S02 - Attachment 8 - Columbia EHRM Fire Drawing Set 6 of 9.pdf

PDF 16 MB Posted

Attached to
EHRM Infrastructure Upgrades Construction - Columbia, SC VAMC Federal contract opportunity
Solicitation number
36C77623R0096
Issued by
Department of Veterans Affairs Technology Acquisition Center Austin

About this file

This file is an attachment to a solicitation for the EHRM Infrastructure Upgrades Construction project at the Columbia, South Carolina VA Medical Center. The solicitation number is 36C77623R0096 and is being conducted by the Department of Veterans Affairs Technology Acquisition Center in Austin, Texas. The attachment contains fire drawing set number 6 of 9 and is 16MB in size. Offerors will need to review all 9 drawing sets to fully understand the scope of work required for upgrades to infrastructure at the medical center, which includes construction and renovation of buildings and systems to improve energy and environmental performance. The response date and planned award date are not provided in this attachment.

View the file

Other files for this federal contract opportunity

Other files attached to EHRM Infrastructure Upgrades Construction - Columbia, SC VAMC, newest first.
File Type Posted
36C77623R0096 0003 - Extension and RFI Answers - Columbia.pdf PDF
36C77623R0096 0001 - Columbia EHRM - Extend RFI Deadline.pdf PDF
36C77623R0096 0002 - Columbia EHRM - Site Visit Sign-In and Risk Assess.pdf PDF
544 20 107 Columbia EHRM Infrastructure Risk Assessment.pdf PDF
Columbia VA EHRM Site Visit Sign-In Sheet.pdf PDF
S02 - Solicitation - 36C77623R0096 - RFP - Columbia EHRM.pdf PDF
S02 - Attachment 3 - Columbia EHRM General Drawing Set 1 of 9.pdf PDF
S02 - Attachment 6 - Columbia EHRM Arch Drawing Set 4 of 9.pdf PDF
S02 - Attachment 9 - Columbia EHRM Mechanical Drawing Set 7 of 9.pdf PDF
S02 - Attachment 10 - Columbia EHRM Electrical Drawing Set 8 of 9.pdf PDF
S02 - Attachment 12 - EHRM Columbia VAHCS Addendum 001.pdf PDF
S02 - Attachment 14 - Contractor Safety - Environmental Form.pdf PDF
S02 - Attachment 1 - Columbia EHRM Statement of Work 21Feb23.pdf PDF
S02 - Attachment 2 - Columbia EHRM Specifications - 21Feb23.pdf PDF
S02 - Attachment 4 - Columbia EHRM Civil Drawing Set 2 of 9.pdf PDF
S02 - Attachment 5 - Columbia EHRM Arch Drawing Set 3 of 9.pdf PDF
S02 - Attachment 7 - Columbia EHRM Arch Drawing Set 5 of 9.pdf PDF
S02 - Attachment 16 - Wage Rates - Richland 1.6.23.pdf PDF
S02 - Attachment 13 - Limitations on Subcontracting - Construction.pdf PDF
S02 - Attachment 11 - Columbia EHRM Telecom Drawing Set 9 of 9.pdf PDF
S02 - Attachment 15 - Site Visit Instructions.pdf PDF
Show all 21

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FIRE PROTECTION GENERAL NOTES:

A. FIRE PROTECTION WORK SHALL INCLUDE, BUT NOT LIMITED TO, THE FOLLOWING: MODIFYING EXISTING WET-PIPE SPRINKLER SYSTEM IN RENOVATED AREAS WHERE THE ARCHITECTURAL FLOOR PLAN HAS CHANGED. MODIFYING THE EXISTING CLEAN AGENT FIRE SUPPRESSION

SYSTEM FOR THE MAIN SERVER ROOM.

B. ALL AREAS OF THE BUILDING INDICATED SHALL BE SPRINKLERED ACCORDING TO THE CURRENTLY ADOPTED EDITION OF NFPA STANDARD 13 AND OTHER NFPA STANDARDS AS REQUIRED. ENTIRE SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH VA STANDARDS.

C. FIRE SPRINKLER DESIGN SHALL BE MADE USING THE EFFECTIVE EXISTING PIPE SCHEDULE IN EACH BUILDING.

D. SPRINKLER CONTRACTOR SHALL OBTAIN STATIC AND RESIDUAL WATER PRESSURE AND FLOW PRIOR TO SYSTEM DESIGN AND SHALL SUBMIT

RECENT HYDRANT FLOW TEST DATA WITH SHOP DRAWING SUBMITTALS.

E. DRAWINGS ARE SCHEMATIC IN NATURE, INTENDED TO CONVEY THE SCOPE OF WORK AND GENERAL ARRANGEMENT OF THE SYSTEM.

SPRINKLER SYSTEM INSTALLING CONTRACTOR SHALL COORDINATE SYSTEM ARRANGEMENT WITH ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL COMPONENTS. SPRINKLER PIPING SHALL NOT BE INSTALLED BELOW MECHANICAL EQUIPMENT OR WITHIN CLEARANCE SPACES FOR MECHANICAL EQUIPMENT. PROVIDE SPRINKLER PROTECTION BELOW ALL DUCTS GREATER THAN 48 INCHES IN WIDTH. INSTALLING CONTRACTOR SHALL BE RESPONSIBLE FOR ANY MODIFICATIONS TO THE SYSTEM REQUIRED TO AVOID CONFLICTS.

F. AREAS IDENTIFIED INDICATE THE RECOMMENDED MINIMUM OCCUPANCY CLASSIFICATION, SPRINKLER TEMPERATURE CHARACTERISTIC OR SPRINKLER TYPES TO BE INSTALLED. SPRINKLER SYSTEM SHALL BE DESIGNED TO MEET OR EXCEED THESE RECOMMENDATIONS AND SHALL

BE SUBJECT TO APPROVAL BY THE VA.

G. A PRE-DESIGN MEETING SHALL BE COORDINATED WITH THE ARCHITECT PRIOR TO SUBMITTAL OF PIPING LAYOUT DRAWINGS. ARCHITECT

SHALL ISSUE COMMENTS CONCERNING SUBMITTAL PACKAGE PRIOR TO COMMENCEMENT OF WORK.

H. REFER TO ARCHITECTURAL PLANS FOR SPECIFIC CEILING TYPES AND HEIGHTS, AND AREAS OF EXPOSED STRUCTURE.

I. COORDINATE PIPING AND SPRINKLERS IN EXPOSED AREAS TO MINIMIZE APPEARANCE. INSTALL SPRINKLERS A MINIMUM OF SIX INCHES FROM

DIFFUSERS, GRILLES AND LIGHT FIXTURES. INSTALL SPRINKLERS IN LAY-IN CEILINGS WITHIN THREE INCHES OF THE CENTER OF CEILING TILE.

J. COORDINATE INSTALLATION OF SPRINKLERS AND PIPING SYSTEMS TO AVOID FREEZING CONDITIONS. NOTIFY ARCHITECT OF AREAS FOR

WHERE SYSTEM MAY BE EXPOSED TO FREEZING. INSTALL DRY SIDEWALL SPRINKLERS IN ROOMS INDICATED WHERE ROOMS MAY BE UNCONDITIONED OR EXPOSED TO FREEZING CONDITIONS. PROVIDE AUXILIARY DRAINS WHERE REQUIRED.

K. EXPOSED SPRINKLER PIPING, EXCEPT IN MECHANICAL AND STORAGE ROOMS, SHALL BE CLEANED, PRIMED AND PREPARED FOR PAINTING.

L. WHERE SPRINKLER PIPING SYSTEM PENETRATES FIRE RESISTIVE RATED ASSEMBLIES, SEAL OPENINGS WITH APPROVED CONSTRUCTION

METHODS AND MATERIALS.

M. AVOID ROUTING SPRINKLER PIPING ABOVE ELECTRICAL, DATA, IT AND COMMUNICATION PANELS.

N. ALL CLEAN AGENT SYSTEM INSTALLATIONS SHALL MEET VA STANDARDS AND NFPA 75.

O. IN AREAS WHERE FIRE PROTECTION WORK PENETRATES INTERIOR OR EXTERIOR WALLS, CEILING PANELS, GRID SYSTEMS, GYPSUM CEILINGS

AND/OR BULKHEADS, CONTRACTOR SHALL BE REQUIRED TO PATCH AND REPAIR PENETRATIONS AS A RESULT OF THE WORK.

