26-0306 LSD Gardner - BID PACK 2 - Addendum 2.pdf
PDF 252 KB Posted
- Attached to
- School Kitchen Renovations
- Solicitation number
- RFP LSD 260000001562 3
- Issued by
- Ingham County, Michigan
About this file
This is Addendum No. 2 to Bid Pack 2 for the Gardner Elementary Food Service Equipment Replacement & Renovations project issued by the Lansing School District on April 6, 2026. The addendum revises contract documents for food service equipment replacement and facility renovations at Gardner Elementary School located at 333 Dahlia Drive, Lansing, Michigan 48911. The project is managed by architect Colliers Engineering & Design (Project Number 26000752A) and issued to Beckering Construction. This addendum specifically addresses revisions to Drawing A601 (Door Schedule and Specifications), which were reissued to include hardware set numbers and comprehensive door hardware specifications and sets for the project. The addendum details 13 doors scheduled for renovation across the first floor, with specifications for door types, dimensions, materials, finishes, and associated hardware ratings.
The addendum establishes five hardware sets (numbered 01 through 05) with detailed specifications for components including hinges, locks, closers, kick plates, and gasketing from manufacturers such as Ives, Schlage, LCN, and Zero International. Interior doors are specified as solid-core five-ply flush wood veneer-faced doors with red oak faces and fire-rated construction where required. Hardware finishes are predominantly specified in satin chromium (BHMA 626/652 US26D), with permanent keying to be provided by the owner using an existing factory-registered system. Painting specifications include Sherwin Williams products for CMU, hollow metal frames, and gypsum board surfaces, with detailed wet and dry mil requirements for primer, intermediate, and topcoat applications. All hardware and accessibility features must comply with 2017 ICC 117.1 and ADA requirements.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LSD Gardner Food Service – Bid Pack 2, Addendum No. 2 – Narrative of Changes Page 1 | 2
LSD Gardner Food Service Bid Pack 2, Addendum No. 2 Narrative of Changes
Project Name: Gardner Elementary Food Service – Equipment Replacement & Renovations SO-1852
Date: April 6, 2026
Project Location:
333 Dahlia Dr, Lansing, MI 48911
Architect’s Project #: 26000752A
Owner/Client: Lansing School District Attention: David Beckering
Issued to: Beckering Construction Email: djb@beckering.com City/State: Grand Rapids, MI Zip: 49548
Delivered via:
This Addendum revises the Contract Documents and shall have the same force and effect;
make the following changes to the Specifications and Drawings for this project. The following is a written summary of the changes made by this Addendum. Strict attention should be given to the Drawings and Specifications for area take-off, quantities and items deleted or revised herein. This addendum forms a part of the Contract Documents.
Issued by CED by: Courtney Norris Date Signed: 04/06/2026 Prepared by: Courtney Norris Date Signed: 04/06/2026 Distribution:
Below is a list of the changes made to our documents in response to the comments, RFIs, or clarifications provided prior to Bid. Please feel free to reach out with any further questions or clarifications in a timely manner.
Sincerely, Courtney Norris
☐ Messenger
☐ Express
☐ Hand-carried
☐ Pick-up
☐ UPS
Address Sent to:
☐ Newforma
☐ FTP
LSD Gardner Food Service – Bid Pack 2, Addendum No. 2 – Narrative of Changes Page 2 | 2
Drawings
• A601 – DOOR SCHEUDLE AND SPECIFICATIONS (Reissued) o Added hardware set numbers to the door schedule o Added door hardware specifications and sets
ATTACHMENTS
Reissued Drawings:
A601
END OF ADDENDUM NO. 2
NG
SCHEDULE
SEE
S E
E S
C H
E D
U L E
6" 9"
F
SCHEDULE
SEE
S E
E S
C H
E D
U L E
Colliers Engineering & Design, Architecture, Landscape Architecture, Surveying, CT P.C.
