About this file

This is a technical construction drawing specification for the Middle School Roof Replacement project in Michigan, detailing the installation requirements for piping penetrations through a built-up roofing (BUR) system. The drawing provides comprehensive guidance on securing hot and cold piping through the roof deck, including specifications for wood nailers, insulation installation with staggered fasteners spaced 24 inches on center, two-ply stripping flanges set in asphalt cement and mechanically fastened at 3-inch intervals, and proper sloping of pipes to direct water away from the hood. The detail includes requirements for sheet metal collar seals, hood design with cross breaks or slopes for drainage, insulation of interior metal work in cold climates, and metal screw seal closures, all designed to maintain the integrity of the roof membrane while accommodating necessary mechanical penetrations.

The specification emphasizes weatherproofing and durability through multiple seal layers, including asphalt cement sealing of the membrane and proper priming of metal flanges before stripping application. Fasteners are positioned at 8-inch intervals for the hood and additional closure details are provided to ensure complete water management around the piping penetrations. This drawing is scaled as "Not to Scale" (NTS) and represents a standard roofing construction detail intended to guide contractors in proper installation techniques that meet the project's technical and performance requirements.

View the file

Other files

Show all 19

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DWG NO. 18

BUILT UP ROOFING

HOT/COLD PIPING THROUGH ROOF DECK

WOOD NAILER SECURED

SPECIFIED BUR

INSULATION

ROOF DECK

TO DECK w/ APPROPRIATE

FASTENERS, 2 ROWS

STAGGERED EACH

ROW 24'' O.C.

AS SPECIFIED

GRAVEL SURFACING

TWO-PLY STRIPPING

FLANGE SET IN SPECIFIED

ASPHALT CEMENT,

MECHANICALLY FASTENED

3'' O.C., PRIME METAL

FLANGE BEFORE STRIPPING

SLOPE PIPES DOWN

AND AWAY FROM

HOOD

FASTENERS 8'' O.C.

SHEET METAL

COLLAR

SEAL

INSULATE INSIDE OF

METAL WORK IN COLD

CLIMATES

SHEET METAL HOOD

CROSS BREAK

OR SLOPE FOR

DRAINAGE

METAL SCREW

SEAL

CLOSURE DETAIL

ASPHALT CEMENT

SEAL

MEMBRANE

SHEET TITLE:

DRAWING No.:

SCALE:

NTS