SYMBOL

FIRE PROTECTION SYMBOLS

DESCRIPTION ADDITIONAL REMARKS

FLOW SWITCH COORDINATE INTERFACE WITH FIRE ALARM SYSTEM CONTRACTOR

FIRE DEPARTMENT CONNECTION MOUNT BETWEEN 18" AND 48" ABOVE FINISHED GRADE

REFER TO SPECIFICATIONS FOR TYPES AND FINISHES.

PENDANT REFERS TO FULL, SEMI-RECESSED AND RECESSED TYPES. LOCATIONS

FOR EACH ARE INDICATED IN THE SPECIFICATIONS OR ON THE PLANS.

SIDEWALL SPRINKLER -

EXISTING SIDEWALL SPRINKLER

SPRINKLER

EXISTING SPRINKLER

EXISTING SPRINKLER TO BE REMOVED

FIRE PIPEF

O.S. & Y. VALVE

SHUT-OFF VALVE WITH TAMPER SWITCHTS

F

ABBREVIATION

FIRE PROTECTION ABBREVIATIONS

DESCRIPTION

BACK FLOW PREVENTERBFP

FIRE PROTECTIONF

FIRE DEPARTMENT CONNECTIONFDC

ABBREVIATION DESCRIPTION

FLOW SWITCHFS

POST INDICATOR VALVEPIV

SPRINKLERSPR

NOT ALL ABBREVIATIONS APPLY TO THIS SET OF DOCUMENTS

NOT ALL SYMBOLS APPLY TO THIS SET OF DOCUMENTS

REFER TO SPECIFICATIONS FOR TYPES AND FINISHES.

PENDANT REFERS TO FULL, SEMI-RECESSED AND RECESSED TYPES. LOCATIONS

FOR EACH ARE INDICATED IN THE SPECIFICATIONS OR ON THE PLANS.

CLEAN AGENT HEAD

EXISTING CLEAN AGENT HEAD

EXISTING CLEAN AGENT HEAD TO BE REMOVED

DEMO (WHEN APPLIED TO EXISTING/DEMO ITEMS)D

Section A-A

A

A

System No. W-L-1251 F Ratings - 1 and 2 hr (See Item 1)

T Rating - 0 Hr

1. Wall Assembly - The 1 or 2 hr fire-rated gypsum board/stud shaft wall assembly shall be constructed of the materials and in the manner specified in the individual U400 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall incorporate the following construction features:

A. Steel Studs - "C-H" or "C-T" shaped studs, min 2-1/2 in. (64 mm) wide by 1-1/2 in. (38 mm) deep, fabricated from min No. 25 gauge (0.6 mm thick) galv steel, spaced max 24 in. (610 mm) OC.

B. Gypsum Board* - 1 in. (25 mm) thick, 24 in. (610 mm) wide gypsum liner panels installed vertically. Max diam of circular cutout in gypsum liner panel is 10 in. (254 mm).

C. Gypsum Board* - 1/2 in. or 5/8 in. (13 or 16 mm) thick, 48 in. (1.2 m) wide gypsum boards. The gypsum board type, thickness, number of layers, fastener type and sheet orientation shall be as specified in the individual Wall and Partition Design. Max diam of circular cutout in gypsum board is 10 in. (254 mm).

The hourly F Rating of the firestop system is equal to the hourly fire rating of the wall assembly in which it is installed.

2. Metallic Sleeve - Cylindrical sleeve fabricated from min No. 30 gauge (0.3 mm thick) galv sheet steel and having a min 2 in. (51 mm) lap along the longitudinal seam. Length of the sleeve to be equal to the thickness of the wall. Sleeve installed by coiling the sheet steel to a diam smaller than the through opening, inserting the coil through the opening and releasing the coil to let it uncoil against the circular cutouts in the gypsum board layers. The ends of the steel sleeve shall be flush with each surface of the wall.

3. Through Penetrant - - One metallic pipe, tube or conduit installed concentrically or eccentrically within the firestop system. The annular space between the pipe, tube or conduit and the periphery of the sleeved opening to be min 0 in. (0 mm, point contact) to max 2 in. (51 mm). Pipe, tube or conduit to be rigidly supported on both sides of wall assembly. One of the following types and sizes of pipe, tube or conduit may be used:

A. Steel Pipe - Nom 8 in. (203 mm) diam (or smaller) Schedule 5 (or heavier) steel pipe.

B. Iron Pipe - Nom 8 in. (203 mm) diam (or smaller) cast or ductile iron pipe.

C. Conduit - Nom 4 in. (102 mm) diam (or smaller) rigid steel conduit, steel electrical metallic tubing (EMT) or flexible steel conduit.

D. Copper Pipe or Tube - Nom 4 in. (102 mm) diam (or smaller) Regular (or heavier) copper pipe or Type L (or heavier) copper tube.

4. Firestop System - The firestop system consists of the following items:

A. Packing Material - Min 4 pcf (64 kg/m3) mineral wool batt insulation firmly packed into sleeved opening as a permanent form.

Packing material to extend throughout thickness of wall except for a 1 in. (25 mm) deep recess on the finished side of wall to accommodate the fill material.

B. Fill Void or Cavity Materials* - Sealant or Putty - Min 1 in. (25 mm) thickness of fill material applied with in sleeve, flush with finished surface of wall. At the point contact location, a min 3/8 in. (10 mm) diam bead of fill material shall be applied at the penetrant/sleeve interface.

SPECIFIED TECHNOLOGIES INC - SpecSeal Series SSS Sealant, SpecSeal LCI Sealant, or SpecSeal Putty

* Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as

Canada), respectively.

A

A Section A-A

1. Floor or Wall Assembly - Min 6 in. (152 mm) thick reinforced lightweight or normal weight (100-150 pcf or 1600-2400 kg/m3) concrete. Wall may also be constructed of any UL Classified Concrete Blocks*. Max diam of opening is 14 in. (356 mm).

See Concrete Block (CAZT) category in the Fire Resistance Directory for names of manufacturers.

2. Through Penetrants - One metallic pipe, conduit or tubing to be installed within the firestop system. The annular space shall range from min

0 in. (point contact) to max 1-1/8 in. (0 to 29 mm). Pipe, conduit or tubing to be rigidly supported on both sides of floor or wall assembly. The following types and sizes of metallic pipes, conduits or tubing may be used:

A. Steel Pipe - Nom 12 in. (305 mm) diam (or smaller) Schedule 5 (or heavier) steel pipe.

B. Iron Pipe - Nom 12 in. (305 mm) diam (or smaller) cast or ductile iron pipe.

C. Conduit - Nom 4 in. (102 mm) diam (or smaller) electrical metallic tubing or nom 6 in. (152 mm) diam (or smaller) rigid galv steel conduit.

D. Copper Tubing - Nom 4 in. (102 mm) diam (or smaller) Type L (or heavier) copper tubing.

E. Copper Pipe - Nom 4 in. (102 mm) diam (or smaller) Regular (or heavier) copper pipe.

3. Firestop System - The firestop system shall consist of the following:

A. Packing Material - (Optional, Not Shown) - Mineral wool batt insulation, polyethylene backer rod or glass fiber batt insulation friction fitted into annular space. Packing material to be recessed from top surface of floor or both surfaces of wall as required to accommodate the required thickness of fill material.

B. Fill, Void or Cavity Material* - Caulk - Min 1 in. (25 mm) thickness of fill material applied within the annulus, flush with top surface of floor or with both surfaces of wall. At point contact location, apply min 1/4 in. (6 mm) diam bead of sealant at the pipe/concrete interface on the op surface of the floor or both surfaces of wall.

SPECIFIED TECHNOLOGIES INC - Pensil 300 Sealant or SpecSeal Series SIL300 Sealant for floors or walls and Pensil 300S/L Sealant or SpecSeal Series SIL300SL Sealant for floors only.

* Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as

Canada), respectively.

Specified Technologies Inc. 210 Evans Way Somerville, NJ 08876

Reproduced courtesy of Underwriters Laboratories, Inc.

Created or Revised : December 14, 2010

(800)992-1180 * (908-526-800 * FAX (908)231-8415 * E-Mail:techserv@stifirestop.com * Website:www.stifirestop.com W-L-1251

Specified Technologies Inc. 210 Evans Way Somerville, NJ 08876

Reproduced courtesy of Underwriters Laboratories, Inc.

