About this file
This is Addendum No. 1 to Bid Pack 2 for the Ebersole Center Food Service Equipment Replacement & Renovations project issued by Lansing School District on April 3, 2026. The project is located at 3400 2nd Street, Wayland, Michigan 49348, with Architect Project #26000750A. The addendum revises the contract documents and specifications for the kitchen renovation work, including modifications to architectural drawings, electrical specifications, and lighting plans. Key changes include reissued sheets A101 (First Floor and Ceiling Plans), E100 (Details, Symbol Legends & Specifications), EL101 (First Floor Plan - Lighting/Photometrics), and EP101 (First Floor Plan - Power). Notable revisions encompass added paint specifications, revised notes regarding column wraps and conduit routing, fixture schedule updates with Columbia manufacturer approval and Watt Stopper lighting control equivalents, modified kitchen and serving area lighting fixtures to Type B, and revised electrical device layouts at the serving line with provision for a rubber ramp to cover surface-mounted floor conduits. Three CM clarifications accompany the addendum addressing painting specifications, flooring division changes, and the separation of mechanical work into distinct plumbing and HVAC divisions for Gardner Elementary.
The addendum includes comprehensive specifications for interior painting utilizing Sherwin Williams products (Benjamin Moore and PPG acceptable alternatives) with detailed preparation and application requirements for various surfaces including gypsum board, plaster, concrete masonry units, hollow metal frames, doors, and wood trim. Paint systems specify primers, intermediate coats, and topcoats with specific mil thickness requirements and color matching to existing conditions. Electrical work specifications detail lighting fixture schedules, symbol legends, power distribution requirements, equipment connections, and safety provisions including tamper-resistant receptacles in areas accessible to children and GFCI circuit breaker protection. The document establishes responsibilities for trades coordination, requiring field verification of equipment locations and connections among food service, mechanical, plumbing, and electrical contractors. Three supporting CM clarifications address resinous flooring allowances, voluntary alternates for painters, and the division of mechanical work into separate plumbing and HVAC contracts with distinct scope definitions for Gardner Elementary's phased project approach (Phase 1 summer 2026, Phase 2 summer 2027).
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LSD Ebersole Center – Bid Pack 2, Addendum No. 1 – Narrative of Changes Page 1 | 2
LSD Ebersole Center Food Service Bid Pack 2, Addendum No. 1 Narrative of Changes
Project Name: Ebersole Center Food Service – Equipment Replacement & Renovations SO-1853
Date: April 3, 2026
Project Location:
3400 2nd St Wayland, MI 49348
Architect’s Project #: 26000750A
Owner/Client: Lansing School District Attention: David Beckering
Issued to: Beckering Construction Email: djb@beckering.com City/State: Grand Rapids, MI Zip: 49548
Delivered via:
This Addendum revises the Contract Documents and shall have the same force and effect;
make the following changes to the Specifications and Drawings for this project. The following is a written summary of the changes made by this Addendum. Strict attention should be given to the Drawings and Specifications for area take-off, quantities and items deleted or revised herein. This addendum forms a part of the Contract Documents.
Issued by CED by: Courtney Norris Date Signed: 04/03/2026 Prepared by: Courtney Norris Date Signed: 04/03/2026 Distribution: Refer to Newforma transmittal.
Below is a list of the changes made to our documents in response to the comments, RFIs, or clarifications provided prior to Bid. Please feel free to reach out with any further questions or clarifications in a timely manner.
Sincerely, Courtney Norris
☐ Messenger
☐ Express
☐ Hand-carried
☐ Pick-up
☐ UPS
Address Sent to:
☐ Newforma
☐ FTP
LSD Ebersole Center – Bid Pack 2, Addendum No. 1 – Narrative of Changes Page 2 | 2
Drawings
• A101 – FIRST FLOOR AND CEILING PLANS (Reissued) o Added paint specifications.
o Revised note regarding column wrap and conduit running inside of column wrap and across the floor.
o Revised note regarding painting of trim
• E100 – DETAILS, SYMBOL LEGENDS & SPECIFICATIONS
o Added new type b in fixture schedule o Added Columbia manufacturer to the schedule as approved o Allow watt stopper as approved equal for lighting controls
• EL101 – FIRST FLOOR PLAN – LIGHTING / PHOTOMETRICS (Reissued) o Changed fixtures in kitchen and serving 108 to type B
• EP101 – FIRST FLOOR PLAN – POWER (Reissued) o Changed keyed note 3 to utilize the column for conduit drops to serving line and provide a rubber ramp to cover surface mounted conduits along the floor.
o Revised device layout and notations at the serving line.
ATTACHMENTS
Reissued Sheets:
A101, E100, EL101, EP101
CM Clarifications 1, 2, 3
END OF ADDENDUM NO. 1
1009A
WALK-IN
COOLER
1009B
WALK-IN
FREEZER
MULTI-PORPOSE
ROOM
KITCHEN
SERVING
DISHWASHING
STORAGE
WC
COORDINATE ALL NEW
EQUIPMENT WITH FOOD
SERVICE AND MEP
DRAWINGS
V
IF
EXIST BULKHEAD ABOVE
EXIST BULKHEAD ABOVE
COORDINATE ALL NEW
EQUIPMENT WITH FOOD
SERVICE AND MEP
DRAWINGS
EXIST
EQUIPMENT TO
REMAIN (LIGHT
GRAY)
A1
A1
A2 A2
A2
A2
A3
A4
A5
A4
A3
A101
A101
Sim
A101
Sim
A101
Sim
REMOVE EXISTING TRACK
AND WOOD TRIM. RUN
CONDUIT DOWN COLUMN
AND WRAP COLUMN WITH
NEW 1x POPULAR TRIM
AND PAINT.
CONDUIT TO RUN ALONG FLOOR.
COORDINATE LOCATION OF BOXES
WITH FOOD SERVICE SHOP
DRAWINGS. PROVIDE RUBBER
RAMP OVER CONDUIT. BASIS OF
DESIGN: RUBBER FORM PIPE &
HOSE RAMP OR SIMILAR
COORDINATE
NEW EQUIPMENT
WITH EXISTING
VENTING TO
ROOF
NEW SURFACE
MOUNTED LIGHT
FIXTURES. REFER TO
ELECTRICAL DWGS
A101
C1
C2C2
C1
C3
C4
C4
C4
NEW SURFACE
MOUNTED LIGHT
FIXTURES. REFER TO
ELECTRICAL DWGS
CEILING LEGEND
NOTE: SEE OTHER DISCIPLINE DRAWINGS (E.G. MECHANICAL, PLUMBING
AND ELECTRICAL DRAWINGS) FOR ASSOCIATED SYSTEMS AND
INFORMATION ABOUT SYMBOLS NOT INDICATED IN THIS LEGEND.
4' x 8' TECTUM CEILING
GYPSUM BOARD CEILING/SOFFIT
OPEN TO DECK
REMOVE PARTITION
AND WOOD TRIM,
ENTIRE EXTENT OF
BULKHEAD EA SIDE
8' - 7 3/4"
B.O. TRIM VIF
(B.O. TRIM
7'-11 1/4" AT
SERVING, VIF)
REPLACE TRIM W/ NEW
NOMINAL 1x10 CONTINUOUS
POPULAR WOOD TRIM,
PAINTED SEMI-GLOSS, COLOR
TO MATCH EXISTING.
