Summary: LSD Attwood Cafeteria and Kitchen Renovations - Addendum 1

This document is an addendum issued by Colliers Engineering & Design on behalf of the Lansing School District (LSD) for the Attwood Cafeteria and Kitchen Renovations project located at 915 Attwood Drive, Lansing, Michigan 48911 (Project SO-1851, Architect's Project #26000747A). Addendum No. 1, issued April 3, 2026, modifies the contract documents and specifications for interior renovations of the existing Multi-Purpose Room (A-108) and adjacent Kitchen Storage (Room 91), consisting of paint, acoustic treatment, and casework work. The addendum introduces two voluntary alternates: Alternate 1A provides a deduct option to remove all scope in Kitchen Prep Room 91 including demolition, electrical, plumbing, casework, and finishes; Alternate 2A offers an alternate price to prep Multi-Purpose walls by removing loose and peeling paint, sanding, and applying primer rather than removing all paint to bare substrate. The addendum revises multiple drawings (G000, A101, A141) and introduces new electrical drawings (E100, EL101, EL102, EP101). The project is designed according to the 2021 Michigan Building Code, 2021 Michigan Rehabilitation Code, NFPA 101, and 2023 Michigan Electrical Code. The existing 45,300-square-foot building is non-combustible and non-sprinklered, with a 2,292-square-foot renovation area classified for educational use.

The project specifications include Sherwin Williams paint systems with varying finishes (eggshell, semi-gloss, and flat) for different applications including Tectum acoustic panels, steel decking, and wall surfaces. Tectum high-NRC direct-attach wall panels will be installed with 3/4-inch furring strips at 24-inch on-center spacing, with panels to be painted before installation as accent colors. Casework includes plastic-laminate-clad architectural cabinets to Custom Grade specifications, stainless steel countertops with 4-inch backsplash, and new shelving. Electrical work involves new lighting (general and emergency), power distribution, and GFCI receptacles. The addendum includes photographs documenting existing peeling paint conditions in the Multi-Purpose Room and results of cross-cut adhesion testing with Sherwin Williams Extreme Bond Primer. Contract administration is led by Courtney Norris (Colliers Engineering & Design), with David Beckering as the contractor contact (Beckering Construction, Grand Rapids, Michigan). Supporting clarifications address paint specifications, tectum panel installation, and flooring prep work requirements including a $5,000.00 allowance for nonstandard prep work tracking with time-and-material documentation.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

LSD Attwood Cafeteria and Kitchen Renovations – Addendum 1 Page 1 | 3

LSD Attwood Cafeteria and Kitchen Renovations Addendum No. 1 Narrative of Changes

Project Name: Attwood Cafeteria and Kitchen Renovations

SO-1851

Date: April 3, 2026

Project Location:

915 Attwood Dr, Lansing, MI 48911

Architect’s Project #: 26000747A

Owner/Client: Lansing School District Attention: David Beckering

Issued to: Beckering Construction Email: djb@beckering.com City/State: Grand Rapids, MI Zip: 49548

Delivered via:

This Addendum revises the Contract Documents and shall have the same force and effect;

make the following changes to the Specifications and Drawings for this project. The following is a written summary of the changes made by this Addendum. Strict attention should be given to the Drawings and Specifications for area take-off, quantities and items deleted or revised herein. This addendum forms a part of the Contract Documents.

Issued by CED by: Courtney Norris Date Signed: 04/03/2026 Prepared by: Courtney Norris Date Signed: 04/03/2026 Distribution:

Below is a list of the changes made to our documents in response to the comments, RFIs, or clarifications provided prior to Bid. Please feel free to reach out with any further questions or clarifications in a timely manner.

Sincerely, Courtney Norris

☐ Messenger

☐ Express

☐ Mail

☐ Hand-carried

☐ Pick-up

☐ UPS

Address Sent to:

☐ Newforma

☒ Email

☐ FTP

LSD Attwood Cafeteria and Kitchen Renovations – Addendum 1 Page 2 | 3

General Notes/ Clarifications

• Alternate 1A: Provide a deduct alternate to remove scope in Kitchen Prep 91. This includes all demo, electrical, plumbing, casework and finishes in this room. Deduct should be provided in the voluntary alternate section of the Bid Form.

• Alternate 2A: Provide an alternate price to prep Multi-Purpose walls before paint by removing all loose and peeling paint, providing an abrasive sanding and then washing the walls with a cleaner/ degreaser before applying the extreme bond primer. Base bid is to remove all paint to bare substrate with blasting or chemical peel. Alternate to be provided in the voluntary alternate section of the Bid Form.

• See attached images of existing walls in the Multi-Purpose Room A-108 depicting the state of the peeling paint.

Drawings

• G000 – COVER Sheet (Reissued) o Added electrical sheets to sheet list

• A101 – FIRST FLOOR PLAN AND ELEVATIONS (Reissued) o Added paint designation on tectum panels in elevation

• A141 – FIRST FLOOR FINISH PLAN (Reissued) o Revised painting specification to include paint system for tectum panels.

o Revised steel decking paint specification to indicate flat finish.

o Updated paint basis of design.

o Revised color of tectum panels.

• E100 – ELECTRICAL SYMBOLS AND SPECIFICATOINS

o New sheet

• EL101 – FIRST FLOOR PLAN – LIGHTING

• EL102 – FIRST FLOOR PLAN – EMERGENCY LIGHTING

• EP101 – FIRST FLOOR PLAN – POWER

LSD Attwood Cafeteria and Kitchen Renovations – Addendum 1 Page 3 | 3

ATTACHMENTS

LSD Attwood Cafeteria and Kitchen Renovations – Multi-purpose Room A-108 Photos

Reissued Drawings:

G000, A101, A141

New Drawings:

E100, EL101, EL102, EP101

Clarifications 1, 2, 3

END OF ADDENDUM NO. 1

LSD Attwood Cafeteria and Kitchen Renovations – Multi-Purpose Room A-108 Photos Page 1 | 5

LSD Attwood Cafeteria and Kitchen Renovations Multi-Purpose Room A-108 Photos

04/03/2026

Figure 1: North wall Multi-Purpose Room

LSD Attwood Cafeteria and Kitchen Renovations – Multi-Purpose Room A-108 Photos Page 2 | 5

Figure 2: Peeling paint on East wall Multi-Purpose Room

LSD Attwood Cafeteria and Kitchen Renovations – Multi-Purpose Room A-108 Photos Page 3 | 5

Figure 3: Peeling paint on North wall Multi-Purpose Room

LSD Attwood Cafeteria and Kitchen Renovations – Multi-Purpose Room A-108 Photos Page 4 | 5

Figure 4: East wall Multi-Purpose Room

LSD Attwood Cafeteria and Kitchen Renovations – Multi-Purpose Room A-108 Photos Page 5 | 5

Figure 5: Results from cross-cut adhesion test with SW extreme bond primer.

www.colliersengineering.com

GRAND RAPIDS

560 5th St. NW Suite 305 // Grand Rapids, MI 49504

Phone: 616.827.4270

Colliers Engineering

& Design A

R C

H D x

DRAWING NUMBER:

Copyright © 2025. Colliers Engineering & Design All Rights Reserved. This drawing and all the information contained herein is authorized for use only by the party for whom the services were contracted or to whom it is certified. This drawing may not be copied, reused, disclosed, distributed or relied upon for any other purpose without the express written consent of

Colliers Engineering & Design.

NOTE: DO NOT SCALE DRAWING FOR CONSTRUCTION.

MI ARCHITECTURE

FIRM LICENSE # NLP000605

DRAWING INDEXPROJECT CONTACT LIST

PROJECT LOCATION MAP

OWNER:

LANSING SCHOOL DISTRICT

519 W KALAMAZOO

LANSING, MI

CONTACT: TODD COE

ARCHITECT:

COLLIERS ENGINEERING & DESIGN

560 5TH ST, STE 305

GRAND RAPIDS, MI

CONTACT: COURTNEY NORRIS

PHONE: 616-827-4276

CONTRACTOR:

BECKERING CONSTRUCTION

650 44TH ST SE

GRAND RAPIDS, MI

CONTACT: DAVID BECKERING

ELECTRICAL ENGINEER:

CLASSIC ENGINEERING

100 CESAR E CHAVEZ AVE SW, #400

GRAND RAPIDS, MI

CONTACT: CINDY LADEWIG

MECHANICAL ENGINEER:

CLASSIC ENGINEERING

100 CESAR E CHAVEZ AVE SW, #400

GRAND RAPIDS, MI

CONTACT: LARRY WOOD

/3

/2

:1 :5

P

M

ATTWOOD CAFETERIA AND

KITCHEN RENOVATIONS SO-1851

915 ATTWOOD DR

LANSING, MI 48911

G000

04/03/26

SHEET INDEX

00 - GENERAL

G000 COVER SHEET

G001 CODE COMPLIANCE & LIFE SAFETY PLANS

04 - ARCHITECTURAL

A001 GENERAL NOTES AND LEGENDS

A002 GENERAL REQUIREMENTS

AD101 DEMOLITION PLANS

AD141 DEMOLITION ELEVATIONS

A101 FIRST FLOOR PLAN AND ELEVATIONS

A121 FIRST FLOOR CEILING PLAN

A141 FIRST FLOOR FINISH PLAN

08 - ELECTRICAL

E100 ELECTRICAL SYMBOLS AND SPECIFICATIONS

EL101 FIRST FLOOR PLAN - LIGHTING

EL102 FIRST FLOOR PLAN - EMERGENCY LIGHTING

EP101 FIRST FLOOR PLAN - POWER

PROJECT SCOPE

INTERIOR RENOVATIONS OF EXISTING MULTI-PURPOSE ROOM AND ADJACENT KITCHEN STORAGE; CONSISTING OF

PAINT, ACOUSTIC TREATMENT, AND CASEWORK.