(800)992-1180 * (908-526-800 * FAX (908)231-8415 * E-Mail:techserv@stifirestop.com * Website:www.stifirestop.com

C-BJ-1058

Created or Revised : January 2, 2009

System No. C-BJ-1058 F Ratings - 2 Hr T Rating - 0 Hr

L Rating At Ambient - Less Than 1 CFM/sq ft L Rating At 400 F - Less Than 1 CFM/sq ft

W Rating - Class 1

4A

3B1 3B

4B

3 2

1A

4A

1B

4B

4B

1C

Location

Issue Date

Specialized Engineering Solutions

1300 Baxter Street, Suite 355

FULLY SPRINKLERED

COLUMBIA VA HEALTH CARE SYSTEM, COLUMBIA, SC

544-20-107PROJECT # 544-20-107

EHRM INFRASTRUCTURE UPGRADES

www.atriaxgroup.com

Atriax, pllc

102 3rd Avenue, NE

PO Box 1629, Hickory, NC 28603

Phone: 828.315.9962

Fax: 828.315.9964

NC Engineering License No.: P-0214

NC Architectural License No.: 51254

Project Number

Building Number

Drawing Number

Project Title

Checked Drawn

Drawing Title

Approved:

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

Project Director

Revisions: Date:

FOR OFFICIAL USE ONLY (FOUO)

FOR OFFICIAL USE ONLY (FOUO)

Wiley|Wilson 127 Nationwide Drive Lynchburg, VA 24502 Phone: 434.947.1901 www.wileywilson.com

VA FORM 08 - 6231

A

F ile

P a th

/1

/2

:3

:0

P

M

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

20375.007 07/14/2022

F000

FIRE PROTECTION SYMBOLS AND

ABBREVIATIONS VARIOUS

07/14/2022

100% CONSTRUCTION

DOCUMENTS

FIRE ALARM SYMBOLS

PLAN SYMBOL NAME

STROBE - WALL

FIRE ALARM SYMBOL LEGEND

PLAN SYMBOL NAME DESCRIPTION

DETECTOR - SYSTEM SMOKE -

CEILING

SYSTEM. REFER TO FIRE PROTECTION PLANS FOR LOCATION.

HORN - WALL AUDIO/VISUAL DEVICE, WALL MOUNTED, MATCH EXISTING SYSTEM. REFER TO FIRE PROTECTION PLANS FOR

LOCATION.

Revisions: Date:

LOGISTICS MAIL RM

AND PRINTING

TENANT SPACE

MAIL RM AND

PRINTING

LOGISTICS MAIL RM

AND PRINTING

109A

TENANT SPACE

RCC108R

TENANT SPACE

COMM CLO

RCC110R

COMMON CORR

RCC102R

TENANT SPACE

MAIL RM AND

PRINTING

VERTICAL SPACE

STAIR

RCC111R

TENANT SPACE

MAIL RM AND

PRINTING

TENANT SPACE

MAIL RM AND

PRINTING

TENANT SPACE

MAIL RM AND

PRINTING

COMMON CORR

RCC105R

TENANT SPACE USC

RCC107R

EDUCATION STOR

LOGISTICS

RCC106R

TENANT SPACE UCS

FITNESS CENTER

TENANT SPACE UCS

FITNESS CENTER

TENANT SPACE UCS

FITNESS CENTER

TENANT SPACE UCS

FITNESS CENTER

TENANT SPACE

MECH SPACE

104C

TENANT SPACE TLT

RCC104R

TENANT SPACE UCS

FITNESS CENTER

COMMON MECH RM

VERTICAL SPACE

CHASE

RCC102C

VERTICAL SPACE

CHASE

RCC101C

COMMON CORR

RCC101R

VERTICAL SPACE

ELEV

RCC109R

VERTICAL SPACE

ELEV

RCC104C

TENANT SPACE UCS

FITNESS CENTER

VERTICAL SPACE

CHASE

RCC103C

VERTICAL SPACE

STAIR

RCC112R

Location

Issue Date

Specialized Engineering Solutions

1300 Baxter Street, Suite 355

FULLY SPRINKLERED

COLUMBIA VA HEALTH CARE SYSTEM, COLUMBIA, SC

544-20-107PROJECT # 544-20-107

EHRM INFRASTRUCTURE UPGRADES

www.atriaxgroup.com

Atriax, pllc

102 3rd Avenue, NE

PO Box 1629, Hickory, NC 28603

Phone: 828.315.9962

Fax: 828.315.9964

NC Engineering License No.: P-0214

NC Architectural License No.: 51254

Project Number

Building Number

Drawing Number

Project Title

Checked Drawn

Drawing Title

Approved:

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

Project Director

Revisions: Date:

FOR OFFICIAL USE ONLY (FOUO)

FOR OFFICIAL USE ONLY (FOUO)

Wiley|Wilson 127 Nationwide Drive Lynchburg, VA 24502 Phone: 434.947.1901 www.wileywilson.com

VA FORM 08 - 6231

A

F ile

P a th

/1

/2

:3

:0

P

M

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

20375.007 07/14/2022

FD-005.1

B5 PARTIAL PLAN - LEVEL 1 - FIRE

PROTECTION DEMO 5

AGT PCM07/14/2022

100% CONSTRUCTION

DOCUMENTS

PLAN

NORTH

SCALE: 1/8" = 1'-0"

LEVEL 1 FLOOR PLAN - FIRE PROTECTION DEMOLITION

SHEET NOTES:

1. DEMOLISH FIRE PROTECTION PIPING BACK TO BOUNDARY OF NEW TR 109B.

GENERAL NOTES:

A. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.

B. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER PLANS, NEW

MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.

C. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL

PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED

D. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO

PERFORM THIS WORK.

TENANT SPACE

STOR

OPEN TO BELOW

EDUCATION

BALCONY

309MED MEDIA

PROJECTOR RM

VERT SPACE STAIR

RCC302R

MED MEDIA

PROJECTOR RM

300A

COMMON CORR

RCC301R

TENANT SPACE I G

TENANT SPACE I G

TENANT SPACE I G

TENANT SPACE I G

301A

TENANT SPACE I G

TENANT SPACE I G

TENANT SPACE I G

TENANT SPACE I G

VERTICAL SPACE

CHASE

RCC302C

VERTICAL SPACE

CHASE

RCC301C

OPEN TO BELOW

EDUCATION STOR

EDUCATION STOR

EDUCATION STOR

EDUCATION STOR

EDUCATION STOR

EDUCATION STOR

EDUCATION STOR

312B

EDUCATION STOR

312A

EDUCATION STOR

310A

VERT SPACE STAIR

RCC303R

Location

Issue Date

Specialized Engineering Solutions

1300 Baxter Street, Suite 355

FULLY SPRINKLERED

COLUMBIA VA HEALTH CARE SYSTEM, COLUMBIA, SC

544-20-107PROJECT # 544-20-107

EHRM INFRASTRUCTURE UPGRADES

www.atriaxgroup.com

Atriax, pllc

102 3rd Avenue, NE

PO Box 1629, Hickory, NC 28603

Phone: 828.315.9962

Fax: 828.315.9964

NC Engineering License No.: P-0214

NC Architectural License No.: 51254

Project Number

Building Number

Drawing Number

Project Title

Checked Drawn

Drawing Title

Approved:

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

Project Director

Revisions: Date:

FOR OFFICIAL USE ONLY (FOUO)

FOR OFFICIAL USE ONLY (FOUO)

Wiley|Wilson 127 Nationwide Drive Lynchburg, VA 24502 Phone: 434.947.1901 www.wileywilson.com

VA FORM 08 - 6231

A

F ile

P a th

/1

/2

:3

:0

P

M

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

07/14/2022

20375.007 FD-005.3

B5 PARTIAL PLAN - LEVEL 3 - FIRE

PROTECTION DEMO 5

AGT PCM07/14/2022

100% CONSTRUCTION

DOCUMENTS

PLAN

NORTH

SCALE: 1/8" = 1'-0"

LEVEL 3 FLOOR PLAN - FIRE PROTECTION DEMOLITION

A. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.

B. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN HATCHED AND/OR DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER

PLANS, NEW MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.

C. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL

PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.

D. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO

PERFORM THIS WORK.

GENERAL NOTES:

SHEET NOTES:

1. REMOVE EXISTING SPRINKLER HEAD FOR CEILING REMOVAL. REFER TO NEW WORK PLANS FOR

INSTALLATION OF NEW UPRIGHT HEADS. REPLACEMENT OF THE EXISTING PENDENT SPRINKLER WITH NEW UPRIGHT SPRINKLER SHALL OCCUR AT THE SAME TIME TO AVOID A SPRINKLER OUTAGE IN THE ROOM.

