Flashing-for-Non-Wall-Supported (1).pdf

PDF 144 KB Posted

Attached to
Middle School Roof Replacement
Solicitation number
RFP MASO 270000000153 1
Issued by
Genesee County, Edmore Village, Michigan

About this file

This is a technical architectural drawing (DWG No. 11) specification for built-up roof hot/cold wall flashing design related to a Middle School Roof Replacement project in Michigan. The drawing provides detailed construction specifications for non-wall-supported deck flashing systems utilizing a specified built-up roof (BUR) membrane with two-ply fasteners spaced 8 inches on center. Key components include one-piece counterflashing, specified sealant application, roof deck insulation, gravel surfacing installed into reglet and secured with lead wedges at 8-inch intervals, flexible vapor retarder as insulation retainer, wood nailer secured to deck with fasteners in two staggered rows spaced 24 inches on center, stripping specified base flashing, and wood cant nailed to sheet blocking in two rows spaced 12 inches on center in a staggered pattern. The drawing specifies a minimum clearance of 4 inches and is drawn to a not-to-scale (NTS) notation.

The specifications indicate standard roofing construction practices and material requirements for the flashing assembly, with compressible insulation and appropriate fastening protocols detailed throughout the design. No specific pricing terms, set-asides, contract duration, funding sources, or award information is contained within this technical drawing document.

View the file

Other files

Show all 19

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DWG NO. 11

BUILT-UP ROOF

HOT/COLD WALL FLASHING FOR

NON-WALL-SUPPORTED DECK

SPECIFIED BUR MEMBRANE

TWO-PLY

FASTENERS 8'' O.C.

ONE PIECE COUNTERFLASHING

SPECIFIED SEALANT

SPECIFIED INSULATION

ROOF DECK AS SPECIFIED

GRAVEL SURFACING

INSTALLED INTO REGLET AND

SECURED w/ LEAD WEDGES 8'' O.C.

FLEXIBLE VAPOR RETARDER

TO SERVE AS INSULATION

RETAINER

COMPRESSIBLE INSULATION

WOOD NAILER SECURED TO

DECK w/ APPROPRIATE

FASTENERS, 2 ROWS

STAGGERED EACH ROW

24'' O.C.

STRIPPING

SPECIFIED BASE FLASHING

ROW 12'' O.C.

STAGGERED EACH

BLOCKING, 2 ROWS

NAIL WOOD CANT TO

SHEET TITLE:

DRAWING No.:

SCALE:

NTS

AutoCAD SHX Text

4'' MIN.

Sheets and Views
Model

File details come from the government source that posted it. Updated .