APPLICABLE BUILDING CODES

BUILDING CODE: 2021 MICHIGAN BUILDING CODE

2021 MICHIGAN REHABILITATION CODE - ALTERATION LEVEL ONE

MI FIRE SAFETY

STATE RULES: NFPA 101, 2012

2016 SCHOOL FIRE SAFETY RULES

MECHANICAL CODE: 2021 MICHIGAN MECHANICAL CODE

PLUMBING CODE: 2021 MICHIGAN PLUMBING CODE

ELECTRICAL CODE: 2023 MICHIGAN ELECTRICAL CODE, PART 8 RULES (BY REFERENCE 2023 NEC)

ACCESSIBILITY: BARRIER FREE - ICC A117.1-2017

ENERGY CODE: 2021 MICHIGAN ENERGY CODE

BUILDING DATA

EXISTING BUILDING AREA: 45,300 SF

CONSTRUCTION TYPE= II-B NON-COMBUSTIBLE

NON-SPRINKLERED

RENOVATION AREA: 2,292 SF

USE AND OCCUPANCY

BUILDING IS CLASSIFIED AS "E" EDUCATIONAL

INTERIOR FINISH

SECTION 803 INTERIOR FINISH AND TRIM: NON-SPRINKLERED TABLE 803.11

INTERIOR FINISHES AND TRIM SHALL MEET FLAME SPREAD, SMOKE DEVELOPED AND CLASS RATINGS

AS REQUIRED FOR SPECIFIC USE AND AREA: E

PROJECT LOCATION

S M

LK

J R B

LV

D

S W

A S

H

IN

G T

O N

A V

E

W MILLER RD I-96

I-96

S C

E D

A R

S T

W JOLLY RD

W NORTHRUP ST

REV DATE DESCRIPTION

3 03/13/26 BID PACK 2 - BIDS &PERMITS

4 04/03/26 BID PACK 2 - ADDENDUM 1

3 42

MULTI PURPOSE

A-108

KITCHEN PREP

STORAGE

93S

EAST EGRESS LOBBY

A-125

WEST EGRESS LOBBY

A-122

VEST

A-123

VEST

A-126

CORR

A-80B

CORR

A-80D

CORRIDOR

80A

GYMNASIUM

A-124

A101 4

A101 67

A121

A121

A121

PROPOSED LOCATION FOR

RELOCATED FIRE

EXTINGUISHER.

COORDINATE FINAL

LOCATION WITH OWNER.

A. REFER TO A001 SERIES DRAWINGS FOR SYMBOLS, NOTES, AND

ADDITIONAL CODE INFORMATION.

B. REFER TO AD100 SERIES DRAWINGS FOR DEMOLITION PLANS.

C. REFER TO A120 SERIES DRAWINGS FOR REFLECTED CEILING PLANS

AND DETAILS.

D. REFER TO A140 SERIES DRAWINGS FOR GYM FLOOR STRIPING PLANS

AND GENERAL FINISH NOTES.

E. ADJUST SITE GRADING AS REQ'D TO MEET EXIST SIDEWALK.

CONTRACTOR RESPONSIBLE FOR REPAIRING GRASS AREAS

DISTURBED BY CONSTRUCTION TO LIKE CONDITIONS (NEW TOP SOIL,

REGRADING, AND SEED).

GENERAL NOTES

(2) 4x6 TECTUM

PANELS

PAINT P-7

P-2

12' - 0"

(1) 4x6 TECTUM

PANEL

PAINT P-7

(1) 4x6 TECTUM

PANEL

PAINT P-7

EQEQ EQ EQEQ EQ

SAP-1 SAP-1 SAP-1

P-4

(2) 4x8 TECTUM PANELS

PAINT P-6

(1) 4x8 PANEL, (2) 4x6 PANELS

TECTUM PANELS

PAINT P-6

P-1

6' - 0" 8' - 0" 6' - 0"

SAP-1

SAP-1

P-4

2' - 3 3/4" 20' - 0" 19' - 4" 16' - 0" 1' - 11 1/2"

(1) 4x6 TECTUM

PANEL

PAINT P-7

P-2

(1) 4x6 TECTUM

PANEL

PAINT P-7

(1) 4x6 TECTUM

PANEL

PAINT P-7

EQEQ

EQEQ

EQEQ

SAP-1 SAP-1 SAP-1

P-4

P-2

3 3

A4

A4A4

A4

(3) 4x8 TECTUM PANELS

PAINT P-6

5' - 3 3/4" 24' - 0" 9' - 0 1/2" 20' - 0" 1' - 3"

P-1

(1) 4x8 PANEL, (2) 4x6 PANELS

TECTUM PANELS

PAINT P-6

BASIS OF DESIGN:

TECTUM HIGH NRC DIRECT-ATTACH

WALL PANELS. PROVIDE 3/4" FURRING

STRIPS @ 24" OC PER MANUFACTURE

INSTALLATION REQUIREMENTS.

SAP-1SAP-1

P-4

8' - 8"

2 2

P-4P-1

FILLER

2' - 9" 3' - 0" 3' - 0" 2' - 9"

FILLER

EXTEND COUNTER

UNDER ROLLING DOOR

SS-1 COUNTER TOP

WITH 4" BACKSPLASH

PLAM-1 CASEWORK (2)

INTERNAL ADJUSTABLE

SHELVES EACH

ROLLING DOOR TO REMAIN

A121

WALLS TO BE PAINTED, SEE

FINISH SCHEDULE

V.I.F

5' - 4 1/2" 6' - 6"

FILLER

4' - 0"

RELOCATED

FREEZER &

FRIDGE

REINSTALL HOT

WATER HEATER

INSIDE NEW CABINET

RELOCATED

CLEANING SOLUTION

DISPENSERS

REINSTALL PAPER

TOWEL & SOAP

DISPENSER

(2) NEW 4'-0" STAINLESS

STEEL SHELVES

BASIS OF DESIGN: EAGLE

GROUP WS1248-16/3

REINSTALL EXISTING

SINK & FAUCET INTO

NEW CASEWORK

NEW SS-1 COUNTERTOP

WITH 4" BACKSPLASH

PLAM-1 CASEWORK

A121

A121

WALLS TO

BE PAINTED

Colliers Engineering & Design, Architecture, Landscape Architecture, Surveying, CT P.C.

Colliers

Engineering & Design

Colliers

Engineering & Design

GRAND RAPIDS

560 5th St. NW

Suite 305

Grand Rapids, MI 49504

Phone: 616.827.4270

A R

C H

D x

PROJECT MANAGER:

DESIGNER: REVIEWER:

DISCIPLINE LEAD:

DRAWING NUMBER:

DATE ISSUED: PROJECT NUMBER:

KEY PLAN

SHEET NAME:

Copyright © 2024. Colliers Engineering & Design All Rights Reserved. This drawing and all the information contained herein is authorized for use only by the party for whom the services were contracted or to whom it is certified. This drawing may not be copied, reused, disclosed, distributed or relied upon for any other purpose without the express written consent of

Colliers Engineering & Design.

www.colliersengineering.com

NOTE: DO NOT SCALE DRAWING FOR CONSTRUCTION.

MI ARCHITECTURE

FIRM LICENSE # NLP000605

TRUE NORTHPLAN NORTH

/3

/2

:1 :5

P

M

ATTWOOD CAFETERIA

AND KITCHEN

RENOVATIONS SO-1851

915 ATTWOOD DR

LANSING, MI 48911

C NORRIS

E POST

B HUYLER

A101

FIRST FLOOR PLAN AND

ELEVATIONS

LANSING SCHOOL

DISTRICT

04/03/26 26000747A

SCALE : 1/8" = 1'-0"

FIRST FLOOR PLAN

KEYNOTES #

1 NEW FRAMED TACK BOARD. CONFIRM DIMENSIONS ON SITE.

2 NEW TACK STRIP FULL ELNGTH OF WALL. INSTALLATION AND

HEIGHT TO BE COORDIANATED WITH OWNER.

3 DO NOT PAINT EXISTING MECHANICAL UNITS.

A4 EXISTING STRUCTURAL SUPPORTS TO REMAIN AS IS. MATCH

EXISTING PAINT AS REQUIRED FOR TOUCH UP.