PROPOSED CONDUIT
LOCATION, REFER TO
ELEC. DWGS
NEW PAINTED TRIM AT
JAMB, BEYOND
A
REMOVE PARTITION
TRACK FROM WALL
AND EXISTING WOOD
JAMB TRIM, EA SIDE
PROVIDE NEW NOMINAL 1x10
CONTINUOUS POPULAR
WOOD , PAINTED SEMI-GLOSS,
COLOR TO MATCH EXISTING.
TRIM AT JAMB TO BE FLUSH
WITH TRIM AT HEAD
SCALE : 1/8" = 1'-0"
FIRST FLOOR PLAN
SCALE : 1/8" = 1'-0"
FIRST FLOOR REFLECTED CEILING PLAN
Colliers Engineering & Design, Architecture, Landscape Architecture, Surveying, CT P.C.
Colliers
Engineering & Design
Colliers
Engineering & Design
GRAND RAPIDS
560 5th St. NW
Suite 305
Grand Rapids, MI 49504
Phone: 616.827.4270
A R
C H
D x
PROJECT MANAGER:
DESIGNER: REVIEWER:
DISCIPLINE LEAD:
DRAWING NUMBER:
DATE ISSUED: PROJECT NUMBER:
SHEET NAME:
Copyright © 2024. Colliers Engineering & Design All Rights Reserved. This drawing and all the information contained herein is authorized for use only by the party for whom the services were contracted or to whom it is certified. This drawing may not be copied, reused, disclosed, distributed or relied upon for any other purpose without the express written consent of
Colliers Engineering & Design.
www.colliersengineering.com
NOTE: DO NOT SCALE DRAWING FOR CONSTRUCTION.
MI ARCHITECTURE
FIRM LICENSE # NLP000605
BID PACK 2
/3
/2
:3 :5
P
M
EBERSOLE CENTER FOOD
SERVICE - EQUIPMENT
REPLACEMENT &
RENOVATIONS SO-1853
3400 2ND STREET
WAYLAND, MI 49348
C NORRIS
E POST
B HUYLER
A101
FIRST FLOOR AND
CEILING PLANS
LANSING SCHOOL
DISTRICT
03/13/26 26000750A
N
SCALE : 1" = 1'-0"
PARTITION HEAD DTL
CEILING PLAN KEYNOTES #
C1 EXISTING CEILING TO REMAIN. PAINT TOUCH UP AS REQUIRED FOR
NEW LIGHT INSTALLATION.
C2 EXISTING TECTUM CEILING TO REMAIN. PAINT TOUCH UP AS
REQUIRED FOR NEW LIGHT INSTALLATION.
C3 EXISTING PLASTERED CEILING TO REMAIN. PATCH AND REPAIR
WATER DAMAGE AREAS AND PAINT ENTIRE CEILING.
C4 EXISTING PLASTERED CEILING TO REMAIN. PATCH AS REQUIRED
AND PAINT TOUCH UP AS REQUIRED FOR NEW LIGHT
INSTALLATION.
FLOOR PLAN KEYNOTES #
A1 EXISTING VCT FLOORING TO REMAIN. NO WORK ANTICIPATED.
A2 BULKHEAD AT FOLDING PARTITIONS TO BE PAINTED BOTH SIDES IN
ITS ENTIRETY. ALL OTHER WALLS TO REMAIN AS IS.
A3 EXISTING MOSAIC FLOOR TILING TO REMAIN. PATCH AS REQUIRED
FOR NEW POWER, DRAINS AND WATER LINES.
A4 PROVIDE PAINT TOUCH UP WHERE EQUIPMENT IS BEING REMOVED.
A5 EXISTING EXPOSED CONCRETE FLOORING TO REMAIN.
REV DATE DESCRIPTION
3 03/13/26 BID PACK 2 - BIDS &PERMITS
4 Date 4 BID PACK 2 - ADDENDUM 1
SCALE : 1" = 1'-0"
PARTITION JAMB DTL
099123 - INTERIOR PAINTING:
A. BASIS OF DESIGN MANUFACTURER: SHERWIN WILLIAMS. ALSO ACCEPTABLE: BENJAMIN
MOORE AND PPG PAINTS.
B. PREPARATION OF SURFACES TO RECEIVE PAINT: CLEAN, DRY, DULL, AND SOUND.
C. PAINT SYSTEMS:
a. GYPSUM BOARD AND PLASTER:
• PRIMER: PROMAR 200 ZERO VOC INTERIOR LATEX PRIMER, B28W2600
1. 4.0 MILS WET, 1.0 MILS DRY.
• INTERMEDIATE COAT: MATCH TOPCOAT.
• TOPCOAT: PROMAR 200 ZERO VOC INTERIOR LATEX EG-SHEL, B20-2600 SERIES.
1. 4.0 MILS WET, 1.6 MILS DRY.
b. GYPSUM BOARD AND PLASTER CEILING:
• PRIMER: LOXON CONCRETE & MASONRY PRIMER AS NEEDED ON NEW PLASTER
• INTERMEDIATE COAT: MATCH TOPCOAT
• TOPCOAT: PRO INDUSTRIAL WATERBORNE ACRYLIC DRY FALL, FLAT, B42-80 SERIES
c. CMU:
• PRIMER: EXTREME BOND PRIMER, B51 SERIES
1. 3.1 MILS WET, .9 MILS DRY.
• ADHESION TEST: USE PRINCIPLES OF ASTM D3359 AFTER MINIMUM 7 DAY CURE TIME
OF PRIMER TO ENSURE 90% OF COATING CONTINUES TO ADHERE, CONTACT
COATINGS MANUFACTURER FOR ASSISTANCE AS NEEDED.
• INTERMEDIATE COAT: MATCH TOPCOAT.
• TOPCOAT: PRO INDUSTRIAL PRE-CAT EPOXY EG-SHEL, K45-2150 SERIES.
1. 4.0 MILS WET, 1.6 MILS DRY PER COAT.
d. HOLLOW METAL FRAMES AND DOORS:
• PRIMER: PRO INDUSTRIAL PRO CRYL UNIVERSAL PRIMER, B66-310 SERIES.
1. 5.0 TO 10 MILS WET, 2.0 TO 4.0 MILS DRY.
• INTERMEDIATE COAT: MATCH TOPCOAT.
• TOPCOAT: PRO INDUSTRIAL ACRYLIC SEMI-GLOSS COAT, B66-650 SERIES.
1. 2.5 TO 4.0 MILS DRY PER COAT.
e. WOOD:
• PRIMER: PREMIUM WALL & WOOD PRIMER.
• INTERMEDIATE COAT: MATCH TOPCOAT.
• TOPCOAT: PRO INDUSTRIAL ACRYLIC SEMI-GLOSS COAT, B66-650 SERIES.
f. ACOUSTIC/TECTUM DECK
• PRO INDUSTRIAL WATERBORNE ACRYLIC DRY FALL, FLAT, B42-80 SERIES. UP TO 6
COATS, SPRAY APPLIED.