Colliers
Engineering & Design
Colliers
Engineering & Design
GRAND RAPIDS
560 5th St. NW
Suite 305
Grand Rapids, MI 49504
Phone: 616.827.4270
A R
C H
D x
PROJECT MANAGER:
DESIGNER: REVIEWER:
DISCIPLINE LEAD:
DRAWING NUMBER:
DATE ISSUED: PROJECT NUMBER:
SHEET NAME:
Copyright © 2024. Colliers Engineering & Design All Rights Reserved. This drawing and all the information contained herein is authorized for use only by the party for whom the services were contracted or to whom it is certified. This drawing may not be copied, reused, disclosed, distributed or relied upon for any other purpose without the express written consent of
Colliers Engineering & Design.
www.colliersengineering.com
NOTE: DO NOT SCALE DRAWING FOR CONSTRUCTION.
MI ARCHITECTURE
FIRM LICENSE # NLP000605
E F
D
CB
A
KEY PLAN
BID PACK 2
/6
/2
:1
:1
P
M
GARDNER ELEMENTARY
FOOD SERVICE - EQUIPMENT
REPLACEMENT &
RENOVATION SO-1852
333 DAHLIA DRIVE
LANSING, MI 48911
C NORRIS
E POST
B HUYLER
A601
DOOR SCHEDULE AND
SPECIFICATIONS
LANSING SCHOOL
DISTRICT
4/6/26 26000752A
DOOR SCHEDULE
DOOR #
DOOR FRAME GENERAL
DOOR #
WIDTH
LEAF 1
WIDTH
LEAF 2 HEIGHT T
H
K
T Y
P E
M A
T -F
IN
T Y
P E
M A
T -F
IN
H D
W R
R A
T
IN
G
REMARKS
FIRST FLOOR
129A
3' - 0" 7' - 0" 0' - 1 3/4" NG WD - ST EXIST EXIST -
NEW PAINT
NEW DOOR + HDWR, EXIST
FRAME (PH. 2)
129A
3' - 0" 3' - 0" 7' - 0" 0' - 1 3/4" F WD - ST EXIST EXIST -
NEW PAINT
MIN
(2) NEW DOORS + HDWR,
EXIST FRAME (PH. 2)
132A
3' - 0" 7' - 0" 0' - 1 3/4" NG WD - ST EXIST EXIST -
NEW PAINT
NEW DOOR + HDWR, EXIST
FRAME (PH. 2)
132A
133A
3' - 0" 7' - 0" 0' - 1 3/4" NG WD - ST EXIST EXIST -
NEW PAINT
NEW DOOR + HDWR, EXIST
FRAME (PH. 2)
133A
133B
3' - 0" 7' - 0" 0' - 1 3/4" NG WD - ST EXIST EXIST -
NEW PAINT
NEW DOOR + HDWR, EXIST
FRAME (PH. 2)
133B
133C
3' - 1" 7' - 0" 0' - 1 3/4" NG WD - ST EXIST EXIST -
NEW PAINT
NEW DOOR + HDWR, EXIST
FRAME (PH. 2)
133C
133D
3' - 0" 7' - 0" 0' - 1 3/4" NG WD - ST EXIST EXIST -
NEW PAINT
NEW DOOR + HDWR, EXIST
FRAME (PH. 2)
133D
136A
3' - 8" 7' - 0" 0' - 1 3/4" F WD - ST EXIST EXIST -
NEW PAINT
MIN
NEW DOOR + HDWR, EXIST
FRAME (PH. 1) VERIFY SIZE OF
OPENING AND ANY RATING
REQUIREMENTS IN FIELD
136A
D-118
3' - 0" 3' - 0" 7' - 0" 0' - 1 3/4" F WD - ST EXIST EXIST -
NEW PAINT
MIN
(2) NEW DOORS + HDWR,
EXIST FRAME (PH. 2)
D-118
D-126
3' - 0" 3' - 0" 7' - 0" 0' - 1 3/4" F WD - ST EXIST EXIST -
NEW PAINT
MIN
(2) NEW DOORS + HDWR,
EXIST FRAME (PH. 2)
D-126
D-135A
3' - 0" 7' - 0" 0' - 1 3/4" F WD - ST EXIST EXIST -
NEW PAINT
NEW DOOR + HDWR, EXIST
FRAME (PH. 1)
D-135A
DOOR - TYPES
REV DATE DESCRIPTION
3 03/13/26 BID PACK 2 - BIDS & PERMITS
4 03/04/26 BID PACK 2 - ADDENDUM 1
5 04/06/26 BID PACK 2 - ADDENDUM 2
081416 - FLUSH WOOD DOORS
A. ACCEPTABLE MANUFACTURERS: EGGERS INDUSTRIES, OSHKOSH DOOR COMPANY, VT
INDUSTRIES, AND FORTE OPENING SOLUTIONS (MASONITE ARCHITECTURAL).
