Flashing-for-Non-Wall-Supported (1).pdf
PDF 144 KB Posted
- Attached to
- Middle School Roof Replacement
- Solicitation number
- RFP MASO 270000000153 1
- Issued by
- Genesee County, Edmore Village, Michigan
About this file
This is a technical architectural drawing (DWG No. 11) specification for built-up roof hot/cold wall flashing design related to a Middle School Roof Replacement project in Michigan. The drawing provides detailed construction specifications for non-wall-supported deck flashing systems utilizing a specified built-up roof (BUR) membrane with two-ply fasteners spaced 8 inches on center. Key components include one-piece counterflashing, specified sealant application, roof deck insulation, gravel surfacing installed into reglet and secured with lead wedges at 8-inch intervals, flexible vapor retarder as insulation retainer, wood nailer secured to deck with fasteners in two staggered rows spaced 24 inches on center, stripping specified base flashing, and wood cant nailed to sheet blocking in two rows spaced 12 inches on center in a staggered pattern. The drawing specifies a minimum clearance of 4 inches and is drawn to a not-to-scale (NTS) notation.
The specifications indicate standard roofing construction practices and material requirements for the flashing assembly, with compressible insulation and appropriate fastening protocols detailed throughout the design. No specific pricing terms, set-asides, contract duration, funding sources, or award information is contained within this technical drawing document.
View the file
Other files
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DWG NO. 11
BUILT-UP ROOF
HOT/COLD WALL FLASHING FOR
NON-WALL-SUPPORTED DECK
SPECIFIED BUR MEMBRANE
TWO-PLY
FASTENERS 8'' O.C.
ONE PIECE COUNTERFLASHING
SPECIFIED SEALANT
SPECIFIED INSULATION
ROOF DECK AS SPECIFIED
GRAVEL SURFACING
INSTALLED INTO REGLET AND
SECURED w/ LEAD WEDGES 8'' O.C.
FLEXIBLE VAPOR RETARDER
TO SERVE AS INSULATION
RETAINER
COMPRESSIBLE INSULATION
WOOD NAILER SECURED TO
DECK w/ APPROPRIATE
FASTENERS, 2 ROWS
STAGGERED EACH ROW
24'' O.C.
STRIPPING
SPECIFIED BASE FLASHING
ROW 12'' O.C.
STAGGERED EACH
BLOCKING, 2 ROWS
NAIL WOOD CANT TO
SHEET TITLE:
DRAWING No.:
SCALE:
NTS
AutoCAD SHX Text
4'' MIN.
| Sheets and Views |