1. 3.5 TO 5.0 MILS WET, 1.5 TO 2.0 MILS DRY PER COAT.
D. COLORS: REFER TO BASIS OF DESIGN.
SPECIFICATIONS
SYMBOL NOTES:
1. "AC" DENOTES ABOVE COUNTER. COORDINATE HEIGHT WITH ARCHITECT.
2. "H" DENOTES HORIZONTAL MOUNTING OF DEVICE.
3. "B" DENOTES MOUNTED IN BASE.
4. "F" DENOTES MOUNTED IN FACE OF CABINETS.
D
S
SECURITY INTERCOM
SECURITY DOOR CONTACT
CEILING SPEAKER
AUDIO ONLY ALARM
VISUAL ONLY ALARM
FIRE ALARM CONTROL RELAY
REMOTE ALARM KEY TEST SWITCH
WATER FLOW SWITCH
O,S,&Y TAMPER SWITCH
HEAT DETECTOR
DUCT SMOKE DETECTOR
AREA SMOKE DETECTOR-PHOTOELECTRIC
FIRE ALARM PULL STATION
CEILING SPEAKER
SPEAKER/STROBE LIGHT
LMTG. HT. TO CDESCRIPTIONSYMBOL
SYSTEMS SYMBOL LEGEND
FIRE ALARM ANNUNCIATOR PANEL
FIRE ALARM CONTROL PANEL
F
CO
CR
FS
D
TS
RT
F.A.A.
F.A.C.P.
F.A. NOTES:
1. MATCH EXISTING SYSTEM.
SECURITY DOOR REQUEST TO EXIT
CO
R CARD READER
MAGNETIC DOOR HOLD OPENDH
CARBON MONOXIDE SENSOR. E.C TO ROUGH-IN SINGLE
GANG BOX AND 1/2"C. TO ACCESSIBLE CEILING SPACE.
46"
80"
80"
46"
46"
AT DOOR HEAD
46"
AT DOOR HEAD
TYPICALLY CLG
MOUNTED
SMOKE/HORN BASE
CO-DENOTES COMBO CARBON MONOXIDE/SMOKE
I
C
X
H
FIRE/SMOKE DAMPER
BEAM DETECTOR
F/SD
BD ---
SECURITY CAMERA - "W" DENOTES WALL MOUNTED
CHEVRON INDICATES AIM LINE
WP FIRE ALARM HORN/STROBE LIGHT
(WP-DENOTES WEATHER PROOF)
T THERMOSTAT. E.C TO ROUGH-IN SINGLE GANG BOX AND
1/2"C. TO ACCESSIBLE CEILING SPACE.
TRANSFORMER
SURFACE OR FLUSH MTD. BRANCH CIRCUIT PANELBOARD
THREE PHASE ELECTRIC MOTOR
SINGLE PHASE ELECTRIC MOTOR
MAGNETIC MOTOR STARTER-MS
DIMMER SWITCH
46"
KEY OPERATED SWITCH-SPEC. GRADE
FOUR WAY SWITCH-SPEC. GRADE
T
F
P
F
J
ELECTRICAL SYMBOL LEGEND
S
S
S
WR
D
K
S
SYMBOL DESCRIPTION
MTG. HT. TO CL
SPECIAL OUTLET-CHARACTERISTICS AS NOTED ON PLANS
FLOOR BOX 1 RECEPT, 1 DATA - THOMAS & BETTS-# 664-SC
1-1/4"C TO FLOORBOX FOR DATA
FLOOR BOX 2 RECEPT, 2 DATA THOMAS & BETTS-# 665-SC
1-1/4"C TO FLOORBOX FOR DATA
OS
IRDS IR SWITCH DIMMABLE
OCCUPANCY SENSOR
PUSH BUTTONPB
TV
IRS IR SWITCH
CS CONTROL STATION
C
SPECIAL SINGLE RECEPTACLE
VARIABLE FREQUENCY DRIVEVFD
PC PHOTO CELL
46"
46"
46"
46"
46"
46"
18"
18"
18"
18"
18"
AS NOTED
18"
46"
46"
46"
AT EQUIP.
AS NOTED
AS NOTED
46"
46"
46"
46"
72" TO TOP
18"
SINGLE POLE OR 3-WAY SWITCH-
SPECIFICATION GRADE
SPLIT WIRED RECEPTACLE
C - DENOTES CONTROLLED VIA RELAY OR OCC SENSOR
WATER RESISTANT GROUND FAULT CIRCUIT INTERRUPTER
WR-DENOTES WEATHERPROOF WHILE IN USE COVER
DUPLEX OUTLET-SPEC. GRADE
CIRCLE AROUND SYMBOL= CEILING MOUNTED
DATA OUTLET-4" SQ. BOX W/ 1 GANG RAISED COVER.
1-1/4"C. UP WALL TO CLG. SPACE
CIRCLE AROUND SYMBOL= CEILING MOUNTED
TV OUTLET-4" SQ. BOX W/ 1 GANG RAISED COVER.
1-1/4"C. UP WALL TO CLG. SPACE
CIRCLE AROUND SYMBOL= CEILING MOUNTED
JUNCTION BOX - HUBBELL NSAV62M WITH RECEPTACLE KIT
HUBBELL NSOKP. PROVIDE CONNECTOR PLATE FOR A/V
JUNCTION BOX -4" SQ. BOX W/ 2 GANG RAISED COVER.
1"C. UP WALL TO CLG. SPACE UNLESS OTHERWISE NOTED
FUSED DISCONNECT SWITCH-
FDS-HEAVY DUTY
NON-FUSED DISCONNECT SWITCH-
NFDS-HEAVY DUTY
SW. AND PLUGFUSE HOLDER- BUSSMANN
"SSU" & FUSESTAT FUSE
COMBINATION MAG. STARTER/ FUSED DISC. SWITCH - CS/FDS
COMBINATION MAG. STARTER/NON-FUSED DISC.
SWITCH - CS/NFDS
(2) DUPLEX OUTLET-SPEC. GRADE
CIRCLE AROUND SYMBOL= CEILING MOUNTED
S
PARTIALLY SHADED LUMINAIRE OR WITH "E" SUFFIX ARE
EMERGENCY
BATTERY EMERGENCY LUMINAIRE
REMOTE EMERGENCY HEAD
RECESSED LUMINAIRE 2'x4' OR 2'x2'
RECESSED WALLWASH LUMINAIRE
RECESSED DOWNLIGHT LUMINAIRE
LED ACCENT/UNDER CABINET LUMINAIRE
TRACK LIGHTING LUMINAIRE
SURFACE LUMINAIRE
WALL MOUNTED LUMINAIRE
PENDANT LUMINAIRE
SITE LIGHTING LUMINAIRE
NIGHT LIGHT
STRIP LUMINAIRE
SURFACE LUMINAIRE 2'x4' OR 2'x2'
EXIT SIGN - WALL MOUNTED OR CEILING MOUNTED
ARROWS INDICATE PATH OF EGRESS
NL
EE
H HUMIDISTAT. E.C TO ROUGH-IN SINGLE GANG BOX AND
1/2"C. TO ACCESSIBLE CEILING SPACE. 46"
WN ---
PS SWITCH WITH PILOT LIGHT 46"
18"TELEPHONE OUTLET-4" SQ. BOX W/ 1 GANG RAISED
COVER. 1-1/4"C. UP WALL TO CLG. SPACE
18"TELEPHONE/DATA OUTLET-4" SQ. BOX W/ 1 GANG
RAISED COVER. 1-1/4"C. UP WALL TO CLG. SPACE
M ---ELECTRIC UTILITY METER
P ---POWER POLE - SEE DRAWING FOR POWER -
POWER/DATA SPECIFICATIONS
DS DAYLIGHT SENSOR ---
MS MANUAL MOTOR STARTER SWITCH 46"
ELECTRICAL IDENTIFICATION
N.T.S.