B. INTERIOR DOORS: SOLID-CORE FIVE-PLY FLUSH WOOD VENEER-FACED DOORS FOR
TRANSPARENT FINISH.
a. PERFORMANCE GRADE: ANSI/WDMA I.S. 1A EXTRA HEAVY DUTY.
b. FACES: PLAIN SLICED RED OAK, CENTER-BALANCE MATCH.
c. EXPOSED VERTICAL AND TOP EDGES: SAME SPECIES AS FACES, ARCHITECTURAL
WOODWORK STANDARDS EDGE TYPE A.
d. FIRE RATED DOORS: PROVIDE EDGE CONSTRUCTION WITH INTUMESCENT SEALS
CONCEALED BY OUTER STILE.
e. CORE FOR FIRE-RATED DOORS: AS REQUIRED TO ACHIEVE FIRE-PROTECTION RATING
INDICATED ON SCHEDULE.
C. FINISH: FACTORY FINISH, TRANSPARENT, SATIN, STAIN COLOR TO BE SELECTED BY
ARCHITECT FROM MANUFACTURER'S STANDARD
COLORS.
087100 - DOOR HARDWARE:
A. MANUFACTURERS/PRODUCTS
a. HINGES: IVES 5BB SERIES. ALSO ACCEPTABLE: HAGER BB1191/1279 SERIES OR MCKINNEY TB
SERIES.
b. CONTINUOUS HINGES: IVES. ALSO ACCEPTABLE: SELECT OR PEMKO.
c. FLUSH BOLTS: IVES. ALSO ACCEPTABLE: TRIMCO OR ROCKWOOD.
d. COORDINATORS: IVES. ALSO ACCEPTABLE: TRIMCO OR ROCKWOOD.
e. MORTISE LOCKS: SCHLAGE L9000 SERIES. ALSO ACCEPTABLE: SARGENT 8200 SERIES.
• WARRANTY: 10 YEARS.
f. EXIST DEVICES: VON DUPRIN 98/35A SERIES. ALSO ACCEPTABLE: SARGENT 19-43-GL-80
SERIES.
g. CYLINDERS: BEST. NO SUBSTITUTION. PROVIDE INTERCHANGEABLE CYLINDERS/CORES TO
MATCH OWNER'S EXISTING KEY SYSTEM, COMPLIANT WITH ANSI/BHMA A156.5; LATEST
REVISION.
h. DOOR CLOSERS: LCN 4040XP SERIES. ALSO ACCEPTABLE: SARGENT 281 SERIES.
• WARRANTY: 30 YEARS.
i. PROTECTION PLATES: IVES. ALSO ACCEPTABLE: TRIMCO OR ROCKWOOD.
j. OVERHEAD STOPS AND OVERHEAD STOP/HOLDERS: GLYNN-JOHNSON. ALSO ACCEPTABLE:
SARGENT OR ABH.
k. DOOR STOPS AND HOLDERS: IVES. ALSO ACCEPTABLE: TRIMCO OR ROCKWOOD.
l. THRESHOLDS, SEALS, DOOR SWEEPS, AUTOMATIC DOOR BOTTOMS, AND GASKETING: ZERO
INTERNATIONAL. ALSO ACCEPTABLE: NATIONAL GUARD, REESE, OR PEMKO.
m. FINISHES: GENERALLY, SATIN CHROMIUM, BHMA 626/652 (US26D). PROVIDE FINISH FOR EACH
ITEM AS INDICATED IN THE SETS.
