Hot-Stack-Penetration.pdf

PDF 124 KB Posted

Attached to
Middle School Roof Replacement
Solicitation number
RFP MASO 270000000153 1
Issued by
Genesee County, Edmore Village, Michigan

About this file

This is a technical drawing specification document for a hot-stack roof penetration detail, applicable to the Middle School Roof Replacement project in Michigan. The drawing (DWG NO. 07) provides detailed construction specifications for installing a penetration through a built-up roofing (BUR) system where a hot stack pipe passes through the roof assembly. The specification includes requirements for a sheet-metal sleeve, rain collar, and insulated metal liner, with critical installation notes regarding temperature thresholds and material preparation. Key specifications include priming all metal surfaces that contact adhesive, welding or soldering the rain collar to the pipe when service temperatures exceed 400 degrees Fahrenheit, and maintaining appropriate clearance between the hot pipe and insulated metal liner based on material temperature. The assembly incorporates multiple layers including a two-ply stripping with a minimum 4-inch flange set in asphalt cement and mechanically fastened at 3-inch centers, stainless steel clamping ring, treated wood blocking, and specified insulation and cover board materials.

The drawing specifies an 8-inch minimum dimension and 3- to 4-inch overlap for the flashing collar, with perimeter mastic sealing required at the existing insulated metal liner connection. The detail requires coordination between roofing, sheet metal, and mechanical trades to ensure proper installation of the hot stack penetration. No specific pricing, quantities, bidding procedures, or contract terms are addressed within this technical drawing document itself, as it serves as a design and construction specification for implementation within the broader Middle School Roof Replacement project scope.

View the file

Other files

Show all 19

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DWG NO. 07

NOTES

1. PRIME ALL METAL SURFACES THAT WILL COME INTO CONTACT WITH THE SPECIFIED ADHESIVE.

2. WHEN HOT STACK SERVICE TEMPERATURE EXCEEDS 400 DEGREES, WELD OR SOLDER RAIN COLLAR TO

PIPE IN LIEU OF INSTALLING SEALANT.

3. THE CLEARANCE REQUIRED BETWEEN THE HOT PIPE AND INSULATED METAL LINER WILL DEPEND ON THE

TEMPERATURE OF THE MATERIAL HANDLED BY THE STACK.

BUILT-UP ROOFING HOT/COLD

HOT STACK PENETRATION

SHEET-METAL SLEEVE

APPROPRIATE HIGH TEMPERATURE SEALANT

(SEE NOTE #2 BELOW)

SHEET-METAL RAIN COLLAR OVERLAPPING

FLASHING COLLAR BY 3" TO 4"

CLAMPING RING

STAINLESS STEEL

TREATED WOOD BLOCKING

ROOF DECK

SPECIFIED COVER BOARD

SPECIFIED INSULATION

SPECIFIED BUR MEMBRANE

TWO-PLY STRIPPING

4" MIN. FLANGE SET IN ASPHALT CEMENT

AND MECHANICALLY FASTENED 3" O.C.

BATTEN INSULATION

PERIMETER

MASTIC SEAL AT

EXISTING INSULATED

METAL LINER (SEE NOTE #3 BELOW)

HOT STACK

SHEET TITLE:

DRAWING No.:

SCALE:

NTS

AutoCAD SHX Text

8" MIN.

Sheets and Views
Model