FRONT
REAR SIDE
OF PLATE
FRONT
REAR SIDE OF
PLATE
BPA-15LP2-5
LABEL CKT. NO. OF EACH DEVICE ON REAR
SIDE OF COVER PLATE. USE PERMANENT
MARKER PEN, BRADY MARKING SYSTEM OR
OTHER METHOD APPROVED BY THE ENGINEER
JUNCTION BOXES (EXPOSED
OR CONCEALED ABOVE
ACCESSIBLE CEILING)
LABEL COVERS WITH CKT.'S CONTAINED
WITHIN. USE PERMANENT MARKER PEN
OR OTHER APPROVED METHOD.
FOR J.B.'S CONTAINING OTHER
THAN POWER OR LIGHTING CKT.'S
LABEL COVERS INDICATING
SYSTEM TYPE AND ZONES.
CKT.S
LP4-13,15,17
DUPLEX RECEPTACLE
PLATE
STANDARD TOGGLE
SWITCH PLATE
LABEL EXAMPLES:
"FIRE ALARM-ZONES 2&3"
"P.A. ZONES 4,5,&6" "DATA
CIRCUITS A&B" "EXIT
SIGNS-EMI&2" "EMERG.
CKTS. BPEM-3,4"
E100 A-1
PP POWER PACK ---
EV ---EV CHARGER
F= FUTURE
WIRELESS ROUTER
CIRCLE AROUND SYMBOL= CEILING MOUNTED
SURFACE MOUNT KITCHEN FLOOR BOX DETAIL
N.T.S.
SIMILAR TO HUBBELL SA6685G-2G U.O.N.
DEVICE BOX W/20A-120V DUPLEX RECEPTACLE.
NOTE: FOR 50A,240V PROVIDE HUBBELL
SA6685-4G WITH NEMA 14-50R. COORDINATE
WITH EQUIPMENT.
FLOOR
3/4" RIGID CONDUIT
3/4" DROP
E1.00 A-2
E100
DETAILS, SYMBOL
LEGENDS &
SPECIFICATIONS
1/
/2
4:
:5
P
M
EBERSOLE CENTER FOOD
SERVICE - EQUIPMENT
REPLACEMENT &
3400 2ND STREET
WAYLAND, MI 49348
26000750A
REV DATE DESCRIPTION
Colliers Engineering & Design, Architecture, Landscape Architecture, Surveying, CT P.C.
Colliers
Engineering & Design
Colliers
Engineering & Design
GRAND RAPIDS
560 5th St. NW
Suite 305 Grand Rapids, MI 49504
Phone: 616.827.4270
PROJECT MANAGER:
DESIGNER: REVIEWER:
DISCIPLINE LEAD:
DRAWING NUMBER:
DATE ISSUED: PROJECT NUMBER:
SHEET NAME:
www.colliersengineering.com
NOTE: DO NOT SCALE DRAWING FOR CONSTRUCTION.
MI ARCHITECTURE
FIRM LICENSE # NLP000605
Copyright © 2024. Colliers Engineering & Design All Rights Reserved. This drawing and all the information contained herein is authorized for use only by the party for whom the services were contracted or to whom it is certified. This drawing may not be copied, reused, disclosed, distributed or relied upon for any other purpose without the express written consent of Colliers Engineering & Design.
BID PACK 2
DATE DESCRIPTION
100 Cesar E Chavez Ave SW Grand Rapids, Michigan 49503
(616) 742-2810 www.classicengineering.com Project # 2026021
Classic Engineering, LLC
03/16/2026
1 03/16/26 BID PACK 2 - BIDS & PERMITS
2 03/XX/26 BULLETIN #1
LANSING SCHOOL
DISTRICT
3 04/03/26 BID PACK 2 - ADDENDUM 1
RENOVATIONS SO-1853
P :\2
6\
LS
D
E be rs ol e C af et er ia
\W or ki ng
D ra w in gs \2
E
2.
dw g, /3 /2
9:
:5
A M
, m de lo ra
COOLER
1009B
WALK-IN
FREEZER
MULTI-PORPOSE
ROOM
KITCHEN
SERVING
DISHWASHING
STORAGE
WC
A A A A A A A A A A
A A A A A A A A A A
A A A A A A A A A A
A A A A A A A A A A
EM
EM
EM EM
EM
EM
E1 E
E1E E1 E
E1 E
E1 E
E1 EE1E
B B
B
B
B
B
B
B
B
B
B
B
B B
B B
1 1
2 2
C C C
OS
OS C
E1E
B B B
B B B B B B
B B B
3 3
EX. EX.
EX.EX.
