(x)
R14PS00485
x x
7 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted ; or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGEMENT TO BE RECEIVED AT
THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted , such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
x
Boise ID 83706-1234 1150 N. Curtis Road, Ste. 100
R10
Acquisition Management Division Regional Office Pacific Northwest Region Bureau of Reclamation
12/22/2014000005
13. THIS ITEM ONLY APPLIES TO MODIFICATION OF CONTRACTS/ORDERS. IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
12. ACCOUNTING AND APPROPRIATION DATA (If required) is not extended.is extended, Items 8 and 15, and returning
Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended , by one of the following methods: (a) By completing
The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
FACILITY CODE CODE
10B. DATED (SEE ITEM 13)
10A. MODIFICATION OF CONTRACT/ORDER NO.
9B. DATED (SEE ITEM 11)
9A. AMENDMENT OF SOLICITATION NO.
CODE
8. NAME AND ADDRESS OF CONTRACTOR (No., street, county, State and ZIP Code)
7. ADMINISTERED BY (If other than Item 6)CODE 6. ISSUED BY
PAGE OF PAGES
4. REQUISITION/PURCHASE REQ. NO.3. EFFECTIVE DATE2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO. (If applicable)
1. CONTRACT ID CODE
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
11/04/2014
CHECK ONE A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority) appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).
E. IMPORTANT: Contractor is not, is required to sign this document and return __________________ copies to the issuing office.
ORDER NO. IN ITEM 10A.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
A. Project Title: Allen E. Inman Powerplant Unit 8 and Unit 9 Turbine Overhaul, Minidoka
Project, Idaho
B. The time and date for receipt of offers remains at 2:00 pm, Mountain Time, January 22, 2015.
C. Acknowledgment: See block 11 above regarding how to acknowledge this amendment. The acknowledgment must be received at the place designated for receipt of offers (see block 8 of "Solicitation, Offer and Award" Standard Form 1442). ALL AMENDMENTS MUST BE
ACKNOWLEDGED. However, offerors are notified that acknowledgement of either amendment 0002 or 00003 is acceptable (offerors need only acknowledge one or the other of these 2
Continued ...
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)15A. NAME AND TITLE OF SIGNER (Type or print)
15C. DATE SIGNED 16B. UNITED STATES OF AMERICA 15B. CONTRACTOR/OFFEROR 16C. DATE SIGNED
(Signature of person authorized to sign) (Signature of Contracting Officer)
Rebecca L. Thomson
STANDARD FORM 30 (REV. 10-83)
Prescribed by GSA
FAR (48 CFR) 53.243
NSN 7540-01-152-8070
Previous edition unusable
Except as provided herein, all terms and conditions of the document referenced in Item 9 A or 10A, as heretofore changed, remains unchanged and in full force and effect .
ITEM NO. SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT
NAME OF OFFEROR OR CONTRACTOR
2 2
CONTINUATION SHEET
REFERENCE NO. OF DOCUMENT BEING CONTINUED PAGE OF
(A) (B) (C) (D) (E) (F)
R14PS00485/000005
amendments and not both).
--- see continuation pages ---
NSN 7540-01-152-8067 OPTIONAL FORM 336 (4-86)
Sponsored by GSA
FAR (48 CFR) 53.110
Solicitation R14PS00485 Allen E. Inman Powerplant Unit 8 and Unit 9 Turbine Overhaul
Amendment 005
D. Offer Modification: See block 11 above if you have submitted your offer and now desire to modify or withdraw it.
E. Third Party: If you have given your copy of the solicitation to someone else, please forward this amendment accordingly.
F. NOTE: The following changes are hereby incorporated into the solicitation. Single-sided replacement pages are provided following this Standard Form 30 and changes are shown with left side bar or shaded. Offerors who’ve prepared 2-sided copies of the solicitation may wish to attach the one-sided revised pages to the original version in order to preserve the reverse side of the original page.
G. In Section C, Description/Specifications/Statement of Work, the following pages are deleted and the attached revised pages are substituted therefore:
Remove Pages Insert Revised Pages 48 13 31-6 and 48 13 31-7 48 13 31-6 and 48 13 31-7 48 13 31-9 48 13 31-9 Add Pages 51 10 00-13 thru 51 10 00-17 (Photographs) 52 00 00-3 52 00 00-16
In Drawings the following drawing has been added.
Remove Drawing Insert Drawing None 59b 17-D-2201
Attachments
Solicitation No.R14PS00485
Amendment No. 005
Revised 48 13 31 - 6
v. Red running indicating light.
vi. One Normally Open and One Normally Closed contactor auxiliary contact.
vii. Located in a NEMA 4 enclosure mounted on or near the pumping units.
e) Duplex filter with directional valve.
7) Drain and filling connections:
a) Filling connection shall have a valve controlling the inflow located within the cabinet and discharge above the oil level.
b) Drain connection at bottom of sump, 2-inch lockable valve.
8) Heaters:
a) Ambient temperature around the Governor and powerplant could be as low as 32 degrees Fahrenheit (0 degrees Celsius).
b) Provide heaters to prevent condensation forming and water mixing with the oil.
c) Size and locate heaters to keep homogenous oil temperature.
d) Immersion type heaters.
e) Suitable to operate on a 480-volt nominal circuit.
f) A thermostat and a combination magnetic starter with unfused disconnect switch shall be provided to control heaters.
i. 120-volt control starter.
ii. 480/120-volt transformer with one secondary fuse shall be provided in the starter enclosure.
iii. Equip starter with overload elements in all three phases.
iv. Located in a NEMA 4 enclosure mounted on or near the pumping units.
g) Add an adjustable temperature switch to monitor the oil temperature and provide a high temperature alarm and shutdown to the unit control system.
c. Equip breather connection on oil sump with a metallic-type oil vapor filter.
31. Oil Pumps:
a. Pump requirements:
1) Provide two duplicate motor-driven oil pumps.
2) DELETED
48 13 31 - 7
3) Capacity not less than 3 gallons per minute at the system design pressure.
4) Suction lift of not less than 5 feet.
5) Each pump shall be self-priming.
6) Provide each pump with an unloader valve, check valve, relief valve, and a suitable number of hand-operated valves so arranged as to constitute a complete unit with minimum number of flanges or screwed connections.
7)_ Arrange pump connections so either pump may be disconnected and removed without interfering with the continuous operation of the other pump or oil system.
b. Motor requirements:
1) Conform to NEMA MG1, including characteristics tests and ratings unless otherwise specified.
2) One motor for each pump.
3) Premium efficiency, squirrel-cage induction type.
4) Direct connected and rated 460 volts, 3-phase, 60 cycles.
5) Coordinate with the pump to match the characteristic requirements, and torque requirements to provide proper operation of the unit during sequence starting, acceleration, and normal running.
6) Indoor service, totally enclosed fan cooled (TEFC) drip-proof type enclosure.
7) Stainless steel nameplate with data in accordance with NEMA
MG-1.
8) Provide sufficient access for work space and maintenance.
9) Each motor shall be suitable for across-the-line starting, with the current kept as low as practicable consistent with good design.
10) Horsepower rating shall be such that it will carry continuously the maximum load possible to develop under all pumping conditions.
a) Shall not exceed nameplate rating.
b) Without benefit of the service factor.
11) Self-cooled motor by means of fan blades or other methods on the rotor.
12) Winding insulation:
a) Class F.
b) Moisture tight.
c) Mechanically stable.
d) Abrasive resistant.
e) Sufficiently resilient to comply with standard.
48 13 31 - 9
g) Motor control circuits:
i. Completely wired and interconnected with pump motor.
ii. Motor starter control circuit: 120-volt, 60-hertz.
iii. Include a 480/120-volt, 60-hertz single phase control transformer with one secondary fused and the other grounded, and located in each starter enclosure.
iv. Hand-Off-Automatic control switch on enclosure door and clearly maked with nameplates.
v. Provide indicating lamps on the enclosure:
vi. Red - closed position of the motor starter (RUN).
vii. Amber – overload fault.
viii. 120V, push to test, LED type.
ix. Provide two normally open and two normally closed starter auxillary contacts wired to terminal blocks.
x. Connect one NO contact to governor control to monitor status and run time.
xi. Provide suitable terminal blocks with moisture-proof markings strips in an accessible place in the enclosure for control wiring.
d. Controls:
1) Automatic controls which will start and stop the pumps at the predetermined oil pressure values, measured at the discharge of the governor oil pumps. (controls required if new digital governor does not include control system for the governor oil pumps.)
2) Provide control switch to select between lead and lag pumps.
3) Designed so that lead pump motor runs continuously and lag pump motor cycles on and off as needed to maintain system pressure.
4) Arrange starting equipment to start the motors and permit them to reach full speed before pump loads and to unload the pumps before the motors are disconnected from the power supply.
5) Enclosure:
i. NEMA 4.
ii. Pad-lockable with hinged door.
iii. Vapor proof seals for cable entries.
iv. Mounted on or near the pumping units.
51 10 00 - 13
51 10 00 - 14
51 10 00 - 15
51 10 00 - 16
51 10 00 - 17
PART 2 PRODUCTS
Not Used
PART 3 EXECUTION
Not Used
END OF SECTION
Amendment No. 005
52 00 00 - 3
Table 52 00 00A - List of Drawings
Sheet No.
Drawing No. Title Manufacturer’s Drawing No.
Maps and Plans – General:
1 17-107-2000 Location Map N/A
2 17-D-2189 Location Plan N/A
3 17-D-2687 Minidoka Powerplants, Switchyards, and Substation – Power and Control Cable Routing for Radial Gates – Area Plan
N/A
4 17-D-2201 Minidoka Replacement Powerplant – General Arrangement – Floor – El. 4189.25 and 4174.38
N/A
5 17-D-2202 Minidoka Replacement Powerplant – General Arrangement – Longitudinal Section Thru CL Unit 9
N/A
Information Drawings (Allen E. Inman Powerplant – Electrical Installation):
6 17-D-2039 Units 8 and 9 – Main Single Line Diagram N/A
7 17-D-2726 Unit 8 Controls – 125 VDC Circuits – Schematic Diagram – Sheet 1 of 3
N/A
8 17-D-2727 Unit 8 Controls – 125 VDC Circuits – Schematic Diagram – Sheet 2 of 3
N/A
9 17-D-2728 Unit 8 Controls – 125 VDC Circuits – Schematic Diagram – Sheet 3 of 3
N/A
10 17-D-2729 Unit 8 Protection – 125 VDC Circuits – Schematic Diagram – Sheet 1 of 2
N/A
11 17-D-2730 Unit 8 Protection – 125 VDC Circuits – Schematic Diagram – Sheet 2 of 2
N/A
12 17-D-2731 Unit 8 – Generator Differential Protection – 125 VDC Circuits – Schematic Diagram
N/A
13 17-D-2736 Unit 8 Breaker Control – 125 VDC Circuits – Schematic Diagram
N/A
14 17-D-2737 Unite 8 Annunciator – 125 VDC Circuits – Schematic Diagram – Sheet 1 of 2
N/A
15 17-D-2738 Unit 8 Annunciator – 125 VDC Circuits – Schematic Diagram – Sheet 2 of 2
N/A
Amendment No. 005
Revised 52 00 00 - 4
Table 52 00 00A - List of Drawings
Sheet No.
Drawing No. Title Manufacturer’s Drawing No.
16 17-D-2739 Unit 9 Controls – 125 VDC Circuits – Schematic Diagram – Sheet 1 of 3
N/A
17 17-D-2740 Unit 9 Governor Controls – 125 VDC Circuits
– Schematic Diagram – Sheet 2 of 3
N/A
18 17-D-2741 Unit 9 Governor Controls – 125 VDC Circuits
– Schematic Diagram – Sheet 3 of 3
N/A
19 17-D-2742 Unit 9 Protection – 125 VDC Circuits – Schematic Diagram – Sheet 1 of 2
N/A
20 17-D-2743 Unit 9 Protection – 125 VDC Circuits – Schematic Diagram – Sheet 2 of 2
N/A
21 17-D-2744 Unit 9 – Generator Differential Protection – 125 VDC Circuits – Schematic Diagram
N/A
22 17-D-2750 Unit 9 Annunciator – 125 VDC Circuits – Schematic Diagram – Sheet 1 of 2
N/A
23 17-D-2751 Unit 9 Annunciator – 125 VDC Circuits – Schematic Diagram – Sheet 2 of 2
N/A
24 17-D-2753 Units 8 and 9 Synchronizing Control – 125 VDC Circuits – Schematic Diagram
N/A
25 17-D-2761 Unit 8 Governor – 24 VDC Circuits – Schematic Diagram – Sheet 1 of 3
N/A
26 17-D-2762 Unit 8 Governor – 24 VDC Circuits – Schematic Diagram – Sheet 2 of 3
N/A
27 17-D-2763 Unit 8 Governor – 24 VDC Circuits – Schematic Diagram – Sheet 3 of 3
N/A
28 17-D-2764 Unit 9 Governor – 24 VDC Circuits – Schematic Diagram – Sheet 1 of 3
N/A
29 17-D-2765 Unit 9 Governor – 24 VDC Circuits – Schematic Diagram – Sheet 2 of 3
N/A
30 17-D-2766 Unit 9 Governor – 24 VDC Circuits – Schematic Diagram – Sheet 3 of 3
N/A
31 17-D-2783 Governor A8A – Right Side Door – DR – Wiring Diagram – Sheet 1 of 9
N/A
32 17-D-2784 Governor A8A – Left Side Door – DL – Wiring Diagram – Sheet 2 of 9
Amendment No. 005
Revised 52 00 00 - 5
Table 52 00 00A - List of Drawings
Sheet No.
Drawing No. Title Manufacturer’s Drawing No.
33 17-D-2785 Governor A8A – Top Back Panel – B – Wiring Diagram – Sheet 3 of 9
34 17-D-2786 Governor A8A – PLC Slots C0 Through C7 – Back Panel – B – Wiring Diagram – Sheet 4 of 9
N/A
35 17-D-2787 Governor A8A – PLC Slots C8 Through C15
– Back Panel – B – Wiring Diagram – Sheet 5 of 9
N/A
36 17-D2788 Governor A8A – Middle Back Panel – B – Wiring Diagram – Sheet 6 of 9
N/A
37 17-D-2789 Governor A8A – Bottom Back Panel – B – Wiring Diagram – Sheet 7 of 9
N/A
38 17-D-2790 Governor A8A – Right Side Terminal Panel – R – Wiring Diagram – Sheet 8 of 9
N/A
39 17-D2791 Governor A8A – Left Side Terminal Panel – L
– Wiring Diagram – Sheet 9 of 9
N/A
40 17-D-2995 Turbine H8 – Terminal Cabinet H8A – Wiring Diagram
N/A
41 17-D-2996 Unit 8 – AC and DC Auxiliaries – Schematic Diagrams – Sheet 1 of 2
N/A
42 17-D-3025 Unit 8 Auxiliaries – Schematic Diagram – Sheet 2 of 2
N/A
43 17-D-2997 Plant Auxiliaries – Schematic Diagrams – Sheet 1 of 3
N/A
44 17-D-2998 Plant Auxiliaries – Schematic Diagrams – Sheet 2 of 3
N/A
45 17-D-2999 Plant Auxiliaries – Schematic Diagrams – Sheet 3 of 3
N/A
46 17-D-3000 Turbine H9 – Terminal Cabinet H9A – Wiring Diagram
N/A
47 17-D-3014 Governor A9A – Right Side Door – DR – Wiring Diagram – Sheet 1 of 9
N/A
48 17-D-3015 Governor A9A – Left Side Door – DL – Wiring Diagram – Sheet 2 of 9
Amendment No. 005
Revised 52 00 00 - 6
Table 52 00 00A - List of Drawings
Sheet No.
Drawing No. Title Manufacturer’s Drawing No.
49 17-D-3016 Governor A9A – Top Back Panel – B – Wiring Diagram – Sheet 3 of 9
N/A
50 17-D-3017 Governor A9A – PLC Slots C0 Through C7 – Back Panel – B – Wiring Diagram – Sheet 4 of 9
N/A
51 17-D-3018 Governor A9A – PLC Slots C8 Though C15 – Back Panel – B – Wiring Diagram – Sheet 5 of 9
N/A
52 17-D-3019 Governor A9A – Middle Back Panel – B – Wiring Diagram – Sheet 6 of 9
N/A
53 17-D-3020 Governor A9A – Bottom Back Panel – B – Wiring Diagram – Sheet 7 of 9
N/A
54 17-D-3021 Governor A9A – Right Side Terminal Panel – R – Wiring Diagram – Sheet 8 of 9
N/A
55 17-D-3022 Governor A9A – Left Side Terminal Panel – L
– Wiring Diagram – Sheet 9 of 9
N/A
56 17-D-3023 Unit 9 – AC and DC Auxiliaries – Schematic Diagrams – Sheet 1 of 2
N/A
57 17-D-3024 Unit 9 Auxiliaries – Schematic Diagrams – Sheet 2 of 2
N/A
58 17-D-3026 Governor Hydraulic Pumping Unit (HPU) – Terminal Cabinet A8B – Wiring Diagram
N/A
59 17-D-3027 Governor Hydraulic Pumping Unit (HPU) – Terminal Cabinet A9B – Wiring Diagram
N/A
59a 17-D-2418 Minidoka Replacement Powerplant - Access Bridge - Plans, Elevations, and Sections
N/A
59b 17-D-2201 Minidoka Replacement Powerplant – General Arrangement – Floor – El. 4189.25 and 4174.38
N/A
Original Manufacture Drawings:
60 17-MD-758-116 Thrust & Guide Bearing_1 2.33-9626_1
61 17-MD-758-117 Thrust & Guide Bearing_2 2.33-9626_2
62 17-MD-758-119 Oil Supply Head (Servomotor) 2.33-9912_1
63 17-MD-758-120 Oil Supply Head (Servomotor) 2.33-9912_2
Amendment No. 005
Revised 52 00 00 - 7
Table 52 00 00A - List of Drawings
Sheet No.
Drawing No. Title Manufacturer’s Drawing No.
64 17-MD-758-122 Shaft Seal Drawing Installation and Removal 2.35-1830
65 17-MD-758-128 Hydrodynamic Shaft Seal 2.35-2477_1
66 17-MD-758-129 Hydrodynamic Shaft Seal 2.35-2477_2
67 17-MD-758-136 Hydrodynamic Shaft Seal 2.35-2662
68 17-MD-758-144 Control Valve w/ Emergency Shut Down 2.41-52853
69 17-MD-758-145 Distributor (2 sheets U8/U9) 2611-0111
70 17-MD-758-146 Kaplan Runner Assembly 2611-0114
71 17-MD-758-147 Runner Assembly Plan (2 sheets) 2611-0115
72 17-MD-758-148 Runner Scale Arrangement 2611-0116
73 17-MD-758-149 Speed Switch Assembly 2611-0119
74 17-MD-758-150 Outer Wicket Gate Bearing Assembly 2611-0120
75 17-MD-758-151 Inner Wicket Gate Bearing Assembly 2611-0121
76 17-MD-758-152 Split Flange Dowel Assembly 2611-0123
77 17-MD-758-153 Disassembly of Taper Pin 2611-0124
78 17-MD-758-154 Position Indicator 2611-0125
79 17-MD-758-155 Self-Reset Link Assembly 2611-0126
80 17-MD-758-156 Mandoor Assembly 2611-0128
81 17-MD-758-157 S-Turbine Distributor Section 2611-0132
82 17-MD-758-158 Turbine Driving Shaft to Generator Shaft 2611-0133
83 17-MD-758-159 Slip Joint Assembly 2611-0134
84 17-MD-758-160 Gate Servomotor Assembly 2611-0136
85 17-MD-758-161 Intermediate Ring Assembly 2611-0137
86 17-MD-758-162 Inlet Casing Piping (Upper) 2611-0143_1
87 17-MD-758-163 Inlet Casing Piping (Lower) 2611-0143_2
88 17-MD-758-164 Lower Inlet Piezometer Piping 2611-0146
Amendment No. 005
Revised 52 00 00 - 8
Table 52 00 00A - List of Drawings
Sheet No.
Drawing No. Title Manufacturer’s Drawing No.
89 17-MD-758-165 Blade Restoring Mechanism Assembly 2611-0147_1
90 17-MD-758-166 Blade Restoring Mechanism Assembly 2611-0147_2
91 17-MD-758-167 Gate Restoring Mechanism 2611-0156
92 17-MD-758-168 Unit 8 Piping Section 2611-0161
93 17-MD-758-169 Unit 8 Piping Upstream Wall Piping 2611-0162
94 17-MD-758-170 Unit 9 Piping Section 2611-0163
95 17-MD-758-171 Unit 9 Piping Upstream Wall Piping 2611-0164
96 17-MD-758-172 Generator Piping Sections 2611-0173
97 17-MD-758-173 Generator Piping Sections 2611-0174
98 17-MD-758-174 Generator Piping Sections 2611-0175
99 17-MD-758-175 Static Head Tank Piping 2611-0176
100 17-MD-758-176 Pit Spanning Piping Sections 2611-0178
101 17-MD-758-177 Generator Air Brake Piping 2611-0179
102 17-MD-758-178 Inlet Casing Lighting 2611-0180
103 17-MD-758-179 Upstream Wall Generator Water Supply 2611-0182
104 17-MD-758-181 Servomotor Baseplate Field Modifications 2611-0184
105 17-MD-758-182 Draft Tube Liner Plan 2612-0596
106 17-MD-758-183 Draft Tube Liner Elevation 2612-0597
107 17-MD-758-184 Draft Tube Liner Sections 2612-0598
108 17-MD-758-185 Blade Condition as from Foundry 2612-0604
109 17-MD-758-186 Inlet Casing 2612-0606
110 17-MD-758-187 Outer Gate Barrel 2612-0612
111 17-MD-758-188 Inner Gate Barrel 2612-0614
112 17-MD-758-189 Wicket Gate 2612-0615
113 17-MD-758-190 Turbine Driving Shaft 2612-0616
Amendment No. 005
Revised 52 00 00 - 9
Table 52 00 00A - List of Drawings
Sheet No.
Drawing No. Title Manufacturer’s Drawing No.
114 17-MD-758-191 Inlet Casing Embedment Stiffener 2612-0624
115 17-MD-758-192 Runner Hub 2612-0625
116 17-MD-758-194 Intermediate Flange 2612-0627
117 17-MD-758-209 Foundation Plan 2612-0656
118 17-MD-758-210 Foundation Elevation 2612-0657
119 17-MD-758-213 Nose Cone 2612-0667
120 17-MD-758-214 Inlet Cone 2612-0669
121 17-MD-758-215 Inlet Cylinder 2612-0670
122 17-MD-758-216 Blade Finish Condition 2612-0671
123 17-MD-758-218 Seal Loading Segment 2612-0682
124 17-MD-758-219 Inner Oil Pipe 2612-0683
125 17-MD-758-220 Outer Oil Pipe 2612-0684
126 17-MD-758-221 Inner Gate Barrel 2612-0686
127 17-MD-758-222 Support Ring 2612-0690
128 17-MD-758-223 Stub Shaft 2612-0697
129 17-MD-758-224 Coupling Bolt (M80 x 6) 2612-0698
130 17-MD-758-228 Discharge Ring 2612-0704
131 17-MD-758-244 Operating Ring 2612-0737
132 17-MD-758-247 Intermediate Ring 2612-0753
133 17-MD-758-248 Draft Tube Liner Ship Outlines 2612-0758
134 17-MD-758-249 Stub Shaft Counterbalance 2612-0760
135 17-MD-758-250 Lift Lug 2612-0761
136 17-MD-758-251 M20 x 1.5 Stud 2612-0763
137 17-MD-758-252 Washer Plate 2612-0764
138 17-MD-758-253 Stud Shaft Support 2612-0765
Amendment No. 005
Revised 52 00 00 - 10
Table 52 00 00A - List of Drawings
Sheet No.
Drawing No. Title Manufacturer’s Drawing No.
139 17-MD-758-254 Retainer Plate 2612-0766
140 17-MD-758-255 Special Washer 2612-0767
141 17-MD-758-256 Turbine Shaft Support 2612-0768
142 17-MD-758-257 Wood Block 2612-0769
143 17-MD-758-258 Hose Clamping Detail 2612-0782
144 17-MD-758-259 Static Head Tank 2612-0787
145 17-MD-758-260 Dowel Pin 2612-0789
146 17-MD-758-261 M80 x 6 Stud 2612-0791
147 17-MD-758-262 Counter Weight 2612-0793
148 17-MD-758-263 Scale (for blade restoring mechanism assembly)
2612-0815
149 17-MD-758-264 Wicket Gate Machining 2612-0831
150 17-MD-758-265 Clevis 2612-0832
151 17-MD-758-266 Pin 2612-0833
152 17-MD-758-267 Pin Retainer 2612-0834
153 17-MD-758-268 Servomotor Base Plate 2612-0835
154 17-MD-758-269 Channel, Pipe Hanger 2612-0836
155 17-MD-758-270 Angle, Pipe Hanger 2612-0837
156 17-MD-758-271 Anchor Plate 2612-0838
157 17-MD-758-272 Angle, Pipe Hanger 2612-0839
158 17-MD-758-273 Angle, Pipe Hanger 2612-0843
159 17-MD-758-274 Bracket Plate 2612-0847
160 17-MD-758-275 Outer Gate Barrel (Unit 2 only) 2612-0856
161 17-MD-758-276 Fitting Ring (for thrust bearing) 2612-0857
162 17-MD-758-277 Seal Assembly Procedure 2613-0042
Amendment No. 005
Revised 52 00 00 - 11
Table 52 00 00A - List of Drawings
Sheet No.
Drawing No. Title Manufacturer’s Drawing No.
163 17-MD-758-278 Runner Blade Clearance at Max Angle 2613-0043
164 17-MD-758-279 Hoist Ring Install & Lifting Spec 2613-0047
165 17-MD-758-280 Turbine Disassembly Figure 1 2613-0051
166 17-MD-758-281 Turbine Disassembly Figure 2 2613-0052
167 17-MD-758-282 Turbine Disassembly Figure 3 2613-0053
168 17-MD-758-283 Turbine Disassembly Figure 4 2613-0054
169 17-MD-758-284 Turbine Disassembly Figure 5 2613-0055
170 17-MD-758-285 Turbine Disassembly Figure 6 2613-0056
171 17-MD-758-286 Turbine Disassembly Figure 7 2613-0057
172 17-MD-758-287 Turbine Disassembly Figure 8 2613-0058
173 17-MD-758-288 Turbine Disassembly Figure 9 2613-0059
174 17-MD-758-289 Turbine Disassembly Figure 10 2613-0060
175 17-MD-758-290 Turbine Disassembly Notes_1 2613-0061_1
117A 17-MD-758-290 Turbine Disassembly Notes_2 2613-0061_2
117B 17-MD-758-290 Turbine Disassembly Notes_3 2613-0061_3
176 17-MD-758-291 Field Setting for Shaft 2613-0062
177 17-MD-758-292 Shaft Alignment Field Check Sheet 2613-0066
178 17-MD-758-293 Turbine Bearing Disassembly Procedure 2613-0067
179 17-MD-758-294 Runner Blade Material, NDE Inspection, and Repair Specification Sheet
2614-0046
180 17-MD-758-295 Round Rubber Cord Specification 2614-0048
181 17-MD-758-297 Inlet Casing and Draft Tube Liner Field Setting Check Sheet
2617-0030
182 17-MD-758-298 Turbine and Generator Shaft Alignment 2617-0038
183 17-MD-758-299 General Arrangement 2618-0156
184 17-MD-758-300 Shafting Arrangement 2619-0141
Amendment No. 005
Revised 52 00 00 - 12
Table 52 00 00A - List of Drawings
Sheet No.
Drawing No. Title Manufacturer’s Drawing No.
185 17-MD-758-301 Foundation Loads 2619-0142
186 17-MD-758-302 Inlet Cylinder Mandoor 2619-0242
187 17-MD-758-303 Wicket Gate Modification 2619-0254
188 17-MD-758-304 Runner Assembly Shipping Sketch 2619-0297
189 17-MD-758-305 Plug (for Inlet Casing Flange) 2622-2944
190 17-MD-758-306 Schematic - Valve Arrangement 2641-0066
191 17-MD-758-307 Schematic - Governor Pumping Unit 2641-0067
192 17-MD-758-308 Schematic - Air Brake System 2641-0072
193 17-MD-758-309 Outline – Governor Enclosure 2642-0260
194 17-MD-758-310 Enclosure Specification – Digital Governor _1
2642-0262_1
195 17-MD-758-311 Enclosure Specification – Digital Governor _2
2642-0262_2
196 17-MD-758-312 Arrangement – Enclosure Front Doors_1 2642-0263_1
197 17-MD-758-313 Arrangement – Enclosure Front Doors_2 2642-0263_2
198 17-MD-758-315 Arrangement – Cubicle Internal Panels 2642-0264
199 17-MD-758-343 PLC Rack – Module Assignments – One Slot Addressing
2642-0267
200 17-MD-758-344 Fuse Chart – Digital Governor 2642-0269
201 17-MD-758-345 Lubrication Schematic 2642-0270
202 17-MD-758-346 Turbine Schematic 2642-0288
203 17-MD-758-347 Elementary Diagram_1 2642-0289_1
204 17-MD-758-348 Elementary Diagram_2 2642-0289_2
205 17-MD-758-349 Elementary Diagram_3 2642-0289_3
206 17-MD-758-350 Connection Diagram_1 2642-0338_1
207 17-MD-758-351 Connection Diagram_2 2642-0338_2
Amendment No. 005
Revised 52 00 00 - 13
Table 52 00 00A - List of Drawings
Sheet No.
Drawing No. Title Manufacturer’s Drawing No.
208 17-MD-758-352 Connection Diagram_3 2642-0338_3
209 17-MD-758-353 Switch Development 2642-0339
210 17-MD-758-354 Grounding Bus Bar – Enclosure 2642-0395
211 17-MD-758-355 Turbine Bearing Casing Conduit 2642-0479
212 17-MD-758-356 Conduit Elevation 2642-0480
213 17-MD-758-357 Conduit Plan 2642-0481
214 17-MD-758-358 Conduit Elevation (viewed upstream) 2642-0482
215 17-MD-758-359 Turbine – Terminal Box 2644-0232
216 17-MD-758-360 Hydraulic Outline 2675-0049
217 17-MD-758-361 Surface Fairness – Individual Kaplan – Blade 2678-0171
218 17-MD-758-362 Surface Finish – Individual Kaplan – Blade 2678-0172
219 17-MD-758-363 Kaplan Blade – Outlet Edge – Template Signoff
2678-0173
220 17-MD-758-364 Kaplan Blade – Inlet Edge – Template Signoff
2678-0174
221 17-MD-758-365 Blade Tilt and Vent – Adjustable Blade – Kaplan Runner
2678-0175
222 17-MD-758-366 Thickness and Shape – Individual Kaplan – Blade
2678-0176
223 17-MD-758-367 Rexroth Manifold Assembly 2695-0182
224 17-MD-758-368 Rexroth Manifold Assembly 2695-0183
225 17-MD-758-369 Rexroth Bar Manifold 2695-0184
226 17-MD-758-370 Rexroth Governor System Schematic 2695-0185
227 17-MD-758-371 Rexroth Hyd Pump Arrangement 2695-0186
228 17-MD-758-372 Eight Bottle Accumulator Rack Assembly 2695-0199
229 17-MD-758-373 Minidoka Replacement Powerplant – Electrical Installation
Not Available
Amendment No. 005
Revised 52 00 00 - 14
Table 52 00 00A - List of Drawings
Sheet No.
Drawing No. Title Manufacturer’s Drawing No.
230 17-MD-758-374 Minidoka Replacement Powerplant – Electrical Installation
Not Available
231 17-MD-758-375 Minidoka Replacement Powerplant – Electrical Installation
Not Available
232 17-MD-758-376 Minidoka Replacement Powerplant – Electrical Installation
Not Available
233 17-MD-758-377 Minidoka Replacement Powerplant – Electrical Installation
Not Available
234 17-MD-758-378 Minidoka Replacement Powerplant – Electrical Installation
Not Available
235 17-MD-758-379 Minidoka Replacement Powerplant – Electrical Installation
Not Available
236 17-MD-758-380 Minidoka Replacement Powerplant – Electrical Installation
Not Available
237 17-MD-758-381 Bearing Pump Unit 2698-1478
238 17-MD-758-382 Motor Pump Group H.P. Lift Skid 2698-1479
239 17-MD-758-383 High Pressure Lift Skid 2698-1596
240 17-MD-758-384 Bearing Pumping Unit 2698-1597
241 17-MD-758-385 Cover Lift Cylinder 2698-1647
242 Not Available Sectional Drawing of Generator 0F3830-1
243 Not Available Coupling Bolt 3F5085
244 Not Available Scheme for High Pressure Oil Device 3F4997
245 Not Available Brake Device 2F3273
246 Not Available Main Shaft 1F2093
247 17-MD-758-32 Assembly of Bearing Unit 9 1F2089
248 Not Available Assembly of Bearing for No. 8 of Minidoka 1F2268
249 Not Available Outline – Governor Pumping Unit 2641-0068
250 Not Available Bearing Pumping Unit 2612-0687
Standard Drawings:
Amendment No. 005
Revised 52 00 00 - 15
Table 52 00 00A - List of Drawings
Sheet No.
Drawing No. Title Manufacturer’s Drawing No.
251 40-D-7101 Governor Systems – Digital Governor Control Algorithm
N/A
252 40-D-7102 Government Drawing Format – Drawing Boarder, Sample Title Block and Signature Lines
253 104-D-1165 Main Control Board CSA – Panel 7R – Wiring N/A
Amendment No. 005
Revised 52 00 00 - 16
Table 52 00 00B - Drawings in Numerical Order.
Drawing No. Sheet No. Manufacturer’s Drawing No.
17-107-
17-107-2000 1 N/A
17-D-
17-D-2039 6 N/A
17-D-2187 3 N/A
17-D-2189 2 N/A
17-D-2201 4 N/A
17-D-2201 59b N/A
17-D-2202 5 N/A
17-D-2418 59a N/A
17-D-2726 7 N/A
17-D-2727 8 N/A
17-D-2728 9 N/A
17-D-2729 10 N/A
17-D-2730 11 N/A
17-D-2731 12 N/A
17-D-2736 13 N/A
17-D-2737 14 N/A
17-D-2738 15 N/A
17-D-2739 16 N/A
17-D-2740 17 N/A
17-D-2741 18 N/A
17-D-2742 19 N/A
17-D-2743 20 N/A
59b sdurham Rectangle sdurham Rectangle sdurham Rectangle sdurham Text Box = Governor and Bearing Oil Pumping Units New Location sdurham Rectangle sdurham Text Box Keep clear for crane access sdurham Rectangle sdurham Text Box Keep clear for crane access cgouker Typewritten Text
FOR INFORMATION ONLY
cgouker Line cgouker Line