B. KEYING
a. SCHEDULED SYSTEM:
• EXISTING FACTORY REGISTERED SYSTEM:
1. PROVIDE CYLINDERS/CORES 0-BITTED FOR OWNER'S EXISTING FACTORY
REGISTERED KEYING SYSTEM. COMPLY WITH GUIDELINES IN ANSI/BHMA A156.28.
b. REQUIREMENTS:
• PERMANENT KEYING: PROVIDED BY OWNER.
C. HARDWARE SET #01 (DOORS 129A, 132A)
a. (3) EA HINGE - 5BB1HW/SW (SIZE AS REQ'D) - FINISH 652 - MFR IVE
- CONFIRM HINGE REQ. TO MATCH EXISTING FRAME PREPS
b. (1) EA CLASSROOM LOCK - L9070BDC 03A - FINISH 626 - MFR SCH
c. (1) EA PERMANENT CORE - CONTRACTOR SUPPLIED: TO BE COMBINATED BY OWNER - MFR
BES
d. (1) EA OH STOP & HOLDER - 90H - FINISH 630 - MFR GLY
e. (1) EA SURFACE CLOSER - 4040XP RW/PA TBSRT - FINISH 689 - MFR LCN
- PULL-SIDE
f. (1) EA KICK PLATE - 8400 10" X 2" LDW B-CS - FINISH 630 - MFR IVE
g. NOTES: FIELD VERIFY EXISTING CONDITIONS. VERIFY/COORDINATE PREPS ON EXISTING
FRAMES TO ENSURE THE COMPATIBILITY OF NEW HARDWARE PRIOR TO ORDER OF NEW
MATERIALS. PROVIDE FIELD MODIFICATIONS AND/OR NECESSARY FILLERS (PAINT TO MATCH
WHERE EXISTING IS PREVIOUSLY PAINTED), REINFORCEMENTS AND FASTENERS,
COMPATIBLE WITH EXISTING MATERIALS REQUIRED FOR MOUNTING NEW SPECIFIED
HARDWARE AND TO COVER EXISTING FRAME PREPARATIONS.
D. HARDWARE SET #02 (DOOR D-135A)
a. (3) EA HINGE - 5BB1HW/SW (SIZE AS REQ'D) NRP - FINISH 628 - MFR IVE
b. (1) EA CLASSROOM LOCK - L9070BDC 03A - FINISH 626 - MFR SCH
c. (1) EA PERMANENT CORE - CONTRACTOR SUPPLIED: TO BE COMBINATED BY OWNER - MFR
BES
d. (1) EA SURFACE CLOSER - 4040XP CUSH TBSRT - FINISH 689 - MFR LCN
e. (1) EA KICK PLATE - 8400 10" X 2" LDW B-CS - FINISH 630 - MFR IVE
f. NOTES: FIELD VERIFY EXISTING CONDITIONS. VERIFY/COORDINATE PREPS ON EXISTING
FRAMES TO ENSURE THE COMPATIBILITY OF NEW HARDWARE PRIOR TO ORDER OF NEW
MATERIALS. PROVIDE FIELD MODIFICATIONS AND/OR NECESSARY FILLERS (PAINT TO MATCH
WHERE EXISTING IS PREVIOUSLY PAINTED), REINFORCEMENTS AND FASTENERS,
COMPATIBLE WITH EXISTING MATERIALS REQUIRED FOR MOUNTING NEW SPECIFIED
HARDWARE AND TO COVER EXISTING FRAME PREPARATIONS.