EM
E1 E
4 4
4 4
1009A
WALK-IN
COOLER
1009B
WALK-IN
FREEZER
MULTI-PORPOSE
ROOM
KITCHEN
SERVING
DISHWASHING
STORAGE
WC
1.2
1.6
1.7
1.5
1.5
1.9
2.0
1.6
1.4
2.6
3.8
3.0
1.9
2.0
3.3
5.0
4.0
2.2
4.2
3.7
1.9
1.8
3.2
5.5
4.6
2.5
3.5
4.1
2.4
1.4
1.4
2.0
3.1
3.5
1.8
2.3
2.2
1.4
1.0
1.0
1.3
1.6
1.9
0.9
5.6
0.4
0.4
0.4
0.3
0.3
0.5
0.6
0.5
0.4
0.3
0.5
0.7
0.8
0.6
0.4
0.5
0.7
0.9
0.7
0.5
0.4
0.6
0.8
0.7
0.5
0.3
0.4
0.6
0.6
0.4
0.3
0.3
0.3 0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.5
0.6
0.6
0.4
0.5
0.7
0.9
0.9
0.6
0.7
1.0
1.2
1.1
0.8
1.1
1.3
1.4
1.2
1.0
1.7
1.6
1.5
1.4
1.4
2.7
2.4
2.0
2.3
2.3
4.0
3.9
2.9
3.8
3.9
5.3
3.8
5.6
5.3
4.8
5.2
3.9
5.3
5.0
2.4
2.9
2.8
3.0
2.6
1.3
1.6
1.7
1.6
1.4
0.2
0.2
0.2
0.2
0.2
0.2
5.7
0.4
0.5
0.7
0.9
1.3
1.5
1.3
1.1
1.0
0.8
0.7
0.5
0.6
0.8
1.1
1.7
2.2
1.9
1.6
1.3
1.0
0.8
0.7
0.5
0.8
1.1
1.7
2.5
2.7
2.2
1.7
1.3
1.1
0.9
0.6
0.5
1.0
1.4
1.9
2.2
2.2
1.8
1.3
1.1
1.0
0.9
0.7
0.5
1.3
1.6
1.9
1.7
1.4
1.1
1.0
0.9
1.0
1.0
0.8
0.6
1.6
2.7
3.2
2.3
1.5
1.0
0.8
0.8
0.9
1.1
1.0
0.7
1.8
4.0
3.9
2.2
1.1
0.8
0.7
0.7
0.9
0.9
0.7
1.3
2.8
4.3
3.5
2.3
1.3
0.8
0.6
0.6
0.7
0.7
0.5
0.8
1.4
2.1
2.4
1.7
1.2
0.8
0.7
0.6
0.5
0.4
0.3
0.5
0.8
1.0
1.2
1.2
1.0
0.9
0.9
0.8
0.7
0.4
0.3
0.4
0.5
0.7
0.8
0.8
0.9
1.0
1.1
1.0
0.8
0.4
0.3
0.3
0.4
0.5
0.6
0.7
0.8
0.9
0.9
0.8
0.6
0.4
0.2
5.4
1.9
1.9
1.8
1.8
1.6
1.4
1.1
0.9
0.9
0.6
0.4
2.1
0.6
0.7
0.7
0.7
0.4
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.4
0.4
0.5
0.6
0.9
1.2
1.6
1.6
1.3
1.1
1.0
1.0
0.9
0.8
0.6
0.5
0.5
0.5
0.8
1.0
1.0
0.8
0.5
0.3
0.4
0.6
0.7
0.6
0.6
0.5
0.5
0.5
0.6
0.9
1.4
2.6
3.9
3.1
1.7
1.3
1.4
1.6
1.6
1.3
1.0
0.7
0.6
0.6
0.8
0.9
0.8
0.6
0.4
0.4
0.5
0.8
1.0
1.0
0.8
0.7
0.6
0.7
0.8
1.1
2.1
4.1
3.7
1.7
1.2
1.4
2.0
2.6
2.4
1.7
1.2
0.8
0.7
0.6
0.6
0.6
0.5
0.4
0.4
0.5
0.8
1.2
1.3
1.1
0.9
0.8
0.8
0.9
1.3
2.3
3.3
3.9
2.3
1.3
1.0
1.2
1.7
2.6
2.5
2.0
1.5
1.1
0.8
0.5
0.5
0.5
0.4
0.4
0.5
0.6
0.9
1.2
1.3
1.3
1.1
1.0
0.9
1.0
1.2
1.6
2.2
2.0
1.3
0.9
0.8
1.0
1.3
1.8
2.1
1.8
1.5
1.2
0.9
0.4
0.4
0.5
0.5
0.6
0.7
0.9
1.0
1.2
1.3
1.3
1.3
1.2
1.0
1.0
1.0
1.2
1.2
1.1
0.9
0.8
0.8
0.9
1.0
1.3
1.5
1.6
1.4
1.1
0.9
0.4
0.5
0.5
0.7
0.9
1.2
1.3
1.3
1.3
1.4
1.4
1.5
1.5
1.2
1.0
1.0
0.9
0.9
0.8
0.7
0.7
0.8
0.9
1.0
1.0
1.1
1.2
1.2
1.0
0.9
0.5
0.6
0.8
1.1
1.7
1.9
1.7
1.5
1.4
1.5
1.6
1.7
1.8
1.5
1.2
0.9
0.8
0.8
0.7
0.7
0.8
0.9
1.0
1.0
1.0
1.0
1.0
1.0
0.9
0.8
0.6
0.8
1.2
1.8
2.6
2.4
1.9
1.6
1.4
1.5
1.8
2.0
2.1
1.9
1.4
1.0
0.8
0.8
0.8
0.8
0.9
1.1
1.1
1.0
1.0
0.9
0.9
0.8
0.8
0.8
0.8
1.1
1.6
2.2
2.6
2.3
1.8
1.4
1.2
1.3
1.7
2.2
2.4
2.3
1.6
1.1
0.9
0.8
0.8
0.9
1.1
1.2
1.2
1.1
1.0
0.9
0.8
0.7
0.7
0.7
0.9
1.2
1.5
1.7
1.7
1.5
1.3
1.1
1.0
1.1
1.5
2.2
2.5
2.4
1.7
1.2
0.9
0.9
0.9
1.1
1.3
1.3
1.2
1.1
1.0
0.8
0.7
0.6
0.6
0.6
0.9
1.2
1.4
1.5
1.4
1.2
1.1
1.0
0.9
1.0
1.2
1.7
2.1
2.0
1.5
1.2
1.0
0.9
1.0
1.1
1.3
1.3
1.2
1.0
0.8
0.7
0.6
0.6
0.5
0.5
1.2
1.7
1.8
1.6
1.4
1.2
1.1
1.0
1.0
1.1
1.3
1.5
1.5
1.3
1.1
1.0
0.9
1.0
1.1
1.1
1.0
0.9
0.8
0.7
0.6
0.6
0.5
0.5
0.5
1.8
2.5
2.8
2.3
1.8
1.5
1.2
1.1
1.1
1.1
1.2
1.2
1.1
1.0
1.0
0.9
1.0
0.9
0.9
0.8
0.8
0.7
0.6
0.6
0.5
0.5
0.5
0.5
2.7
3.1
2.9
2.5
2.0
1.6
1.3
1.2
1.1
1.1
1.1
1.1
1.0
1.0
0.9
0.9
0.9
0.8
0.8
0.7
0.6
0.6
0.5
0.5
0.5
0.5
0.5
0.3
2.3
3.3
3.3
2.8
2.2
1.8
1.5
1.4
1.3
1.2
1.1
1.1
1.0
1.0
0.9
0.9
0.9
0.8
0.8
0.7
0.7
0.6
0.5
0.5
0.5
0.5
0.5
1.2
1.8
3.5
3.4
2.8
2.3
1.9
1.7
1.6
1.6
1.5
1.3
1.0
1.0
0.9
0.9
0.9
0.9
1.0
0.9
0.9
0.8
0.7
0.6
0.6
0.5
0.5
0.5
1.0
1.6
2.2
2.7
3.0
2.5
2.1
1.9
1.9
2.2
2.2
1.9
1.4
1.0
0.9
0.9
0.9
1.0
1.0
1.1
1.2
1.1
1.0
0.9
0.7
0.6
0.6
0.5
0.5
0.9
1.2
1.5
1.7
1.7
1.9
1.7
1.7
1.8
2.1
2.5
2.6
2.2
1.4
1.0
0.8
0.8
0.8
0.9
1.0
1.2
1.3
1.2
1.1
1.0
0.8
0.7
0.7
0.6
0.6
0.9
1.2
1.4
1.5
1.4
1.2
1.4
1.5
1.8
2.1
2.3
2.4
2.0
1.2
0.9
0.8
0.7
0.8
0.8
1.0
1.1
1.3
1.2
1.1
1.0
0.9
0.8
0.7
0.7
0.7
0.9
1.2
1.6
1.8
1.6
1.4
1.2
1.4
1.6
1.8
2.0
1.9
1.5
1.0
0.8
0.7
0.7
