This document is an Item Description for an Office Trailer request from the Department of the Air Force's Oklahoma City Air Logistics Complex (OC-ALC) at Tinker Air Force Base. The 76 PMXG unit requires a single office trailer with specific detailed specifications, including maximum dimensions of 65 feet x 30 feet, comprehensive plumbing requirements (two bathrooms and a kitchenette with hot and cold running water), and extensive electrical specifications.
The trailer must have four separate office rooms, a 100-amp 240-volt power supply, and precise electrical outlet configurations for various areas including offices, common areas, kitchen, and restrooms. Additional requirements include HVAC, lighting, ventilation, safety features like smoke alarms, climate control to withstand all four seasons in Oklahoma, and a 7-day on-site installation setup. The electrical layout is particularly specific, with designated outlet placements and quantities for each area of the trailer to ensure functional workspace and appliance support.
View the file
Other files
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DEPARTMENT OF THE AIR FORCE
OKLAHOMA CITY AIR LOGISTICS COMPLEX (OC-ALC)
TINKER AIR FORCE BASE OKLAHOMA
Item Description
Office Trailer
P26-010
76 PMXG is requesting an Office Trailer. This requirement must have the following specifications:
One (1) Office Trailer Specifications:
Requirements:
• Dimensions: Maximum 65 feet x 30 feet
• Plumbing:
• Two bathrooms with hot and cold running water at sinks, plumbed into existing sanitary sewer.
• Kitchenette equipped with sink providing hot and cold running water, plumbed into existing sanitary sewer.
• Electrical:
• 100-amp 240-volt power supply for the trailer.
• Four separate office rooms (two at each end of the trailer).
• Each office room to have a minimum of four electrical outlets.
• Larger offices shall have 6 outlets with 2 outlets on longer walls
• The common area shall have a minimum of 7 electrical outlets with 3 outlets on the south wall (walls with entry doors), 2 outlets on the eat wall, and 2 outlets on the west wall of the common area
• The kitchen shall have a minimum of 6 electrical outlets with 2 on the west wall, 3 on north wall, and 1 on east wall to supply all appliances.
• The restrooms shall have 1 electrical outlet each
• The kitchenet shall have an adequate exhaust fan
• Access: Include steps to access the unit, if required.
• HVAC, Lighting, & Ventilation: Required for all areas.
• Safety: Smoke alarms must be adequately installed per individual rooms.
• Climate Control: Must maintain temperature for proper operation during all four seasons at Tinker AFB, OK.
• Installation: 7-Day On-Site Setup