N

SCALE : 1/4" = 1'-0"

INT NORTH ELEV

SCALE : 1/4" = 1'-0"

INT EAST ELEV

SCALE : 1/4" = 1'-0"

INT SOUTH ELEV

SCALE : 1/4" = 1'-0"

INT WEST ELEV

SCALE : 1/4" = 1'-0"

INT KITCH EAST ELEV

SCALE : 1/4" = 1'-0"

INT KITCH WEST ELEV

REV DATE DESCRIPTION

3 03/13/26 BID PACK 2 - BIDS &PERMITS

4 04/03/26 BID PACK 2 - ADDENDUM 1

GENERAL FINISH NOTES

A. COMPLY WITH MANUFACTURER'S RECOMMENDATIONS FOR

PREPARING AND INSTALLING FINISHES.

B. PROTECT ADJACENT WORK BY SUITABLY COVERING DURING WORK.

C. REMOVE ADHESIVE OR PAINT SPOTS FROM FINISHED FLOORS,

WALLS, GLASS OR OTHER SURFACES. FINISHES TO MEET OR

EXCEED CODE REQUIREMENTS.

D. INSTALL MATERIALS USING MANUFACTURER'S APPROVED

ADHESIVES AND METHODS, U.O.N.

E. FILL MINOR DRYWALL IRREGULARITIES WITH SPACKLING COMPOUND

AND SAND TO A SMOOTH LEVEL SURFACE. EXERCISE CARE TO AVOID

RAISING THE NAP OF PAPER

F. DO NOT PERFORM PAINTING AND OTHER FINISHING WORK UNDER

CONDITIONS UNSUITABLE FOR EXECUTION OF PAINTING WORK. AIR

SHALL BE FREE FROM DUST AND DIRT TO PREVENT LODGING OF

FOREIGN MATTER IN FRESH PAINT. FLOORS MUST BE BROOM CLEAN

BEFORE PAINTING IS STARTED.

G. PAINT DESIGNATIONS INDICATE LOCATION ONLY. OWNER TO MAKE

FINAL DECISIONS ON COLOR AND SHEEN.

H. EDGES OF PAINT ADJOINING OTHER COLORS OR MATERIALS TO BE

SHARP AND CLEAN WITHOUT OVERLAP.

I. EXAMINE SURFACES TO RECEIVE PAINT CAREFULLY FOR DEFECTS.

DO NOT PROCEED WITH WORK UNTIL DEFECTS ARE CORRECTED.

J. WHENEVER NECESSARY TO OBTAIN REQUIRED RESULTS, REFINISH

AN ENTIRE WALL RATHER THAN SPOT FINISHING WHERE A PORTION

OF THE FINISH HAS BEEN DAMAGED OR IS UNSATISFACTORY.

K. PREPARE FLOOR SURFACES INCLUDING, BUT NOT LIMITED TO, THE

FOLLOWING:

A. PREPARE/PROPERLY REPAIR AND PATCH SUBFLOORS TO A

SMOOTH AND LEVEL FINISH.

B. FLASH PATCH AS REQUIRED, READY TO RECEIVE NEW FINISH.

L. PROVIDE THE REQUIRED TRANSITIONS BASED ON TYPES IDENTIFIED

ON DRAWINGS AT EACH FINISH TRANSITION LOCATION

M. CENTER FLOOR MATERIAL TRANSITIONS ON DOOR ABOVE.

N. FINISHED FLOORS EXTEND INTO TOE SPACES, CLOSETS, DOOR

REVEALS AND SIMILAR OPENINGS.

O. REFER TO REFLECTED CEILING PLANS FOR CEILING FINISHES.

P. ALL EXPOSED CONDUIT AND MISC STEEL TO BE PAINTED TO MATCH

ADJACENT SURFACE.

Q. CONTRACTOR REQUIRED TO PROVIDE DETAILED SHOP SUBMITTALS

WITH REQUIRED STRIPING DIMENSIONS TO MEET REGIONAL, STATE,

AND NATIONAL COMPETITION GUIDELINES FOR HIGHSCHOOL

BASKETBALL, VOLLEYBALL, AND PICKLEBALL.

MULTI PURPOSE

A-108

KITCHEN PREP

WEST EGRESS LOBBY

A-122

EAST EGRESS LOBBY

A-125

CORR

A-80B

CORR

A-80D

STORAGE

93S

CORRIDOR

80A

EP-1

EP-1

P-3

EXISTING

RB-1

P-1P-1

P-2

P-2

P-4

P-4

P-4

P-4

P-4

P-4

FLOOR FINISH

WALL BASE FINISH

FLOOR FINISH ONLY

GENERAL WALL FINISH

WALL FINISH ABOVE WAINSCOT

WAINSCOT FINISH

WINDOW TREATMENT

SIGNAGE TAG

FINISH SYMBOL LEGEND

XX#

XX#

XX#

X#

X# X#

X#

ACCENT WALL FINISH - TO EXTENTS

X#

X#

09 65 13 RESILIENT BASE AND ACCESSORIES

BASIS OF DESIGN

09 91 23 INTERIOR PAINTING

RB-1

MANUFACTURER: ROPPE

TYPE:

SIZE: 4" COVE

COLOR: TBD

P-1

MANUFACTURER: SHERWIN WILLIAMS

COLOR: MATCH EXISTING

FINISH: EGGSHELL

LOCATION: FIELD PAINT COLOR

P-2

MANUFACTURER: SHERWIN WILLIAMS

COLOR: MATCH EXISTING

FINISH: EGGSHELL

LOCATION: ACCENT PAINT COLOR

09 67 23 RESINOUS FLOORING

P-3

MANUFACTURER: SHERWIN WILLIAMS

COLOR: MATCH EXISTING

FINISH: SEMIGLOSS

LOCATION: FIELD PAINT COLOR - KITCHEN PREP

EP-1

MANUFACTURER: SHERWIN WILLIAMS

STYLE: RESUFLOR DECO FLAKE BC

COLOR: TBD BY CLIENT FROM MANUF STANDARD COLORS

06 41 16 ARCHITECTURAL CABINETS

PLAM-1

MANUFACTURER: FORMICA

STYLE: DAINTREE 8235-05

FINISH: TIMBERGRAIN

LOCATION: KITCHEN PREP

12 36 61.16 SOLID SURFACING COUNTERTOPS

SS-1

MANUFACTURER: WILSONART

STYLE: DUSK ICE

LOCATION: KITCHEN PREP

09 84 00 FIXED SOUND ABSORPTIVE PANELS

SAP-1: HIGH NRC DIRECT ATTACH WALL PANELS

MANUFACTURER: TECTUM DIRECT ATTACH

SIZE: 1", 4' X 6' AND 4' X 8' PANELS

COLOR: NATURAL (TNA)

*PANELS TO BE PAINTED SAME COLOR OF ADJACENT WALL

EDGES: BEVELED

LOCATION: MULTI-PURPOSE

P-4

MANUFACTURER: SHERWIN WILLIAMS

COLOR: TBD

FINISH: SEMIGLOSS

LOCATION: HM DOOR & FRAMES

09 91 23 INTERIOR PAINTING CONT.

P-5

MANUFACTURER: SHERWIN WILLIAMS

COLOR: MATCH EXISTING

FINISH: FLAT

LOCATION: CEILING/DECKING

P-6

MANUFACTURER: SHERWIN WILLIAMS

COLOR: MATCH COLOR OF P-1

FINISH: FLAT

LOCATION: TECTUM PANELS

P-7

MANUFACTURER: SHERWIN WILLIAMS

COLOR: MATCH COLOR OF P-2

FINISH: FLAT

LOCATION: TECTUM PANELS

Colliers Engineering & Design, Architecture, Landscape Architecture, Surveying, CT P.C.

Colliers

Engineering & Design

Colliers

Engineering & Design

GRAND RAPIDS

560 5th St. NW

Suite 305

Grand Rapids, MI 49504

Phone: 616.827.4270

A R

C H

D x

PROJECT MANAGER:

DESIGNER: REVIEWER:

DISCIPLINE LEAD:

DRAWING NUMBER:

DATE ISSUED: PROJECT NUMBER:

SHEET NAME:

Copyright © 2024. Colliers Engineering & Design All Rights Reserved. This drawing and all the information contained herein is authorized for use only by the party for whom the services were contracted or to whom it is certified. This drawing may not be copied, reused, disclosed, distributed or relied upon for any other purpose without the express written consent of

Colliers Engineering & Design.

www.colliersengineering.com

NOTE: DO NOT SCALE DRAWING FOR CONSTRUCTION.