TR

109B

LOGISTICS MAIL RM

AND PRINTING

109A

(E)F

(E)F

F

LOGISTICS MAIL RM

AND PRINTING

TENANT SPACE

MAIL RM AND

PRINTING

TENANT SPACE

RCC108R

TENANT SPACE

COMM CLO

RCC110R

COMMON CORR

RCC102R

TENANT SPACE

MAIL RM AND

PRINTING

VERTICAL SPACE

STAIR

RCC111R

TENANT SPACE

MAIL RM AND

PRINTING

TENANT SPACE

MAIL RM AND

PRINTING

TENANT SPACE

MAIL RM AND

PRINTING

COMMON CORR

RCC105R

TENANT SPACE USC

RCC107R

EDUCATION STOR

LOGISTICS

RCC106R

TENANT SPACE UCS

FITNESS CENTER

TENANT SPACE UCS

FITNESS CENTER

TENANT SPACE UCS

FITNESS CENTER

TENANT SPACE UCS

FITNESS CENTER

TENANT SPACE

MECH SPACE

104C

TENANT SPACE TLT

RCC104R

TENANT SPACE UCS

FITNESS CENTER

COMMON MECH RM

VERTICAL SPACE

CHASE

RCC102C

VERTICAL SPACE

CHASE

RCC101C

COMMON CORR

RCC101R

VERTICAL SPACE

ELEV

RCC109R

VERTICAL SPACE

ELEV

RCC104C

TENANT SPACE UCS

FITNESS CENTER

VERTICAL SPACE

CHASE

RCC103C

VERTICAL SPACE

STAIR

RCC112R

Location

Issue Date

Specialized Engineering Solutions

1300 Baxter Street, Suite 355

FULLY SPRINKLERED

COLUMBIA VA HEALTH CARE SYSTEM, COLUMBIA, SC

544-20-107PROJECT # 544-20-107

EHRM INFRASTRUCTURE UPGRADES

www.atriaxgroup.com

Atriax, pllc

102 3rd Avenue, NE

PO Box 1629, Hickory, NC 28603

Phone: 828.315.9962

Fax: 828.315.9964

NC Engineering License No.: P-0214

NC Architectural License No.: 51254

Project Number

Building Number

Drawing Number

Project Title

Checked Drawn

Drawing Title

Approved:

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

Project Director

Revisions: Date:

FOR OFFICIAL USE ONLY (FOUO)

FOR OFFICIAL USE ONLY (FOUO)

Wiley|Wilson 127 Nationwide Drive Lynchburg, VA 24502 Phone: 434.947.1901 www.wileywilson.com

VA FORM 08 - 6231

A

F ile

P a th

/1

/2

:3

:0

P

M

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

20375.007 07/14/2022

F-005.1

B5 PARTIAL PLAN - LEVEL 1 - FIRE

PROTECTION 5

AGT PCM07/14/2022

100% CONSTRUCTION

DOCUMENTS

PLAN

NORTH

SCALE: 1/8" = 1'-0"

LEVEL 1 FLOOR PLAN - FIRE PROTECTION

SHEET NOTES:

1. REROUTE FIRE PROTECTION BRANCH OUTSIDE OF TR 109B. INSTALL NEW UPRIGHT SPRINKLER HEADS TO SERVE TR

109B. VERIFY COVERAGE REQUIREMENTS.

2. SPRINKLER PIPING SHALL NOT BE ROUTED ABOVE EQUIPMENT RACKS OR ELECTRICAL PANELS.

3. AREA OF EXISTING SPRINKLER COVERAGE. HAZARD CLASSIFICATION “LIGHT HAZARD”. RELOCATE AND/OR ADD ADDITIONAL HEADS AND PIPING TO MEET COVERAGE REQUIREMENTS PER NFPA 13 AND VA REQUIREMENTS.

COORDINATE HEAD LOCATIONS WITH EXISTING CONDITIONS AND ARCHITECT’S CEILING PLANS.

GENERAL NOTES:

A. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.

B. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER PLANS, NEW

MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.

C. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL

PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED

D. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO

(E)F

(E)F

(E)1" F UP

2 3

EDUCATION

KITCHEN

VERTICAL SPACE

STAIR

RCC202R

VERTICAL SPACE

ELEV

RCC203R

EDUCATION LOBBY

EDUCATION STAGE

RCC204R

VERTICAL SPACE

CHASE

RCC204R

EDUCATION STOR

VERTICAL SPACE

CHASE

RCC201C

EDUCATION MAIN

HALL

COMMON CORR

RCC201R

VERTICAL SPACE

STAIR

RCC206R

VERTICAL SPACE

STAIR

RCC205R

EDUCATION LOBBY

EDUCATION GREEN

RM

EDUCATION STOR

ENGINEERING

EDUCATION

WOMENS BATH

EDUCATION MENS

BATH

Location

Issue Date

Specialized Engineering Solutions

1300 Baxter Street, Suite 355

FULLY SPRINKLERED

COLUMBIA VA HEALTH CARE SYSTEM, COLUMBIA, SC

544-20-107PROJECT # 544-20-107

EHRM INFRASTRUCTURE UPGRADES

www.atriaxgroup.com

Atriax, pllc

102 3rd Avenue, NE

PO Box 1629, Hickory, NC 28603

Phone: 828.315.9962

Fax: 828.315.9964

NC Engineering License No.: P-0214

NC Architectural License No.: 51254

Project Number

Building Number

Drawing Number

Project Title

Checked Drawn

Drawing Title

Approved:

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

Project Director

Revisions: Date:

FOR OFFICIAL USE ONLY (FOUO)

FOR OFFICIAL USE ONLY (FOUO)

Wiley|Wilson 127 Nationwide Drive Lynchburg, VA 24502 Phone: 434.947.1901 www.wileywilson.com

VA FORM 08 - 6231

A

F ile

P a th

/1

/2

:3

:0

P

M

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

20375.007 07/14/2022

F-005.2

B5 PARTIAL PLAN - LEVEL 2 - FIRE

PROTECTION 5

AGT PCM07/14/2022

100% CONSTRUCTION

DOCUMENTS

PLAN

NORTH

SCALE: 1/8" = 1'-0"

LEVEL 2 FLOOR PLAN - FIRE PROTECTION

SHEET NOTES:

1. EXISTING SPRINKLERS SHALL REMAIN. PROVIDE MECHANICAL GUARD FOR EXISTING SPRINKLER HEAD. VERIFY

COVERAGE REQUIREMENTS.

2. SPRINKLER PIPING SHALL NOT BE ROUTED ABOVE EQUIPMENT RACKS OR ELECTRICAL PANELS.

3. AREA OF EXISTING SPRINKLER COVERAGE. HAZARD CLASSIFICATION “LIGHT HAZARD”. RELOCATE AND/OR ADD ADDITIONAL HEADS AND PIPING TO MEET COVERAGE REQUIREMENTS PER NFPA 13 AND VA REQUIREMENTS.

COORDINATE HEAD LOCATIONS WITH EXISTING CONDITIONS AND ARCHITECT’S CEILING PLANS.

GENERAL NOTES:

A. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.

B. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER PLANS, NEW

MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.

C. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL

PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED

D. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO

(E)F

2 3 OPEN TO BELOW

EDUCATION

BALCONY

309MED MEDIA

PROJECTOR RM

VERT SPACE STAIR

RCC302R

MED MEDIA

PROJECTOR RM

300A

COMMON CORR

RCC301R

TENANT SPACE I G

TENANT SPACE I G

TENANT SPACE I G

TENANT SPACE I G

301A

TENANT SPACE I G

TENANT SPACE I G

TENANT SPACE I G

TENANT SPACE I G

VERTICAL SPACE

CHASE

RCC302C

VERTICAL SPACE

CHASE

RCC301C

OPEN TO BELOW

EDUCATION STOR

EDUCATION STOR

EDUCATION STOR

EDUCATION STOR

EDUCATION STOR

EDUCATION STOR

EDUCATION STOR

312B

EDUCATION STOR

312A

EDUCATION STOR

310A

VERT SPACE STAIR

RCC303R

Location

Issue Date

Specialized Engineering Solutions

1300 Baxter Street, Suite 355

FULLY SPRINKLERED

COLUMBIA VA HEALTH CARE SYSTEM, COLUMBIA, SC

544-20-107PROJECT # 544-20-107

EHRM INFRASTRUCTURE UPGRADES

www.atriaxgroup.com

Atriax, pllc

102 3rd Avenue, NE

PO Box 1629, Hickory, NC 28603

Phone: 828.315.9962

Fax: 828.315.9964

NC Engineering License No.: P-0214

NC Architectural License No.: 51254

Project Number

Building Number

Drawing Number

Project Title

Checked Drawn

Drawing Title

Approved:

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

Project Director

Revisions: Date:

FOR OFFICIAL USE ONLY (FOUO)

FOR OFFICIAL USE ONLY (FOUO)

Wiley|Wilson 127 Nationwide Drive Lynchburg, VA 24502 Phone: 434.947.1901 www.wileywilson.com

VA FORM 08 - 6231

A

F ile

P a th

/1

/2

:3

:0

P

M

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

07/14/2022

20375.007 F-005.3

B5 PARTIAL PLAN - LEVEL 3 - FIRE

PROTECTION 5

AGT PCM07/14/2022

100% CONSTRUCTION

DOCUMENTS

PLAN

NORTH

SCALE: 1/8" = 1'-0"

LEVEL 3 FLOOR PLAN - FIRE PROTECTION

SHEET NOTES:

1. INSTALL NEW UPRIGHT SPRINKLER HEADS WITH MECHANICAL GUARDS TO SERVE TR 303. VERIFY COVERAGE REQUIREMENTS. REPLACEMENT OF THE EXISTING PENDENT SPRINKLER WITH NEW UPRIGHT SPRINKLER SHALL OCCUR

AT THE SAME TIME TO AVOID A SPRINKLER OUTAGE IN THE ROOM.

