PWS Appendix F _FMP CMG_08.12.25.xlsx
XLSX spreadsheet 542 KB Posted
- Solicitation number
- W912DY26RA002
About this file
This file is a Performance Work Statement (PWS) Appendix F Facility Maintenance Plan for a fuel storage and dispensing facility located at Camp McCain in Grenada, Mississippi. The facility contains three fuel storage tanks: one 25,000-gallon Jet A tank, one 5,000-gallon diesel tank, and one 12,000-gallon mogas tank, with four total dispensers serving different fuel types. The detailed maintenance plan includes comprehensive tracking and maintenance requirements for various fuel system components, using specific Unified Facilities Criteria (UFC) section references for each asset.
The document provides an extensive task matrix detailing maintenance frequencies, special considerations, and unique identifiers for multiple fuel system assets including storage tanks, ball valves, fueling hoses, dispensers, electric motors, pressure relief valves, and grounding systems. Each component is assigned a specific maintenance schedule, with frequencies ranging from periodic inspections to comprehensive ten-year overhauls. The maintenance plan emphasizes systematic tracking of equipment through Component Unique Identifiers (CUID) and includes specific manufacturer requirements, operator guidelines, and potential system availability impacts for each maintenance task.
View the file
Other files
Show all 39
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Administrative
| Location | Installation Name | Camp McCain, Grenada, MS |
| DLA Site Code | CMG | |
| RPSUID | 4606 | |
| Hours of Operation | 7:00 am to 4:00 pm M-F | |
| Address | Camp McCain 3152 James H. Biddy Rd. Building S112 Grenada, MS 38902 | |
| Contract | Contractor | |
| Contract # | ||
| Local POCs | FMSR Phone | |
| FMSR Email | ||
| Alt FMSR Phone | ||
| Alt FMSR Email | ||
| DLA/SCP POCs | DLA PM Phone | |
| DLA PM Email | ||
| SCP PM Phone | ||
| SCP PM Email | ||
| Contractor POCs | Contractor PM Phone | |
| Contractor PM Email | ||
| Contractor QC Phone | ||
| Contractor QC Email | ||
| Contractor SM Phone | ||
| Contractor SM Email | ||
| USACE POCs | USACE PM/COR Phone | |
| USACE PM/COR Email | ||
| USACE PE Phone | ||
| USACE PE Email | ||
| USACE KO Phone | ||
| USACE KO Email |
Appendix K - Facility Maintenance Plan
&P of &N
Instructions:
This table shows the minimum information required. Additional details should be included based on site specific requirements. Additional POCs may be required.
General Facility Descript
| Installation | # of Fueling Areas to Report |
| Camp McCain, Grenada, MS | Three |
| Description of Area: | |
| 3 Storage Tanks, four dispensers | The facility has one 25K gal Jet A tank that supply two Jet A dispensers (one hose each) and one bulk fuel loading header, one 5K gal diesel tank for one dispenser (one hose, and one 12K gal tank for one Mogas dispenser (two hoses). |
Appendix K - Facility Maintenance Plan
&P of &N
Instructions:
Include a general facility overview and description of each fuel system for the sites in accordance with UFC 3-460-01. Examples include: Bulk Storage Facilities, Aircraft Fueling Facilities, Marine and Dispensing Facilities, Ground Products Fueling Facilities, Alternate POL Facilities, and Support Facilities. Also include facility #s, facility names, fuel type, photos, and any other pertinent information.
Include Site Specific Conditions and Restrictions in this tab.
Communication Plan
Appendix K - Facility Maintenance Plan
&P of &N
Instructions:
Communication plan shall address in/out briefs, lines of communication, etc.
Safety
Appendix K - Facility Maintenance Plan
&P of &N
Instructions:
Site Specific Addendum and Activity Hazard Analysis, which are Attachments to the APP, specific to activities or tasks related to recurring maintenance for this site.
PM Schedule
Instructions:
Link PM schedule here
Task Matrix
| Applicable Facility Assets | UFC System Level Maintenance Frequency | Special Considerations | |||||||||||||||||||
| DLA | |||||||||||||||||||||
| (EBS) Facility # | Army Facility # | Navy (iNFADS) Facility # | Air Force (ACESRPFM/ NEXGEN) Facility # | Real Property Unique Identifier | Facility Name | Operational Area | Component Type | CUID | Make | Model | Capacity/Size | Q | S | A | UFC Section Reference | Manufacturer Requirements | Operator/ equipment Requirements | System availability | Other Contract | Comments | |
| FTK02 | FTK02 | 993411 | Diesel/JP8 Above Grd Stor Tank | Diesel Tank | Aboveground Field-Erected Tanks | CMG-0FTK02-AGFET-0001 | 5000.00 | X | X | 8-4 | SM | TI | API 653 | ||||||||
| 9TANK | 9TANK | 271489 | Diesel/JP8 Above Grd Stor Tank | Jet A Tank | Aboveground Field-Erected Tanks | CMG-09TANK-AGFET-0001 | 25000.00 | X | 8-4 | SM | TI | API 653 | |||||||||
| TK309 | TK309 | 1325090 | FUEL STR ABV MOGAS | Mogas Tank | Aboveground Field-Erected Tanks | CMG-0TK309-AGFET-0001 | 12000.00 | X | 8-4 | SM | TI | API 653 | |||||||||
| OL001 | OL001 | 1301597 | TBA TRK LD UNLD | Jet A | Aircraft Fueling Hoses | CMG-0OL001-ACFHS-0001 | Hewitt | 4113 Aviation fueling Hose | 2" x 20' | X | X | 4-7.5 | SM | PI | |||||||
| OL002 | OL002 | 1302542 | TBA TRK LD UNLD | Jet A | Aircraft Fueling Hoses | CMG-0OL002-ACFHS-0001 | Continental | Futura | 15'x 1" | X | X | 4-7.5 | SM | PI | |||||||
| GN309 | GN309 | 1126638 | STANDBY GEN | Generator | Back-Up Power Generators | 80.00 | SM | TI | Performed by DPW | ||||||||||||
| FTK02 | FTK02 | 993411 | Diesel/JP8 Above Grd Stor Tank | Diesel | Ball Valves | CMG-0FTK02-BLVL-0001 | Flowtek | 1" | X | 6-6.2.4 | SM | NIS | |||||||||