MI ARCHITECTURE

FIRM LICENSE # NLP000605

TRUE NORTHPLAN NORTH

/3

/2

:1 :5

P

M

ATTWOOD CAFETERIA

AND KITCHEN

RENOVATIONS SO-1851

915 ATTWOOD DR

LANSING, MI 48911

C NORRIS

A141

FIRST FLOOR FINISH

PLAN

LANSING SCHOOL

DISTRICT

04/03/26 26000747A

SCALE : 1/8" = 1'-0"

FIRST FLOOR FINISH PLAN

ROOM FINISH SCHEDULE

ROOM

FLOOR BASE

WALL FINISH CEILING

FINISH REMARKSNUMBER NAME NORTH EAST SOUTH WEST

FIRST FLOOR

91 KITCHEN PREP EXISTING RB-1 P-3 P-3 P-3 P-3 EXISTING EXISTING FLOOR WILL NEED TO BE

PATCHED FOR NEW CASEWORK LAYOUT

A-108 MULTI

PURPOSE

EP-1 EP-1 P-2 P-1 P-2 P-1 P-5

REV DATE DESCRIPTION

3 03/13/26 BID PACK 2 - BIDS &PERMITS

4 04/03/26 BID PACK 2 - ADDENDUM 1

064116 - PLASTIC-LAMINATE-CLAD ARCHITECTURAL CABINETS

1. PRODUCTS

1.1 PLASTIC-LAMINATE-CLAD ARCHITECTURAL CABINETS

A. QUALITY STANDARD: UNLESS OTHERWISE INDICATED, COMPLY WITH THE ARCHITECTURAL

WOODWORK STANDARDS FOR GRADES OF CABINETS INDICATED FOR CONSTRUCTION,

FINISHES, INSTALLATION, AND OTHER REQUIREMENTS.

a. PROVIDE CERTIFICATES FROM AWI CERTIFICATION PROGRAM INDICATING THAT

WOODWORK AND INSTALLATION COMPLIES WITH REQUIREMENTS OF GRADES

SPECIFIED.

b. THE CONTRACT DOCUMENTS CONTAIN REQUIREMENTS THAT ARE MORE STRINGENT

THAN THE REFERENCED QUALITY STANDARD. COMPLY WITH REQUIREMENTS OF

CONTRACT DOCUMENTS IN ADDITION TO THOSE OF THE REFERENCED QUALITY

STANDARD.

B. ARCHITECTURAL WOODWORK STANDARDS GRADE: CUSTOM.

C. TYPE OF CONSTRUCTION: FRAMELESS.

D. DOOR AND DRAWER-FRONT STYLE: FLUSH OVERLAY.

E. HIGH-PRESSURE DECORATIVE LAMINATE: NEMA LD 3, GRADES AS INDICATED OR IF NOT

INDICATED, AS REQUIRED BY QUALITY STANDARD.

a. BASIS-OF-DESIGN PRODUCT: AS INDICATED.

F. LAMINATE CLADDING FOR EXPOSED SURFACES:

a. HORIZONTAL SURFACES: GRADE HGS.

b. POST-FORMED SURFACES: GRADE HGP.

c. VERTICAL SURFACES: GRADE HGS.

d. EDGES: GRADE HGS.

e. PATTERN DIRECTION: VERTICALLY GOT DRAWER FRONTS, DOORS, AND FIXED PANELS.

G. MATERIALS FOR SEMI-EXPOSED SURFACES:

a. SURFACES OTHER THAN DRAWER BODIES: HIGH PRESSIRE DECORATIVE LAMINATE, NEMA LD 3, GRADE VGS.

• EDGES OF PLASTIC-LAMINATE SHELVES: PVC TAPE, 0.018-INCH MINIMUM THICKNESS,

MATCHING LAMINATE IN COLOR, PATTERN, AND FINISH.

• FOR SEMI-EXPOSED BACKS OF PANELS WITH EXPOSED PLASTIC-LAMINATE

SURFACES, PROVIDE SURFACE OF HIGH-PRESSURE DECORATIVE LAMINATE, NEMA

LD 3, GRADE VGS.

b. DRAWER SIDES AND BACKS: SOLID-HARDWOOD LUMBER.

c. DRAWER BOTTOMS: HARDWOOD PLYWOOD.

H. DUST PANELS: 1/4-INCH PLYWOOD OR TEMPERED HARDBOARD ABOVE COMPARTMENTS AND

DRAWERS UNLESS LOCATED DIRECTLY UNDER TOPS.

I. CONCEALED BACKS OF PANELS WITH EXPOSED PLASTIC-LAMINATE SURFACES: HIGH-

PRESSURE DECORATIVE LAMINATE, NEMA LD 3, GRADE BKL.

J. DRAWER CONSTRUCTION: FABRICATE WITH EXPOSED FRONTS FASTENED TO SUBFRONT

WITH MOUNTING SCREWS FROM INTERIOR TO BODY.

a. JOIN SUBFRONTS, BACKS, AND SIDES WITH GLUED RABBETED JOINTS SUPPLEMENTED

BY MECHANICAL FASTENERS.

1.2. WOOD MATERIALS

A. PROVIDE MATERIALS THAT COMPLY WITH REQUIREMENTS OF REFERENCED QUALITY

STANDARD FOR EACH TYPE OF ARCHITECTURAL CABINET AND QUALITY GRADE SPECIFIED.

a. WOOD PRODUCTS:

• WOOD MOISTURE CONTENT: 5 TO 10 PERCENT.

b. COMPOSITE WOOD PRODUCTS:

• PRODUCTS SHALL BE MADE WITHOUT UREA FORMALDEHYDE.

• SOFT PLYWOOD: DOC PS 1, MEDIUM-DENSITY OVERLAY.

• THERMALLY FUSED LAMINATE (TFL) PANELS: PARTICLE BOARD OR MDF FINISHED

WITH THERMALLY FUSED, MELAMINE-IMPREGNATED DECORATIVE PAPER AND

COMPLYING WITH REQUIREMENTS OF NEMA LD 3, GRADE VGL, FOR TEST METHODS

3.3, 3.4, 3.6, 3.8, AND 3.10.

1.3. CABINET HARDWARE AND ACCESSORIES

A. WIRE PULLS: BACK MOUNTED, SOLID METAL, 4 INCHES LONG, 5/16 INCH IN DIAMETER.

B. HINGED DOORS: DOORS 36 INCHES AND MORE IN HEIGHT SHALL HAVE THREE HINGES AND

DOORS LESS THAN 36 INCHES IN HEIGHT SHALL HAVE TWO HINGES. EACH DOOR SHALL CLOSE

AGAINST TWO RUBBER BUMPERS.

a. HINGES: FABRICATE HINGES WITH MINIMUM 2 MM THICK CHROMIUM PLATED STEEL LEAVES, AND WITH MINIMUM 3.5 MM DIAMETER STAINLESS STEEL PIN. HINGES SHALL BE FIVE

KNUCKLE DESIGN WITH 63 MM HIGH LEAVES AND HOSPITAL TYPE TIPS.

b. FASTENERS: PROVIDE FULL THREAD WOOD SCREWS TO FASTEN HINGE LEAVES TO

DOOR AND CABINET FRAME. FINISH SCREWS TO MATCH FINISH OF HINGES.

C. CATCHES: MAGNETIC CATCHES, ANSI/BHMA A156.9, B03141.

D. ADJUSTABLE SHELF STANDARDS AND SUPPORTS: ANSI/BHMA A156.9, B04071; WITH SHELF

RESTS, B04081.

E. SHELF RESTS: ANSI/BHMA A156.9, B04013; METAL.

F. DRAWER SLIDES: ANSI/BHMA A156.9.

a. HEAVY-DUTY (GRADE 1HD-100 AND GRADE 1HD-200): SIDE MOUNT.

• TYPE: FULL EXTENSION.

• MATERIAL: ALUMINUM SLIDES.

• MOTION FEATURE: SELF-CLOSING MECHANISM.

G. DOOR AND DRAWER SILENCERS: ANSI/BHMA A156.16, L03011.

1.4 MISCELLANEOUS MATERIALS

A. FURRING, BLOCKING, SHIMS, AND HANGING STRIPS: SOFTWOOD OR HARDWOOD LUMBER,

KILN-DRIED TO LESS THAN 15 PERCENT MOISTURE CONTENT.

B. ANCHORS: SELECT MATERIAL, TYPE, SIZE, AND FINISH REQUIRED FOR EACH SUBSTRATE

FOR SECURE ANCHORAGE. PROVIDE METAL EXPANSION SLEEVES OR EXPANSION BOLTS

FOR POST-INSTALLED ANCHORS. USE NONFERROUS-METAL OR HOT-DIP GALVANIZED

ANCHORS AND INSERTS AT INSIDE FACE OF EXTERIOR WALLS AND AT FLOORS.

C. ADHESIVES: DO NOT USE ADHESIVES THAT CONTAIN UREA FORMALDEHYDE.

D. ADHESIVE FOR BONDING PLASTIC LAMINATE: UNPIGMENTED CONTACT CEMENT .

a. ADHESIVE FOR BONDING EDGES: HOT-MELT ADHESIVE OR ADHESIVE SPECIFIED ABOVE

FOR FACES.

099123 - INTERIOR PAINTING:

A. BASIS OF DESIGN MANUFACTURER: SHERWIN WILLIAMS. ALSO ACCEPTABLE: BENJAMIN

MOORE AND PPG PAINTS.

B. PREPARATION OF SURFACES TO RECEIVE PAINT: CLEAN, DRY, DULL, AND SOUND.

C. PAINT SYSTEMS:

a. CMU:

• PRIMER: EXTREME BOND PRIMER, B51 SERIES

1. 3.1 MILS WET, .9 MILS DRY.

• ADHESION TEST: USE PRINCIPLES OF ASTM D3359 AFTER MINIMUM 7 DAY CURE TIME

OF PRIMER TO ENSURE 90% OF COATING CONTINUES TO ADHERE, CONTACT

COATINGS MANUFACTURER FOR ASSISTANCE AS NEEDED.

• INTERMEDIATE COAT: MATCH TOPCOAT.