E. HARDWARE SET #03 (DOORS 131, D-118, D-126)
a. (6) EA HINGE - 5BB1HW/SW (SIZE AS REQ'D) NRP - FINISH 652 - MFR IVE
- CONFIRM HINGE REQ. TO MATCH EXISTING FRAME PREPS
b. (1) EA CONST LATCHING BOLT - FB51P - FINISH 630 - MFR IVE
c. (1) EA DUST PROOF STRIKE - DP2 - FINISH 626 - MFR IVE
d. (1) EA CLASSROOM LOCK - L9070BDC 03A - FINISH 626 - MFR SCH
e. (1) EA PERMANENT CORE - CONTRACTOR SUPPLIED: TO BE COMBINATED BY OWNER - MFR
BES
f. (1) EA COORDINATOR - COR X FL - FINISH 628 - MFR IVE
g. (2) EA MOUNTING BRACKET - MB (AS REQ'D) - FINISH 689 - MFR IVE
h. (2) EA SURFACE CLOSER - 4040XP SCUSH TBSRT - FINISH 689 - MFR LCN
i. (1) EA GASKETING - 488S - FINISH BK - MFR ZER
j. (1) EA MEETING STILE - 8217S - FINISH BK - MFR ZER
k. NOTES: FIELD VERIFY EXISTING CONDITIONS. VERIFY/COORDINATE PREPS ON EXISTING
FRAMES TO ENSURE THE COMPATIBILITY OF NEW HARDWARE PRIOR TO ORDER OF NEW
MATERIALS. PROVIDE FIELD MODIFICATIONS AND/OR NECESSARY FILLERS (PAINT TO MATCH
WHERE EXISTING IS PREVIOUSLY PAINTED), REINFORCEMENTS AND FASTENERS,
COMPATIBLE WITH EXISTING MATERIALS REQUIRED FOR MOUNTING NEW SPECIFIED
HARDWARE AND TO COVER EXISTING FRAME PREPARATIONS PER NFPA 80.
SPECIFICATIONS
F. HARDWARE SET #04 (DOOR 136A)
a. (3) EA HINGE - 5BB1HW/SW (SIZE AS REQ'D) - FINISH 628 - MFR IVE
- CONFIRM HINGE REQ. TO MATCH EXISTING FRAME PREPS
b. (1) EA STOREROOM LOCK - LV9080BDC 03A - FINISH 626 - MFR SCH
c. (1) EA PERMANENT CORE - CONTRACTOR SUPPLIED: TO BE COMBINATED BY OWNER - MFR
BES
d. (1) EA SURFACE CLOSER - 4040XP RW/PA TBSRT - FINISH 689 - MFR LCN
- PULL-SIDE
e. (1) EA KICK PLATE - 8400 10" X 2" LDW B-CS - FINISH 630 - MFR IVE
f. (1) EA WALL STOP - WS406/407CVX - FINISH 630 - MFR IVE
g. (1) EA GASKETING - 488S - FINISH BK - MFR ZER
h. NOTES: FIELD VERIFY EXISTING CONDITIONS. VERIFY/COORDINATE PREPS ON EXISTING
FRAMES TO ENSURE THE COMPATIBILITY OF NEW HARDWARE PRIOR TO ORDER OF NEW
MATERIALS. PROVIDE FIELD MODIFICATIONS AND/OR NECESSARY FILLERS (PAINT TO MATCH
WHERE EXISTING IS PREVIOUSLY PAINTED), REINFORCEMENTS AND FASTENERS,
COMPATIBLE WITH EXISTING MATERIALS REQUIRED FOR MOUNTING NEW SPECIFIED
HARDWARE AND TO COVER EXISTING FRAME PREPARATIONS PER NFPA 80.
G. HARDWARE SET #05 (DOORS 133A, 133B, 133C, 133D)
a. (1) CONT. HINGE - 224XY - FINISH 628 - MFR IVE
b. (3) HINGE FILLER PLATE - SIZE AS REQ'D
c. (1) EA PANIC HARDWARE - CDSI-98-NL - FINISH 626 - MFR VON
d. (1) EA RIM CYLINDER - 1E72 (LESS CORE) - FINISH 626 - MFR BES
e. (1) EA MORTISE CYLINDER - 1E74 (LESS CORE) - FINISH 626 - MFR BES
f. (1) PERMANENT CORE - CONTRACTOR SUPPLIED: TO BE COMBINATED BY OWNER - MFR BES
g. (1) EA SURFACE CLOSER - 4040XP SCUSH TBSRT - FINISH 689 - MFR LCN
h. (1) KICK PLATE - 8400 10" X 2" LDW B-CS - FINISH 630 - MFR IVE
i. NOTES: FIELD VERIFY EXISTING CONDITIONS. VERIFY/COORDINATE PREPS ON EXISTING
FRAMES TO ENSURE THE COMPATIBILITY OF NEW HARDWARE PRIOR TO ORDER OF NEW
MATERIALS. PROVIDE FIELD MODIFICATIONS AND/OR NECESSARY FILLERS (PAINT TO MATCH
WHERE EXISTING IS PREVIOUSLY PAINTED), REINFORCEMENTS AND FASTENERS,
COMPATIBLE WITH EXISTING MATERIALS REQUIRED FOR MOUNTING NEW SPECIFIED
HARDWARE AND TO COVER EXISTING FRAME PREPARATIONS.
H. ALL HARDWARE TO MEET ACCESSIBILITY REQUIREMENTS SET BY 2017 ICC 117.1 AND ADA.
088000 - GLAZING:
A. MONOLITHIC GLASS:
a. HEAT STRENGTHENED FULLY TEMPERED FLOAT GLASS.
b. MINIMUM 6 MM THICK.
c. LOCATION: INTERIOR, NON-FIRE RATED LOCATIONS UNLESS OTHERWISE NOTED.
099123 - INTERIOR PAINTING:
A. BASIS OF DESIGN MANUFACTURER: SHERWIN WILLIAMS. ALSO ACCEPTABLE: BENJAMIN MOORE
AND PPG PAINTS.
B. PREPARATION OF SURFACES TO RECEIVE PAINT: CLEAN, DRY, DULL, AND SOUND.
C. PAINT SYSTEMS:
a. CMU (EXISTING PREVIOUSLY PAINTED):
• PRIMER: EXTREME BOND PRIMER, B51 SERIES
1. 3.1 MILS WET, .9 MILS DRY.
• ADHESION TEST: USE PRINCIPLES OF ASTM D3359 AFTER MINIMUM 7 DAY CURE TIME OF
PRIMER TO ENSURE 90% OF COATING CONTINUES TO ADHERE, CONTACT COATINGS
MANUFACTURER FOR ASSISTANCE AS NEEDED.
• INTERMEDIATE COAT: MATCH TOPCOAT.
• TOPCOAT: PRO INDUSTRIAL PRE-CAT EPOXY, K45-2150 SERIES.
1. 4.0 MILS WET, 1.6 MILS DRY PER COAT.
b. CMU (NEW/BARE):
• PRIMER: PRO INDUSTRIAL HEAVY DUTY BLOCK FILLER, B42 SERIES
• INTERMEDIATE COAT: MATCH TOP COAT
• TOPCOAT: PRO INDUSTRIAL PRE-CAT EPOXY, K45-2150 SERIES.
1. 4.0 MILS WET, 1.6 MILS DRY PER COAT.
c. HOLLOW METAL FRAMES AND DOORS:
• PRIMER: PRO INDUSTRIAL PRO CRYL UNIVERSAL PRIMER, B66-310 SERIES.
1. 5.0 TO 10 MILS WET, 2.0 TO 4.0 MILS DRY.
• INTERMEDIATE COAT: MATCH TOPCOAT.
• TOPCOAT: PRO INDUSTRIAL ACRYLIC SEMI-GLOSS COAT, B66-650 SERIES.
1. 2.5 TO 4.0 MILS DRY PER COAT.
d. GYPSUM BOARD AND PLASTER:
• PRIMER: PROMAR 200 ZERO VOC INTERIOR LATEX PRIMER, B28W2600
1. 4.0 MILS WET, 1.0 MILS DRY.
• INTERMEDIATE COAT: MATCH TOPCOAT.
• TOPCOAT: PROMAR 200 ZERO VOC INTERIOR LATEX EG-SHEL, B20-2600 SERIES.
1. 4.0 MILS WET, 1.6 MILS DRY.
D. COLORS: REFER TO BASIS OF DESIGN.
| LSD Gardner Food Service |
| Bid Pack 2, Addendum No. 2 |
| Narrative of Changes |
| Drawings |
File details come from the government source that posted it. Updated .