2. SPRINKLER PIPING SHALL NOT BE ROUTED ABOVE EQUIPMENT RACKS OR ELECTRICAL PANELS.

3. AREA OF EXISTING SPRINKLER COVERAGE. HAZARD CLASSIFICATION “LIGHT HAZARD”. RELOCATE AND/OR ADD ADDITIONAL HEADS AND PIPING TO MEET COVERAGE REQUIREMENTS PER NFPA 13 AND VA REQUIREMENTS.

COORDINATE HEAD LOCATIONS WITH EXISTING CONDITIONS AND ARCHITECT’S CEILING PLANS.

GENERAL NOTES:

A. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.

B. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER PLANS, NEW

MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.

C. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL

PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED

D. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO

F

ON-SITE LAUNDRY

LAUNDRY UNIT

ENGINEERING

MECH RM

W E

HUMAN RESRC SVC

CHIEF OFFICE

RCC104R

HUMAN RESRC SVC

PIV

COMMON TLT

COMMON TLT

COMMON TLT

104A

COMMON HALL - 1

ENGINEERING ELEC

CLOS

118A

HUMAN RESRC SVC

OFF

108A

HUMAN RESRC SVC

OFF

HUMAN RESRC SVC

OFF

HUMAN RESRC SVC

OFF

HUMAN RESRC SVC

HUMAN RESRC SVC

HUMAN RESRC SVC

TENANT SPACE HAC

COMMON TLT

COMMON TEL

COMMON ELEC

COMMON HALL - 3

COMMON VEST

HUMAN RESRC SVC

HUMAN RESRC SVC

PIV

RCC102R

HUMAN RESRC SVC

OFF

COMMON VEST

PRIMARY CARE OFF

HUMAN RESRC TLT

RCC106R

HUMAN RESRC SVC

STOR

RCC101R

PRIMARY CARE

EMPLOYEE HEALTH

ENGINEERING

MECHANICAL AREA

HUMAN RESRC SVC

BRK RM

RCC105R

RCC107R

RCC108R

VERTICAL SPACE

CHASE

RCC101C PRIMARY CARE

EMPLOYEE HEALTH

RCC103R

PRIMARY CARE OFF

COMMON HALL - 2

Location

Issue Date

Specialized Engineering Solutions

1300 Baxter Street, Suite 355

FULLY SPRINKLERED

COLUMBIA VA HEALTH CARE SYSTEM, COLUMBIA, SC

544-20-107PROJECT # 544-20-107

EHRM INFRASTRUCTURE UPGRADES

www.atriaxgroup.com

Atriax, pllc

102 3rd Avenue, NE

PO Box 1629, Hickory, NC 28603

Phone: 828.315.9962

Fax: 828.315.9964

NC Engineering License No.: P-0214

NC Architectural License No.: 51254

Project Number

Building Number

Drawing Number

Project Title

Checked Drawn

Drawing Title

Approved:

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

Project Director

Revisions: Date:

FOR OFFICIAL USE ONLY (FOUO)

FOR OFFICIAL USE ONLY (FOUO)

Wiley|Wilson 127 Nationwide Drive Lynchburg, VA 24502 Phone: 434.947.1901 www.wileywilson.com

VA FORM 08 - 6231

A

F ile

P a th

/1

/2

:3

:0

P

M

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

20375.007 07/14/2022

FD-006.1

B6 PARTIAL PLAN - LEVEL 1 - FIRE

PROTECTION DEMO 6

AGT PCM07/14/2022

100% CONSTRUCTION

DOCUMENTS

PLAN

NORTH

SCALE: 1/8" = 1'-0"

LEVEL 1 FLOOR PLAN - FIRE PROTECTION DEMOLITION

SHEET NOTES:

1. DEMOLISH FIRE PROTECTION PIPING BACK TO BOUNDARY OF NEW TR 110A.

A. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.

B. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN HATCHED AND/OR DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER

PLANS, NEW MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.

C. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL

PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.

D. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO

PERFORM THIS WORK.

GENERAL NOTES:

TR

110A

(E)F

F

(E)F

ENGINEERING

MECH RM

W

E

HUMAN RESRC SVC

CHIEF OFFICE

RCC104R

HUMAN RESRC SVC

PIV

COMMON TLT

COMMON TLT

COMMON TLT

104A

COMMON HALL - 1

ENGINEERING ELEC

CLOS

118A

HUMAN RESRC SVC

OFF

108A

HUMAN RESRC SVC

OFF

HUMAN RESRC SVC

OFF

HUMAN RESRC SVC

OFF

HUMAN RESRC SVC

HUMAN RESRC SVC

HUMAN RESRC SVC

TENANT SPACE HAC

COMMON TLT

COMMON TEL

COMMON ELEC

COMMON HALL - 3

COMMON VEST

HUMAN RESRC SVC

HUMAN RESRC SVC

PIV

RCC102R

HUMAN RESRC SVC

OFF

COMMON VEST

PRIMARY CARE OFF

ON-SITE LAUNDRY

LAUNDRY UNIT

HUMAN RESRC TLT

RCC106R

HUMAN RESRC SVC

STOR

RCC101R

PRIMARY CARE

EMPLOYEE HEALTH

ENGINEERING

MECHANICAL AREA

HUMAN RESRC SVC

BRK RM

RCC105R

RCC107R

RCC108R

VERTICAL SPACE

CHASE

RCC101C PRIMARY CARE

EMPLOYEE HEALTH

RCC103R

PRIMARY CARE OFF

COMMON HALL - 2

Location

Issue Date

Specialized Engineering Solutions

1300 Baxter Street, Suite 355

FULLY SPRINKLERED

COLUMBIA VA HEALTH CARE SYSTEM, COLUMBIA, SC

544-20-107PROJECT # 544-20-107

EHRM INFRASTRUCTURE UPGRADES

www.atriaxgroup.com

Atriax, pllc

102 3rd Avenue, NE

PO Box 1629, Hickory, NC 28603

Phone: 828.315.9962

Fax: 828.315.9964

NC Engineering License No.: P-0214

NC Architectural License No.: 51254

Project Number

Building Number

Drawing Number

Project Title

Checked Drawn

Drawing Title

Approved:

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

Project Director

Revisions: Date:

FOR OFFICIAL USE ONLY (FOUO)

FOR OFFICIAL USE ONLY (FOUO)

Wiley|Wilson 127 Nationwide Drive Lynchburg, VA 24502 Phone: 434.947.1901 www.wileywilson.com

VA FORM 08 - 6231

A

F ile

P a th

/1

/2

:3

:0

P

M

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

20375.007 07/14/2022

F-006.1

B6 PARTIAL PLAN - LEVEL 1 - FIRE

PROTECTION 6

AGT PCM07/14/2022

100% CONSTRUCTION

DOCUMENTS

PLAN

NORTH

SCALE: 1/8" = 1'-0"

LEVEL 1 FLOOR PLAN - FIRE PROTECTION

SHEET NOTES:

1. INSTALL NEW UPRIGHT SPRINKLER HEADS WITH MECHANICAL GUARDS TO SERVE TR 110A. VERIFY

COVERAGE REQUIREMENTS. REPLACEMENT OF THE EXISTING PENDENT SPRINKLER WITH NEW UPRIGHT

SPRINKLER SHALL OCCUR AT THE SAME TIME TO AVOID A SPRINKLER OUTAGE IN THE ROOM.