• TOPCOAT: PRO INDUSTRIAL PRE-CAT EPOXY, K45-2150 SERIES.

1. 4.0 MILS WET, 1.6 MILS DRY PER COAT.

b. HOLLOW METAL FRAMES AND DOORS:

• PRIMER: PRO INDUSTRIAL PRO CRYL UNIVERSAL PRIMER, B66-310 SERIES.

1. 5.0 TO 10 MILS WET, 2.0 TO 4.0 MILS DRY.

• INTERMEDIATE COAT: MATCH TOPCOAT.

• TOPCOAT: PRO INDUSTRIAL ACRYLIC SEMI-GLOSS COAT, B66-650 SERIES.

1. 2.5 TO 4.0 MILS DRY PER COAT.

c. GYPSUM BOARD AND PLASTER:

• PRIMER: PROMAR 200 ZERO VOC INTERIOR LATEX PRIMER, B28W2600

1. 4.0 MILS WET, 1.0 MILS DRY.

• INTERMEDIATE COAT: MATCH TOPCOAT.

• TOPCOAT: PROMAR 200 ZERO VOC INTERIOR LATEX EG-SHEL, B20-2600 SERIES.

1. 4.0 MILS WET, 1.6 MILS DRY.

d. STEEL DECKING

• PRIMER: PRO INDUSTRIAL PRO-CRYL UNIVERSAL PRIMER, B66-310 SERIES

• INTERMEDIATE COAT: MATCH TOPCOAT

• TOPCOAT: PRO INDUSTRIAL WATERBORNE ACRYLIC DRY FALL, FLAT, B42-80 SERIES

e. ACOUSTIC/TECTUM DECK

• PRO INDUSTRIAL WATERBORNE ACRYLIC DRY FALL, FLAT, B42-80 SERIES. UP TO 6

COATS, SPRAY APPLIED.

1. 3.5 TO 5.0 MILS WET, 1.5 TO 2.0 MILS DRY PER COAT.

D. COLORS: REFER TO BASIS OF DESIGN.

101100 - VISUAL DISPLAY UNITS:

A. MANUFACTURERS: ADP LEMCO., BANGOUR CORK COMPANY, INC., CIG-JAN PRODUCTS, LTD., CLARIDGE PRODUCTS AND EQUIPMENT, INC. MARSH INDUSTRIES, INC., MARSH INDUSTRIES, INC.

B. TACKBOARD PANEL: POLYESTER-FABRIC-FACED TACKBOARD PANEL W/ ALUMINUM FRAMES

AND TRIM.

C. DISPLAY RAIL: MANUFACTURER'S STANDARD, EXTRUDED ALUMINUM DISPLAY RAIL WITH

PLASTIC-IMPREGNATED-CORK INSERT AND END STOPS.

SYMBOL NOTES:

1. "AC" DENOTES ABOVE COUNTER. COORDINATE HEIGHT WITH ARCHITECT.

2. "H" DENOTES HORIZONTAL MOUNTING OF DEVICE.

3. "B" DENOTES MOUNTED IN BASE.

4. "F" DENOTES MOUNTED IN FACE OF CABINETS.

T THERMOSTAT. E.C TO ROUGH-IN SINGLE GANG BOX AND

1/2"C. TO ACCESSIBLE CEILING SPACE.

TRANSFORMER

SURFACE OR FLUSH MTD. BRANCH CIRCUIT PANELBOARD

THREE PHASE ELECTRIC MOTOR

SINGLE PHASE ELECTRIC MOTOR

MAGNETIC MOTOR STARTER-MS

DIMMER SWITCH

46"

KEY OPERATED SWITCH-SPEC. GRADE

FOUR WAY SWITCH-SPEC. GRADE

T

F

P

F

J

ELECTRICAL SYMBOL LEGEND

S

S

S

WR

D

K

S

SYMBOL DESCRIPTION

MTG. HT. TO CL

SPECIAL OUTLET-CHARACTERISTICS AS NOTED ON PLANS

FLOOR BOX 1 RECEPT, 1 DATA - THOMAS & BETTS-# 664-SC

1-1/4"C TO FLOORBOX FOR DATA

FLOOR BOX 2 RECEPT, 2 DATA THOMAS & BETTS-# 665-SC

1-1/4"C TO FLOORBOX FOR DATA

OS

IRDS IR SWITCH DIMMABLE

OCCUPANCY SENSOR

PUSH BUTTONPB

TV

IRS IR SWITCH

CS CONTROL STATION

C

SPECIAL SINGLE RECEPTACLE

VARIABLE FREQUENCY DRIVEVFD

PC PHOTO CELL

46"

46"

46"

46"

46"

46"

18"

18"

18"

18"

18"

AS NOTED

18"

46"

46"

46"

AT EQUIP.

AS NOTED

AS NOTED

46"

46"

46"

46"

72" TO TOP

18"

SINGLE POLE OR 3-WAY SWITCH-

SPECIFICATION GRADE

SPLIT WIRED RECEPTACLE

C - DENOTES CONTROLLED VIA RELAY OR OCC SENSOR

WATER RESISTANT GROUND FAULT CIRCUIT INTERRUPTER

WR-DENOTES WEATHERPROOF WHILE IN USE COVER

DUPLEX OUTLET-SPEC. GRADE

CIRCLE AROUND SYMBOL= CEILING MOUNTED

DATA OUTLET-4" SQ. BOX W/ 1 GANG RAISED COVER.

1-1/4"C. UP WALL TO CLG. SPACE

CIRCLE AROUND SYMBOL= CEILING MOUNTED

TV OUTLET-4" SQ. BOX W/ 1 GANG RAISED COVER.

1-1/4"C. UP WALL TO CLG. SPACE

CIRCLE AROUND SYMBOL= CEILING MOUNTED

JUNCTION BOX - HUBBELL NSAV62M WITH RECEPTACLE KIT

HUBBELL NSOKP. PROVIDE CONNECTOR PLATE FOR A/V

JUNCTION BOX -4" SQ. BOX W/ 2 GANG RAISED COVER.

1"C. UP WALL TO CLG. SPACE UNLESS OTHERWISE NOTED

FUSED DISCONNECT SWITCH-

FDS-HEAVY DUTY

NON-FUSED DISCONNECT SWITCH-

NFDS-HEAVY DUTY

SW. AND PLUGFUSE HOLDER- BUSSMANN

"SSU" & FUSESTAT FUSE

COMBINATION MAG. STARTER/ FUSED DISC. SWITCH - CS/FDS

COMBINATION MAG. STARTER/NON-FUSED DISC.

SWITCH - CS/NFDS

(2) DUPLEX OUTLET-SPEC. GRADE

CIRCLE AROUND SYMBOL= CEILING MOUNTED

S

PARTIALLY SHADED LUMINAIRE OR WITH "E" SUFFIX ARE

EMERGENCY

BATTERY EMERGENCY LUMINAIRE

REMOTE EMERGENCY HEAD

RECESSED LUMINAIRE 2'x4' OR 2'x2'

RECESSED WALLWASH LUMINAIRE

RECESSED DOWNLIGHT LUMINAIRE

LED ACCENT/UNDER CABINET LUMINAIRE

TRACK LIGHTING LUMINAIRE

SURFACE LUMINAIRE

WALL MOUNTED LUMINAIRE

PENDANT LUMINAIRE

SITE LIGHTING LUMINAIRE

NIGHT LIGHT

STRIP LUMINAIRE

SURFACE LUMINAIRE 2'x4' OR 2'x2'

EXIT SIGN - WALL MOUNTED OR CEILING MOUNTED

ARROWS INDICATE PATH OF EGRESS

NL

EE

H HUMIDISTAT. E.C TO ROUGH-IN SINGLE GANG BOX AND

1/2"C. TO ACCESSIBLE CEILING SPACE. 46"

WN ---

PS SWITCH WITH PILOT LIGHT 46"

18"TELEPHONE OUTLET-4" SQ. BOX W/ 1 GANG RAISED

COVER. 1-1/4"C. UP WALL TO CLG. SPACE

18"TELEPHONE/DATA OUTLET-4" SQ. BOX W/ 1 GANG

RAISED COVER. 1-1/4"C. UP WALL TO CLG. SPACE

M ---ELECTRIC UTILITY METER

P ---POWER POLE - SEE DRAWING FOR POWER -

POWER/DATA SPECIFICATIONS

DS DAYLIGHT SENSOR ---

MS MANUAL MOTOR STARTER SWITCH 46"

ELECTRICAL IDENTIFICATION

N.T.S.

FRONT

REAR SIDE

OF PLATE

FRONT

REAR SIDE OF

PLATE

BPA-15LP2-5

LABEL CKT. NO. OF EACH DEVICE ON REAR

SIDE OF COVER PLATE. USE PERMANENT

MARKER PEN, BRADY MARKING SYSTEM OR

OTHER METHOD APPROVED BY THE ENGINEER

JUNCTION BOXES (EXPOSED

OR CONCEALED ABOVE

ACCESSIBLE CEILING)

LABEL COVERS WITH CKT.'S CONTAINED

WITHIN. USE PERMANENT MARKER PEN

OR OTHER APPROVED METHOD.