0.7
0.8
0.9
1.0
1.1
1.1
1.1
1.0
0.9
0.9
0.8
0.8
0.7
0.7
1.2
1.8
2.5
2.6
2.0
1.5
1.4
1.4
1.5
1.6
1.4
1.1
0.8
0.7
0.7
0.7
0.7
0.8
0.8
0.8
0.9
1.0
1.0
1.0
1.0
1.0
0.9
0.8
0.8
0.6
0.9
1.4
2.3
2.6
2.1
1.7
1.4
1.3
1.3
1.2
1.1
0.9
0.7
0.7
0.7
0.7
0.8
0.9
0.9
0.9
0.8
0.9
0.9
1.0
1.1
1.1
1.0
0.9
0.8
0.5
0.7
1.0
1.5
2.0
1.8
1.6
1.4
1.3
1.2
1.1
0.9
0.8
0.7
0.6
0.7
0.8
1.0
1.2
1.3
1.0
0.9
0.9
0.9
1.2
1.4
1.4
1.2
1.0
0.9
0.5
0.6
0.7
0.9
1.2
1.4
1.3
1.3
1.2
1.2
1.1
0.9
0.7
0.6
0.6
0.6
0.9
1.4
2.0
2.2
1.5
1.1
1.0
1.2
1.7
1.8
1.6
1.3
1.1
0.9
0.5
0.6
0.6
0.7
0.8
0.9
1.1
1.1
1.2
1.3
1.2
0.9
0.7
0.6
0.6
0.6
0.9
1.8
3.1
3.7
2.4
1.4
1.3
1.7
2.4
2.2
1.8
1.3
1.0
0.8
0.7
0.7
0.7
0.7
0.6
0.6
0.8
1.1
1.3
1.3
1.0
0.8
0.6
0.5
0.5
0.6
0.8
1.8
3.9
5.2
3.6
1.8
1.6
2.1
2.8
2.4
1.6
1.1
0.8
0.6
0.8
0.9
0.9
0.8
0.6
0.5
0.6
0.9
1.1
1.0
0.8
0.6
0.5
0.5
0.4
0.5
0.7
1.2
2.9
5.0
3.3
1.9
1.6
2.0
2.2
1.7
1.1
0.8
0.6
0.6
0.8
1.0
1.0
0.9
0.6
0.4
0.4
0.6
0.8
0.7
0.6
0.5
0.4
0.4
0.4
0.4
0.5
0.8
1.4
2.2
2.2
1.5
1.4
1.5
1.3
1.0
0.8
0.6
0.5
0.5
0.6
0.7
0.8
0.7
0.5
0.3
0.3
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.6
0.8
1.0
1.2
1.1
1.0
0.9
0.8
0.6
0.5
0.4
0.4
0.4
0.2
5.4
EM1 @ 7.5'
E1 @ 7.5'
E1 @ 7.5'
E1 @ 7.5'
EM1 @ 7.5'
E1 @ 7.5' E1 @ 7.5'
EM1 @ 7.5' EM1 @ 7.5'
EM1 @ 7.5'EM1 @ 7.5'
EM1 @ 12'EM1 @ 12'
EM1 @ 7.5'
Statistics
Description Symbol Avg Max Min Max/Min Avg/Min
MECH 12 2.5 fc 5.6 fc 0.9 fc 6.2:1 2.8:1 MULTI-PURPOSE 8 1.2 fc 5.4 fc 0.2 fc 27.0:1 6.0:1 SERVING 1.5 fc 5.7 fc 0.2 fc 28.5:1 7.5:1 VESTIBULE 3 1.4 fc 2.1 fc 0.4 fc 5.3:1 3.5:1 KITCHEN 3 1.2 fc 5.4 fc 0.2 fc 27.0:1 6.0:1
Schedule
Symbol Label Image QTY Manufacturer Catalog Description Number Lamps
Lamp Output LLF Input
Power Polar Plot
E1
5 Lithonia Lighting LHQM LED QUANTUM LED EMERGENCY COMBO (ONE
HEAD ONLY)
1 Absolute 1 1.5
EM1
9 Lithonia Lighting ELM4L ELM4L SP640L 1 345 1 2.5
EL101
FIRST FLOOR PLAN -
LIGHTING /
PHOTOMETRICS
1/
/2
4:
:5
P
M
EBERSOLE CENTER FOOD
SERVICE - EQUIPMENT
REPLACEMENT &
3400 2ND STREET
WAYLAND, MI 49348
26000750A
REV DATE DESCRIPTION
Colliers Engineering & Design, Architecture, Landscape Architecture, Surveying, CT P.C.
Colliers
Engineering & Design
Colliers
Engineering & Design
GRAND RAPIDS
560 5th St. NW
Suite 305 Grand Rapids, MI 49504
Phone: 616.827.4270
PROJECT MANAGER:
DESIGNER: REVIEWER:
DISCIPLINE LEAD:
DRAWING NUMBER:
DATE ISSUED: PROJECT NUMBER:
SHEET NAME:
www.colliersengineering.com
NOTE: DO NOT SCALE DRAWING FOR CONSTRUCTION.
MI ARCHITECTURE
FIRM LICENSE # NLP000605
Copyright © 2024. Colliers Engineering & Design All Rights Reserved. This drawing and all the information contained herein is authorized for use only by the party for whom the services were contracted or to whom it is certified. This drawing may not be copied, reused, disclosed, distributed or relied upon for any other purpose without the express written consent of Colliers Engineering & Design.
BID PACK 2
DATE DESCRIPTION
100 Cesar E Chavez Ave SW Grand Rapids, Michigan 49503
(616) 742-2810 www.classicengineering.com Project # 2026021
Classic Engineering, LLC
03/16/2026
1 03/16/26 BID PACK 2 - BIDS & PERMITS
2 03/XX/26 BULLETIN #1
LANSING SCHOOL
DISTRICT
3 04/03/26 BID PACK 2 - ADDENDUM 1
RENOVATIONS SO-1853
SCALE: 1/8" = 1'-0"
GENERAL LIGHTING NOTES:
1. CONNECT EMERGENCY LIGHTING TO CIRCUIT FEEDING GENERAL LIGHTING IN THAT AREA.
2. EXIT SIGNS TO BE CONNECTED TO UNSWITCHED LIGHTING CIRCUIT OR EMERGENCY LIGHTING
CIRCUIT FEEDING THAT AREA.
3. LIGHTING CONTROL SHALL COMPLY WITH 2021 MICHIGAN ENERGY CODE WHERE APPLICABLE.
4. ALL LIGHTING CIRCUITS WITHIN DWELLINGS TO BE PROTECTED WITH AFCI CIRCUIT BREAKERS.
LIGHTING KEY NOTES:
NO WORK IN THIS AREA.
REPLACE EXISTING LIGHTS ONE-FOR-ONE WITH NEW LED FIXTURES, REFER TO FIXTURE SCHEDULE
ON SHEET E100.
EXISTING PADDLE FANS AND CONTROL TO REMAIN.