2. SPRINKLER PIPING SHALL NOT BE ROUTED ABOVE EQUIPMENT RACKS OR ELECTRICAL PANELS.

3. AREA OF EXISTING SPRINKLER COVERAGE. HAZARD CLASSIFICATION “LIGHT HAZARD”. RELOCATE AND/OR

ADD ADDITIONAL HEADS AND PIPING TO MEET COVERAGE REQUIREMENTS PER NFPA 13 AND VA

REQUIREMENTS. COORDINATE HEAD LOCATIONS WITH EXISTING CONDITIONS AND ARCHITECT’S CEILING

PLANS.

A. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.

B. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN HATCHED AND/OR DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER

PLANS, NEW MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.

C. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL

PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.

D. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO

PERFORM THIS WORK.

LOGISTICS

WAREHOUSE

RCC102R

LOGISTICS MALE

TLT

LOGISTICS COLD

RM

LOGISTICS VAULT

LOGISTICS FEMALE

TLT

LOGISTICS OFF

LOGISTICS

RCC101R

LOGISTICS

WAREHOUSE

RCC102R

LOGISTICS OFF

RCC104R

LOGISTICS OFF

RCC105R

LOGISTICS OFF

RCC106R

LOGISTICS OFF

RCC107R

Location

Issue Date

Specialized Engineering Solutions

1300 Baxter Street, Suite 355

FULLY SPRINKLERED

COLUMBIA VA HEALTH CARE SYSTEM, COLUMBIA, SC

544-20-107PROJECT # 544-20-107

EHRM INFRASTRUCTURE UPGRADES

www.atriaxgroup.com

Atriax, pllc

102 3rd Avenue, NE

PO Box 1629, Hickory, NC 28603

Phone: 828.315.9962

Fax: 828.315.9964

NC Engineering License No.: P-0214

NC Architectural License No.: 51254

Project Number

Building Number

Drawing Number

Project Title

Checked Drawn

Drawing Title

Approved:

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

Project Director

Revisions: Date:

FOR OFFICIAL USE ONLY (FOUO)

FOR OFFICIAL USE ONLY (FOUO)

Wiley|Wilson 127 Nationwide Drive Lynchburg, VA 24502 Phone: 434.947.1901 www.wileywilson.com

VA FORM 08 - 6231

A

F ile

P a th

/1

/2

:3

:0

P

M

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

20375.007 07/14/2022

FD-007.1A

B7 PARTIAL PLAN - LEVEL 1 - AREA

A - FIRE PROTECTION DEMO 7

AGT PCM07/14/2022

100% CONSTRUCTION

DOCUMENTS

PLAN

NORTH

SCALE: 1/8" = 1'-0"

LEVEL 1 FLOOR PLAN - FIRE PROTECTION DEMOLITION

SHEET NOTES:

1. AREA OF EXISTING SPRINKLER COVERAGE. HAZARD CLASSIFICATION “LIGHT HAZARD”. RELOCATE AND/OR

ADD ADDITIONAL HEADS AND PIPING TO MEET COVERAGE REQUIREMENTS PER NFPA 13 AND VA

REQUIREMENTS. COORDINATE HEAD LOCATIONS WITH EXISTING CONDITIONS AND ARCHITECT’S CEILING

PLANS.

A. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.

B. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN HATCHED AND/OR DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER

PLANS, NEW MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.

C. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL

PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.

D. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO

PERFORM THIS WORK.

(E)F

TR

LOGISTICS

WAREHOUSE

RCC102R

LOGISTICS MALE

TLT

LOGISTICS COLD

RM

LOGISTICS VAULT

LOGISTICS FEMALE

TLT

LOGISTICS OFF

LOGISTICS

RCC101R

LOGISTICS

WAREHOUSE

RCC102R

LOGISTICS OFF

RCC104R

LOGISTICS OFF

RCC105R

LOGISTICS OFF

RCC106R

LOGISTICS OFF

RCC107R

Location

Issue Date

Specialized Engineering Solutions

1300 Baxter Street, Suite 355

FULLY SPRINKLERED

COLUMBIA VA HEALTH CARE SYSTEM, COLUMBIA, SC

544-20-107PROJECT # 544-20-107

EHRM INFRASTRUCTURE UPGRADES

www.atriaxgroup.com

Atriax, pllc

102 3rd Avenue, NE

PO Box 1629, Hickory, NC 28603

Phone: 828.315.9962

Fax: 828.315.9964

NC Engineering License No.: P-0214

NC Architectural License No.: 51254

Project Number

Building Number

Drawing Number

Project Title

Checked Drawn

Drawing Title

Approved:

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

Project Director

Revisions: Date:

FOR OFFICIAL USE ONLY (FOUO)

FOR OFFICIAL USE ONLY (FOUO)

Wiley|Wilson 127 Nationwide Drive Lynchburg, VA 24502 Phone: 434.947.1901 www.wileywilson.com

VA FORM 08 - 6231

A

F ile

P a th

/1

/2

:3

:0

P

M

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

20375.007 07/14/2022

F-007.1A

B7 PARTIAL PLAN - LEVEL 1 - AREA

A - FIRE PROTECTION 7

AGT PCM07/14/2022

100% CONSTRUCTION

DOCUMENTS

PLAN

NORTH

SCALE: 1/8" = 1'-0"

LEVEL 1 FLOOR PLAN - FIRE PROTECTION

SHEET NOTES:

1. INSTALL NEW UPRIGHT SPRINKLER HEADS WITH MECHANICAL GUARDS TO SERVE TR 111. VERIFY COVERAGE

REQUIREMENTS.

2. SPRINKLER PIPING SHALL NOT BE ROUTED ABOVE EQUIPMENT RACKS OR ELECTRICAL PANELS.

3. AREA OF EXISTING SPRINKLER COVERAGE. HAZARD CLASSIFICATION “LIGHT HAZARD”. RELOCATE AND/OR

ADD ADDITIONAL HEADS AND PIPING TO MEET COVERAGE REQUIREMENTS PER NFPA 13 AND VA

REQUIREMENTS. COORDINATE HEAD LOCATIONS WITH EXISTING CONDITIONS AND ARCHITECT’S CEILING

PLANS.

A. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.

B. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN HATCHED AND/OR DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER

PLANS, NEW MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.

C. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL

PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.

D. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO

PERFORM THIS WORK.

(E)F (E)F

RESEARCH LAB

TENANT SPACE LAB

VERTICAL SPACE

CHASE

RCC107C

TENANT SPACE

STOR

TENANT SPACE

STOR

TENANT SPACE TEL

TENANT SPACE

ELEC

TENANT SPACE LAB

TENANT SPACE LAB

TENANT SPACE

VERTICAL SPACE

ELEV

RCC105R

TENANT SPACE

STOR

TENANT SPACE

CORR

TENANT SPACE LAB

TENANT SPACE

VEST

TENANT SPACE LAB

TENANT SPACE OFF

TENANT SPACE LAB

VERTICAL SPACE

CHASE

RCC104C

VERTICAL SPACE

CHASE

RCC103C

TENANT SPACE

CORR

RCC101R

TENANT SPACE OFF

TENANT SPACE

COMMON - INST

VERTICAL SPACE

CHASE

RCC102C

TENANT SPACE

MENS TLT

TENANT SPACE JAN

TENANT SPACE

WOMENS TLT

TENANT SPACE

WALK-IN REFRIG

TENANT SPACE 0FF

TENANT SPACE

VEST

TENANT SPACE

QUARANTINE WARD

TENANT SPACE

DISH WASHING

TENANT SPACE

CORR

TENANT SPACE

QUARANTINE WARD

TENANT SPACE

QUARANTINE WARD

233 VERTICAL SPACE

CHASE

RCC105C

TENANT SPACE

ANIMAL WARD

TENANT SPACE

VERTICAL SPACE

CHASE

RCC101C

TENANT SPACE LAB

TENANT MECH

SPACE

TENANT SPACE HAZ

STOR

COMMON

RESEARCH

RESEARCH OFF

RESEARCH OFF

RESEARCH OFF

VERTICAL SPACE

STAIR

VERTICAL SPACE

STAIR

RESEARCH TLT

RESEARCH TLT

RESEARCH STOR

RESEARCH CORR

RESEARCH MOUSE

RM

RESEARCH MOUSE

RM

RESEARCH ANTE

RESEARCH CORR

RESEARCH CORR

RESEARCH OFF

117C RESEARCH OFF

RESEARCH CONF

RM

117B

RESEARCH OFF

117ARESEARCH OFF

RESEARCH STOR

RESEARCH

RESEARCH

RESEARCH

RESEARCH

COMMON

RESEARCH

WOMENS TLT

Location

Issue Date

Specialized Engineering Solutions

1300 Baxter Street, Suite 355

FULLY SPRINKLERED

COLUMBIA VA HEALTH CARE SYSTEM, COLUMBIA, SC

544-20-107PROJECT # 544-20-107

EHRM INFRASTRUCTURE UPGRADES

www.atriaxgroup.com

Atriax, pllc

102 3rd Avenue, NE

PO Box 1629, Hickory, NC 28603

Phone: 828.315.9962

Fax: 828.315.9964

NC Engineering License No.: P-0214

NC Architectural License No.: 51254

Project Number

Building Number

Drawing Number

Project Title

Checked Drawn

Drawing Title

Approved:

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

Project Director

Revisions: Date:

FOR OFFICIAL USE ONLY (FOUO)

FOR OFFICIAL USE ONLY (FOUO)

Wiley|Wilson 127 Nationwide Drive Lynchburg, VA 24502 Phone: 434.947.1901 www.wileywilson.com

VA FORM 08 - 6231

A

F ile

P a th

/1

/2

:3

:0

P

M

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

20375.007 07/14/2022

FD-009.1

B9 PARTIAL PLAN - LEVEL 1 - FIRE

PROTECTION DEMO 9

AGT PCM07/14/2022

100% CONSTRUCTION

DOCUMENTS

PLAN

NORTH

SCALE: 1/8" = 1'-0"

LEVEL 1 FLOOR PLAN - FIRE PROTECTION DEMOLITION

SHEET NOTES:

1. DEMOLISH SPRINKLER PIPING BACK TO BOUNDARY OF NEW TR 110.

A. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.

B. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN HATCHED AND/OR DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER

PLANS, NEW MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.

C. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL

PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.

D. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO

PERFORM THIS WORK.

RESEARCH ADMIN.

(E)1" F UP

RESEARCH OFF

RESEARCH OFF

208RESEARCH DIRS

OFF

RESEARCH OFF

RESEARCH OFF

RESEARCH COLD

RM

RESEARCH SUPP

RESEARCH CHAS

RCC201C

RESEARCH CORR

RESEARCH CHAS

RCC202C

RESEARCH JAN

RESEARCH IT CLO

RESEARCH

WOMENS TLT

RESEARCH MENS

TLT

RESEARCH BSL #2

RM

RESEARCH CORR

RESEARCH ELECT

RESEARCH CELL

CULTURE RM

RESEARCH CHASE

RCC203C

RESEARCH LAB

RESEARCH WRK RM

VERTICAL SPACE

STAIR

Location

Issue Date

Specialized Engineering Solutions

1300 Baxter Street, Suite 355

FULLY SPRINKLERED

COLUMBIA VA HEALTH CARE SYSTEM, COLUMBIA, SC

544-20-107PROJECT # 544-20-107

EHRM INFRASTRUCTURE UPGRADES

www.atriaxgroup.com

Atriax, pllc

102 3rd Avenue, NE

PO Box 1629, Hickory, NC 28603

Phone: 828.315.9962

Fax: 828.315.9964

NC Engineering License No.: P-0214

NC Architectural License No.: 51254

Project Number

Building Number

Drawing Number

Project Title

Checked Drawn

Drawing Title

Approved:

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

Project Director

Revisions: Date:

FOR OFFICIAL USE ONLY (FOUO)

FOR OFFICIAL USE ONLY (FOUO)

Wiley|Wilson 127 Nationwide Drive Lynchburg, VA 24502 Phone: 434.947.1901 www.wileywilson.com

VA FORM 08 - 6231

A

F ile

P a th

/1

/2

:3

:0

P

M

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

20375.007 07/14/2022

FD-009.2

B9 PARTIAL PLAN - LEVEL 2 - FIRE

PROTECTION DEMO 9

AGT PCM07/14/2022

100% CONSTRUCTION

DOCUMENTS

PLAN

NORTH

SCALE: 1/8" = 1'-0"

LEVEL 2 FLOOR PLAN - FIRE PROTECTION DEMOLITION

SHEET NOTES:

1. REMOVE EXISTING SPRINKLER HEADS FOR SOFFIT REMOVAL. REFER TO NEW WORK PLANS FOR

INSTALLATION OF NEW UPRIGHT HEADS. REPLACEMENT OF THE EXISTING PENDENT SPRINKLER WITH NEW UPRIGHT SPRINKLER SHALL OCCUR AT THE SAME TIME TO AVOID A SPRINKLER OUTAGE IN THE ROOM.

A. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.

B. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN HATCHED AND/OR DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER

PLANS, NEW MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.

C. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL

PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.

D. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO

PERFORM THIS WORK.

F

(E)F(E)F

2 3

TENANT SPACE LAB

VERTICAL SPACE

CHASE

RCC107C

TENANT SPACE

STOR

TENANT SPACE

STOR

TENANT SPACE TEL

TENANT SPACE

ELEC

TENANT SPACE LAB

TENANT SPACE LAB

TENANT SPACE

VERTICAL SPACE

ELEV

RCC105R

TENANT SPACE

STOR

TENANT SPACE

CORR

TENANT SPACE LAB

TENANT SPACE

VEST

TENANT SPACE LAB

TENANT SPACE OFF

TENANT SPACE LAB

VERTICAL SPACE

CHASE

RCC104C

VERTICAL SPACE

CHASE

RCC103C

TENANT SPACE

CORR

RCC101R

TENANT SPACE OFF

TENANT SPACE

COMMON - INST

VERTICAL SPACE

CHASE

RCC102C

TENANT SPACE

MENS TLT

TENANT SPACE JAN

TENANT SPACE

WOMENS TLT

TENANT SPACE

WALK-IN REFRIG

TENANT SPACE 0FF

TENANT SPACE

VEST

TENANT SPACE

QUARANTINE WARD

TENANT SPACE

DISH WASHING

TENANT SPACE

CORR

TENANT SPACE

QUARANTINE WARD

TENANT SPACE

QUARANTINE WARD

233 VERTICAL SPACE

CHASE

RCC105C

TENANT SPACE

ANIMAL WARD

TENANT SPACE

VERTICAL SPACE

CHASE

RCC101C

TENANT SPACE LAB

TENANT MECH

SPACE

TENANT SPACE HAZ

STOR

COMMON

RESEARCH

RESEARCH OFF

RESEARCH OFF

RESEARCH OFF

VERTICAL SPACE

STAIR

VERTICAL SPACE

STAIR

RESEARCH TLT

RESEARCH TLT

RESEARCH STOR

RESEARCH CORR

RESEARCH MOUSE

RM

RESEARCH MOUSE

RM

RESEARCH ANTE

RESEARCH CORR

RESEARCH CORR

RESEARCH OFF

117C RESEARCH OFF

RESEARCH CONF

RM

117B

RESEARCH OFF

117ARESEARCH OFF

RESEARCH STOR

RESEARCH

RESEARCH

RESEARCH

RESEARCH

COMMON

RESEARCH

WOMENS TLT

Location

Issue Date

Specialized Engineering Solutions

1300 Baxter Street, Suite 355

FULLY SPRINKLERED

COLUMBIA VA HEALTH CARE SYSTEM, COLUMBIA, SC

544-20-107PROJECT # 544-20-107

EHRM INFRASTRUCTURE UPGRADES

www.atriaxgroup.com

Atriax, pllc

102 3rd Avenue, NE

PO Box 1629, Hickory, NC 28603

Phone: 828.315.9962

Fax: 828.315.9964

NC Engineering License No.: P-0214

NC Architectural License No.: 51254

Project Number

Building Number

Drawing Number

Project Title

Checked Drawn

Drawing Title

Approved:

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

Project Director

Revisions: Date:

FOR OFFICIAL USE ONLY (FOUO)

FOR OFFICIAL USE ONLY (FOUO)

Wiley|Wilson 127 Nationwide Drive Lynchburg, VA 24502 Phone: 434.947.1901 www.wileywilson.com

VA FORM 08 - 6231

A

F ile

P a th

/1

/2

:3

:0

P

M

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

20375.007 07/14/2022

F-009.1

B9 PARTIAL PLAN - LEVEL 1 - FIRE

PROTECTION 9

AGT PCM07/14/2022

100% CONSTRUCTION

DOCUMENTS

PLAN

NORTH

SCALE: 1/8" = 1'-0"

LEVEL 1 FLOOR PLAN - FIRE PROTECTION

SHEET NOTES:

1. INSTALL NEW UPRIGHT SPRINKLER HEADS WITH MECHANICAL GUARDS TO SERVE TR 110. VERIFY

COVERAGE REQUIREMENTS. REPLACEMENT OF THE EXISTING PENDENT SPRINKLER WITH NEW UPRIGHT

SPRINKLER SHALL OCCUR AT THE SAME TIME TO AVOID A SPRINKLER OUTAGE IN THE ROOM.

2. SPRINKLER PIPING SHALL NOT BE ROUTED ABOVE EQUIPMENT RACKS OR ELECTRICAL PANELS.

3. AREA OF EXISTING SPRINKLER COVERAGE. HAZARD CLASSIFICATION “LIGHT HAZARD”. RELOCATE AND/OR ADD ADDITIONAL HEADS AND PIPING TO MEET COVERAGE REQUIREMENTS PER NFPA 13 AND VA REQUIREMENTS. COORDINATE HEAD LOCATIONS WITH EXISTING CONDITIONS AND ARCHITECT’S CEILING

PLANS

A. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.

B. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN HATCHED AND/OR DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER

PLANS, NEW MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.

C. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL

PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.

D. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO

PERFORM THIS WORK.

2 3

(E)1" F UP

F

RESEARCH OFF

RESEARCH OFF

208RESEARCH DIRS

OFF

RESEARCH OFF

RESEARCH OFF

RESEARCH COLD

RM

RESEARCH SUPP

RESEARCH CHAS

RCC201C

RESEARCH CORR

RESEARCH CHAS

RCC202C

RESEARCH JAN

RESEARCH IT CLO

RESEARCH

WOMENS TLT

RESEARCH MENS

TLT

RESEARCH BSL #2

RM

RESEARCH CORR

RESEARCH ELECT

RESEARCH CELL

CULTURE RM

RESEARCH CHASE

RCC203C

RESEARCH LAB

RESEARCH WRK RM

VERTICAL SPACE

STAIR

Location

Issue Date

Specialized Engineering Solutions

1300 Baxter Street, Suite 355

FULLY SPRINKLERED

COLUMBIA VA HEALTH CARE SYSTEM, COLUMBIA, SC

544-20-107PROJECT # 544-20-107

EHRM INFRASTRUCTURE UPGRADES

www.atriaxgroup.com

Atriax, pllc

102 3rd Avenue, NE

PO Box 1629, Hickory, NC 28603

Phone: 828.315.9962

Fax: 828.315.9964

NC Engineering License No.: P-0214

NC Architectural License No.: 51254

Project Number

Building Number

Drawing Number

Project Title

Checked Drawn

Drawing Title

Approved:

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

Project Director

Revisions: Date:

FOR OFFICIAL USE ONLY (FOUO)

FOR OFFICIAL USE ONLY (FOUO)

Wiley|Wilson 127 Nationwide Drive Lynchburg, VA 24502 Phone: 434.947.1901 www.wileywilson.com

VA FORM 08 - 6231

A

F ile

P a th

/1

/2

:3

:0

P

M

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

20375.007 07/14/2022

F-009.2

B9 PARTIAL PLAN - LEVEL 2 - FIRE

PROTECTION 9

AGT PCM07/14/2022

100% CONSTRUCTION

DOCUMENTS

1/8" = 1'-0"

LEVEL 2 FLOOR PLAN - FIRE PROTECTION

SHEET NOTES:

1. INSTALL NEW UPRIGHT SPRINKLER HEADS WITH MECHANICAL GUARDS TO SERVE TR 210. VERIFY COVERAGE

REQUIREMENTS. REPLACEMENT OF THE EXISTING PENDENT SPRINKLER WITH NEW UPRIGHT SPRINKLER

SHALL OCCUR AT THE SAME TIME TO AVOID A SPRINKLER OUTAGE IN THE ROOM.

2. SPRINKLER PIPING SHALL NOT BE ROUTED ABOVE EQUIPMENT RACKS OR ELECTRICAL PANELS.

3. AREA OF EXISTING SPRINKLER COVERAGE. HAZARD CLASSIFICATION “LIGHT HAZARD”. RELOCATE AND/OR

ADD ADDITIONAL HEADS AND PIPING TO MEET COVERAGE REQUIREMENTS PER NFPA 13 AND VA

REQUIREMENTS. COORDINATE HEAD LOCATIONS WITH EXISTING CONDITIONS AND ARCHITECT’S CEILING

PLANS.

4. EXISTING SPRINKLER PIPE UP TO ATTIC.

A. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.

B. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN HATCHED AND/OR DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER

PLANS, NEW MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.

C. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL

PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.

D. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO

PERFORM THIS WORK.

E

FE

F E

FE F

E

FE

1 2

1 2

ENG. SHOP

125A(E)F

TR

125B

ENG. SHOPS

ENG. SHOPS

ENG. SHOPS

ENG. SHOPS

127A

ENG. SHOPS

ENG. TLT

ENG. BRK RM

ENG. SHOPS

ENG. SHOPS

ENGINEERING OFF

ENGINEERING OFF

ENG. ASSISTANT

CHIEF OFF

ENGINEERING OFF

ENGINEERING OFF

ENGINEERING STOR

VERTICAL SPACE

CHASE

RCC101C

ENG. SHOPS

121A

ENG. SHOPS

121B

ENG. TELE CLO

121-C

ENGINEERING

PANEL RM

ENG. WRK RM

111ENGINEERING OFF

ENG. SHOPS

119A

ENG. STOR

ENG. CONF RM

ENGINEERING

INTERIOR DESIGN

OFFICE

118A ENGINEERING TLT

ENG. HAC

ENGINEERING TLT

ENG. HAC

ENGINEERING OFF

ENGINEERING OFF

112A

ENGINEERING OFF

ENGINEERING OFF

ENGINEERING OFF

ENG. CHIEF OFF

ENGINEERING

CORR

114 ENGINEERING

ENTRYWAY

RCC103R

Location

Issue Date

Specialized Engineering Solutions

1300 Baxter Street, Suite 355

FULLY SPRINKLERED

COLUMBIA VA HEALTH CARE SYSTEM, COLUMBIA, SC

544-20-107PROJECT # 544-20-107

EHRM INFRASTRUCTURE UPGRADES

www.atriaxgroup.com

Atriax, pllc

102 3rd Avenue, NE

PO Box 1629, Hickory, NC 28603

Phone: 828.315.9962

Fax: 828.315.9964

NC Engineering License No.: P-0214

NC Architectural License No.: 51254

Project Number

Building Number

Drawing Number

Project Title

Checked Drawn

Drawing Title

Approved:

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

Project Director

Revisions: Date:

FOR OFFICIAL USE ONLY (FOUO)

FOR OFFICIAL USE ONLY (FOUO)

Wiley|Wilson 127 Nationwide Drive Lynchburg, VA 24502 Phone: 434.947.1901 www.wileywilson.com

VA FORM 08 - 6231

A

F ile

P a th

/1

/2

:3

:0

P

M

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

20375.007 07/14/2022

F-020.1

B20 PARTIAL PLAN - LEVEL 1 -

FIRE PROTECTION 20

AGT PCM07/14/2022

100% CONSTRUCTION

DOCUMENTS

PLAN

NORTH

SCALE: 1/8" = 1'-0"

LEVEL 1 FLOOR PLAN - FIRE PROTECTION

SHEET NOTES:

1. PROVIDE MECHANICAL GUARD FOR EXISTING SPRINKLER HEAD.

2. AREA OF EXISTING SPRINKLER COVERAGE. HAZARD CLASSIFICATION “LIGHT HAZARD”. RELOCATE AND/OR

ADD ADDITIONAL HEADS AND PIPING TO MEET COVERAGE REQUIREMENTS PER NFPA 13 AND VA

REQUIREMENTS. COORDINATE HEAD LOCATIONS WITH EXISTING CONDITIONS AND ARCHITECT’S CEILING

PLANS.

A. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.

B. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN HATCHED AND/OR DASHED, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER

PLANS, NEW MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.

C. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL

PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.

D. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO

PERFORM THIS WORK.

UP

DN

DN

UP

H

H

H

H

D

TR

ELECTRICAL

GENERATOR

TRAINING/BREAK

RM

CORRIDOR

ECC SUPERVISOR

CUSTODIAL

MENS LOCKER

MENS TOILET

104A

SUPERVISOR

OFFICE

WOMENS TOILET

103AWOMENS LOCKER

STORAGE

WORK/REFERENCE

AREA

101A

CONTROL RM

BOILER RM

CHEMICAL

FEED/TESTING

100A

Loc…

This is the start of the file's text. The full file is on GovTribe.