| FTK02 | FTK02 | 993411 | Diesel/JP8 Above Grd Stor Tank | Diesel | Ball Valves | CMG-0FTK02-BLVL-0002 | Flowtek | 1" | X | 6-6.2.4 | SM | NIS | |||||||||
| FTK02 | FTK02 | 993411 | Diesel/JP8 Above Grd Stor Tank | Diesel | Ball Valves | CMG-0FTK02-BLVL-0003 | Flowtek | 1" | X | 6-6.2.4 | SM | NIS | |||||||||
| FTK02 | FTK02 | 993411 | Diesel/JP8 Above Grd Stor Tank | Diesel | Ball Valves | CMG-0FTK02-BLVL-0004 | Flowtek | 1" | X | 6-6.2.4 | SM | NIS | |||||||||
| FTK02 | FTK02 | 993411 | Diesel/JP8 Above Grd Stor Tank | Diesel | Ball Valves | CMG-0FTK02-BLVL-0005 | Flowtek | 1" | X | 6-6.2.4 | SM | NIS | |||||||||
| MO309 | MO309 | TBA VEH FUEL MOGAS | Mogas | Ball Valves | CMG-0MO309-BLVL-0001 | Flowtek | 4" | X | 6-6.2.4 | SM | NIS | ||||||||||
| OL001 | OL001 | 1301597 | TBA TRK LD UNLD | Jet A Loading Header | Ball Valves | CMG-0OL001-BLVL-0001 | X | 6-6.2.4 | SM | NIS | |||||||||||
| OL002 | OL002 | 1302542 | TBA TRK LD UNLD | Jet A Offload Header | Ball Valves | CMG-0OL002-BLVL-0001 | X | 6-6.2.4 | SM | NIS | |||||||||||
| OL003 | OL003 | 1326267 | TBA TRK LD UNLD | Diesel Off-Load? | Ball Valves | CMG-0OL003-BLVL-0001 | X | 6-6.2.4 | SM | NIS | |||||||||||
| OL001 | OL001 | 1301597 | TBA TRK LD UNLD | Jet A | Ball Valves | CMG-0OL001-BLVL-0002 | Flowtek | 1" | X | 6-6.2.4 | SM | NIS | |||||||||
| OL001 | OL001 | 1301597 | TBA TRK LD UNLD | Jet A | Ball Valves | CMG-0OL001-BLVL-0003 | Flowtek | 1" | X | 6-6.2.4 | SM | NIS | |||||||||
| OL001 | OL001 | 1301597 | TBA TRK LD UNLD | Jet A | Ball Valves | CMG-0OL001-BLVL-0004 | Flowtek | 1" | X | 6-6.2.4 | SM | NIS | |||||||||
| OL001 | OL001 | 1301597 | TBA TRK LD UNLD | Jet A | Ball Valves | CMG-0OL001-BLVL-0005 | Flowtek | 1" | X | 6-6.2.4 | SM | NIS | |||||||||
| OL001 | OL001 | 1301597 | TBA TRK LD UNLD | Jet A | Ball Valves | CMG-0OL001-BLVL-0006 | Flowtek | 1" | X | 6-6.2.4 | SM | NIS | |||||||||
| OL001 | OL001 | 1301597 | TBA TRK LD UNLD | Jet A | Ball Valves | CMG-0OL001-BLVL-0007 | Flowtek | 1" | X | 6-6.2.4 | SM | NIS | |||||||||
| OL001 | OL001 | 1301597 | TBA TRK LD UNLD | Jet A | Ball Valves | CMG-0OL001-BLVL-0008 | Flowtek | 1" | X | 6-6.2.4 | SM | NIS | |||||||||
| OL001 | OL001 | 1301597 | TBA TRK LD UNLD | Jet A | Ball Valves | CMG-0OL001-BLVL-0009 | Flowtek | 1" | X | 6-6.2.4 | SM | NIS | |||||||||
| OL001 | OL001 | 1301597 | TBA TRK LD UNLD | Jet A | Ball Valves | CMG-0OL001-BLVL-0010 | Flowtek | 1" | X | 6-6.2.4 | SM | NIS | |||||||||
| OL001 | OL001 | 1301597 | TBA TRK LD UNLD | Jet A | Ball Valves | CMG-0OL001-BLVL-0011 | 3" | X | 6-6.2.4 | SM | NIS | ||||||||||
| OL001 | OL001 | 1301597 | TBA TRK LD UNLD | Jet A | Ball Valves | CMG-0OL001-BLVL-0012 | 3" | X | 6-6.2.4 | SM | NIS | ||||||||||
| OL001 | OL001 | 1301597 | TBA TRK LD UNLD | Jet A | Ball Valves | CMG-0OL001-BLVL-0013 | 3" | X | 6-6.2.4 | SM | NIS | ||||||||||
| OL001 | OL001 | 1301597 | TBA TRK LD UNLD | Jet A | Ball Valves | CMG-0OL001-BLVL-0014 | Apollo | CF8M | 2" | X | 6-6.2.4 | SM | NIS | ||||||||
| TK309 | TK309 | 1325090 | FUEL STR ABV MOGAS | Mogas | Ball Valves | CMG-0TK309-BLVL-0001 | Flowtek | 1" | X | 6-6.2.4 | SM | NIS | |||||||||
| TK309 | TK309 | 1325090 | FUEL STR ABV MOGAS | Mogas | Ball Valves | CMG-0TK309-BLVL-0002 | Flowtek | 1" | X | 6-6.2.4 | SM | NIS | |||||||||
| TK309 | TK309 | 1325090 | FUEL STR ABV MOGAS | Mogas | Ball Valves | CMG-0TK309-BLVL-0003 | Flowtek | 1" | X | 6-6.2.4 | SM | NIS | |||||||||
| TK309 | TK309 | 1325090 | FUEL STR ABV MOGAS | Mogas | Ball Valves | CMG-0TK309-BLVL-0004 | Flowtek | 1" | X | 6-6.2.4 | SM | NIS | |||||||||
| TK309 | TK309 | 1325090 | FUEL STR ABV MOGAS | Mogas | Ball Valves | CMG-0TK309-BLVL-0005 | Flowtek | 3" | X | 6-6.2.4 | SM | NIS | |||||||||
| CB309 | CB309 | 1325797 | TBA POL CATCH BASIN | Mogas Dike | Ball Valves | CMG-0CB309-BLVL-0001 | Flowtek | 2" | X | 6-6.2.4 | SM | NIS | |||||||||
| FPM02 | FPM02 | 993412 | Diesel/JP8 to Veh Disp Pump | Diesel | Breakaways | CMG-0FPM02-DSBW-0001 | OPW | 66V | 1" | 7-4 | SM | PI | |||||||||
| MO309 | MO309 | TBA VEH FUEL MOGAS | Mogas | Breakaways | CMG-0MO309-DSBW-0001 | OPW | 3/4" | 7-4 | SM | PI | |||||||||||
| MO309 | MO309 | TBA VEH FUEL MOGAS | Mogas | Breakaways | CMG-0MO309-DSBW-0002 | OPW | 3/4" | 7-4 | SM | PI | |||||||||||
| OL002 | OL002 | 1302542 | TBA TRK LD UNLD | Jet A Dispenser 1 | Breakaways | CMG-0OL002-DSBW-0001 | 7-4 | SM | PI | ||||||||||||
| OL002 | OL002 | 1302542 | TBA TRK LD UNLD | Jet A Dispenser 2 | Breakaways | CMG-0OL002-DSBW-0002 | OPW | 1" | 7-4 | SM | PI | ||||||||||
| 0S309 | 0S309 | 271464 | VEH FUEL JP8 | Jet A Canopy | Canopies | CMG-00S309-CNPY-0001 | 4994.00 | 11-2.2 | SM | NIS | As Required | ||||||||||
| OL001 | OL001 | 1301597 | TBA TRK LD UNLD | Jet A | Check Valves | CMG-0OL001-CKVL-0001 | 3" - 150 | X | 6-6.2.8 | SM | NIS | ||||||||||
| CB309 | CB309 | 1325797 | TBA POL CATCH BASIN | Mogas Tank Containment | Containment Systems | CMG-0CB309-CSGEN-0001 | 5500.00 | X | 8-10.1 | OM | NIS | ||||||||||
| TK309 | TK309 | 1325090 | FUEL STR ABV MOGAS | Mogas | Diaphragm Pumps | CMG-0TK309-DIAP-0001 | Fil Rite | Series 5200 | 20gal per 100 strokes | X | 3-8.7 | SM | PI | As Required | |||||||
| FPM02 | FPM02 | 993412 | Diesel/JP8 to Veh Disp Pump | Diesel Dispenser | Dispenser Cabinet | CMG-0FPM02-DSCB-0001 | Gasboy | Gasboy-8753QX-IL S/R:MPGC013861 | X | X | 7-7 | SM | PI | ||||||||
| MO309 | MO309 | TBA VEH FUEL MOGAS | Mogas Dispenser | Dispenser Cabinet | CMG-0MO309-DSCB-0001 | Wayne | WAYNE-G5202D/27BGJK/ASW1 S/R:34124D H17 | X | X | 7-7 | SM | PI | |||||||||
| OL002 | OL002 | 1302542 | TBA TRK LD UNLD | Jet A Dispenser 1 | Dispenser Cabinet | CMG-0OL002-DSCB-0001 | Wayne | Wayne-3/G7221P/8HJK/M S/R:41821D | X | X | 7-7 | SM | PI | ||||||||
| OL002 | OL002 | 1302542 | TBA TRK LD UNLD | Jet A Dispenser 2 | Dispenser Cabinet | CMG-0OL002-DSCB-0002 | Wayne | Wayne-3/G7221P/8HJK/M S/R:41820D | X | X | 7-7 | SM | PI | ||||||||
| OL002 | OL002 | 1302542 | TBA TRK LD UNLD | Jet A Dispenser 2 | Dispenser Filters | CMG-0OL002-DSFLR-0002 | Cimtek | Centurion | X | 7-9 | SM | PI | |||||||||
| MO309 | MO309 | TBA VEH FUEL MOGAS | Mogas Hose 1 | Dispenser Filters | CMG-0MO309-DSFLR-0001 | Cimtek | 400-30 Pt # 70016 | X | 7-9 | SM | PI | ||||||||||
| MO309 | MO309 | TBA VEH FUEL MOGAS | Mogas Hose 2 | Dispenser Filters | CMG-0MO309-DSFLR-0002 | Cimtek | 400-30 Pt # 70016 | X | 7-9 | SM | PI | ||||||||||
| FPM02 | FPM02 | 993412 | Diesel/JP8 to Veh Disp Pump | Diesel | Dispenser Filters | CMG-0FPM02-DSFLR-0001 | Cimtek | 800-30 Pt # 70020 | 1" | X | X | 7-9 | SM | PI | |||||||
| OL002 | OL002 | 1302542 | TBA TRK LD UNLD | Jet A Dispenser 1 | Dispenser Filters | CMG-0OL002-DSFLR-0001 | Cimtek | Centurion | X | X | 7-9 | SM | PI | ||||||||
| FPM02 | FPM02 | 993412 | Diesel/JP8 to Veh Disp Pump | Diesel | Dispenser Nozzles | CMG-0FPM02-DSNZ-0001 | OPW | 7HB | 1" | X | X | 7-2 | SM | PI | |||||||
| MO309 | MO309 | TBA VEH FUEL MOGAS | Mogas Hose 1 | Dispenser Nozzles | CMG-0MO309-DSNZ-0001 | OPW | 3/4" | X | X | 7-2 | SM | PI | |||||||||
| MO309 | MO309 | TBA VEH FUEL MOGAS | Mogas Hose 2 | Dispenser Nozzles | CMG-0MO309-DSNZ-0002 | OPW | 3/4" | X | X | 7-2 | SM | PI | |||||||||
| OL002 | OL002 | 1302542 | TBA TRK LD UNLD | Jet A Dispenser 1 | Dispenser Nozzles | CMG-0OL002-DSNZ-0001 | OPW | 7HB | 1" | X | X | 7-2 | SM | PI | |||||||
| OL002 | OL002 | 1302542 | TBA TRK LD UNLD | Jet A Dispenser 2 | Dispenser Nozzles | CMG-0OL002-DSNZ-0002 | OPW | 7HB | X | 7-2 | SM | PI | |||||||||
| FPM02 | FPM02 | 993412 | Diesel/JP8 to Veh Disp Pump | Diesel | Emergency Shutoff Valves (Shear Valves) | CMG-0FPM02-ESHVL-0001 | X | 7-12 | SM | PI | |||||||||||
| MO309 | MO309 | TBA VEH FUEL MOGAS | Mogas | Emergency Shutoff Valves (Shear Valves) | CMG-0MO309-ESHVL-0001 | X | 7-12 | SM | PI | ||||||||||||
| FPM02 | FPM02 | 993412 | Diesel/JP8 to Veh Disp Pump | Diesel | Dispenser Sumps | CMG-0FPM02-DSSMP-0001 | X | 7-13 | OM | NIS | Every Three Years | ||||||||||
| MO309 | MO309 | TBA VEH FUEL MOGAS | Mogas | Dispenser Sumps | CMG-0MO309-DSSMP-0001 | X | 7-13 | OM | NIS | Every Three Years | |||||||||||
| OL002 | 1302542 | TBA TRK LD UNLD | Jet A Dispenser 1 | Dispenser Hoses | CMG-0OL002-DSHS-0001 | Continental | 1"x15" | X | 7-3 | SM | PI | ||||||||||
| OL002 | 1302542 | TBA TRK LD UNLD | Jet A Dispenser 2 | Dispenser Hoses | CMG-0OL002-DSHS-0002 | Continental | 1"x15" | X | 7-3 | SM | PI | ||||||||||
| FPM02 | 993412 | Diesel/JP8 to Veh Disp Pump | Diesel Dispenser | Dispenser Hoses | CMG-0FPM02-DSHS-0001 | Continental | 1"x15" | X | 7-3 | SM | PI | ||||||||||
| MO309 | TBA VEH FUEL MOGAS | Mogas Dispenser Hose 1 | Dispenser Hoses | CMG-0MO309-DSHS-0001 | Continental | 3/4"x10' | X | 7-3 | SM | PI | |||||||||||
| MO309 | TBA VEH FUEL MOGAS | Mogas Dispenser Hose 2 | Dispenser Hoses | CMG-0MO309-DSHS-0002 | Continental | 3/4"x10' | X | 7-3 | SM | PI | |||||||||||
| OL002 | 1302542 | TBA TRK LD UNLD | Jet A Dispenser 1 | Dispenser Hoses | CMG-0OL002-DSHS-0003 | Continental | 1" | X | 7-3 | SM | PI | ||||||||||
| OL002 | 1302542 | TBA TRK LD UNLD | Jet A Dispenser 2 | Dispenser Hoses | CMG-0OL002-DSHS-0004 | Continental | 1" | X | 7-3 | SM | PI | ||||||||||
| FPM02 | 993412 | Diesel/JP8 to Veh Disp Pump | Diesel Dispenser | Dispenser Hoses | CMG-0FPM02-DSHS-0002 | Continental | 1" | X | 7-3 | SM | PI | ||||||||||
| MO309 | TBA VEH FUEL MOGAS | Mogas Dispenser Hose 1 | Dispenser Hoses | CMG-0MO309-DSHS-0003 | Continental | 3/4" | X | 7-3 | SM | PI | |||||||||||
| MO309 | TBA VEH FUEL MOGAS | Mogas Dispenser Hose 2 | Dispenser Hoses | CMG-0MO309-DSHS-0004 | Continental | 3/4" | X | 7-3 | SM | PI | |||||||||||
| OL002 | 1302542 | TBA TRK LD UNLD | Jet A Dispenser 1 | Electric Motors | CMG-0OL002-ELEMT-0001 | X | X | 9-1.7 | SM | NIS | |||||||||||
| OL002 | 1302542 | TBA TRK LD UNLD | Jet A Dispenser 2 | Electric Motors | CMG-0OL002-ELEMT-0002 | X | X | 9-1.7 | SM | NIS | |||||||||||
| OL002 | 1302542 | TBA TRK LD UNLD | Jet A Dispenser 1 | Electric Motors | CMG-0OL002-ELEMT-0003 | X | X | 9-1.7 | SM | NIS | |||||||||||
| OL002 | 1302542 | TBA TRK LD UNLD | Jet A Dispenser 2 | Electric Motors | CMG-0OL002-ELEMT-0004 | X | X | 9-1.7 | SM | NIS | |||||||||||
| OL002 | 1302542 | TBA TRK LD UNLD | Jet A Dispenser 1 | Dispenser Strainers | CMG-0OL002-DSSTR-0001 | 7-10 | SM | PI | |||||||||||||
| OL002 | 1302542 | TBA TRK LD UNLD | Jet A Dispenser 2 | Dispenser Strainers | CMG-0OL002-DSSTR-0002 | 7-10 | SM | PI | |||||||||||||
| OL002 | 1302542 | TBA TRK LD UNLD | Jet A Dispenser 1 | Dispenser Strainers | CMG-0OL002-DSSTR-0003 | 7-10 | SM | PI | |||||||||||||
| OL002 | 1302542 | TBA TRK LD UNLD | Jet A Dispenser 2 | Dispenser Strainers | CMG-0OL002-DSSTR-0004 | 7-10 | SM | PI | |||||||||||||
| FPM02 | 993412 | Diesel/JP8 to Veh Disp Pump | Diesel Dispenser | Dispenser Strainers | CMG-0FPM02-DSSTR-0001 | 7-10 | SM | PI | |||||||||||||
| MO309 | TBA VEH FUEL MOGAS | Mogas Dispenser Hose 1 | Dispenser Strainers | CMG-0MO309-DSSTR-0001 | 7-10 | SM | PI | ||||||||||||||
| OL002 | 1302542 | TBA TRK LD UNLD | Jet A Dispenser 1 | Gear Pumps | CMG-0OL002-GERP-0001 | X | 3-8.6 | SM | PI | ||||||||||||
| OL002 | 1302542 | TBA TRK LD UNLD | Jet A Dispenser 2 | Gear Pumps | CMG-0OL002-GERP-0002 | X | 3-8.6 | SM | PI | ||||||||||||
| OL002 | 1302542 | TBA TRK LD UNLD | Jet A Dispenser 1 | Gear Pumps | CMG-0OL002-GERP-0003 | X | 3-8.6 | SM | PI | ||||||||||||
| OL002 | 1302542 | TBA TRK LD UNLD | Jet A Dispenser 2 | Gear Pumps | CMG-0OL002-GERP-0004 | X | 3-8.6 | SM | PI | ||||||||||||
| OL002 | 1302542 | TBA TRK LD UNLD | Jet A Dispenser 1 | Dispenser Meters | CMG-0OL002-DSMTR-0001 | X | 7-8 | SM | PI | ||||||||||||
| OL002 | 1302542 | TBA TRK LD UNLD | Jet A Dispenser 2 | Dispenser Meters | CMG-0OL002-DSMTR-0002 | X | 7-8 | SM | PI | ||||||||||||
| OL002 | 1302542 | TBA TRK LD UNLD | Jet A Dispenser 1 | Dispenser Meters | CMG-0OL002-DSMTR-0003 | X | 7-8 | SM | PI | ||||||||||||
| OL002 | 1302542 | TBA TRK LD UNLD | Jet A Dispenser 2 | Dispenser Meters | CMG-0OL002-DSMTR-0004 | X | 7-8 | SM | PI | ||||||||||||
| FPM02 | 993412 | Diesel/JP8 to Veh Disp Pump | Diesel Dispenser | Dispenser Meters | CMG-0FPM02-DSMTR-0001 | X | 7-8 | SM | PI | ||||||||||||
| MO309 | TBA VEH FUEL MOGAS | Mogas Dispenser Hose 1 | Dispenser Meters | CMG-0MO309-DSMTR-0001 | X | 7-8 | SM | PI | |||||||||||||
| MO309 | TBA VEH FUEL MOGAS | Mogas Dispenser Hose 2 | Dispenser Meters | CMG-0MO309-DSMTR-0002 | X | 7-8 | SM | PI | |||||||||||||
| OL001 | OL001 | 1301597 | TBA TRK LD UNLD | Jet A | Dual Pressure Relief, Solenoid Shutoff, and Check Valves | CMG-0OL001-DPSCVL-0001 | Snap Tite | LR87427; Z62114BLVGA19877 | 3" | X | 4-3.3.2 | SM | PI | Every 10 Years | When 10 yr overhaul is performed, complete system shutdown is req'd | ||||||
| OL001 | OL001 | 1301597 | TBA TRK LD UNLD | Jet A | Electric Motors | CMG-0OL001-ELEMT-0001 | Baldor | L BU161207 | X | X | X | 9-1.7 | SM | NIS | |||||||
| OL001 | OL001 | 1301597 | TBA TRK LD UNLD | Jet A | Electric Motors | CMG-0OL001-ELEMT-0002 | Nidec | M-18; C65749862, P56SX205 | 1/2 hp, 650 RPM, | X | X | X | 9-1.7 | SM | NIS | ||||||
| TK309 | TK309 | 1325090 | FUEL STR ABV MOGAS | Mogas | Electronic Equipment | CMG-0TK309-ELTREQ-0001 | Magnatrol Valve Corp. | F42KV37-HF1; Serial: 1442916 | 120V; 60HZ; 60 Watts; 200 PSI | 9-1.9 | SM | NIS | |||||||||
| FTK02 | FTK02 | 993411 | Diesel/JP8 Above Grd Stor Tank | Diesel | Emergency Vents | CMG-0FTK02-EMGVT-0001 | Morrison Bros Co | FIG 244 | 8oz/per Sq Inch; 2.5PSI | X | 8-9.4 | SM | NIS | ||||||||
| TK309 | TK309 | 1325090 | FUEL STR ABV MOGAS | Mogas | Emergency Vents | CMG-0TK309-EMGVT-0001 | Morrison Bros Co | FIG 244 | 8 oz/per Sq Inch; 2.5PSI | X | 8-9.4 | SM | NIS | ||||||||
| OL001 | OL001 | 1301597 | TBA TRK LD UNLD | Jet A | External High Level Shutoff Valves (HLSO) | CMG-0OL001-EHLSVL-0001 | Cla Val | 413-01-99G | 3" | 8-9.6.1 | SM | MI | BAE has this responsibility | ||||||||
| OL001 | OL001 | 1301597 | TBA TRK LD UNLD | Jet A | Externally Mounted Level Alarms | CMG-0OL001-EMLA-0001 | Veeder Root | X | 8-9.9.1 | SM | NIS | BAE has this responsibility | |||||||||
| FJL00 | FJL00 | 261091 | 0S309 FENCE | Fence | Fencing | CMG-0FJL00-FENC-0001 | 944.00 | SM | NIS | ||||||||||||
| OL001 | OL001 | 1301597 | TBA TRK LD UNLD | Jet A | Filter Separators | CMG-0OL001-FLSP-0001 | Velcon | HV163315OMT; SO65927-3 | X | 3-6.2 | SM | TI | Every Three Years | Routine coalescer changes for sites that do not self perform shall be priced under CLIN 6 maintenance activities. Existing maintenance schedules when provided will be located in Appendix J. If no existing schedules have been provided, assume coalescer changes in Base Year and thereafter following the required service period indicated in this section. Coalescer changes required due to a repair, out of sequence, or other circumstance beyond normal system operation shall be performed by service order. Coalescer cartridges will be purchased by the Government and supplied to the Contractor. | |||||||
| OL001 | OL001 | 1301597 | TBA TRK LD UNLD | Jet A | Fire Valves | CMG-0OL001-FRVL-0001 | Morrison | 4"x3" | X | X | 6-6.4.1 | SM | NIS | ||||||||
| OL001 | OL001 | 1301597 | TBA TRK LD UNLD | JET A | Fueling Nozzles | CMG-0OL001-FLNZ-0001 | Cla Val | D-2; 2993301H | X | 4-7.3 | Cla-Val recommends rebuild annually | SM | PI | Cla-Val recommends replacing soft components annually | |||||||
| FJL00 | FJL00 | 261091 | 0S309 FENCE | Fence | Gates | CMG-0FJL00-GATE-0001 | Max Controls | MAX200 Pro; SN#03052021 3009, MAX Pro Solar | SM | NIS | |||||||||||
| OL001 | OL001 | 1301597 | TBA TRK LD UNLD | Jet A | Internal HLSO Valves | CMG-0OL001-IHLSVL-0001 | Cla Val | CFF21-H2 | 8-9.6.2 | SM | NIS | ||||||||||
| FTK02 | FTK02 | 993411 | Diesel/JP8 Above Grd Stor Tank | Diesel | Low Point Drains | CMG-0FTK02-LPDN-0001 | Nibco | 2" | X | 6-12.1 | OM | NIS | |||||||||
| OL001 | OL001 | 1301597 | TBA TRK LD UNLD | Jet A Refueling Header | Positive Displacement Meters | CMG-0OL001-PDMT-0001 | LC M-15-1 | 605422 | X | 3-7.1 | SM | MI | |||||||||
| OL001 | OL001 | 1301597 | TBA TRK LD UNLD | Jet A Refueling Header | Positive Displacement Meters | CMG-0OL001-PDMT-0002 | TCS 3000 | X | 3-7.1 | SM | MI | ||||||||||
| 0S309 | 0S309 | 271464 | VEH FUEL JP8 | Jet A Filter Separator | Pressure and Pressure/Vacuum Gauges | CMG-00S309-PVGA-0001 | X | X | X | 6-7.1 | SM | NIS | |||||||||
| OL001 | OL001 | 1301597 | TBA TRK LD UNLD | Jet A | Pressure and Pressure/Vacuum Gauges | CMG-0OL001-PVGA-0001 | Trerice | 0-200; 1/4" x 2.5" diameter | X | X | X | 6-7.1 | SM | NIS | |||||||
| FTK02 | FTK02 | 993411 | Diesel/JP8 Above Grd Stor Tank | Diesel Tank | Pressure Relief Valves | CMG-0FTK02-PRCVL-0001 | Taylor | 059257-54 | X | 4-3.2.6 | SM | PI | Every 10 Years | When 10 yr overhaul is performed, complete system shutdown is req'd | |||||||
| OL001 | OL001 | 1301597 | TBA TRK LD UNLD | Jet A | Pressure Relief Valves | CMG-0OL001-PRCVL-0001 | Taylor | 049232-50 | X | 4-3.2.6 | SM | PI | Every 10 Years | When 10 yr overhaul is performed, complete system shutdown is req'd | |||||||
| OL001 | OL001 | 1301597 | TBA TRK LD UNLD | Jet A | Pressure Relief Valves | CMG-0OL001-PRCVL-0002 | Taylor | 059297-53 | X | 4-3.2.6 | SM | PI | Every 10 Years | When 10 yr overhaul is performed, complete system shutdown is req'd | |||||||
| OL001 | OL001 | 1301597 | TBA TRK LD UNLD | Jet A | Pressure Relief Valves | CMG-0OL001-PRCVL-0003 | Taylor | 059297-57 | X | 4-3.2.6 | SM | PI | Every 10 Years | When 10 yr overhaul is performed, complete system shutdown is req'd | |||||||
| OL001 | OL001 | 1301597 | TBA TRK LD UNLD | Jet A | Pressure Relief Valves | CMG-0OL001-PRCVL-0004 | Taylor | 059297-55 | X | 4-3.2.6 | SM | PI | Every 10 Years | When 10 yr overhaul is performed, complete system shutdown is req'd | |||||||
| OL001 | OL001 | 1301597 | TBA TRK LD UNLD | Jet A | Pressure Relief Valves | CMG-0OL001-PRCVL-0005 | Taylor | 11013-7 | X | 4-3.2.6 | SM | PI | Every 10 Years | When 10 yr overhaul is performed, complete system shutdown is req'd | |||||||
| TK309 | TK309 | 1325090 | FUEL STR ABV MOGAS | Mogas Tank | Pressure Relief Valves | CMG-0TK309-PRCVL-0001 | Taylor | 059257-56 | X | 4-3.2.6 | SM | PI | Every 10 Years | When 10 yr overhaul is performed, complete system shutdown is req'd | |||||||
| OL001 | OL001 | 1301597 | TBA TRK LD UNLD | Jet A | Sliding Vane Pumps | CMG-0OL001-SLVP-0001 | Blackmer | X | 3-8.5 | SM | PI | ||||||||||
| FTK02 | FTK02 | 993411 | Diesel/JP8 Above Grd Stor Tank | Diesel | Static Grounding Systems | CMG-0FTK02-STGS-0001 | Reel craft | G3050; 13197928-08 | 50' | X | X | 9-1.6.2 | SM | NIS | |||||||
| MO309 | MO309 | TBA VEH FUEL MOGAS | Mogas | Static Grounding Systems | CMG-0MO309-STGS-0001 | Hannay Reels | HCR 50-50; Serial: 2649891 | 50' | X | X | 9-1.6.2 | SM | NIS | ||||||||
| OL001 | OL001 | 1301597 | TBA TRK LD UNLD | Jet A | Static Grounding Systems | CMG-0OL001-STGS-0001 | Reel craft | G3050, 1397928-08 | 50' | X | X | 9-1.6.2 | SM | NIS | |||||||
| FPM02 | FPM02 | 993412 | Diesel/JP8 to Veh Disp Pump | Diesel | Swivels | CMG-0FPM02-DSSW-0001 | OPW | 45-1 | 1" | X | 7-5 | SM | PI | ||||||||
| MO309 | MO309 | TBA VEH FUEL MOGAS | Mogas | Swivels | CMG-0MO309-DSSW-0001 | OPW | 3/4" | X | 7-5 | SM | PI | ||||||||||
| MO309 | MO309 | TBA VEH FUEL MOGAS | Mogas | Swivels | CMG-0MO309-DSSW-0002 | OPW | 3/4" | X | 7-5 | SM | PI | ||||||||||
| OL002 | OL002 | 1302542 | TBA TRK LD UNLD | Jet A | Swivels | CMG-0OL002-DSSW-0001 | OPW | 1" | X | 7-5 | SM | PI | |||||||||
| OL002 | OL002 | 1302542 | TBA TRK LD UNLD | Jet A | Swivels | CMG-0OL002-DSSW-0002 | X | 7-5 | SM | PI | |||||||||||
| FTK02 | FTK02 | 993411 | Diesel/JP8 Above Grd Stor Tank | Diesel | Vertical Turbine/Submerged Turbine Pumps | CMG-0FTK02-VTSP-0001 | FE Petro, Franklin Fueling Systems | STP75-VL2-07;serial: 05091270 | 208-230V; 6.1Amp;1PH;.75HP; 60 HZ | X | X | 3-8.3 | SM | PI | |||||||
| TK309 | TK309 | 1325090 | FUEL STR ABV MOGAS | Mogas | Vertical Turbine/Submerged Turbine Pumps | CMG-0TK309-VTSP-0001 | FE Petro, Franklin Fueling Systems | STP33-VL2-07; Serial: 17J501000055S | 208-230V; 3.1SF; 1PH; 1/3HP; 60HZ | X | X | 3-8.3 | SM | PI | |||||||
| P309A | P309A | NON ORG PARKING UNPAVED | Parking | 206.00 | |||||||||||||||||
| GP309 | GP309 | 1126568 | PAD | Mogas parking pad | 16.00 | ||||||||||||||||
| PK309 | PK309 | 1318183 | NON ORG PARKING PAVED | Parking | 180.00 | ||||||||||||||||
| PUMP | PUMP | ERROR:#N/A | ERROR:#N/A | No Idea | |||||||||||||||||
| QJL45 | QJL45 | 1111508 | ROADS, PAVED | Roads | 1648.00 | ||||||||||||||||
| S309A | S309A | 1166107 | FUEL OPERATIONS BUILDING - FAC. S309A | POL Building | 600.00 | ||||||||||||||||
| S309B | S309B | 1126783 | OVERHEAD PROTEC | Generator Canopy | 600.00 | ||||||||||||||||
| SJJ00 | SJJ00 | 1166188 | SIDEWALK | Sidewalk | 12.00 | ||||||||||||||||
| S309B | 1126783 | OVERHEAD PROTEC | Generator Canopy | Lighting | CMG-0S309B-LIGHT-0001 | 1 EA | X | 9-1.8 | SM | NIS | |||||||||||
| 0S309 | 271464 | VEH FUEL JP8 | Fuel Station Canopy | Lighting | CMG-00S309-LIGHT-0001 | 18 EA | X | 9-1.8 | SM | NIS |
&"Times New Roman,Bold"&14APPENDIX F - Facility Maintenance Plan
Instructions:
1. Input all data as indicated on the sheet.
2. Additional documents referred to in the Special Considerations column shall be included as an appendix to this FMP.
3. The contractor shall generate a Component Unique Identifier (CUID) for each component utilizing the Component Acronym Sheet within this Work Book. The unique identifier must use the following:
Three letter Site Code - Facility # - Component Acronym - Sequential number Example: AAD-00063A-RCVL-0001
If component acronym is not listed, the contractor shall request an acronym be established through the HNC Project Manager and Project Engineer via email. Contractors may utilize other means of tracking/labeling assets such as QR codes in addition to the required CUID however, tracking/labeling must correlate with the CUID. This CUID shall be the standard for all DLA capitalized equipment. Base Asset ID if used by site shall be cross referenced with CUID appropriately.
4. Utilize the UFC Section Reference Work Category as noted on the Component Acronym Sheet.
5. Enter any applicable manufacturer requirements not stated in the UFC. References are acceptable with attachments.
6. Enter any applicable operator support or government owned equipment required to complete the RM task.
7. Enter impact on system availability by performing the RM task. This could include shutdown, lockout, or similar impacts.
8. Enter contract information for any other contract, contractor, or government personnel performing the applicable task. This is applicable to other Centrally Managed Programs, SRM, MILCON, or Public Works/Civil Engineering projects.
9. Print Hard Copies as 11x17.
FS-PF Schedule
| FILTER SEPARATOR/PRE-FILTER MAINTENANCE SCHEDULES | |||||||||||||||||||||
| Applicable Facility Assets | Coalescer/Separator Information | Special Considerations | |||||||||||||||||||
| Real Property Unique Identifier | |||||||||||||||||||||
| (RPUID) | Real Property Facility # | Real Property Facility Name | Operational Area | Component Type | Base Asset ID | Component Unique Identifier (CUID) | Make | Model | Capacity (GPM) | UFC Section Reference | Number of Coalescer Cartridges | Number of | |||||||||
| Separator Cartridges | Coalescer Cartridges | ||||||||||||||||||||
| Model # | Separator Cartridge | ||||||||||||||||||||
| Model # | Clean or Replace | ||||||||||||||||||||
| Separator Cartridge | Gasket | ||||||||||||||||||||
| Model # | Date Last Replaced | Replacement Due Date | Operator/Equipment Requirements | System Availability | Site Self Performs | ||||||||||||||||
| (Y/N) | Comments | ||||||||||||||||||||
| 271489 | 9TANK | Diesel/JP8 Above Grd Stor Tank | Filter Separators (Section 3-6.2) | 271489 | Velcon | HV1633150MT/SO 659273 | 240 | 3-6.2 | 3 | 1 | 1-63387TB | SO-436C | Clean | Unknown | 1/1/23 | 1/1/26 | Contatc POL |
Component Acronym
| Component Unique Identifier: | Site Code-Facility #-Component Acronym-Sequential # | ||
| Example: | AAD-00063A-RCVL-0001 | ||
| NOTE: If component acronym is not listed, the contractor shall request an acronym be established through the HNC Project Manager and Project Engineer via email. Contractors may utilize other means of tracking/labeling assets such as QR codes in addition to the required CUID however, tracking/labeling must correlate with the CUID. This CUID shall be the standard for all DLA capitalized equipment | |||
| DLA Work Type Category | UFC Section Reference Work Category | ||
| (Revised per Change 1, 29 April 2021) | Component Acronym | ||
| Air Compressors | Air Compressors | AIRC | |
| Alarms | Externally Mounted Level Alarms (Section 8-9.9.1) | EMLA | |
| Internally Mounted Level Alarms (Section 8-9.9.3) | IMLA | ||
| Bollard | Bollards | BLRD | |
| Building | Building HVAC | BHVAC | |
| Building Domestic Water System | BWTR | ||
| Building Waste Water | BWSW | ||
| Building - Lighting | BLTG | ||
| Building - Architectural | BARCH | ||
| Building - Fire Sprinkler System | BFIRE | ||
| Containment/Joints | Containment Systems (General) (Section 8-10.1) | CSGEN | |
| Concrete and Cement Brick Dike/Berm Walls (Section 8-10.2.1) | DKBW | ||
| Dike/Berm Floors (Section 8-10.2.2) | DKBF | ||
| Earthen Dike Walls (Section 8-10.3) | ETHDW | ||
| Self-Diking or Vaulted Tank Containment (Section 8-10.4) | SDVTCS | ||
| Flexible Membrane Liners (Section 8-10.5) | FXML | ||
| Fuel Truck and Rail Car Containment Areas (Section 11-1.1) | FTKRCC | ||
| Remote Spill Containment (Section 11-1.2) | RSCS | ||
| Piers and Wharves Fuel Containment Systems (Section 5-1.2) - Testing | FPWCT | ||
| Fuel Pier/Wharf Containment (PWS Section 3) | FPWC | ||
| Corrosion Control/Coatings | Aboveground Piping and Equipment Coatings (Section 6-10.1) | AGPCT | |
| Miscellaneous | Miscellaneous Deactivated Components (Section 12-5) | MDEAC | |
| Electrical/Lighting | Lighting (Section 9-1.8) | LIGHT | |
| Electrical/Power | Electrical Equipment (Section 9-1.2) | ELEQ | |
| Power Cables (Section 9-1.3) | PWRCBL | ||
| Motor Controls (Section 9-1.4) | MTRCT | ||
| Panelboards (Section 9-1.5) | PNLB | ||
| Electric Motors (Section 9-1.7) | ELEMT | ||
| Electronic Equipment (9-1.9) | ELTREQ | ||
| Card and Key Locks (Section 9-3) | CKLK | ||
| Electrical/Protection | Power Grounding Systems (Section 9-1.6.1) | PWRGS | |
| Static Grounding Systems (Section 9-1.6.2) | STGS | ||
| Cathodic Protection (Section 9-2.1) | CP | ||
| Lightning Surge Arresters (Section 9-2.2.1) | LSAR | ||
| Lightning Protection Systems (Section 9-4) | LPTS | ||
| Ground Verification System (Section 9-5) | GRVS | ||
| Electronic Overfill Protection Systems (Section 9-6) | EOPS | ||
| Eyewash/Shower | Emergency Eyewash/Showers (Section 11-3) | EMEWSH | |
| Fencing/ | |||
| Gates | Fencing | FENC | |
| Gates | GATE | ||
| Filtration | Pre-Filters (Section 3-6.1) | PFVSL | |
| Filter Separators (Section 3-6.2) | FLSP | ||
| Haypack Filters (Section 3-6.3) | HPKF | ||
| Basket Strainers (Section 3-6.4) | BSTR | ||
| Filter Separator Sump Heaters (Section 3-6.5) | FSSH | ||
| Sidestream Filtration Systems (Section 8-9.11) | SSFTS | ||
| Fire Suppression Equipment | Flame Arrestors (Section 8-9.5) | FLMARR | |
| Foam Fire Protection Systems (Section 8-9.15) | FFPS | ||
| Fire Protection Systems - Wet Pipe | FPRS | ||
| Fuel Laboratories | Ventilation Hoods (Section 11-4.1) | VENTHD | |
| Gauges | Pressure and Pressure/Vacuum Gauges (Section 6-7.1) | PVGA | |
| Differential Pressure Gauges (Section 6-7.2) | DPGA | ||
| Mechanical Tape Gauges (Section 8-9.7) | MTGA | ||
| Mechanically Operated Tape Gauge (Section 8-9.8.1) | MOTGA | ||
| Magnetostrictive Probes (Section 8-9.8.2) | MRPRB | ||
| Servo Gauge (Section 8-9.8.3) | SRVGA | ||
| Generators | Back-Up Power Generators | BGEN | |
| Heating Coils | Steam Type Heating Coils (Section 8-9.16.1) | STHC | |
| Thermal Fluid Type Heating Coils (Section 8-9.16.2) | TFTHC | ||
| Electric Rod Type Heating (Section 8-9.16.3) | ERTH | ||
| Hoses | Loading Fuel Hoses (Section 3-9.1) | LDHS | |
| Offloading Fuel Hoses (Section 3-9.2) | OLHS | ||
| Aircraft Fueling Hoses (Section 4-7.5) | ACFHS | ||
| Hydrazine | Hydrazine Charging Units (Section 10-3) | HDZCU | |
| Inspections | Trouble Shoot | TRBST | |
| API 510 Inspections | API510 | ||
| API 653 or STI Inspection | API653 | ||
| Coatings Condition Survey | CCS | ||
| Issue/Receive - Ground | Dispenser Nozzles (Section 7-2) | DSNZ | |
| Dispenser Hoses (Section 7-3) | DSHS | ||
| Breakaways (Section 7-4) | DSBW | ||
| Swivels (Section 7-5) | DSSW | ||
| Hose Retriever (Section 7-6) | HSRTV | ||
| Dispenser Cabinet (Section 7-7) | DSCB | ||
| Dispenser Meters (Section 7-8) | DSMTR | ||
| Dispenser Filters (Section 7-9) | DSFLR | ||
| Dispenser Strainers (Section 7-10) | DSSTR | ||
| Ground Vehicle Fuel Piping (Section 7-11) | GVFP | ||
| Emergency Shutoff Valves (Shear Valves) (Section 7-12) | ESHVL | ||
| Dispenser Sumps (Section 7-13) | DSSMP | ||
| Transition Sumps (Section 7-14) | TRSMP | ||
| Remote Dispenser Pumps (Section 7-15.1) | RDSP | ||
| Self-Contained Dispenser Pumps (Section 7-15.2) | SCDSP | ||
| EFSO Systems (Section 7-16) | EFSO | ||
| Stage I Vapor Recovery (Section 7-17.1) | SIVP | ||
| Stage II Vapor Recovery (Section 7-17.2) | SIIVP | ||
| Vapor Burners (Section 7-17.3) | VPBNR | ||
| Point Sensor - Dry (Section 7-19.1.1) | PSDRY | ||
| Automatic Line Leak Detector (Section 7-19.1.2) | ALLD | ||
| Visual Monitoring (Section 7-20.1) | VSLM | ||
| Issue/Receive - Marine | Marine Receipt (Section 5-2) | MRNRCP | |
| Marine Issue (Section 5-3) | MRNISU | ||
| Marine Loading Arms (Section 5-4) | MRNLA | ||
| Marine Transfer Hoses (Section 5-5.1) | MBTHS | ||
| Underwater Hoses (Section 5-5.2) | UWHS | ||
| Single Point Mooring Systems (Section 5-7.1) | SPMSS | ||
| Multi Point Mooring Systems (Section 5-7.2) | MPMSS | ||
| Submerged Piping Systems (Section 5-8) | SMPS | ||
| Boom Reels (Section 5-9) | BMRL | ||
| Liquefied Petroleum | Liquefied Petroleum Tanks (Section 10-1.1) | LPTANK | |
| Liquefied Petroleum Pipelines (Section 10-1.2) | LPPIPE | ||
| Liquefied Petroleum Vapor Lines (Section 10-1.3) | LPVPL | ||
| LPG Vaporizers (Section 10-1.4) | LPGVPZ | ||
| Petroleum Gas Regulators (Section 10-1.5) | PGREG | ||
| Liquefied Petroleum Gas Hoses (Section 10-1.6) | LPGHS | ||
| Meter/ | |||
| calibrations | Positive Displacement Meters (Section 3-7.1) | PDMT | |
| Turbine Flow Meters (Section 3-7.2) | TBFMT | ||
| Orifice Flow Meters (Section 3-7.3) | OFMT | ||
| Natural Disaster | Natural Disaster | ||
| Natural Gas | CNG Piping (Section 10-2.1) | NGPIPE | |
| CNG Compressors (Section 10-2.2) | NGCOMP | ||
| CNG Storage (Section 10-2.3) | NGSTOR | ||
| CNG Dispensers (Section 10-2.4) | NGDS | ||
| CNG Dispenser Hoses (Section 10-2.5) | NGDSHS | ||
| Nozzle | Hydrant Adapters (Section 4-7.2) | HADP | |
| Fueling Nozzles (Section 4-7.3) | FLNZ | ||
| Other | Fuel Additive Injectors (Section 3-11) | FAIJ | |
| Pantograph | Fixed Pantographs (Section 4-7.1.1) | FXPNT | |
| Detachable Pantographs (Section 4-7.1.2) | DTPNT | ||
| Piping | On-Base Pipelines (Section 6-1.1) | OBPL | |
| Non-DOT Regulated (Section 6-1.2.1) | NDPL | ||
| Aboveground Piping (Section 6-1.3) | AGPL | ||
| Double-Wall Piping (Section 6-1.4) | DWPL | ||
| Low Point Drains (Section 6-12.1) | LPDN | ||
| High Point Vents (Section 6-12.2) | HPVT | ||
| Sight Flow Indicators (Section 6-12.3) | SFND | ||
| Rope Sensor Systems (Section 6-13.1.1) | RPSS | ||
| Point Sensor - Dry (Section 6-13.1.2) | PSDRY | ||
| Visual Monitoring (Section 6-14.1) | VSLM | ||
| Pipe Penetrations (Section 8-10.6) | PPEN | ||
| Deactivated Petroleum Fuel Pipelines (Section 12-3) | DEACPL | ||
| Pressure/Temperature Control | Air Eliminator Tanks (Section 3-10.1) | AELT | |
| Automatic Air Vents (Section 3-10.2) | AAVT | ||
| Surge Suppressors (Section 4-7.4) | SRGSP | ||
| Thermal and Pressure Relief Valves (Section 6-6.3) | TPRVL | ||
| Pressure Transmitters (Section 6-7.3) | PRTR | ||
| Differential Pressure Transmitters (Section 6-7.4) | DPTR | ||
| Flexible Ball Joints (Section 6-8) | FBLJT | ||
| Dial Thermometer (Section 6-9.1) | DTHMR | ||
| Emergency Vents (Section 8-9.4) | EMGVT | ||
| Pump | Centrifugal Pumps (Section 3-8.1) | CENP | |
| Vertical Inline Pumps (Section 3-8.2) | VILP | ||
| Vertical Turbine/Submerged Turbine Pumps (Section 3-8.3) | VTSP | ||
| Sliding Vane Pumps (Section 3-8.5) | SLVP | ||
| Gear Pumps (Section 3-8.6) | GERP | ||
| Diaphragm Pumps (Section 3-8.7) | DIAP | ||
| Internal Combustion Drives (Section 3-8.8) | ICDR | ||
| Gearboxes (Section 3-8.9) | GRBX | ||
| Deactivated Petroleum Fuel Pumps (Section 12-4) | DEACP | ||
| Signage/Markings | Signage and Markings (Section 2-7) | SIGN | |
| Structures | Pumphouse/Filter Buildings (Section 11-2.1) | PFBLDG | |
| Canopies (Section 11-2.2) | CNPY | ||
| Cranes and Hoists (Section 11-6) | CRNHST | ||
| Tank | Aboveground Field-Erected Tanks (Section 8-4) | AGFET | |
| Geodesic Dome Roofs (Section 8-4.2) | GEODR | ||
| Foundations (Section 8-4.3) | FOUND | ||
| Aboveground Shop Fabricated Tanks (Section 8-5.1) | AGSFP | ||
| Self-Diking or Vaulted Tanks (Section 8-5.2) | SDVT | ||
| Rectangular Concrete-Encased Tanks (Section 8-5.3) | RCET | ||
| Single-Walled Underground Shop-Fabricated Tanks (Section 8-5.4.1) | UGSSFT | ||
| Double-Walled Underground Shop-Fabricated Tanks (Section 8-5.4.2) | UGDSFT | ||
| Underground Field-Constructed Tanks (Cut and Cover Tanks) (Section 8-6) | UGFET | ||
| Tank Cleaning (Section 8-7) | TCLEAN | ||
| Aluminum Honeycomb Floating Pans (Section 8-9.1.1) | AHFP | ||
| Steel Floating Pans (Section 8-9.1.2) | STLFP | ||
| Pontoon Floating Pans (Section 8-9.1.3) | PTNFP | ||
| Floating Roofs (Section 8-9.1.4) | FLTRF | ||
| Floating Roof and Pan Pressure/Vacuum Vents (Section 8-9.1.5) | FPPVV | ||
| Floating Roof and Pan Legs (Section 8-9.1.6) | FRPLG | ||
| Secondary Tank Bottoms (Section 8-9.2) | SNDTB | ||
| Tank Pressure/Vacuum Vents (Section 8-9.3) | TPVVT | ||
| Product Saver Tanks (Section 8-9.10) | PRDST | ||
| Fill Ports (Section 8-9.12) | FPRT | ||
| Point Sensor - Dry (Section 8-9.13.1) | PSDRY | ||
| Point Sensor - Wet (Section 8-9.13.2) | PSWET | ||
| Point Sensor - Pressure/Vacuum (Section 8-9.13.3) | PSPV | ||
| Visual Leak Detection (Section 8-9.13.4) | VSLLD | ||
| Floating Suction Lines (Section 8-9.14) | FLTSL | ||
| Stilling Wells (Section 8-9.17) | STGW | ||
| Deactivated Petroleum Fuel Tanks (Section 12-2) | DEACT | ||
| Testing | Pressure Testing | ||
| Underground Pits | Isolation Valve Pits (Section 6-11.1) | ISVLP | |
| Hydrant Fuel Pits (Section 6-11.2) | HDFP | ||
| High Point Vent Pits (Section 6-11.3) | HPVP | ||
| Low Point Drain Pits (Section 6-11.4) | LPDP | ||
| Lateral Control Pits (Section 6-11.5) | LTCP | ||
| Valves | General System Control Valves (Section 4-3.2.1) | GSCVL | |
| Refuel Control Valves (Section 4-3.2.5) | RCVL | ||
| Pressure Relief Valves (Section 4-3.2.6) | PRCVL | ||
| Defuel Control Valve (Section 4-3.2.7) | DFCVL | ||
| Dual Rate-of-Flow Control Valves (Section 4-3.2.8) | DRFCVL | ||
| Combination Dual Rate-of-Flow Control and Solenoid Valves (Section 4-3.3.1) | CFSCVL | ||
| Dual Pressure Relief, Solenoid Shutoff, and Check Valves (Section 4-3.3.2) | DPSCVL | ||
| Non-Surge Check Valves (Section 4-4.2.1) | NSCKVL | ||
| Filter Separator Control Valves (Section 4-4.2.2) | FSCVL | ||
| Defuel/Flush Valves (Section 4-4.2.3) | DFFCVL | ||
| Issue Venturi (Section 4-4.2.4) | ISVTR | ||
| Return Venturi (Section 4-4.2.5) | RTVTR | ||
| Back Pressure Control Valves (Section 4-4.2.6) | BPCVL | ||
| Pressure Control Valves (Section 4-4.2.7) | PCVL | ||
| Hydrant Control Valves (Section 4-4.2.8) | HCVL | ||
| Emergency Shut-off Valves (Section 4-4.2.9) | ESOVL | ||
| Pantograph Control Valves (Section 4-5.2.12) | PTCVL | ||
| Pantograph Pressure Control Valves (Section 4-5.2.13) | PTPCVL | ||
| Overfill Valve for Product Recovery Tanks (Section 4-8.1) | OVLPRT | ||
| Plug Valves - Lubricated (Section 6-6.2.1) | PLVL | ||
| Plug Valves - Non-lubricated (Section 6-6.2.2) | NPLVL | ||
| Gate Valves (Section 6-6.2.3) | GTVL | ||
| Ball Valves (Section 6-6.2.4) | BLVL | ||
| Double Block and Bleed Valves (Section 6-6.2.5) | DBBVL | ||
| Butterfly Valves (Section 6-6.2.6) | BFVL | ||
| Globe Valves (Section 6-6.2.7) | GLVL | ||
| Check Valves (Section 6-6.2.8) | CKVL | ||
| Line Blanks, Ring Spacers, and Spectacle Blinds (Section 6-6.2.9) | BLIND | ||
| Manual Valve Gear Operators (Section 6-6.2.10) | MVLGO | ||
| Fire Valves (Section 6-6.4.1) | FRVL | ||
| Fusible Link Butterfly Valves (Section 6-6.4.2) | FLBFVL | ||
| Truck Fill Valves (Section 6-6.5.1) | TFVL | ||
| Motor Operators (Section 6-6.6) | MTROP | ||
| External High Level Shutoff Valves (HLSO) (Section 8-9.6.1) | EHLSVL | ||
| Internal HLSO Valves (Section 8-9.6.2) | IHLSVL | ||
| Waste | Oil/Water Separators (Section 11-5) | OWS |
&"Times New Roman,Bold"&14APPENDIX F - Facility Maintenance Plan of 4
Versions and Notes
| Version | Date | Description of changes |
| v2.0 | 8/18/21 | Updated Task Matrix to meet UFC 3-460-03 Change 1 , 29 April 2021 |
| Updated Component Acronym Tab to meet UFC 3-460-03 Change 1 , 29 April 2021 | ||
| v2.1 | 4/20/22 | Task Matrix Tab - Deleted all services facility # columns and combined into one. Renamed "Real Property Facility #" |
| Task Matrix Tab - Added "RPUID" to Real Property Unique Identifier column | ||
| Task Matrix Tab - Added "Real Property" to Facility Name | ||
| Task Matrix Tab - Added column for "Base Asset ID" | ||
| Task Matrix Tab - Added "Additional" and "RM" to Manufacturer Requirements | ||
| Task Matrix Tab - Changed Comment note for Filter Separator | ||
| Task Matrix Tab - Changed Note #3 To add "Base Asset ID if used by site shall be cross referenced with CUID appropriately." | ||
| Task Matrix Tab - Changed note #7 under instructions for Task Matrix to clarify this column | ||
| Task Matrix Tab - Changed note #8 under instructions for Task Matrix to clarify this column | ||
| Added new tab for RM schedule to be included | ||
| Added new Tab for Filter Separator/Pre-Filter Schedule with instructions | ||
| Administrative Tab - changed Installation to Site and added Site Code to comply with new requirements as the three letter DLA site code is obsolete | ||
| General Facility Description - Changed the Instructions | ||
| Reversed columns 'Base Asset ID' and 'CUID' to match RM report for all tabs | ||
| Added FMP version to footer | ||
| v2.2 | 10/31/22 | Administrative Tab - Added rows for POC Name for all |
| Administrative Tab - Added RPSUID in cell B2 | ||
| General Facility Description Tab - Added "fuel type" | ||
| Communication Plan Tab - added "coordination for access" | ||
| Safety Tab - Changed instructions to read "Site Specific Addendum and Activity Hazard Analysis, which are Attachments to the APP, specific to activities or tasks related to recurring maintenance for this site." | ||
| Changed footer for tabs to FMP v2.2 | ||
| Task Matrix and FS/PF Schedule added not to print as 11x17. Also changed in page layout. |
image1.jpeg image2.jpeg image3.jpeg image4.jpeg image5.jpeg
File details come from the government source that posted it. Updated .