REUSE EXISTING SWITCHES FOR NEW LIGHTS UNLESS SHOWN TO BE CONTROLLED WITH
OCCUPANCY SENSOR.
REPLACE EXISTING LIGHTS UNDER HOOD ONE FOR ONE. FIELD VERIFY EXACT SIZE AND COUNTS OF
FIXTURES.
SCALE: 1/8" = 1'-0"
L. WOOD
C. LADEWIG
C. LADEWIG
P :\2
6\
LS
D
E be rs ol e C af et er ia
\W or ki ng
D ra w in gs \2
E
1.
dw g, /3 /2
9:
:5
A M
, m de
COOLER
1009B
WALK-IN
FREEZER
MULTI-PORPOSE
ROOM
KITCHEN
SERVING
DISHWASHING
STORAGE
WC
EX. PANEL
EBPC-02
EX. PANEL
EBPC-03
EX. CEILING FAN EX. CEILING FAN
EX. CEILING FAN EX. CEILING FAN
502A
EX. PANEL MDP
EX. PANEL LP-A
EX. PANEL PP-B
EX EX EX EX
EX
E
EXEX. AC
EX
EX
3 EBCP03-10
EBCP03-2/4
EBCP03-6
EBCP03-8
EQUIPMENT SCHEDULE
Item EQUIPMENT DESCRIPTION VOLTS PH
AMPS
LOAD
DIRECT
BY EC
CORDSET
BY FSEC AFF (in) REMARKS
102 ICE MAKER W/ BIN 208 1 5.9 X 72
301 STEAMER & STAND 208 3 42.0 X
302 CONVECTION OVEN - DOUBLE DECK 208 3 34.0
401 HOT FOOD TABLE 120/208 1 28.4 X 5 PEDESTAL MOUNTED RECEPTACLE BY TRADES
403 COLD FOOD TABLE 120 1 8.6 X 5
405 MILK COOLER - DOUBLE SIDED 120 1 3.3 X 5
502 DISHWASHER
502A DRAIN WATER TEMPERING KIT 120 1 5.0 X 16
PEDESTAL MOUNTED RECEPTACLE BY TRADES
PEDESTAL MOUNTED RECEPTACLE BY TRADES
5 PEDESTAL MOUNTED JUNCTION BOX BY TRADES
5 PEDESTAL MOUNTED RECEPTACLE BY TRADES
208 3 138.9
X
60X
BY TRADES AND STORED OR DISCARDED BY THE FSEC
FOR CONSTRUCTION PURPOSES.
AS DIRECTED BY OWNER.
ANY EXISTING EQUIPMENT AS REQUIRED
EQUIPMENT NOT BEING REUSED TO BE DISCONNECTED
RELOCATED BY THE FSEC AS PER PLANS AND SPECIFICATIONS.
BE DISCONNECTED BY THE TRADES AND
EQUIPMENT DESIGNATED AS RELOCATED SHALL5.
4.
WHERE APPLICABLE.
FSEC SHALL VERIFY ROUGHIN REQUIREMENTS FOR
TRADES TO REUSE EXISTING ROUGHINS
FUTURE, PURVEYOR SUPPLIED, OWNERS RELOCATED
EQUIPMENT, OWNER SUPPLIED EQUIPMENT, ETC.
TRADES SHALL DISCONNECT, REMOVE, STORE & RECONNECT
2.
3.
NOTE:
1.
EP101
FIRST FLOOR PLAN -
POWER
1/
/2
4:
:5
P
M
EBERSOLE CENTER FOOD
SERVICE - EQUIPMENT
REPLACEMENT &
3400 2ND STREET
WAYLAND, MI 49348
26000750A
REV DATE DESCRIPTION
Colliers Engineering & Design, Architecture, Landscape Architecture, Surveying, CT P.C.
Colliers
Engineering & Design
Colliers
Engineering & Design
GRAND RAPIDS
560 5th St. NW
Suite 305 Grand Rapids, MI 49504
Phone: 616.827.4270
PROJECT MANAGER:
DESIGNER: REVIEWER:
DISCIPLINE LEAD:
DRAWING NUMBER:
DATE ISSUED: PROJECT NUMBER:
SHEET NAME:
www.colliersengineering.com
NOTE: DO NOT SCALE DRAWING FOR CONSTRUCTION.
MI ARCHITECTURE
FIRM LICENSE # NLP000605
Copyright © 2024. Colliers Engineering & Design All Rights Reserved. This drawing and all the information contained herein is authorized for use only by the party for whom the services were contracted or to whom it is certified. This drawing may not be copied, reused, disclosed, distributed or relied upon for any other purpose without the express written consent of Colliers Engineering & Design.
BID PACK 2
DATE DESCRIPTION
100 Cesar E Chavez Ave SW Grand Rapids, Michigan 49503
(616) 742-2810 www.classicengineering.com Project # 2026021
Classic Engineering, LLC
03/16/2026
1 03/16/26 BID PACK 2 - BIDS & PERMITS
2 03/XX/26 BULLETIN #1
LANSING SCHOOL
DISTRICT
3 04/03/26 BID PACK 2 - ADDENDUM 1
RENOVATIONS SO-1853
NO WORK IN THIS AREA.
PROVIDE NEW WIRING DEVICES IN MULTI-PURPOSE ROOM WITH TAMPER RESISTANT AND
STAINLESS STEEL COVER PLATES AS SHOWN ON PLAN.
ROUTE CIRCUITS FOR SERVING LINE DOWN INSIDE THE COLUMN TO FLOOR AREA. PROVIDE
SURFACE MOUNTED CONDUIT ON FLOOR TO SURFACE MOUNTED BOXES AS SHOWN ON PLAN.
ELECTRICAL CONTRACTOR SHALL PROVIDE A RUBBER RAMP TO COVER THE CONDUITS EQUAL
TO "RUBBER FORM" #RF-RPIF. RUN CONTINUOUS BETWEEN BOXES.
PROVIDE 1" CONDUIT DROP WITH 3-#8 + GROUND AND FLOOR MOUNTED KEYSTONE STYLE
FLOOR BOX WITH 240V/20A NEMA 14/50 RECEPTACLE. VERIFY WITH EQUIPMENT.
REUSE EXISTING CIRCUIT, RECONNECT TO NEW EQUIPMENT, FIELD VERIFY.
PROVIDE GFCI CIRCUIT BREAKER.
PROVIDE NEW CIRCUIT FOR DISHWASHER AND DRAIN TEMPERING KIT.
PROVIDE 3/4" CONDUIT DROP WITH 2-#12 + GROUND TO FLOOR MOUNTED KEYSTONE STYLE
FLOOR BOX WITH 120V/20A NEMA 5-20 RECEPTACLE.
SCALE: 1/8" = 1'-0"
POWER KEYNOTES: GENERAL POWER NOTES:
1. ALL EXISTING 15A & 20A 120V NON-LOCKING RECEPTACLES WITH PUBLIC SPACES WHERE
CHILDREN CAN BE FOUND SHALL BE LISTED TAMPER RESISTANT PER NEC 406.12. THIS
INCLUDES SCHOOLS CORRIDORS, GYM, MUSIC ETC. PROVIDE STAINLESS STEEL COVER
PLATES.
2. MOUNT PANELS, TRANSFORMERS, DISCONNECT SWITCHES, AND COMBINATION MOTOR
STARTERS WITH ADEQUATE CLEARANCES IN ACCORDANCE WITH NEC 110.
3. VERIFY ALL EQUIPMENT REQUIREMENTS, CONNECTION TYPES, AND LOCATIONS WITH
EQUIPMENT SUPPLIER AND NAMEPLATES PRIOR TO ROUGH-IN.
4. FIRE ALARM DEVICES SHOWN FOR REFERENCE ONLY AND DO NOT REPRESENT
COMPREHENSIVE SYSTEMS. ANY NEW DEVICES TO BE ADDED, MATCH EXISTING SYSTEM.
SYSTEM WILL BE REQUIRED TO BE RECERTIFIED.
L. WOOD
C. LADEWIG
C. LADEWIG
P :\2
6\
LS
D
E be rs ol e C af et er ia
\W or ki ng
D ra w in gs \2
E
1.
dw g, /3 /2
9:
:0
A M
, m de
LANSING SCHOOL DISTRICT
2026 SUMMER PROJECTS
KITCHEN REMODEL PROJECTS
BID PACKAGE #2
CM CLARIFICATION #1
CM CLARIFICIATION #1
1. Attwood Elementary:
A. The Tectum Panels will be an accent color and they should be painted before they are installed.
B. The exposed ceiling will be painted with SW Flat Ceiling Paint.
C. The Paint Specification is on Sheet A141.
2. Ebersole Center:
A. Painting notes are on Sheet A101.
B. Wood trim will be painted with SW Semi-Gloss, Color to match existing trim.
C. Walls and ceilings will be painted with SW Eggshell, Color to match existing.
D. The painter will not be required to provide plywood floor protection for Tectum Ceiling touch up paint.
3. Dwight Rich:
A. Paint Specification is on Sheet A101.
4. Gardner Elementary:
A. Paint Specification is on Sheet A141.
B. Any areas where masonry infill is noted will need to be primed and painted, P-1.
C. Masonry infill is located at Passage D122, Passage D124, New Cooler 130B, Dishwash Area A134 and any other location that note new masonry walls.
D. Several HM door frames require paint as noted on Sheet A141. All new doors will be factory finished.
KITCHEN REMODEL PROJECTS
BID PACKAGE #2
CM CLARIFICATION #2
CM CLARIFICIATION #2
1. General note for Attwood Elementary:
Resinous Flooring is removed from the Painting Division ‘D’ and moved to Bid Division ‘C’ Flooring.
The flooring bidders must include an allowance of $5,000.00 for nonstandard prep work.
There will be substantial prep work involved with the Attwood floor project and the flooring contractor will be expected to track the floor prep hours and collect signed T&M slips from the CM Superintendent. When the project is finished the flooring contractor must submit the slips to be billed against the allowance and a change order will be issued to cover the transaction.
2. If painters want to bid on the resinous floor work they should include voluntary alternates on the bid form for the resinous flooring at Attwood and Gardner.
KITCHEN REMODEL PROJECTS
BID PACKAGE #2
CM CLARIFICATION #3
CM CLARIFICIATION #3
1. The current Bid Division E – Mechanical has been divided into two separate divisions. Bid Division E will be “Plumbing” and Bid Division “G” will be HVAC.
2. Bid Division E – Plumbing will include:
Section 024119 Selective Demo 078400 Firestopping 220000 Plumbing
Gardner Phase 1 includes Kitchen Area only to be completed Summer of 2026.
Gardner Phase 2 will proceed in Summer 2027.
All Plumbing demolition detailed on the drawings is included in this contract.
The day these projects start the plumbing contractor must be on site to disconnect kitchen equipment so the food service contractor can remove it.
This division includes labor, material, and equipment to furnish and install all plumbing including all domestic water systems, pipes, pumps, heads, sanitary soil waste and vent systems, storm drain systems, Grease trap and vent system, plumbing fixtures and equipment, traps and supports, insulation for plumbing systems and fixture installation, pipe and valve identification for a complete and operating system as shown and/or specified.
This division includes supply and installation of all gas piping and regulators, supply and installation of stainless-steel sinks in prefabricated casework, water heaters, condensate drains and fireproof sealants where plumbing work penetrates fire rated walls and ceilings.
The plumbing plans detail several new sanitary lines that must be connected to existing UG sanitary piping.
In areas that require cutting, removal and replacement of concrete floors, the General Trades Contractor will remove and replace the concrete. The Plumbing Contractor must perform all required excavation, backfill, compaction and removal of excess dirt.
The drawings detail several new water pipes to connect to new equipment and fixtures and this piping is included in the Plumbing division.
This division includes the following prep work for the Food Service Equipment Contractor.
All required rough-ins and piping with stop valves, elbows, nipples, couplers, traps, waste vents, gas regulators for water, steam, gas, etc. and will also make final connections to the equipment. The plumber will also install all equipment accessories furnished by the FSEC. The plumber will provide the required water heater and piping unless noted otherwise and plumbing, mechanical and electrical subs shall disconnect and reconnect relocated equipment if applicable.
This division includes all required permits and fees as required by state code. Housekeeping and cleanup on a daily basis is included in this division.
KITCHEN REMODEL PROJECTS
BID PACKAGE #2
CM CLARIFICATION #3
This division includes as built drawings, operation and maintenance manuals, owner training and specified attic stock material.
Gardner Phase 1 includes all work in Kitchen Area including Rooms 130A, 134, 136 and 137.
Gardner Phase 2 includes the balance of the Plumbing work including Rooms 131, 132, 129, 133, 121 and
125.
3. Bid Division G – HVAC will include:
Section 024119 Selective Demo 078400 Firestopping
230000 HVAC
Gardner Elementary is the only school that includes HVAC work.
Gardner Phase 1 includes Kitchen Area only to be completed Summer of 2026.
Gardner Phase 2 will proceed in Summer 2027.
Any roof patching must be scheduled with the roofing company that holds the warranties for these projects.
If roof curbs are required, they must be provided with the roof top equipment. Placement of roof top equipment must be approved by the CM. If additional steel is required, the CM will arrange for supply and erection of the steel.
This division includes labor, material and equipment to make the specified revisions to the HVAC system as detailed in the contract documents. The majority of the HVAC work involves revisions to the existing ductwork, grilles, diffusers and dampers, but if the documents specify new equipment such as pumps, stacks, flues, unit heaters, air handling units, unit vents, exhaust fans or furnaces, this contractor must provide and install all of the specified equipment.
Any required connections or adjustments to the ATC / BMS system are included in this contract. All engineering, installation, calibration, software programming and start-up of the ATC / BMS system are included in this contract.
Any specified testing and balance for the HVAC systems is included in this division.
This division includes all required permits and fees as required by state code. Housekeeping and cleanup on a daily basis is included in this division.
This division includes as built drawings, operation and maintenance manuals, owner training and specified attic stock material.
Gardner Phase 1 includes all work in Kitchen Area including Rooms 130A, 134, 136 and 137.
Gardner Phase 2 includes the balance of the HVAC work including Rooms 131, 132, 129, 133, 121 and
125.