QAP E0004 E28.pdf

PDF 2 MB Posted

Attached to
SPE60320R0517 - NAS JRB DALLAS/FT. WORTH, TX - SOLICITATION
Solicitation number
SPE60320R0517
Issued by

About this file

This document is a Supplemental Quality Assurance Provision (SQAP) outlining contractor responsibilities for inspection and testing of petroleum products in storage. The SQAP requires contractors to perform routine on-site tests including sampling of storage tanks and shipments according to ASTM standards, retaining product samples for specified periods, determining the presence of water, density, temperature, appearance, color, and flash point of products. Tests must be included in the monthly service charge with some exceptions. The contractor must also furnish representative samples upon request and permit government use of testing equipment. The related federal contract opportunity is a solicitation from the Defense Logistics Agency Energy for petroleum product storage services at NAS JRB Dallas/Fort Worth, TX, with no further details provided.

View the file

Other files

File Type Posted
SF1449 Conformed 5-10-21.pdf PDF
Amendment 0009.pdf PDF
QA.pdf PDF
Amendment 0008.pdf PDF
Amendment 0007.pdf PDF
WD 2015-5231 Rev 16 12-21-20.pdf PDF
PWS January 06 2021 with Changes.pdf PDF
SF1449 Conformed 1-28-21.pdf PDF
Amendment 0006.pdf PDF
Amendment 0005.pdf PDF
SF1449 Conformed Oct 1 2020.pdf PDF
Attachment VI-DLA Form 2019.pdf PDF
SF1449 Conformed Sept 22 2022.pdf PDF
Amendment 0004.pdf PDF
Technical QA.pdf PDF
PWS Sept 22 2020.pdf PDF
Contracting QA.pdf PDF
Amendment 0003.pdf PDF
Amendment 0002.pdf PDF
Amendment 0001.pdf PDF
Attachment II PPQ.pdf PDF
Attachment VII QAPs.pdf PDF
Attachment V WD.pdf PDF
Attachment VI Form 19.3.pdf PDF
Attachment I PWS.pdf PDF
QAP E0002 E1.11.pdf PDF
QAP E0007 E35.pdf PDF
Attachment IV PP References.pdf PDF
QAP E0003 E22.pdf PDF
Attachment III PP Consent Form.pdf PDF
SF1449.pdf PDF
QAP E0005 E29.pdf PDF
QAP E0001 E1.01.pdf PDF
QAP E0006 E30.01.pdf PDF
Show all 34

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PDF (DLA)DLA FORM 1889, OCT 2011

SUPPLEMENTAL QUALITY ASSURANCE PROVISION (SQAP)

SHEET 1 OF 2PREVIOUS EDITION IS USABLE Add Continuation Page

Print Form Email Form Clear Export Data Import Data About Check for Newer Version Contact Us

REV DESCRIPTION DATE APPROVED

ENERGY QAP E28 December 2011

REVISIONS

E28 CONTRACTOR INSPECTION RESPONSIBILITIES (STORAGE)

(a) Inspection and tests by the Government of services, facilities, and equipment specified within this contract does not relieve the Contractor from responsibility to meet all requirements of the contract.

(b) The Contractor shall furnish personnel, facilities, and equipment on-site to accomplish the following routine tests and procedures. These on-site resources may be provided by Contractor personnel or by a commercial source action on behalf of the Contractor. The Quality Representative will not be responsible for performing any of these services for the Contractor.

(1) Sampling of storage tanks, shipments and receipts in accordance with ASTM D 4057, Standard Practice for Manual Sampling of Petroleum and Petroleum Products (API Manual of Petroleum Measurement Standards (MPMS), Chapter 8.1);

(2) Retaining of product composite samples from shipments and receipts as follows:

MINIMUM

METHOD OF SHIPMENT MINIMUM QUANTITY RETENTION PERIOD

Pipeline 20 liters 60 days

Tanker/Barge Parcel Composite 20 liters 90 days Each compartment 0.5 liters 90 days

Navy Fleet Oilers/Vessels 10 liters 60 days

Tank Truck/Car 1 liter 15 days

NOTE: After the minimum retention period, samples shall be tested for Appearance, Color (Visual), API Gravity/Density and Flash Point and, if found to be on-specification, shall be returned to like Government stock on-site. Sample containers may be reused if properly cleaned.

(3) Determining the presence of water in storage tanks, shipments and receipts. Ensure that accurate water cuts are obtained by means of a water indicating paste conforming to MIL-W-83779B. Two suggested sources are Stewart Hall Chemical Testmaster Water Indicating Paste or Sartomer Sar Gel Water Indicating Paste (see Note 2 below);

(4) Determining Density at 15 degrees Celsius or API gravity of products by ASTM D 1298 or ASTM D 4052 (see Note 2 below);

(5) Determining the temperature of products by the API MPMS, Chapter 7 (see Note 2 below);

(6) Determining the Appearance of applicable products using ASTM D 4176, Procedure 1 (see Note 2 below);

(7) Determining the visual color of products.

(8) Determining the Flash Point of applicable products using test methods cited in the appropriate product specification (see Note 2 below);

(9) Conversion of gross to net gallonage (liters);

(10) Determining the percentage (volume) of fuel system icing inhibitor (FSII) by means of a portable refractometer in accordance with ASTM D 5006. One suggested source is H.B. Industries, Inc., Glenview, IL 60025 (B/2 Anti-Icing Additive test kit) (see Note 2 below); and

(11) Determining the range of fuel electrical conductivity using ASTM D 2624. One suggested source for a conductivity meter is Emcee Electronics, Inc., Sarasota, FL 33581 (Model 1152) (see Note 2 below)

SUPPLEMENTAL QUALITY ASSURANCE PROVISION (SQAP)

DISTRIBUTION

STATEMENT - A

APPROVED FOR

PUBLIC RELEASE

DISTRIBUTION IS

"UNLIMITED"

DATE

09/22/2016

APPROVED BY

DATEREVIEWED BY

DATE

11/12/2013

PREPARED BY

DRAWING NUMBERSCALE

CODE ID NO.

52838

SIZE

NSN

MULTIPLE

ITEM

ENERGY QAP E28

DLA Land & Maritime DLA Troop Support DLA Aviation clear

DEFENSE ENERGY SUPPORT CENTER

8725 JOHN J. KINGMAN RD

FORT BELVOIR, VIRGINIA 22060-6222

DLA Energy

PDF (DLA)DLA FORM 1889, OCT 2011

SUPPLEMENTAL QUALITY ASSURANCE PROVISION (SQAP)

SHEET 2 OF 2PREVIOUS EDITION IS USABLE Add Continuation Page

Print Form Email Form Clear Export Data Import Data About Check for Newer Version Contact Us

REV DESCRIPTION DATE APPROVED

ENERGY QAP E28 December 2011

REVISIONS

Note 1: All costs for providing the above tests and procedures shall be included in the monthly service charge. The only exception to the Contractor's obligation to provide these services as part of the monthly service charge is when the tests described above are part of the higher order analysis (defined as the following categories: Composite Samples, Storage Tanks After Receipt, Interface Mixtures, Dormant Stocks and Individual Tests (including particulate contamination) found in the attachment to the solicitations entitled MINIMUM REQUIREMENTS FOR STORAGE SAMPLING AND TESTING. Provisions for providing higher order analyses are covered in the SAMPLING AND TESTING OF PETROLEUM PRODUCTS (STORAGE) contract provision.

Note 2: Upon request, the Contractor shall permit the Quality Representative unrestricted use of the equipment and ancillary supplies needed to perform this test/procedure on behalf of the Government.

(c) During the contract, the Contractor shall furnish representative samples of the product in each storage tank, shipment or receipt at the request of, and in the manner and to the place designated by, the Quality Representative. Sample size will be 2 gallons for gasoline-type fuels and one gallon or 10 gallons for jet diesel-type fuels. The number of samples to be furnished during any 12-month period shall not exceed eight times the number of tanks specified in the contract. Such samples shall be packed, marked, and shipped by the Contractor, shipping expense prepaid, in containers and shipping boxes furnished by the Contractor. Sample containers shall be epoxy coated on the interior. This requirement is in addition to sampling required elsewhere in this contract provision and the contract. All reasonable direct shipping costs associated with samples required by this paragraph shall be reimbursed upon request from the Contractor and such costs shall not be included in the monthly service charge.

However, all other costs related to this requirement shall be included as part of the monthly service charge.

DISTRIBUTION STATEMENT - A

APPROVED FOR PUBLIC RELEASE

DISTRIBUTION IS "UNLIMITED"

SUPPLEMENTAL QUALITY ASSURANCE PROVISION

(SQAP)

DRAWING NUMBERSCALE CODE ID NO.

52838

SIZE

DEFENSE ENERGY SUPPORT CENTER

8725 JOHN J. KINGMAN RD

FORT BELVOIR, VIRGINIA 22060-6222

PDF (DLA)

DLA FORM 1889, OCT 2011

SUPPLEMENTAL QUALITY ASSURANCE PROVISION (SQAP)

SHEET OF

PREVIOUS EDITION IS USABLE

REV

DESCRIPTION

DATE

APPROVED

REVISIONS

SUPPLEMENTAL QUALITY ASSURANCE PROVISION (SQAP)

DISTRIBUTION STATEMENT - A

APPROVED FOR PUBLIC RELEASE

DISTRIBUTION IS "UNLIMITED"

REV

DESCRIPTION

DATE

APPROVED

REVISIONS

DISTRIBUTION STATEMENT - A

APPROVED FOR PUBLIC RELEASE

DISTRIBUTION IS "UNLIMITED"

SUPPLEMENTAL QUALITY ASSURANCE PROVISION (SQAP)

Supplemental Quality Assurance Provision (SQAP) DSCC Form 2291, Feb 2004 online none standard Quality Assurance

DLA

1 + No Tech Qual Deskbook n/a No Supplemental Quality Assurance Provision (SQAP) interactive October 2011 (added Energy; updated supply center names)

CurrentPage:
PageCount:
btnPrint:
btnEmail:
btnClear:
btnExport:
btnImport:
btnAbout:
btnChkVersion:
btnContactUs:
Button1:
rev:
description: ENERGY QAP E28
revdate: December 2011
revapproved:
revcomments:
apprdate: 2016-09-22
apprBy:
reviewdate:
revBy:
prepdateA: 2013-11-12
prepbyA:
drawingNum:
scale:
codeIDNo: 52838
size:
nsn: MULTIPLE
itemdesc: ENERGY QAP E28
btnDSCC:
btnDSCP:
btnDSCR:
line1: DEFENSE ENERGY SUPPORT CENTER
line2: 8725 JOHN J. KINGMAN RD
line3: FORT BELVOIR, VIRGINIA 22060-6222
revcomments2:
totInstances: 1.00000000

File details come from the government source that posted it. Updated .