FOR J.B.'S CONTAINING OTHER

THAN POWER OR LIGHTING CKT.'S

LABEL COVERS INDICATING

SYSTEM TYPE AND ZONES.

CKT.S

LP4-13,15,17

DUPLEX RECEPTACLE

PLATE

STANDARD TOGGLE

SWITCH PLATE

LABEL EXAMPLES:

"FIRE ALARM-ZONES 2&3"

"P.A. ZONES 4,5,&6" "DATA

CIRCUITS A&B" "EXIT

SIGNS-EMI&2" "EMERG.

CKTS. BPEM-3,4"

E100 A-1

PP POWER PACK ---

EV ---EV CHARGER

F= FUTURE

WIRELESS ROUTER

CIRCLE AROUND SYMBOL= CEILING MOUNTED

M

EX. UTILITY

TRANSFORMER

120/240V 3Ø

EX PANEL EMDP-01

120/240V 1Ø, 3W, 800A,65KAIC

2P800A

2P100A

2P125A

UTILITY

EX

UTILITY

METER

EX. EBCP06

EX. EBCP07

EXISTING 120/240V- 1Ø-3W PARTIAL ONE LINE

NOT TO SCALE

2P225A

2P225A

ATTWOOD CAFETERIA

AND KITCHEN

RENOVATIONS

915 ATTWOOD DR

LANSING, MI 48911

C NORRIS

E POST

B HUYLER

E100

ELECTRICAL SYMBOLS

AND SPECIFICATIONS

LANSING SCHOOL

DISTRICT

03/13/26 26000747A

REV DATE DESCRIPTION

Colliers Engineering & Design, Architecture, Landscape Architecture, Surveying, CT P.C.

Colliers

Engineering & Design

Colliers

Engineering & Design

GRAND RAPIDS

560 5th St. NW

Suite 305 Grand Rapids, MI 49504

Phone: 616.827.4270

AR

C

H D

4x

PROJECT MANAGER:

DESIGNER: REVIEWER:

DISCIPLINE LEAD:

DRAWING NUMBER:

DATE ISSUED: PROJECT NUMBER:

KEY PLAN

SHEET NAME:

NOTE: DO NOT SCALE DRAWING FOR CONSTRUCTION.

MI ARCHITECTURE

FIRM LICENSE # NLP000605

TRUE NORTHPLAN NORTH

www.colliersengineering.com Copyright © 2024. Colliers Engineering & Design All Rights

Reserved. This drawing and all the information contained herein is authorized for use only by the party for whom the services were contracted or to whom it is certified. This drawing may not be copied, reused, disclosed, distributed or relied upon for any other purpose without the express written consent of Colliers Engineering & Design.

ATTWOOD CAFETERIA

AND KITCHEN

RENOVATIONS

915 ATTWOOD DR

LANSING, MI 48911

LANSING SCHOOL

DISTRICT

03/13/26 26000747A

REV DATE DESCRIPTION

0 04/03/2026 BID PACK 2 - ADDENDUM 1

100 Cesar E Chavez Ave SW Grand Rapids, Michigan 49503

(616) 742-2810 www.classicengineering.com Project # 2026095

Classic Engineering, LLC

A-108

KITCHEN PREP

STORAGE

93S

CORRIDOR

80A

EAST EGRESS LOBBY

A-125

WEST EGRESS LOBBY

A-122

CORR

A-80D

CORR

A-80B

1 1 1 1

EBCP-06/1 EBCP-06/3 EBCP-06/5 EBCP-06/7

A

A

A

A

A

A

A

A

A

AE

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

AE

A

A

A

A

A

A

A

AE

A

A

EM1

EM1

MULTI PURPOSE

A-108

KITCHEN PREP

STORAGE

93S

CORRIDOR

80A

EAST EGRESS LOBBY

A-125

WEST EGRESS LOBBY

A-122

CORR

A-80D

CORR

A-80B

1 1 1 1EBCP-06/1 EBCP-06/3 EBCP-06/5 EBCP-06/7

2 2

ATTWOOD CAFETERIA

AND KITCHEN

RENOVATIONS

915 ATTWOOD DR

LANSING, MI 48911

C NORRIS

E POST

B HUYLER

EL101

FIRST FLOOR PLAN -

LIGHTING

LANSING SCHOOL

DISTRICT

03/13/26 26000747A

REV DATE DESCRIPTION

Colliers Engineering & Design, Architecture, Landscape Architecture, Surveying, CT P.C.

Colliers

Engineering & Design

Colliers

Engineering & Design

GRAND RAPIDS

560 5th St. NW

Suite 305 Grand Rapids, MI 49504

Phone: 616.827.4270

AR

C

H D

4x

PROJECT MANAGER:

DESIGNER: REVIEWER:

DISCIPLINE LEAD:

DRAWING NUMBER:

DATE ISSUED: PROJECT NUMBER:

KEY PLAN

SHEET NAME:

NOTE: DO NOT SCALE DRAWING FOR CONSTRUCTION.

MI ARCHITECTURE

FIRM LICENSE # NLP000605

TRUE NORTHPLAN NORTH

www.colliersengineering.com Copyright © 2024. Colliers Engineering & Design All Rights

Reserved. This drawing and all the information contained herein is authorized for use only by the party for whom the services were contracted or to whom it is certified. This drawing may not be copied, reused, disclosed, distributed or relied upon for any other purpose without the express written consent of Colliers Engineering & Design.

ATTWOOD CAFETERIA

AND KITCHEN

RENOVATIONS

915 ATTWOOD DR

LANSING, MI 48911

LANSING SCHOOL

DISTRICT

03/13/26 26000747A

REV DATE DESCRIPTION

0 04/03/2026 BID PACK 2 - ADDENDUM 1

100 Cesar E Chavez Ave SW Grand Rapids, Michigan 49503

(616) 742-2810 www.classicengineering.com Project # 2026095

Classic Engineering, LLC

SCALE: 1/8" = 1'-0"

GENERAL LIGHTING NOTES:

1. CONNECT EMERGENCY LIGHTING TO CIRCUIT FEEDING GENERAL LIGHTING IN THAT AREA.

2. EXIT SIGNS TO BE CONNECTED TO UNSWITCHED LIGHTING CIRCUIT OR EMERGENCY LIGHTING

CIRCUIT FEEDING THAT AREA.

3. LIGHTING CONTROL SHALL COMPLY WITH 2021 MICHIGAN ENERGY CODE WHERE APPLICABLE.

LIGHTING KEY NOTES:

INSTALL NEW LIGHT FIXTURES USING EXISTING CIRCUITS MADE AVAILABLE DURING DEMOLITION.1

SCALE: 1/8" = 1'-0"

REMOVE EXISTING LIGHTING. DISPOSE OF LIGHT FIXTURES AND LAMPS IN PROPER AND

LEGAL MANNER. IF FLUORESCENT ARE TO BE REMOVED, DISPOSE AT AN APPROVED

RECYCLING SITE. MAINTAIN CIRCUIT FOR NEW LIGHT FIXTURE INSTALLATION. MAINTAIN

CONTROLS THROUGHOUT DEMOLITION.

NO WORK IN AREA. EXISTING EXIT LIGHTS TO REMAIN.

DEMOLITION POWER KEYNOTES:

KITCHEN PREP

STORAGE

93S

CORRIDOR

80A

EAST EGRESS LOBBY

A-125

WEST EGRESS LOBBY

A-122

CORR

A-80D

CORR

A-80B

0.7

0.8

0.9

1.0

1.1

1.2

1.3

1.3

1.3

1.3

1.2

1.1

1.0

0.9

0.8

0.8

0.7

0.6

0.6

0.6

0.6

0.8

1.0

1.2

1.4

1.3

1.2

1.0

0.7

0.8

0.9

1.0

1.2

1.3

1.3

1.4

1.4

1.4

1.3

1.2

1.1

1.0

0.9

0.8

0.7

0.7

0.6

0.6

0.6

0.7

0.9

1.4

2.0

2.2

2.0

2.4

2.4

1.7

0.7

0.8

1.0

1.1

1.2

1.3

1.4

1.4

1.4

1.4

1.3

1.2

1.1

1.0

0.9

0.8

0.7

0.7

0.6

0.6

0.7

0.9

1.3

2.3

4.2

3.9

2.9

3.9

5.4

3.4

0.7

0.8

1.0

1.1

1.2

1.3

1.4

1.4

1.4

1.4

1.3

1.2

1.1

1.0

0.9

0.8

0.8

0.7

0.7

0.7

0.8

1.0

1.6

3.5

5.7

5.2

2.9

4.1

4.5

0.7

0.8

0.9

1.0

1.2

1.2

1.3

1.4

1.4

1.3

1.3

1.2

1.1

1.0

0.9

0.8

0.8

0.7

0.7

0.7

0.8

1.1

1.8

3.4

4.2

3.6

2.2

2.6

3.9

3.5

0.7

0.8

0.9

1.0

1.1

1.2

1.3

1.3

1.3

1.3

1.3

1.2

1.1

1.0

0.9

0.8

0.8

0.7

0.7

0.8

0.9

1.1

1.6

2.2

2.6

2.1

1.6

1.6

2.1

2.4

0.7

0.8

0.9

1.0

1.1

1.2

1.2

1.3

1.3

1.3

1.2

1.1

1.1

1.0

0.9

0.8

0.8

0.8

0.8

0.8

0.9

1.0

1.2

1.5

1.5

1.3

1.2

1.2

1.3

1.3

0.7

0.8

0.9

1.0

1.0

1.1

1.2

1.2

1.2

1.2

1.2

1.1

1.1

1.0

0.9

0.9

0.8

0.8

0.8

0.8

0.9

0.9

1.0

1.1

1.1

1.0

1.0

1.0

1.0

0.9

0.7

0.8

0.9

0.9

1.0

1.1

1.2

1.2

1.2

1.2

1.2

1.1

1.1

1.0

0.9

0.9

0.8

0.8

0.8

0.9

0.9

0.9

1.0

1.0

1.0

0.9

0.9

0.9

0.9

0.8

0.7

0.8

0.9

1.0

1.0

1.1

1.2

1.2

1.2

1.2

1.2

1.1

1.1

1.0

1.0

0.9

0.9

0.9

0.9

0.9

0.9

1.0

1.0

1.0

1.0

1.0

0.9

0.9

0.8

0.8

0.7

0.8

0.9

1.0

1.1

1.1

1.2

1.2

1.2

1.2

1.2

1.1

1.1

1.0

1.0

0.9

0.9

0.9

0.9

1.0

1.0

1.0

1.0

1.1

1.0

1.0

1.0

0.9

0.9

0.8

0.7

0.8

0.9

1.0

1.1

1.2

1.2

1.3

1.3

1.3

1.2

1.2

1.1

1.1

1.0

1.0

1.0

1.0

1.0

1.0

1.1

1.1

1.1

1.1

1.1

1.1

1.0

1.0

0.9

0.9

0.7

0.8

0.9

1.0

1.1

1.2

1.3

1.3

1.4

1.3

1.3

1.2

1.2

1.1

1.1

1.0

1.0

1.0

1.0

1.1

1.1

1.2

1.2

1.2

1.2

1.2

1.1

1.1

1.0

0.9

0.7

0.8

0.9

1.1

1.2

1.3

1.4

1.4

1.4

1.4

1.4

1.3

1.2

1.2

1.1

1.1

1.1

1.1

1.1

1.1

1.2

1.3

1.3

1.3

1.3

1.3

1.2

1.1

1.0

0.9

0.7

0.9

1.0

1.1

1.2

1.3

1.4

1.5

1.5

1.5

1.4

1.3

1.3

1.2

1.1

1.1

1.1

1.1

1.1

1.2

1.3

1.3

1.4

1.4

1.4

1.3

1.3

1.2

1.1

1.0

0.7

0.9

1.0

1.1

1.2

1.3

1.4

1.5

1.5

1.5

1.4

1.4

1.3

1.2

1.2

1.1

1.1

1.1

1.2

1.2

1.3

1.4

1.4

1.4

1.4

1.4

1.3

1.2

1.1

1.0

0.7

0.8

1.0

1.1

1.2

1.3

1.4

1.5

1.5

1.5

1.4

1.3

1.3

1.2

1.1

1.1

1.1

1.1

1.2

1.2

1.3

1.4

1.4

1.4

1.4

1.4

1.3

1.2

1.1

1.0

0.7

0.8

0.9

1.0

1.1

1.2

1.3

1.4

1.4

1.4

1.3

1.3

1.2

1.2

1.1

1.1

1.1

1.1

1.1

1.2

1.2

1.3

1.3

1.4

1.4

1.3

1.3

1.2

1.1

1.0

0.5

0.5

5.8

1.9 2.2

3.4

4.7

2.0

2.8

3.6

3.4

2.7

1.6

2.8

4.7

5.6

3.9

0.7

1.3

2.4

4.9

4.5

0.6

1.0

1.6

2.7

3.8

3.6

0.6

0.7

1.1

1.4

1.8

2.1

0.5

0.6

0.7

0.9

1.0

1.1

0.4

5.9

AE @ 22'

AE @ 22'

AE @ 22'

EM1 @ 7.5'

EM1 @ 7.5'

Statistics

Description Symbol Avg Max Min Max/Min Avg/Min

CORR A-80D 2.3 fc 5.9 fc 0.4 fc 14.8:1 5.8:1 MULTI PURPOSE A108 1.2 fc 5.8 fc 0.5 fc 11.6:1 2.4:1

Schedule

Symbol Label Image QTY Catalog Number Description Lamp Number Lamps

Lumens per Lamp LLF Wattage Polar Plot

AE 3 LBL4 4000LM 80CRI 35K LBL4 4000 lumen, 80CRI, 3500K 1 4187.931 1 32.41

EM1 4 ELM4L SP640L 640 lumen, 6.6 watt, Spot Pattern 1 345 1 2.5

ATTWOOD CAFETERIA

AND KITCHEN

RENOVATIONS

915 ATTWOOD DR

LANSING, MI 48911

C NORRIS

E POST

B HUYLER

EL102

FIRST FLOOR PLAN -

EMERGENCY LIGHTING

LANSING SCHOOL

DISTRICT

03/13/26 26000747A

REV DATE DESCRIPTION

Colliers Engineering & Design, Architecture, Landscape Architecture, Surveying, CT P.C.

Colliers

Engineering & Design

Colliers

Engineering & Design

GRAND RAPIDS

560 5th St. NW

Suite 305 Grand Rapids, MI 49504

Phone: 616.827.4270

AR

C

H D

4x

PROJECT MANAGER:

DESIGNER: REVIEWER:

DISCIPLINE LEAD:

DRAWING NUMBER:

DATE ISSUED: PROJECT NUMBER:

KEY PLAN

SHEET NAME:

NOTE: DO NOT SCALE DRAWING FOR CONSTRUCTION.

MI ARCHITECTURE

FIRM LICENSE # NLP000605

TRUE NORTHPLAN NORTH

www.colliersengineering.com Copyright © 2024. Colliers Engineering & Design All Rights

Reserved. This drawing and all the information contained herein is authorized for use only by the party for whom the services were contracted or to whom it is certified. This drawing may not be copied, reused, disclosed, distributed or relied upon for any other purpose without the express written consent of Colliers Engineering & Design.

ATTWOOD CAFETERIA

AND KITCHEN

RENOVATIONS

915 ATTWOOD DR

LANSING, MI 48911

LANSING SCHOOL

DISTRICT

03/13/26 26000747A

REV DATE DESCRIPTION

0 04/03/2026 BID PACK 2 - ADDENDUM 1

100 Cesar E Chavez Ave SW Grand Rapids, Michigan 49503

(616) 742-2810 www.classicengineering.com Project # 2026095

Classic Engineering, LLC

SCALE: 1/8" = 1'-0"

GENERAL LIGHTING NOTES:

1. CONNECT EMERGENCY LIGHTING TO CIRCUIT FEEDING GENERAL LIGHTING IN THAT AREA.

2. EXIT SIGNS TO BE CONNECTED TO UNSWITCHED LIGHTING CIRCUIT OR EMERGENCY LIGHTING

CIRCUIT FEEDING THAT AREA.

3. LIGHTING CONTROL SHALL COMPLY WITH 2021 MICHIGAN ENERGY CODE WHERE APPLICABLE.

KITCHEN PREP

STORAGE

93S

EAST EGRESS LOBBY

A-125

WEST EGRESS LOBBY

A-122

VEST

A-123

VEST

A-126

CORR

A-80B

CORR

A-80D

CORRIDOR

80A

GYMNASIUM

A-124

A101 4

A101 67

EX. PANEL EBCP06

EX. PANEL EBCP07

ETR. GFCI RECEPTACLE

EBCP07-4

NEW GFCI RECEPTACLE

EBCP06-2

MULTI PURPOSE

A-108

KITCHEN PREP

STORAGE

93S

CORRIDOR

80A

WEST EGRESS LOBBY

A-122

EAST EGRESS LOBBY

A-125

VEST

A-126

VEST

A-123

GYMNASIUM

A-124

CORR

A-80B

CORR

A-80D

SPEC ED

CLASSROOM

110K

CONF

92 EXTERIOR COURTYARD

STRIP MULTI-PURPOSE

ROOM WALLS AND

ATTACHMENTS OF

EXISTING PAINT FINISH.

PREP SURFACE TO

RECEIVE NEW PAINT.

NO WORK

EX. PANEL EBCP06

EX. PANEL EBCP07

ETR. GFCI RECEPTACLE

EBCP07-4

ATTWOOD CAFETERIA

AND KITCHEN

RENOVATIONS

915 ATTWOOD DR

LANSING, MI 48911

C NORRIS

E POST

B HUYLER

EP101

FIRST FLOOR PLAN -

POWER

LANSING SCHOOL

DISTRICT

03/13/26 26000747A

REV DATE DESCRIPTION

Colliers Engineering & Design, Architecture, Landscape Architecture, Surveying, CT P.C.

Colliers

Engineering & Design

Colliers

Engineering & Design

GRAND RAPIDS

560 5th St. NW

Suite 305 Grand Rapids, MI 49504

Phone: 616.827.4270

AR

C

H D

4x

PROJECT MANAGER:

DESIGNER: REVIEWER:

DISCIPLINE LEAD:

DRAWING NUMBER:

DATE ISSUED: PROJECT NUMBER:

KEY PLAN

SHEET NAME:

NOTE: DO NOT SCALE DRAWING FOR CONSTRUCTION.

