About this file
This is a technical drawing specification document for the Middle School Roof Replacement project in Michigan, detailing the construction requirements for a built-up roofing (BUR) pitch pocket assembly. The drawing (DWG No. 33) provides comprehensive specifications for installing a hot/cold pitch pocket with grout, including the attachment of wood nailers to the roof deck using two rows of staggered fasteners spaced 24 inches on center. The assembly requires specified insulation, gravel surfacing set in asphalt cement with mechanical fasteners spaced 3 inches on center in a staggered pattern, and a metal pitch pocket with a minimum 4-inch height. The specification calls for priming of the metal flange before application of two-ply top-off material with Tremco sealant, inclusion of membrane under the prime metal flange to prevent grout leakage, and filling the pitch pocket to 1 inch from the top with non-shrink grout and a metal hood.
The drawing is presented at a scale of "Not to Scale" (NTS) and includes detailed technical specifications for materials and installation methods essential to the roof replacement project. No information regarding pricing terms, bid deadlines, site visit requirements, bidder conferences, contract award dates, contract terms, set-asides, or funding sources is contained within this technical specification document. The drawing serves as a construction standard to ensure proper installation of roof penetration details during the project execution phase.
View the file
Other files
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DWG NO. 33
BUILT UP ROOFING
HOT/COLD PITCH POCKET WITH GROUT
WOOD NAILER SECURED
SPECIFIED BUR
SPECIFIED INSULATION
ROOF DECK
TO DECK w/ APPROPRIATE
FASTENERS, 2 ROWS
STAGGERED EACH
ROW 24'' O.C. AS SPECIFIED
GRAVEL SURFACING
FLANGE SET IN SPECIFIED
ASPHALT CEMENT, MECHANICALLY
FASTENED 3'' O.C., STAGGERED
PRIME METAL FLANGE BEFORE
STRIPPING
TWO-PLY
TOP OFF w/
TREMCO SEALANT
METAL PITCH POCKET
MINIMUM 4" HEIGHT
SPECIFIED DRAWBAND
AND SEALANT
STRIPPING
FILL 1'' FROM TOP
w/ NON-SHRINK GROUT w/ METAL HOOD
MEMBRANE UNDER
PRIME METAL FLANGE
PITCH POCKET AND
PRIME INTERIOR OF
SEAL PIPE BASE TO
PREVENT GROUT
LEAKAGE INTO BUILDING
SHEET TITLE:
DRAWING No.:
SCALE:
NTS
| Sheets and Views |
| Model |
File details come from the government source that posted it. Updated .