RFP_1100_MMH3038_ATT_7_v1.pdf

PDF 81 KB Posted

Attached to
Gas Turbine 7FA & Steam Turbine D-11- Parts, Maintenance, Se
Solicitation number
RFP 1100 MMH3038
Issued by
Texas

About this file

This is Attachment 7 to a Request for Proposals (RFP 1100 MMH3038) for Austin Energy's Sand Hill Energy Center Unit 5 Combined Cycle plant, establishing field and shop service labor rates for planned, corrective, predictive, and preventative maintenance, as well as minor upgrades on a Gas Turbine 7FA and Steam Turbine D-11 system located in Texas. The attachment provides a comprehensive labor rate schedule that contractors must propose for various specialist and technical positions, including engineers, field engineers, specialty field engineers, startup specialists, onsite project managers, and multiple categories of specialists such as generator specialists, gas turbine specialists, vibration specialists, laser alignment specialists, and repair specialists for both gas and steam turbine systems. Additional labor categories include craft supervision, work leaders, automated machining repair specialists, quality inspectors across mechanical, electrical, and instrumentation disciplines, safety supervisors, and safety technicians, with the schedule requiring bidders to provide both standard hourly rates and overtime hourly rates for each position.

Bidders are required to submit labor rate proposals for all listed personnel categories and must attach supplementary lists with similar rate information for any additional personnel categories anticipated during the contract period. The attachment explicitly requires contractors to provide a policy governing the application of overtime rates, including any limitations on weekly overtime scheduling. This labor rate schedule serves as a critical pricing component of the RFP, enabling Austin Energy to evaluate total cost of ownership for the maintenance contract based on the anticipated labor requirements and staffing levels necessary to support ongoing operations and maintenance activities at the Sand Hill Energy Center.

View the file

Other files

File Type Posted
RFP_1100_MMH3038_PAC1_v1.docx DOCX document
RFP_1100_MMH3038_PLANS_1_v1.pdf PDF
RFP_1100_MMH3038_MWDBE_PAC_v1.pdf PDF
IFB_9000_AAM1014REBID_PAC1_v1.pdf PDF
RFP_1100_MMH3038_ATT_1_v1.pdf PDF
RFP_1100_MMH3038_BID_DOC_v1.xls XLS spreadsheet
RFP_1100_MMH3038_ATT_5_v1.pdf PDF
RFP_1100_MMH3038_ATT_4_v1.pdf PDF
RFP_1100_MMH3038_PAC2_v1.pdf PDF
RFP_1100_MMH3038_ATT_3_v1.pdf PDF
RFP_1100_MMH3038_0500_v1.docx DOCX document
RFP_1100_MMH3038_ATT_2_v1.pdf PDF
RFP_1100_MMH3038_ATT_6_v1.pdf PDF
RFP_1100_MMH3038_0600_v1.pdf PDF
Show all 14

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ATTACHMENT 7

Field/Shop Service Labor Rates

Service Description Standard Hourly Rate Overtime Hourly Rate

Engineer/Field Engineer

Specialty Field Engineer

Startup Specialist

Onsite Project Manager

Offsite Project Scheduler

Generator Specialist

Static Starter Specialist

(LCI)

Gas/Steam Path Audit Specialist

Gas Turbine DLN Specialist

Vibration (Balance)

Laser Alignment Specialist

Consulting Analyst

Diagnostics

Generator Winder

Controls Specialist

Millwright

Craft Supervision

Work Leader

Automated Machining

Repair Specialist

Gas Turbine Onsite Repair

Gas Turbine Shop Repair

Steam Onsite Repair

Steam Shop Repair

Service Description Standard Hourly Rate Overtime Hourly Rate

Safety Supervisor

Safety Technician/Specialist

Quality Inspector – Mechanical and Piping

Quality Inspector - Electrical

Quality Inspector – Instrument and Controls

Notes: 1. Attach list with similar information for any other personnel categories that may be used during the contract period.

2. Provide policy governing the application of overtime rates, including any limits on weekly schedule of overtime.

File details come from the government source that posted it. Updated .