This document collection comprises the design and construction bid documents for the Fort Sill Gravesite Expansion and Cemetery FCA Improvements project located in Elgin, Oklahoma, issued by the National Cemetery Administration (NCA) under the U.S. Department of Veterans Affairs. The project number is 920CM3006, with an issue date of July 1, 2026. The design was prepared by JD Engineering, PC (Hamilton, MT) with Sean M. Fitzpatrick as the licensed architect, and Pland Consultant providing architectural/engineering services.
The project encompasses comprehensive cemetery expansion and improvement work including: construction of columbarium walls with precast concrete niche units (multiple configurations of 3-5 heights by 5-9 widths), installation of bronze service seals (18" diameter units for Army, Marine Corps, Navy, Air Force, Space Force, and Coast Guard), marble niche covers with stainless steel hardware, stone veneer repair and new work, committal shelters with observation walls, foundation systems, mechanical systems (split HVAC units including Mitsubishi equipment), plumbing infrastructure, electrical installation and demolition work across multiple buildings (Administration, Maintenance, and Public Information buildings), door and window schedules with replacement specifications, site work including drainage and grading, and various finish details. The bid documents include detailed architectural drawings (A-series), structural/foundation plans (S-series), mechanical schematics and schedules (M-series), electrical plans with demolition requirements and lighting details (E-series), and comprehensive general notes addressing installation standards, coordination requirements, and compliance with NEC, NFPA codes and VA specifications.
View the file
Other files
Show all 36
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SECTION THROUGH SEAL SHOWING
METHOD OF ATTACHMENT
MATERIAL:
BRONZE: FEDERAL SPECIFICATION QQ-C-535B, COMPOSITION 2.
WORKMANSHIP:
CASTINGS SHALL BE OF UNIFORM QUALITY AND CONDITION, FREE FROM INJURIOUS BLOWHOLES AND POROSITY, CRACKS AND OTHER DEFECTS AND NOT WARPED OR DISTORTED, WELL FINISHED, FREE FROM BURRS, SHARP EDGES, SCRATCHES AND DEFECTS THAT MAY AFFECT APPEARANCE OR
SERVICEABILITY. CASTINGS SHALL NOT BE REPAIRED, PLUGGED, WELDED, OR BURNED.
FINISH:
FINISH TO BE DETAILED, HAND CHASED FOR TRUE ALIGNMENT, FILED, BELT POLISHED SIDES
GROUND SMOOTH, RAISED SURFACES AND BORDERS, SUCH AS ALL RAISED PORTIONS OF SEAL,
EAGLE, SHIELD, LETTERING, ROPE BORDER ETC., TO BE POLISHED AND BUFFED TO A BRIGHT SATIN
FINISH, BACKGROUND TEXTURES TO BE REVERSE MEDIUM PEBBLE BACKGROUND, FINE PEBBLE
BACKGROUND, MOSS AS CAST, AS INDICATED.
COATING:
BRONZE: CHEMICALLY OXIDIZE TO A STATUARY MEDIUM COLOR AND FINISH WITH ONE COAT OF
CLEAR PROTECTIVE EXTERIOR METAL LACQUER.
FASTENERS:
BRONZE FASTENERS TO BE COMPATIBLE WITH MATERIAL OF CASTING.
SEALS REQUIRED:
ARMY - 3, 18" DIA.
MARINE CROPS - 3, 18" DIA.
NAVY - 3, 18" DIA.
AIR FORCE - 3, 18" DIA.
SPACE FORCE - 3, 18" DIA.
COAST GUARD - 3, 18" DIA.
SEALS ARE TO BE SUPPLIED AND INSTALLED BY CONTRACTOR
GENERAL NOTES
LOCATION OF
SOLID METAL
PORTION OF
SEAL
SOLID METAL PORTION ON BACK OF SEAL, DRILL AND TAP
FOR STUDS-3 LOCATIONS AS INDICATED ON ELEVATIONS.
ROPE BORDER
CONTINUOUS
LOCATION OF
SOLID METAL
PORTION OF
SEAL
PROFILE OF SEAL
LOCATION OF SOLID
METAL PORTION OF
SEAL
DRILL IN CONCRETE OR SOLID MASONRY AND FILL WITH EPOXY
IMMEDIATELY PRIOR TO SETTING SEAL
FACE OF
WALL
SAME AS
ABOVE
FRONT
FACE OF
SEAL
MEDIUM PEBBLE
FINISH, ALL
BACKGROUND
AREAS.
8" BRONZE THREADED STUDS SCREWED INTO SOLID METAL
PORTION ON BACK OF SEAL. POSITION INTO DRILLED HOLES IN
MASONRY FACE WHILE EPOXY IS WET. PROVIDE BRONZE BOLTS
FOR BRONZE SEAL.
1/4" MAXBRASS SEAL
MASONRY WALL
THREADED MOUNTING
STUD AS RECOMMENDED
BY MANUFACTURER
FIELD DRILLED HOLE TO
MATCH MOUNTING STUD,
4" DIA. HOLE SECURED
WITH EPOXY GROUT
NATURAL STONE
VENEER RESTORE AND
REUSE EXISTING PIECES
WEEP HOLES @ 24" O.C.
THRU WALL FLASHING
MASONRY WALL TIES @
1'-4" O.C. HORIZ. AND VERT.
EXISTING CONCRETE
SLAB
FINISHED FLOOR
MORTAR JOINT TYPE N
FOR AREAS WHERE THE
CONCRETE SLAB EXTENDS TO THE
FINISHED FLOOR LEVEL, THE SLAB
BENEATH THE STONE WILL NEED
TO BE SAWCUT AND LEVELED WITH
THE REST OF THE FOUNDATION TO
AVOID FUTURE CRACKING.
2'-4"
2'-0"
1'-0"
2"
1' -0
2"
6"
ARCHITECTURAL PRECAST WALL CAP;
MTL., FINISH & COLOR TO MATCH
EXISTING. PROVIDE 3/8" JOINT
BETWEEN CAP SECTIONS; SET ON 1/2"
FULL MORTAR BED; 3/8" GAP BETWEEN
UNITS, W/ BACKER ROD & SEALANT.
1/4" x 1/4" CONTINUOUS DRIP SLOT ON
BOTH SIDES. LOCATE DRIP SLOTS 1"
FROM CAP EDGES.
1/2" FULL MORTAR BED
NOTE: ALL DIMENSIONS IN THIS
DETAIL NEED TO BE FIELD VERIFIED
BACKER ROD AND SEALANT. BOTH
SIDES.
1/2" [12.7] x 6" [152] TYPE 304 S.S. PIN, 2
PINS PER CAP SECTION; SET W/NON-
METALLIC NON-SHRINK GROUT, TYP.
EXISTING STONE VENEER
FINISH GRADE
(CONC. PVMT.)
NEW 18" DIA. SERVICE
SEALS
EXISTING NATURAL
STONE VENEER TO BE
RESTORED AND REUSED
EXISTING CONCRETE
SLAB
FINISHED FLOOR
REMOVE EXISTING
MORTAR FROM AREAS OF
STONE REPAIR
FOR AREAS WHERE THE
CONCRETE SLAB EXTENDS TO THE
FINISHED FLOOR LEVEL, THE SLAB
BENEATH THE STONE WILL NEED
TO BE SAWCUT AND LEVELED WITH
THE REST OF THE FOUNDATION TO
AVOID FUTURE CRACKING.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
BID DOCUMENTS
N/A
National Cemetery Administration
Design and Construction Service
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
FORT SILL
GRAVESITE EXPANSION AND
CEMETERY FCA IMPROVEMENTS
Elgin, OK
920CM3006
N/A
07/01/2026Revisions: Date: JV
Approved: Project Manager/COR Department of Veteran Affairs, NCA POC: Homayoun Kazemipour Email: homayoun.kazemipour@va.gov
720.491.7559; Sean Fitzpatrick
56 LOUIS PRIMA DRIVE, SUITE B, COVINGTON, LA 70433 JB
JD Engineering, PC 371 Zimmerman Lane Hamilton, MT 59840 Phone: (406) 218 - 9980
No. 44593
PROFESSIONAL
REGISTERED
JORDAN D. VANDERMEE
RENGINEER
COMMITTAL SHELTERS &
OBSERVATION WALL DETAILS
SF DH
A-501
SCALE: N.T.S
SERVICE SEAL DETAILF8
SCALE: N.T.S
SEAL ATTACHMENT DETAILB6
SCALE: N.T.S
STONE VENEER REPAIR NEW WORKF4
SCALE: 1"=1'-0"
OBSERVATION WALL CAP REPLACEMENTD1
SCALE: N.T.S
STONE VENEER REPAIR DEMO WORKF1
CO
LO
RADO L ICENSED
ARCH I T ECT
SE
AN
M. FITZPATRICK
07/01/26
AutoCAD SHX Text
18" DIAMETER
AutoCAD SHX Text 12/30/2026
AutoCAD SHX Text 00404366
CONCRETE
BACKER ROD
SEALANT
AIR SPACE
PROVIDE SMOOTH
SURFACE ON
STONE FACE AT
AREA TO RECEIVE
SEALANT AND
BACKER ROD (TYP)
1/2"
M
IN1
CONCRETE
BACKER ROD
SEALANT
STONE
PROVIDE SMOOTH
SURFACE ON
STONE FACE AT
AREA TO RECEIVE
SEALANT AND
BACKER ROD (TYP)
STONE
VENEER
BACKER ROD
SEALANT
STONE
VENEER
M
IN1
1/2" 1/2"
B6
CONC TO CONC JOINT DETAIL
NTS
B8
STONE TO CAP JOINT DETAIL
NTS
CONCRETE
SECTION A'-A
N.T.S.
NICHE ID
ELEVATION
NTS
A'
A
NOTE:
CAST ALUMINUM LETTERS AND NUMBERING SHALL MATCH EXISTING . STAINLESS STEEL STUDS SHALL BE USED.
REFER TO CAP NUMBERING PLAN AND ELEVATIONS FOR COLUMNS AND ROW NUMBERING
COLUMBARIUM CAP
OR MARBLE SIDE
FILLER
1/2" (1.27CM) X 2" (1.27CM)
LONG STAINLESS STEEL
BOLT
EPOXIED INTO LIMESTONE
CAP OR MARBLE SIDE
FILLER CAST ALUMINUM PLAQUE,
LETTERING &
NUMBERING; ANCHORED
AS SHOWN
1/8"
1/2"3/8"∅
1/2" THICK x 2" ROUND CAST
ALUMINUM PLAQUE W/7/8"
TALL FONT TO MATCH
EXISTING ROW LABEL
LETTERING, AND COLUMN
NUMBERING, TYP.
IMPRINT TO BE
HORIZONTALLY BRUSHED
SATIN ALUMINUM.
INFILL COLOR TO BE VICTOR
STANLEY BRONZE W/ PEBBLE
FINISH.
1/8" PROJECTION STUD
MOUNTED.
/8
/8
1" 1/2" VARIES
/8
1/4"
VARIES. SEE CAP PLAN
CUT STONE CAP
BACKER ROD
SEALANT
CONTINUOUS DRIP
CHAMFERED
V-SHAPE GROOVE
ON ALL SIDESCONCRETE NICHE UNIT CONTINUOUS EPDM
FLASHING MEMBRANE
S.S. SHIMS OR
LEVELING GROUT
A'
A
8"
LIMESTONE IDENTIFICATION PANEL (TYP.)
WHERE SHOWN ON COLUMBARIUM
ELEVATIONS: FINISH & COLOR TO MATCH
CAP; PANEL TO BE CAST WITH 6" HEIGHT.
NUMBER (FONT TO MATCH EXISTING) AS
SHOWN ON ELEVATIONS; NUMBER TO BE
STAINED TO MATCH EXISTING.
NOTE: REFER TO CAP
NUMBERING PLAN AND
ELEVATIONS FOR WALL ID
PANEL NUMBERING
SECTION A-A'
3"
ETCH NUMBER
EXPANSION ANCHOR 1/4" X 2"
STAINLESS STEEL HILTI HIT ANCHOR
STONE ANCHOR 3/16" X 1-1/4" WIDE
STAINLESS STEEL "Z" ANCHOR WITH
STAINLESS STEEL EXPANSION
ANCHOR, LENGTH AS REQUIRED
STONE VENEER
CUT LIMESTONE
CAP (TYPICAL)
SEALANT COLOR
TO MATCH CAP1/4"1/2"
BACKER ROD
MASONRY WEEP VENT FLUSH WITH FACE
OF NICHE UNIT, SECURED EA. SIDE WITH
CAULK
3" WIDE CONTINUOUS STAINLESS STEEL
FLASHING PAN WITH EDGES TURNED UP
1/4" TO 3/8" -FULL WIDTH OF NICHE UNITS
CONTINUOUS EPDM MEMBRANE,
ACROSS LENGTH OF WALL
GROUT
1 5/8"3"
PRECAST COLUMBARIUM
NICHES (TYPICAL)
STAINLESS 304
STEEL ANCHORS
STONE VENEER
CONCRETE WALL
FOUNDATION
RECESSED LIMESTONE
COLUMBARIUM ID PANEL,
SEE D5/A-502
3/4" X 5 1/4"X LENGTH VARIES WHITE
MARBLE SIDE FILLER, TO MATCH NICHE
COVERS.
WHITE MARBLE NICHE COVER, SUPPLIED BY
GOVERNMENT AND INSTALLED BY
CONTRACTOR, SEE E1/ A-504
PRECAST CONCRETE NICHE UNIT
AIR SPACE
1/2" WIDE JOINT WITH
BACKER ROD AND SEALANT
ALIGN
1/2" WIDE JOINT WITH
BACKER ROD AND SEALANT
1/4" X 2" LONG STAINLESS STEEL ALL-
THREAD EPOXIED THRU MARBLE SIDE FILLER
PANEL AND INTO CONCRETE WALL. 2 - PER
PANEL TO BE LOCATED BEHIND THE CENTER
OF THE ROW LETTER MEDALLIONS.
HEMMED EDGE
VERTICAL CELL
VENT/WEEP@ 24" O.C.
PREFINISHED
S.S. FLASHING
CUT STONE
OPEN AIR CAVITY
HEMMED EDGE
O V
E R
L A
P
STAINLESS STEEL
FLASHING
REGLET SAW CUT
SEE CIVIL FOR GRADING
12" = 1'-0" B1
COLUMBARIUM LETTERING
6" = 1'-0" B7
CON TO STONE JOINT DETAIL
6" = 1'-0" D5
COLUMBARIUM WALL ID PANEL
6" = 1'-0" F1
CAP DRIP DETAIL
07/01/26
00404366C O
LO
RADO L ICENS
E
D
A
RC H I T EC
T
S
EA
N
M. F ITZPATR
IC
K
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
N/A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
7 8 9 10321 4 5 6
07/01/2026
National Cemetery Administration
Design and Construction Service
JD Engineering, PC 371 Zimmerman Lane
Hamilton, MT 59840
Phone: (406) 218 - 9980
Elgin, OK
N/A
U.S. Department of Veterans Affairs
BID DOCUMENTS FORT SILL
GRAVESITE EXPANSION AND
CEMETERY FCA IMPROVEMENTSJD Engineering, PC 371 Zimmerman Lane
Hamilton, MT 59840
Phone: (406) 218 - 9980
720.491.7559; Sean Fitzpatrick
56 LOUIS PRIMA DRIVE, SUITE B, COVINGTON, LA 70433
Location
920CM3006
Approved: Project Manager/COR Department of Veteran Affairs, NCA POC: Homayoun Kazemipour Email: homayoun.kazemipour@va.gov
A-502
COLUMBARIUM DETAILS
SF IN
12" = 1'-0" D1
STONE CAP JOINT DETAIL
3" = 1'-0" F7
END WALL ENLARGED DETAIL
3" = 1'-0"
F5
FLASHING DETAIL
Revisions: Date:
9' - 1 1/2"
11 7/8" 1' - 0"
8' - 2"
1' - 0 3/4" 1' - 0"
4' - 1 1/2"
1' - 0 3/8" 1' - 0"
8' - 1 1/2"
1' - 0 3/4" 1' - 0" 7' - 1 1/2"
1' - 1" 1' - 0"
5' - 1 1/2"
1' - 0 3/4" 1' - 0"
9' - 1 1/2"
1' - 0 3/4" 1' - 0"
8' - 1 1/2"
/4
/2
/2
/2
1 1/2" 10 1/2" 1 1/2"
4' - 1 1/2"
/4
/2
/2
/2
1 1/2" 10 1/2" 1 1/2"
5' - 1 1/2"
/4
/2
/2
1 1/2" 10 1/2" 1 1/2"
/2
9' - 1 1/2"
/2
1 1/2" 10 1/2" 1 1/2"
/2
/2
8' - 1 1/2"
/2
/2
/2
1 1/2" 10 1/2" 1 1/2"
7' - 1 1/2"
/2
/2
/2
1 1/2" 10 1/2" 1 1/2"
6' - 1 1/2"
1' - 0 3/8" 1' - 0"
/2
/2
/2
1 1/2" 10 1/2" 1 1/2"
6' - 1 3/8"
1 1/2" 10 1/2" 1 1/2"
/2
/2
/2
7' - 1 1/2"
10 1/2" 1 1/2"
/2
/2
/2
1 1/2"
8' - 1 1/2"
8' - 1 1/2"
/4
1 1/2" 1 1/2"10 1/2"
/2
9' - 1 1/2"
/2
/2
7' - 1 3/8"
07/01/26
00404366C O
LO
RADO L ICENS
E
D
A
RC H I T ECT
SE
A
N
M. F ITZPATR
ICK
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
N/A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
7 8 9 10321 4 5 6
07/01/2026
National Cemetery Administration
Design and Construction Service
JD Engineering, PC 371 Zimmerman Lane
Hamilton, MT 59840
Phone: (406) 218 - 9980
Elgin, OK
N/A
U.S. Department of Veterans Affairs
BID DOCUMENTS FORT SILL
GRAVESITE EXPANSION AND
CEMETERY FCA IMPROVEMENTSJD Engineering, PC 371 Zimmerman Lane
Hamilton, MT 59840
Phone: (406) 218 - 9980
720.491.7559; Sean Fitzpatrick
56 LOUIS PRIMA DRIVE, SUITE B, COVINGTON, LA 70433
Location
920CM3006
Approved: Project Manager/COR Department of Veteran Affairs, NCA POC: Homayoun Kazemipour Email: homayoun.kazemipour@va.gov
A-503
NICHE UNITS DETAILS
SF BP
3/4" = 1'-0" D4
4H X 9W NICHE UNIT
3/4" = 1'-0"
D2
4H X 8W NICHE UNIT
3/4" = 1'-0" D1
4H X 4W NICHE UNIT
3/4" = 1'-0" B6
3H X 8W NICHE UNIT
3/4" = 1'-0"
B4
3H X 7W NICHE UNIT
3/4" = 1'-0" B1
3H X 5W NICHE UNIT
3/4" = 1'-0"
B8
3H X 9W NICHE UNIT
3/4" = 1'-0" F2
4H X 8W NICHE UNIT
3/4" = 1'-0"
F1
4H X 4W NICHE UNIT
3/4" = 1'-0" C1
3H X 5W NICHE UNIT
3/4" = 1'-0"
C8
3H X 9W NICHE UNIT
3/4" = 1'-0" C6
3H X 8W NICHE UNIT
3/4" = 1'-0"
C4
3H X 7W NICHE UNIT
3/4" = 1'-0" B2
3H X 6W NICHE UNIT
3/4" = 1'-0" C2
3H X 6W NICHE UNIT
3/4" = 1'-0" F6
5H X 7W NICHE UNITS
3/4" = 1'-0"
F8
5H X 8W NICHE UNIT
3/4" = 1'-0" D8
5H X 8W NICHE UNIT
3/4" = 1'-0" F4
4H X 9W NICHE UNIT
3/4" = 1'-0" D6
5H X 7W NICHE UNIT
KEYNOTE LEGEND
TYPE
MARK KEYNOTE
1 PRECAST CONCRETE COLUMBARIUM
UNIT
2 RECESSED ANCHOR BOLTS
3 NICHE TOP WELD PLATES
4 REINFORCING PER MANUF. AND
SPECIFICATION REQUIREMENTS.
5 LIFTING INSERT PER MANUF. AND
SPECIFICATION REQUIREMENTS.
5 5 5 5 5
333 3
3 333 33
33 33 33 33 33
22 22
2 2
2 2 2 2 22 22
3 33 3
33 33 33
33 1
1 1 1 1
1 1 1
44444
TYP
3/16
PLAN DETAIL
4A -TOP
PLAN DETAIL
4B -SIDEWALL
6"9"
1 _ 2
6"
PREDRILLED
HOLE, TYP.
MARBLE
NOTE: MARBLE NICHE COVER GOVERNMENT FURNISHED
1_
3 _ 4
1_
1 _ 4
1 _ 4
1_
1_
1 _ 4
1_
1 _ 4
PLAN
3/8" JOINT
PRECAST CONCRETE
COLUMBARIUM UNIT
MARBLE NICHE COVER - TYP.
SEALANT COLOR TO MATCH
PRE-CAST COLUMBARIUM UNIT
COMPRESSED FOAM BACKER
ROD
BACKER ROD AND SEALANT
NICHE COVER
-1
/2
R E
A R
F R
O N
T -1
/2
2" 20" 3/4"
-3
/4
7/8"
7/8"
/8
/8
/8
NICHE
COVER
SEE DETAIL "A"
SEE DETAIL "B"
CAST IN PLACE
FASTENER HOLE
NICHE
CAST IN PLACE
FASTENER HOLE
NOTE: CONTRACTOR IS RESPONSIBLE TO ENSURE NO INTERFERENCE
BETWEEN ROSETTE BOLT AND CARRIAGE BOLT INSTALLATION
1_
" COVER
1_
5_
7_
7_
"1 5_ " 3_
3_
" 1 1_
1 _ 2
T O
IN
S
ID
E
N
IC
H E
F
R O
N T
1 _ 2
IN
S
ID
E
N
IC
H E
B
A C
K
3_
" OVERLAP
3 _ 4
C
O V
E R
3 _ 4
T Y
P
IC
A L G
A P
3 _ 8
O V
E R
L A
P
W/O COVERW/O COVER
WITH COVER
BOTTOM OF UNIT
(4) 3/8" ∅ HOLES
IN NICHE COVER
STAINLESS STEEL ROSETTE
STAINLESS STEEL TAMPER
PROOF TORX HEAD SCREW
WHITE NEOPRENE WASHER
NICHE COVER
STAINLESS STEEL BOLT & HEX
NUT 1/4"-20 UNC X 2 1/2" LONG
STAINLESS STEEL WASHER &
LOCKWASHER
PLASTIC SHIM WASHER
STAINLESS STEEL
WASHER
STAINLESS STEEL
CLIP ANGLE
STAINLESS STEEL
SPRING CLIP
STAINLESS STEEL TAMPER
PROOF TORX HEAD SCREW
STAINLESS STEEL
ROSETTE
WHITE NEOPRENE
WASHER
NICHE
1/4" DIA. HOLE CAST-IN-PLACE
3/4" DIA. NEOPRENE WASHER
3/8"
OVERLAP
(TYP)
MARBLE NICHE COVER
W/PRE-DRILLED 3/8" DIA.
HOLES TO ACCEPT
ROSETTE&
BOLT.
WHITE NEOPRENE WASHER
STAINLESS STEEL
ROSETTE
STAINLESS STEEL TAMPER
PROOF TORX HEAD SCREW
STAINLESS
STEEL
SPRING CLIP
STAINLESS STEEL
WASHER
& LOCKWASHER
NICHE
PLASTIC
SHIM
WASHER
STAINLESS STEEL
RECESSED CARRIAGE BOLT
& HEX NUT 1_
- 20 UNC X 2"
LONG
ALL EXPOSED CONCRETE (NICHE
FRONTS) SHALL BE GROUND OR
PATCHED SMOOTH; APPLY 2 COATS
SPECIFIED HIGH BOND SEALER TO
MATCH EXISTING
1/4" DIA. HOLE CAST-IN-PLACE3/8"
OVERLAP
(TYP)
1-1/4"
-1
/4
/4
/1
S L O
T
3/4" SLOT
ON ℄
7/8"
1-1/2"
5/16" SLOT
/4
S
L O
T O
N
1-1/2"
-1
/4
STAINLESS STEEL
THREADED
SPRING CLIP TO RECEIVE
TORX HEAD SCREW
1"∅
STAINLESS STEEL
TAMPER PROOF
TORX HEAD
SCREW
316 STAINLESS STEEL
ROSETTE BRUSHED
(MATTE) FINISH
WHITE
NEOPRENE
WASHER
STAINLESS STEEL
TORX HEAD BOLT
TAMPER PROOF
#10-24UNC X 1
BOLT LENGTH TO BE
CHOSEN THAT DOES NOT
INTERFERE WITH CARRIAGE
BOLT INSTALLATION
07/01/26
00404366C O
LO
RADO L ICENS
E
D
A
RC H I T ECT
SE
A
N
M. F ITZPATR
ICK
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
N/A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
7 8 9 10321 4 5 6
07/01/2026
National Cemetery Administration
Design and Construction Service
JD Engineering, PC 371 Zimmerman Lane
Hamilton, MT 59840
Phone: (406) 218 - 9980
Elgin, OK
N/A
U.S. Department of Veterans Affairs
BID DOCUMENTS FORT SILL
GRAVESITE EXPANSION AND
CEMETERY FCA IMPROVEMENTSJD Engineering, PC 371 Zimmerman Lane
Hamilton, MT 59840
Phone: (406) 218 - 9980
720.491.7559; Sean Fitzpatrick
56 LOUIS PRIMA DRIVE, SUITE B, COVINGTON, LA 70433
Location
920CM3006
Approved: Project Manager/COR Department of Veteran Affairs, NCA POC: Homayoun Kazemipour Email: homayoun.kazemipour@va.gov
A-504
NICHE DETAILS
Checker BP
3/4" = 1'-0" C1
TYPICAL WELD PLATE DETAILS
3" = 1'-0" E1
COLUMBARIUM NICHE COVER DETAIL
1 1/2" = 1'-0" F1
NICHE JOINT DETAIL
6" = 1'-0" D4
SECTION THRU NICHE
3" = 1'-0" F4
NICHE PLATE ASSEMBLY SEQUENCE
12" = 1'-0" B8
DETAIL A
12" = 1'-0" C8
DETAIL B
12" = 1'-0" E8
S.S. CLIP ANGLE ASSEMBLY
12" = 1'-0" F8
S.S. CLIP ASSEMBLY ISO & ROSETTE
FRAME TYPES
1-HM
1-AL
SINGLE
SC
H
ED
2"
2" SCHED 2"
F-WD
F-HM
1-F
(SINGLE FLUSH)
DOOR TYPES
3-HM
3-AL
DOUBLE
4"
2" SCHED 2"
AS SCHD AS SCHD
AS
S
C H
D
AS
S
C H
D
3-LV
(DOUBLE LOUVERED)
F-STL
LV-WD
LV-HM
LV-STL
1-STL 3-STL
ENTRY SLAB
EXPANSION JOINT
STOP STRIP
ALUMINIUM ABA
COMPLIANT THRESHOLD
DOOR AS SCHEDULED
HOLLOW METAL DOOR
FRAME
5/8" [16mm] GYPSUM
R-13 BATT INSULATION
BOARD
BOARD
REFER STRUCTURAL
WOOD HEADER,
5/8" [16mm] GYPSUM
"J" MOLD, TYPICAL
"J" MOLD, TYPICAL
SCHEDULED
DOOR FRAME
DOOR AS
HOLLOW METAL
"J" MOLD, TYPICAL
2" x 4" [51mm x 102mm]
WOOD STUDS @ 16"
[406mm] O.C.5/8" [16mm]
GYPSUM BOARD
5/8" [16mm] GYPSUM
BOARD
SOUND ATTENUATION
BATTS, AS SCHEDULED
2X4 BASEPLATE
SCHEDULED FLOOR
2X4 WOOD STUDS
2X4 TOP PLATES
SCHEDULED CEILING
UNDERSIDE OF
STRUCTURE
5/8" GWB
3/4" PLYWOOD
BACKERBOARD
TR
4" RUBBER BASE.
SEE DETAIL F3/A-601
3/4" PLYWOOD
BACKERBOARD
4"
1"NOM
2"NOM 2"NOM
1"
EXISTING STL LINTELS
STL FRAME GROUTED FULL
THIS HEADER DETAIL FOR
MASONRY OPENINGS OVER
5'-4" WIDE
VARIES EXISTING CMU WALL
REVERSE FRAME
AS REQD TO
ACCOMMODATE
DOOR SWING
DOOR
2"
1"NOM
2" 2"
1"
STL FRAME
VARIES
RETROFIT MASONRY
ANCHOR
GROUT JAMB FULL
EXISTING CMU WALL
RUNNER WHICHEVER IS LESS
8" OR 1/4 LENGTH OF THE END
PARTITION / STRUCTURAL
ELEMENT
EMBED @ CONC.
1 1/4" MIN.
MIN.
1/2"
2 1/4" X 7/8" X GA. GALV.
ANGLE W/ #8 SMS @ 16" O.C.
OR .145Ø SHOT PINS @ 16"
O.C. @ CONC. WALL 1-1/4"
MIN. EMBED
WIRE TIES
8 GA. HANGER WIRE
W/ 3 TURNS WITHIN
1-1/2" 8 GA. HANGER
WIRE W/ 3 TURN
WITHIN 1-1/2"
1 1/2" X 1.12 #/FT.
MIN. MAIN RUNNER
@ 4'-0" O.C. MAX.
WALL FINISH
GYP. BD.
(1) S-12 SMS @ EA. CHANNEL
TAPE ALL JOINTS AND FINISH AS SPECIFIED
7/8" 26 GA. MIN. HAT CHANNEL
8" MAX. OR 1/4 OF LENGTH OF THE END
RUNNER WHICHEVER IS LESS
PARTITION / STRUCTURAL
ELEMENT
EMBED @ CONC.
1 1/4" MIN
MIN.
1/2"
1 3/8" X 7/8" X GA. GALV.
ANGLE W/ ATTACHMENT TO
STRUCTURE NOT FINISH W/ (1)
#8 SMS @ 16"O.C. OR
SHOT .145 DIA PINS @ 16" O.C.
@ CONC. WALL 1 1/4" MIN.
EMBED.
8 GA. HANGER WIRE W/
3 TURNS WITHIN 1-1/2"
1 1/2" X 1.12 #/FT. MIN.,
MAIN RUNNER @ 4'- 0"
O.C. MAX.
(1) S-12 SMS @ EA. CHANNEL
7/8" 26 GA. MIN HAT
CHANNEL
GYP. BD.
