR FLUSH MTD. BRANCH CIRCUIT PANELBOARD
THREE PHASE ELECTRIC MOTOR
SINGLE PHASE ELECTRIC MOTOR
MAGNETIC MOTOR STARTER-MS
DIMMER SWITCH
46"
KEY OPERATED SWITCH-SPEC. GRADE
FOUR WAY SWITCH-SPEC. GRADE
T
F
P
F
J
ELECTRICAL SYMBOL LEGEND
S
S
S
WR
D
K
S
SYMBOL DESCRIPTION
MTG. HT. TO CL
SPECIAL OUTLET-CHARACTERISTICS AS NOTED ON PLANS
FLOOR BOX 1 RECEPT, 1 DATA - THOMAS & BETTS-# 664-SC
1-1/4"C TO FLOORBOX FOR DATA
FLOOR BOX 2 RECEPT, 2 DATA THOMAS & BETTS-# 665-SC
1-1/4"C TO FLOORBOX FOR DATA
OS
IRDS IR SWITCH DIMMABLE
OCCUPANCY SENSOR
PUSH BUTTONPB
TV
IRS IR SWITCH
CS CONTROL STATION
C
SPECIAL SINGLE RECEPTACLE
VARIABLE FREQUENCY DRIVEVFD
PC PHOTO CELL
46"
46"
46"
46"
46"
46"
18"
18"
18"
18"
18"
AS NOTED
18"
46"
46"
46"
AT EQUIP.
AS NOTED
AS NOTED
46"
46"
46"
46"
72" TO TOP
18"
SINGLE POLE OR 3-WAY SWITCH-
SPECIFICATION GRADE
SPLIT WIRED RECEPTACLE
C - DENOTES CONTROLLED VIA RELAY OR OCC SENSOR
WATER RESISTANT GROUND FAULT CIRCUIT INTERRUPTER
WR-DENOTES WEATHERPROOF WHILE IN USE COVER
DUPLEX OUTLET-SPEC. GRADE
CIRCLE AROUND SYMBOL= CEILING MOUNTED
DATA OUTLET-4" SQ. BOX W/ 1 GANG RAISED COVER.
1-1/4"C. UP WALL TO CLG. SPACE
CIRCLE AROUND SYMBOL= CEILING MOUNTED
TV OUTLET-4" SQ. BOX W/ 1 GANG RAISED COVER.
1-1/4"C. UP WALL TO CLG. SPACE
CIRCLE AROUND SYMBOL= CEILING MOUNTED
JUNCTION BOX - HUBBELL NSAV62M WITH RECEPTACLE KIT
HUBBELL NSOKP. PROVIDE CONNECTOR PLATE FOR A/V
JUNCTION BOX -4" SQ. BOX W/ 2 GANG RAISED COVER.
1"C. UP WALL TO CLG. SPACE UNLESS OTHERWISE NOTED
FUSED DISCONNECT SWITCH-
FDS-HEAVY DUTY
NON-FUSED DISCONNECT SWITCH-
NFDS-HEAVY DUTY
SW. AND PLUGFUSE HOLDER- BUSSMANN
"SSU" & FUSESTAT FUSE
COMBINATION MAG. STARTER/ FUSED DISC. SWITCH - CS/FDS
COMBINATION MAG. STARTER/NON-FUSED DISC.
SWITCH - CS/NFDS
(2) DUPLEX OUTLET-SPEC. GRADE
CIRCLE AROUND SYMBOL= CEILING MOUNTED
S
PARTIALLY SHADED LUMINAIRE OR WITH "E" SUFFIX ARE
EMERGENCY
BATTERY EMERGENCY LUMINAIRE
REMOTE EMERGENCY HEAD
RECESSED LUMINAIRE 2'x4' OR 2'x2'
RECESSED WALLWASH LUMINAIRE
RECESSED DOWNLIGHT LUMINAIRE
LED ACCENT/UNDER CABINET LUMINAIRE
TRACK LIGHTING LUMINAIRE
SURFACE LUMINAIRE
WALL MOUNTED LUMINAIRE
PENDANT LUMINAIRE
SITE LIGHTING LUMINAIRE
NIGHT LIGHT
STRIP LUMINAIRE
SURFACE LUMINAIRE 2'x4' OR 2'x2'
EXIT SIGN - WALL MOUNTED OR CEILING MOUNTED
ARROWS INDICATE PATH OF EGRESS
NL
EE
H HUMIDISTAT. E.C TO ROUGH-IN SINGLE GANG BOX AND
1/2"C. TO ACCESSIBLE CEILING SPACE. 46"
WN ---
PS SWITCH WITH PILOT LIGHT 46"
18"TELEPHONE OUTLET-4" SQ. BOX W/ 1 GANG RAISED
COVER. 1-1/4"C. UP WALL TO CLG. SPACE
18"TELEPHONE/DATA OUTLET-4" SQ. BOX W/ 1 GANG
RAISED COVER. 1-1/4"C. UP WALL TO CLG. SPACE
M ---ELECTRIC UTILITY METER
P ---POWER POLE - SEE DRAWING FOR POWER -
POWER/DATA SPECIFICATIONS
DS DAYLIGHT SENSOR ---
MS MANUAL MOTOR STARTER SWITCH 46"
ELECTRICAL IDENTIFICATION
N.T.S.
FRONT
REAR SIDE
OF PLATE
FRONT
REAR SIDE OF
PLATE
BPA-15LP2-5
LABEL CKT. NO. OF EACH DEVICE ON REAR
SIDE OF COVER PLATE. USE PERMANENT
MARKER PEN, BRADY MARKING SYSTEM OR
OTHER METHOD APPROVED BY THE ENGINEER
JUNCTION BOXES (EXPOSED
OR CONCEALED ABOVE
ACCESSIBLE CEILING)
LABEL COVERS WITH…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .