Powerride1_DS.pdf

PDF 6 MB Posted

Attached to
Z1NZ--UPS Maintenance - SF
Solicitation number
36C26324Q0373
Issued by

About this file

This solicitation seeks uninterruptible power source preventive maintenance services. The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 23 is requesting quotes for preventive maintenance of UPS equipment at the VA Sioux Falls Health Care System from May 1, 2024 to April 30, 2025 with four additional one-year option periods. The NAICS code is 811310 with a $12.5 million size standard. Quotes are due by March 28, 2024 and the procurement is set aside for small businesses. The solicitation includes contract line items, product descriptions, response dates, and refers to FAR provisions and clauses incorporated into the solicitation document.

View the file

Other files

Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PowerRide I Single Phase, 2.1 to 17kW o�ce buildings • factories • warehouses hospitals • hotels • motels • schools • universities shopping centers • airports • casinos • supermarkets military installations • apartment buildings train and bus terminals • houses of worship

HID, Incandescent, Fluorescent, LED 120, 208, 240, 277, or 480 Volts Listed to UL924 Lighting and UL1778 UPS by CSA

PowerRide I on-line // standy-by/fast transfer

The PowerRide I incorporates state of the art technology with PWM (Pulse Width Modulated), double conversion design for emergency lighting applications. When utility power fails, the Inverter provides uninterrupted output power to the emergency lighting circuits in compliance with UL924 Life Safety Code for 90 minutes of egress illumination.

STANDARD FEATURES

Back-lit LCD Display for monitoring System pre-wired for optional Global Monitoring System (GMS) Battery Breaker Inverter Test Switch Generator Compatible with Automatic Governor (Slew Rate 0.2Hz/sec.)

Battery Management Software High Frequency PWM with Digital Signal Processing Technology Built-in Input Power Factor Correction key features:

Fast Transfer, Standby, and Double Conversion “no-break” online system are available E�ciency: 94% Online / 98% Standby/Fast Transfer (Typical) Automatic monthly and annual self-testing Latest technology microprocessor controlled electronics with PWM (Pulse Width Modulated) design for true Sine Wave output Continuous self-diagnostic and self-testing system

LCD backlit panel for comprehensive monitoring of power line conditions and inverter status Sealed maintenance-free lead calcium batteries with 10 year prorated warranty Battery Exerciser Single Cabinet design for ease of installation, convenient front access 2 Year Warranty*

LOS ANGELES, CA

Tel: 800-786-6915 www.perfectpowersystems.com

*Second Year, months 13 to 24 only valid with factory performed preventive maintenance

710-DS-11-20

PowerRide I

KW Input/Output Voltages

MODEL

NUMBERS

DC

Volts

Cabinet Size (W x H x D )

Wgts (lbs)

2.1

120/120 208/208 240/240 277/277 480/277

PD3.0A0100N1-VA

PD3.0B1300N1-VA

PD3.0D0400N1-VA

PD3.0R2500N1-VA 96 39” x 68” x 18” 896

3.0 96 39” x 68” x 18” 1066

5.0 120 39” x 68” x 18” 1284

6.0 144 39” x 68” x 18” 1284

7.5 120 51” x 70” x 30.5” 1074

8.0 192 39” x 68” x 18” 1464

10 192 51” x 70” x 30.5” 2870

12.5 192 51” x 70” x 30.5” 3777

15.0 240 51” x 70” x 30.5” 4512

17.0 240 51” x 70” x 30.5” 4512

TECHNICAL SPECIFICATIONS

* Input Voltage “X“: A = 120, B = 208, D = 240, R = 277, H = 480 VAC

* Input Voltage “Y“: R = 277 or H = 480 VAC

* Output Voltage “5800” = 120/240, or 208, or 277 VAC

* Output Voltage “5899” = 277 & 480 VAC

Consult factory for 120V and other voltages

All units are 90 minutes battery back-up time at full load.

For other back-up times (up to 6 hours), consult factory

Power Rating: 2.1, 3, 5, 6, 7.5, 8, 10, 12.5, 15 & 17 kW Input Voltage:

Output Voltage: 120, 208, 240, 277, or 480 VAC Output Frequency (Inverter Operation): 60Hz +0.5Hz.

Voltage Regulation: +3% Typical Output Wave Form: Sine-wave Optional Input Protection: Input Circuit Breaker provided protection to the unit, load, and personnel and is rated at (10 KAIC) standard, higher interruption up to 65 (KAIC) optional.

Output Protection: Internal Electronic overload protection. Circuit breaker provides inherent over-load protection. Factory selectable voltage 120, 208, 240, 277, or 480 for input or output voltages. If input is different from output or output different from input, an internally mounted transformer is required.

Surge Protection: The inverter will protect itself and the load against surge as defined in ANSI/IEEE C62.45 category A and B.

Noise Isolation: -120 dB. Common-Mode.; 60 dB. Transverse-Mode Isolation: Output is completely isolated from input and with multi voltages

E�ciency: 98% standby - fast transfer / 94% online Power Factor: Unity Crest Factor: 3:1 Battery : Sealed maintenance free (SMF).

Battery Management System: Utilizes a microprocessor technology to monitor the batteries critical levels and apply charging cycles in a method to substantially increase battery life.

Housing: Free standing NEMA 1 Enclosure powder coated paint Front access only Multiple conduit entries. Refer to chart for dimensions.

Recharge Time: Conforms to UL924

ENVIRONMENTAL:

Humidity: 0-95% RH w/no condensation Operating temperature:

UPS: 0˚ to 40˚C. (32˚ to 104˚F) BATTERY: 20˚ to 25˚C (68˚ to 77˚F)

Storage temperature: -20˚ to 70˚C. (-4 to 158˚F) Safety Agencies: CSA Listed to UL 924, UL 924A, UL1778

OPTIONS

Optional Global Monitoring System (GMS) Provide SNMP, MIB to monitor & log UPS status Auto-sense 10M/100M Fast Ethernet Manage & configure via Telnet, Web Browser or NMS Support TCP/IP, UDP, SNMP, Telnet, SNTP, PPP, HTTP, SMTP Protocol Sending both of SNMP TRAP and Email for events notifi-cation.

Auto email daily Battery Backup history report (config-urable) Basic NetAgent: LAN or WIFI Advance NetAgent: LAN, WIFI, Dial-up Modem, or GPRS Modem

Consult factory for more features and choices of remote communication.

Speci�cations are subject to change without prior noti�cation.

3.5 120 39” x 68” x 18” 1171

Secondary Auxiliary Circuit Breakers (up to 16 or 24 one-pole OCB’s): Normally On, Normally Off, Normally Off w/ Delay, Trip Alarm Dry Contact: With Single Common, N/O, N/C contacts with individual isolated Common Remote Status Panel Unit with Audio Alarm and Silence Switch Local Audio Alarm with Silence Switch Make Before Break Internal Maintenance Bypass Switch External Maintenance Bypass Switch (wrap around type) Main Input and/or Output Circuit Breaker (with custom KAIC) Input Transient Voltage Surge Suppressor (TVSS) Battery Thermal Runaway Certified Zone 4 Seismic Bracket: Adds approx. 4” of additional floor space to each side of cabinet Extended Warranty and Service Plans Long Life Battery: Check with factory for number of cabinets Battery Monitoring System Event logging Monitoring via RS232 and RS485

710-DS-11-20

2.1 - 5KW, 6KW; 120, 208, 240, 277, or 480 VAC (-15% to +10%)

7.5 - 17KW; 208, 240, 277, or 480 VAC (-15% to +10%)

48” H Optional

48” H Optional

X / 208, 277, 120/240 Y / 277 & 480

PD3.0H2500N1-VA

PD3.0X5800T1-VA

PD3.0Y5899T1-VA

120/120 208/208 240/240 277/277 480/277

PD3.0A0100N1

PD3.0B1300NI

PD3.0D0400NI

PD3.0R2500N1

X / 208, 277, 120/240 Y / 277 & 480

PD3.0H2500N1

PD3.0X5800T1

PD3.0Y5899T1

120/120 208/208 240/240 277/277 480/277

PD5.0A0100N1-VA

PD5.0B1300N1-VA

PD5.0D0400N1-VA

PD5.0R2500N1-VA

X / 208, 277, 120/240 Y / 277 & 480

PD5.0H2500N1-VA

PD5.0X5800T1-VA

PD5.0Y5899T1-VA

120/120 208/208 240/240 277/277 480/277

PD5.0A0100N1

PD5.0B1300N1

PD5.0D0400N1

PD5.0R2500N1

X / 208, 277, 120/240 Y / 277 & 480

PD5.0H2500N1

PD5.0X5800T1

PD5.0Y5899T1

120/120 208/208 240/240 277/277 480/277

PD6.0A0100N1

PD6.0B1300N1

PD6.0D0400N1

PD6.0R2500N1

X / 208, 277, 120/240 Y / 277 & 480

PD6.0H2500N1

PD6.0X5800T1

PD6.0Y5899T1

208/208 240/240 277/277 480/277

PD7.5B1300N1

PD7.5D0400N1

PD7.5R2500N1

X / 208, 277, 120/240 Y / 277 & 480

PD7.5H2500N1

PD7.5X5800T1

PD7.5Y5899T1

208/208 240/240 277/277 480/277

PD8.0B1300N1

PD8.0D0400N1

PD8.0R2500N1

X / 208, 277, 120/240 Y / 277 & 480

PD8.0H2500N1

PD8.0X5800T1

PD8.0Y5899T1

208/208 240/240 277/277 480/277

PD010B1300N1

PD010D0400N1

PD010R2500N1

X / 208, 277, 120/240 Y / 277 & 480

PD010H2500N1

PD010X5800T1

PD010Y5899T1

208/208 240/240 277/277 480/277

PD012B1300N1

PD012D0400N1

PD012R2500N1

X / 208, 277, 120/240 Y / 277 & 480

PD012H2500N1

PD012X5800T1

PD012Y5899T1

208/208 240/240 277/277 480/277

PD015B1300N1

PD015D0400N1

PD015R2500N1

X / 208, 277, 120/240 Y / 277 & 480

PD015H2500N1

PD015X5800T1

PD015Y5899T1

208/208 240/240 277/277 480/277

PD017B1300N1

PD017D0400N1

PD017R2500N1

X / 208, 277, 120/240 Y / 277 & 480

PD017H2500N1

PD017X5800T1

PD017Y5899T1

File details come from the government source that posted it. Updated .