WALL FINISH
TAPE ALL JOINTS AND FINISH AS SPECIFIED
M
AX
1/ 2"
WALL FACE: SEE PLANS FOR
PARTITION TYPE
FINISH FLOORING
4" COVED RUBBER BASE
CONCRETE SLAB
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
BID DOCUMENTS
N/A
National Cemetery Administration
Design and Construction Service
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
FORT SILL
GRAVESITE EXPANSION AND
CEMETERY FCA IMPROVEMENTS
Elgin, OK
920CM3006
N/A
07/01/2026Revisions: Date: JV
Approved: Project Manager/COR Department of Veteran Affairs, NCA POC: Homayoun Kazemipour Email: homayoun.kazemipour@va.gov
720.491.7559; Sean Fitzpatrick
56 LOUIS PRIMA DRIVE, SUITE B, COVINGTON, LA 70433 JB
JD Engineering, PC 371 Zimmerman Lane Hamilton, MT 59840 Phone: (406) 218 - 9980
No. 44593
PROFESSIONAL
REGISTERED
JORDAN D. VANDERMEE
RENGINEER
SF DH
DOORS, ROOM FINISH SCHEDULES
AND DETAILS
A-601
Door Schedule
Building Name
To Room:
Name
Door
Type
Door Frame Hardware
CommentsMark Size
Material Finish Material Type Finish Head Jamb Sill Set No.Width Height Thickness
Committal Shelter Storage 001 6' - 0" 7' - 0" 0' - 1 3/4" STL P STL 3-STL P S-1 HW-E63-LV
NTS
SILL S-1 DETAILF1
3" = 1'-0"
DOOR JAMB DETAIL - INTERIORC33" = 1'-0"
DOOR HEAD DETAIL - INTERIORC1
Admin-Maint Building
TR 101 3' - 0" 8' - 0" 0' - 1 3/4" WD P HM 1-HM P - HW-51-F C1/A-601 C3/A-601
DIMENSIONS TO BE FIELD VERIFIED. DOORS
TO BE REPLACED FOR BOTH SHELTERS
E1/A-601 E3/A-601
3" = 1'-0"
WALL TYPE- P01B5
ROOM FINISH SCHEDULE
Name Number Floor Finish Base Finish Wall Finish Ceiling Finish Comments
TR 101A SDT RB P-1 P-1/GYP
ROOM FINISH LEGEND
SDT - STATIC DISSIPATIVE VINYL TILE
RB - RUBBER BASE
P - PAINT
P/GYP- PAINTED GYPSUM BOARD CEILING
SEE 09 06 00 FOR FINISHES
SPECIFICATIONS
3" = 1'-0"
DOOR JAMB DETAIL - CMUE33" = 1'-0"
DOOR HEAD DETAIL - CMUE1
P-1 - HIGH GLOSS WHITE PAINT
HONOR GUARD 101 EXT EXT P-2 EXT P-2 - MATCH EXISTING PAINT
N.T.S
GYP PERIMETER PARALLEL TO MAIN RUNNERD5 N.T.S
GYP PERIMETER PERPENDICULAR TO MAIN RUNNERD7
N.T.S
ROOM SIGNAGE EXAMPLEB7
00404366CO
LO
RADO L ICENSED
ARCH I T ECT
SE
AN
M. FITZPATRICK
07/01/26
NTS
BASE DETAILF3
KEY AND CORE SYSTEM SHALL MATCH
EXISTING.
12/30/2026
W4
EX
IS
TI
N
G
1' -9
5'
-5
3'-4"
6"
3'-4"
W5
EX
IS
TI
N
G
4' -1
0" 2'
-4
2'-4"
W7
FINISH FLOOR2'
-1
0"
EX
IS
TI
N
G
4'-0"
WINDOW TYPES
W1
EX
IS
TI
N
G 5'-9"
2'-8" 5"
2'-8" 2'
-6
5' -9
2" 2" 2"2"
4' -4
EX
IS
TI
N
G
2' -6
4'
-9
3'-4"
EX
IS
TI
N
G
1' -9
/4
3'-9"
W8 W10W6
EX
IS
TI
N
G
4' -1
0" 2'
-4
4'-6"
15lb. BUILDING PAPER
ALUMINUM
INSULATING GLASS
WINDOW WITH 1" [25mm]
METAL FLASHING
1/2" PLYWOOD
ALUMINUM TRIM COIL EXISTING HEADER
EXISTING GYPSUM BOARD
PAINTED 3/4"
FILL WITH FIBERGLASS
SEALANT WITH BACKER
INSULATION
PRIME FJ PINE WOOD TRIM
SEALANT WITH BACKER
ROD
ROD, TYPICAL
WITH DRIP EDGE
STONE VENEER
ALUMINUM TRIM COIL
ALUMINUM SILL
PRIME FJ PINE WOOD TRIM
WOOD REVEAL
SEALANT WITH BACKER ROD
PAINTED 3/4" [19mm]
FILL WITH FIBERGLASS
INSULATION
INSULATING GLASS
WINDOW WITH 1" [25mm]
ALUMINUM
EXISTING GYPSUM BOARD
EXISTING INSULATION
EXISTING WOOD STUDS
15lb. BUILDING PAPER
1/2" [13mm] PLYWOOD
DOUBLE STUDS AT
JAMBS - EXISTING
SLOPE
EXISTING R-19 BATT INSULATION
EXISTING 5/8" [16mm] GYPSUM
1/2" [13mm] PLYWOOD
SILL, TYPICAL
PAINTED 3/4" [19mm]
FILL WITH FIBERGLASS
EXISTING DOUBLE STUDS AT
INSULATION
GALVANIZED METAL
FLASHING
24" [609mm] O.C.
WEEP HOLES AT
CONCRETE MASONRY
ALUMINUM WINDOW WITH
EXISTING PRE CAST
ALUMINUM SUB SILL
ALUMINUM PANNING
1" [25mm] INSULATING GLASS
TRIM BEYOND
METAL FLASHING
BOARD
"J" MOLD, TYPICAL
TRIM SCRIBE TO WINDOW
1 1/4" [32mm] WOOD
FILL WITH FIBERGLASS
EXISTING 2" x 6" [51mm x 152mm] WITH 1/2" [13mm] PLYWOOD
INSULATION
FLITCH PLATE IN-BETWEEN
ALUMINUM
WINDOW WITH 1" [25mm]
INSULATING GLASS
R O
U G
H O
PE
N
IN
G
U N
IT
W
ID
TH
0.
R O
U G
H O
PE
N
IN
G
U N
IT
W
ID
TH
6.
0.
ALUMINUM PANNING
TRIM
WOOD REVEAL
PRIME FJ PINE WOOD TRIM
3/4" [19mm] PLYWOOD
3/4" [19mm] PLYWOOD
PAINTED 3/4" [19mm]
PRIME FJ PINE WOOD TRIM
WOOD REVEAL
WOOD REVEAL
BELT COURSE
EXISTING INSULATION
WINDOW WITH 1" [25mm]
INSULATING GLASS
3/4" [19mm] PLYWOOD
ALUMINUM
DRIP FLASHING
PAINTED 3/4" [19mm]
FILL WITH FIBERGLASS SEALANT WITHINSULATION
WOOD TRIM
EXISTING 6" [152mm]
EXISTING GYPSUM
BOARD
GALVANIZED METAL
FLASHING
BACKER ROD
ROD
SEALANT WITH BACKER
BOARD
WOOD TRIM
PAINTED 3/4" [63mm]
5/8" [16mm] GYPSUMEXISTING INSULATION
EXISTING CMU WALL
EXISTING GYPSUM
BOARD
EXISTING STONE VENEER
3/4" [19mm] PLYWOOD
ALUMINUM
INSULATING GLASS
WINDOW WITH 1" [25mm]
1"
3/4"
ALUMINUM
INSULATING GLASS
WINDOW WITH 1" [25mm]
SEALANT WITH
BACKER ROD
EXISTING CMU WALL
PAINTED 3/4" [63mm]
WOOD TRIM
BOARD
EXISTING GYPSUM
STONE VENEER
PRE CAST CONCRETE
MASONRY BELT COURSE
WEEP HOLES AT
24" [609mm] O.C.
FLASHING WITH
GALVANIZED METAL
DRIP EDGE
PLYWOOD SUB SILL
EXISTING WOOD STUDS
TOP OF SILL
2'-6" [762mm]
0.75
EXISTING WOOD STUDS
PREFINISHED ALUM.
SUB SILL
3.5" 1.5"
STONE ANCHOR
SEALANT WITH BACKER
ROD, TYPICAL
STONE VENEER
STEEL ANGLE
STONE, (BEYOND)
EXISTING GYPSUM
BOARD
3/4" [19mm] PLYWOOD
GALVANIZED METAL
FLASHING
ALUMINUM TRIM COIL
ALUMINUM TRIM COIL
CMU BOND BEAM
ALUMINUM
INSULATING GLASS
WINDOW WITH 1" [25mm]
EXISTING HEADER
EXISTING GYPSUM BOARD
PAINTED 3/4"
FILL WITH FIBERGLASS
SEALANT WITH BACKER
INSULATION
PRIME FJ PINE WOOD TRIM
ROD, TYPICAL
WOOD REVEAL
3/4" [19mm] PLYWOOD
GALVANIZED METAL
FLASHING
ALUMINUM TRIM COIL
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
BID DOCUMENTS
N/A
National Cemetery Administration
Design and Construction Service
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
FORT SILL
GRAVESITE EXPANSION AND
CEMETERY FCA IMPROVEMENTS
Elgin, OK
920CM3006
N/A
07/01/2026Revisions: Date: JV
Approved: Project Manager/COR Department of Veteran Affairs, NCA POC: Homayoun Kazemipour Email: homayoun.kazemipour@va.gov
720.491.7559; Sean Fitzpatrick
56 LOUIS PRIMA DRIVE, SUITE B, COVINGTON, LA 70433 JB
JD Engineering, PC 371 Zimmerman Lane Hamilton, MT 59840 Phone: (406) 218 - 9980
No. 44593
PROFESSIONAL
REGISTERED
JORDAN D. VANDERMEE
RENGINEER
SF JP
WINDOWS SCHEDULE AND DETAILS
A-602
3" = 1'-0"
HEAD DETAIL.D1 3" = 1'-0"
JAMB DETAIL.D3
Window Schedule Type Mark
Size Type Material Finish
Detail Glazing Head Height CommentsWidth Height Head Jamb Sill Thickness Type
W1 2' - 8" 5' - 9"" B8/A-602 D3/A-602 D6/A-602 8' - 3" W4 3' - 4" 5' - 5" 7' - 0" W5 2' - 4" 2' - 4" 9' - 0"
W7 4' - 0" 4' - 4" 7' - 0"
3" = 1'-0"
SILL DETAIL.D6 3" = 1'-0"
MULLION DETAIL.D9
D1/A-602 D3/A-602 D6/A-602 D1/A-602 D3/A-602 D6/A-602
D1/A-602 D3/A-602 D6/A-602
ALUMINUMDOUBLE HUNG
AWNING
FIXED
SLIDING
ALUMINUM
ALUMINUM
ALUMINUM
INSULATED MATCH EXISTING1"
1" 1"
1"
3" = 1'-0"
HEAD @ SOFFIT DETAIL.F1 3" = 1'-0"
JAMB DETAIL.F5 3" = 1'-0"
SILL DETAIL.F8
W8 W10
3' - 4" 4' - 9" DOUBLE HUNG
3' - 9" 1' - 9 3/4" AWNING
ALUMINUM
ALUMINUM
F1/A-602 F5/A-602 F8/A-602 F7/A-602 F5/A-602 F8/A-602
7' - 3" 7' - 3"
1" 1"
3" = 1'-0"
HEAD - LINTEL DETAILF7
3" = 1'-0"
HEAD @ SOFIT DETAIL.B8
ALL DIMENSIONS TO BE FIELD VERIFIED. WINDOWS STYLES, OPERATIONS, GLAZING AND FINISHES TO MATCH EXISTING
Insect Screening
Screen Mesh
Screen Mesh
Screen Mesh Screen Mesh Screen Mesh
HIGH PERFORMANCE COATING SYSTEM
HIGH PERFORMANCE COATING SYSTEM
HIGH PERFORMANCE COATING SYSTEM
HIGH PERFORMANCE COATING SYSTEM
HIGH PERFORMANCE COATING SYSTEM
HIGH PERFORMANCE COATING SYSTEM
COUNT
00404366CO
LO
RADO L ICENSED
ARCH I T ECT
SE
AN
M. FITZPATRICK
07/01/26
ALL DIMENSIONS TO BE FIELD VERIFIED. WINDOWS STYLES, OPERATIONS, GLAZING AND FINISHES TO MATCH EXISTING ALL DIMENSIONS TO BE FIELD VERIFIED. WINDOWS STYLES, OPERATIONS, GLAZING AND FINISHES TO MATCH EXISTING
ALL DIMENSIONS TO BE FIELD VERIFIED. WINDOWS STYLES, OPERATIONS, GLAZING AND FINISHES TO MATCH EXISTING ALL DIMENSIONS TO BE FIELD VERIFIED. WINDOWS STYLES, OPERATIONS, GLAZING AND FINISHES TO MATCH EXISTING ALL DIMENSIONS TO BE FIELD VERIFIED. WINDOWS STYLES, OPERATIONS, GLAZING AND FINISHES TO MATCH EXISTING
INSULATED MATCH EXISTING
INSULATED MATCH EXISTING
INSULATED MATCH EXISTING
INSULATED MATCH EXISTING
INSULATED MATCH EXISTING
W6 4' - 6" 2' - 4" AWNING 9' - 0"D1/A-602 D3/A-602 D6/A-602ALUMINUM 1" Screen MeshHIGH PERFORMANCE COATING SYSTEM 2INSULATED MATCH EXISTING ALL DIMENSIONS TO BE FIELD VERIFIED. WINDOWS STYLES, OPERATIONS, GLAZING AND FINISHES TO MATCH EXISTING
12/30/2026
GENERAL NOTES
I. GENERAL CONDITIONS
A. DESIGN LOADS ARE AS FOLLOWS:
DESIGN WIND PRESSURE: P = (Ce)(Cq)(qs)(I)
EXPOSURE COEFFICIENT: EXPOSURE "C"
Ce = 1.06 (0-15 FT.)
PRESSURE COEFFICIENT:
Cq = 1.2 WALLS (INWARD AND OUTWARD)
STAGNATION PRESSURE: 80 MPH
qs = 16.4 PSF
IMPORTANCE FACTOR:
I = 1.0
B. STRUCTURE DESIGNED IN ACCORDANCE WITH THE INTERNATIONAL BUILDING
CODE, 2024 EDITION.
C. CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO START OF
CONSTRUCTION.
D. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF OTHER
TRADES PRIOR TO FABRICATION AND INSTALLATION
OF MATERIALS.
E. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF
ARCHITECTURAL AND STRUCTURAL DRAWINGS PRIOR TO FABRICATION,
FORMING, OR PLACEMENT OF MATERIALS. GENERAL CONTRACTOR SHALL
REPORT DISCREPANCIES IMMEDIATELY TO COR AND SHALL PROCEED
WITH CONSTRUCTION ONLY AFTER DISCREPANCY HAS BEEN RESOLVED.
F. THE DETAILS DESIGNATED AS "TYPICAL DETAILS" APPLY GENERALLY TO THE
DRAWINGS IN ALL AREAS WHERE CONDITIONS ARE SIMILAR TO THOSE SHOWN
IN THE DETAILS
G. CONTRACTOR SHALL REVIEW ARCHITECTURAL SHEETS FOR
MISCELLANEOUS STEEL.
II. SITE
III. CONCRETE (SEE SPEC SECTION 03 30 53)
A. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 4500 PSI AT
28 DAYS.
B. REINFORCING STEEL SHALL BE ASTM A615 GRADE 60 UNLESS NOTED
OTHERWISE.
C. LAP ALL REINFORCING SPLICES 30 BAR DIAMETERS WITH 24" MINIMUM
UNLESS NOTED OTHERWISE.
D. PROVIDE CORNER BARS WITH 30 BAR DIAMETER LAP TO MATCH HORIZONTAL
REINFORCEMENT AT ALL GRADE BEAM AND WALL INTERSECTIONS. 2'-0" LAP
MINIMUM.
E. ALL REINFORCEMENT SHALL BE DETAILED IN ACCORDANCE WITH THE LATEST
ACI DETAILING MANUAL.
F. CONTRACTOR SHALL COORDINATE ALL PENETRATIONS, CONDUIT, CHAMFERS AND
EMBEDDED ITEMS PRIOR TO CONCRETE PLACEMENT.
A. PLACEMENT OF FILL SHALL BE IN ACCORDANCE WITH GEOTECHNICAL REPORT
BY TERRACON, PROJECT NO. 03255051, DATED DECEMBER 5, 2025 AND SPEC SECTION 31 20 11.
SEIMIC ZONE 2A
Z = 0.15
SOIL PROFILE TYPE SD.
SOIL BEARING PRESSURE: 1,500 PSF
G. CEMENT SHALL BE TYPE V SULFATE RESISTANT.
G. CONCRETE SHALL HAVE 3" MAX SLUMP.
B. ALL FOOTINGS ARE TO BE INSTALLED ON 9" ODOT TYPE 'A' AGGREGATE BASE OVER
TENSAR TRIAX GEOGRID (TX7) OR EQUAL OVER 8 OZ/SY NONWOVEN GEOTEXTILE FILTER FABRIC.
14'-6" 10'-0" 56'-10 3/4" 36'-7 1/2"
'-6
'-0
'-1
/1 6"
'-7
/2
37'-0 9/16" 27'-10 3/8"29'-5 5/16"
'-5
/1
6"
'-0
10'-0" 3'-2"
'-0
3'
-2
F3 A-301
F3 A-301
F3 A-301
F3 A-301
F8 A-301
F8 A-301
F8 A-301
F8 A-301
F1 A-301
F1 A-301
F1 A-301
F6 A-301
F6 A-301
F1 A-301
2' -2
4' -2
F3 A-301
2'-2"
4'-2"
4' -2
2' -2
3'
-2
4'-2"
3'-2" 2'-2"
4' -0
3'
-0
5' -0
5'-0"
3'-0" 4'-0"
3 2
2 1
0 5'
3/16 INCH = 1 FOOT
10'1'
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
BID DOCUMENTS
N/A
National Cemetery Administration
Design and Construction Service
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
FORT SILL
GRAVESITE EXPANSION AND
CEMETERY FCA IMPROVEMENTS
Elgin, OK
920CM3006
N/A
07/01/2026Revisions: Date: JV
Approved: Project Manager/COR Department of Veteran Affairs, NCA POC: Homayoun Kazemipour Email: homayoun.kazemipour@va.gov
720.491.7559; Sean Fitzpatrick
56 LOUIS PRIMA DRIVE, SUITE B, COVINGTON, LA 70433 JB
JD Engineering, PC 371 Zimmerman Lane Hamilton, MT 59840 Phone: (406) 218 - 9980
No. 44593
PROFESSIONAL
REGISTERED
JORDAN D. VANDERMEE
RENGINEER
DHSF
S-101
COLUMBARIUM C FOUNDATION
PLAN
KEYED NOTESKEYED NOTES
1. CAST IN PLACE CONCRETE STEM WALL UNDER NICHES
UNITS
2. CAST IN PLACE CONCRETE FOUNDATION
3. 1 FOOT DEPTH CAST IN PLACE CONTINUOUS CONCRETE
FOOTING
4. CAST IN PLACE CONCRETE COLUMN
CO
LO
RADO L ICENSED
ARCH I T ECT
SE
AN
M. FITZPATRICK
07/01/26
AutoCAD SHX Text
SCALE: 3/16" = 1'-0"
AutoCAD SHX Text
FOUNDATION PLAN SECTION C
AutoCAD SHX Text F3
AutoCAD SHX Text 12/30/2026
GENERAL NOTES
I. GENERAL CONDITIONS
A. DESIGN LOADS ARE AS FOLLOWS:
DESIGN WIND PRESSURE: P = (Ce)(Cq)(qs)(I)
EXPOSURE COEFFICIENT: EXPOSURE "C"
Ce = 1.06 (0-15 FT.)
PRESSURE COEFFICIENT:
Cq = 1.2 WALLS (INWARD AND OUTWARD)
STAGNATION PRESSURE: 80 MPH
qs = 16.4 PSF
IMPORTANCE FACTOR:
I = 1.0
B. STRUCTURE DESIGNED IN ACCORDANCE WITH THE INTERNATIONAL BUILDING
CODE, 2024 EDITION.
C. CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO START OF
CONSTRUCTION.
D. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF OTHER
TRADES PRIOR TO FABRICATION AND INSTALLATION
OF MATERIALS.
E. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF
ARCHITECTURAL AND STRUCTURAL DRAWINGS PRIOR TO FABRICATION,
FORMING, OR PLACEMENT OF MATERIALS. GENERAL CONTRACTOR SHALL
REPORT DISCREPANCIES IMMEDIATELY TO COR AND SHALL PROCEED
WITH CONSTRUCTION ONLY AFTER DISCREPANCY HAS BEEN RESOLVED.
F. THE DETAILS DESIGNATED AS "TYPICAL DETAILS" APPLY GENERALLY TO THE
DRAWINGS IN ALL AREAS WHERE CONDITIONS ARE SIMILAR TO THOSE SHOWN
IN THE DETAILS
G. CONTRACTOR SHALL REVIEW ARCHITECTURAL SHEETS FOR
MISCELLANEOUS STEEL.
II. SITE
III. CONCRETE (SEE SPEC SECTION 03 30 53)
A. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 4500 PSI AT
28 DAYS.
B. REINFORCING STEEL SHALL BE ASTM A615 GRADE 60 UNLESS NOTED
OTHERWISE.
C. LAP ALL REINFORCING SPLICES 30 BAR DIAMETERS WITH 24" MINIMUM
UNLESS NOTED OTHERWISE.
D. PROVIDE CORNER BARS WITH 30 BAR DIAMETER LAP TO MATCH HORIZONTAL
REINFORCEMENT AT ALL GRADE BEAM AND WALL INTERSECTIONS. 2'-0" LAP
MINIMUM.
E. ALL REINFORCEMENT SHALL BE DETAILED IN ACCORDANCE WITH THE LATEST
ACI DETAILING MANUAL.
F. CONTRACTOR SHALL COORDINATE ALL PENETRATIONS, CONDUIT, CHAMFERS AND
EMBEDDED ITEMS PRIOR TO CONCRETE PLACEMENT.
A. PLACEMENT OF FILL SHALL BE IN ACCORDANCE WITH GEOTECHNICAL REPORT
BY TERRACON, PROJECT NO. 03255051, DATED DECEMBER 5, 2025 AND SPEC SECTION 31 20 11.
SEIMIC ZONE 2A
Z = 0.15
SOIL PROFILE TYPE SD.
SOIL BEARING PRESSURE: 1,500 PSF
G. CEMENT SHALL BE TYPE V SULFATE RESISTANT.
G. CONCRETE SHALL HAVE 3" MAX SLUMP.
B. ALL FOOTINGS ARE TO BE INSTALLED ON 9" ODOT TYPE 'A' AGGREGATE BASE OVER
4' -0
37'-3"
3'-0"
'-1
3/
8"
37'-3 1/2"
'-1
7/
8"
'-5
/8
4'-0"10'-1 5/8"31'-0"29'-9 7/8"
'-0
/8
'-8
/8
'-1
1/
8"
4' -0
3' -0
5' -0
F4 A-302
F8 A-302
F8 A-302
F8 A-302
F4 A-302
F4 A-302
3'-0"
5'-0"
F8 A-301
F6 A-301
F8 A-301
F6 A-301
F8 A-301
F8 A-301
F6 A-301
3' -0
5' -0
5'-0"
4'-0"
3 2
0 5'
3/16 INCH = 1 FOOT
10'1'
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
BID DOCUMENTS
N/A
National Cemetery Administration
Design and Construction Service
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
FORT SILL
GRAVESITE EXPANSION AND
CEMETERY FCA IMPROVEMENTS
Elgin, OK
920CM3006
N/A
07/01/2026Revisions: Date: JV
Approved: Project Manager/COR Department of Veteran Affairs, NCA POC: Homayoun Kazemipour Email: homayoun.kazemipour@va.gov
720.491.7559; Sean Fitzpatrick
56 LOUIS PRIMA DRIVE, SUITE B, COVINGTON, LA 70433 JB
JD Engineering, PC 371 Zimmerman Lane Hamilton, MT 59840 Phone: (406) 218 - 9980
No. 44593
PROFESSIONAL
REGISTERED
JORDAN D. VANDERMEE
RENGINEER
DHSF
COLUMBARIUM E FOUNDATION
PLAN
S-102
KEYED NOTESKEYED NOTES
1. CAST IN PLACE CONCRETE STEM WALL UNDER NICHES
UNITS
2. CAST IN PLACE CONCRETE FOUNDATION
3. 1 FOOT DEPTH CAST IN PLACE CONTINUOUS CONCRETE
FOOTING
4. CAST IN PLACE CONCRETE COLUMN
CO
LO
RADO L ICENSED
ARCH I T ECT
SE
AN
M. FITZPATRICK
07/01/26
AutoCAD SHX Text
SCALE: 3/16" = 1'-0"
AutoCAD SHX Text
FOUNDATION PLAN SECTION E
AutoCAD SHX Text F3
AutoCAD SHX Text 12/30/2026
4'-0"
'-3
3' -0
27'-10 3/8"
'-3
/2
70'-10 7/8" 37'-5 1/8"
4' -0
'-1
/8
'-0
'-9
/8
10'-0 1/8"29'-8 3/8"36'-10 1/8"
4'-0"
GENERAL NOTES
I. GENERAL CONDITIONS
A. DESIGN LOADS ARE AS FOLLOWS:
DESIGN WIND PRESSURE: P = (Ce)(Cq)(qs)(I)
EXPOSURE COEFFICIENT: EXPOSURE "C"
Ce = 1.06 (0-15 FT.)
PRESSURE COEFFICIENT:
Cq = 1.2 WALLS (INWARD AND OUTWARD)
STAGNATION PRESSURE: 80 MPH
qs = 16.4 PSF
IMPORTANCE FACTOR:
I = 1.0
B. STRUCTURE DESIGNED IN ACCORDANCE WITH THE INTERNATIONAL BUILDING
CODE, 2024 EDITION.
C. CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO START OF
CONSTRUCTION.
D. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF OTHER
TRADES PRIOR TO FABRICATION AND INSTALLATION
OF MATERIALS.
E. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF
ARCHITECTURAL AND STRUCTURAL DRAWINGS PRIOR TO FABRICATION,
FORMING, OR PLACEMENT OF MATERIALS. GENERAL CONTRACTOR SHALL
REPORT DISCREPANCIES IMMEDIATELY TO COR AND SHALL PROCEED
WITH CONSTRUCTION ONLY AFTER DISCREPANCY HAS BEEN RESOLVED.
F. THE DETAILS DESIGNATED AS "TYPICAL DETAILS" APPLY GENERALLY TO THE
DRAWINGS IN ALL AREAS WHERE CONDITIONS ARE SIMILAR TO THOSE SHOWN
IN THE DETAILS
G. CONTRACTOR SHALL REVIEW ARCHITECTURAL SHEETS FOR
MISCELLANEOUS STEEL.
II. SITE
III. CONCRETE (SEE SPEC SECTION 03 30 53)
A. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 4500 PSI AT
28 DAYS.
B. REINFORCING STEEL SHALL BE ASTM A615 GRADE 60 UNLESS NOTED
OTHERWISE.
C. LAP ALL REINFORCING SPLICES 30 BAR DIAMETERS WITH 24" MINIMUM
UNLESS NOTED OTHERWISE.
D. PROVIDE CORNER BARS WITH 30 BAR DIAMETER LAP TO MATCH HORIZONTAL
REINFORCEMENT AT ALL GRADE BEAM AND WALL INTERSECTIONS. 2'-0" LAP
MINIMUM.
E. ALL REINFORCEMENT SHALL BE DETAILED IN ACCORDANCE WITH THE LATEST
ACI DETAILING MANUAL.
F. CONTRACTOR SHALL COORDINATE ALL PENETRATIONS, CONDUIT, CHAMFERS AND
EMBEDDED ITEMS PRIOR TO CONCRETE PLACEMENT.
A. PLACEMENT OF FILL SHALL BE IN ACCORDANCE WITH GEOTECHNICAL REPORT
BY TERRACON, PROJECT NO. 03255051, DATED DECEMBER 5, 2025 AND SPEC SECTION 31 20 11.
SEIMIC ZONE 2A
Z = 0.15
SOIL PROFILE TYPE SD.
SOIL BEARING PRESSURE: 1,500 PSF
G. CEMENT SHALL BE TYPE V SULFATE RESISTANT.
G. CONCRETE SHALL HAVE 3" MAX SLUMP.
B. ALL FOOTINGS ARE TO BE INSTALLED ON 9" ODOT TYPE 'A' AGGREGATE BASE OVER
TENSAR TRIAX GEOGRID (TX7) OR EQUAL OVER 8 OZ/SY NONWOVEN GEOTEXTILE FILTER FABRIC.
3'-0"
5'-0"
F4 A-302
F8 A-302
F8 A-302
F8 A-302
F4 A-302
F4 A-302
3' -0
5' -0
F8 A-301
F6 A-301
F8 A-301
F6 A-301
F8 A-301
F8 A-301
F6 A-301
3'-0"
5'-0"
5' -0
4' -0
3 2
0 5'
3/16 INCH = 1 FOOT
10'1'
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
BID DOCUMENTS
N/A
National Cemetery Administration
Design and Construction Service
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
FORT SILL
GRAVESITE EXPANSION AND
CEMETERY FCA IMPROVEMENTS
Elgin, OK
920CM3006
N/A
07/01/2026Revisions: Date: JV
Approved: Project Manager/COR Department of Veteran Affairs, NCA POC: Homayoun Kazemipour Email: homayoun.kazemipour@va.gov
720.491.7559; Sean Fitzpatrick
56 LOUIS PRIMA DRIVE, SUITE B, COVINGTON, LA 70433 JB
JD Engineering, PC 371 Zimmerman Lane Hamilton, MT 59840 Phone: (406) 218 - 9980
No. 44593
PROFESSIONAL
REGISTERED
JORDAN D. VANDERMEE
RENGINEER
DHSF
COLUMBARIUM H FOUNDATION
PLAN
S-103
KEYED NOTESKEYED NOTES
1. CAST IN PLACE CONCRETE STEM WALL UNDER NICHES
UNITS
2. CAST IN PLACE CONCRETE FOUNDATION
3. 1 FOOT DEPTH CAST IN PLACE CONTINUOUS CONCRETE
FOOTING
4. CAST IN PLACE CONCRETE COLUMN
CO
LO
RADO L ICENSED
ARCH I T ECT
SE
AN
M. FITZPATRICK
07/01/26
AutoCAD SHX Text
SCALE: 3/16" = 1'-0"
AutoCAD SHX Text
FOUNDATION PLAN SECTION H
AutoCAD SHX Text F3
AutoCAD SHX Text 12/30/2026
ABBREVIATIONS
DUCTWORK SYMBOLS
ACU
AFF
AD
AHU
AL
BHP
BOD
BTU
BOP
BTUH
CA
CFM
CD
CONT.
COR
CU
D
DX
ENT
EXH
EMCS
FB
°F
FCU
F.G.
FD
FLEX
FPM
FS
FT.
FT
GPM
GPH
HB
HD
IN
HEPA
IU
KW
KWH
MA
MCC
NA
NO.
NIC
OBD
OA
PRV
PSIG
QTY
QUAD
Rh R.A.
RS
RL
ST
SP
RPM
SCD
SDVV
TOPT
TP
TYP.
V
VAC
VAV
VTR
VEL
QUANTITY
QUADRANT
RETURN AIR
REVOLUTIONS PER MINUTE
RELATIVE HUMIDITY
REFRIGERATION LIQUID
REFRIGERATION SUCTION
SMOKE CONTROL DAMPER
SINGLE DUCT VARIABLE VOLUME
STATIC PRESSURE (INCHES OF WATER)
SOUND TRAP
SIDEWALL SUPPLY REGISTER
TOP OF PIPE TRAPEZE
TOTAL PRESSURE (INCHES OF WATER)
TYPICAL
VOLTS
24"x12"
VOLTS, ALTERNATING CURRENT
VARIABLE AIR VOLUME
VENT THRU ROOF
VELOCITY
24"/12"
12"Ø
SD
24x12
12"Ø
24x12Ø
SD
EQUIPMENT SYMBOLS
DUCT MOUNTED SMOKE DETECTOR
XX-##
DUCT MOUNTED STATIC PRESSURE PROBE
ACCESS DOOR
SIDEWALL GRILLE DIMENSION WHERE
SHOWN ON PLANS
T
H
CO2
SEE CONTROL DRAWINGS FOR TYPE
ROOM THERMOSTAT/TEMP. TRANSMITTER LOCATION ONLY
ROOM HUMIDISTAT/HUMIDITY TRANSMITTER LOCATION ONLY
SEE CONTROL DRAWINGS FOR TYPE
ROOM CARBON DIOXIDE TRANSMITTER LOCATION ONLY
SEE CONTROL DRAWINGS FOR TYPE
##x##
XX-#
SYMBOL INDICATES GRILLE OR DIFFUSER
IDENTIFIED IN EQUIPMENT SCHEDULE
CFM
F. SEE SPECIFICATION SECTION 230593, TESTING, ADJUSTING, & BALANCING OR
MECHANICAL SYSTEMS FOR ADDITIONAL DESCRIPTION AND REQUIREMENTS.
G. ALL TEST AND MEASUREMENT TRAVERSE LOCATIONS SHALL BE CLEARLY NOTED ON
FLOOR PLANS WHICH SHALL BE INCLUDED WITH THE TEST AND MEASUREMENT DATA.
H. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF ALL TRADES
INCLUDING MECHANICAL, PLUMBING, ELECTRICAL, FURNITURE, AND ARCHITECTURAL.
ANY DISCREPANCIES SHALL BE REPORTED IMMEDIATELY TO THE ARCHITECT PRIOR
TO START OF WORK.
I. ALL NEW TO EXISTING DUCT CONNECTIONS SHALL BE FIELD VERIFIED PRIOR TO
ORDERING AND FABRICATING NEW DUCTWORK OR DAMPERS
LETTERS REFER TO THE EQUIPMENT TYPE
NUMBERS REFER TO SPECIFIC EQUIPMENT
SYMBOL INDICATES EQUIPMENT IDENTIFIED
IN EQUIPMENT SCHEDULE
DUCT TRANSITION FROM RECTANGULAR TO ROUND
DUCT TRANSITION
INDICATES A 24"x12" RECTANGULAR DUCT (WIDTH x DEPTH)
INDICATES A 12" ROUND DUCT
INDICATES A 24"x12" FLAT OVAL DUCT (WIDTH x DEPTH)
DOWN DIRECTION PITCH
DIRECTION OF FLOW
DEMO
EXISTING
DETAIL NUMBER LOCATION
SECTION LETTER LOCATION A1
A1
SCALE
SECTION
A. THE DEMOLITION DRAWINGS REFLECT INFORMATION ON EXISTING BUILDING
SERVICES GATHERED BY SITE INSPECTION, DISCUSSIONS WITH MAINTENANCE
PERSONNEL AND PREVIOUS CONSTRUCTION DRAWINGS. THE EXACT LOCATION,
ARRANGEMENT, AND SIZES OF PIPE LINES AND DUCTWORK IN THE EXISTING BUILDING
MAY BE DIFFERENT FROM THAT SHOWN ON THESE DRAWINGS.
SCALE
DETAIL
B. THE CONTRACTOR SHALL COORDINATE THE SHUTDOWN OF EXISTING BUILDING
SERVICES FOR REMOVAL WITH OWNER AUTHORIZED REPRESENTATIVE AND SHALL
CONFORM TO THEIR REQUIREMENTS.
C. DISRUPTION OF NORMAL FACILITY ACTIVITIES ARE TO BE KEPT TO AN ABSOLUTE
MINIMUM. DUST, DEBRIS, AND FUMES SHALL BE CONTROLLED SO AS NOT TO AFFECT
THE HEALTH AND SAFETY OF OCCUPIED AREAS WITHIN THE FACILITY WHICH ARE
OUTSIDE THE AREA OF WORK. COORDINATE WITH THE ARCHITECT AND THE
OWNER'S REPRESENTATIVE WITH REGARD TO ALL ACTIVITIES TO BE CONDUCTED
OUTSIDE OF THE SUITE REMODEL AREA WHICH MAY AFFECT THE OPERATION OF THE
FACILITY.
D. THE CONTRACTOR SHALL PROVIDE TEMPORARY VENTILATION (MAINTAIN WORK ZONE
AT NEGATIVE PRESSURE), FILTRATION, AIR PURIFIERS, DUST SCREENS, ETC. FOR ALL
WORK AREAS AFFECTED BY DEMOLITION FOR NEW INSTALLATION TO MINIMIZE DUST
AND FUMES.
E. THE CONTRACTOR SHALL PRESENT AN AREA BY AREA WORK PLAN WELL IN ADVANCE
TO THE ARCHITECT AND THE OWNER'S AUTHORIZED REPRESENTATIVE FOR
APPROVAL PRIOR TO BEGINNING WORK. THE WORK PLAN SHALL INCLUDE AN
OUTLINE OF ALL ACTIVITIES OF ALL SUBCONTRACTORS. THE CONTRACTOR SHALL
COORDINATE WITH THE OWNER'S AUTHORIZED REPRESENTATIVE TO ESTABLISH
ACCEPTABLE ROUTING AND ACCESS WITHIN THE FACILITY FOR MATERIALS REQUIRED
FOR THE NEW INSTALLATION.
SIDEWALL EXHAUST OR RETURN AIR GRILLE
OR REGISTER
CEILING RETURN AIR REGISTER OR GRILLE
CEILING EXHAUST REGISTER
ENTERING
EXHAUST
ENERGY MANAGEMENT CONTROL SYSTEM
DEGREES FAHRENHEIT
FLAT BOTTOM
FLOOR DRAIN
FAN COIL UNIT
FILTER GAUGE
FLEXIBLE
FEET PER MINUTE
FLOOR SINK
FEET
FLAT TOP
GALLONS PER MINUTE
GALLONS PER HOUR
HOSE BIBB
HIGH EFFICIENCY PARTICULATE AIR (FILTER)
HAND DAMPER (VOLUME DAMPER)
INCHES
INDOOR UNIT
KILOWATT
MAIN AIR (CONTROLS)
KILOWATT HOUR
MOTOR CONTROL CENTER
NUMBER (QUANTITY)
NOT IN CONTRACT
NOT APPLICABLE
OPPOSED BLADE DAMPER
OUTSIDE AIR
PRESSURE REDUCING VALVE
POUNDS PER SQUARE INCH GAGE
PERFORATED FACE CEILING DIFFUSERS
HWS
HWR
CHS
CHR
STAMPED FACE CEILING DIFFUSERS
V
D
CD
MU
RS
RL
R
TWS
TWR
TWB
MPS
HPS
LPS
HPR
HPR
LPR
CND
PC
GWS
GWR
HEATING WATER RETURN
HEATING WATER SUPPLY
CHILLED WATER SUPPLY
CHILLED WATER RETURN
DRAIN
CONDENSATE DRAIN
MAKE-UP WATER
VENT
REFRIGERATION LIQUID
REFRIGERATION SUCTION
REFRIGERATION
TOWER WATER BYPASS
TOWER WATER RETURN
TOWER WATER RETURN
STEAM - HIGH PRESSURE SUPPLY
STEAM - HIGH PRESSURE RETURN
STEAM - MEDIUM PRESSURE SUPPLY
STEAM - LOW PRESSURE SUPPLY
CONDENSER WATER
PUMPED CONDENSATE
GEOTHERMAL SUPPLY
GEOTHERMAL RETURN
SECTION AND DETAIL TITLES
STEAM - MEDIUM PRESSURE RETURN
STEAM - LOW PRESSURE RETURN
DRAWING NUMBER WHERE DETAILED
SECTION LOCATION
DETAIL SYMBOL
DETAIL LOCATION
DRAWING NUMBER WHERE DETAILED
X#/X###
M301 A1
SECTION SYMBOL
B
M
RETURN DUCT
PIPING SYMBOLS
EXHAUST DUCT
MECHANICAL PIPING
SUPPLY DUCT
EXISTING DUCT TO BE REMOVED
FLEXIBLE CONNECTION
RISE IN DUCT
VANED ELBOW (PROVIDE ALL SQUARE OR
RECTANGULAR ELBOWS WITH VANES
EXCEPT TRANSFER AIR SOUND ELBOW)
SHORT RADIUS ELBOW (PROVIDE ALL
SQUARE OR RECTANGULAR ELBOWS WITH
VANES EXCEPT TRANSFER AIR SOUND
ELBOW)
STANDARD LONG RADIUS ELBOW
3/4" BALL VALVE WITH ADAPTER
TO 3/4" HOSE THREAD
DIAPHRAGM VALVE
BUTTERFLY VALVE
BALL VALVE
VALVE IN RISE
WATER FLOW MEASURING DEVICE
CIRCUIT SETTER
F
S
SOLENOID VALVE
POINT OF CONNECTION, NEW DUCT TO EXISTING DUCT
OR / POINT OF REMOVAL FROM EXISTING DUCT TO DEMO DUCT
AIR CONDITIONING UNIT
ABOVE FINISHED FLOOR
ACCESS DOOR
AIR HANDLING UNIT
ACOUSTIC LINING
BRAKE HORSEPOWER
BOTTOM OF DUCT
BOTTOM OF PIPE
BTU PER HOUR
BRITISH THERMAL UNIT
COMPRESSED AIR
CUBIC FEET PER MINUTE
CONDENSATE DRAIN
CONTINUATION
CONTRACTING OFFICER'S REPRESENTATIVE
CONDENSING UNIT
DRAIN
DIRECT EXPANSION
S.DPR
F.DPR
F/S DPR
COMBINATION FIRE/SMOKE DAMPER
PRESSURE REDUCING VALVE
2HR. SMOKE BARRIER
SMOKE BARRIER
2HR. FIRE BARRIER
1 HR. FIRE BARRIER
M
VERIFY WITH
ARCHITECTURAL
DRAWINGS
M
3-WAY
MODULATING
CONTROL VALVE
A
2-WAY CONTROL VALVE
SAFETY VALVE OR
PRESSURE RELIEF
VALVE
P
PS PS
GAUGE - DIFFERENTIAL
GAUGE - PRESSURE
GAUGE - PRESSURE WITH COCK
GAUGE - TEMPERATURE
HS
PS
TS
PIPE ANCHOR
PIPE EXPANSION JOINT
PIPE GUIDE
SENSOR - FLOW
SWITCH - FLOW
SWITCH HUMIDITY
SWITCH - PRESSURE
SWITCH - TEMPERATURE
TEMPERATURE - PRESSURE TEST FITTING
THERMOMETER
THERMOMETER WELL
BASKET STRAINER
STEAM TRAP INVERTED BUCKET
METER - TOTALIZING BTU
METER - TOTALIZING FLOW
AIR VENT - AUTOMATIC
AIR VENT - MANUAL
G. REFER TO THE ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF ALL FIRE
RATED AND/OR SMOKE RATED WALLS AND ASSEMBLIES. PROVIDE APPROVED
FIRE DAMPERS IN ALL REQUIRED PENETRATIONS FOR DUCTWORK, GRILLES,
REGISTERS AND DIFFUSERS. ALL PIPE AND DUCTWORK PENETRATIONS OF FIRE,
SMOKE AND FULL HEIGHT WALLS SHALL BE CAULKED AIRTIGHT TO THE ADJACENT
STRUCTURE BY MEANS OF U.L. APPROVED FIRE PROOF CAULKING MATERIAL.
H. CONTRACTOR SHALL COORDINATE ALL DUCTWORK, PIPING, PLUMBING AND
FIRE PROTECTION PIPING WITH STRUCTURAL AND ELECTRICAL SYSTEMS AND
SHALL PROVIDE NECESSARY OFFSETS TO AVOID CONFLICTS AND TO MAINTAIN
EQUIPMENT ACCESS AND SERVICEABILITY.
I. CONTRACTOR SHALL FURNISH ALL NECESSARY STRUCTURES, INSERTS,
SLEEVES, AND HANGING DEVICES FOR INSTALLATION OF MECHANICAL AND
PLUMBING EQUIPMENT, DUCTWORK AND PIPING, ETC. CONTRACTOR SHALL
COORDINATE WITH GENERAL CONTRACTOR AND ALL BUILDING TRADES TO AVOID
CONFLICTS AND TO MAINTAIN EQUIPMENT ACCESS AND SERVICEABILITY.
J. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL NECESSARY
MISCELLANEOUS ANGLES, CHANNELS, UNISTRUT, ETC., AS MAY BE REQUIRED TO
ADEQUATELY SUPPORT THE MECHANICAL PIPING, DUCTWORK, AND EQUIPMENT
IN A MANNER APPROVED BY THE ARCHITECT, WHICH WILL NOT OVERLOAD THE
BUILDING STRUCTURAL SYSTEM.
K. CONTRACTOR SHALL PROVIDE RETURN AIR OR TRANSFER AIR OPENINGS IN
FULL HEIGHT WALLS SIZED AT 350 FPM (UNLESS OTHERWISE SPECIFICALLY
SHOWN ON THE DRAWINGS) TO CREATE AND/OR MAINTAIN A RETURN AIR PATH AS
REQUIRED. FIRE DAMPERS AND/OR SMOKE DAMPERS SHALL BE PROVIDED IN
SUCH OPENINGS WHERE REQUIRED BY NOTE "J".
L. SEAL ALL TRANSVERSE JOINTS, LONGITUDINAL SEAMS, DUCT WALL
PENETRATIONS AND FITTING CONNECTIONS ON ALL DUCT SYSTEMS.
M. MECHANICAL ITEMS SUCH AS ROOF DRAINS, FLOOR DRAINS, PLUMBING FIXTURES,
ETC. SHOWN ON THE ARCHITECTURAL DRAWINGS BUT NOT SHOWN ON THE
MECHANICAL DRAWINGS SHALL BE INCLUDED IN THE PROJECT. THESE ITEMS
SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT FOR INCLUSION IN
ADDENDUM.
N. IT IS CRITICAL THAT THE CONTRACTOR PERFORM A COMPLETE REVIEW OF ALL
SUBMITTALS PRIOR TO SUBMISSION TO THE AE/COR. INCOMPLETE, INCORRECT
AND UNCLEAR SUBMITTALS WILL BE REJECTS AND MARKED AS "REVISE AND
RESUBMIT". ALL SUBMITTALS MUST CLEARLY INDICATE THE EQUIPMENT
SELECTIONS FOR THE PROJECT. TECHNICAL DRAWINGS OF COMPLETE
ASSEMBLIES, REFLECTING ACCURATE PROJECT CONDITIONS, SHALL BE
SUBMITTED WITH EQUIPMENT SELECTIONS TO ENSURE SPACE ALLOWANCES ARE
REFLECTED IN THE ACTUAL SPACE AVAILABLE. WHERE SIZE DEVIATIONS DIFFER
FROM THE BASIS OF DESIGN CONTRACTOR SHALL HIGHLIGHT THE DIFFERENCES
FOR AE/COR REVIEW WITHIN THE SUBMITTAL. CONTRACTOR SHALL PROVIDE
INSTALLATION ROUTE AND VERIFICATION THAT ACCESS POINTS, PLACEMENT
ROUTE, SUPPORTS, AND REQUIRED EQUIPMENT CLEARANCES ARE IDENTIFIED ON
THE ROUTE DRAWING. SAFETY PROTOCOLS FOR SUBJECT STATION SHALL BE
REFLECTED ON EQUIPMENT CLEARANCES. PLATFORMS AND INTERFACE AREAS
(FILTER, GAUGES, MONITORS, VALVES, ETC.) SHALL HAVE PROPER CLEARANCE AS
DEFINED BY THE MANUFACTURER, VA SAFETY PERSONNEL AND SERVICE
PERSONNEL. ACCESS POINTS OF USE SHALL BE CLEARLY IDENTIFIED ON THE
DRAWINGS.
GENERAL DEMO NOTES
PIPE REDUCER - ECCENTRIC
PIPE STRAINER
UNION - SCREWED
FIRE DAMPER
SMOKE DAMPER
CHECK VALVE
PLUG VALVE
ACOUSTICAL DUCT LINING
FLEXIBLE DUCT
MANUAL BALANCING DAMPER
GATE VALVE
MECHANICAL SYMBOL LEGEND
VALVE SYMBOLS
GLOBE VALVE
ELBOW - DROP TO TEE
TEE - DROP FROM TEE
END CAP
FLEX CONNECTION
PIPE REDUCER - CONCENTRIC
GENERAL NOTES
FITTING SYMBOLS
ELBOW - DOWN
ELBOW - UP
PIPE RISE-DROP
A. ALL PIPING AND DUCTS IN FINISHED ROOMS OR SPACES SHALL BE CONCEALED IN
FURRED CHASES OR SUSPENDED CEILINGS, UNLESS OTHERWISE NOTED.
B. PROVIDE ACCESS PANELS OR DOORS IN INACCESSIBLE CEILINGS AND/OR
CHASES FOR ALL VALVES, TRAPS, DAMPERS, CLEANOUTS, COILS, FANS,
CONTROLS, ETC. THEY SHALL BE FURNISHED UNDER DIVISION 23 AND
INSTALLED UNDER THE ARCHITECTURAL SPECIFICATION. ACCESS DOOR RATING
SHALL MATCH CLASSIFICATION OF WALL AND CEILING FIRE RATING.
C. COORDINATE THE LOCATION OF ALL DIFFUSERS, GRILLES, REGISTERS, ACCESS
DOORS, ETC., WITH THE ARCHITECTURAL REFLECTED CEILING PLAN(S).
D. ALL ROUND RUNOUTS AND DROPS TO DIFFUSERS SHALL BE THE SAME NOMINAL
SIZE AS THE SCHEDULED DIFFUSER NECK SIZE.
E. THE FIRST FIGURE OF DUCT SIZE INDICATES DIMENSION OF FACE SHOWN OR
INDICATED. ALL DUCT SIZES SHOWN ON DRAWINGS ARE NET INSIDE DIMENSIONS.
PROVIDE ONE INCH ACOUSTICAL LINING (TYPE D3 INSULATION) IN LOW VELOCITY
RECTANGULAR DUCTWORK FOR THE FIRST 10 DIAMETERS OF DUCTWORK
CONNECTED TO DEVICE, OR AS INDICATED ON DRAWINGS, WHICHEVER IS
GREATER. FOR THE REMAINDER OF THIS DUCTWORK PROVIDE AS INDICATED IN
THE INSULATION SPECIFICATIONS.
F. PROVIDE 1/2" MANUAL AIR VENTS AT ALL HIGH POINTS OF CLOSED SYSTEM PIPING
AND 1/2" MANUAL DRAIN VALVES WITH HOSE CONNECTION AT LOW POINTS AS
REQUIRED TO PROVIDE COMPLETE SYSTEM DRAINAGE. WHERE DRAIN VALVES
OCCUR ABOVE CEILING AREAS AND IN AREAS OUTSIDE MECHANICAL RANGE
PROVIDE HOSE CONNECTION ON VALVE.
ELECTRICAL DISCONNECT
M-001
MECHANICAL SYMBOLS &
ABBREVIATIONS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
BID DOCUMENTS
N/A
National Cemetery Administration
Design and Construction Service
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
FORT SILL
GRAVESITE EXPANSION AND
CEMETERY FCA IMPROVEMENTS
Elgin, OK
920CM3006
N/A
07/01/2026Revisions: Date: JV
Approved: Project Manager/COR Department of Veteran Affairs, NCA POC: Homayoun Kazemipour Email: homayoun.kazemipour@va.gov
720.491.7559; Sean Fitzpatrick
56 LOUIS PRIMA DRIVE, SUITE B, COVINGTON, LA 70433 JB
JD Engineering, PC 371 Zimmerman Lane Hamilton, MT 59840 Phone: (406) 218 - 9980
07/01/26
AutoCAD SHX Text 40536
AutoCAD SHX Text C
AutoCAD SHX Text O
AutoCAD SHX Text L
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text A
AutoCAD SHX Text D
AutoCAD SHX Text O
AutoCAD SHX Text L
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text B
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text D
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text M
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text C
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text L
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text P
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text E
R
1 2
CU-01
IU-01
REFRIGERANT LINE SET
1. DEMOLISH SINK AND REFRIGERATOR ICE MAKER BOX
2. REMOVE AND CAP ALL CONNECTED WATER PIPING BEHIND DRYWALL VENT
AND SANITARY PIPING SHALL REMAIN TO BE CONNECTED TO CONDENSATE
DRAIN. REMOVE HW/CW LINES BACK TO BRANCH LINE VALVE IN CEILING
SPACE.
DEMO KEYED NOTES:
3. EXISTING DUCTWORK SHALL REMAIN, CEILING DIFFUSERS SHALL BE
REMOVED CLEANED AND REINSTALLED IN NEW CEILING LAYOUT.
1. INSTALL NEW WALL MOUNTED AC UNIT AS SHOWN.
2. CONNECT 1" CONDENSATE DRAIN LINE TO EXISTING DRAIN FROM REMOVED
SINK, PROVIDE 1-1/2" AIR GAP DRAIN FITTING WITH TRAP.
KEYED NOTES:
3. INSTALL NEW 4" CONCRETE PAD FOR OUTDOOR UNIT(CU-1)
4. INSTALL NEW OUTDOOR UNIT (CU-1) ON CONCRETE PAD, COORDINATE
WITH EXISTING UNITS FOR PROPER SERVICE CLEARANCES.
M-101
ADMIN-TELECOM DEMO/NEW WORK
HVAC/PLUMBING PLAN
0 2 4
4" = 1' 0"
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
BID DOCUMENTS
N/A
National Cemetery Administration
Design and Construction Service
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
FORT SILL
GRAVESITE EXPANSION AND
CEMETERY FCA IMPROVEMENTS
Elgin, OK
920CM3006
N/A
07/01/2026Revisions: Date: JV
Approved: Project Manager/COR Department of Veteran Affairs, NCA POC: Homayoun Kazemipour Email: homayoun.kazemipour@va.gov
720.491.7559; Sean Fitzpatrick
56 LOUIS PRIMA DRIVE, SUITE B, COVINGTON, LA 70433 JB
JD Engineering, PC 371 Zimmerman Lane Hamilton, MT 59840 Phone: (406) 218 - 9980
07/01/26
AutoCAD SHX Text
SCALE: 1/4"=1'-0"
AutoCAD SHX Text
ADMIN-TELECOM CLOSET DEMO PLAN
AutoCAD SHX Text D1
AutoCAD SHX Text
SCALE: 1/4"=1'-0"
AutoCAD SHX Text
ADMIN-TELECOM CLOSET NEW WORK PLAN
AutoCAD SHX Text D4
AutoCAD SHX Text 40536
A…