MI ARCHITECTURE

FIRM LICENSE # NLP000605

TRUE NORTHPLAN NORTH

www.colliersengineering.com Copyright © 2024. Colliers Engineering & Design All Rights

Reserved. This drawing and all the information contained herein is authorized for use only by the party for whom the services were contracted or to whom it is certified. This drawing may not be copied, reused, disclosed, distributed or relied upon for any other purpose without the express written consent of Colliers Engineering & Design.

ATTWOOD CAFETERIA

AND KITCHEN

RENOVATIONS

915 ATTWOOD DR

LANSING, MI 48911

LANSING SCHOOL

DISTRICT

03/13/26 26000747A

REV DATE DESCRIPTION

0 04/03/2026 BID PACK 2 - ADDENDUM 1

100 Cesar E Chavez Ave SW Grand Rapids, Michigan 49503

(616) 742-2810 www.classicengineering.com Project # 2026095

Classic Engineering, LLC

SCALE: 1/8" = 1'-0"

RECONNECT POWER TO WATER HEATER, REUSE EXISTING CIRCUIT.

REMOVE EXISTING RECEPTACLES IN AREA. REPLACE WITH GREY TAMPER PROOF RECEPTACLES

WITH STAINLESS STEEL COVER PLATES.

REUSE EXISTING CIRCUIT FOR NEW COOLER.

POWER KEYNOTES:

GENERAL POWER NOTES:

1. ALL 15A & 20A 120V NON-LOCKING RECEPTACLES WITH PUBLIC SPACES WHERE CHILDREN CAN

BE FOUND SHALL BE LISTED TAMPER RESISTANT PER NEC 406.12. THIS INCLUDES SCHOOLS,

HOTELS, CLINICS, OUTPATIENT FACILITIES, PLACES OF WAITING AND ALL COMMON USE AREAS

(CORRIDORS, GYM, MUSIC ETC.).

2. VERIFY ALL KITCHEN EQUIPMENT REQUIREMENTS, CONNECTION TYPES, AND LOCATIONS WITH

KITCHEN EQUIPMENT SUPPLIER AND NAMEPLATES PRIOR TO ROUGH-IN.

3. EXISTING FIRE ALARM DEVICES TO REMAIN.

DISCONNECT EXISTING WATER HEATER CIRCUIT UNDER SINK. MAINTAIN CIRCUIT FOR

REINSTALLATION. MAINTAIN WATER HEATER FOR REINSTALLATION. FIELD VERIFY

EXISTING CIRCUIT.NEW LOCATION TO BE DETERMINED BY OWNER.

NO WORK IN AREA.

DEMOLITION POWER KEYNOTES:

SCALE: 1/8" = 1'-0"

LANSING SCHOOL DISTRICT

2026 SUMMER PROJECTS

KITCHEN REMODEL PROJECTS

BID PACKAGE #2

CM CLARIFICATION #1

CM CLARIFICIATION #1

1. Attwood Elementary:

A. The Tectum Panels will be an accent color and they should be painted before they are installed.

B. The exposed ceiling will be painted with SW Flat Ceiling Paint.

C. The Paint Specification is on Sheet A141.

2. Ebersole Center:

A. Painting notes are on Sheet A101.

B. Wood trim will be painted with SW Semi-Gloss, Color to match existing trim.

C. Walls and ceilings will be painted with SW Eggshell, Color to match existing.

D. The painter will not be required to provide plywood floor protection for Tectum Ceiling touch up paint.

3. Dwight Rich:

A. Paint Specification is on Sheet A101.

4. Gardner Elementary:

A. Paint Specification is on Sheet A141.

B. Any areas where masonry infill is noted will need to be primed and painted, P-1.

C. Masonry infill is located at Passage D122, Passage D124, New Cooler 130B, Dishwash Area A134 and any other location that note new masonry walls.

D. Several HM door frames require paint as noted on Sheet A141. All new doors will be factory finished.

KITCHEN REMODEL PROJECTS

BID PACKAGE #2

CM CLARIFICATION #2

CM CLARIFICIATION #2

1. General note for Attwood Elementary:

Resinous Flooring is removed from the Painting Division ‘D’ and moved to Bid Division ‘C’ Flooring.

The flooring bidders must include an allowance of $5,000.00 for nonstandard prep work.

There will be substantial prep work involved with the Attwood floor project and the flooring contractor will be expected to track the floor prep hours and collect signed T&M slips from the CM Superintendent. When the project is finished the flooring contractor must submit the slips to be billed against the allowance and a change order will be issued to cover the transaction.

2. If painters want to bid on the resinous floor work they should include voluntary alternates on the bid form for the resinous flooring at Attwood and Gardner.

KITCHEN REMODEL PROJECTS

BID PACKAGE #2

CM CLARIFICATION #3

CM CLARIFICIATION #3

1. The current Bid Division E – Mechanical has been divided into two separate divisions. Bid Division E will be “Plumbing” and Bid Division “G” will be HVAC.

2. Bid Division E – Plumbing will include:

Section 024119 Selective Demo 078400 Firestopping 220000 Plumbing

Gardner Phase 1 includes Kitchen Area only to be completed Summer of 2026.

Gardner Phase 2 will proceed in Summer 2027.

All Plumbing demolition detailed on the drawings is included in this contract.

The day these projects start the plumbing contractor must be on site to disconnect kitchen equipment so the food service contractor can remove it.

This division includes labor, material, and equipment to furnish and install all plumbing including all domestic water systems, pipes, pumps, heads, sanitary soil waste and vent systems, storm drain systems, Grease trap and vent system, plumbing fixtures and equipment, traps and supports, insulation for plumbing systems and fixture installation, pipe and valve identification for a complete and operating system as shown and/or specified.

This division includes supply and installation of all gas piping and regulators, supply and installation of stainless-steel sinks in prefabricated casework, water heaters, condensate drains and fireproof sealants where plumbing work penetrates fire rated walls and ceilings.

The plumbing plans detail several new sanitary lines that must be connected to existing UG sanitary piping.

In areas that require cutting, removal and replacement of concrete floors, the General Trades Contractor will remove and replace the concrete. The Plumbing Contractor must perform all required excavation, backfill, compaction and removal of excess dirt.

The drawings detail several new water pipes to connect to new equipment and fixtures and this piping is included in the Plumbing division.

This division includes the following prep work for the Food Service Equipment Contractor.

All required rough-ins and piping with stop valves, elbows, nipples, couplers, traps, waste vents, gas regulators for water, steam, gas, etc. and will also make final connections to the equipment. The plumber will also install all equipment accessories furnished by the FSEC. The plumber will provide the required water heater and piping unless noted otherwise and plumbing, mechanical and electrical subs shall disconnect and reconnect relocated equipment if applicable.

This division includes all required permits and fees as required by state code. Housekeeping and cleanup on a daily basis is included in this division.

KITCHEN REMODEL PROJECTS

BID PACKAGE #2

CM CLARIFICATION #3

This division includes as built drawings, operation and maintenance manuals, owner training and specified attic stock material.

Gardner Phase 1 includes all work in Kitchen Area including Rooms 130A, 134, 136 and 137.

Gardner Phase 2 includes the balance of the Plumbing work including Rooms 131, 132, 129, 133, 121 and

125.

3. Bid Division G – HVAC will include:

Section 024119 Selective Demo 078400 Firestopping

230000 HVAC

Gardner Elementary is the only school that includes HVAC work.

Gardner Phase 1 includes Kitchen Area only to be completed Summer of 2026.

Gardner Phase 2 will proceed in Summer 2027.

Any roof patching must be scheduled with the roofing company that holds the warranties for these projects.

If roof curbs are required, they must be provided with the roof top equipment. Placement of roof top equipment must be approved by the CM. If additional steel is required, the CM will arrange for supply and erection of the steel.

This division includes labor, material and equipment to make the specified revisions to the HVAC system as detailed in the contract documents. The majority of the HVAC work involves revisions to the existing ductwork, grilles, diffusers and dampers, but if the documents specify new equipment such as pumps, stacks, flues, unit heaters, air handling units, unit vents, exhaust fans or furnaces, this contractor must provide and install all of the specified equipment.

Any required connections or adjustments to the ATC / BMS system are included in this contract. All engineering, installation, calibration, software programming and start-up of the ATC / BMS system are included in this contract.

Any specified testing and balance for the HVAC systems is included in this division.

This division includes all required permits and fees as required by state code. Housekeeping and cleanup on a daily basis is included in this division.

This division includes as built drawings, operation and maintenance manuals, owner training and specified attic stock material.

Gardner Phase 1 includes all work in Kitchen Area including Rooms 130A, 134, 136 and 137.

Gardner Phase 2 includes the balance of the HVAC work including Rooms 131, 132, 129, 133, 121 and

125.

LSD Attwood Cafeteria and Kitchen Renovations
Addendum No. 1
Narrative of Changes
General Notes/ Clarifications

File details come from the government source that posted it. Updated .